Report - Mean Well Web

advertisement
MS. SANDY HSU
MEAN WELL ENTERPRISES CO LTD
28 WU-CHUAN 3RD RD
WUGU INDUSTRIAL PARK
TAIPEI HSIEN
248 TAIWAN
Date:
Subscriber:
PartySite:
File No:
Project No:
PD No:
Type:
PO Number:
05/19/2010
710861002
156523
E183223
10CA22607
10O20017
R
98-0891
Subject: UL Certification Documents For Applicant
This authorization is effective from the date of this Notice and only for products
produced at the manufacturing location(s) specified on the current Authorization
Page. Records in the Follow-Up Services Procedure covering the product are
identified on the Addendum and attached.
Products that bear the UL Mark shall be identical to those that were evaluated by UL
and found to comply with UL’s requirements. If changes in construction are
discovered, appropriate action will be taken for products not in compliance and
continued use of the UL Mark may be withdrawn. UL may elect to withdraw use of the
UL Mark if the Applicant or Manufacturer fails to comply with UL's requirements,
including ongoing compliance of the product under UL's Follow-Up Services.
The contents of this Letter are intended solely for the use of UL, the Applicant and
specified Manufacturers.
The opinions and findings of UL represent its judgment
given with due consideration to the limitations of practical operation in accordance
with UL’s objectives and purposes.
UL shall not incur any obligation or liability for any loss, expense or damages,
including incidental, consequential or punitive damages, arising out of or in
connection with the use or reliance upon the contents of this letter to anyone other
than the Applicant as provided in the agreement between UL and Applicant. Any use
or reference to UL’s name or certification mark(s) by anyone other than the
Applicant in accordance with the agreement is prohibited without the express written
approval of UL.
This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any
authorized licensee of UL.
The following material resulting from the investigation under the above numbers is
enclosed.
Document
Index
UL Test Report
05/19/10
Volume
X1
X1
Report Reference Status
E183223-A123-UL-1
Date
New
Please file revised Authorizations, Indices, and General Inspection Instructions in
place of material of like identity. New Test Reports should be filed immediately
following the last Test Report. Amendments or Corrections should be filed
immediately before the Test Report to which they relate. Re-issued Test Reports
should be filed immediately before all material related to the Test Report that it
replaces.
NOTE: Manufacturers receive only the following sub-sections of the Applicant’s
complete Test Report, where applicable: Cover Page, Specific Inspection Criteria (BA
through BE), Specific Technical Criteria (through section CF), Critical Components
table, and Enclosures containing image supplements. Manufacturers do not receive
Test Report information related to standard clause compliance or testing results.
NOTE: Manufacturers that require an Initial Product Inspection (IPI) have received
their copy of the Follow-Up Service Procedure, but are instructed they are not
allowed to ship products bearing the UL Mark until their UL Representative has
successfully conducted the Initial Production Inspection.
Please review this material and report any inaccuracies to UL Canada Customer
Service, PHONE: 1-866-9373ULC (1-866-937-3852), FAX: 1-416-757-8727, E-MAIL:
CustomerService.ca@ca.ul.com, referring to the above Project and/or PD Numbers.
This material is provided on behalf of Underwriters Laboratories Inc.(UL) or any
authorized licensee of UL.
c: TRT File
File
E183223
Volume
Page
Date:
X1
1
18-May-10
Index
Index
Product Type
Model/Type Reference
Report Reference #
Open Frame
Power Supply
Open Frame
Power Supply
Switching Power
Supply
PD-45PR
E183223-A8-UL-1
PPQ-1003X, where X may be A, B, C, or D.
E183223-A10-UL-1
S-40-w where w can be 5, 12, 15, or 24
S-60-x where x can be 5, 9, 12, 15 or 24
D-60y, where y can be A or B
T-60z, where z can be A, B, BTE or C
PTsb-181CL, and PTsb-205CL
E183223-A12-UL-1
Models DRP-240-x (where x can be 24 or 48)
E183223-A14-UL-1
DR-120-x (where x can be 12, 24 or 48)
E183223-A16-UL-1
UR24-6, UR48-3
E183223-A15-UL-1
DP-260OR, DP -130OR
E183223-A18-UL-1
Open Frame
Power Supply
Switching Power
Supply
Switching Power
Supply
Switching Power
Supply
Switching Power
Supply
Switching Power
Supply
E183223-A13-UL-1
Models Rx-y -z, where x can be S, D, ID, T or Q; E183223-A19-UL-1
y can be 85, 100 and z can be 3.3, 5, 12, 15,
24, 48, A, B, C, or D.
Switching Power Models Rx-y -z, where x can be S, D, ID, T or Q; E183223-A22-UL-1
Supply
y can be 65, 75 and z can be 3.3, 5, 12, 15, 24,
48, A, B, C, or D.
DIN RAIL Power DRT-240-24, DRT-240-48.
E183223-A20-UL-1
Supply
Switching Power RS-25-x, where x can be 3.3, 5, 12, 15, 24, 48. E183223-A23-UL-1
Supply
Switching Power Rx-50y, where x can be S, D, T, ID or Q, y can E183223-A26-UL-1
Supply
be -3.3, -5, -12, -15, -24, -48, A, B, C or D.
Switching Power RS-35-x, where x can be 3.3, 5, 12, 15, 16, 24 E183223-A25-UL-1
Supply
or 48. RD-35y where y can be A, B or 13.
Switching Power Rx-yz, where x can be S, D, T, ID or Q; y can be E183223-A24-UL-1
Supply
125 or 150; z can be -3.3, -5, -12, -15, -24, -48,
-1224, -1248, -2448, -2412, -4812, -4824, A, B,
C or D.
RID-125-1205, RID-125-2405, RS-150-7.5, RS150-9
NES-150-x, where x=3.3, 5, 7.5, 9, 12, 15, 24,
48
Switching Power PSP-600-x, where x can be 5, 12, 13.5, 15, 24, E183223-A28-UL-1
Supply
27, 32 or 48.
Switching Power SP-750-x, where x can be 5, 12, 15, 24, 27, 36 E183223-A27-UL-1
Supply
or 48 and SP-750-yAPI-1, where y can be 24 or
48,
File
E183223
Index
Volume
Page
Date:
X1
2
18-May-10
SP-750-yOCE ans SP-750-yOCE where y can
be 24 or 48
Open frame
LPS-50-X, X = 3.3, 5, 7.5, 12, 13.5, 15, 24, 27, E183223-A5-UL-2
power supply
48
Power Supply
DR-480-X, DRP-480-X, DR-480S -X, DRP E183223-A17-UL-3
480S -X (X = 24, 48)
Switching Power PD-85SP
E183223-A31-UL-1
Supply
Redundant Power MP1K0-aaaaaaa, MP1K0-aaaaab, MP1K0E183223-A36-UL-1
Supply
aaaaba, MP1K0-aaabaa, MP1K0-aabaaa,
MP1K0-abaaaa, MP1K0-baaaaa, MP1K0bbaaa-c, MP1K0-abbaa-c, MP1K0-aabba-c,
MP1K0-aaabb-c, MP1K0-babaa, MP1K0-baaba,
MP1K0-baaab, MP1K0-aabab, MP1K0-ababa,
MP1K0-abaab, MP1K0-bbba-c, MP1K0-abbb-c,
MP1K0-babb-c, MP1K0-bbab-c, where a can be
A-X or #; b can be 2A-2K or ##; c can be 1, 2, 3,
4, 5, 6 or blank.
Redundant Power MP650-aaaaa, MP650-aaab, MP650-aaba,
E183223-A32-UL-1
Supply
MP650-abaa, MP650-baaa, MP650-abb-c,
MP650-bba-c, MP650-bab, where a can be A-X
or #; b can be 2A-2K or ##; c can be 1, 2 or
blank.
DIN RAIL Power DRT-960X-Y (X = P or blank; Y = 24 or 48)
E183223-A34-UL-1
Supply
Switching Power DR-60-x, where x can be 5, 12, 15, or 24.
E183223-A37-UL-1
Supply
Switching Power DR-30-x, where x can be 5, 12, 15, or 24.
E183223-A33-UL-1
Supply
Switching Power IPC-300A, IPC-300B, IPC-250, IPC-200
E183223-A41-UL-1
Supply
Switching Power USP-350-x (x = 3.3, 5, 12, 15, 24, 48, 53AD)
E183223-A45-UL-1
Supply
Other
SP-125CL
E183223-A47-UL-1
Switching Power NES-15-x (x = 5, 12, 15, 24, 48)
E183223-A50-UL-1
Supply (For BuiltIn)
Switching Power NES-25-x (x = 5, 12, 15, 24, 48)
E183223-A51-UL-1
Supply (For BuiltIn)
Switching Power NES-100-x (x = 5, 7.5, 9, 12, 15, 24, 48)
E183223-A58-UL-1
Supply (For BuiltIn)
Switching Power RPX-65Y, where X may be D or T, and Y may E183223-A62-UL-1
Supply (Building- be C, D, E, F or G.
in type)
Switching Power QP-320D, QP-320F
E183223-A60-UL-1
Supply, Openframe, Built-In
Switch Model
S-100-F-x (x=5, 7.5, 12, 15, 24, or 48)
E183223-A63-UL-1
Power Supplies
Switching Power SP-480-15AE, SP-480-x, where x can be 3.3, 5, E183223-A9-UL-2
Supply
12, 15, 24, 48, PSP-450-53PD
Switching Power PPS-200-x (x = 5, 12, 15, 24, 27, 48)
E183223-A65-UL-1
File
E183223
Supply, OpenFrame, Built-In
Switching Power
Supply
Switching Power
Supply
Switching Power
Supply
Open Frame
Switching Power
Supply
Switching Power
Supply
Index
Volume
Page
Date:
X1
3
18-May-10
SE-1000-X where X can be 5, 9,12,15, 24 or 48. E183223-A66-UL-1
PT-4503CO
E183223-A70-UL-1
ASP-150-X (X = 12, 15, 20, 24, 27 or 48)
E183223-A72-UL-1
PS-35-X, where X can be 3.3, 5, 7.5, 12, 13.5,
15, 24, or 48.
E183223-A74-UL-1
Switching Power Supply Unit:
E183223-A78-UL-1
RSP-1000-x, where x can be 12, 15, 24, 27 or
48
RCP -1000-xy, where x can be 12, 24 or 48, y=C or Blank
Backplane rack:
RCP -1Uz, where z can be I or T
Battery Charger
Switching Power supply with Rack:
RCP -3K1Uz-xy, x can be 12, 24 or 48, y can be
-C or blank, and z can be I or T. Mounting Rack
PB-xy-z where x (total output power) can be 300 E183223-A80-UL-1
or 360, y can be P (with PFC choke) or N (no
PFC choke) and z (output voltage) can be 12,
24 or 48 or 48ET-1
PID-250X, where X can be A, B, C or D
E183223-A81-UL-1
Open Frame
Switching Power
Supply
DC-DC Converter NSD15-xyz (x can be 12 or 48; y can be S or D;
z can be 3, 5, 12 or 15)
DC-DC converter NSD10-xyz (x can be 12 or 48; y can be S or D;
z can be 3, 5, 9, 12 or 15)
DIN RAIL Power DRH-120-24 and DRH-120-48
Supply
Switching Power RS-15-X where X may be 3.3, 5, 12, 15, 24 or
Supply
48
Switching Power USP-500-X where X denotes output voltage
Supply
which may be 5, 12, 15, 24 or 48.
DIN Rail Power
DR-100-X where X denotes output voltage,
Supply
which may be 12, 15 or 24.
DIN RAIL Power DRT-480-24, DRT-480-48 and DRT-480-36PE
Supply
Open Frame
PPx-125y, where x can be S or T; when x equal
Switching Power to S, that y will be -3.3, -5, -9, -12, -13.5, -15, Supply
24, -27 or -48; when x equal to T that y will be
A, B, C or D.
Open frame
switching power
supply
Single Output
E183223-A83-UL-1
E183223-A82-UL-1
E183223-A84-UL-1
E183223-A85-UL-1
E183223-A86-UL-1
E183223-A87-UL-1
E183223-A21-UL-2
E183223-A7-UL-2
PPT-125AA
RPS-60-12AT
E183223-A90-UL-1
MDR-x-y ( x = 40 or 60, y = 5, 12, 24, 48)
E183223-A91-UL-1
File
E183223
Index
Volume
Page
Date:
X1
4
18-May-10
Industrial DIN
Rail Power
Supply
DC-DC Power
SD-200C-24
E183223-A93-UL-1
Supply
Switching Power P-600-13.8, P-600-27, P-600-48, SE-600-5, SE- E183223-A2-UL-3
Supply
600-12, SE-600-15, SE-600-24, SE-600-27, SE600-36, SE-600-48, CE-S600-24-B
2/8 Stage
PB-1000-x
E183223-A94-UL-1
Switching Mode
Battery Charger Where x (output voltage) can be 12, 24, 48.
Open Frame
Pw-120x-yPzz, where w can be S, A, or B;
E183223-A95-UL-1
Switching Power where x can be P or N; where y can be 13, 27,
Supply
or 54; and where z can be 0-9, A-Z, or blank.
Switching Power PID-24RC
E183223-A98-UL-1
Supply
Switch mode type ID-60B, IT-60D, IT-60F, IQ-60D, IQ-60F
E183223-A1-UL-3
power supply
Switching Power Model: NED-100XY, X=A, B, C, D for output
E183223-A100-UL-1
Supply
rating differences; Y=GD (Secondary Output
Functional Earthing separated without Jump
(J101) or blank (Secondary Output connected
with Functional Earthing together)
Switching Power CLG-150-XY
E183223-A96-UL-2
Supply
(X=12, 15, 20, 24, 30, 36, or 48;
Y=A, B or C)
Building-In
PSC-60A, PSC-60B
E183223-A101-UL-1
Switching Power
Supplies
Building-In
SE-450-X, where X can be 3.3, 5, 12, 15, 24, 36 E183223-A102-UL-1
Switching Power or 48
Supply
Building-In
SE-1500-X, where X can be 5, 12, 15, 24, 27 or E183223-A103-UL-1
Switching Power 48
Supplies
Switching Power HRPX-150-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A106-UL-1
Supply
15, 24, 36, 48).
Building-In
RSP-3000-X, where X can be 12, 24, or 48
E183223-A104-UL-1
Switching Power
Supplies
RSP-2400-X, where X can be 12, 24, or 48
Single Output
DR-15-X (X may be 5, 12, 15, or 24)
E183223-A105-UL-1
Industrial DIN
Rail Power
Supply
Redundant Power MP450-aaaaa, MP450-aaab, MP450-aaba,
E183223-A35-UL-2
Supply
NP450-abaa, MP450-baaa, MP450-abb-c, MP450bba-c, MP450-bab, where a can be A-X or
#; b can be 2A-2K or ##; c can be 1, 2 or blank.
