MS. SANDY HSU MEAN WELL ENTERPRISES CO LTD 28 WU-CHUAN 3RD RD WUGU INDUSTRIAL PARK TAIPEI HSIEN 248 TAIWAN Date: Subscriber: PartySite: File No: Project No: PD No: Type: PO Number: 05/19/2010 710861002 156523 E183223 10CA22607 10O20017 R 98-0891 Subject: UL Certification Documents For Applicant This authorization is effective from the date of this Notice and only for products produced at the manufacturing location(s) specified on the current Authorization Page. Records in the Follow-Up Services Procedure covering the product are identified on the Addendum and attached. Products that bear the UL Mark shall be identical to those that were evaluated by UL and found to comply with UL’s requirements. If changes in construction are discovered, appropriate action will be taken for products not in compliance and continued use of the UL Mark may be withdrawn. UL may elect to withdraw use of the UL Mark if the Applicant or Manufacturer fails to comply with UL's requirements, including ongoing compliance of the product under UL's Follow-Up Services. The contents of this Letter are intended solely for the use of UL, the Applicant and specified Manufacturers. The opinions and findings of UL represent its judgment given with due consideration to the limitations of practical operation in accordance with UL’s objectives and purposes. UL shall not incur any obligation or liability for any loss, expense or damages, including incidental, consequential or punitive damages, arising out of or in connection with the use or reliance upon the contents of this letter to anyone other than the Applicant as provided in the agreement between UL and Applicant. Any use or reference to UL’s name or certification mark(s) by anyone other than the Applicant in accordance with the agreement is prohibited without the express written approval of UL. This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee of UL. The following material resulting from the investigation under the above numbers is enclosed. Document Index UL Test Report 05/19/10 Volume X1 X1 Report Reference Status E183223-A123-UL-1 Date New Please file revised Authorizations, Indices, and General Inspection Instructions in place of material of like identity. New Test Reports should be filed immediately following the last Test Report. Amendments or Corrections should be filed immediately before the Test Report to which they relate. Re-issued Test Reports should be filed immediately before all material related to the Test Report that it replaces. NOTE: Manufacturers receive only the following sub-sections of the Applicant’s complete Test Report, where applicable: Cover Page, Specific Inspection Criteria (BA through BE), Specific Technical Criteria (through section CF), Critical Components table, and Enclosures containing image supplements. Manufacturers do not receive Test Report information related to standard clause compliance or testing results. NOTE: Manufacturers that require an Initial Product Inspection (IPI) have received their copy of the Follow-Up Service Procedure, but are instructed they are not allowed to ship products bearing the UL Mark until their UL Representative has successfully conducted the Initial Production Inspection. Please review this material and report any inaccuracies to UL Canada Customer Service, PHONE: 1-866-9373ULC (1-866-937-3852), FAX: 1-416-757-8727, E-MAIL: CustomerService.ca@ca.ul.com, referring to the above Project and/or PD Numbers. This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any authorized licensee of UL. c: TRT File File E183223 Volume Page Date: X1 1 18-May-10 Index Index Product Type Model/Type Reference Report Reference # Open Frame Power Supply Open Frame Power Supply Switching Power Supply PD-45PR E183223-A8-UL-1 PPQ-1003X, where X may be A, B, C, or D. E183223-A10-UL-1 S-40-w where w can be 5, 12, 15, or 24 S-60-x where x can be 5, 9, 12, 15 or 24 D-60y, where y can be A or B T-60z, where z can be A, B, BTE or C PTsb-181CL, and PTsb-205CL E183223-A12-UL-1 Models DRP-240-x (where x can be 24 or 48) E183223-A14-UL-1 DR-120-x (where x can be 12, 24 or 48) E183223-A16-UL-1 UR24-6, UR48-3 E183223-A15-UL-1 DP-260OR, DP -130OR E183223-A18-UL-1 Open Frame Power Supply Switching Power Supply Switching Power Supply Switching Power Supply Switching Power Supply Switching Power Supply E183223-A13-UL-1 Models Rx-y -z, where x can be S, D, ID, T or Q; E183223-A19-UL-1 y can be 85, 100 and z can be 3.3, 5, 12, 15, 24, 48, A, B, C, or D. Switching Power Models Rx-y -z, where x can be S, D, ID, T or Q; E183223-A22-UL-1 Supply y can be 65, 75 and z can be 3.3, 5, 12, 15, 24, 48, A, B, C, or D. DIN RAIL Power DRT-240-24, DRT-240-48. E183223-A20-UL-1 Supply Switching Power RS-25-x, where x can be 3.3, 5, 12, 15, 24, 48. E183223-A23-UL-1 Supply Switching Power Rx-50y, where x can be S, D, T, ID or Q, y can E183223-A26-UL-1 Supply be -3.3, -5, -12, -15, -24, -48, A, B, C or D. Switching Power RS-35-x, where x can be 3.3, 5, 12, 15, 16, 24 E183223-A25-UL-1 Supply or 48. RD-35y where y can be A, B or 13. Switching Power Rx-yz, where x can be S, D, T, ID or Q; y can be E183223-A24-UL-1 Supply 125 or 150; z can be -3.3, -5, -12, -15, -24, -48, -1224, -1248, -2448, -2412, -4812, -4824, A, B, C or D. RID-125-1205, RID-125-2405, RS-150-7.5, RS150-9 NES-150-x, where x=3.3, 5, 7.5, 9, 12, 15, 24, 48 Switching Power PSP-600-x, where x can be 5, 12, 13.5, 15, 24, E183223-A28-UL-1 Supply 27, 32 or 48. Switching Power SP-750-x, where x can be 5, 12, 15, 24, 27, 36 E183223-A27-UL-1 Supply or 48 and SP-750-yAPI-1, where y can be 24 or 48, File E183223 Index Volume Page Date: X1 2 18-May-10 SP-750-yOCE ans SP-750-yOCE where y can be 24 or 48 Open frame LPS-50-X, X = 3.3, 5, 7.5, 12, 13.5, 15, 24, 27, E183223-A5-UL-2 power supply 48 Power Supply DR-480-X, DRP-480-X, DR-480S -X, DRP E183223-A17-UL-3 480S -X (X = 24, 48) Switching Power PD-85SP E183223-A31-UL-1 Supply Redundant Power MP1K0-aaaaaaa, MP1K0-aaaaab, MP1K0E183223-A36-UL-1 Supply aaaaba, MP1K0-aaabaa, MP1K0-aabaaa, MP1K0-abaaaa, MP1K0-baaaaa, MP1K0bbaaa-c, MP1K0-abbaa-c, MP1K0-aabba-c, MP1K0-aaabb-c, MP1K0-babaa, MP1K0-baaba, MP1K0-baaab, MP1K0-aabab, MP1K0-ababa, MP1K0-abaab, MP1K0-bbba-c, MP1K0-abbb-c, MP1K0-babb-c, MP1K0-bbab-c, where a can be A-X or #; b can be 2A-2K or ##; c can be 1, 2, 3, 4, 5, 6 or blank. Redundant Power MP650-aaaaa, MP650-aaab, MP650-aaba, E183223-A32-UL-1 Supply MP650-abaa, MP650-baaa, MP650-abb-c, MP650-bba-c, MP650-bab, where a can be A-X or #; b can be 2A-2K or ##; c can be 1, 2 or blank. DIN RAIL Power DRT-960X-Y (X = P or blank; Y = 24 or 48) E183223-A34-UL-1 Supply Switching Power DR-60-x, where x can be 5, 12, 15, or 24. E183223-A37-UL-1 Supply Switching Power DR-30-x, where x can be 5, 12, 15, or 24. E183223-A33-UL-1 Supply Switching Power IPC-300A, IPC-300B, IPC-250, IPC-200 E183223-A41-UL-1 Supply Switching Power USP-350-x (x = 3.3, 5, 12, 15, 24, 48, 53AD) E183223-A45-UL-1 Supply Other SP-125CL E183223-A47-UL-1 Switching Power NES-15-x (x = 5, 12, 15, 24, 48) E183223-A50-UL-1 Supply (For BuiltIn) Switching Power NES-25-x (x = 5, 12, 15, 24, 48) E183223-A51-UL-1 Supply (For BuiltIn) Switching Power NES-100-x (x = 5, 7.5, 9, 12, 15, 24, 48) E183223-A58-UL-1 Supply (For BuiltIn) Switching Power RPX-65Y, where X may be D or T, and Y may E183223-A62-UL-1 Supply (Building- be C, D, E, F or G. in type) Switching Power QP-320D, QP-320F E183223-A60-UL-1 Supply, Openframe, Built-In Switch Model S-100-F-x (x=5, 7.5, 12, 15, 24, or 48) E183223-A63-UL-1 Power Supplies Switching Power SP-480-15AE, SP-480-x, where x can be 3.3, 5, E183223-A9-UL-2 Supply 12, 15, 24, 48, PSP-450-53PD Switching Power PPS-200-x (x = 5, 12, 15, 24, 27, 48) E183223-A65-UL-1 File E183223 Supply, OpenFrame, Built-In Switching Power Supply Switching Power Supply Switching Power Supply Open Frame Switching Power Supply Switching Power Supply Index Volume Page Date: X1 3 18-May-10 SE-1000-X where X can be 5, 9,12,15, 24 or 48. E183223-A66-UL-1 PT-4503CO E183223-A70-UL-1 ASP-150-X (X = 12, 15, 20, 24, 27 or 48) E183223-A72-UL-1 PS-35-X, where X can be 3.3, 5, 7.5, 12, 13.5, 15, 24, or 48. E183223-A74-UL-1 Switching Power Supply Unit: E183223-A78-UL-1 RSP-1000-x, where x can be 12, 15, 24, 27 or 48 RCP -1000-xy, where x can be 12, 24 or 48, y=C or Blank Backplane rack: RCP -1Uz, where z can be I or T Battery Charger Switching Power supply with Rack: RCP -3K1Uz-xy, x can be 12, 24 or 48, y can be -C or blank, and z can be I or T. Mounting Rack PB-xy-z where x (total output power) can be 300 E183223-A80-UL-1 or 360, y can be P (with PFC choke) or N (no PFC choke) and z (output voltage) can be 12, 24 or 48 or 48ET-1 PID-250X, where X can be A, B, C or D E183223-A81-UL-1 Open Frame Switching Power Supply DC-DC Converter NSD15-xyz (x can be 12 or 48; y can be S or D; z can be 3, 5, 12 or 15) DC-DC converter NSD10-xyz (x can be 12 or 48; y can be S or D; z can be 3, 5, 9, 12 or 15) DIN RAIL Power DRH-120-24 and DRH-120-48 Supply Switching Power RS-15-X where X may be 3.3, 5, 12, 15, 24 or Supply 48 Switching Power USP-500-X where X denotes output voltage Supply which may be 5, 12, 15, 24 or 48. DIN Rail Power DR-100-X where X denotes output voltage, Supply which may be 12, 15 or 24. DIN RAIL Power DRT-480-24, DRT-480-48 and DRT-480-36PE Supply Open Frame PPx-125y, where x can be S or T; when x equal Switching Power to S, that y will be -3.3, -5, -9, -12, -13.5, -15, Supply 24, -27 or -48; when x equal to T that y will be A, B, C or D. Open frame switching power supply Single Output E183223-A83-UL-1 E183223-A82-UL-1 E183223-A84-UL-1 E183223-A85-UL-1 E183223-A86-UL-1 E183223-A87-UL-1 E183223-A21-UL-2 E183223-A7-UL-2 PPT-125AA RPS-60-12AT E183223-A90-UL-1 MDR-x-y ( x = 40 or 60, y = 5, 12, 24, 48) E183223-A91-UL-1 File E183223 Index Volume Page Date: X1 4 18-May-10 Industrial DIN Rail Power Supply DC-DC Power SD-200C-24 E183223-A93-UL-1 Supply Switching Power P-600-13.8, P-600-27, P-600-48, SE-600-5, SE- E183223-A2-UL-3 Supply 600-12, SE-600-15, SE-600-24, SE-600-27, SE600-36, SE-600-48, CE-S600-24-B 2/8 Stage PB-1000-x E183223-A94-UL-1 Switching Mode Battery Charger Where x (output voltage) can be 12, 24, 48. Open Frame Pw-120x-yPzz, where w can be S, A, or B; E183223-A95-UL-1 Switching Power where x can be P or N; where y can be 13, 27, Supply or 54; and where z can be 0-9, A-Z, or blank. Switching Power PID-24RC E183223-A98-UL-1 Supply Switch mode type ID-60B, IT-60D, IT-60F, IQ-60D, IQ-60F E183223-A1-UL-3 power supply Switching Power Model: NED-100XY, X=A, B, C, D for output E183223-A100-UL-1 Supply rating differences; Y=GD (Secondary Output Functional Earthing separated without Jump (J101) or blank (Secondary Output connected with Functional Earthing together) Switching Power CLG-150-XY E183223-A96-UL-2 Supply (X=12, 15, 20, 24, 30, 36, or 48; Y=A, B or C) Building-In PSC-60A, PSC-60B E183223-A101-UL-1 Switching Power Supplies Building-In SE-450-X, where X can be 3.3, 5, 12, 15, 24, 36 E183223-A102-UL-1 Switching Power or 48 Supply Building-In SE-1500-X, where X can be 5, 12, 15, 24, 27 or E183223-A103-UL-1 Switching Power 48 Supplies Switching Power HRPX-150-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A106-UL-1 Supply 15, 24, 36, 48). Building-In RSP-3000-X, where X can be 12, 24, or 48 E183223-A104-UL-1 Switching Power Supplies RSP-2400-X, where X can be 12, 24, or 48 Single Output DR-15-X (X may be 5, 12, 15, or 24) E183223-A105-UL-1 Industrial DIN Rail Power Supply Redundant Power MP450-aaaaa, MP450-aaab, MP450-aaba, E183223-A35-UL-2 Supply NP450-abaa, MP450-baaa, MP450-abb-c, MP450bba-c, MP450-bab, where a can be A-X or #; b can be 2A-2K or ##; c can be 1, 2 or blank. Open Frame MPT-120BC88 E183223-A108-UL-1 Switching Power Supply Switching Power HRPX-600-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A109-UL-1 Supply 15, 24, 36, 48), HRPG-600-48UN File E183223 Switching Power Supply Building-In Switching Power Supplies Switching Power Supplies Switching Power Supply Index Volume Page Date: X1 5 18-May-10 ELN-30-9, ELN-30-9GE E183223-A110-UL-1 PSC-100A, PSC-100B, PSC-100AHO E183223-A111-UL-1 HRPX-300-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A112-UL-1 15, 24, 36, 48) SP-320-3.3, SP-320-5, SP-320-7.5, SP-320-12, E183223-A3-UL-4 SP-320-13.5, SP-320-15, SP-320-24, SP-32027, SP-320-36, SP-320-48, SP-320-7.5EV, SP320-36NP, SPV-300-12, SPV-300-24, SPV-30048, SPV-150-12, SPV-150-24, SPV-150-48 Switching Power RSP-1500-X (X can be 5, 12, 15, 24, 27, 27VS, E183223-A39-UL-2 Supply 48); SPV-1500-X (X can be 12, 24, 48). Note: X denotes output DC voltage. Switching Power SP-240-X, X = 5, 7.5, 12, 15, 24, 30, 48 E183223-A114-UL-1 Supplies Open Frame LPS-75-3.3, LPS-75-5, LPS-75-12, LPS-75-15, E183223-A4-UL-3 Power Supply LPS-75-24, LPS-75-48. LPS-75-24GR Switching Power HRP -75-X, X = 3.3, 5, 7.5, 12, 15, 24, 36, 48 E183223-A115-UL-1 Supplies Switching Power HRP -100-X (X = 3.3, 5, 7.5, 12, 15, 24, 36, 48) E183223-A119-UL-1 Supplies Switching Power HLG-240x-yz (x can be H or blank, y can 12, 15, E183223-A117-UL-1 Supply 20, 24, 30, 36, 42, 48 or 54, z can be A, B, C or blank) Switching Power ELP-75-X (X = 3.3, 5, 12, 15, 24, 36, 48) E183223-A121-UL-1 Supplies Switching Power MP450-2KSX#-AG E183223-A118-UL-1 Supply Switching Power HRPX-200-Y (X = G or blank for marketing; Y = E183223-A120-UL-1 Supply 3.3, 5, 7.5, 12, 15, 24, 36, 48 for output voltage) Switching Power NEx-35y (x = S, D,T; y = -5, -12, -15, -24, -48, E183223-A52-UL-2 Supply (For Built- A, B, C, D), SCP-35-12, SCP-35-24 In) Switching Power NEx-75y (x = S, D, T; y = -5, -12, -15, -24, -48, E183223-A57-UL-2 Supply (For Built- A, B, C or D), SCP-75-12, SCP-75-24 In) Switching Power NEx-50y (x = S, D, T; y = -5, -12, -15, -24, -48, E183223-A56-UL-2 Supply (For Built- A, B, C or D), SCP-50-12, SCP-50-24 In) Switching Power HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A123-UL-1 Supply 15, 24, 36, 48) File E183223 Index Volume Page Date: X1 6 18-May-10 Issue Date: 2010-05-19 Page 1 of 2 Report Reference # E183223-A123-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ2, QQGQ8 Test Procedure: Product: Model/Type Reference: Component Recognition Switching Power Supply HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48) Rating(s): Input: 100-240Vac, 50/60Hz, 6.0A Output: HRPX-450-3.3: +3.3Vdc/90A HRPX-450-5: +5Vdc/90A HRPX-450-7.5: +7.5Vdc/60A HRPX-450-12: +12Vdc/37.5A HRPX-450-15: +15Vdc/30A HRPX-450-24: +24Vdc/18.8A HRPX-450-36: +36Vdc/12.5A HRPX-450-48: +48Vdc/9.5A UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements) Standards: Applicant Name and Address: MEAN WELL ENTERPRISES CO LTD 28 WU-CHUAN 3RD RD WUGU INDUSTRIAL PARK TAIPEI HSIEN 248 TAIWAN This Report includes the following parts, in addition to this cover page: 1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. National Differences 7. Enclosures Copyright © 2010 Issue Date: 2010-05-19 Page 2 of 2 Report Reference # E183223-A123-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow -Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow -Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow -Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories Inc(ULI) or any authorized license of ULI. Test Report By: Reviewed By: Joyce Liang Project Engineer Underwriters Laboratories of Canada Inc. Sam Fu Project Engineer Underwriters Laboratories Taiwan Co., Ltd. Copyright © 2010 Issue Date: 2010-05-19 Page 1 of 70 Report Reference # E183223-A123-UL-1 SPECIFIC INSPECTION CRITERIA BA1.0 Special Instructions to UL Representative BA1.1 Inspect the transformer(s) listed in BD1.1 per AA1.1- (C). When the tests are conducted at other location, inspect test record and specification sheet provided by the component manufacturer. Verify the specification sheet indicates 100% routine test specified in BD1.1 be conducted at the component manufacturer. BB1.0 Supporting Documentation BB1.1 The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. BC1.0 Markings and instructions BC1.1 The following markings and instructions are provided as indicated. BC1.2 All clause references are from UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements). Standard Clause Clause Title Marking or Instruction Details 1.7.1 Power rating Ratings Ratings (voltage, frequency/dc, current) Power rating Company identification Listee's or Recognized company's name, Trade Name, Trademark or File Number Power rating Model Model Number 1.7.6 Fuses - NonUnambiguous reference to service documentation for instructions for operator replacement of fuses replaceable only by service personnel access/solderedin fuses TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Fuses - Rating Page 2 of 70 Report Reference # E183223-A123-UL-1 Rated current and voltage and type located on or adjacent to fuse or fuseholder. BD1.0 Production-Line Testing Requirements BD1.1 Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information. Test Potential Model Component Test V dc Time, s Test probe location HRPXTransformer 450-Y (T1) (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48) N/A Primary to Secondary 3000 424 2 1 HRPXTransformer 450-Y (T900 when (X=G or provided) blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48) N/A Primary to Secondary 3000 424 2 1 BD1.2 Earthing Continuity Test Exemptions - This test is not required for the following models: -- BD1.3 Electric Strength Test Exemptions - This test is not required for the following models: -- BD1.4 Electric Strength Test Component Exemptions - The following solid-state components may be disconnected from the remainder of the circuitry during the performance of this test: -- BE1.0 V rms Removable Parts Sample and Test Specifics for Follow-Up Tests at UL BE1.1 Model -- TRF No. IECEN60950_1C Component -- Material -- Test -- Underwriters Laboratories Inc. Sample(s) -- Test Specifics -- Issue Date: 2010-05-19 Page 3 of 70 Report Reference # E183223-A123-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1:2005 (2nd Edition) Information technology equipment - Safety Part 1: General requirements Report Reference No ..................... : E183223-A123-UL-1 Compiled by ................................. : Joyce Liang Reviewed by ................................. : Sam Fu Date of issue ................................ : 2010-05-19 Standards ..................................... : UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure .............................. : Component Recognition Non-standard test method ............. : N/A Test item description .................... : Switching Power Supply Trademark .................................... : None Model and/or type reference .......... : HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48) Rating(s) ...................................... : Input: 100-240Vac, 50/60Hz, 6.0A Output: HRPX-450-3.3: +3.3Vdc/90A HRPX-450-5: +5Vdc/90A HRPX-450-7.5: +7.5Vdc/60A HRPX-450-12: +12Vdc/37.5A HRPX-450-15: +15Vdc/30A HRPX-450-24: +24Vdc/18.8A HRPX-450-36: +36Vdc/12.5A HRPX-450-48: +48Vdc/9.5A TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 4 of 70 Report Reference # E183223-A123-UL-1 Particulars: test item vs. test requirements Equipment mobility ................................................: for building-in Connection to the mains ........................................: To be evaluated in end product Operating condition ...............................................: continuous Over voltage category ...........................................: OVC II Mains supply tolerance (%) ....................................: +10%, -10% (Declared by Manufacturer) Tested for IT power systems ..................................: No IT testing, phase-phase voltage (V) ........................: N/A Class of equipment ...............................................: Class I (earthed) Mass of equipment (kg) .........................................: 1.1Kg Pollution degree ....................................................: PD 2 IP protection class .................................................: IP X0 Possible test case verdicts: - test case does not apply to the test object .............: N / A - test object does meet the requirement ..................: Pass - test object does not meet the requirement ............: Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 5 of 70 Report Reference # E183223-A123-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A CB1.0 Product Description CB1.1 The devices are AC/DC switching power supplies. Each consists of electronic components mounted on PWBs enclosed in a metal enclosure. Each has two terminal blocks and a DC fan. CC1.0 Model Differences CC1.1 All models have identical schematic and PWB layout. Models with different X in model number are identical except for model designation. Mocdel with different Y in model number are identical except for transformer T1 secondary and some secondary components. See Enclosure ID 5-01 for detailed model differences. CD1.0 Additional Information CD1.1 N/A CE1.0 Technical Considerations CE1.2 The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer’s specification of: 50°C CE1.3 The means of connection to the mains supply is: To be evaluated in end product CE1.4 The product is intended for use on the following power systems: TN CE1.5 The equipment disconnect device is considered to be: To be evaluated in end product. CE1.13 The following are available from the Applicant upon request: Specific data sheets for LED indicators that are class I and operate at wavelength in the 400-710 nm range., Installation (Safety) Instructions / Manual CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following: CF1.2 The following Production-Line tests are conducted for this product: Electric Strength, Earthing Continuity CF1.3 The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-SELV: 303 Vrms, 480 Vpk, Primary-Earthed Dead Metal: 303 Vrms, 480 Vpk CF1.5 The following secondary output circuits are SELV: All outputs TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 6 of 70 Report Reference # E183223-A123-UL-1 CF1.6 The following secondary output circuits are at hazardous energy levels: All outputs CF1.10 The following output terminals were referenced to earth during performance testing: Transformer T1 (pin FL2 or output -V); Transformer T900 (pin 7, 8 or AUXG). CF1.11 The power supply terminals and/or connectors are: Not investigated for field wiring CF1.12 The maximum investigated branch circuit rating is: 20 A CF1.13 The investigated Pollution Degree is: 2 CF1.15 Proper bonding to the end-product main protective earthing termination is: Required CF1.16 An investigation of the protective bonding terminals has: Been conducted CF1.17 The following input terminals/connectors must be connected to the end-product supply neutral: Terminal AC/N from input terminal block TB1. CF1.18 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105°C): T1 (Class B) & T900 (Class B) CF1.19 The following end-product enclosures are required: Mechanical, Electrical, Fire CF1.20 The following components require special consideration during end-product Thermal (Heating) tests due to the indicated maximum temperature measurements during component-level testing: ZNR1 body CF2.0 Terminal FG from the input terminal block TB1 shall be properly bonded to the protective grounding terminal of the end product and the ground traces of the PWB shall be investigated according to clause 2.6.3.4. TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 7 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test 1 GENERAL Pass 1.5 Components Pass 1.5.1 General Pass 1.5.2 Result - Remark Verdict Comply with IEC 60950 or relevant component standard (see appended table 1.5.1) Pass Evaluation and testing of components Components certified to IEC harmonized standard and checked for correct application. Components, for which no relevant IECStandard Pass exist, have been tested under the conditions occurring in the equipment, using applicable parts of IEC 60950-1. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC 60950-1 and the relevant component Standard. 1.5.3 Thermal controls Thermal Controls comply with Annex K, see Annex K Thermal Controls. Pass 1.5.4 Transformers Transformers used are suitable for their intended applications and comply with relevant parts of this standard and particularly Annex C. Pass 1.5.5 Interconnecting cables No interconnecting cables provided 1.5.6 Capacitors bridging insulation Line-to-Neutral capacitors are subclass X1 or X2. Primary-t o-earth capacitors are subclass Y1 or Y2. Bridging capacitor C31 is subclass Y1 Pass 1.5.7 Resistors bridging insulation Resistors only bridge functional insulation. Pass 1.5.7.1 Resistors bridging functional, basic or supplementary insulation 1.5.7.2 Resistors bridging double or reinforced insulation TRF No. IECEN60950_1C Underwriters Laboratories Inc. N/A Pass N/A Issue Date: 2010-05-19 Page 8 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict between a.c. mains and other circuits 1.5.7.3 Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable 1.5.7.4 Accessible parts To be evaluated in end product. N/A 1.5.8 Components in equipment for IT power systems Not for use on IT systems. N/A 1.5.9 Surge suppressors Pass 1.5.9.1 General Pass 1.5.9.2 Protection of VDRs 1.5.9.3 Bridging of functional insulation by a VDR 1.5.9.4 Bridging of basic insulation by a VDR 1.5.9.5 Bridging of supplementary, double or reinforced insulation by a VDR N/A 1.6 Power interface Pass 1.6.1 AC power distribution systems TN power system Pass 1.6.2 Input current The steady state input current of the equipment did not exceed the RATED CURRENT by more than 10% under NORMAL LOAD. (see appended table 1.6.2) Pass 1.6.3 Voltage limit of hand-held equipment 1.6.4 Neutral conductor TRF No. IECEN60950_1C N/A Fuse FS1 rated F8A/250V is used before the VDR. Pass Pass Only functional insulation is bridged by VDR. N/A N/A Pass Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 9 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 1.7 Marking and instructions 1.7.1 Power rating Verdict Pass Rating marking readily visible to operator Rated voltage(s) or voltage range(s) (V).............. : 100-240Vac Symbol for nature of supply, for d.c. only............. : Pass Pass N/A Rated frequency or rated frequency range (Hz)... : 50/60 Hz. Pass Rated current (mA or A)..................................... : 6.0A Pass Manufacturer's name or trademark or identification Mean Well or E183223 mark ................................................................. : Pass Model identification or type reference.................. : HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48). Pass Symbol for Class II equipment only ..................... : N/A Other markings and symbols .............................. : Additional symbols do not give rise to misunderstanding. Pass 1.7.2 Safety instructions and marking Pass 1.7.2.1 General 1.7.2.2 Disconnect devices To be evaluated in the end product. N/A 1.7.2.3 Overcurrent protective device To be evaluated in the end product N/A 1.7.2.4 IT Power distribution systems N/A 1.7.2.5 Operator access with a tool N/A 1.7.2.6 Ozone N/A 1.7.3 Short duty cycles N/A 1.7.4 Supply voltage adjustment ................................. : Auto-ranging. N/A Method and means of adjustment; reference to installation instructions ....................................... : N/A 1.7.5 Power outlets on the equipment ......................... : No standard power outlets are provided. N/A 1.7.6 Fuse identification (marking, special fusing FS1, 8A/250V characteristics, cross-reference)......................... : 1.7.7 Wiring terminals 1.7.7.1 Protective earthing and bonding terminals........... : Protective earthing to be evaluated in end product. N/A 1.7.7.2 Terminal for a.c. mains supply conductors N/A TRF No. IECEN60950_1C Operating/safety instructions made available to the user. Pass To be evaluated in end product. Terminals intended for connection of the primary Underwriters Laboratories Inc. Pass N/A Issue Date: 2010-05-19 Page 10 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict power neutral conductor indicated by the capital letter N. Marking not placed on any part which might be removed when conductors are being connected. The suitability of the terminals for connection to the AC Mains supply shall be evaluated in the end product. 1.7.7.3 Terminals for d.c. mains supply conductors 1.7.8 Controls and indicators Pass 1.7.8.1 Identification, location and marking ..................... : The function of controls affecting safety is obvious regardless of language. Pass 1.7.8.2 Colours ............................................................. : A green LED is illuminated when the unit is operating. Pass 1.7.8.3 Symbols according to IEC 60417 ........................ : N/A 1.7.8.4 Markings using figures ....................................... : N/A 1.7.9 Isolation of multiple power sources ..................... : There is only one connection to hazardous voltages. N/A 1.7.10 Thermostats and other regulating devices ........... : No adjustable thermostats or similar regulating devices. N/A 1.7.11 Durability All markings provided on UL Recognized Component labels suitable for surface they are applied upon and meet the durability test. Pass 1.7.12 Removable parts No marking is located on (a) removable part(s). Pass 1.7.13 Replaceable batteries ........................................ : No batteries 1.7.14 N/A N/A Language(s)...................................................... : - Equipment for restricted access locations............ : N/A TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 11 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 2 PROTECTION FROM HAZARDS Pass 2.1 Protection from electric shock and energy hazards Pass 2.1.1 Protection in operator access areas To be evaluated in end product. Pass 2.1.1.1 Access to energized parts For building-in. Accessibility is to be evaluated in end product. Pass Test by inspection ............................................. : N/A Test with test finger (Figure 2A).......................... : N/A Test with test pin (Figure 2B).............................. : N/A Test with test probe (Figure 2C) ......................... : N/A 2.1.1.2 Battery compartments N/A 2.1.1.3 Access to ELV wiring N/A Working voltage (Vpeak or Vrms); minimum distance through insulation (mm)........................ : - 2.1.1.4 Access to hazardous voltage circuit wiring N/A 2.1.1.5 Energy hazards ................................................. : The output of the power supplies presents an energy hazard. No operator access permitted. To be evaluated in end product. N/A 2.1.1.6 Manual controls N/A 2.1.1.7 Discharge of capacitors in equipment Measured voltage (V); time-constant (s).............. : line-to-line: V0 (original V)=364pk; 37%V0=135 V; Voltage at 1 second = 0 V 2.1.1.8 Pass - Energy hazards - d.c. mains supply N/A a) Capacitor connected to the d.c. mains supply .. : N/A b) Internal battery connected to the mains supply : N/A 2.1.1.9 Audio amplifiers ................................................. : N/A 2.1.2 Protection in service access areas N/A 2.1.3 Protection in restricted access locations N/A TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 12 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 2.2 SELV circuits Pass 2.2.1 General requirements Pass 2.2.2 Voltages under normal conditions (V).................. : Not exceed 42,4 V peak, or 60 V d.c. Pass 2.2.3 Voltages under fault conditions (V) ..................... : Not exceed 42,4 V peak, or 60 V d.c. for longer than 200 ms and moreover, not exceed 71 V peak or 120 V d.c. Pass 2.2.4 Connection of SELV circuits to other circuits ....... : SELV connected to limited current circuit. Pass 2.3 TNV circuits 2.3.1 Limits N/A No TNV presents N/A Type of TNV circuits .......................................... : - 2.3.2 Separation from other circuits and from accessible parts N/A 2.3.2.1 General requirements N/A 2.3.2.2 Protection by basic insulation N/A 2.3.2.3 Protection by earthing N/A 2.3.2.4 Protection by other constructions ........................ : N/A 2.3.3 Separation from hazardous voltages N/A Insulation employed........................................... : 2.3.4 Connection of TNV circuits to other circuits Insulation employed........................................... : 2.3.5 Test for operating voltages generated externally TRF No. IECEN60950_1C Underwriters Laboratories Inc. N/A N/A Issue Date: 2010-05-19 Page 13 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 2.4 Limited current circuits 2.4.1 General requirements For secondary of Bridging Capacitor C31 Pass 2.4.2 Limit values 0.7 mA peak Pass Pass Frequency (Hz) ................................................. : 60 - Measured current (mA) ...................................... : 0.59 - Measured voltage (V) ........................................ : 1.18 - Measured circuit capacitance (nF or uF) ............. : 2200pF - 2.4.3 Connection of limited current circuits to other circuits Pass 2.5 Limited power sources N/A a) Inherently limited output N/A b) Impedance limited output N/A c) Regulating network limited output under normal operating and single fault condition N/A d) Overcurrent protective device limited output N/A Max. output voltage (V), max. output current (A), max. apparent power (VA) ................................. : - Current rating of overcurrent protective device (A): - TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 14 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 2.6 Provisions for earthing and bonding 2.6.1 Protective earthing To be evaluated in end Product. 2.6.2 Functional earthing Functional earthing separated from Hazardous voltage by reinforced insulation. Pass 2.6.3 Protective earthing and protective bonding conductors Tobe evaluated in end product N/A 2.6.3.1 General N/A 2.6.3.2 Size of protective earthing conductors N/A Pass Rated current (A), cross-sectional area (mm²), AWG ................................................................ : 2.6.3.3 Verdict N/A - Size of protective bonding conductors N/A Rated current (A), cross-sectional area mm²), AWG ........................................................................ : - 2.6.3.4 Resistance of earthing conductors and their Test current 40A: terminations; resistance (ohm), voltage drop (V), Ground pin - chassis: Voltage test current (A), duration (min)............................ : drop 0.43V N/A 2.6.3.5 Colour of insulation ............................................ : Not used. N/A 2.6.4 Terminals N/A 2.6.4.1 General N/A 2.6.4.2 Protective earthing and bonding terminals N/A To be evaluated in end product. Rated current (A), type, nominal thread diameter (mm)................................................................. : - 2.6.4.3 Separation of the protective earthing conductor from protective bonding conductors 2.6.5 Integrity of protective earthing 2.6.5.1 Interconnection of equipment N/A 2.6.5.2 Components in protective earthing conductors and protective bonding conductors N/A 2.6.5.3 Disconnection of protective earth N/A 2.6.5.4 Parts that can be removed by an operator N/A 2.6.5.5 Parts removed during servicing N/A 2.6.5.6 Corrosion resistance N/A 2.6.5.7 Screws for protective bonding 2.6.5.8 Reliance on telecommunication network or cable TRF No. IECEN60950_1C N/A To be evaluated at endproduct. Metal thickness at least twice the pitch of the screw. Underwriters Laboratories Inc. N/A N/A N/A Issue Date: 2010-05-19 Page 15 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict distribution system 2.7 Overcurrent and earth fault protection in primary circuits Pass 2.7.1 Basic requirements Pass Protective devices are integrated in the equipment. Instructions when protection relies on building installation N/A 2.7.2 Faults not covered in 5.3.7 Protection from faults not covered in 5.3 are provided by end installation. Pass 2.7.3 Short-circuit backup protection The building installation is considered as providing shortcircuit backup protection. Pass 2.7.4 Number and location of protective devices .......... : One protective device (Fuse FS1) in the "LIVE" phase 2.7.5 Protection by several devices 2.7.6 Warning to service personnel ............................. : N/A 2.8 Safety interlocks N/A 2.8.1 General principles N/A 2.8.2 Protection requirements N/A 2.8.3 Inadvertent reactivation N/A 2.8.4 Fail-safe operation N/A 2.8.5 Moving parts N/A 2.8.6 Overriding N/A 2.8.7 Switches and relays N/A 2.8.7.1 Contact gaps (mm) ............................................ : N/A 2.8.7.2 Overload test N/A 2.8.7.3 Endurance test N/A 2.8.7.4 Electric strength test N/A 2.8.8 Mechanical actuators N/A TRF No. IECEN60950_1C Only one protective device is provided. Underwriters Laboratories Inc. Pass N/A Issue Date: 2010-05-19 Page 16 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 2.9 Electrical insulation 2.9.1 Properties of insulating materials Natural rubber, materials containing asbestos and hygroscopic materials are not used as insulation.Adequate clearances and creepage distances. Pass 2.9.2 Humidity conditioning Electric strength test was conducted after the humidity treatment. Pass Pass Relative humidity (%), temperature (°C) .............. : 95%, 40°C, 48 hours. 2.9.3 Grade of insulation 2.9.4 Separation from hazardous voltages Adequate level of safety insulation is provided and maintained to comply with the requirements of this standard. Method(s) used ................................................. : Primary circuit separated from Secondary circuit by double insulation or reinforced insulation. TRF No. IECEN60950_1C Verdict Underwriters Laboratories Inc. Pass Pass - Issue Date: 2010-05-19 Page 17 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 2.10 Clearances, creepage distances and distances through insulation Pass 2.10.1 General Pass 2.10.1.1 Frequency......................................................... : 50/60Hz Pass 2.10.1.2 Pollution degrees ............................................... : Pollution Degree 2 Pass 2.10.1.3 Reduced values for functional insulation N/A 2.10.1.4 Intervening unconnected conductive parts N/A 2.10.1.5 Insulation with varying dimensions N/A 2.10.1.6 Special separation requirements N/A 2.10.1.7 Insulation in circuits generating starting pulses N/A 2.10.2 Determination of working voltage 2.10.2.1 General Pass 2.10.2.2 RMS working voltage Pass 2.10.2.3 Peak working voltage Pass 2.10.3 Clearances 2.10.3.1 General Pass 2.10.3.2 Mains transient voltages Pass a) AC mains supply ........................................... : 2500V Pass Pollution degree 2 applicable. See appended table 2.10.3 and 2.10.4 See appended table 2.10.3 and 2.10.4 Verdict Pass Pass b) Earthed d.c. mains supplies............................ : N/A c) Unearthed d.c.. mains supplies ....................... : N/A d) Battery operation ........................................... : N/A 2.10.3.3 Clearances in primary circuits (see appended table 2.10.3 and 2.10.4) Pass 2.10.3.4 Clearances in secondary circuits Compliance criteria for 5.3.4. Pass 2.10.3.5 Clearances in circuits having starting pulses N/A 2.10.3.6 Transients from a.c. mains supply....................... : N/A 2.10.3.7 Transients from d.c. mains supply....................... : N/A 2.10.3.8 Transients from telecommunication networks and cable distribution systems .................................. : N/A 2.10.3.9 Measurement of transient voltage levels N/A a) Transients from a mains supply N/A For an a.c. mains supply .................................... : N/A For a d.c. mains supply ...................................... : N/A b) Transients from a telecommunication network N/A 2.10.4 Creepage distances TRF No. IECEN60950_1C (see appended table 2.10.3 Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 18 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict and 2.10.4) 2.10.4.1 General Pass 2.10.4.2 Material group and comparative tracking index Pass CTI tests ........................................................... : Material Group IIIa or IIIb assumed unless otherwise indicated. 100 <= CTI < 175 - 2.10.4.3 Minimum creepage distances Pass 2.10.5 Solid insulation Pass 2.10.5.1 General Pass 2.10.5.2 Distances through insulation 2.10.5.3 Insulating compound as solid insulation 2.10.5.4 Semiconductor devices 2.10.5.5 Cemented joints 2.10.5.6 Thin sheet material - General Pass 2.10.5.7 Separable thin sheet material Pass UL recognized R/C (FPQU2) optocouplers used. Insulation sheet provides basic insulation only. N/A UL recognized R/C (FPQU2) optocouplers used. Pass N/A Number of layers (pcs)....................................... : 2 layers insulation tape wrap transformer outside. 2 layers insulation tape between primary and secondary of transformers T1 and T900. 2.10.5.8 Non-separable thin sheet material 2.10.5.9 Thin sheet material - standard test procedure UL recognized R/C triple insulated winding wire used T2. Electric strength test .......................................... : 2.10.5.10 Pass Thin sheet material - alternative test procedure Electric strength test .......................................... : (see appended table 5.2) - N/A N/A Pass - 2.10.5.11 Insulation in wound components 2.10.5.12 Wire in wound components N/A Working voltage ................................................ : N/A a) Basic insulation not under stress .................... : N/A b) Basic, supplementary, reinforced insulation..... : N/A c) Compliance with Annex U .............................. : N/A Two wires in contact inside wound component; N/A TRF No. IECEN60950_1C Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 19 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict angle between 45° and 90° ................................ : 2.10.5.13 Wire with solvent-based enamel in wound components N/A Electric strength test .......................................... : 2.10.5.14 - Routine test N/A Additional insulation in wound components N/A Working voltage ................................................ : N/A - Basic insulation not under stress ...................... : N/A - Supplementary, reinforced insulation ................ : N/A 2.10.6 Construction of printed boards Pass 2.10.6.1 Uncoated printed boards 2.10.6.2 Coated printed boards N/A 2.10.6.3 Insulation between conductors on the same inner surface of a printed board N/A 2.10.6.4 Insulation between conductors on different layers of a printed board N/A Distance through insulation N/A Number of insulation layers (pcs)........................ : N/A (see appended table 2.10.3 and 2.10.4) 2.10.7 Component external terminations 2.10.8 Tests on coated printed boards and coated components N/A 2.10.8.1 Sample preparation and preliminary inspection N/A 2.10.8.2 Thermal conditioning N/A 2.10.8.3 Electric strength test N/A 2.10.8.4 Abrasion resistance test N/A 2.10.9 Thermal cycling N/A 2.10.10 Test for Pollution Degree 1 environment and insulating compound N/A 2.10.11 Tests for semiconductor devices and cemented joints N/A 2.10.12 Enclosed and sealed parts N/A TRF No. IECEN60950_1C (see appended table 2.10.3 and 2.10.4) Pass Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 20 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test 3 WIRING, CONNECTIONS AND SUPPLY Pass 3.1 General Pass 3.1.1 Current rating and overcurrent protection Pass 3.1.2 Protection against mechanical damage N/A 3.1.3 Securing of internal wiring N/A 3.1.4 Insulation of conductors N/A 3.1.5 Beads and ceramic insulators N/A 3.1.6 Screws for electrical contact pressure All electrical screw connections are by metal screw with more than 2 threads into a metal plate. 3.1.7 Insulating materials in electrical connections No contact pressure through insulating material. N/A 3.1.8 Self-tapping and spaced thread screws No thread-cutting or space thread screws used. N/A 3.1.9 Termination of conductors 3.1.10 Result - Remark Pass Pass 10 N pull test Checked by Inspection. Sleeving on wiring Heat shrinkable sleeving used. TRF No. IECEN60950_1C Verdict Underwriters Laboratories Inc. N/A Pass Issue Date: 2010-05-19 Page 21 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 3.2 Connection to mains supply 3.2.1 Means of connection To be evaluated in end product. N/A 3.2.1.1 Connection to an a.c. mains supply To be evaluated in end product. N/A 3.2.1.2 Connection to a d.c. mains supply N/A 3.2.2 Multiple supply connections N/A 3.2.3 Permanently connected equipment N/A To be evaluated in end product. Number of conductors, diameter of cable and conduits (mm) ................................................... : N/A - 3.2.4 Appliance inlets No appliance inlet. N/A 3.2.5 Power supply cords A power supply cord is not provided. N/A 3.2.5.1 AC power supply cords N/A Type................................................................. : - Rated current (A), cross-sectional area (mm²), AWG ................................................................ : - 3.2.5.2 DC power supply cords N/A 3.2.6 Cord anchorages and strain relief N/A Mass of equipment (kg), pull (N)......................... : - Longitudinal displacement (mm) ......................... : - 3.2.7 Protection against mechanical damage N/A 3.2.8 Cord guards N/A 3.2.9 Diameter of minor dimension D (mm); test mass (g) ........................................................................ : - Radius of curvature of cord (mm)........................ : - Supply wiring space TRF No. IECEN60950_1C To be evaluated in end product. Underwriters Laboratories Inc. N/A Issue Date: 2010-05-19 Page 22 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 3.3 Wiring terminals for connection of external conductors 3.3.1 Wiring terminals 3.3.2 Connection of non-detachable power supply cords 3.3.3 Screw terminals 3.3.4 Conductor sizes to be connected For building-in. To be evaluated in end product. Pass N/A N/A Pass To be evaluated in end product. Rated current (A), cord/cable type, cross-sectional area (mm²) ........................................................ : 3.3.5 Verdict N/A - Wiring terminal sizes Pass Rated current (A), type and nominal thread R/C (XCFR2) terminal bloack diameter (mm)................................................... : (TB1) rated 300 V ac, 20 A each pin. - 3.3.6 Wiring terminals design Terminals are mounted such that they do not become loose, place stress on internal wiring, or reduce creepage and clearances below those prescribed in 2.9. Pass 3.3.7 Grouping of wiring terminals All mains supply and earthing terminals in close proximity. Pass 3.3.8 Stranded wire TRF No. IECEN60950_1C N/A Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 23 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 3.4 Disconnection from the mains supply 3.4.1 General requirement To be evaluated in end product. N/A 3.4.2 Disconnect devices To be evaluated in end product N/A 3.4.3 Permanently connected equipment To be evaluated in end product. N/A 3.4.4 Parts which remain energized To be evaluated in end product. N/A 3.4.5 Switches in flexible cords N/A 3.4.6 Number of poles - single-phase and d.c. equipment N/A 3.4.7 Number of poles - three-phase equipment N/A 3.4.8 Switches as disconnect devices N/A 3.4.9 Plugs as disconnect devices N/A 3.4.10 Interconnected equipment N/A 3.4.11 Multiple power sources N/A 3.5 Interconnection of equipment Pass 3.5.1 General requirements Pass 3.5.2 Types of interconnection circuits......................... : Interconnection circuits are SELV CIRCUITS. Pass 3.5.3 ELV circuits as interconnection circuits N/A 3.5.4 Data ports for additional equipment N/A 4 PHYSICAL REQUIREMENTS 4.1 Stability N/A Pass N/A Angle of 10° For building-in Test force (N).................................................... : TRF No. IECEN60950_1C Verdict Underwriters Laboratories Inc. N/A N/A Issue Date: 2010-05-19 Page 24 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test 4.2 Mechanical strength Pass 4.2.1 General Pass 4.2.2 Steady force test, 10 N Pass 4.2.3 Steady force test, 30 N Tested on chassis. No hazard as a result of the 30 N test. 4.2.4 Steady force test, 250 N For building-in. To be evaluated in end product. 4.2.5 Impact test N/A Fall test N/A Swing test N/A 4.2.6 Drop test; height (mm) ....................................... : N/A 4.2.7 Stress relief test N/A 4.2.8 Cathode ray tubes N/A Picture tube separately certified.......................... : N/A 4.2.9 High pressure lamps N/A 4.2.10 Wall or ceiling mounted equipment; force (N) ...... : N/A TRF No. IECEN60950_1C Result - Remark Underwriters Laboratories Inc. Verdict Pass N/A Issue Date: 2010-05-19 Page 25 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 4.3 Design and construction 4.3.1 Edges and corners 4.3.2 Handles and manual controls; force (N) .............. : N/A 4.3.3 Adjustable controls N/A 4.3.4 Securing of parts 4.3.5 Connection by plugs and sockets N/A 4.3.6 Direct plug-in equipment N/A Torque .............................................................. : N/A Compliance with the relevant mains plug standard: N/A Pass All edges and corners are judged to be sufficiently well rounded so as not to constitute a hazard. Judged by inspection. No loosening of parts impairing creep age distances or clearances over supplementary or reinforced insulation is likely to occur. Pass Pass 4.3.7 Heating elements in earthed equipment No heating elements. N/A 4.3.8 Batteries No batteries N/A - Overcharging of a rechargeable battery N/A - Unintentional charging of a non-rechargeable battery N/A - Reverse charging of a rechargeable battery N/A - Excessive discharging of any battery N/A 4.3.9 Oil and grease The insulation of the internal wiring is not exposed to oil, grease, etc. N/A 4.3.10 Dust, powders, liquids and gases N/A 4.3.11 Containers for liquids or gases N/A 4.3.12 Flammable liquids ............................................. : N/A Quantity of liquid (l)............................................ : N/A Flash point (°C) ................................................. : N/A 4.3.13 Radiation Pass 4.3.13.1 General N/A 4.3.13.2 Ionizing radiation N/A Measured radiation (pA/kg) ................................ : - Measured high-voltage (kV) ............................... : - Measured focus voltage (kV).............................. : - TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 26 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark CRT markings ................................................... : 4.3.13.3 Verdict - Effect of ultraviolet (UV) radiation on materials N/A Part, property, retention after test, flammability classification ..................................................... : N/A 4.3.13.4 Human exposure to ultraviolet (UV) radiation....... : N/A 4.3.13.5 Laser (including LEDs) Contains only one visible indicator LED (Class 1) operating in the range of 400 700 nm wavelength. No IEC60825-1 evaluation was deemed necessary. Laser class........................................................ : (For indicator LEDs, see above statement.) Pass - 4.3.13.6 Other types ....................................................... : N/A 4.4 Protection against hazardous moving parts N/A 4.4.1 General 4.4.2 Protection in operator access areas .................... : N/A 4.4.3 Protection in restricted access locations .............. : N/A 4.4.4 Protection in service access areas N/A 4.5 Thermal requirements Pass 4.5.1 General Pass 4.5.2 Temperature tests To be evaluated in end product. (see appended table 4.5) Normal load condition per Annex L ..................... : See Annex L. N/A Pass - 4.5.3 Temperature limits for materials Pass 4.5.4 Touch temperature limits Pass 4.5.5 Resistance to abnormal heat .............................. : TRF No. IECEN60950_1C Underwriters Laboratories Inc. N/A Issue Date: 2010-05-19 Page 27 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 4.6 Openings in enclosures 4.6.1 Top and side openings N/A For building-in, fire enclosure to be provided in end product. Dimensions (mm) .............................................. : 4.6.2 Verdict N/A - Bottoms of fire enclosures N/A Construction of the bottom, dimensions (mm) ...... : - 4.6.3 Doors or covers in fire enclosures N/A 4.6.4 Openings in transportable equipment N/A 4.6.4.1 Constructional design measures N/A Dimensions (mm) .............................................. : - 4.6.4.2 Evaluation measures for larger openings N/A 4.6.4.3 Use of metallized parts N/A 4.6.5 Adhesives for constructional purposes N/A Conditioning temperature (°C), time (weeks) ....... : - 4.7 Resistance to fire Pass 4.7.1 Reducing the risk of ignition and spread of flame Pass Method 1, selection and application of components wiring and materials Pass Method 2, application of all of simulated fault condition tests N/A 4.7.2 Conditions for a fire enclosure N/A 4.7.2.1 Parts requiring a fire enclosure 4.7.2.2 Parts not requiring a fire enclosure 4.7.3 Materials Pass 4.7.3.1 General N/A 4.7.3.2 Materials for fire enclosures 4.7.3.3 Materials for components and other parts outside fire enclosures 4.7.3.4 Materials for components and other parts inside fire All internal materials are rated enclosures V-2 or better or are mounted on a PWB rated V-1 or better. 