ALTUS ALTUS ALTUS Altus+ Classic Center Open Lens 2x2 Technical Specifications Classic Altus+ Classic provides comfortable, even, diffuse light for use in private offices, ALTUS open office areas, upscale retail applications, public circulation areas and CLASSIC classrooms. ALTUS Classic 1 2 • Minimal Housing depth allows for easy installation into shallow plenums. 3 3/4” as iandcsecure • Injection molded LightC Trapslprevent lights leaks Diffuser to fixture. High performance perforated metal Diffuser combined with thin inlay produces high efficiencies. 23•7/8” 23 7/8” ALTUS 3 1 2 3 HIGH ACC OP 3T5 CS PERFORMANCE CONSTRUCTION 3.75"" deep housing allows for fixture installation in shallow plenums. Gauge compliant End 3 3/4”Caps interlock into channelHI to GH form sturdy fixture Housing. Two KOs per end and large access plate in Channel PERF ORMANC E simplify wiring. End Caps include integral grid locking feature and four auxiliary mounting points. Die formed post painted HIGH reflectors are easily removable for room side ballast access. PERFORMANCE Post painted open perforated steel Diffuser backed 3 3/4”with high transmission overlay is held in place with injection 23 7/8” mounting bracket that prevent light leaks and allow molded diffuser to swing down." ACC OL 3T5 CS OPTICAL SYSTEM Frosted acrylic extruded prismatic lens diffuser for exceptional fixture efficiencies. 90%+ reflective, 3 3/4” to post painted reflectors light evenly and contribute efficiency and pleasing contrast. ALTUS 3 3/4” 23 7/8” ACC OP 2T5 CS BALLASTS All supplied fluorescent ballasts are Class P, high power factor, sound rated A, thermally protected, auto resetting, CEE / NEMA Premium compliant unless 23 7/8” All ballasts are fitted with NEC/CEC otherwise specified. compliant ballast disconnect. Numerous ballast factor options available for T8 CS & T5. See "Ballast Technical Sheet" ACC OP 2TT5 for more information. ALTUS ALTUS CEILING COMPATIBILITY Altus+ fixtures are compatible with "G" type239/16" 7/8” wide & 15/16" Tee lay-in Grid styles. Also compatible with type "ST" Screw Slots Tees please ACC OL 2T5 CS see illustration. Integral grid lock in End Cap secures fixture. Use tie wire secured and GCK22 or GCK24 frame kits for sheet rock ceiling applications. Contact factory for Surface Mounting. 23 7/8” CERTIFICATION All units are built to UL 1598 standards and are labeled C-UL-US Damp location certification standard.ACC Emergency fixtures OL 2TT5 CS are labeled UL924. FINISH All exposed installed surfaces are treated with a multistage, iron phosphate pretreatment and post3 3/4” painted with tough, matte white, polyester, powder coat paint with 23 7/8” a minimum of 90% reflectivity. 23 7/8” ELECTRICAL Biax fixtures use 2G11 base lamp holders. T8 ACD & OPT52T5 CS use rotolock lamp holders for securing lamps fixtures when fixture is installed or in transit. ACD OP 2T5 CS BG 3 3/4” SIZE 22 = 2’ X 2’ DIFFUSER OL = Open Lens 23 7/8” 23T7/8” 5 T5 T T T 8 T8 L ED T 2TT5 T3T8 CS ACCOP OL ACC CS T12 3 3/4” 23 7/8” T 5 T5 T T ACC OL 3T5 CS T 8 3T8 3/4” L ED T T T12 23 7/8” 3 3/4” T 5 T5 T T 23T7/8” 8 T8 ACD OP 2T8 CS L ED T T T12 ACC OL 2TT5 CS MADE IN THE UNITED STATES 3 3/4” 3 3/4” LAMPS 2 3 3 3/4” 23 7/8” WATTAGE 17T8 = 17W T8 24” 14T5 =EL 14W T5 CS 22” AHPC 3T8 24T5HO = 24W T5HO 22” 40TT5 = 40W TT T5 24” 50TT5 = 50W TT T5 24” 55TT5 = 55W TT T5 24” *TT Lamps NOT available in 3 lamp configuration *Nominal. See performance table for actual power consumption. 