Open Frame
MPT-120BC88
E183223-A108-UL-1
Switching Power
Supply
Switching Power HRPX-600-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A109-UL-1
Supply
15, 24, 36, 48), HRPG-600-48UN
File
E183223
Switching Power
Supply
Building-In
Switching Power
Supplies
Switching Power
Supplies
Switching Power
Supply
Index
Volume
Page
Date:
X1
5
18-May-10
ELN-30-9, ELN-30-9GE
E183223-A110-UL-1
PSC-100A, PSC-100B, PSC-100AHO
E183223-A111-UL-1
HRPX-300-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A112-UL-1
15, 24, 36, 48)
SP-320-3.3, SP-320-5, SP-320-7.5, SP-320-12, E183223-A3-UL-4
SP-320-13.5, SP-320-15, SP-320-24, SP-32027, SP-320-36, SP-320-48, SP-320-7.5EV, SP320-36NP, SPV-300-12, SPV-300-24, SPV-30048, SPV-150-12, SPV-150-24, SPV-150-48
Switching Power RSP-1500-X (X can be 5, 12, 15, 24, 27, 27VS, E183223-A39-UL-2
Supply
48); SPV-1500-X (X can be 12, 24, 48).
Note: X denotes output DC voltage.
Switching Power SP-240-X, X = 5, 7.5, 12, 15, 24, 30, 48
E183223-A114-UL-1
Supplies
Open Frame
LPS-75-3.3, LPS-75-5, LPS-75-12, LPS-75-15, E183223-A4-UL-3
Power Supply
LPS-75-24, LPS-75-48.
LPS-75-24GR
Switching Power HRP -75-X, X = 3.3, 5, 7.5, 12, 15, 24, 36, 48
E183223-A115-UL-1
Supplies
Switching Power HRP -100-X (X = 3.3, 5, 7.5, 12, 15, 24, 36, 48) E183223-A119-UL-1
Supplies
Switching Power HLG-240x-yz (x can be H or blank, y can 12, 15, E183223-A117-UL-1
Supply
20, 24, 30, 36, 42, 48 or 54, z can be A, B, C or
blank)
Switching Power ELP-75-X (X = 3.3, 5, 12, 15, 24, 36, 48)
E183223-A121-UL-1
Supplies
Switching Power MP450-2KSX#-AG
E183223-A118-UL-1
Supply
Switching Power HRPX-200-Y (X = G or blank for marketing; Y = E183223-A120-UL-1
Supply
3.3, 5, 7.5, 12, 15, 24, 36, 48 for output voltage)
Switching Power NEx-35y (x = S, D,T; y = -5, -12, -15, -24, -48, E183223-A52-UL-2
Supply (For Built- A, B, C, D), SCP-35-12, SCP-35-24
In)
Switching Power NEx-75y (x = S, D, T; y = -5, -12, -15, -24, -48, E183223-A57-UL-2
Supply (For Built- A, B, C or D), SCP-75-12, SCP-75-24
In)
Switching Power NEx-50y (x = S, D, T; y = -5, -12, -15, -24, -48, E183223-A56-UL-2
Supply (For Built- A, B, C or D), SCP-50-12, SCP-50-24
In)
Switching Power HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, E183223-A123-UL-1
Supply
15, 24, 36, 48)
File
E183223
Index
Volume
Page
Date:
X1
6
18-May-10
Issue Date:
2010-05-19
Page 1 of 2
Report Reference #
E183223-A123-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ2, QQGQ8
Test Procedure:
Product:
Model/Type Reference:
Component Recognition
Switching Power Supply
HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48)
Rating(s):
Input: 100-240Vac, 50/60Hz, 6.0A
Output:
HRPX-450-3.3: +3.3Vdc/90A
HRPX-450-5: +5Vdc/90A
HRPX-450-7.5: +7.5Vdc/60A
HRPX-450-12: +12Vdc/37.5A
HRPX-450-15: +15Vdc/30A
HRPX-450-24: +24Vdc/18.8A
HRPX-450-36: +36Vdc/12.5A
HRPX-450-48: +48Vdc/9.5A
UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information Technology
Equipment - Safety - Part 1: General Requirements)
Standards:
Applicant Name and
Address:
MEAN WELL ENTERPRISES CO LTD
28 WU-CHUAN 3RD RD
WUGU INDUSTRIAL PARK
TAIPEI HSIEN
248 TAIWAN
This Report includes the following parts, in addition to this cover page:
1. Specific Inspection Criteria
2. Specific Technical Criteria
3. Clause Verdicts
4. Critical Components
5. Test Results
6. National Differences
7. Enclosures
Copyright © 2010
Issue Date:
2010-05-19
Page 2 of 2
Report Reference #
E183223-A123-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow -Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow -Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow -Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Any information and documentation provided to you involving UL Mark services are provided on behalf of Underwriters Laboratories
Inc(ULI) or any authorized license of ULI.
Test Report By:
Reviewed By:
Joyce Liang
Project Engineer
Underwriters Laboratories of Canada Inc.
Sam Fu
Project Engineer
Underwriters Laboratories Taiwan Co., Ltd.
Copyright © 2010
Issue Date:
2010-05-19
Page 1 of 70
Report Reference #
E183223-A123-UL-1
SPECIFIC INSPECTION CRITERIA
BA1.0
Special Instructions to UL Representative
BA1.1
Inspect the transformer(s) listed in BD1.1 per AA1.1- (C). When the tests are conducted at other
location, inspect test record and specification sheet provided by the component manufacturer.
Verify the specification sheet indicates 100% routine test specified in BD1.1 be conducted at the
component manufacturer.
BB1.0
Supporting Documentation
BB1.1
The following documents located at the beginning of this Procedure supplement the requirements
of this Test Report:
A. Authorization - The Authorization page may include additional Factory Identification Code
markings.
B. Generic Inspection Instructions i.
Part AC details important information which may be applicable to products covered by this
Procedure. Products described in this Test Report must comply with any applicable items
listed unless otherwise stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this
Procedure. Products described in this Test Report must comply with any applicable items
listed unless otherwise stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the
technical standard used to investigate these products. Products are permitted to bear only
the Certification Mark(s) corresponding to the countries for which it is certified, as indicated
in each Test Report.
BC1.0
Markings and instructions
BC1.1
The following markings and instructions are provided as indicated.
BC1.2
All clause references are from UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology
Equipment - Safety - Part 1: General Requirements).
Standard
Clause
Clause Title
Marking or Instruction Details
1.7.1
Power rating Ratings
Ratings (voltage, frequency/dc, current)
Power rating Company
identification
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
Power rating Model
Model Number
1.7.6
Fuses - NonUnambiguous reference to service documentation for instructions for
operator
replacement of fuses replaceable only by service personnel
access/solderedin fuses
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Fuses - Rating
Page 2 of 70
Report Reference #
E183223-A123-UL-1
Rated current and voltage and type located on or adjacent to fuse or
fuseholder.
BD1.0
Production-Line Testing Requirements
BD1.1
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Test
Potential
Model
Component
Test
V dc Time, s
Test probe location
HRPXTransformer
450-Y
(T1)
(X=G or
blank;
Y=3.3, 5,
7.5, 12,
15, 24, 36,
48)
N/A
Primary to Secondary
3000 424
2
1
HRPXTransformer
450-Y
(T900 when
(X=G or
provided)
blank;
Y=3.3, 5,
7.5, 12,
15, 24, 36,
48)
N/A
Primary to Secondary
3000 424
2
1
BD1.2
Earthing Continuity Test Exemptions - This
test is not required for the following models:
--
BD1.3
Electric Strength Test Exemptions - This test
is not required for the following models:
--
BD1.4
Electric Strength Test Component
Exemptions - The following solid-state
components may be disconnected from the
remainder of the circuitry during the
performance of this test:
--
BE1.0
V
rms
Removable Parts
Sample and Test Specifics for Follow-Up Tests at UL
BE1.1
Model
--
TRF No. IECEN60950_1C
Component
--
Material
--
Test
--
Underwriters Laboratories Inc.
Sample(s)
--
Test
Specifics
--
Issue Date:
2010-05-19
Page 3 of 70
Report Reference #
E183223-A123-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1:2005 (2nd Edition)
Information technology equipment - Safety Part 1: General requirements
Report Reference No ..................... : E183223-A123-UL-1
Compiled by ................................. : Joyce Liang
Reviewed by ................................. : Sam Fu
Date of issue ................................ : 2010-05-19
Standards ..................................... : UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Test procedure .............................. : Component Recognition
Non-standard test method ............. : N/A
Test item description .................... : Switching Power Supply
Trademark .................................... : None
Model and/or type reference .......... : HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48)
Rating(s) ...................................... : Input: 100-240Vac, 50/60Hz, 6.0A
Output:
HRPX-450-3.3: +3.3Vdc/90A
HRPX-450-5: +5Vdc/90A
HRPX-450-7.5: +7.5Vdc/60A
HRPX-450-12: +12Vdc/37.5A
HRPX-450-15: +15Vdc/30A
HRPX-450-24: +24Vdc/18.8A
HRPX-450-36: +36Vdc/12.5A
HRPX-450-48: +48Vdc/9.5A
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 4 of 70
Report Reference #
E183223-A123-UL-1
Particulars: test item vs. test requirements
Equipment mobility ................................................: for building-in
Connection to the mains ........................................: To be evaluated in end product
Operating condition ...............................................: continuous
Over voltage category ...........................................: OVC II
Mains supply tolerance (%) ....................................: +10%, -10% (Declared by Manufacturer)
Tested for IT power systems ..................................: No
IT testing, phase-phase voltage (V) ........................: N/A
Class of equipment ...............................................: Class I (earthed)
Mass of equipment (kg) .........................................: 1.1Kg
Pollution degree ....................................................: PD 2
IP protection class .................................................: IP X0
Possible test case verdicts:
- test case does not apply to the test object .............: N / A
- test object does meet the requirement ..................: Pass
- test object does not meet the requirement ............: Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 5 of 70
Report Reference #
E183223-A123-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
The devices are AC/DC switching power supplies. Each consists of electronic components
mounted on PWBs enclosed in a metal enclosure. Each has two terminal blocks and a DC fan.
CC1.0
Model Differences
CC1.1
All models have identical schematic and PWB layout.
Models with different X in model number are identical except for model designation.
Mocdel with different Y in model number are identical except for transformer T1 secondary and
some secondary components. See Enclosure ID 5-01 for detailed model differences.
CD1.0
Additional Information
CD1.1
N/A
CE1.0
Technical Considerations
CE1.2
The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 50°C
CE1.3
The means of connection to the mains supply is: To be evaluated in end product
CE1.4
The product is intended for use on the following power systems: TN
CE1.5
The equipment disconnect device is considered to be: To be evaluated in end product.
CE1.13
The following are available from the Applicant upon request: Specific data sheets for LED
indicators that are class I and operate at wavelength in the 400-710 nm range., Installation
(Safety) Instructions / Manual
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
When installed in an end-product, consideration must be given to the following:
CF1.2
The following Production-Line tests are conducted for this product: Electric Strength, Earthing
Continuity
CF1.3
The end-product Electric Strength Test is to be based upon a maximum working voltage of:
Primary-SELV: 303 Vrms, 480 Vpk, Primary-Earthed Dead Metal: 303 Vrms, 480 Vpk
CF1.5
The following secondary output circuits are SELV: All outputs
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 6 of 70
Report Reference #
E183223-A123-UL-1
CF1.6
The following secondary output circuits are at hazardous energy levels: All outputs
CF1.10
The following output terminals were referenced to earth during performance testing: Transformer
T1 (pin FL2 or output -V); Transformer T900 (pin 7, 8 or AUXG).
CF1.11
The power supply terminals and/or connectors are: Not investigated for field wiring
CF1.12
The maximum investigated branch circuit rating is: 20 A
CF1.13
The investigated Pollution Degree is: 2
CF1.15
Proper bonding to the end-product main protective earthing termination is: Required
CF1.16
An investigation of the protective bonding terminals has: Been conducted
CF1.17
The following input terminals/connectors must be connected to the end-product supply neutral:
Terminal AC/N from input terminal block TB1.
CF1.18
The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2
insulation system with the indicated rating greater than Class A (105°C): T1 (Class B) & T900
(Class B)
CF1.19
The following end-product enclosures are required: Mechanical, Electrical, Fire
CF1.20
The following components require special consideration during end-product Thermal (Heating)
tests due to the indicated maximum temperature measurements during component-level testing:
ZNR1 body
CF2.0
Terminal FG from the input terminal block TB1 shall be properly bonded to the protective
grounding terminal of the end product and the ground traces of the PWB shall be investigated
according to clause 2.6.3.4.
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 7 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
1
GENERAL
Pass
1.5
Components
Pass
1.5.1
General
Pass
1.5.2
Result - Remark
Verdict
Comply with IEC 60950 or relevant component
standard
(see appended table 1.5.1)
Pass
Evaluation and testing of components
Components certified to IEC
harmonized standard and
checked for correct
application. Components, for
which no relevant IECStandard
Pass
exist, have been tested under
the conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
Components not certified are
used in accordance with
their ratings and they comply
with applicable parts of IEC
60950-1 and the relevant
component Standard.
1.5.3
Thermal controls
Thermal Controls comply with
Annex K, see Annex K Thermal Controls.
Pass
1.5.4
Transformers
Transformers used are
suitable for their intended
applications and comply with
relevant parts of this standard
and particularly Annex C.
Pass
1.5.5
Interconnecting cables
No interconnecting cables
provided
1.5.6
Capacitors bridging insulation
Line-to-Neutral capacitors are
subclass X1 or X2.
Primary-t o-earth capacitors are
subclass Y1 or Y2.
Bridging capacitor C31 is
subclass Y1
Pass
1.5.7
Resistors bridging insulation
Resistors only bridge
functional insulation.
Pass
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
1.5.7.2
Resistors bridging double or reinforced insulation
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
N/A
Pass
N/A
Issue Date:
2010-05-19
Page 8 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
between a.c. mains and other circuits
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
1.5.7.4
Accessible parts
To be evaluated in end
product.
N/A
1.5.8
Components in equipment for IT power systems
Not for use on IT systems.
N/A
1.5.9
Surge suppressors
Pass
1.5.9.1
General
Pass
1.5.9.2
Protection of VDRs
1.5.9.3
Bridging of functional insulation by a VDR
1.5.9.4
Bridging of basic insulation by a VDR
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR
N/A
1.6
Power interface
Pass
1.6.1
AC power distribution systems
TN power system
Pass
1.6.2
Input current
The steady state input current
of the equipment did not
exceed the RATED CURRENT
by more than 10% under
NORMAL LOAD.
(see appended table 1.6.2)
Pass
1.6.3
Voltage limit of hand-held equipment
1.6.4
Neutral conductor
TRF No. IECEN60950_1C
N/A
Fuse FS1 rated F8A/250V is
used before the VDR.