4.7.3.5 Materials for air filter assemblies 4.7.3.6 Materials used in high-voltage components TRF No. IECEN60950_1C For building-in, fire enclosure to be provided in end product. N/A N/A For building-in, fire enclosure to be provided in end product. N/A N/A Pass N/A No high-voltage components. Underwriters Laboratories Inc. N/A Issue Date: 2010-05-19 Page 28 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass 5.1 Touch current and protective conductor current Pass 5.1.1 General Pass 5.1.2 Configuration of equipment under test (EUT) Pass 5.1.2.1 Single connection to an a.c. mains supply Pass 5.1.2.2 Redundant multiple connections to an a.c. mains supply N/A 5.1.2.3 Simultaneous multiple connections to an a.c. mains supply N/A 5.1.3 Test circuit Single phase equipment intended only for connection to star TN system. Pass 5.1.4 Application of measuring instrument Tested using D.1 measuring instrument. Pass 5.1.5 Test procedure Pass 5.1.6 Test measurements Pass Supply voltage (V) ............................................. : 264V - Measured touch current (mA) ............................. : Max. 1.5 mA (with switch "e" open) Max. 0.18mA (with switch "e" closed) - Max. allowed touch current (mA) ........................ : 3.5mA (with switch "e" open) 0.25mA (with switch "e" closed) - Measured protective conductor current (mA) ....... : -- - Max. allowed protective conductor current (mA) .. : -- - 5.1.7 Equipment with touch current exceeding 3,5 mA N/A 5.1.7.1 General............................................................. : N/A 5.1.7.2 Simultaneous multiple connections to the supply N/A 5.1.8 Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks N/A 5.1.8.1 Limitation of the touch current to a telecommunication network or to a cable distribution system N/A 5.1.8.2 Supply voltage (V) ............................................. : - Measured touch current (mA) ............................. : - Max. allowed touch current (mA) ........................ : - Summation of touch currents from TRF No. IECEN60950_1C Underwriters Laboratories Inc. N/A Issue Date: 2010-05-19 Page 29 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict telecommunication networks a) EUT with earthed telecommunication ports...... : N/A b) EUT whose telecommunication ports have no reference to protective earth N/A 5.2 Electric strength 5.2.1 General (see appended table 5.2) Pass 5.2.2 Test procedure No insulation breakdown detected during the test. Pass TRF No. IECEN60950_1C Pass Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 30 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test 5.3 Abnormal operating and fault conditions 5.3.1 Protection against overload and abnormal operation (see appended table 5.3) 5.3.2 Motors Fan motor evaluated as part of component evaluation. N/A 5.3.3 Transformers Transformers are constructed in accordance with the applicable Clause and Annex C. Pass 5.3.4 Functional insulation.......................................... : Functional insulation complies with the requirement (c). Pass 5.3.5 Electromechanical components N/A 5.3.6 Audio amplifiers in ITE ....................................... : N/A 5.3.7 Simulation of faults See table 5.3 5.3.8 Unattended equipment The equipments do not have any thermostats, temperature limiters, or thermal cut-outs which functioned during the Heating Test. N/A 5.3.9 Compliance criteria for abnormal operating and fault conditions No fire, emission of molten metal or deformation was noted during the tests. Electric Strength tests performed after abnormal and fault tests. Pass 5.3.9.1 During the tests No fire, emission of molten metal or deformation was noted during the tests. Pass 5.3.9.2 After the tests Electric Strength tests performed after abnormal and fault tests. Pass TRF No. IECEN60950_1C Result - Remark Verdict Pass Underwriters Laboratories Inc. Pass Pass Issue Date: 2010-05-19 Page 31 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 6 CONNECTION TO TELECOMMUNICATION NETWORKS N/A 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment N/A 6.1.1 Protection from hazardous voltages N/A 6.1.2 Separation of the telecommunication network from earth N/A 6.1.2.1 Requirements N/A Supply voltage (V) ............................................. : - Current in the test circuit (mA)............................ : - 6.1.2.2 Exclusions ........................................................ : N/A 6.2 Protection of equipment users from overvoltages on telecommunication networks N/A 6.2.1 Separation requirements N/A 6.2.2 Electric strength test procedure N/A 6.2.2.1 Impulse test N/A 6.2.2.2 Steady-state test N/A 6.2.2.3 Compliance criteria N/A 6.3 Protection of the telecommunication wiring system from overheating N/A Max. output current (A) ...................................... : - Current limiting method...................................... : - 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS N/A 7.1 General N/A 7.2 Protection of cable distribution system servi ce persons, and users of other equipment connected to the system, from hazardous voltages in the equipment N/A 7.3 Protection of equipment users from overvoltages on the cable distribution system N/A 7.4 Insulation between primary circuits and cable distribution systems N/A 7.4.1 General N/A 7.4.2 Voltage surge test N/A 7.4.3 Impulse test N/A TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 32 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE N/A A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see 4.7.3.2) N/A A.1.1 Samples ........................................................... : - Wall thickness (mm) .......................................... : - A.1.2 Conditioning of samples; temperature (°C) .......... : N/A A.1.3 Mounting of samples .......................................... : N/A A.1.4 Test flame (see IEC 60695-11-3) N/A Flame A, B, C or D ............................................ : N/A A.1.5 Test procedure N/A A.1.6 Compliance criteria N/A Sample 1 burning time (s) .................................. : - Sample 2 burning time (s) .................................. : - Sample 3 burning time (s) .................................. : - A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see 4.7.3.2 and 4.7.3.4) A.2.1 Samples, material.............................................. : - Wall thickness (mm) .......................................... : - A.2.2 Conditioning of samples; temperature (°C) .......... : N/A A.2.3 Mounting of samples .......................................... : N/A A.2.4 Test flame (see IEC 60695-11-4) N/A Flame A, B or C................................................. : N/A - A.2.5 Test procedure N/A A.2.6 Compliance criteria N/A A.2.7 Sample 1 burning time (s) .................................. : - Sample 2 burning time (s) .................................. : - Sample 3 burning time (s) .................................. : - Alternative test acc. to IEC 60695-11-5, cl. 5 and 9 N/A Sample 1 burning time (s) .................................. : - Sample 2 burning time (s) .................................. : - Sample 3 burning time (s) .................................. : - A.3 Hot flaming oil test (see 4.6.2) N/A A.3.1 Mounting of samples N/A A.3.2 Test procedure N/A TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 33 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict A.3.3 Compliance criterion N/A B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and 5.3.2) N/A B.1 General requirements N/A Position............................................................. : - Manufacturer..................................................... : - Type................................................................. : - Rated values ..................................................... : - B.2 Test conditions N/A B.3 Maximum temperatures N/A B.4 Running overload test N/A B.5 Locked-rotor overload test N/A Test duration (days)........................................... : - Electric strength test: test voltage (V).................. : - B.6 Running overload test for d.c. motors in secondary circuits N/A B.6.1 General N/A B.6.2 Test procedure N/A B.6.3 Alternative test procedure N/A B.6.4 Electric strength test; test voltage (V).................. : N/A B.7 Locked-rotor overload test for d.c. motors in secondary circuits N/A B.7.1 General N/A B.7.2 Test procedure N/A B.7.3 Alternative test procedure N/A B.7.4 Electric strength test; test voltage (V).................. : N/A B.8 Test for motors with capacitors N/A B.9 Test for three-phase motors N/A B.10 Test for series motors N/A Operating voltage (V)......................................... : TRF No. IECEN60950_1C Underwriters Laboratories Inc. - Issue Date: 2010-05-19 Page 34 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark C ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3) Verdict Pass Position............................................................. : See appended table 1.5.1. - Manufacturer..................................................... : See appended table 1.5.1. - Type................................................................. : See appended table 1.5.1. - Rated values ..................................................... : See appended table 1.5.1. - Method of protection.......................................... : protection by regulating network - C.1 Overload test See appended table 5.3. Pass C.2 Insulation (see appended table 5.2) Pass Protection from displacement of windings............ : Min. 3mm wide margin tape provided on both sides of each winding in Transformer T1. Min. 3.3mm wide margin tape provided on both sides of each winding in Transformer T900. Pass D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) Pass D.1 Measuring instrument Pass D.2 Alternative measuring instrument N/A E ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13) N/A F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) TRF No. IECEN60950_1C Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 35 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES N/A G.1 Clearances N/A G.1.1 General N/A G.1.2 Summary of the procedure for determining minimum clearances N/A G.2 Determination of mains transient voltage (V) N/A G.2.1 AC mains supply ............................................... : N/A G.2.2 Earthed d.c. mains supply .................................. : N/A G.2.3 Unearthed d.c. mains supply .............................. : N/A G.2.4 Battery operation............................................... : N/A G.3 Determination of telecommunication network transient voltage (V) :......................................... : N/A G.4 Determination of required withstand voltage (V) N/A G.4.1 Mains transients and internal repetitive peaks ..... : N/A G.4.2 Transients from telecommunication networks ...... : N/A G.4.3 Combination of transients N/A G.4.4 Transients from cable distribution systems N/A G.5 Measurement of transient voltages (V) N/A G.6 Determination of minimum clearances ................ : N/A H ANNEX H, IONIZING RADIATION (see 4.3.13) N/A J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6) N/A Metal(s) used .................................................... : Aluminum TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict - Issue Date: 2010-05-19 Page 36 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test K ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8) Pass K.1 Making and breaking capacity Pass K.2 Thermostat reliability; operating voltage (V)......... : N/A K.3 Thermostat endurance test; operating voltage (V) : N/A K.4 Temperature limiter endurance; operating voltage The two thermostats are UL (V).................................................................... : R/C and was tested for 10000 cycles of operation during the component evaluation. K.5 Thermal cut-out reliability K.6 Stability of operation L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2) L.1 Typewriters N/A L.2 Adding machines and cash registers N/A L.3 Erasers N/A L.4 Pencil sharpeners N/A L.5 Duplicators and copy machines N/A L.6 Motor-operated files N/A L.7 Other business equipment TRF No. IECEN60950_1C Result - Remark The two thermostats are is UL R/C and was tested for 10000 cycles of operation during the component evaluation. Verdict Pass N/A (see appended table 5.3) Maximum rating load. Underwriters Laboratories Inc. Pass Pass Pass Issue Date: 2010-05-19 Page 37 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) N/A M.1 Introduction N/A M.2 Method A N/A M.3 Method B N/A M.3.1 Ringing signal N/A M.3.1.1 Frequency (Hz) ................................................. : - M.3.1.2 Voltage (V)........................................................ : - M.3.1.3 Cadence; time (s), voltage (V) ............................ : - M.3.1.4 Single fault current (mA) .................................... : - M.3.2 Tripping device and monitoring voltage ............... : N/A M.3.2.1 Conditions for use of a tripping device or a monitoring voltage N/A M.3.2.2 Tripping device N/A M.3.2.3 Monitoring voltage (V)........................................ : N/A N ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1, 7.3.2, 7.4.3 and Clause G.5) N/A N.1 ITU -T impulse test generators N/A N.2 IEC 60065 impulse test generator N/A P ANNEX P, NORMATIVE REFERENCES Pass Q ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1) Pass a) Preferred climatic categories .......................... : The VDR's used are UL R/C components. Pass b) Maximum continuous voltage ......................... : VDR's used are rated for the application Pass c) Pulse current ................................................. : The VDR's used are UL R/C components. Pass TRF No. IECEN60950_1C Result - Remark Underwriters Laboratories Inc. Verdict Issue Date: 2010-05-19 Page 38 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES N/A R.1 Minimum separation distances for unpopulated coated printed boards (see 2.10.6.2) N/A R.2 Reduced clearances (see 2.10.3) N/A S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3) N/A S.1 Test equipment N/A S.2 Test procedure N/A S.3 Examples of waveforms during impulse testing N/A T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2) N/A ........................................................................ : IPX0 U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see 2.10.5.4) ........................................................................ : Verdict - N/A - V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) Pass V.1 Introduction Pass V.2 TN power distribution systems Pass TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 39 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test W ANNEX W, SUMMATION OF TOUCH CURRENTS N/A W.1 Touch current from electronic circuits N/A W.1.1 Floating circuits N/A W.1.2 Earthed circuits N/A W.2 Interconnection of several equipments N/A W.2.1 Isolation N/A W.2.2 Common return, isolated from earth N/A W.2.3 Common return, connected to protective earth N/A X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) Pass X.1 Determination of maximum input current Pass X.2 Overload test procedure Pass Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3) N/A Y.1 Test apparatus .................................................. : N/A Y.2 Mounting of test samples ................................... : N/A Y.3 Carbon-arc light-exposure apparatus .................. : N/A Y.4 Xenon-arc light-exposure apparatus ................... : N/A Z ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2) AA ANNEX AA, MANDREL TEST (see 2.10.5.8) TRF No. IECEN60950_1C Result - Remark Underwriters Laboratories Inc. Verdict Pass N/A Issue Date: 2010-05-19 Page 40 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict 1.5.1 TABLE: list of critical components Object/part No. Manufacturer/ trademark type/model technical data Product Category CCN(s) Required Marks of Conformity Supplement ID Enclosure cover Various Various -- -- 4-01 Enclosure base various various -- -- 4-01 Vent Openings (Side Chassis) Various Various -- -- Fan Opening (Front Chassis) Various Various -- -- Fan Sanyo Denki Co Ltd 109P0412K3023 GPWV2 UL Fan (Alternate) Sanyo Denki Co Ltd 109P0412J3023 GPWV2 UL Fan (Alternate) Sanyo Denki Co Ltd 109P0412G3023 Aluminium, min. 1.2 mm thick, secured to enclosure base by screws. Measured overall 211 by 100.6 by 10 mm. Aluminum, min. 2.0 mm thick. Measured overall 218 by 105 by 40 mm. Four rectangular openings each measured overall 6.9 by 2.5 mm on both Left and Right Chassis. One additional slot opening measured overall 10 by 4.0mm on left Chassis Measured overall 38 mm dia., consists of 3 concentric slot rings, each measured max. 10 mm wide. Rated 12Vdc, 0.55A, 21 CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. Rated 12Vdc, 0.35A, 16.3 CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. Rated 12Vdc, 0.31A, 14.8 GPWV2 UL TRF No. IECEN60950_1C Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 41 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Fan (Alternate) MINEBEA MOTOR MFG CORP Fan (Alternate) MINEBEA MOTOR MFG CORP Fan (Alternate) MINEBEA MOTOR MFG CORP Fan (Alternate) Delta Electronics Inc Insulating Various Tubing/Sleeving (Applied on leads of thermal switch on L100 except secondary portion and TRF No. IECEN60950_1C Verdict CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. 