23 7/8” EL 232 T8 3/4” 333/4” ACD OP 2T5 CS AHPC EL 3T5 CS 7/8” ACC OP 3T5 CS ACD OP 2TT5 CS 3 3/4” OPTIONS AR = Air Return BP = Bulk Pack, Palletized 35K = 3500˚K Lamp Installed 41K = 4100˚K Lamp Installed ELS1 = Emergency Lighting (T8 500 lm, T5 700 lm) ELS2 = Emergency Lighting (T8 700 lm,3T5 700 lm) 3/4” ELS3 = Emergency Lighting (T8 1400 11 7/8” lm, T5 1400 lm) FL4 = Whipped 3/8 6' Flex 2 #18s FL5 = Whipped 3/8 6' Flex 3 #18s FB = Fast-Blow Fusing ACC 14 OP 132 T8 SB = Slow-Blow Fusing (T5 only) M/S = Labor saving Master/Satellite DBG = Debris Guard 23 7/8” 23 7/8” 23 7/8” AHPD 2T5 CS 3 3/4” 23 7/8” 3 3/4” SERIES ACC = Altus + Classic Center AHPC EL 2 T5 CS SACC = Surface Altus + Classic Center ACC OP 3T8 CS 3 3/4” Altus+ Classic Center 2x2 Open Lens 23 7/8” Pr ojec t C at alog N um ber Ty pe D at e 23 7/8” ACCESSORIES GCK22 = Sheetrock/Plaster Grid Kit, 2x2 3 3/4” BALLAST E = Electronic Instant Start PSL = T8 only, Low BF .71* PSN = *T8 only, Normal BF .80* PSH = *T8 only, High BF 1.15* 3 3/4” D = Dimming (Customer Specified) HE = Electronic T5HO only HPL = T8 only, Low BF .77* HPN = T8 only, Normal BF .87* HPH = T8 only, High BF 1.18* CS = Customer Supplied 3 3/4” B9 = Customer Specified 3 3/4” * For exact BF see CEE listing for ballast qualification. 23 7/8” 23 7/8” AHPD LED CS AHPC EL 3T5 CS 3 3/4” 23 7/8” 23 7/8” AHPD EL 2TT5 CS AHPD 2T5 CS 3 3/4” 3 3/4” 11 7/8” 3 3/4” 11 7/8” 23 7/8” AHPD EL 2TT5 CS AHPCLED 14 EL 2141 AHPC 14 EL 228 T5 3 3/4” 11 7/8” AHPC EL 2 T5 CS AHPD 2T8 CS 3 3/4” 3 3/4” 23 7/8” 23 7/8” VOLTAGE SWITCHING U1 = 120-277V For 2 lamp units: 347 = 347V AHPC EL1 2T8 = One 2-lamp ballast ACD OP 2TT5 CS CS 480 = 480V 11 = Two 1-lamp ballasts For 3 lamp units: 21 = One 2-lamp ballast, One 1-lamp ballast 23 7/8” 3 = One 3-lamp ballast 3 3/4” 11 7/8” 11 7/8” ACC 14 OP 132 T5 3 3/4” 11 7/8” 11 7/8” "AR" not available with "DBG". "DBG" not available with "AR". ACC 14 OP 232 T8 FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS CHANGE WITHOUT NOTICE. AHPC 14SUBJECT EL 228TO T5 (800) 10302014 REV 3.0 523-3602 • www.simkar.com AHPC 14 EL 232 T8 3 3/4” ACC 14 OP 132 T8 3 3/4” 7⁄8” KO TYP 10¼” 4” Altus+33⁄Classic Center Open Lens 2x2 2½” Technical Specifications 1½” Ceiling Compatibility 20½” Dimensions 15/16" T Grid 9/16" T Grid 9/16" Screw Slot 7⁄8” KO TYP 10¼” 33⁄4” 2½” 1½” 9/16” 15/16” 20½” 237⁄8” 1/8” 9/16” Plaster Frame Kit Plaster Frame Kit Ceiling Opening Width 237⁄8” Length 1x4 12 - 13 1/2" 48 - 49 1/2 2x2 24 - 25 1/2" 24 - 25 1/2" 2x4 24 - 25 1/2" 48 - 49 1/2 3”x4” Access Plate 2½” 25⁄16” Features Note: Surface box available. Contact factory for more information. 7⁄8” KO TYP 10¼” 33⁄4” 2½” 1½” 20½” 7⁄8” KO TYP Light Trap 10¼” 33⁄4” Debris Guard 2½” 1½” 20½” Photometric Data ACC 22 OL 2 17T8 HPN Candela Plot Coefficients of Utilization Luminaire Data Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency ACC 22 OL 2 17T8 HPN UL678957 (2) 17W T8 1375 Osram QTP 2/32T8/UNV ISN-SC 0.87 29.34 2,073 75.4% CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 90 82 75 69 63 58 53 49 45 41 38 50 90 79 69 61 54 48 43 39 34 31 28 30 90 76 64 55 48 41 36 32 28 25 22 10 90 73 60 50 43 36 31 27 24 20 18 50 84 74 65 58 51 45 41 37 33 30 27 50 30 84 72 61 53 46 40 35 31 27 24 22 10 84 70 58 49 42 36 31 27 