Pass
Pass
Only functional insulation is
bridged by VDR.
N/A
N/A
Pass
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 9 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
1.7
Marking and instructions
1.7.1
Power rating
Verdict
Pass
Rating marking readily visible
to operator
Rated voltage(s) or voltage range(s) (V).............. : 100-240Vac
Symbol for nature of supply, for d.c. only............. :
Pass
Pass
N/A
Rated frequency or rated frequency range (Hz)... : 50/60 Hz.
Pass
Rated current (mA or A)..................................... : 6.0A
Pass
Manufacturer's name or trademark or identification Mean Well or E183223
mark ................................................................. :
Pass
Model identification or type reference.................. : HRPX-450-Y (X=G or blank;
Y=3.3, 5, 7.5, 12, 15, 24, 36,
48).
Pass
Symbol for Class II equipment only ..................... :
N/A
Other markings and symbols .............................. : Additional symbols do not give
rise to misunderstanding.
Pass
1.7.2
Safety instructions and marking
Pass
1.7.2.1
General
1.7.2.2
Disconnect devices
To be evaluated in the end
product.
N/A
1.7.2.3
Overcurrent protective device
To be evaluated in the end
product
N/A
1.7.2.4
IT Power distribution systems
N/A
1.7.2.5
Operator access with a tool
N/A
1.7.2.6
Ozone
N/A
1.7.3
Short duty cycles
N/A
1.7.4
Supply voltage adjustment ................................. : Auto-ranging.
N/A
Method and means of adjustment; reference to
installation instructions ....................................... :
N/A
1.7.5
Power outlets on the equipment ......................... : No standard power outlets are
provided.
N/A
1.7.6
Fuse identification (marking, special fusing
FS1, 8A/250V
characteristics, cross-reference)......................... :
1.7.7
Wiring terminals
1.7.7.1
Protective earthing and bonding terminals........... : Protective earthing to be
evaluated in end product.
N/A
1.7.7.2
Terminal for a.c. mains supply conductors
N/A
TRF No. IECEN60950_1C
Operating/safety instructions
made available to the user.
Pass
To be evaluated in end
product.
Terminals intended for
connection of the primary
Underwriters Laboratories Inc.
Pass
N/A
Issue Date:
2010-05-19
Page 10 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
power neutral conductor
indicated by the capital letter
N.
Marking not placed on any part
which might be removed when
conductors are being
connected.
The suitability of the terminals
for connection to the AC Mains
supply shall be evaluated in
the end product.
1.7.7.3
Terminals for d.c. mains supply conductors
1.7.8
Controls and indicators
Pass
1.7.8.1
Identification, location and marking ..................... : The function of controls
affecting safety is obvious
regardless of language.
Pass
1.7.8.2
Colours ............................................................. : A green LED is illuminated
when the unit is operating.
Pass
1.7.8.3
Symbols according to IEC 60417 ........................ :
N/A
1.7.8.4
Markings using figures ....................................... :
N/A
1.7.9
Isolation of multiple power sources ..................... : There is only one connection
to hazardous voltages.
N/A
1.7.10
Thermostats and other regulating devices ........... : No adjustable thermostats or
similar regulating devices.
N/A
1.7.11
Durability
All markings provided on UL
Recognized Component labels
suitable for surface they are
applied upon and meet the
durability test.
Pass
1.7.12
Removable parts
No marking is located on (a)
removable part(s).
Pass
1.7.13
Replaceable batteries ........................................ : No batteries
1.7.14
N/A
N/A
Language(s)...................................................... :
-
Equipment for restricted access locations............ :
N/A
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 11 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
2
PROTECTION FROM HAZARDS
Pass
2.1
Protection from electric shock and energy hazards
Pass
2.1.1
Protection in operator access areas
To be evaluated in end
product.
Pass
2.1.1.1
Access to energized parts
For building-in. Accessibility is
to be evaluated in end product.
Pass
Test by inspection ............................................. :
N/A
Test with test finger (Figure 2A).......................... :
N/A
Test with test pin (Figure 2B).............................. :
N/A
Test with test probe (Figure 2C) ......................... :
N/A
2.1.1.2
Battery compartments
N/A
2.1.1.3
Access to ELV wiring
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)........................ :
-
2.1.1.4
Access to hazardous voltage circuit wiring
N/A
2.1.1.5
Energy hazards ................................................. : The output of the power
supplies presents an energy
hazard. No operator access
permitted.
To be evaluated in end
product.
N/A
2.1.1.6
Manual controls
N/A
2.1.1.7
Discharge of capacitors in equipment
Measured voltage (V); time-constant (s).............. : line-to-line:
V0 (original V)=364pk;
37%V0=135 V; Voltage at 1
second = 0 V
2.1.1.8
Pass
-
Energy hazards - d.c. mains supply
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the mains supply :
N/A
2.1.1.9
Audio amplifiers ................................................. :
N/A
2.1.2
Protection in service access areas
N/A
2.1.3
Protection in restricted access locations
N/A
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 12 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
2.2
SELV circuits
Pass
2.2.1
General requirements
Pass
2.2.2
Voltages under normal conditions (V).................. : Not exceed 42,4 V peak, or 60
V d.c.
Pass
2.2.3
Voltages under fault conditions (V) ..................... : Not exceed 42,4 V peak, or 60
V d.c. for longer than 200 ms
and moreover, not exceed 71
V peak or 120 V d.c.
Pass
2.2.4
Connection of SELV circuits to other circuits ....... : SELV connected to limited
current circuit.
Pass
2.3
TNV circuits
2.3.1
Limits
N/A
No TNV presents
N/A
Type of TNV circuits .......................................... :
-
2.3.2
Separation from other circuits and from accessible
parts
N/A
2.3.2.1
General requirements
N/A
2.3.2.2
Protection by basic insulation
N/A
2.3.2.3
Protection by earthing
N/A
2.3.2.4
Protection by other constructions ........................ :
N/A
2.3.3
Separation from hazardous voltages
N/A
Insulation employed........................................... :
2.3.4
Connection of TNV circuits to other circuits
Insulation employed........................................... :
2.3.5
Test for operating voltages generated externally
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
N/A
N/A
Issue Date:
2010-05-19
Page 13 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
2.4
Limited current circuits
2.4.1
General requirements
For secondary of Bridging
Capacitor C31
Pass
2.4.2
Limit values
0.7 mA peak
Pass
Pass
Frequency (Hz) ................................................. : 60
-
Measured current (mA) ...................................... : 0.59
-
Measured voltage (V) ........................................ : 1.18
-
Measured circuit capacitance (nF or uF) ............. : 2200pF
-
2.4.3
Connection of limited current circuits to other
circuits
Pass
2.5
Limited power sources
N/A
a) Inherently limited output
N/A
b) Impedance limited output
N/A
c) Regulating network limited output under normal
operating and single fault condition
N/A
d) Overcurrent protective device limited output
N/A
Max. output voltage (V), max. output current (A),
max. apparent power (VA) ................................. :
-
Current rating of overcurrent protective device (A):
-
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 14 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
2.6
Provisions for earthing and bonding
2.6.1
Protective earthing
To be evaluated in end
Product.
2.6.2
Functional earthing
Functional earthing separated
from Hazardous voltage by
reinforced insulation.
Pass
2.6.3
Protective earthing and protective bonding
conductors
Tobe evaluated in end product
N/A
2.6.3.1
General
N/A
2.6.3.2
Size of protective earthing conductors
N/A
Pass
Rated current (A), cross-sectional area (mm²),
AWG ................................................................ :
2.6.3.3
Verdict
N/A
-
Size of protective bonding conductors
N/A
Rated current (A), cross-sectional area mm²), AWG
........................................................................ :
-
2.6.3.4
Resistance of earthing conductors and their
Test current 40A:
terminations; resistance (ohm), voltage drop (V),
Ground pin - chassis: Voltage
test current (A), duration (min)............................ : drop 0.43V
N/A
2.6.3.5
Colour of insulation ............................................ : Not used.
N/A
2.6.4
Terminals
N/A
2.6.4.1
General
N/A
2.6.4.2
Protective earthing and bonding terminals
N/A
To be evaluated in end
product.
Rated current (A), type, nominal thread diameter
(mm)................................................................. :
-
2.6.4.3
Separation of the protective earthing conductor
from protective bonding conductors
2.6.5
Integrity of protective earthing
2.6.5.1
Interconnection of equipment
N/A
2.6.5.2
Components in protective earthing conductors and
protective bonding conductors
N/A
2.6.5.3
Disconnection of protective earth
N/A
2.6.5.4
Parts that can be removed by an operator
N/A
2.6.5.5
Parts removed during servicing
N/A
2.6.5.6
Corrosion resistance
N/A
2.6.5.7
Screws for protective bonding
2.6.5.8
Reliance on telecommunication network or cable
TRF No. IECEN60950_1C
N/A
To be evaluated at endproduct.
Metal thickness at least twice
the pitch of the screw.
Underwriters Laboratories Inc.
N/A
N/A
N/A
Issue Date:
2010-05-19
Page 15 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
distribution system
2.7
Overcurrent and earth fault protection in primary circuits
Pass
2.7.1
Basic requirements
Pass
Protective devices are
integrated in the equipment.
Instructions when protection relies on building
installation
N/A
2.7.2
Faults not covered in 5.3.7
Protection from faults not
covered in 5.3 are provided by
end installation.
Pass
2.7.3
Short-circuit backup protection
The building installation is
considered as providing shortcircuit backup protection.
Pass
2.7.4
Number and location of protective devices .......... : One protective device (Fuse
FS1) in the "LIVE" phase
2.7.5
Protection by several devices
2.7.6
Warning to service personnel ............................. :
N/A
2.8
Safety interlocks
N/A
2.8.1
General principles
N/A
2.8.2
Protection requirements
N/A
2.8.3
Inadvertent reactivation
N/A
2.8.4
Fail-safe operation
N/A
2.8.5
Moving parts
N/A
2.8.6
Overriding
N/A
2.8.7
Switches and relays
N/A
2.8.7.1
Contact gaps (mm) ............................................ :
N/A
2.8.7.2
Overload test
N/A
2.8.7.3
Endurance test
N/A
2.8.7.4
Electric strength test
N/A
2.8.8
Mechanical actuators
N/A
TRF No. IECEN60950_1C
Only one protective device is
provided.
Underwriters Laboratories Inc.
Pass
N/A
Issue Date:
2010-05-19
Page 16 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
2.9
Electrical insulation
2.9.1
Properties of insulating materials
Natural rubber, materials
containing asbestos and
hygroscopic materials are not
used as insulation.Adequate
clearances and creepage
distances.
Pass
2.9.2
Humidity conditioning
Electric strength test was
conducted after the humidity
treatment.
Pass
Pass
Relative humidity (%), temperature (°C) .............. : 95%, 40°C, 48 hours.
2.9.3
Grade of insulation
2.9.4
Separation from hazardous voltages
Adequate level of safety
insulation is provided and
maintained to comply with the
requirements of this standard.
Method(s) used ................................................. : Primary circuit separated from
Secondary circuit by double
insulation or reinforced
insulation.
TRF No. IECEN60950_1C
Verdict
Underwriters Laboratories Inc.
Pass
Pass
-
Issue Date:
2010-05-19
Page 17 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
2.10
Clearances, creepage distances and distances through insulation
Pass
2.10.1
General
Pass
2.10.1.1
Frequency......................................................... : 50/60Hz
Pass
2.10.1.2
Pollution degrees ............................................... : Pollution Degree 2
Pass
2.10.1.3
Reduced values for functional insulation
N/A
2.10.1.4
Intervening unconnected conductive parts
N/A
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6
Special separation requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
2.10.2.1
General
Pass
2.10.2.2
RMS working voltage
Pass
2.10.2.3
Peak working voltage
Pass
2.10.3
Clearances
2.10.3.1
General
Pass
2.10.3.2
Mains transient voltages
Pass
a) AC mains supply ........................................... : 2500V
Pass
Pollution degree 2 applicable.
See appended table 2.10.3
and 2.10.4
See appended table 2.10.3
and 2.10.4
Verdict
Pass
Pass
b) Earthed d.c. mains supplies............................ :
N/A
c) Unearthed d.c.. mains supplies ....................... :
N/A
d) Battery operation ........................................... :
N/A
2.10.3.3
Clearances in primary circuits
(see appended table 2.10.3
and 2.10.4)
Pass
2.10.3.4
Clearances in secondary circuits
Compliance criteria for 5.3.4.
Pass
2.10.3.5
Clearances in circuits having starting pulses
N/A
2.10.3.6
Transients from a.c. mains supply....................... :
N/A
2.10.3.7
Transients from d.c. mains supply....................... :
N/A
2.10.3.8
Transients from telecommunication networks and
cable distribution systems .................................. :
N/A
2.10.3.9
Measurement of transient voltage levels
N/A
a) Transients from a mains supply
N/A
For an a.c. mains supply .................................... :
N/A
For a d.c. mains supply ...................................... :
N/A
b) Transients from a telecommunication network
N/A
2.10.4
Creepage distances
TRF No. IECEN60950_1C
(see appended table 2.10.3
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 18 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
and 2.10.4)
2.10.4.1
General
Pass
2.10.4.2
Material group and comparative tracking index
Pass
CTI tests ........................................................... : Material Group IIIa or IIIb
assumed unless otherwise
indicated. 100 <= CTI < 175
-
2.10.4.3
Minimum creepage distances
Pass
2.10.5
Solid insulation
Pass
2.10.5.1
General
Pass
2.10.5.2
Distances through insulation
2.10.5.3
Insulating compound as solid insulation
2.10.5.4
Semiconductor devices
2.10.5.5
Cemented joints
2.10.5.6
Thin sheet material - General
Pass
2.10.5.7
Separable thin sheet material
Pass
UL recognized R/C (FPQU2)
optocouplers used.
Insulation sheet provides basic
insulation only.
N/A
UL recognized R/C (FPQU2)
optocouplers used.
Pass
N/A
Number of layers (pcs)....................................... : 2 layers insulation tape wrap
transformer outside. 2 layers
insulation tape between
primary and secondary of
transformers T1 and T900.
2.10.5.8
Non-separable thin sheet material
2.10.5.9
Thin sheet material - standard test procedure
UL recognized R/C triple
insulated winding wire used
T2.