1611RL-04W-B50 Rated 12Vdc, 0.22A, 10.5 CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. 1611RL-04W-B60 Rated 12Vdc, 0.35A, 13.7 CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. 1611RL-04W-B70 Rated 12Vdc, 0.47A, 15.8 CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. FFB0412VHN Rated 12Vdc, 0.16A, 15.79 CFM. Outward airflow orientation. Secured to the front Chassis by screws. Fan leads provided with min. 0.4mm thick tubing. Varous FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; minimum 105 degree C, minimum 300 V. Mininum 0.4 mm thick Underwriters Laboratories Inc. GPWV2 UL GPWV2 UL GPWV2 UL GPWV2 UL UZFT2, YDPU2, YDTU2 UL Issue Date: 2010-05-19 Page 42 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark fan leads) Insulating Various Tubing/Sleeving (Applied on other components) Varous Verdict FEP, PTFE, PVC, TFE, neoprene, or marked VW-1; minimum 105 degree C, minimum 300 V. Min. 300V, min. 80 degree C. VW-1 Min. 60V, min. 80 degree C. VW-1 300 V ac, 20 A, 120 degree C. Rated minimum V-1, minimum 105 degree C. UZFT2, YDPU2, YDTU2 UL AVLV2, AVLV8 UL AVLV2, AVLV8 UL XCFR2 ZPMV2 UL UL ZPMV2 UL JDYX, JDYX7 JDYX2, JDYX8 UL UL Internal Wiring (Primary, for thermal switches) Internal Wiring (SELV, for fan leads) Terminal Block (TB1) Printed Wiring Boards (Main board and Small secondary board) Control Board (optional) Various Various Various Various Switchlab Various T35 series Various Various Various Fuse (FS1) Fuse (FS1) (Alternate) Various CONQUER ELECTRONICS CO LTD LITTELFUSE INC BEL FUSE INC Various UBM Rated minimum V-1, minimum 105 degree C. F8A, 250Vac F8A, 250Vac 216 5HF F8A, 250Vac F8A, 250Vac JDYX2, JDYX8 JDYX2, JDYX8 UL UL WALTER ELECTRONIC CO LTD Various FSC F8A, 250Vac JDYX2, JDYX8 UL Various ARCOTRONICS SPA R.46, R.49 EPCOS ELECTRONIC B3292 series Rated max. 470 k ohms, -minimum 1/4 W. Each rated max. 1 uF, FOWX2 minimum 250 Vac, 110 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, FOWX2 minimum 250 Vac, 105 degree Fuse (FS1) (Alternate) Fuse (FS1) (Alternate) Fuse (FS1) (Alternate) Bleeder Resistors (R1, R2) X-Capacitors (C1, C2) (Optional) X-Capacitors (C1, C2) (Optional) (Alternate) TRF No. IECEN60950_1C Underwriters Laboratories Inc. -UL UL Issue Date: 2010-05-19 Page 43 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark COMPONENTS S A X-Capacitors (C1, C2) (Optional) (Alternate) ISKRA KNB1530 KONDENZATORJI D D X-Capacitors (C1, C2) (Optional) (Alternate) ISKRA KNB1560 KONDENZATORJI D D X-Capacitors (C1, C2) (Optional) (Alternate) LIOW GU ELECTRONICS INDUSTRY CO LTD GS-L X-Capacitors (C1, C2) (Optional) (Alternate) PILKOR ELECTRONICS CO LTD PCX2 335 X-Capacitors (C1, C2) (Optional) (Alternate) PILKOR ELECTRONICS CO LTD PCX2 335M X-Capacitors (C1, C2) (Optional) (Alternate) PILKOR ELECTRONICS CO LTD PCX2 337 X-Capacitors (C1, C2) ULTRA TECH XIPHI HQX TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 125 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 85 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL Issue Date: 2010-05-19 Page 44 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark (Optional) (Alternate) ENTERPRISE CO LTD X-Capacitors (C1, C2) (Optional) (Alternate) VISHAY CAPACITORS BELGIUM N V 339 X-Capacitors (C1, C2) (Optional) (Alternate) CHENG TUNG INDUSTRIAL CO LTD CTX X-Capacitors (C1, C2) (Optional) (Alternate) SHINY SPACE ENTERPRISE CO LTD SX1 Y-Capacitors (C3, C4, C23, C24, C30) (Optional) MURATA MFG CO LTD KX, KH Y-Capacitors (C3, C4, C23, C24, C30) (Optional) (Alternate) WALSIN TECHNOLOGY CORP AH, AC Y-Capacitors (C3, C4, C23, C24, C30) (Optional) (Alternate) TDK-EPC CORP CD, CS TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict minimum 250 Vac, 100 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 105 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 1 uF, minimum 250 Vac, 100 degree C. Class X1 or X2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Each rated max. 4700 pF, minimum 250 Vac, 125 degree C. Class Y1 or Y2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. FOWX2 UL FOWX2 UL FOWX2 UL FOWX2, FOWX8 UL FOWX2, FOWX8 UL FOWX2, FOWX8 UL Issue Date: 2010-05-19 Page 45 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Y-Capacitors (C3, C4, C23, C24, C30) (Optional) (Alternate) WELSON INDUSTRIAL CO LTD WD, KL Varistor (ZNR1) (Optional) THINKING ELECTRONIC INDUSTRIAL CO LTD JOYIN CO LTD TVR10471-D, TVR14471-D Varistor (ZNR1) (Optional) (Alternate) Varistor (ZNR1) (Optional) (Alternate) Varistor (ZNR1) (Optional) (Alternate) Thermistor (RTH1) (Optional) Relay (RY1) Relay (RY1) (Alternate) Relay (RY1) (Alternate) Rectifier (BD1) Electrolytic Capacitor (C5) CENTRA SCIENCE CORP NIPPON CHEMICON CORP Various Each rated max. 4700 pF, FOWX2, FOWX8 minimum 250 Vac, 125 degree C. Class Y1 or Y2. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. 300Vac VZCA2 UL 14S471K, 14N471K CNR-14D471K 300Vac VZCA2 UL 300Vac VZCA2 UL TNR14V-471K 300Vac VZCA2 UL Various Rated minimum 2 A, maximum 20 ohms at 25 degree C Rated 10 A, 277Vac. -- -- NRNT2 UL OJESS112HMF, OJESH112HMF Rated 10A, 250V. NRNT2 UL OJESS112LMH, OJESH112LMH Rated 8A, 250V. NRNT2 UL Various Rated minimum 2A, minimum QQQX2 600 V, minimum 100 degree C, minimum isolation voltage 1500 Vac Integral pressure relief, rated -330 uF, minimum 400 V, minimum 85 degree C. UL SONG CHUAN PRECISION CO LTD TYCO ELECTRONICS (SHENZHEN) CO. LTD TYCO ELECTRONICS (SHENZHEN) CO. LTD Various 835-1A -B-C Various Various TRF No. IECEN60950_1C Verdict Underwriters Laboratories Inc. UL -- Issue Date: 2010-05-19 Page 46 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Transistors (Q1, Q2, Q3, Various Q4) Line Filters (LF1, LF2) Various (Optional) Core (LF1, LF2) Various Various Coil (LF1, LF2) PFC choke (L3) Various Various Various TR-934 Core (L3) Various Various Coil (L3) Choke (T2) (Optional) Various Various Various TR-435 Choke (T2) (Optional) (Alternate) Core (T2) Various TR-852 Various Various Coil (T2) Triple Insulated Winding Wire (T2) Optical Isolators (U2, U3, U4, U901) (U4 optional; U901 on optional Control Board) Optical Isolators (U2, U3, U4, U901) (U4 optional; U901 on optional Control Board) Optical Isolators (U2, U3, Various Various Various Various Sharp Corp., Electronic Components Group Verdict Rated 12A-22 A, minimum 500 V. Open type construction. Rated 130 degree C. Ferrite, measured overall 22 mm OD by 14 mm ID by 8 mm wide. Rated minimum 130 degree C. Open type construction. Rated 130 degree C. Ferrite, measured overall 26.92 mm OD by 14.73 mm ID by 18 mm wide. Rated minimum 130 degree C. Open type construction. Rated 130 degree C. Open type construction. Rated 130 degree C. Ferrite, measured overall 13 mm OD by 7 mm ID by 5 mm wide. Rated minimum 130 degree C. Rated minimum 130 degree C. -- -- -- -- -- -- OBMW2 -- UL -- -- -- OBMW2 -- UL -- 7-09 -- -- 7-10 -- -- OBMW2 OBJT2 UL UL PC123 Minimum 5000Vac isolation. Double protection. FPQU2 UL Lite-On Technology Corp. LTV-817 Minimum 5000Vac isolation. Double protection. FPQU2 UL COSMO K1010 Minimum 5000Vac isolation. FPQU2 UL TRF No. IECEN60950_1C TR-548 Various Underwriters Laboratories Inc. 7-07 7-08 Issue Date: 2010-05-19 Page 47 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test U4, U901) (U4 optional; U901 on optional Control Board) Bridging Capacitor (C31) (Optional) Result - Remark ELECTRONICS CORP MURATA MFG CO LTD Double protection. KX Bridging Capacitor (C31) WALSIN (Optional) (Alternate) TECHNOLOGY CORP AH Briding Capacitor (C31) (Optional) (Alternate) CD TDK-EPC CORP Bridging Capacitor (C31) WELSON (Optional) (Alternate) INDUSTRIAL CO LTD WD Transformer (T1) TF-2107 (for Y=3.3), TF-2108 (for Y=5), TF 2109 (for Y=7.5), TF-2110 (for Y=12), TF-2111 (for Y=15), TF2112 (for Y=24), TF-2113 (for Y=36), TF-2114 (for Y=48) Jet Signal Industries Co., Ltd. TRF No. IECEN60950_1C Verdict Underwriters Laboratories Inc. Rated max. 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Rated max. 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Rated max. 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Rated max. 2200 pF, minimum 250 Vac, 125 degree C. Class Y1. (Meet IEC 60384-14). The damp heat test duration in 21 days minimum. Class B (130 degree C) Insulation System, Type SBI4.2. FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL OBJY2 UL 7-01 Issue Date: 2010-05-19 Page 48 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Transformer (T1) (Alternate) Elytone Electronic Co., Ltd. Transformer (T1) (Alternate) Long Sail Electronic Co., Ltd. Core (T1) Various TF-2107 (for Y=3.3), TF-2108 (for Y=5), TF 2109 (for Y=7.5), TF-2110 (for Y=12), TF-2111 (for Y=15), TF2112 (for Y=24), TF-2113 (for Y=36), TF-2114 (for Y=48) TF-2107 (for Y=3.3), TF-2108 (for Y=5), TF 2109 (for Y=7.5), TF-2110 (for Y=12), TF-2111 (for Y=15), TF2112 (for Y=24), TF-2113 (for Y=36), TF-2114 (for Y=48) Various Coil (T1) Primary Copper foil (T1) Various Various Various Various Bobbin (T1) Sumitomo Bakelite Co Ltd. PM-9820 Bobbin (T1) (Alternate) Sumitomo Bakelite PM-9630 TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict Class B (130 degree C) Insulation System, Type SBI4.2. OBJY2 UL 7-02 Class B (130 degree C) Insulation System, Type SBI4.2. OBJY2 UL 7-03 Ferrite, overall 45 by 39 by 13 mm. Rated minimum 130 degree C. Measured overall 20 mm by 0.025 mm thick. Provided with insulation tape minimum 3.0 mm from both edge of copper foil. Phenolic, rated V-0, 150 degree C, minimum 0.71 mm thick. Phenolic, rated V-0, 150 -- -- OBMW2 -- UL -- QMFZ2 UL QMFZ2 UL Issue Date: 2010-05-19 Page 49 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict Co Ltd. Insulating Tape (T1) Insulating Tape (T1) (Alternate) Insulating Tape (T1) (Alternate) Varnish (T1) Varnish (T1) (Alternate) Varnish (T1) (Alternate) Varnish (T1) (Alternate) Varnish (T1) (Alternate) Tubing (T1) Tubing (T1) (Alternate) Margin Tape (T1) Margin Tape (T1) (Alternate) Margin Tape (T1) (Alternate) degree C, minimum 0.71 mm thick. 3M Co. 1350F-1, 1350T-1 Polyester tape, rated 130 degree C. Symbio Inc. 35660Y, 35660 Polyester tape, rated 130 degree C. Bondtec Pacific Co., 370S Polyester tape, rated 130 Ltd. degree C. John C Dolph Co. BC-346A Rated minimum 130 degree C. Hitachi Chemical Co., WP-2952F-2G Rated minimum 130 degree C. Ltd. Elantas Electrical 468-2(x) Rated minimum 130 degree C. Insulation Elantas Pdg Inc (Ripley Resin Engineering Co., Inc.) KYOCERA TVB-2180T++ Rated minimum 130 degree C. CHEMICAL CORP PD V1630FS Rated minimum 130 degree C. GEORGE/VIKING Great Holding TFL, TFT Rated minimum 200 degree C. Industrial Co., Ltd. Provided on all exit leads. Zeus Industrial TFE-TW-300, Rated minimum 200 degree C. Products Inc. TFE-LW-150 Provided on all exit leads. 3M Co. 44D-A, 44T-A Polyester tape, rated 130 degree C, measured min. 3.0 mm width on both side of bobbin. Symbio Inc. 35661, 35660, Polyester tape, rated 130 35660Y degree C, measured min. 3.0 mm width on both side of bobbin. Bondtec Pacific Co., 201 Polyester tape, rated 130 Ltd. degree C, measured min. 3.0 mm width on both side of TRF No. IECEN60950_1C Underwriters Laboratories Inc. OANZ2 UL OANZ2 UL OANZ2 UL OBOR2 OBOR2 UL UL OBOR2 UL OBOR2 UL OBOR2 UL YDPU2 UL YDPU2 UL OANZ2 UL OANZ2 UL OANZ2 UL Issue Date: 2010-05-19 Page 50 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Transformer (T900) (Provided when Optional Control Board is provided) Transformer (T900) (Provided when Optional Control Board is provided) (Alternate) Transformer (T900) (Provided when Optional Control Board is provided) (Alternate) Core (T900) Long Sail Electronic Co., Ltd. TF-1593 Jet Signal Industries Co., Ltd. TF-1593 Elytone Electronic Co., Ltd. TF-1593 Various Various Bobbin (T900) Sumitomo Bakelite Co., Ltd. Bobbin (T900) (Alternate) Coils (T900) Primary copper foil (T900) Insulating Tape (T900) Sumitomo Bakelite Co., Ltd. Various Various Insulating Tape (T900) (Alternate) Insulating Tape (T900) (Alternate) Margin Tape (T900) Symbio Inc. Margin Tape (T900) Symbio Inc. 3M Co. Bondtec Pacific Co., Ltd. 3M Co. TRF No. IECEN60950_1C Verdict bobbin. Class B (130 degree C) Insulation System, Type SBI4.2. OBJY2 UL 7-06 Class B (130 degree C) Insulation System, Type SBI4.2. OBJY2 UL 7-04 Class B (130 degree C) Insulation System, Type SBI4.2. OBJY2 UL 7-05 -- -- QMFZ2 UL QMFZ2 UL OBMW2 -- UL -- OANZ2 UL OANZ2 UL OANZ2 UL OANZ2 UL OANZ2 UL Ferrite, measured overall 15 by 15 by 4.65 mm. PM-9820 Phenolic. Rated V-0, 150 degree C, minimum 0.71 mm thick. PM-9630 Phenolic. Rated V-0, 150°C, minimum 0.71 mm thick. Various Rated minimum 130 degree C. Various Measured overall 8 mm by 0.025 mm thick. 1350F-1, 1350T-1 Polyester tape, rated 130 degree C. 35660, 35660Y Polyester tape, rated 130 degree C. 370S Polyester tape, rated 130 degree C. 44D-A, 44T-A Polyester tape, rated 130 degree C, measured min. 3.3 mm width on both side of bobbin. 35661 Polyester tape, rated 130 Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 51 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark (Alternate) Margin Tape (T900) (Alternate) Bondtec Pacific Co., Ltd. 201 Varnish (T900) Varnish (T900) (Alternate) Varnish (T900) (Alternate) John C Dolph Co. Hitachi Chemical Co., Ltd. Elantas Electrical Insulation Elantas PDG Inc. Kyocera Chemical Corp. PD George / Vinking BC-346A WP-2952F-2G Verdict degree C, measured min. 3.3 mm width on both side of bobbin. Polyester tape, rated 130 degree C, measured min. 3.3 mm width on both side of bobbin. Rated minimum 130 degree C. Rated minimum 130 degree C. OANZ2 UL OBOR2 OBOR2 UL UL 468-2-7, 468-2, 486-2FC Rated minimum 130 degree C. OBOR2 UL TVB-2180T Rated minimum 130 degree C. OBOR2 UL V1630FS Rated minimum 130°C. OBOR2 UL Great Holding Industrial Co., Ltd. Zeus Industrial Products Inc. Seki Controls Co., Ltd. TFL, TFT YDPU2 UL YDPU2 UL XAPX2 UL Leads of Thermal Switches Various Various AVLV2 UL Heat Sink (HS1) Various Various Rated minimum 200 degree C. Provided on all exit leads. Rated minimum 200 degree C. Provided on all exit leads. Two provided. Rated 125/250 Vac, 70-130 degree C. Provided with lead wires and connected to connectors TSW1 and TSW2. One secured on L100 choke and the other one secured on HS1 above Q1 and Q2 via a Heat Sink by a screw. Minimum 300 V, PVC insulated, minimum 0.2 mm thick minimum 22 AWG, 125 deg C, marked with VW-1. Copper, minimum 1.5 mm Varnish (T900) (Alternate) Varnish (T900) (Alternate) Tubing (T900) Tubing (T900) (Alternate) Thermal Switches TRF No. IECEN60950_1C TFE-TW-300, TFE-LW-150 ST-22 Underwriters Laboratories Inc. -- -- 4-02 Issue Date: 2010-05-19 Page 52 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Considered earthed Heat Sink (HS2) Considered earthed Various Various Heat Sink (HS3) Considered secondary Various Various Heat Sink (HS4) Considered earthed Various Various Heat Sink (for Thermal Switch) Various Various Insulation Sheets (Provided between PWBs traces and bottom Chassis) Insulation Sheets (Provided between PWBs traces and bottom Chassis) (Alternate) Insulation Sheets (Provided on Top chassis above C5 and L3) Insulation Sheets (Provided on Top chassis above C5 and L3) (Alternate) Insulation Sheets (Provided on Top chassis near L100) Formex,Div of ILLIONIS TOOL WORKS INC Formex GK Sabic Innovative Plastics FR700 Formex,Div of ILLIONIS TOOL WORKS INC Formex GK Sabic Innovative Plastics FR700 Formex,Div of ILLIONIS TOOL WORKS INC Formex GK TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict thick. See Enclosure for detailed dimensions. Aluminum, minimum 1.5 mm thick. See Enclosure for detailed dimensions. Copper, minimum 1.0 mm thick. See Enclosure for detailed dimensions. Copper, minimum 1.5 mm thick. See Enclosure for detailed dimensions. Aluminum, minimum 1.5mm thick. See enclosure for detailed dimensions Mylar, minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. See Enclosure for detailed dimensions. Mylar, minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. See Enclosure for detailed dimensions. Mylar, minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. See Enclosure for detailed dimensions. Mylar, minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. See Enclosure for detailed dimensions. Mylar, minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. See Enclosure for detailed dimensions. -- -- 4-03 -- -- 4-04 -- -- 4-05 -- -- 4-10 QMFZ2 UL 4-13 QMFZ2 UL QMFZ2 UL QMFZ2 UL QMFZ2 UL 4-12 4-11 Issue Date: 2010-05-19 Page 53 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Insulation Sheets (Provided on Top chassis near L100) (Alternate) Silicone Rubber Insulators (Provided for Q1, Q2, Q3, Q4, D1) Silicone