I N S TA L L AT I O N G U I D E
N2-REP-3-JB-BK - KetraNet Mesh Repeater 120-277V
*Available in multiple colors. Refer to specifications sheet.
X2 INSTALLATION GUIDE
000023-01-01
PAGE 1
!
WAR N I N G
!
Shock Hazard. May result in serious injury or death.
Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with
power on voids the warranty.
Due to risk of electric shock, a licensed electrician should install this power supply unit in strict
compliance with the National Electric Code and any state or local code which may apply.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
X2 INSTALLATION GUIDE
000023-01-01
PAGE 2
TA B LE O F CO NTE NT S
Cover Page........................................................................................................
page 1
Warning.............................................................................................................
page 2
Table of Contents.............................................................................................
page 3
Product Overview............................................................................................
page 4
Included Components....................................................................................
page 5
Specifications...................................................................................................
page 5
Dimension Drawings.......................................................................................
page 6
Wiring Diagrams..............................................................................................
page 6
N2 Placement....................................................................................................
page 7
Installation..........................................................................................................
page 8
Warranty & Tech Support..............................................................................
page 12
X2 INSTALLATION GUIDE
000023-01-01
PAGE 3
PRO D U C T OV E RVI E W
Ketra’s N2 wireless repeater broadens the scope of an installation by relaying
KetraNet Mesh wireless signals. Acting as a signal booster and a repeater, the N2
ensures unbroken communication between weak wireless zones as well as over
distances greater than Ketra’s wireless range. The N2 is sized for standard wall
boxes, and its blank surface fits comfortably within Decora® and Claro wallplates
or behind blank wallplates.
N2 Mounting
Wall Plate
Screws
Mounting
Screws
Backbox
X2 INSTALLATION GUIDE
N2 Module
000023-01-01
Wall Plate
Single Gang
Mount
Wall Plate
PAGE 4
PRO D U C T OV E RVI E W
X2.D.ELV
SN: KX12345678
DC: V0216
N2 Module
Wall Plate
Mount
Single Gang
Wall Plate
X2.D.ELV
SN: KX12345678
DC: V0216
(2) #6-32 x 1/4”
Wall Plate
Mounting Screws
(2) #6-32 x 1”
N2 Mounting
Screws
Serial
Number Stickers
Wire
Nuts
S PECI FI C ATI O N S
Environmental
Ambient Operating
Temperature
Storage Temperature
Electrical
0° to 40°C
-20° to 80°C
Humidity
0-95%, Non-condensing
Certification
UL, cUL, FCC Class B, RoHS
Input Wiring
Voltage
Power Consumption
Frequency
16 AWG Flying Leads
120-277 VAC
2W
50/60 Hz
Mechanical
Weight
Housing Material
8.8oz/250kg
Flame Retardant Polymer
Wireless
Frequency
X2 INSTALLATION GUIDE
2405 - 2480 MHz
000023-01-01
PAGE 5
DI M E N S I O N D R AWI N G S
1.3
3815 S. CAPITAL OF TEXAS HWY
SUITE 100
AUSTIN, TX 78704
P: 512.872.4349
4.1
3.3
2.6
1.4
1.7
MULTI-GANG TRIM
.2
2.4
FOR REFERENCE ONLY
NOT FOR
CONSTRUCTION
DRAWING TYPE: PDD
DRAWING #: 775-000015-01
REVISION #: 01
3815 S. CAPITAL OF TEXAS HWY
SUITE 100
AUSTIN, TX 78704
P: 512.347.1100
DATE: 06/28/2016
DRAWN BY: DL, CEH
CHECKED BY: GEB
SCALE: NTS
GENERAL NOTES:
SHEET NAME
1. KETRANET MESH IS KETRA'S
WIRELESS CONTROL PROTOCOL.
2. A NODE IS A KETRANET MESH
ENABLED WIRELESS DEVICE.
RED
PROPRIETARY
~
120V
50/60 Hz
HOT/LINE
BLACK
NEUTRAL
WHITE
GROUND
GREEN
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
KETRA, INC. ANY REPRODUCTION
IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF KETRA, INC.
IS PROHIBITED.
X2 KEYPAD - PRODUCT
DOCUMENT DRAWING
3. 50 KETRANET MESH NODES MAX.
PER INSTALLATION NETWORK.
LOAD
N2
4. ALL KETRANET MESH NODES TO
BE INSTALLED WITHIN 50'-0"
RANGE OF THE NEAREST NODE.