Electric strength test .......................................... :
2.10.5.10
Pass
Thin sheet material - alternative test procedure
Electric strength test .......................................... : (see appended table 5.2)
-
N/A
N/A
Pass
-
2.10.5.11
Insulation in wound components
2.10.5.12
Wire in wound components
N/A
Working voltage ................................................ :
N/A
a) Basic insulation not under stress .................... :
N/A
b) Basic, supplementary, reinforced insulation..... :
N/A
c) Compliance with Annex U .............................. :
N/A
Two wires in contact inside wound component;
N/A
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 19 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
angle between 45° and 90° ................................ :
2.10.5.13
Wire with solvent-based enamel in wound
components
N/A
Electric strength test .......................................... :
2.10.5.14
-
Routine test
N/A
Additional insulation in wound components
N/A
Working voltage ................................................ :
N/A
- Basic insulation not under stress ...................... :
N/A
- Supplementary, reinforced insulation ................ :
N/A
2.10.6
Construction of printed boards
Pass
2.10.6.1
Uncoated printed boards
2.10.6.2
Coated printed boards
N/A
2.10.6.3
Insulation between conductors on the same inner
surface of a printed board
N/A
2.10.6.4
Insulation between conductors on different layers
of a printed board
N/A
Distance through insulation
N/A
Number of insulation layers (pcs)........................ :
N/A
(see appended table 2.10.3
and 2.10.4)
2.10.7
Component external terminations
2.10.8
Tests on coated printed boards and coated
components
N/A
2.10.8.1
Sample preparation and preliminary inspection
N/A
2.10.8.2
Thermal conditioning
N/A
2.10.8.3
Electric strength test
N/A
2.10.8.4
Abrasion resistance test
N/A
2.10.9
Thermal cycling
N/A
2.10.10
Test for Pollution Degree 1 environment and
insulating compound
N/A
2.10.11
Tests for semiconductor devices and cemented
joints
N/A
2.10.12
Enclosed and sealed parts
N/A
TRF No. IECEN60950_1C
(see appended table 2.10.3
and 2.10.4)
Pass
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 20 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
3
WIRING, CONNECTIONS AND SUPPLY
Pass
3.1
General
Pass
3.1.1
Current rating and overcurrent protection
Pass
3.1.2
Protection against mechanical damage
N/A
3.1.3
Securing of internal wiring
N/A
3.1.4
Insulation of conductors
N/A
3.1.5
Beads and ceramic insulators
N/A
3.1.6
Screws for electrical contact pressure
All electrical screw
connections are by metal
screw with more than 2
threads into a metal plate.
3.1.7
Insulating materials in electrical connections
No contact pressure through
insulating material.
N/A
3.1.8
Self-tapping and spaced thread screws
No thread-cutting or space
thread screws used.
N/A
3.1.9
Termination of conductors
3.1.10
Result - Remark
Pass
Pass
10 N pull test
Checked by Inspection.
Sleeving on wiring
Heat shrinkable sleeving used.
TRF No. IECEN60950_1C
Verdict
Underwriters Laboratories Inc.
N/A
Pass
Issue Date:
2010-05-19
Page 21 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
3.2
Connection to mains supply
3.2.1
Means of connection
To be evaluated in end
product.
N/A
3.2.1.1
Connection to an a.c. mains supply
To be evaluated in end
product.
N/A
3.2.1.2
Connection to a d.c. mains supply
N/A
3.2.2
Multiple supply connections
N/A
3.2.3
Permanently connected equipment
N/A
To be evaluated in end
product.
Number of conductors, diameter of cable and
conduits (mm) ................................................... :
N/A
-
3.2.4
Appliance inlets
No appliance inlet.
N/A
3.2.5
Power supply cords
A power supply cord is not
provided.
N/A
3.2.5.1
AC power supply cords
N/A
Type................................................................. :
-
Rated current (A), cross-sectional area (mm²),
AWG ................................................................ :
-
3.2.5.2
DC power supply cords
N/A
3.2.6
Cord anchorages and strain relief
N/A
Mass of equipment (kg), pull (N)......................... :
-
Longitudinal displacement (mm) ......................... :
-
3.2.7
Protection against mechanical damage
N/A
3.2.8
Cord guards
N/A
3.2.9
Diameter of minor dimension D (mm); test mass (g)
........................................................................ :
-
Radius of curvature of cord (mm)........................ :
-
Supply wiring space
TRF No. IECEN60950_1C
To be evaluated in end
product.
Underwriters Laboratories Inc.
N/A
Issue Date:
2010-05-19
Page 22 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
3.3
Wiring terminals for connection of external conductors
3.3.1
Wiring terminals
3.3.2
Connection of non-detachable power supply cords
3.3.3
Screw terminals
3.3.4
Conductor sizes to be connected
For building-in. To be
evaluated in end product.
Pass
N/A
N/A
Pass
To be evaluated in end
product.
Rated current (A), cord/cable type, cross-sectional
area (mm²) ........................................................ :
3.3.5
Verdict
N/A
-
Wiring terminal sizes
Pass
Rated current (A), type and nominal thread
R/C (XCFR2) terminal bloack
diameter (mm)................................................... : (TB1) rated 300 V ac, 20 A
each pin.
-
3.3.6
Wiring terminals design
Terminals are mounted such
that they do not become loose,
place stress on internal wiring,
or reduce creepage and
clearances below those
prescribed in 2.9.
Pass
3.3.7
Grouping of wiring terminals
All mains supply and earthing
terminals in close proximity.
Pass
3.3.8
Stranded wire
TRF No. IECEN60950_1C
N/A
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 23 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
3.4
Disconnection from the mains supply
3.4.1
General requirement
To be evaluated in end
product.
N/A
3.4.2
Disconnect devices
To be evaluated in end product
N/A
3.4.3
Permanently connected equipment
To be evaluated in end
product.
N/A
3.4.4
Parts which remain energized
To be evaluated in end
product.
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10
Interconnected equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
Pass
3.5.1
General requirements
Pass
3.5.2
Types of interconnection circuits......................... : Interconnection circuits are
SELV CIRCUITS.
Pass
3.5.3
ELV circuits as interconnection circuits
N/A
3.5.4
Data ports for additional equipment
N/A
4
PHYSICAL REQUIREMENTS
4.1
Stability
N/A
Pass
N/A
Angle of 10°
For building-in
Test force (N).................................................... :
TRF No. IECEN60950_1C
Verdict
Underwriters Laboratories Inc.
N/A
N/A
Issue Date:
2010-05-19
Page 24 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
4.2
Mechanical strength
Pass
4.2.1
General
Pass
4.2.2
Steady force test, 10 N
Pass
4.2.3
Steady force test, 30 N
Tested on chassis. No hazard
as a result of the 30 N test.
4.2.4
Steady force test, 250 N
For building-in. To be
evaluated in end product.
4.2.5
Impact test
N/A
Fall test
N/A
Swing test
N/A
4.2.6
Drop test; height (mm) ....................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified.......................... :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ...... :
N/A
TRF No. IECEN60950_1C
Result - Remark
Underwriters Laboratories Inc.
Verdict
Pass
N/A
Issue Date:
2010-05-19
Page 25 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
4.3
Design and construction
4.3.1
Edges and corners
4.3.2
Handles and manual controls; force (N) .............. :
N/A
4.3.3
Adjustable controls
N/A
4.3.4
Securing of parts
4.3.5
Connection by plugs and sockets
N/A
4.3.6
Direct plug-in equipment
N/A
Torque .............................................................. :
N/A
Compliance with the relevant mains plug standard:
N/A
Pass
All edges and corners are
judged to be sufficiently well
rounded so as not to constitute
a hazard. Judged by
inspection.
No loosening of parts impairing
creep age distances or
clearances over
supplementary or reinforced
insulation is likely to occur.
Pass
Pass
4.3.7
Heating elements in earthed equipment
No heating elements.
N/A
4.3.8
Batteries
No batteries
N/A
- Overcharging of a rechargeable battery
N/A
- Unintentional charging of a non-rechargeable
battery
N/A
- Reverse charging of a rechargeable battery
N/A
- Excessive discharging of any battery
N/A
4.3.9
Oil and grease
The insulation of the internal
wiring is not exposed to oil,
grease, etc.
N/A
4.3.10
Dust, powders, liquids and gases
N/A
4.3.11
Containers for liquids or gases
N/A
4.3.12
Flammable liquids ............................................. :
N/A
Quantity of liquid (l)............................................ :
N/A
Flash point (°C) ................................................. :
N/A
4.3.13
Radiation
Pass
4.3.13.1
General
N/A
4.3.13.2
Ionizing radiation
N/A
Measured radiation (pA/kg) ................................ :
-
Measured high-voltage (kV) ............................... :
-
Measured focus voltage (kV).............................. :
-
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 26 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
CRT markings ................................................... :
4.3.13.3
Verdict
-
Effect of ultraviolet (UV) radiation on materials
N/A
Part, property, retention after test, flammability
classification ..................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation....... :
N/A
4.3.13.5
Laser (including LEDs)
Contains only one visible
indicator LED (Class 1)
operating in the range of 400 700 nm wavelength. No
IEC60825-1 evaluation was
deemed necessary.
Laser class........................................................ : (For indicator LEDs, see above
statement.)
Pass
-
4.3.13.6
Other types ....................................................... :
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
4.4.2
Protection in operator access areas .................... :
N/A
4.4.3
Protection in restricted access locations .............. :
N/A
4.4.4
Protection in service access areas
N/A
4.5
Thermal requirements
Pass
4.5.1
General
Pass
4.5.2
Temperature tests
To be evaluated in end
product.
(see appended table 4.5)
Normal load condition per Annex L ..................... : See Annex L.
N/A
Pass
-
4.5.3
Temperature limits for materials
Pass
4.5.4
Touch temperature limits
Pass
4.5.5
Resistance to abnormal heat .............................. :
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
N/A
Issue Date:
2010-05-19
Page 27 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
4.6
Openings in enclosures
4.6.1
Top and side openings
N/A
For building-in, fire enclosure
to be provided in end product.
Dimensions (mm) .............................................. :
4.6.2
Verdict
N/A
-
Bottoms of fire enclosures
N/A
Construction of the bottom, dimensions (mm) ...... :
-
4.6.3
Doors or covers in fire enclosures
N/A
4.6.4
Openings in transportable equipment
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) .............................................. :
-
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
N/A
Conditioning temperature (°C), time (weeks) ....... :
-
4.7
Resistance to fire
Pass
4.7.1
Reducing the risk of ignition and spread of flame
Pass
Method 1, selection and application of components
wiring and materials
Pass
Method 2, application of all of simulated fault
condition tests
N/A
4.7.2
Conditions for a fire enclosure
N/A
4.7.2.1
Parts requiring a fire enclosure
4.7.2.2
Parts not requiring a fire enclosure
4.7.3
Materials
Pass
4.7.3.1
General
N/A
4.7.3.2
Materials for fire enclosures
4.7.3.3
Materials for components and other parts outside
fire enclosures
4.7.3.4
Materials for components and other parts inside fire All internal materials are rated
enclosures
V-2 or better or are mounted
on a PWB rated V-1 or better.
4.7.3.5
Materials for air filter assemblies
4.7.3.6
Materials used in high-voltage components
TRF No. IECEN60950_1C
For building-in, fire enclosure
to be provided in end product.
N/A
N/A
For building-in, fire enclosure
to be provided in end product.
N/A
N/A
Pass
N/A
No high-voltage components.
Underwriters Laboratories Inc.
N/A
Issue Date:
2010-05-19
Page 28 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
Pass
5.1
Touch current and protective conductor current
Pass
5.1.1
General
Pass
5.1.2
Configuration of equipment under test (EUT)
Pass
5.1.2.1
Single connection to an a.c. mains supply
Pass
5.1.2.2
Redundant multiple connections to an a.c. mains
supply
N/A
5.1.2.3
Simultaneous multiple connections to an a.c. mains
supply
N/A
5.1.3
Test circuit
Single phase equipment
intended only for connection to
star TN system.
Pass
5.1.4
Application of measuring instrument
Tested using D.1 measuring
instrument.
Pass
5.1.5
Test procedure
Pass
5.1.6
Test measurements
Pass
Supply voltage (V) ............................................. : 264V
-
Measured touch current (mA) ............................. : Max. 1.5 mA (with switch "e"
open)
Max. 0.18mA (with switch "e"
closed)
-
Max. allowed touch current (mA) ........................ : 3.5mA (with switch "e" open)
0.25mA (with switch "e"
closed)
-
Measured protective conductor current (mA) ....... : --
-
Max. allowed protective conductor current (mA) .. : --
-
5.1.7
Equipment with touch current exceeding 3,5 mA
N/A
5.1.7.1
General............................................................. :
N/A
5.1.7.2
Simultaneous multiple connections to the supply
N/A
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
N/A
5.1.8.2
Supply voltage (V) ............................................. :
-
Measured touch current (mA) ............................. :
-
Max. allowed touch current (mA) ........................ :
-
Summation of touch currents from
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
N/A
Issue Date:
2010-05-19
Page 29 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
telecommunication networks
a) EUT with earthed telecommunication ports...... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
N/A
5.2
Electric strength
5.2.1
General
(see appended table 5.2)
Pass
5.2.2
Test procedure
No insulation breakdown
detected during the test.
Pass
TRF No. IECEN60950_1C
Pass
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 30 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
(see appended table 5.3)
5.3.2
Motors
Fan motor evaluated as part of
component evaluation.
N/A
5.3.3
Transformers
Transformers are constructed
in accordance with the
applicable Clause and Annex
C.
Pass
5.3.4
Functional insulation.......................................... : Functional insulation complies
with the requirement (c).
Pass
5.3.5
Electromechanical components
N/A
5.3.6
Audio amplifiers in ITE ....................................... :
N/A
5.3.7
Simulation of faults
See table 5.3
5.3.8
Unattended equipment
The equipments do not have
any thermostats, temperature
limiters, or thermal cut-outs
which functioned during the
Heating Test.
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
No fire, emission of molten
metal or deformation was
noted during the tests.
Electric Strength tests
performed after abnormal and
fault tests.
Pass
5.3.9.1
During the tests
No fire, emission of molten
metal or deformation was
noted during the tests.
Pass
5.3.9.2
After the tests
Electric Strength tests
performed after abnormal and
fault tests.
Pass
TRF No. IECEN60950_1C
Result - Remark
Verdict
Pass
Underwriters Laboratories Inc.