Rubber Insulators (Provided for Q1, Q2, Q3, Q4, D1) (Alternate) Adhesive Glue (Provided for C10, T2, Thermal Switches, fly lead FL1A of T900) Label Result - Remark Sabic Innovative Plastics FR700 SIX PHASE CO LTD 610 PIONEER MATERIAL PRECISION TECH PMP-P-400, PMP-P-100 Various Various TRF No. IECEN60950_1C Verdict Mylar, minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. See Enclosure for detailed dimensions. Minimum V-2, minimum 105 degree C, minimum 0.2 mm thick. Minimum V-2, minimum 150 degree C, minimum 0.2 mm thick. QMFZ2 UL QMFZ2 UL QMFZ2 UL Various Rated minimum V-2, min. 105 degree C QMFZ2 UL Various Rated minimum 70 degree C. PGDQ2 UL Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 54 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test 1.6.2 TABLE: electrical data (in normal conditions) U (V) Model HRPG450-5 90 100 240 254 264 90 100 240 254 264 Model HRPG450-12 90 100 240 254 264 90 100 240 254 264 Model HRPG450-24 90 100 240 254 264 90 100 240 254 264 Model HRPG450-48 90 100 240 I (A) Result - Remark I rated (A) P (W) Fuse # Verdict Pass I fuse (A) condition/status -- -- -- -- -- -- 6.36 5.64 2.29 2.17 2.09 6.37 5.67 2.30 2.18 2.10 -- -6.0 6.0 ---6.0 6.0 ---- 567 562 539 539 539 570 565 540 539 539 -- FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 -- 6.36 5.64 2.29 2.17 2.09 6.37 5.67 2.30 2.18 2.10 -- +5V/90A / 50Hz +5V/90A / 50Hz +5V/90A / 50Hz +5V/90A / 50Hz +5V/90A / 50Hz +5V/90A / 60Hz +5V/90A / 60Hz +5V/90A / 60Hz +5V/90A / 60Hz +5V/90A / 60Hz -- 6.06 5.38 2.19 2.08 2.01 6.07 5.40 2.20 2.09 2.02 -- -6.0 6.0 ---6.0 6.0 ---- 543 537 515 515 514 543 538 516 515 514 -- FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 -- 6.06 5.38 2.19 2.08 2.01 6.07 5.40 2.20 2.09 2.02 -- +12V/37.5A/ 50Hz +12V/37.5A/ 50Hz +12V/37.5A/ 50Hz +12V/37.5A/ 50Hz +12V/37.5A/ 50Hz +12V/37.5A/ 60Hz +12V/37.5A/ 60Hz +12V/37.5A/ 60Hz +12V/37.5A/ 60Hz +12V/37.5A/ 60Hz -- 6.02 5.34 2.18 2.06 1.99 6.03 5.35 2.18 2.07 2.00 -- -6.0 6.0 ---6.0 6.0 ---- 539 532 510 510 510 540 533 511 511 510 -- FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 FS1 -- 6.02 5.34 2.18 2.06 1.99 6.03 5.35 2.18 2.07 2.00 -- +24V/18.8A/ 50Hz +24V/18.8A/ 50Hz +24V/18.8A/ 50Hz +24V/18.8A/ 50Hz +24V/18.8A/ 50Hz +24V/18.8A / 60Hz +24V/18.8A / 60Hz +24V/18.8A / 60Hz +24V/18.8A / 60Hz +24V/18.8A / 60Hz -- 6.00 5.32 2.16 -6.0 6.0 536 529 507 FS1 FS1 FS1 6.00 5.32 2.16 +48V/9.5A/ 50Hz +48V/9.5A/ 50Hz +48V/9.5A/ 50Hz TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 55 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause 254 264 90 100 240 254 264 Requirement + Test 2.05 1.97 6.01 5.33 2.17 2.06 1.99 Result - Remark ---6.0 6.0 --- 507 507 536 530 507 508 507 FS1 FS1 FS1 FS1 FS1 FS1 FS1 2.05 1.97 6.01 5.33 2.17 2.06 1.99 Verdict +48V/9.5A/ 50Hz +48V/9.5A/ 50Hz +48V/9.5A / 60Hz +48V/9.5A / 60Hz +48V/9.5A / 60Hz +48V/9.5A / 60Hz +48V/9.5A / 60Hz supplementary information: Maximum Normal load: Loaded to output rating. 2.10.3 and 2.10.4 TABLE: clearance and creepage distance measurements Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) Required cl (mm) Pass cl (mm) Required cr (mm) cr (mm) (Measured on Main PWB) Line to Neutral before Fuse FS1 (FI) Under Fuse FS1 (BI) L and N trace to FG trace (RI) Between C31 Pri. to Sec Trace (RI) Under T1 (RI) -<420 -<250 -2.0 -2.7 -2.5 -2.7 <420 <420 <420 <250 <250 <250 2.0 4.0 4.0 7.4 5.0 6 2.5 5.0 5.0 7.4 5.0 8 480 <250 4.2 6 5.0 Under optical Isolator (U2, U3, U4) (RI) <420 <250 4.0 7.6 5.0 Optical Isolator Body (U2, U3, U4) (Measured on Control PWB)Under optical U901 Under T900 (Measured on product) C5 to Top Chassis (BI) <420 <250 4.0 6.6 5.0 6 (with PWB slots bypassed) 7.6 (with PWB slots bypassed) 6.6 -<420 456 -<420 -<250 303 -<250 -4.0 4.2 -2.0 -7.3 5.5 -2.5 -5.0 6.2 -2.5 (Measured on T1) -- -- -- -- -- TRF No. IECEN60950_1C Underwriters Laboratories Inc. -7.3 7.2 -N/A (no creepage path) Core is considered floating, maintains BI to primary and SI to secondary. Core is Issue Date: 2010-05-19 Page 56 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict Primary winding to secondary winding (RI) 480 <250 4.2 6 5.0 Primary winding to secondary terminals (RI) 480 <250 4.2 5.5 5.0 Secondary winding to primary terminal (RI) 480 <250 4.2 6.0 5.0 Secondary winding to core (SI) 480 <250 2.1 3.0 2.5 Secondary terminal to core (SI) 480 <250 2.1 8.6 2.5 Primary winding to core (BI) 480 <250 2.1 3.0 2.5 Primary terminal to core (BI) 480 <250 2.1 8.6 2.5 (Measured on T900) -- -- -- -- -- TRF No. IECEN60950_1C Underwriters Laboratories Inc. wrapped with two layers of Insulation Tape 6.0 (3.0mm margin tape is provided on both sides of each winding) 5.5 (measured min. 2.5mm from terminal pin to inner edge of bobbin) 6.0 (measured min. 3.0mm from terminal pin to inner edge of bobbin) 3.0 (margin tape) 8.6 (measured on bobbin) 3.0 (margin tape) 8.6 (measured on bobbin) Core is considered floating, maintains BI to primary and SI to secondary. Core is wrapped with Issue Date: 2010-05-19 Page 57 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict Primary winding to secondary winding (RI) 456 303 4.2 6.6 6.2 Primary winding to secondary terminals (RI) 456 303 4.2 6.7 6.2 Secondary winding to primary terminal (RI) 456 303 4.2 6.7 6.2 Secondary winding to core (SI) 456 303 2.1 3.3 3.1 Secondary terminal to core (SI) 456 303 2.1 6.7 3.1 Primary winding to core (BI) 456 303 2.1 3.3 3.1 Primary terminal to core (BI) 456 303 2.1 6.7 3.1 insulated tape. 6.6 (primary margin tape + secondary margin tape) 6.7 (bend around tape + 1.2 along bobbin surface) 6.7 (bend around tape + 1.2 along bobbin surface) 3.3 (margin tape) 6.7 (bobbin bottom terminals board) 3.3 (margin tape) 6.7 (bobbin bottom terminal board) supplementary information: 1) The following wiring is sleeved with tubing minimum 0.4 mm thick: DC fan leads, leads of thermal switch on L100 (except the portion on primary side) 2) The following components are sleeved: RTH1, D1, R4, R5, Q1, Q2, Q3, Q4 3) The following components were tested with 10N: T2, C31, C18, C5, L3 4) Slots are provided on both Main board and control board. See Enclosure PWBs layouts for details. 5) The following components are secured with adhesive: C10, T2, Thermal Switches, fly lead FL1A of T900. 6) Transformer (T900) core is entirely wrapped by two layers of insulation tape. 2.10.5 TABLE: distance through insulation measurements Distance through insulation (DTI) at/of: -- TRF No. IECEN60950_1C U peak (V) -- Urms (V) -- Underwriters Laboratories Inc. Pass Test voltage Required DTI (V) (mm) -- -- DTI (mm) -- Issue Date: 2010-05-19 Page 58 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict supplementary information: See Critical Component List 4.3.8 TABLE: Batteries N/A The tests of 4.3.8 are applicable only when appropriate battery data is not available. Is it possible to install the battery in a reverse polarity position? Non-rechargeable batteries Discharging Meas. current Rechargeable batteries Unintentional charging Manuf. specs. Charging Meas. current Discharging Manuf. specs. Meas. current Manuf. specs. Reversed charging Meas. current Manuf. specs. Max. current during normal operation Max. current during fault operation Test results: Verdict - Chemical leaks - Explosion of the battery - Emission of flame or expulsion of molten metal - Electric strength tests of equipment after completion of tests supplementary information: 4.5 TABLE: Thermal requirements Supply voltage (V) ..................................... : TRF No. IECEN60950_1C Pass See below See below Underwriters Laboratories Inc. See below See below -- — Issue Date: 2010-05-19 Page 59 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Ambient Tmin (°C) ..................................... : Ambient Tmax (°C) .................................... : See below See below See below See below Maximum measured temperature T of part/at: See below See below -- — -- — T (°C) Model HRPG-450-5 90V / 60Hz TB1 body C24 body ( Y-cap.) C1 body ( X-cap.) ZNR1 body LF1 coil C2 body ( X-cap.) LF2 coil C3 body ( Y-cap.) RY1 body PCB under RTH1 C30 body ( Y-cap.) HS near Q1 L3 coil C5 body (Bulk cap.) T2 coil HS near Q3 T1 Primary coil T1 secondary coil T1 Core C31 body (Bridging-cap.) U4 body (photocouple) L100 coil T900 top-side coil T900 bottom-side coil T900 core U901 body (photocouple) Metal ecclosure Ambient air Test time (h:m) Model HRPG-450-12 31.2 37.4 44.2 64.9 46.7 56.9 76.4 48.5 60.4 77.0 57.6 71.1 85.0 53.3 48.8 55.8 73.6 85.3 62.0 56.0 57.4 59.3 33.7 33.7 33.0 32.9 47.8 30.7 -90V / 60Hz TRF No. IECEN60950_1C See below See below Verdict 90V / 60Hz normali zed to 50 degree C ambien t 50.5 56.7 63.5 84.2 66.0 76.2 95.7 67.8 79.7 96.3 76.9 90.4 104.3 72.6 68.1 75.1 92.9 104.6 81.3 75.3 76.7 78.6 53.0 53.0 52.3 52.2 67.1 50.0 1:24 90V / 60Hz Underwriters Laboratories Inc. 264V / 60Hz 29.5 34.0 40.1 44.0 42.0 46.3 54.2 40.2 48.7 60.8 46.5 56.0 59.2 48.4 45.6 50.6 69.9 80.6 58.2 53.3 55.5 57.8 33.0 32.7 32.4 32.2 42.6 26.6 -264V / 60Hz allowed Tmax (°C) 264V / 60Hz normali zed to 50 degree C ambien t 52.9 57.4 63.5 67.4 65.4 69.7 77.6 63.6 72.1 84.2 69.9 79.4 82.6 71.8 69.0 74.0 93.3 104.0 81.6 76.7 78.9 81.2 56.4 56.1 55.8 55.6 66.0 50.0 1:13 264V / 60Hz - - - 120 85 85 85 130 85 130 125 105 105 125 105 130 85 130 105 110 110 110 125 100 105 110 110 110 100 70 --- Issue Date: 2010-05-19 Page 60 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark ZNR1 body C2 body ( X-cap.) LF2 coil PCB under RTH1 C30 body ( Y-cap.) HS near Q1 L3 coil T1 Primary coil T1 secondary coil T1 Core C31 body (Bridging-cap.) T900 top-side coil T900 bottom-side coil T900 core Metal ecclosure Ambient air Test time (h:m) Model HRPG-450-24 38.6 45.2 57.3 50.8 53.1 57.8 58.2 52.7 55.2 51.6 37.1 29.8 29.1 28.9 40.7 26.0 -90V / 60Hz ZNR1 body C2 body ( X-cap.) LF2 coil PCB under RTH1 C30 body ( Y-cap.) HS near Q1 L3 coil T1 Primary coil T1 secondary coil T1 Core C31 body (Bridging-cap.) T900 top-side coil T900 bottom-side coil T900 core Metal ecclosure 53.7 44.9 48.5 42.0 55.0 45.8 45.2 51.1 58.0 47.1 32.4 28.0 27.9 28.2 35.1 TRF No. IECEN60950_1C normali zed to 50 degree C ambien t 62.6 69.2 81.3 74.8 77.1 81.8 82.2 76.7 79.2 75.6 61.1 53.8 53.1 52.9 64.7 50.0 1:12 90V / 60Hz normali zed to 50 degree C ambien t 79.3 70.5 74.1 67.6 80.6 71.4 70.8 76.7 83.6 72.7 58.0 53.6 53.5 53.8 60.7 Underwriters Laboratories Inc. 33.3 34.5 36.8 37.7 38.3 41.2 41.9 48.4 50.6 45.8 34.3 27.9 27.4 27.1 33.8 25.1 -264V / 60Hz 50.9 37.5 37.5 34.9 48.6 40.3 39.2 49.8 56.3 45.5 32.4 28.2 28.0 28.4 33.2 Verdict normali zed to 50 degree C ambien t 58.2 59.4 61.7 62.6 63.2 66.1 66.8 73.3 75.5 70.7 59.2 52.8 52.3 52.0 58.7 50.0 1:28 264V / 60Hz normali zed to 50 degree C ambien t 76.3 62.9 62.9 60.3 74.0 65.7 64.6 75.2 81.7 70.9 57.8 53.6 53.4 53.8 58.6 - 85 85 130 105 125 105 130 110 110 110 125 110 110 110 70 --- - 85 85 130 105 125 105 130 110 110 110 125 110 110 110 70 Issue Date: 2010-05-19 Page 61 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Ambient air Test time (h:m) Model HRPG-450-48 24.4 -90V / 60Hz ZNR1 body C2 body ( X-cap.) LF2 coil PCB under RTH1 C30 body ( Y-cap.) HS near Q1 L3 coil T1 Primary coil T1 secondary coil T1 Core C31 body (Bridging-cap.) T900 top-side coil T900 bottom-side coil T900 core Metal ecclosure Ambient air Test time (h:m) 38.9 41.9 52.3 53.0 52.7 52.2 53.3 60.8 47.4 44.8 34.7 29.7 29.6 29.9 33.8 26.8 -- temperature T of winding: -- t1 (°C) -- R1 (Ω) -- 50.0 1:05 90V / 60Hz normali zed to 50 degree C ambien t 62.1 65.1 75.5 76.2 75.9 75.4 76.5 84.0 70.6 68.0 57.9 52.9 52.8 53.1 57.0 50.0 1:12 24.6 -264V / 60Hz 34.7 35.6 39.9 36.6 39.7 39.3 40.6 57.4 45.4 42.3 32.5 27.9 27.8 28.1 30.5 25.9 -- t2 (°C) R2 ( Ω) -- -- Verdict 50.0 2:18 264V / 60Hz normali zed to 50 degree C ambien t 58.8 59.7 64.0 60.7 63.8 63.4 64.7 81.5 69.5 66.4 56.6 52.0 51.9 52.2 54.6 50.0 1:08 T (°C) -- -- --- - 85 85 130 105 125 105 130 110 110 110 125 110 110 110 70 --- allowed insulation class Tmax (°C) -- -- supplementary information: The temperatures were measured under worst-case normal mode defined in 1.2.2.1 and as described in 1.4.1 at voltages as described in 1.4.5 As per 1.4.12.3 for Non-temperature dependent equipment, T shall not exceed (Tmax + Tamb - Tma) Tma = 45 degree C (the maximum ambient temperature permitted by the manufacturer's specification) Tmax (Transformers, T1, T900), class B = 110 degree C Tmax (LF1, LF2, L3, T2) = 130 degree C Tmax (L100) = 105 degree C Tmax (PWB) = 105 degree C Tmax (Y-Capacitors, C3, C30) = 125 degree C Tmax (X-Capacitors, C1, C2) = 85 degree C Tmax (Electrolytic Capacitor, C5) = 85 degree C Tmax (Bridge Capacitor, C31) = 125 degree C User accessible area: TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 62 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict Tmax (metal enclosure) = 70 degree C 4.5.5 TABLE: Ball pressure test of thermoplastic parts Pass allowed allowed impression diameter (mm)......... : 2.0 — part test temperature (°C) Terminal Block TB1, Switchlab , T35 series 125 impression diameter (mm) 1.1 supplementary information: -- 4.7 TABLE: resistance to fire part -- Pass manufacturer of material -- type of material -- thickness (mm) flammability class -- -- Evidence -- supplementary information: See Critical Component List 5.2 TABLE: electric strength tests, impulse tests and voltage surge tests Test voltage applied between: Voltage shape (AC, DC, impulse, surge) One layer of insulation, thickness 0.05mm * T1 primary to secondary T1 primary to core T1 secondary to core T900 primary to secondary T900 primary to core T900 secondary to core Primary to SELV Primary to Earth Insulation Sheet (Type Formex GK from Formex; Type FR700 from Sabic) AC AC AC AC AC AC AC DC DC AC supplementary information: * Tape tested: 3M Co.: 1350F-1, 1350T-1 Symbio Inc.: 35660, 35660Y Bondtec Pacific Co., Ltd.: 370S TRF No. IECEN60950_1C Underwriters Laboratories Inc. Pass Test voltage (V) 3000 3000 1707 1707 3000 1707 1707 4242 3000 1500 Breakdown Yes / No No No No No No No No No No No Issue Date: 2010-05-19 Page 63 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause 5.3 Component No. Requirement + Test Result - Remark Verdict TABLE: fault condition tests Pass ambient temperature (°C) .................................. : -- — Power source for EUT: Manufacturer, model/type, -output rating..................................................... : — Fault Supply voltage (V) Test time Fuse # Fuse current (A) Observation Model -HRPG-4505 Fan Stalled -- -- -- -- -- 240 1:42 FS1 8 Ventilation openings Blocked 240 1:32 FS1 8 +5V Transformer (T1) overload Before J111 240 9;10 FS1 8 +5V Transformer (T1) overload after D150 240 4:53 FS1 8 +5V Transformer (T1) overload after D151 240 4:58 FS1 8 Unit Cycle protection, NT, NC, NB T1 coil:112 degree C T900 coil:69 degree C, U4 body:73 degree C, Amb:26.4 degree C , I/P: 0.13~2.21A Unit Cycle protection, NT, NC, NB T1 coil:107 degree C, T900 coil:70 degree C, U4 body:74 degree C, Amb:25.3 degree C , I/P: 0.13~2.21A CT at 25 A, (output load 90 A, total load : 115 A), increased to 30 A, Unit shutdown, NT, NB, NC, I/P: (3.05 A), T1 coil:138 degree C, T900 coil: 65 degree C, U4 body:71 degree C, Amb:25.8 degree C CT at 1 A, increased to 2 A, Unit shutdown, NT, NB, NC, I/P: (2.43 A), T1 coil:127 degree C, T900 coil: 69 degree C, U4 body:75 degree C, Amb:25.1 degree C CT at 1.5A, increased to 2.5 A, Unit shutdown, NT, NB, NC, I/P: (2.39 A), T1 coil:94 degree C, T900 coil: 54 degree C, U4 body:55 degree C, Amb:23.5 degree C TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 64 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark +5V Transformer overload after D950 240 2:24 FS1 8 +5V - RTN Short 240Vac 30 min FS1 8 +5V Overload 240Vac 7:14 FS1 8 Model -HRPG-45012 Fan Stalled -- -- -- -- 240 2:06 FS1 8 Ventilation openings Blocked 240 2:40 FS1 8 +12V Transformer (T1) overload Before J111 240 10:21 FS1 8 +12V Transformer (T1) overload after D150 240 11:00 FS1 8 TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict CT at 0.5A, increased to 1 A, Unit shutdown, NT, NB, NC, I/P: (2.35 A), T1 coil:82 degree C, T900 coil: 48 degree C, U4 body:48 degree C, Amb:24.0 degree C Unit shutdown, NT, NC, NB, I/P:0.25A, CT at 105 A, increased to 110 A, Unit shutdown, NT, NB, NC, I/P: ( 2.76 A), T1 coil:107 degree C, T900 coil: 40 degree C, U4 body:61 degree C, Amb:26.1 degree C -- Unit Cycle protection, NT, NC, NB T1 coil:102 degree C, T900 coil:71 degree C, U4 body:74 degree C, Amb:27.3 degree C , I/P: 0.13~2.21A Unit Cycle protection, NT, NC, NB T1 coil:99 degree C, T900 coil:75 degree C, U4 body:80 degree C, Amb:25.6 degree C , I/P: 0.13~2.21A CT at 12A, (output load 37.5A) total load :49.5A) increased to 14A Unit shutdown, NT, NB, NC, I/P: (2.88A) T1 coil:78 degree C T900 coil: 41 degree C U4 body:43 degree C, Amb:28.2 degree C CT at 4 A, increased to 5 A, Unit shutdown, NT, NB, NC, I/P: (2.37 A), T1 coil:84 degree C, T900 coil: 41 degree C, Issue Date: 2010-05-19 Page 65 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark +12V Transformer (T1) overload after D151 240 8:14 FS1 8 +12V RTN +12V Short 240Vac 30 min FS1 8 Overload 240Vac 5:14 FS1 8 Model -HRPG-45012 (+24V / 18.8A) T1 pin 6 - 8 Short -- -- -- -- 240 1 sec FS1 8 T1 pin 9 10 Short 240 1 sec FS1 8 T1 pin FL1 - FL2 Short 240 1 sec FS1 8 Model -HRPG-45012 (+12V / 37.5A) T1 pin 6 - 8 Short -- -- -- -- 240 1 sec FS1 8 T1 pin 9 10 Short 240 1 sec FS1 8 T1 pin FL1 - FL2 Short 240 1 sec FS1 8 -- -- -- -- 240 1 sec FS1 8 Model -HRPG-45012 (+5V / 90A) T1 pin 6 - 8 Short TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict U4 body:46 degree C , Amb:23.7 degree C CT at 2 A, increased to 2.5 A, Unit shutdown, NT, NB, NC, I/P: (2.34 A), T1 coil:70 degree C, T900 coil: 42 degree C, U4 body:53 degree C, Amb:24.7 degree C Unit shutdown, NT, NC, NB, I/P:0.25A, CT at 43 A, increased to 45 A, Unit shutdown, NT, NB, NC, I/P: (2.50 A), T1 coil: 60 degree C, T900 coil:30 degree C, U4 body:39 degree C, Amb:25.1 degree C -- IP(FS1) *, CD(Q3,Q4), NT, NB, NC, I/P:0A CD(T1), NT, NB, NC, I/P:0.14A , Repeat 2 times, result were same IP(FS1) *, CD(Q1,Q2,Q3,Q4), NT, NB, NC, I/P:0A -- IP(FS1) *, CD(Q3,Q4), NT, NB, NC, I/P:0A CD(T1), NT, NB, NC, I/P:0.14A ,Repeat 2 times ,result were same IP(FS1) *, CD(Q1,Q2,Q3,Q4), NT, NB, NC, I/P:0A -- IP(FS1) *, CD(Q3,Q4), NT, NB, NC, I/P:0A Issue Date: 2010-05-19 Page 66 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark T1 pin 9 10 Short 240 1 sec FS1 8 T1 pin FL1 - FL2 Short 240 1 sec FS1 8 Model -HRPG-45024 Fan Stalled -- -- -- -- 240 2:16 FS1 8 Ventilation openings Blocked 240 2:07 FS1 8 +24V Transformer (T1) overload Before J111 240 5;02 FS1 8 +24V Transformer (T1) overload after D150 240 5:35 FS1 8 +24V Transformer (T1) overload after D151 240 7:02 FS1 8 +24V RTN +24V Short 240Vac 30 min FS1 8 Overload 240Vac 4:29 FS1 8 TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict CD(T1), NT, NB ,NC, I/P:0.14A , Repeat 2 times, result were same IP(FS1) *, CD(Q1,Q2,Q3,Q4), NT, NB, NC, I/P:0A -- Unit Cycle protection, NT, NC, NB T1 coil:104 degree C, T900 coil:69 degree C, U4 body:71 degree C, Amb:27.1 degree C , I/P: 0.13~2.21A , Unit Cycle protection, NT, NC, NB T1 coil:104 degree C, T900 coil:72 degree C, U4 body:74 degree C, Amb:27.1 degree C , I/P: 0.13~2.21A , CT at 8 A, (output load 18.8 A, total load :26.8A), increased to 10 A, Unit shutdown, NT, NB, NC, I/P: (3.11 A), T1 coil:96 degree C, T900 coil: 42 degree C, U4 body:44 degree C, Amb:26.0 degree C CT at 1 A, increased to 2 A, Unit shutdown, NT, NB, NC, I/P: (2.25 A), T1 coil:120 degree C, T900 coil: 70 degree C, U4 body:80 degree C, Amb:24.1 degree C CT at 2 A, increased to 2.5 A, Unit shutdown, NT, NB, NC, I/P: (2.26 A), T1 coil:85 degree C, T900 coil: 42 degree C, U4 body:48 degree C, Amb:25.3 degree C Unit shutdown, NT, NC, NB, I/P:0.25A, CT at 22A, increased to 24 Issue Date: 2010-05-19 Page 67 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Model -HRPG-45048 Fan Stalled -- -- -- -- 240 3:08 FS1 8 Ventilation openings Blocked 240 2:47 FS1 8 +48V Transformer (T1) overload Before J111 240 11:37 FS1 8 +48V Transformer (T1) overload after D150 240 5:31 FS1 8 +48V Transformer (T1) overload after D151 240 6:38 FS1 8 +48V RTN Short 240Vac 30 min FS1 8 TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict A, Unit shutdown, NT, NB, NC, I/P: ( 2.56 A), T1 coil:55 ?, T900 coil: 34 degree C, U4 body:42 degree C, Amb:28.9 degree C -- Unit Cycle protection, NT, NC, NB T1 coil:119?, T900 coil:72 degree C, U4 body:80 degree C, Amb:27.1 degree C , I/P: 0.13~2.21A , Unit Cycle protection, NT, NC, NB T1 coil:112 degree C, T900 coil:75 degree C, U4 body:81 degree C, Amb:27.3 degree C , I/P: 0.13~2.21A , CT at 5 A, (output load 9.5 A, total load :14.5A), increased to 6 A, Unit shutdown, NT, NB, NC, I/P: (3.3 A), T1 coil:118 degree C, T900 coil: 41 degree C, U4 body:44 degree C, Amb:25.1 degree C CT at 1 A, increased to 2 A, Unit shutdown, NT, NB, NC, I/P: (2.29 A), T1 coil:120 degree C T900 coil: 67 degree C, U4 body:76 degree C, Amb:24.4 degree C CT at 2 A, increased to 2.5 A, Unit shutdown, NT, NB, NC, I/P: (2.27 A), T1 coil:78 degree C, T900 coil: 38 degree C, U4 body:44 degree C, Amb:25.5 degree C Unit shutdown, NT, NC, NB, I/P:0.25A, Issue Date: 2010-05-19 Page 68 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause +48V Requirement + Test Overload Result - Remark 240Vac 8:18 FS1 8 Model -HRPG-45048 (+48V / 9.5A) U2 SecShort -- -- -- -- 240 30 min FS1 8 U2 Pri- Short 240 30 min FS1 8 U2 Pin 1 Open 240 30 min FS1 8 U3 Sec- Short 240 2h:57m FS1 8 U3 Pri- Short 240 30 min FS1 8 U3 Pin 1 Open 240 2h:54m FS1 8 U4 Sec- Short 240 2h:46m FS1 8 U4 Pri- Short 240 30 min FS1 8 U4 Pin 1 Open 240 2h:28m FS1 8 T1 pin 6 - 8 Short 240 1 sec FS1 8 T1 pin 9 - 240 1 sec FS1 8 Short TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict CT at 12.5A, increased to 13.5 A, Unit shutdown, NT, NB, NC, I/P: ( 2.6A), T1 coil:72 degree C, T900 coil: 45 degree C, U4 body:50 degree C, Amb:24.4 degree C -- Unit shutdown, NT, NB, NC, I/P:0.15A, Unit shutdown, NT, NB, NC, I/P:0.15A, Unit shutdown, NT, NB, NC, I/P:0.15A, Unit Normal operation, NT, NC, NB T1= 57.5 degree C, T900= 27.9 degree C, U4= 46.2 degree C, Amb=25.1 degree C, I/P:2.17 A Unit shutdown, NT, NB, NC, I/P:0.15A, Unit Normal operation, NT, NC, NB T1= 59.8 degree C, T900= 29.8 degree C, U4= 48.0 degree C, Amb=26.9 degree C, I/P:2.17 A Unit Normal operation, NT, NC, NB T1= 57.1 degree C, T900= 27.5 degree C, U4= 46.0 degree C, Amb= 24.8 degree C, I/P: :2.17A Unit shutdown, NT, NB, NC, I/P:0.15A, Unit Normal operation, NT, NC, NB T1= 55.1 degree C, T900=25.2 degree C, U4= 43.5 degree C, Amb=23.3 degree C, I/P:2.17A IP(FS1) *, CD(Q3,Q4), NT, NB,NC, I/P:0A CD(T1), NT, NB, NC, Issue Date: 2010-05-19 Page 69 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark 10 T1 pin FL1 - FL2 T900 pin 1 -2 T900 pin FL1A - 4 T900 pin 5,6 -7,8 Short 240 30 min FS1 8 Short 240 30 min FS1 8 Short 240 30 min FS1 8 Short 240 1h:53m FS1 8 Q1 (G-S) Short 240 2h:9m FS1 8 Q1 (G-D) Short 240 1 sec FS1 8 Q1 (D-S) Short 240 1 sec FS1 8 Q2 (G-S) Short 240 3h:0m FS1 8 Q2 (G-D) Short 240 1 sec FS1 8 Q2 (D-S) Short 240 1 sec FS1 8 Q3 (G-S) Short 240 30 min FS1 8 Q3 (G-D) Short 240 30 min FS1 8 Q3 (D-S) Short 240 1 sec FS1 8 Q4 (G-S) Short 240 30 min FS1 8 Q4 (G-D) Short 240 30 min FS1 8 Q4 (D-S) Short 240 1 sec FS1 8 BD1 (L-+) Short 240 1 sec FS1 8 C5 Short 240 1 sec FS1 8 TRF No. IECEN60950_1C Underwriters Laboratories Inc. Verdict I/P:0.14A , Repeat 2 times, result were same Unit shutdown, NT, NB, NC, I/P:0.15A, Unit shutdown, NT, NB, NC, I/P:0.15A, Unit shutdown, NT, NB, NC, I/P:0.15A, Unit Normal operation, NT, NC, NB T1=55.2 degree C, T900= 25.4 degree C, U4= 43.7 degree C, Amb= 23.3 degree C, I/P:2.17A Unit Normal operation, NT, NC, NB T1= 56.3 degree C, T900=26.2 degree C, U4= 44.6 degree C, Amb= 24.6 degree C, I/P:2.17A IP(FS1) *, CD(Q1,Q2), NT, NB, NC, I/P:0A IP(FS1) *,CD(Q1,Q2), NT, NB, NC, I/P:0A Unit Normal operation, NT, NC, NB T1=57.3 degree C, T900= 27.7 degree C, U4= 46.0 degree C, Amb=26.1 degree C, I/P: 2.17A IP(FS1) *, CD(Q1,Q2), NT, NB, NC, I/P:0A IP(FS1) *, CD(Q1, Q2), NT, NB, NC, I/P:0A Unit shutdown, NT , NB, NC, I/P:0.15A, Unit shutdown, NT , NB, NC, I/P:0.15A, IP(FS1) *,CD(Q3), NT, NB, NC, I/P:0A Unit shutdown, NT, NB, NC, I/P:0.15A, Unit shutdown, NT, NB, NC, I/P:0.15A, IP(FS1) *, CD(Q4), NT, NB, NC, I/P:0A IP(FS1) *, CD(Q1,Q2), NT, NB, NC, I/P:0A IP(FS1) *, CD(Q1,Q2), NT, Issue Date: 2010-05-19 Page 70 of 70 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 Clause Requirement + Test Result - Remark Verdict NB, NC, I/P:0A supplementary information: Results Key: IP = Internal protection operated (component indicated) CT = Constant temperatures were obtained TW = Transformer winding opened CD = Components damaged (damaged components indicated) NB = No indication of dielectric breakdown YB = Dielectric breakdown (time and location indicated) NC = Cheesecloth remained intact YC = Cheesecloth charred or flamed NT = Tissue paper remained intact YT = Tissue paper charred or flamed * : Test repeated with the following fuses, results were the same: Type UBM from Conquer Electronics; Type 216 from Littelfuse; Type 5HF from Bel Fuse; Type FSC from Walter Electronic TRF No. IECEN60950_1C Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 1 of 10 Report Reference # Enclosure National Differences USA / Canada Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 2 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict USA / Canada - Differences to IEC 60950-1:2005, Second Edition 1.1 Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C2. Pass 1.1.1 Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions. Pass 1.1.2 Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded. N/A 1.1.2 Special requirements apply to equipment intended for use outdoors. N/A 1.4.14 For Pluggable Equipment Type A, the protection in To be evaluated in end the installation is assumed to be 20 A. product. N/A 1.5.1 All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P.1. Pass 1.5.1 All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P.2. Pass 1.5.5 Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like. N/A 1.5.5 For other than limited power and TNV circuits, the type of output circuit identified for output connector. N/A 1.5.5 External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC. N/A 1.5.5 Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable. N/A 1.5.5 Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope. N/A 1.5.5 Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No. 233. N/A 1.6.1.2 Equipment intended for connection to a d.c. power (mains) distribution system is subject to special N/A Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 3 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict circuit classification requirements (e.g., TNV -2) 1.6.1.2 Earthing of d.c. powered equipment provided. N/A 1.7 Lamp replacement information indicated on lampholder in operator access area. N/A 1.7.1 Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor. N/A 1.7.1 Equipment voltage rating not higher than rating of the plug except under special conditions. 1.7.6 Special fuse replacement marking for operator accessible fuses. 1.7.7 Identification of terminal connection of the equipment earthing conductor. 1.7.7 Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used. 1.7.7 Marking located adjacent to terminals and visible during wiring. 2.1.1.1 Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover. N/A 2.3.1.b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M.4. N/A 2.3.1.b For TNV -2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 mA peak or 30 mA d.c. under normal conditions. N/A 2.3.1.b Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M.3.1.4. N/A 2.3.2.1 In the event of a single fault, the limits of 2.2.3 apply to SELV circuits and accessible conductive parts. N/A 2.3.2.4 Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and N/A Not used. N/A N/A To be evaluated in end product. N/A N/A To be evaluated in end product. Underwriters Laboratories Inc. N/A Issue Date: 2010-05-19 Page 4 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict routine testing. 2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable. N/A 2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth. N/A 2.6.3.3 For Pluggable Equipment Type A, if a) b) or c) are not applicable, the current rating of the circuit is taken as 20 A N/A 2.6.3.4 Capacity of connection between earthing terminal To be evaluated in end and parts required to be earthed subject to special product. conditions based on the current rating of the circuit. N/A 2.6.3.4 Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No.0.4. N/A 2.6.4.1 Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada. N/A 2.7.1 Data for selection of special external branch circuit overcurrent devices marked on the equipment. N/A 2.7.1 Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part 1. N/A 2.7.1 Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring. N/A 2.7.1 Additional requirements for overcurrent protection apply to equipment provided with panelboards. N/A 2.7.1 Non-motor-operated equipment requiring special overcurrent protective device marked with device rating. N/A 2.10.5.12 Multi-layer winding wire subject to UL component wire requirements in addition to 2.10.5.12 and Annex U. N/A 3.1.1 Permissible combinations of internal wiring/external PWB traces are not evaluated to limited short-circuit test of CSA C22.2 No. 0.4. Proper bonding to the end-product main protective earthing termination is required. Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 5 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict cable sizes for overcurrent and short circuit protection. 3.1.1 All interconnecting cables protected against overcurrent and short circuit. N/A 3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC, Part 1. 3.2.1 Permitted use for flexible cords and plugs. N/A 3.2.1 Flexible cords provided with attachment plug rated 125% of equipment current rating. N/A 3.2.1 Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug. N/A 3.2.1.2 Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord). N/A 3.2.1.2 Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing N/A 3.2.1.2 Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection. N/A 3.2.1.2 Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment. N/A 3.2.1.2 Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment. N/A 3.2.1.2 Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard. N/A 3.2.3 Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Pass To be evaluated in end product. Underwriters Laboratories Inc. N/A Issue Date: 2010-05-19 Page 6 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict Part 1. 3.2.3 Permanently connected equipment may have terminals or leads not smaller than No. 18 AWG (0.82 mm²) and not less than 150 mm in length for connection of field installed wiring. N/A 3.2.3 If supply wires exceed 60 °C, marking indicates use of 75 °C or 90 °C wiring for supply connection as appropriate. N/A 3.2.3 Equipment compatible with suitable trade sizes of conduits and cables. N/A 3.2.5 Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation. N/A 3.2.5 Conductors in power supply cords sized according to NEC and CEC, Part I. N/A 3.2.5 Power supply cords and cord sets incorporate flexible cords suitable for the particular application. N/A 3.2.6 Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source. N/A 3.2.9 Adequate wire bending space and volume of field wiring compartment required to properly make the field connections. N/A 3.2.9 Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse. N/A 3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with 3.3. N/A 3.3 Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated. N/A 3.3.1 Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means. 3.3.3 Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm²) or smaller conductor if provided with upturned lugs, cupped To be evaluated in end product. Underwriters Laboratories Inc. N/A Pass Issue Date: 2010-05-19 Page 7 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict washer or equivalent retention. 3.3.4 Terminals accept wire sizes (gauge) used in the U.S. and Canada. To be evaluated in end product. 3.3.4 Terminals accept current-carrying conductors rated 125% of the equipment current rating. 3.3.6 Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used. N/A 3.3.6 Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor. N/A 3.3.6 Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads. N/A 3.4.2 Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V. N/A 3.4.8 Vertically mounted disconnect devices oriented so up position of handle is "on". N/A 3.4.11 For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means. N/A 4.2.8.1 Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more. N/A 4.2.9 Compartment housing high-pressure lamp marked to indicate risk of explosion. N/A 4.2.11 For equipment intended for mounting on racks and provided with slide/rails allowing the equipment to slide away from the rack for installation, service and maintenance, additional construction, performance and marking requirements are applicable to determine the adequacy of the slide/rails. N/A 4.3.2 Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit. N/A 4.3.6 In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements. N/A 4.3.12 The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6). N/A Underwriters Laboratories Inc. Pass Pass Issue Date: 2010-05-19 Page 8 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict 4.3.12 Equipment using replenishable liquids marked to indicate type of liquid to be used. N/A 4.3.13.2 Equipment that produces x-radiation and does not comply with 4.3.12 under all conditions of servicing marked to indicate the presence of radiation where readily visible. N/A 4.3.13.5 Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040 and REDR C1370). N/A 4.7 Automated information storage equipment intended to contain more than 0.76 m³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system. N/A 4.7.3.1 Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL 2043. Equipment for installation in space used for environmental air as described in Sec. 300-22(c) of the NEC provided with instructions indicating suitability for installation in such locations. N/A 4.7.3.1 Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m² or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications. N/A 4.7.3.4 Wire marked "VW-1" or "FT-1" considered equivalent. 