23 20 18 50 80 71 63 56 50 44 39 36 32 29 26 30 30 80 69 60 52 45 39 34 30 27 24 21 180 10 80 67 57 48 41 35 31 27 23 20 18 150 120 ACROSS 45 ALONG 90 300 60 600 Zonal cavity method Effective floor reflectance = 20% 900 ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 LUMENS 555 908 1605 2073 1165 468 0 2073 % LAMP 20.18 33.03 58.36 75.38 42.35 17.02 0.00 75.38 % LUMINAIRE 26.77 43.82 77.42 100.00 56.18 22.58 0.00 100.00 ANGLE 45 55 65 ALONG 1682 1511 1353 45 1980 1906 1866 ACROSS 2238 2274 2383 75 85 1168 739 1831 1333 2068 1858 S/MH: 1.4 SC(ALONG): 1.2; SC(ACROSS): 1.4 FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 10302014 REV 3.0 0 Luminance Summary (Candela/M 2 ) Zonal Lumens and Percentages (800) 523-3602 • www.simkar.com 30 4713 Altus+ Classic Center Open Lens 2x2 Technical Specifications Photometric Data ACC22OL214T5 Candela Plot Coefficients of Utilization Luminaire Data Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency ACC 22OL 214T5 UL678960 (2) 14W T5 1250 Advance Centium ICN2S28-N 1.04 32.97 2,228 89.1% CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 1.06 97 89 81 74 68 62 57 53 49 45 50 1.06 93 81 72 64 56 50 45 40 37 33 30 1.06 89 76 65 56 48 42 37 33 29 26 10 1.06 86 70 59 50 42 37 32 28 24 21 50 99 87 76 68 60 53 48 43 39 35 32 50 30 99 84 72 62 54 47 41 36 32 28 25 10 99 82 68 58 49 42 36 31 27 24 21 50 95 84 74 65 58 52 46 42 38 34 31 30 30 95 81 70 61 53 46 40 36 31 28 25 180 10 95 79 66 57 49 41 36 31 27 23 21 150 120 90 225 60 450 Zonal cavity method Effective floor reflectance = 20% 675 ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 LUMENS 585 960 1706 2228 1269 523 0 2228 % LAMP 23.42 38.39 68.22 89.13 50.74 20.91 0.00 89.13 0 Luminance Summary (Candela/M 2 ) Zonal Lumens and Percentages % LUMINAIRE 26.27 43.07 76.54 100.00 56.93 23.46 0.00 100.00 ANGLE 45 55 65 ALONG 1802 1627 1465 45 2108 2053 2034 ACROSS 2372 2450 2566 75 85 1293 979 2019 1771 2400 2582 30 S/MH: 1.3 SC(ALONG): 1.2; SC(ACROSS): 1.3 Photometric Data ACC 22 OL 2 40TT5 Candela Plot Coefficients of Utilization Luminaire Data Catalog Number Lab Test# Lamp(s) Lumens per lamp Ballast Ballast Factor Input Watts Fixture Lumens Fixture Efficiency ACC 22 OL 2 40TT5 UL678963 (2) 40W TT5 3150 Ultramax GEC240MAX-A 0.9 64.56 4,649 73.8% CC Wall RCR 0 1 2 3 4 5 6 7 8 9 10 80 70 88 81 73 67 62 56 52 48 44 41 38 50 88 77 68 60 53 47 42 38 34 31 28 30 88 74 63 54 47 40 35 31 28 24 22 10 88 71 58 49 42 35 31 27 23 20 18 50 82 72 63 56 50 44 40 36 32 29 27 50 30 82 70 60 52 45 39 34 30 27 24 21 10 82 68 56 48 41 35 30 26 23 20 18 50 79 69 61 54 48 43 39 35 31 28 26 30 30 79 68 58 50 44 38 34 30 26 23 21 180 10 79 66 55 47 40 34 30 26 23 20 17 150 120 ACROSS 45 ALONG 90 500 60 1000 Zonal cavity method Effective floor reflectance = 20% 1500 0 2 Zonal Lumens and Percentages ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 LUMENS 1257 2044 3573 4649 2605 1076 0 4649 % LAMP 19.96 32.44 56.71 73.80 41.35 17.09 0.00 73.80 Luminance Summary (Candela/M ) % LUMINAIRE 27.05 43.96 76.85 100.00 56.04 23.15 0.00 100.00 ANGLE 45 55 65 ALONG 3815 3426 3080 45 4338 4150 4118 ACROSS 4846 4932 5287 75 85 2724 2025 4174 3701 4998 5714 S/MH: 1.3 SC(ALONG): 1.2; SC(ACROSS): 1.3 FOR CUSTOM OPTIONS AND ACCESSORIES, CONTACT FACTORY. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 10302014 REV 3.0 (800) 523-3602 • www.simkar.com 30