Pass
Pass
Issue Date:
2010-05-19
Page 31 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
6.1
Protection of telecommunication network service persons, and users of other
equipment connected to the network, from hazards in the equipment
N/A
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1
Requirements
N/A
Supply voltage (V) ............................................. :
-
Current in the test circuit (mA)............................ :
-
6.1.2.2
Exclusions ........................................................ :
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
N/A
6.2.1
Separation requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1
Impulse test
N/A
6.2.2.2
Steady-state test
N/A
6.2.2.3
Compliance criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
N/A
Max. output current (A) ...................................... :
-
Current limiting method...................................... :
-
7
CONNECTION TO CABLE DISTRIBUTION SYSTEMS
N/A
7.1
General
N/A
7.2
Protection of cable distribution system servi ce persons, and users of other
equipment connected to the system, from hazardous voltages in the equipment
N/A
7.3
Protection of equipment users from overvoltages
on the cable distribution system
N/A
7.4
Insulation between primary circuits and cable
distribution systems
N/A
7.4.1
General
N/A
7.4.2
Voltage surge test
N/A
7.4.3
Impulse test
N/A
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 32 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
A
ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE
N/A
A.1
Flammability test for fire enclosures of movable equipment having a total mass
exceeding 18 kg, and of stationary equipment (see 4.7.3.2)
N/A
A.1.1
Samples ........................................................... :
-
Wall thickness (mm) .......................................... :
-
A.1.2
Conditioning of samples; temperature (°C) .......... :
N/A
A.1.3
Mounting of samples .......................................... :
N/A
A.1.4
Test flame (see IEC 60695-11-3)
N/A
Flame A, B, C or D ............................................ :
N/A
A.1.5
Test procedure
N/A
A.1.6
Compliance criteria
N/A
Sample 1 burning time (s) .................................. :
-
Sample 2 burning time (s) .................................. :
-
Sample 3 burning time (s) .................................. :
-
A.2
Flammability test for fire enclosures of movable equipment having a total mass not
exceeding 18 kg, and for material and components located inside fire enclosures
(see 4.7.3.2 and 4.7.3.4)
A.2.1
Samples, material.............................................. :
-
Wall thickness (mm) .......................................... :
-
A.2.2
Conditioning of samples; temperature (°C) .......... :
N/A
A.2.3
Mounting of samples .......................................... :
N/A
A.2.4
Test flame (see IEC 60695-11-4)
N/A
Flame A, B or C................................................. :
N/A
-
A.2.5
Test procedure
N/A
A.2.6
Compliance criteria
N/A
A.2.7
Sample 1 burning time (s) .................................. :
-
Sample 2 burning time (s) .................................. :
-
Sample 3 burning time (s) .................................. :
-
Alternative test acc. to IEC 60695-11-5, cl. 5 and 9
N/A
Sample 1 burning time (s) .................................. :
-
Sample 2 burning time (s) .................................. :
-
Sample 3 burning time (s) .................................. :
-
A.3
Hot flaming oil test (see 4.6.2)
N/A
A.3.1
Mounting of samples
N/A
A.3.2
Test procedure
N/A
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 33 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
A.3.3
Compliance criterion
N/A
B
ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see 4.7.2.2 and
5.3.2)
N/A
B.1
General requirements
N/A
Position............................................................. :
-
Manufacturer..................................................... :
-
Type................................................................. :
-
Rated values ..................................................... :
-
B.2
Test conditions
N/A
B.3
Maximum temperatures
N/A
B.4
Running overload test
N/A
B.5
Locked-rotor overload test
N/A
Test duration (days)........................................... :
-
Electric strength test: test voltage (V).................. :
-
B.6
Running overload test for d.c. motors in secondary
circuits
N/A
B.6.1
General
N/A
B.6.2
Test procedure
N/A
B.6.3
Alternative test procedure
N/A
B.6.4
Electric strength test; test voltage (V).................. :
N/A
B.7
Locked-rotor overload test for d.c. motors in secondary circuits
N/A
B.7.1
General
N/A
B.7.2
Test procedure
N/A
B.7.3
Alternative test procedure
N/A
B.7.4
Electric strength test; test voltage (V).................. :
N/A
B.8
Test for motors with capacitors
N/A
B.9
Test for three-phase motors
N/A
B.10
Test for series motors
N/A
Operating voltage (V)......................................... :
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
-
Issue Date:
2010-05-19
Page 34 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
C
ANNEX C, TRANSFORMERS (see 1.5.4 and 5.3.3)
Verdict
Pass
Position............................................................. : See appended table 1.5.1.
-
Manufacturer..................................................... : See appended table 1.5.1.
-
Type................................................................. : See appended table 1.5.1.
-
Rated values ..................................................... : See appended table 1.5.1.
-
Method of protection.......................................... : protection by regulating
network
-
C.1
Overload test
See appended table 5.3.
Pass
C.2
Insulation
(see appended table 5.2)
Pass
Protection from displacement of windings............ : Min. 3mm wide margin tape
provided on both sides of each
winding in Transformer T1.
Min. 3.3mm wide margin tape
provided on both sides of each
winding in Transformer T900.
Pass
D
ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see
5.1.4)
Pass
D.1
Measuring instrument
Pass
D.2
Alternative measuring instrument
N/A
E
ANNEX E, TEMPERATURE RISE OF A WINDING (see 1.4.13)
N/A
F
ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
(see 2.10 and Annex G)
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 35 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
G
ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM
CLEARANCES
N/A
G.1
Clearances
N/A
G.1.1
General
N/A
G.1.2
Summary of the procedure for determining
minimum clearances
N/A
G.2
Determination of mains transient voltage (V)
N/A
G.2.1
AC mains supply ............................................... :
N/A
G.2.2
Earthed d.c. mains supply .................................. :
N/A
G.2.3
Unearthed d.c. mains supply .............................. :
N/A
G.2.4
Battery operation............................................... :
N/A
G.3
Determination of telecommunication network
transient voltage (V) :......................................... :
N/A
G.4
Determination of required withstand voltage (V)
N/A
G.4.1
Mains transients and internal repetitive peaks ..... :
N/A
G.4.2
Transients from telecommunication networks ...... :
N/A
G.4.3
Combination of transients
N/A
G.4.4
Transients from cable distribution systems
N/A
G.5
Measurement of transient voltages (V)
N/A
G.6
Determination of minimum clearances ................ :
N/A
H
ANNEX H, IONIZING RADIATION (see 4.3.13)
N/A
J
ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see 2.6.5.6)
N/A
Metal(s) used .................................................... : Aluminum
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
-
Issue Date:
2010-05-19
Page 36 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
K
ANNEX K, THERMAL CONTROLS (see 1.5.3 and 5.3.8)
Pass
K.1
Making and breaking capacity
Pass
K.2
Thermostat reliability; operating voltage (V)......... :
N/A
K.3
Thermostat endurance test; operating voltage (V) :
N/A
K.4
Temperature limiter endurance; operating voltage
The two thermostats are UL
(V).................................................................... : R/C and was tested for 10000
cycles of operation during the
component evaluation.
K.5
Thermal cut-out reliability
K.6
Stability of operation
L
ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL
BUSINESS EQUIPMENT (see 1.2.2.1 and 4.5.2)
L.1
Typewriters
N/A
L.2
Adding machines and cash registers
N/A
L.3
Erasers
N/A
L.4
Pencil sharpeners
N/A
L.5
Duplicators and copy machines
N/A
L.6
Motor-operated files
N/A
L.7
Other business equipment
TRF No. IECEN60950_1C
Result - Remark
The two thermostats are is UL
R/C and was tested for 10000
cycles of operation during the
component evaluation.
Verdict
Pass
N/A
(see appended table 5.3)
Maximum rating load.
Underwriters Laboratories Inc.
Pass
Pass
Pass
Issue Date:
2010-05-19
Page 37 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
M
ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1)
N/A
M.1
Introduction
N/A
M.2
Method A
N/A
M.3
Method B
N/A
M.3.1
Ringing signal
N/A
M.3.1.1
Frequency (Hz) ................................................. :
-
M.3.1.2
Voltage (V)........................................................ :
-
M.3.1.3
Cadence; time (s), voltage (V) ............................ :
-
M.3.1.4
Single fault current (mA) .................................... :
-
M.3.2
Tripping device and monitoring voltage ............... :
N/A
M.3.2.1
Conditions for use of a tripping device or a
monitoring voltage
N/A
M.3.2.2
Tripping device
N/A
M.3.2.3
Monitoring voltage (V)........................................ :
N/A
N
ANNEX N, IMPULSE TEST GENERATORS (see 1.5.7.2, 1.5.7.3, 2.10.3.9, 6.2.2.1,
7.3.2, 7.4.3 and Clause G.5)
N/A
N.1
ITU -T impulse test generators
N/A
N.2
IEC 60065 impulse test generator
N/A
P
ANNEX P, NORMATIVE REFERENCES
Pass
Q
ANNEX Q, Voltage dependent resistors (VDRs) (see 1.5.9.1)
Pass
a) Preferred climatic categories .......................... : The VDR's used are UL R/C
components.
Pass
b) Maximum continuous voltage ......................... : VDR's used are rated for the
application
Pass
c) Pulse current ................................................. : The VDR's used are UL R/C
components.
Pass
TRF No. IECEN60950_1C
Result - Remark
Underwriters Laboratories Inc.
Verdict
Issue Date:
2010-05-19
Page 38 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
R
ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL
PROGRAMMES
N/A
R.1
Minimum separation distances for unpopulated
coated printed boards (see 2.10.6.2)
N/A
R.2
Reduced clearances (see 2.10.3)
N/A
S
ANNEX S, PROCEDURE FOR IMPULSE TESTING (see 6.2.2.3)
N/A
S.1
Test equipment
N/A
S.2
Test procedure
N/A
S.3
Examples of waveforms during impulse testing
N/A
T
ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see
1.1.2)
N/A
........................................................................ : IPX0
U
ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED
INSULATION (see 2.10.5.4)
........................................................................ :
Verdict
-
N/A
-
V
ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1)
Pass
V.1
Introduction
Pass
V.2
TN power distribution systems
Pass
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 39 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
W
ANNEX W, SUMMATION OF TOUCH CURRENTS
N/A
W.1
Touch current from electronic circuits
N/A
W.1.1
Floating circuits
N/A
W.1.2
Earthed circuits
N/A
W.2
Interconnection of several equipments
N/A
W.2.1
Isolation
N/A
W.2.2
Common return, isolated from earth
N/A
W.2.3
Common return, connected to protective earth
N/A
X
ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see
clause C.1)
Pass
X.1
Determination of maximum input current
Pass
X.2
Overload test procedure
Pass
Y
ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see 4.3.13.3)
N/A
Y.1
Test apparatus .................................................. :
N/A
Y.2
Mounting of test samples ................................... :
N/A
Y.3
Carbon-arc light-exposure apparatus .................. :
N/A
Y.4
Xenon-arc light-exposure apparatus ................... :
N/A
Z
ANNEX Z, OVERVOLTAGE CATEGORIES (see 2.10.3.2 and Clause G.2)
AA
ANNEX AA, MANDREL TEST (see 2.10.5.8)
TRF No. IECEN60950_1C
Result - Remark
Underwriters Laboratories Inc.
Verdict
Pass
N/A
Issue Date:
2010-05-19
Page 40 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
1.5.1
TABLE: list of critical components
Object/part No.
Manufacturer/
trademark
type/model
technical data
Product Category
CCN(s)
Required
Marks of
Conformity
Supplement ID
Enclosure cover
Various
Various
--
--
4-01
Enclosure base
various
various
--
--
4-01
Vent Openings (Side
Chassis)
Various
Various
--
--
Fan Opening (Front
Chassis)
Various
Various
--
--
Fan
Sanyo Denki Co Ltd
109P0412K3023
GPWV2
UL
Fan (Alternate)
Sanyo Denki Co Ltd
109P0412J3023
GPWV2
UL
Fan (Alternate)
Sanyo Denki Co Ltd
109P0412G3023
Aluminium, min. 1.2 mm thick,
secured to enclosure base by
screws. Measured overall 211
by 100.6 by 10 mm.
Aluminum, min. 2.0 mm thick.
Measured overall 218 by 105
by 40 mm.
Four rectangular openings
each measured overall 6.9 by
2.5 mm on both Left and Right
Chassis. One additional slot
opening measured overall 10
by 4.0mm on left Chassis
Measured overall 38 mm dia.,
consists of 3 concentric slot
rings, each measured max. 10
mm wide.
Rated 12Vdc, 0.55A, 21 CFM.
Outward airflow orientation.
Secured to the front Chassis by
screws. Fan leads provided
with min. 0.4mm thick tubing.
Rated 12Vdc, 0.35A, 16.3
CFM. Outward airflow
orientation. Secured to the
front Chassis by screws. Fan
leads provided with min. 0.4mm
thick tubing.
Rated 12Vdc, 0.31A, 14.8
GPWV2
UL
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 41 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Fan (Alternate)
MINEBEA MOTOR
MFG CORP
Fan (Alternate)
MINEBEA MOTOR
MFG CORP
Fan (Alternate)
MINEBEA MOTOR
MFG CORP
Fan (Alternate)
Delta Electronics Inc
Insulating
Various
Tubing/Sleeving (Applied
on leads of thermal
switch on L100 except
secondary portion and
TRF No. IECEN60950_1C
Verdict
CFM. Outward airflow
orientation. Secured to the
front Chassis by screws. Fan
leads provided with min. 0.4mm
thick tubing.
1611RL-04W-B50 Rated 12Vdc, 0.22A, 10.5
CFM. Outward airflow
orientation. Secured to the
front Chassis by screws. Fan
leads provided with min. 0.4mm
thick tubing.
1611RL-04W-B60 Rated 12Vdc, 0.35A, 13.7
CFM. Outward airflow
orientation. Secured to the
front Chassis by screws. Fan
leads provided with min. 0.4mm
thick tubing.
1611RL-04W-B70 Rated 12Vdc, 0.47A, 15.8
CFM. Outward airflow
orientation. Secured to the
front Chassis by screws. Fan
leads provided with min. 0.4mm
thick tubing.
FFB0412VHN
Rated 12Vdc, 0.16A, 15.79
CFM. Outward airflow
orientation. Secured to the
front Chassis by screws. Fan
leads provided with min. 0.4mm
thick tubing.
Varous
FEP, PTFE, PVC, TFE,
neoprene, or marked VW-1;
minimum 105 degree C,
minimum 300 V. Mininum 0.4
mm thick
Underwriters Laboratories Inc.
GPWV2
UL
GPWV2
UL
GPWV2
UL
GPWV2
UL
UZFT2, YDPU2,
YDTU2
UL
Issue Date:
2010-05-19
Page 42 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
fan leads)
Insulating
Various
Tubing/Sleeving (Applied
on other components)
Varous
Verdict
FEP, PTFE, PVC, TFE,
neoprene, or marked VW-1;
minimum 105 degree C,
minimum 300 V.
Min. 300V, min. 80 degree C.
VW-1
Min. 60V, min. 80 degree C.
VW-1
300 V ac, 20 A, 120 degree C.
Rated minimum V-1, minimum
105 degree C.
UZFT2, YDPU2,
YDTU2
UL
AVLV2, AVLV8
UL
AVLV2, AVLV8
UL
XCFR2
ZPMV2
UL
UL
ZPMV2
UL
JDYX, JDYX7
JDYX2, JDYX8
UL
UL
Internal Wiring (Primary,
for thermal switches)
Internal Wiring (SELV,
for fan leads)
Terminal Block (TB1)
Printed Wiring Boards
(Main board and Small
secondary board)
Control Board (optional)
Various
Various
Various
Various
Switchlab
Various
T35 series
Various
Various
Various
Fuse (FS1)
Fuse (FS1) (Alternate)
Various
CONQUER
ELECTRONICS CO
LTD
LITTELFUSE INC
BEL FUSE INC
Various
UBM
Rated minimum V-1, minimum
105 degree C.