5.1.8.2 Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections. N/A 5.1.8.3 Touch current due to ringing voltage for equipment containing telecommunication network leads. N/A 5.3.7 Overloading of SELV connectors and printed wiring board receptacles accessible to the operator. Pass 5.3.7 Tests interrupted by opening of a component repeated two additional times. Pass 5.3.9.1 Test interrupted by opening of wire or trace subject to certain conditions. N/A 6 Specialized instructions provided for telephones that may be connected to a telecommunications N/A Underwriters Laboratories Inc. Pass Issue Date: 2010-05-19 Page 9 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict network. 6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network. N/A 6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection. N/A 6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable. N/A 6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C). N/A 6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions. N/A 7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC. N/A H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370. N/A M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations. N/A M.4 Special requirements for message waiting and similar telecommunications signals. N/A NAC Equipment intended for use with a generic secondary protector marked with suitable instructions. N/A NAC Equipment intended for use with a specific primary or secondary protector marked with suitable instructions. N/A NAD Acoustic pressure from an ear piece less than 136 dBA for short duration disturbances, and less than 125 dBA for handsets, 118 dBA for headsets, and 121 dBA for insert earphones, for long duration disturbances. N/A NAD Equipment connected to a telecommunication and N/A Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 10 of 10 Report Reference # E183223-A123-UL-1 IEC 60950-1:2005 SubClause Difference + Test Result - Remark Verdict cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. NAF Household/Home Office Document Shredders N/A NAF.1.7 Markings and instructions alert the user to key safety considerations related to use of shredders, including not intended to be used by children, avoid touching document feed opening, avoid clothes and hair entanglement, and avoid aerosol products. N/A NAF.2.8.3 Safety interlock cannot be inadvertently activated by the articulated accessibility probe (figure NAF.1). N/A NAF.3.4 Provided with an isolating switch complying with 3.4.2, including 3 mm contact gap, with appropriate markings associated with the switch. N/A NAF.4.4 Hazardous moving parts are not accessible, as determined using the articulated accessibility probe (figure NAF.1) and the accessibility probe/wedge (figures NAF.2/NAF.3). N/A Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 1 of 11 Report Reference # Enclosure Photographs Supplement Id Description 3-01 External View 1 3-02 External View 2 3-03 Internal View with Chassis 1 3-04 Internal View with Chassis 2 3-05 Main PWB Components 3-06 Main PWB Traces 3-07 Constrol PWB Components 3-11 Control PWB Traces 3-12 Small Secondary PWB Top 3-13 Small Secondary PWB Bottom Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 2 of 11 Report Reference # Photographs ID 3-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 3 of 11 Report Reference # Photographs ID 3-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 4 of 11 Report Reference # Photographs ID 3-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 5 of 11 Report Reference # Photographs ID 3-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 6 of 11 Report Reference # Photographs ID 3-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 7 of 11 Report Reference # Photographs ID 3-06 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 8 of 11 Report Reference # Photographs ID 3-07 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 9 of 11 Report Reference # Photographs ID 3-11 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 10 of 11 Report Reference # Photographs ID 3-12 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 11 of 11 Report Reference # Photographs ID 3-13 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 1 of 11 Report Reference # E183223-A123-UL-1 Enclosure Diagrams Supplement Id Description 4-01 Enclosure drawings 4-02 Heatsink drawing (HS1) 4-03 Heatsink drawing (HS2) 4-04 Heatsink drawing (HS3) 4-05 Heatsink drawing (HS4) 4-10 Heatsink drawing (for Thermal Switch) 4-11 Insulation Sheet on Top Chassis near L100 4-12 Insulation Sheet on Top Chassis above C5 and L3 4-13 Insulation Sheet between PWBs Traces and Bottom Chassis Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 2 of 11 Report Reference # Diagrams ID 4-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 3 of 11 Report Reference # Diagrams ID 4-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 4 of 11 Report Reference # Diagrams ID 4-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 5 of 11 Report Reference # Diagrams ID 4-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 6 of 11 Report Reference # Diagrams ID 4-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 7 of 11 Report Reference # Diagrams ID 4-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 8 of 11 Report Reference # Diagrams ID 4-10 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 9 of 11 Report Reference # Diagrams ID 4-11 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 10 of 11 Report Reference # Diagrams ID 4-12 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 11 of 11 Report Reference # Diagrams ID 4-13 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 1 of 19 Report Reference # Enclosure Schematics + PWB Supplement Id Description 5-01 Schematics and Component Differences 5-02 PWBs layouts Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 2 of 19 Report Reference # Schematics ID 5-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 3 of 19 Report Reference # Schematics ID 5-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 4 of 19 Report Reference # Schematics ID 5-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 5 of 19 Report Reference # Schematics ID 5-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 6 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 7 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 8 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 9 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 10 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 11 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 12 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 13 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 14 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 15 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 16 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 17 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 18 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 19 of 19 Report Reference # Schematics ID 5-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 1 of 107 Report Reference # Enclosure Miscellaneous Supplement Id Description 7-01 Spec for transformer T1 from Jet Signal 7-02 Spec for transformer T1 from Elytone 7-03 Spec for transformer T1 from Long Sail 7-04 Spec for transformer T900 from Jet Signal 7-05 Spec for transformer T900 from Elytone 7-06 Spec for transformer T900 from Long Sail 7-07 Spec for Inductors LF1 LF2 7-08 Spec for Inductor L3 7-09 Spec for Inductor T2 TR -435 7-10 Spec for Inductor T2 TR -852 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 2 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 3 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 4 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 5 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 6 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 7 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 8 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 9 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 10 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 11 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 12 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 13 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 14 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 15 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 16 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 17 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 18 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 19 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 20 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 21 of 107 Report Reference # Misc ID 7-01 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 22 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 23 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 24 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 25 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 26 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 27 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 28 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 29 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 30 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 31 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 32 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 33 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 34 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 35 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 36 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 37 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 38 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 39 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 40 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 41 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 42 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 43 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 44 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 45 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 46 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 47 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 48 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 49 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 50 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 51 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 52 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 53 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 54 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 55 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 56 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 57 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 58 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 59 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 60 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 61 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 62 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 63 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 64 of 107 Report Reference # Misc ID 7-02 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 65 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 66 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 67 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 68 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 69 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 70 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 71 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 72 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 73 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 74 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 75 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 76 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 77 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 78 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 79 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 80 of 107 Report Reference # Misc ID 7-03 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 81 of 107 Report Reference # Misc ID 7-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 82 of 107 Report Reference # Misc ID 7-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 83 of 107 Report Reference # Misc ID 7-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 84 of 107 Report Reference # Misc ID 7-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 85 of 107 Report Reference # Misc ID 7-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 86 of 107 Report Reference # Misc ID 7-04 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 87 of 107 Report Reference # Misc ID 7-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 88 of 107 Report Reference # Misc ID 7-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 89 of 107 Report Reference # Misc ID 7-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 90 of 107 Report Reference # Misc ID 7-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 91 of 107 Report Reference # Misc ID 7-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 92 of 107 Report Reference # Misc ID 7-05 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 93 of 107 Report Reference # Misc ID 7-06 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 94 of 107 Report Reference # Misc ID 7-06 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 95 of 107 Report Reference # Misc ID 7-06 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 96 of 107 Report Reference # Misc ID 7-06 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 97 of 107 Report Reference # Misc ID 7-06 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 98 of 107 Report Reference # Misc ID 7-07 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 99 of 107 Report Reference # Misc ID 7-07 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 100 of 107 Report Reference # Misc ID 7-08 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 101 of 107 Report Reference # Misc ID 7-08 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 102 of 107 Report Reference # Misc ID 7-09 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 103 of 107 Report Reference # Misc ID 7-09 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 104 of 107 Report Reference # Misc ID 7-09 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 105 of 107 Report Reference # Misc ID 7-10 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 106 of 107 Report Reference # Misc ID 7-10 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 107 of 107 Report Reference # Misc ID 7-10 Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 1 of 4 Report Reference # Enclosure Test Record Description Test Record 1 CRD Datasheet Underwriters Laboratories Inc. E183223-A123-UL-1 Issue Date: 2010-05-19 Page 2 of 4 Report Reference # E183223-A123-UL-1 Test Record No. 1 --The manufacturer submitted representative production samples of Switching Power Supplies, Models HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48). --The results of this investigation, including construction review and testing, indicate that the products evaluated comply with the applicable requirements in the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment CAN/CSA-C22.2 No. 60950-1-07 and UL60950-1 Second Edition, date March 27, 2007. --All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under the TPTDP program. --Test results reported relate only to the items tested. --The following tests conducted in accordance with UL60950-1, 2nd Edition, Revised Date March 27, 2007, Information Technology Equipment-Safety-Part 1: General Requirements were considered representative of the same tests required by Canadian Standards, CAN/CSA-C22.2 No.60950-1-07, 2nd Edition, Date March, 2007, Information Technology Equipment-Safety-Part 1: General Requirements. Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 3 of 4 Report Reference # E183223-A123-UL-1 The following tests were conducted: Test Testing Location/Comments End Product Reference Page General Guidelines Power Supply Reference Page Maximum Output Voltage, Current, and Volt-Ampere Measurement (1.2.2.1) Input: Single-Phase (1.6.2) Durability of Marking (1.7.11) Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10) Capacitance Discharge (2.1.1.7) SELV Reliability (2.2.2, 2.2.3, 2.2.4, Part 22 6.1) Limited Current Circuit Measurement (2.4.1, 2.4.2) Protective Bonding I (2.6.3.4, 2.6.1).7) Protective Bonding II (2.6.3.4, 2.6.1) Humidity (2.9.1, 2.9.2, 5.2.2) Determination of Working Voltage; Working Voltage Measurement (2.10.2) Determination of Working Voltage; Hazardous Voltage (Circuit) Measurement (2.10.2, Part 22 6.1) Transformer and Wire /Insulation Electric Strength (2.10.5.6, 2.10.5.13) Thin Sheet Material (2.10.5.9, 2.10.5.10, 2.10.5.6) Heating (4.5.1, 1.4.12, 1.4.13) Ball Pressure (4.5.5, 4.5) Touch Current (Single-Phase; TN/TT System) (5.1, Annex D) Electric Strength (5.2.2) Component Failure (5.3.1, 5.3.4, 5.3.7) Abnormal Operation (5.3.1 - 5.3.9) Transformer Abnormal Operation (5.3.3, 5.3.7b, Annex C.1) Power Supply Output Short-Circuit/Overload (5.3.7) Test results are valid only for the tested equipment. These tests are considered representative of the products covered by this Test Report. The test methods and results of the above tests have been reviewed and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this Test Report. Underwriters Laboratories Inc. Issue Date: 2010-05-19 Page 4 of 4 Report Reference # Underwriters Laboratories Inc. E183223-A123-UL-1