Distributed by: www.Jameco.com ✦ 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Jameco Part Number 1773654 Embedded Power for Business-Critical Continuity Rev. 09.21.06 LPT40-M Series 1 of 3 LPT40-M Series RoHS 40 Watts Total Power: Input Voltage: # of Outputs: 40 - 55 Watts 85 - 264 VAC 120 - 300VDC Triple Electrical Specifications Special Features • • • • • • • • • • • Universal input 3" x 5" footprint Less than 1U high Remote sense on main output Built-in EMI filter Low output ripple Adjustable 5V output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Input Input range Frequency Inrush current Input current Efficiency EMI Safety ground leakage current 85-264 VAC 120-300 VDC 47-440 Hz <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C 1A max. (RMS) @ 115VAC 70% typical at full load (60% for LPT41) FCC Class A conducted; CISPR 22 Class A conducted EN55022 Class A conducted; VDE 0878 PT3 Class A conducted <75 μA @ 50/60 Hz, 264 VAC input Output Safety VDE 0750/EN60601-1 (IEC601) 113769 UL UL2601 E182560 CSA CSA 22.2 No.601.1 LR109492 CE Mark (LVD) Maximum Power 40W for convection; 55W with 30CFW forced air Cross regulation Adjustment range Hold-up time Overload protection ±2% on output 1; ±5% on outputs 2, 3 -5, +10% minimum 20ms @ 40W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output LPT41: 3.6 to 4.6VDC Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Overvoltage protection Remote sense Embedded Power for Business-Critical Continuity Rev. 09.21.06 LPT40 Series 2 of 3 Environmental Specifications Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C, -20°C start up. Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Electromagnetic susceptibility: Humidity: Operating; non-condensing 5% to 95% Vibration: Storage temperature: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Ordering Information Model Number LPT42-M Output Voltage Minimum Load +5V +12V -12V 0.4A 0.2A 0A Maximum Load with Convnection cooling 4A 2A 0.5A Maximum Load with 30CFM Forced Air 5A 2.5A 0.7A LPT45-M +5V 0.4A 4A 5A +15V 0.2A 2A 2.5A -15V 0A 0.5A 0.7A 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. Peak Load1 Regulation2 Ripple P/P (PARD)3 7A 4A 1A ±2% ±5% ±5% 50mV 120mV 120mV 7A 3A 1A ±2% ±5% ±5% 50mV 150mV 150mV 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W Natural Convection Cooling 27.5W 20W 10W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C Embedded Power for Business-Critical Continuity Astec Power Mechanical Drawing 0.22" (5.6) 4.55" (115.6) 5.00" (127) M1 GND M2 SK201 3.00" (76.2) 1 2 3 4 5 6 2.55" (64.8) SK 1 3 N 1 L _ + Remote Sense Connector Voltage Adj. Pot SK 2 0.15" (4) DIA (4 places) Rev. 09.21.06 LPT40-M Series 3 of 3 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC or +1 407 241 2752 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Units 2111-2116, Level 21 Tower 1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426 For global contact, visit: 1.14" (29) www.astecpower.com technicalsupport@astec.com While every precaution has been taken to ensure accuracy and completeness in this literature, Astec Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 0.197" (5) Printed in U S A Mating Connectors Pin Assignments Connector LPT42-M LPT45-M SK1-1 SK1-3 Line Neutral Line Neutral SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 +12V +5V +5V Common Common -12V +Sense -Sense +15V +5V +5V Common Common -15V +Sense -Sense AC Input: DC Outputs: Molex 09-50-8031 (USA) 09-91-0300 (UK) PINS: 08-58-0111 Molex 09-50-8061 (USA) 09-91-0600 (UK) PINS: 08-58-0111 Emerson Network Power. The global leader in enabling business-critical continuity. Remote Sense: Molex 22-01-2025 PINS: 08-52-0114 Astec Connector Kit #70-841-006, includes all of the above AC Power 1. 2. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) DC Power 3. 4. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. Embedded Power 6. 7. Warranty: 1 year Weight: 0.5lbs/0.23kg Connectivity Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co.