F8A, 250Vac
F8A, 250Vac
216
5HF
F8A, 250Vac
F8A, 250Vac
JDYX2, JDYX8
JDYX2, JDYX8
UL
UL
WALTER
ELECTRONIC CO
LTD
Various
FSC
F8A, 250Vac
JDYX2, JDYX8
UL
Various
ARCOTRONICS
SPA
R.46, R.49
EPCOS
ELECTRONIC
B3292 series
Rated max. 470 k ohms,
-minimum 1/4 W.
Each rated max. 1 uF,
FOWX2
minimum 250 Vac, 110 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
FOWX2
minimum 250 Vac, 105 degree
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Fuse (FS1) (Alternate)
Bleeder Resistors (R1,
R2)
X-Capacitors (C1, C2)
(Optional)
X-Capacitors (C1, C2)
(Optional) (Alternate)
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
-UL
UL
Issue Date:
2010-05-19
Page 43 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
COMPONENTS S A
X-Capacitors (C1, C2)
(Optional) (Alternate)
ISKRA
KNB1530
KONDENZATORJI D
D
X-Capacitors (C1, C2)
(Optional) (Alternate)
ISKRA
KNB1560
KONDENZATORJI D
D
X-Capacitors (C1, C2)
(Optional) (Alternate)
LIOW GU
ELECTRONICS
INDUSTRY CO LTD
GS-L
X-Capacitors (C1, C2)
(Optional) (Alternate)
PILKOR
ELECTRONICS CO
LTD
PCX2 335
X-Capacitors (C1, C2)
(Optional) (Alternate)
PILKOR
ELECTRONICS CO
LTD
PCX2 335M
X-Capacitors (C1, C2)
(Optional) (Alternate)
PILKOR
ELECTRONICS CO
LTD
PCX2 337
X-Capacitors (C1, C2)
ULTRA TECH XIPHI
HQX
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 100 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 125 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 100 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 85 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 105 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 100 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
FOWX2
UL
FOWX2
UL
FOWX2
UL
FOWX2
UL
FOWX2
UL
FOWX2
UL
FOWX2
UL
Issue Date:
2010-05-19
Page 44 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
(Optional) (Alternate)
ENTERPRISE CO
LTD
X-Capacitors (C1, C2)
(Optional) (Alternate)
VISHAY
CAPACITORS
BELGIUM N V
339
X-Capacitors (C1, C2)
(Optional) (Alternate)
CHENG TUNG
INDUSTRIAL CO
LTD
CTX
X-Capacitors (C1, C2)
(Optional) (Alternate)
SHINY SPACE
ENTERPRISE CO
LTD
SX1
Y-Capacitors (C3, C4,
C23, C24, C30)
(Optional)
MURATA MFG CO
LTD
KX, KH
Y-Capacitors (C3, C4,
C23, C24, C30)
(Optional) (Alternate)
WALSIN
TECHNOLOGY
CORP
AH, AC
Y-Capacitors (C3, C4,
C23, C24, C30)
(Optional) (Alternate)
TDK-EPC CORP
CD, CS
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
minimum 250 Vac, 100 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 105 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 100 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 1 uF,
minimum 250 Vac, 100 degree
C. Class X1 or X2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 4700 pF,
minimum 250 Vac, 125 degree
C. Class Y1 or Y2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 4700 pF,
minimum 250 Vac, 125 degree
C. Class Y1 or Y2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
Each rated max. 4700 pF,
minimum 250 Vac, 125 degree
C. Class Y1 or Y2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
FOWX2
UL
FOWX2
UL
FOWX2
UL
FOWX2, FOWX8
UL
FOWX2, FOWX8
UL
FOWX2, FOWX8
UL
Issue Date:
2010-05-19
Page 45 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Y-Capacitors (C3, C4,
C23, C24, C30)
(Optional) (Alternate)
WELSON
INDUSTRIAL CO
LTD
WD, KL
Varistor (ZNR1)
(Optional)
THINKING
ELECTRONIC
INDUSTRIAL CO
LTD
JOYIN CO LTD
TVR10471-D,
TVR14471-D
Varistor (ZNR1)
(Optional) (Alternate)
Varistor (ZNR1)
(Optional) (Alternate)
Varistor (ZNR1)
(Optional) (Alternate)
Thermistor (RTH1)
(Optional)
Relay (RY1)
Relay (RY1) (Alternate)
Relay (RY1) (Alternate)
Rectifier (BD1)
Electrolytic Capacitor
(C5)
CENTRA SCIENCE
CORP
NIPPON CHEMICON CORP
Various
Each rated max. 4700 pF,
FOWX2, FOWX8
minimum 250 Vac, 125 degree
C. Class Y1 or Y2. (Meet IEC
60384-14). The damp heat test
duration in 21 days minimum.
300Vac
VZCA2
UL
14S471K,
14N471K
CNR-14D471K
300Vac
VZCA2
UL
300Vac
VZCA2
UL
TNR14V-471K
300Vac
VZCA2
UL
Various
Rated minimum 2 A, maximum
20 ohms at 25 degree C
Rated 10 A, 277Vac.
--
--
NRNT2
UL
OJESS112HMF,
OJESH112HMF
Rated 10A, 250V.
NRNT2
UL
OJESS112LMH,
OJESH112LMH
Rated 8A, 250V.
NRNT2
UL
Various
Rated minimum 2A, minimum
QQQX2
600 V, minimum 100 degree C,
minimum isolation voltage 1500
Vac
Integral pressure relief, rated
-330 uF, minimum 400 V,
minimum 85 degree C.
UL
SONG CHUAN
PRECISION CO LTD
TYCO
ELECTRONICS
(SHENZHEN) CO.
LTD
TYCO
ELECTRONICS
(SHENZHEN) CO.
LTD
Various
835-1A -B-C
Various
Various
TRF No. IECEN60950_1C
Verdict
Underwriters Laboratories Inc.
UL
--
Issue Date:
2010-05-19
Page 46 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Transistors (Q1, Q2, Q3, Various
Q4)
Line Filters (LF1, LF2)
Various
(Optional)
Core (LF1, LF2)
Various
Various
Coil (LF1, LF2)
PFC choke (L3)
Various
Various
Various
TR-934
Core (L3)
Various
Various
Coil (L3)
Choke (T2) (Optional)
Various
Various
Various
TR-435
Choke (T2) (Optional)
(Alternate)
Core (T2)
Various
TR-852
Various
Various
Coil (T2)
Triple Insulated Winding
Wire (T2)
Optical Isolators (U2, U3,
U4, U901) (U4 optional;
U901 on optional Control
Board)
Optical Isolators (U2, U3,
U4, U901) (U4 optional;
U901 on optional Control
Board)
Optical Isolators (U2, U3,
Various
Various
Various
Various
Sharp Corp.,
Electronic
Components Group
Verdict
Rated 12A-22 A, minimum 500
V.
Open type construction. Rated
130 degree C.
Ferrite, measured overall 22
mm OD by 14 mm ID by 8 mm
wide.
Rated minimum 130 degree C.
Open type construction. Rated
130 degree C.
Ferrite, measured overall 26.92
mm OD by 14.73 mm ID by 18
mm wide.
Rated minimum 130 degree C.
Open type construction. Rated
130 degree C.
Open type construction. Rated
130 degree C.
Ferrite, measured overall 13
mm OD by 7 mm ID by 5 mm
wide.
Rated minimum 130 degree C.
Rated minimum 130 degree C.
--
--
--
--
--
--
OBMW2
--
UL
--
--
--
OBMW2
--
UL
--
7-09
--
--
7-10
--
--
OBMW2
OBJT2
UL
UL
PC123
Minimum 5000Vac isolation.
Double protection.
FPQU2
UL
Lite-On Technology
Corp.
LTV-817
Minimum 5000Vac isolation.
Double protection.
FPQU2
UL
COSMO
K1010
Minimum 5000Vac isolation.
FPQU2
UL
TRF No. IECEN60950_1C
TR-548
Various
Underwriters Laboratories Inc.
7-07
7-08
Issue Date:
2010-05-19
Page 47 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
U4, U901) (U4 optional;
U901 on optional Control
Board)
Bridging Capacitor (C31)
(Optional)
Result - Remark
ELECTRONICS
CORP
MURATA MFG CO
LTD
Double protection.
KX
Bridging Capacitor (C31) WALSIN
(Optional) (Alternate)
TECHNOLOGY
CORP
AH
Briding Capacitor (C31)
(Optional) (Alternate)
CD
TDK-EPC CORP
Bridging Capacitor (C31) WELSON
(Optional) (Alternate)
INDUSTRIAL CO
LTD
WD
Transformer (T1)
TF-2107 (for
Y=3.3), TF-2108
(for Y=5), TF 2109 (for Y=7.5),
TF-2110 (for
Y=12), TF-2111
(for Y=15), TF2112 (for Y=24),
TF-2113 (for
Y=36), TF-2114
(for Y=48)
Jet Signal Industries
Co., Ltd.
TRF No. IECEN60950_1C
Verdict
Underwriters Laboratories Inc.
Rated max. 2200 pF, minimum
250 Vac, 125 degree C. Class
Y1. (Meet IEC 60384-14). The
damp heat test duration in 21
days minimum.
Rated max. 2200 pF, minimum
250 Vac, 125 degree C. Class
Y1. (Meet IEC 60384-14). The
damp heat test duration in 21
days minimum.
Rated max. 2200 pF, minimum
250 Vac, 125 degree C. Class
Y1. (Meet IEC 60384-14). The
damp heat test duration in 21
days minimum.
Rated max. 2200 pF, minimum
250 Vac, 125 degree C. Class
Y1. (Meet IEC 60384-14). The
damp heat test duration in 21
days minimum.
Class B (130 degree C)
Insulation System, Type
SBI4.2.
FOWX2
UL
FOWX2
UL
FOWX2
UL
FOWX2
UL
OBJY2
UL
7-01
Issue Date:
2010-05-19
Page 48 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Transformer (T1)
(Alternate)
Elytone Electronic
Co., Ltd.
Transformer (T1)
(Alternate)
Long Sail Electronic
Co., Ltd.
Core (T1)
Various
TF-2107 (for
Y=3.3), TF-2108
(for Y=5), TF 2109 (for Y=7.5),
TF-2110 (for
Y=12), TF-2111
(for Y=15), TF2112 (for Y=24),
TF-2113 (for
Y=36), TF-2114
(for Y=48)
TF-2107 (for
Y=3.3), TF-2108
(for Y=5), TF 2109 (for Y=7.5),
TF-2110 (for
Y=12), TF-2111
(for Y=15), TF2112 (for Y=24),
TF-2113 (for
Y=36), TF-2114
(for Y=48)
Various
Coil (T1)
Primary Copper foil (T1)
Various
Various
Various
Various
Bobbin (T1)
Sumitomo Bakelite
Co Ltd.
PM-9820
Bobbin (T1) (Alternate)
Sumitomo Bakelite
PM-9630
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
Class B (130 degree C)
Insulation System, Type
SBI4.2.
OBJY2
UL
7-02
Class B (130 degree C)
Insulation System, Type
SBI4.2.
OBJY2
UL
7-03
Ferrite, overall 45 by 39 by 13
mm.
Rated minimum 130 degree C.
Measured overall 20 mm by
0.025 mm thick. Provided with
insulation tape minimum 3.0
mm from both edge of copper
foil.
Phenolic, rated V-0, 150
degree
C, minimum 0.71 mm thick.
Phenolic, rated V-0, 150
--
--
OBMW2
--
UL
--
QMFZ2
UL
QMFZ2
UL
Issue Date:
2010-05-19
Page 49 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
Co Ltd.
Insulating Tape (T1)
Insulating Tape (T1)
(Alternate)
Insulating Tape (T1)
(Alternate)
Varnish (T1)
Varnish (T1) (Alternate)
Varnish (T1) (Alternate)
Varnish (T1) (Alternate)
Varnish (T1) (Alternate)
Tubing (T1)
Tubing (T1) (Alternate)
Margin Tape (T1)
Margin Tape (T1)
(Alternate)
Margin Tape (T1)
(Alternate)
degree
C, minimum 0.71 mm thick.
3M Co.
1350F-1, 1350T-1 Polyester tape, rated 130
degree C.
Symbio Inc.
35660Y, 35660
Polyester tape, rated 130
degree C.
Bondtec Pacific Co., 370S
Polyester tape, rated 130
Ltd.
degree C.
John C Dolph Co.
BC-346A
Rated minimum 130 degree C.
Hitachi Chemical Co., WP-2952F-2G
Rated minimum 130 degree C.
Ltd.
Elantas Electrical
468-2(x)
Rated minimum 130 degree C.
Insulation Elantas
Pdg Inc (Ripley Resin
Engineering Co., Inc.)
KYOCERA
TVB-2180T++
Rated minimum 130 degree C.
CHEMICAL CORP
PD
V1630FS
Rated minimum 130 degree C.
GEORGE/VIKING
Great Holding
TFL, TFT
Rated minimum 200 degree C.
Industrial Co., Ltd.
Provided on all exit leads.
Zeus Industrial
TFE-TW-300,
Rated minimum 200 degree C.
Products Inc.
TFE-LW-150
Provided on all exit leads.
3M Co.
44D-A, 44T-A
Polyester tape, rated 130
degree C, measured min. 3.0
mm width on both side of
bobbin.
Symbio Inc.
35661, 35660,
Polyester tape, rated 130
35660Y
degree C, measured min. 3.0
mm width on both side of
bobbin.
Bondtec Pacific Co., 201
Polyester tape, rated 130
Ltd.
degree C, measured min. 3.0
mm width on both side of
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
OANZ2
UL
OANZ2
UL
OANZ2
UL
OBOR2
OBOR2
UL
UL
OBOR2
UL
OBOR2
UL
OBOR2
UL
YDPU2
UL
YDPU2
UL
OANZ2
UL
OANZ2
UL
OANZ2
UL
Issue Date:
2010-05-19
Page 50 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Transformer (T900)
(Provided when Optional
Control Board is
provided)
Transformer (T900)
(Provided when Optional
Control Board is
provided) (Alternate)
Transformer (T900)
(Provided when Optional
Control Board is
provided) (Alternate)
Core (T900)
Long Sail Electronic
Co., Ltd.
TF-1593
Jet Signal Industries
Co., Ltd.
TF-1593
Elytone Electronic
Co., Ltd.
TF-1593
Various
Various
Bobbin (T900)
Sumitomo Bakelite
Co., Ltd.
Bobbin (T900)
(Alternate)
Coils (T900)
Primary copper foil
(T900)
Insulating Tape (T900)
Sumitomo Bakelite
Co., Ltd.