SHEET
1
WI R I N G DIAG R AM S
N2,
REPEATER
FOR REFERENCE ONLY
NOT FOR
CONSTRUCTION
DRAWING TYPE: WD
DRAWING #:
REVISION #: 00
~
120-277V
50/60 Hz
HOT/LINE
BLACK
NEUTRAL
WHITE
GROUND
GREEN
DATE: 07/14/2016
N2
DRAWN BY: CEH
N2
CHECKED BY:
SCALE: NTS
SHEET NAME
KETRA N2
New Construc tion
KEY
TRANET MESH
IRELESS NETWORK
Retrofit Installation
SHEET
* X2 and load on same circuit should
X2 INSTALLATION GUIDE
N2,
DIMMER
beELV
wired
in parallel,
000023-01-01
1 OF 1
not series.
PAGE 6
OF
1
N2 PL ACE M E NT
Install the N2 at outlet height, near the ground, for ideal KetraNet Mesh
wireless performance.
Ideal N2
Mounting
Location
X2 INSTALLATION GUIDE
000023-01-01
PAGE 7
I N S TA LL ATI O N
N2-REP-3-JBX-BK - KetraNet Mesh Repeater 120-277V
New Construction
1. Install wall box (at least 14 in3 volume per gang).
2. If installing in a multigang box, the side-fins must be removed for fit.
(See Figs 1 and 2)
F
1
2
1
E
D
C
B
3. Run power to wall box utilizing stranded or solid core 12-18 AWG wire.
(See Fig 3)
4. P repare the wire for connection to lead wire: a. Strip 8.5 mm (0.3 in)
of wire for insertion into the wire nut. b. Twist the stranded wire to prevent fraying (tinning optional).
5. Using the provided wire nuts, attach each N2 lead wire to the corresponding conductor. Black-Line, White-Neutral, Green-Ground.
(See Fig 4)
3
1
X2 INSTALLATION GUIDE
4
1
000023-01-01
PAGE 8
I N S TA LL ATI O N
6. Ensure that no conductors are visible after insertion, and that no stray wires are exposed.
7. Carefully tuck wires back into wall box.
8. M ount the N2 to the wall box using the supplied fasteners. Leave the fasteners snug, not fully tight. (See Fig 5)
9. Secure wall plate mount to the N2 using the supplied fasteners.
(See Fig 6)
5
1
6
1
10. Place one serial number sticker on the back of the wall plate. The other can go on building plans or control drawings. (See Fig 7)
11.Attach wall plate to wall plate mount. It will snap into place. (See Fig 8)
7
8
X2.D.ELV
SN: KX12345678
DC: V0216
X2 INSTALLATION GUIDE
X2.D.ELV
SN: KX12345678
DC: V0216
000023-01-01
PAGE 9
I N S TA LL ATI O N
12.E nergize circuit. Note: To install a blank wall plate, first remove the N2’s faceplate: apply pressure to the exposed left edge of the faceplate until it pops loose, then gently remove it.
(See Figs 9 and 10)
9
X2 INSTALLATION GUIDE
10
000023-01-01
PAGE 10
I N S TA LL ATI O N
Retrofit
Important Notes:
• This wiring scheme is for standard in-line 2-Way light switches.
• The wall box should have a volume of 14 in3 or greater.
• The N2 does not have to be on the same circuit as any Ketra fixtures, as all control signals are wireless.
•
Because Ketra fixtures can be turned on and off wirelessly, it is recommended that they not be wired to a light switch if the installation has Ketra controllers. In a retrofit installation where the N2 is replacing a light switch, it is okay to wire the Ketra fixtures directly to the N2. (See Fig 11)
11
N2
* X2 and load on same circuit should be wired in parallel, not series.
1. Turn off power feed to the switch to be replaced.
2. Remove existing switch.
3. Continue with step 3 in the New Construction section, Page 8.
X2 INSTALLATION GUIDE
000023-01-01
PAGE 11
WA R R ANT Y & TECH S U PP O RT
Limited warranty terms can be found at:
www.ketra.com/warranty
For questions and technical support please contact:
+1.512.872.4349
support@ketra.com
+1.512.347.1100 www.ketra.com
3815 South Capital of Texas Highway
Suite 100 • Austin • Texas 78704
© 2016 Ketra. Inc. All rights reserved.
X2 INSTALLATION GUIDE
000023-01-01
PAGE 12