Various
Various
Insulating Tape (T900)
(Alternate)
Insulating Tape (T900)
(Alternate)
Margin Tape (T900)
Symbio Inc.
Margin Tape (T900)
Symbio Inc.
3M Co.
Bondtec Pacific Co.,
Ltd.
3M Co.
TRF No. IECEN60950_1C
Verdict
bobbin.
Class B (130 degree C)
Insulation System, Type
SBI4.2.
OBJY2
UL
7-06
Class B (130 degree C)
Insulation System, Type
SBI4.2.
OBJY2
UL
7-04
Class B (130 degree C)
Insulation System, Type
SBI4.2.
OBJY2
UL
7-05
--
--
QMFZ2
UL
QMFZ2
UL
OBMW2
--
UL
--
OANZ2
UL
OANZ2
UL
OANZ2
UL
OANZ2
UL
OANZ2
UL
Ferrite, measured overall 15 by
15 by 4.65 mm.
PM-9820
Phenolic. Rated V-0, 150
degree C, minimum 0.71 mm
thick.
PM-9630
Phenolic. Rated V-0, 150°C,
minimum 0.71 mm thick.
Various
Rated minimum 130 degree C.
Various
Measured overall 8 mm by
0.025 mm thick.
1350F-1, 1350T-1 Polyester tape, rated 130
degree C.
35660, 35660Y
Polyester tape, rated 130
degree C.
370S
Polyester tape, rated 130
degree C.
44D-A, 44T-A
Polyester tape, rated 130
degree C, measured min. 3.3
mm width on both side of
bobbin.
35661
Polyester tape, rated 130
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 51 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
(Alternate)
Margin Tape (T900)
(Alternate)
Bondtec Pacific Co.,
Ltd.
201
Varnish (T900)
Varnish (T900)
(Alternate)
Varnish (T900)
(Alternate)
John C Dolph Co.
Hitachi Chemical Co.,
Ltd.
Elantas Electrical
Insulation Elantas
PDG Inc.
Kyocera Chemical
Corp.
PD George / Vinking
BC-346A
WP-2952F-2G
Verdict
degree C, measured min. 3.3
mm width on both side of
bobbin.
Polyester tape, rated 130
degree C, measured min. 3.3
mm width on both side of
bobbin.
Rated minimum 130 degree C.
Rated minimum 130 degree C.
OANZ2
UL
OBOR2
OBOR2
UL
UL
468-2-7, 468-2,
486-2FC
Rated minimum 130 degree C.
OBOR2
UL
TVB-2180T
Rated minimum 130 degree C.
OBOR2
UL
V1630FS
Rated minimum 130°C.
OBOR2
UL
Great Holding
Industrial Co., Ltd.
Zeus Industrial
Products Inc.
Seki Controls Co.,
Ltd.
TFL, TFT
YDPU2
UL
YDPU2
UL
XAPX2
UL
Leads of Thermal
Switches
Various
Various
AVLV2
UL
Heat Sink (HS1)
Various
Various
Rated minimum 200 degree C.
Provided on all exit leads.
Rated minimum 200 degree C.
Provided on all exit leads.
Two provided. Rated 125/250
Vac, 70-130 degree C.
Provided with lead wires and
connected to connectors TSW1
and TSW2. One secured on
L100 choke and the other one
secured on HS1 above Q1 and
Q2 via a Heat Sink by a screw.
Minimum 300 V, PVC
insulated, minimum 0.2 mm
thick minimum 22 AWG, 125
deg C, marked with VW-1.
Copper, minimum 1.5 mm
Varnish (T900)
(Alternate)
Varnish (T900)
(Alternate)
Tubing (T900)
Tubing (T900)
(Alternate)
Thermal Switches
TRF No. IECEN60950_1C
TFE-TW-300,
TFE-LW-150
ST-22
Underwriters Laboratories Inc.
--
--
4-02
Issue Date:
2010-05-19
Page 52 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Considered earthed
Heat Sink (HS2)
Considered earthed
Various
Various
Heat Sink (HS3)
Considered secondary
Various
Various
Heat Sink (HS4)
Considered earthed
Various
Various
Heat Sink (for Thermal
Switch)
Various
Various
Insulation Sheets
(Provided between
PWBs traces and bottom
Chassis)
Insulation Sheets
(Provided between
PWBs traces and bottom
Chassis) (Alternate)
Insulation Sheets
(Provided on Top
chassis above C5 and
L3)
Insulation Sheets
(Provided on Top
chassis above C5 and
L3) (Alternate)
Insulation Sheets
(Provided on Top
chassis near L100)
Formex,Div of
ILLIONIS TOOL
WORKS INC
Formex GK
Sabic Innovative
Plastics
FR700
Formex,Div of
ILLIONIS TOOL
WORKS INC
Formex GK
Sabic Innovative
Plastics
FR700
Formex,Div of
ILLIONIS TOOL
WORKS INC
Formex GK
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
thick. See Enclosure for
detailed dimensions.
Aluminum, minimum 1.5 mm
thick. See Enclosure for
detailed dimensions.
Copper, minimum 1.0 mm
thick. See Enclosure for
detailed dimensions.
Copper, minimum 1.5 mm
thick. See Enclosure for
detailed dimensions.
Aluminum, minimum 1.5mm
thick. See enclosure for
detailed dimensions
Mylar, minimum V-2, minimum
105 degree C, minimum 0.2
mm thick. See Enclosure for
detailed dimensions.
Mylar, minimum V-2, minimum
105 degree C, minimum 0.2
mm thick. See Enclosure for
detailed dimensions.
Mylar, minimum V-2, minimum
105 degree C, minimum 0.2
mm thick. See Enclosure for
detailed dimensions.
Mylar, minimum V-2, minimum
105 degree C, minimum 0.2
mm thick. See Enclosure for
detailed dimensions.
Mylar, minimum V-2, minimum
105 degree C, minimum 0.2
mm thick. See Enclosure for
detailed dimensions.
--
--
4-03
--
--
4-04
--
--
4-05
--
--
4-10
QMFZ2
UL
4-13
QMFZ2
UL
QMFZ2
UL
QMFZ2
UL
QMFZ2
UL
4-12
4-11
Issue Date:
2010-05-19
Page 53 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Insulation Sheets
(Provided on Top
chassis near L100)
(Alternate)
Silicone Rubber
Insulators (Provided for
Q1, Q2, Q3, Q4, D1)
Silicone Rubber
Insulators (Provided for
Q1, Q2, Q3, Q4, D1)
(Alternate)
Adhesive Glue (Provided
for C10, T2, Thermal
Switches, fly lead FL1A
of T900)
Label
Result - Remark
Sabic Innovative
Plastics
FR700
SIX PHASE CO LTD
610
PIONEER
MATERIAL
PRECISION TECH
PMP-P-400,
PMP-P-100
Various
Various
TRF No. IECEN60950_1C
Verdict
Mylar, minimum V-2, minimum
105 degree C, minimum 0.2
mm thick. See Enclosure for
detailed dimensions.
Minimum V-2, minimum 105
degree C, minimum 0.2 mm
thick.
Minimum V-2, minimum 150
degree C, minimum 0.2 mm
thick.
QMFZ2
UL
QMFZ2
UL
QMFZ2
UL
Various
Rated minimum V-2, min. 105
degree C
QMFZ2
UL
Various
Rated minimum 70 degree C.
PGDQ2
UL
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 54 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
1.6.2
TABLE: electrical data (in normal conditions)
U (V)
Model
HRPG450-5
90
100
240
254
264
90
100
240
254
264
Model
HRPG450-12
90
100
240
254
264
90
100
240
254
264
Model
HRPG450-24
90
100
240
254
264
90
100
240
254
264
Model
HRPG450-48
90
100
240
I (A)
Result - Remark
I rated (A)
P (W)
Fuse #
Verdict
Pass
I fuse (A)
condition/status
--
--
--
--
--
--
6.36
5.64
2.29
2.17
2.09
6.37
5.67
2.30
2.18
2.10
--
-6.0
6.0
---6.0
6.0
----
567
562
539
539
539
570
565
540
539
539
--
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
--
6.36
5.64
2.29
2.17
2.09
6.37
5.67
2.30
2.18
2.10
--
+5V/90A / 50Hz
+5V/90A / 50Hz
+5V/90A / 50Hz
+5V/90A / 50Hz
+5V/90A / 50Hz
+5V/90A / 60Hz
+5V/90A / 60Hz
+5V/90A / 60Hz
+5V/90A / 60Hz
+5V/90A / 60Hz
--
6.06
5.38
2.19
2.08
2.01
6.07
5.40
2.20
2.09
2.02
--
-6.0
6.0
---6.0
6.0
----
543
537
515
515
514
543
538
516
515
514
--
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
--
6.06
5.38
2.19
2.08
2.01
6.07
5.40
2.20
2.09
2.02
--
+12V/37.5A/ 50Hz
+12V/37.5A/ 50Hz
+12V/37.5A/ 50Hz
+12V/37.5A/ 50Hz
+12V/37.5A/ 50Hz
+12V/37.5A/ 60Hz
+12V/37.5A/ 60Hz
+12V/37.5A/ 60Hz
+12V/37.5A/ 60Hz
+12V/37.5A/ 60Hz
--
6.02
5.34
2.18
2.06
1.99
6.03
5.35
2.18
2.07
2.00
--
-6.0
6.0
---6.0
6.0
----
539
532
510
510
510
540
533
511
511
510
--
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
FS1
--
6.02
5.34
2.18
2.06
1.99
6.03
5.35
2.18
2.07
2.00
--
+24V/18.8A/ 50Hz
+24V/18.8A/ 50Hz
+24V/18.8A/ 50Hz
+24V/18.8A/ 50Hz
+24V/18.8A/ 50Hz
+24V/18.8A / 60Hz
+24V/18.8A / 60Hz
+24V/18.8A / 60Hz
+24V/18.8A / 60Hz
+24V/18.8A / 60Hz
--
6.00
5.32
2.16
-6.0
6.0
536
529
507
FS1
FS1
FS1
6.00
5.32
2.16
+48V/9.5A/ 50Hz
+48V/9.5A/ 50Hz
+48V/9.5A/ 50Hz
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 55 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
254
264
90
100
240
254
264
Requirement + Test
2.05
1.97
6.01
5.33
2.17
2.06
1.99
Result - Remark
---6.0
6.0
---
507
507
536
530
507
508
507
FS1
FS1
FS1
FS1
FS1
FS1
FS1
2.05
1.97
6.01
5.33
2.17
2.06
1.99
Verdict
+48V/9.5A/ 50Hz
+48V/9.5A/ 50Hz
+48V/9.5A / 60Hz
+48V/9.5A / 60Hz
+48V/9.5A / 60Hz
+48V/9.5A / 60Hz
+48V/9.5A / 60Hz
supplementary information:
Maximum Normal load: Loaded to output rating.
2.10.3 and
2.10.4
TABLE: clearance and creepage distance measurements
Clearance (cl) and creepage
distance (cr) at/of/between:
U peak
(V)
U r.m.s.
(V)
Required cl
(mm)
Pass
cl
(mm)
Required cr
(mm)
cr
(mm)
(Measured on Main PWB)
Line to Neutral before Fuse
FS1 (FI)
Under Fuse FS1 (BI)
L and N trace to FG trace (RI)
Between C31 Pri. to Sec Trace
(RI)
Under T1 (RI)
-<420
-<250
-2.0
-2.7
-2.5
-2.7
<420
<420
<420
<250
<250
<250
2.0
4.0
4.0
7.4
5.0
6
2.5
5.0
5.0
7.4
5.0
8
480
<250
4.2
6
5.0
Under optical Isolator (U2, U3,
U4) (RI)
<420
<250
4.0
7.6
5.0
Optical Isolator Body (U2, U3,
U4)
(Measured on Control PWB)Under optical U901
Under T900
(Measured on product)
C5 to Top Chassis (BI)
<420
<250
4.0
6.6
5.0
6 (with
PWB slots
bypassed)
7.6 (with
PWB slots
bypassed)
6.6
-<420
456
-<420
-<250
303
-<250
-4.0
4.2
-2.0
-7.3
5.5
-2.5
-5.0
6.2
-2.5
(Measured on T1)
--
--
--
--
--
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
-7.3
7.2
-N/A (no
creepage
path)
Core is
considered
floating,
maintains
BI to
primary
and SI to
secondary.
Core is
Issue Date:
2010-05-19
Page 56 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
Primary winding to secondary
winding (RI)
480
<250
4.2
6
5.0
Primary winding to secondary
terminals (RI)
480
<250
4.2
5.5
5.0
Secondary winding to primary
terminal (RI)
480
<250
4.2
6.0
5.0
Secondary winding to core (SI)
480
<250
2.1
3.0
2.5
Secondary terminal to core (SI) 480
<250
2.1
8.6
2.5
Primary winding to core (BI)
480
<250
2.1
3.0
2.5
Primary terminal to core (BI)
480
<250
2.1
8.6
2.5
(Measured on T900)
--
--
--
--
--
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
wrapped
with two
layers of
Insulation
Tape
6.0 (3.0mm
margin
tape is
provided on
both sides
of each
winding)
5.5
(measured
min. 2.5mm
from
terminal pin
to inner
edge of
bobbin)
6.0
(measured
min. 3.0mm
from
terminal pin
to inner
edge of
bobbin)
3.0 (margin
tape)
8.6
(measured
on bobbin)
3.0 (margin
tape)
8.6
(measured
on bobbin)
Core is
considered
floating,
maintains
BI to
primary
and SI to
secondary.
Core is
wrapped
with
Issue Date:
2010-05-19
Page 57 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
Primary winding to secondary
winding (RI)
456
303
4.2
6.6
6.2
Primary winding to secondary
terminals (RI)
456
303
4.2
6.7
6.2
Secondary winding to primary
terminal (RI)
456
303
4.2
6.7
6.2
Secondary winding to core (SI)
456
303
2.1
3.3
3.1
Secondary terminal to core (SI) 456
303
2.1
6.7
3.1
Primary winding to core (BI)
456
303
2.1
3.3
3.1
Primary terminal to core (BI)
456
303
2.1
6.7
3.1
insulated
tape.
6.6
(primary
margin
tape +
secondary
margin
tape)
6.7 (bend
around
tape + 1.2
along
bobbin
surface)
6.7 (bend
around
tape + 1.2
along
bobbin
surface)
3.3 (margin
tape)
6.7 (bobbin
bottom
terminals
board)
3.3 (margin
tape)
6.7 (bobbin
bottom
terminal
board)
supplementary information:
1) The following wiring is sleeved with tubing minimum 0.4 mm thick: DC fan leads, leads of thermal switch on
L100 (except the portion on primary side) 2) The following components are sleeved: RTH1, D1, R4, R5, Q1,
Q2, Q3, Q4 3) The following components were tested with 10N: T2, C31, C18, C5, L3 4) Slots are provided on
both Main board and control board. See Enclosure PWBs layouts for details. 5) The following components are
secured with adhesive: C10, T2, Thermal Switches, fly lead FL1A of T900. 6) Transformer (T900) core is
entirely wrapped by two layers of insulation tape.
2.10.5
TABLE: distance through insulation measurements
Distance through insulation (DTI) at/of:
--
TRF No. IECEN60950_1C
U peak
(V)
--
Urms
(V)
--
Underwriters Laboratories Inc.
Pass
Test voltage Required DTI
(V)
(mm)
--
--
DTI
(mm)
--
Issue Date:
2010-05-19
Page 58 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
supplementary information:
See Critical Component List
4.3.8
TABLE: Batteries
N/A
The tests of 4.3.8 are applicable only when appropriate
battery data is not available.
Is it possible to install the battery in a reverse polarity
position?
Non-rechargeable batteries
Discharging
Meas.
current
Rechargeable batteries
Unintentional
charging
Manuf.
specs.
Charging
Meas. current
Discharging
Manuf.
specs.
Meas.
current
Manuf.
specs.
Reversed
charging
Meas.
current
Manuf.
specs.
Max.
current
during
normal
operation
Max.
current
during fault
operation
Test results:
Verdict
- Chemical leaks
- Explosion of the battery
- Emission of flame or expulsion of molten metal
- Electric strength tests of equipment after completion of tests
supplementary information:
4.5
TABLE: Thermal requirements
Supply voltage (V) ..................................... :
TRF No. IECEN60950_1C
Pass
See
below
See
below
Underwriters Laboratories Inc.
See
below
See
below
--
—
Issue Date:
2010-05-19
Page 59 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Ambient Tmin (°C) ..................................... :
Ambient Tmax (°C) .................................... :
See
below
See
below
See
below
See
below
Maximum measured temperature T of part/at:
See
below
See
below
--
—
--
—
T (°C)
Model HRPG-450-5
90V /
60Hz
TB1 body
C24 body ( Y-cap.)
C1 body ( X-cap.)
ZNR1 body
LF1 coil
C2 body ( X-cap.)
LF2 coil
C3 body ( Y-cap.)
RY1 body
PCB under RTH1
C30 body ( Y-cap.)
HS near Q1
L3 coil
C5 body (Bulk cap.)
T2 coil
HS near Q3
T1 Primary coil
T1 secondary coil
T1 Core
C31 body (Bridging-cap.)
U4 body (photocouple)
L100 coil
T900 top-side coil
T900 bottom-side coil
T900 core
U901 body (photocouple)
Metal ecclosure
Ambient air
Test time (h:m)
Model HRPG-450-12
31.2
37.4
44.2
64.9
46.7
56.9
76.4
48.5
60.4
77.0
57.6
71.1
85.0
53.3
48.8
55.8
73.6
85.3
62.0
56.0
57.4
59.3
33.7
33.7
33.0
32.9
47.8
30.7
-90V /
60Hz
TRF No. IECEN60950_1C
See
below
See
below
Verdict
90V /
60Hz
normali
zed to
50
degree
C
ambien
t
50.5
56.7
63.5
84.2
66.0
76.2
95.7
67.8
79.7
96.3
76.9
90.4
104.3
72.6
68.1
75.1
92.9
104.6
81.3
75.3
76.7
78.6
53.0
53.0
52.3
52.2
67.1
50.0
1:24
90V /
60Hz
Underwriters Laboratories Inc.
264V /
60Hz
29.5
34.0
40.1
44.0
42.0
46.3
54.2
40.2
48.7
60.8
46.5
56.0
59.2
48.4
45.6
50.6
69.9
80.6
58.2
53.3
55.5
57.8
33.0
32.7
32.4
32.2
42.6
26.6
-264V /
60Hz
allowed
Tmax
(°C)
264V /
60Hz
normali
zed to
50
degree
C
ambien
t
52.9
57.4
63.5
67.4
65.4
69.7
77.6
63.6
72.1
84.2
69.9
79.4
82.6
71.8
69.0
74.0
93.3
104.0
81.6
76.7
78.9
81.2
56.4
56.1
55.8
55.6
66.0
50.0
1:13
264V /
60Hz
-
-
-
120
85
85
85
130
85
130
125
105
105
125
105
130
85
130
105
110
110
110
125
100
105
110
110
110
100
70
---
Issue Date:
2010-05-19
Page 60 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
ZNR1 body
C2 body ( X-cap.)
LF2 coil
PCB under RTH1
C30 body ( Y-cap.)
HS near Q1
L3 coil
T1 Primary coil
T1 secondary coil
T1 Core
C31 body (Bridging-cap.)
T900 top-side coil
T900 bottom-side coil
T900 core
Metal ecclosure
Ambient air
Test time (h:m)
Model HRPG-450-24
38.6
45.2
57.3
50.8
53.1
57.8
58.2
52.7
55.2
51.6
37.1
29.8
29.1
28.9
40.7
26.0
-90V /
60Hz
ZNR1 body
C2 body ( X-cap.)
LF2 coil
PCB under RTH1
C30 body ( Y-cap.)
HS near Q1
L3 coil
T1 Primary coil
T1 secondary coil
T1 Core
C31 body (Bridging-cap.)
T900 top-side coil
T900 bottom-side coil
T900 core
Metal ecclosure
53.7
44.9
48.5
42.0
55.0
45.8
45.2
51.1
58.0
47.1
32.4
28.0
27.9
28.2
35.1
TRF No. IECEN60950_1C
normali
zed to
50
degree
C
ambien
t
62.6
69.2
81.3
74.8
77.1
81.8
82.2
76.7
79.2
75.6
61.1
53.8
53.1
52.9
64.7
50.0
1:12
90V /
60Hz
normali
zed to
50
degree
C
ambien
t
79.3
70.5
74.1
67.6
80.6
71.4
70.8
76.7
83.6
72.7
58.0
53.6
53.5
53.8
60.7
Underwriters Laboratories Inc.
33.3
34.5
36.8
37.7
38.3
41.2
41.9
48.4
50.6
45.8
34.3
27.9
27.4
27.1
33.8
25.1
-264V /
60Hz
50.9
37.5
37.5
34.9
48.6
40.3
39.2
49.8
56.3
45.5
32.4
28.2
28.0
28.4
33.2
Verdict
normali
zed to
50
degree
C
ambien
t
58.2
59.4
61.7
62.6
63.2
66.1
66.8
73.3
75.5
70.7
59.2
52.8
52.3
52.0
58.7
50.0
1:28
264V /
60Hz
normali
zed to
50
degree
C
ambien
t
76.3
62.9
62.9
60.3
74.0
65.7
64.6
75.2
81.7
70.9
57.8
53.6
53.4
53.8
58.6
-
85
85
130
105
125
105
130
110
110
110
125
110
110
110
70
---
-
85
85
130
105
125
105
130
110
110
110
125
110
110
110
70
Issue Date:
2010-05-19
Page 61 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Ambient air
Test time (h:m)
Model HRPG-450-48
24.4
-90V /
60Hz
ZNR1 body
C2 body ( X-cap.)
LF2 coil
PCB under RTH1
C30 body ( Y-cap.)
HS near Q1
L3 coil
T1 Primary coil
T1 secondary coil
T1 Core
C31 body (Bridging-cap.)
T900 top-side coil
T900 bottom-side coil
T900 core
Metal ecclosure
Ambient air
Test time (h:m)
38.9
41.9
52.3
53.0
52.7
52.2
53.3
60.8
47.4
44.8
34.7
29.7
29.6
29.9
33.8
26.8
--
temperature T of winding:
--
t1 (°C)
--
R1 (Ω)
--
50.0
1:05
90V /
60Hz
normali
zed to
50
degree
C
ambien
t
62.1
65.1
75.5
76.2
75.9
75.4
76.5
84.0
70.6
68.0
57.9
52.9
52.8
53.1
57.0
50.0
1:12
24.6
-264V /
60Hz
34.7
35.6
39.9
36.6
39.7
39.3
40.6
57.4
45.4
42.3
32.5
27.9
27.8
28.1
30.5
25.9
--
t2 (°C) R2 ( Ω)
--
--
Verdict
50.0
2:18
264V /
60Hz
normali
zed to
50
degree
C
ambien
t
58.8
59.7
64.0
60.7
63.8
63.4
64.7
81.5
69.5
66.4
56.6
52.0
51.9
52.2
54.6
50.0
1:08
T (°C)
--
--
---
-
85
85
130
105
125
105
130
110
110
110
125
110
110
110
70
---
allowed insulation
class
Tmax
(°C)
--
--
supplementary information:
The temperatures were measured under worst-case normal mode defined in 1.2.2.1 and as described in 1.4.1
at voltages as described in 1.4.5
As per 1.4.12.3 for Non-temperature dependent equipment, T shall not exceed (Tmax + Tamb - Tma)
Tma = 45 degree C (the maximum ambient temperature permitted by the manufacturer's specification)
Tmax (Transformers, T1, T900), class B = 110 degree C
Tmax (LF1, LF2, L3, T2) = 130 degree C
Tmax (L100) = 105 degree C
Tmax (PWB) = 105 degree C
Tmax (Y-Capacitors, C3, C30) = 125 degree C
Tmax (X-Capacitors, C1, C2) = 85 degree C
Tmax (Electrolytic Capacitor, C5) = 85 degree C
Tmax (Bridge Capacitor, C31) = 125 degree C
User accessible area:
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 62 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
Tmax (metal enclosure) = 70 degree C
4.5.5
TABLE: Ball pressure test of thermoplastic parts
Pass
allowed allowed impression diameter (mm)......... : 2.0
—
part
test temperature (°C)
Terminal Block TB1, Switchlab , T35 series
125
impression diameter
(mm)
1.1
supplementary information:
--
4.7
TABLE: resistance to fire
part
--
Pass
manufacturer of
material
--
type of material
--
thickness
(mm)
flammability
class
--
--
Evidence
--
supplementary information:
See Critical Component List
5.2
TABLE: electric strength tests, impulse tests and voltage surge tests
Test voltage applied between:
Voltage shape
(AC, DC,
impulse, surge)
One layer of insulation, thickness 0.05mm *
T1 primary to secondary
T1 primary to core
T1 secondary to core
T900 primary to secondary
T900 primary to core
T900 secondary to core
Primary to SELV
Primary to Earth
Insulation Sheet (Type Formex GK from Formex;
Type FR700 from Sabic)
AC
AC
AC
AC
AC
AC
AC
DC
DC
AC
supplementary information:
* Tape tested:
3M Co.: 1350F-1, 1350T-1
Symbio Inc.: 35660, 35660Y
Bondtec Pacific Co., Ltd.: 370S
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Pass
Test voltage
(V)
3000
3000
1707
1707
3000
1707
1707
4242
3000
1500
Breakdown
Yes / No
No
No
No
No
No
No
No
No
No
No
Issue Date:
2010-05-19
Page 63 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
5.3
Component
No.
Requirement + Test
Result - Remark
Verdict
TABLE: fault condition tests
Pass
ambient temperature (°C) .................................. : --
—
Power source for EUT: Manufacturer, model/type, -output rating..................................................... :
—
Fault
Supply
voltage
(V)
Test time
Fuse
#
Fuse current
(A)
Observation
Model
-HRPG-4505
Fan
Stalled
--
--
--
--
--
240
1:42
FS1
8
Ventilation
openings
Blocked
240
1:32
FS1
8
+5V
Transformer
(T1) overload
Before J111
240
9;10
FS1
8
+5V
Transformer
(T1) overload
after D150
240
4:53
FS1
8
+5V
Transformer
(T1) overload
after D151
240
4:58
FS1
8
Unit Cycle protection, NT,
NC, NB
T1 coil:112 degree C T900
coil:69 degree C,
U4 body:73 degree C,
Amb:26.4 degree C ,
I/P: 0.13~2.21A
Unit Cycle protection, NT,
NC, NB
T1 coil:107 degree C, T900
coil:70 degree C,
U4 body:74 degree C,
Amb:25.3 degree C ,
I/P: 0.13~2.21A
CT at 25 A, (output load 90
A, total load :
115 A), increased to 30 A,
Unit shutdown, NT, NB, NC,
I/P: (3.05 A),
T1 coil:138 degree C, T900
coil: 65 degree C,
U4 body:71 degree C,
Amb:25.8 degree C
CT at 1 A, increased to 2 A,
Unit shutdown, NT, NB, NC,
I/P: (2.43 A),
T1 coil:127 degree C, T900
coil: 69 degree C,
U4 body:75 degree C,
Amb:25.1 degree C
CT at 1.5A, increased to 2.5
A, Unit shutdown, NT, NB,
NC, I/P: (2.39 A),
T1 coil:94 degree C, T900
coil: 54 degree C,
U4 body:55 degree C,
Amb:23.5 degree C
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 64 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
+5V
Transformer
overload after
D950
240
2:24
FS1
8
+5V - RTN
Short
240Vac
30 min
FS1
8
+5V
Overload
240Vac
7:14
FS1
8
Model
-HRPG-45012
Fan
Stalled
--
--
--
--
240
2:06
FS1
8
Ventilation
openings
Blocked
240
2:40
FS1
8
+12V
Transformer
(T1) overload
Before J111
240
10:21
FS1
8
+12V
Transformer
(T1) overload
after D150
240
11:00
FS1
8
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
CT at 0.5A, increased to 1
A, Unit shutdown, NT, NB,
NC, I/P: (2.35 A),
T1 coil:82 degree C, T900
coil: 48 degree C,
U4 body:48 degree C,
Amb:24.0 degree C
Unit shutdown, NT, NC, NB,
I/P:0.25A,
CT at 105 A, increased to
110 A,
Unit shutdown, NT, NB, NC,
I/P: ( 2.76 A),
T1 coil:107 degree C, T900
coil: 40 degree C, U4
body:61 degree C,
Amb:26.1 degree C
--
Unit Cycle protection, NT,
NC, NB
T1 coil:102 degree C, T900
coil:71 degree C,
U4 body:74 degree C,
Amb:27.3 degree C ,
I/P: 0.13~2.21A
Unit Cycle protection, NT,
NC, NB
T1 coil:99 degree C, T900
coil:75 degree C,
U4 body:80 degree C,
Amb:25.6 degree C ,
I/P: 0.13~2.21A
CT at 12A, (output load
37.5A)
total load :49.5A) increased
to 14A
Unit shutdown, NT, NB, NC,
I/P: (2.88A)
T1 coil:78 degree C T900
coil: 41 degree C
U4 body:43 degree C,
Amb:28.2 degree C
CT at 4 A, increased to 5 A,
Unit shutdown, NT, NB, NC,
I/P: (2.37 A),
T1 coil:84 degree C, T900
coil: 41 degree C,
Issue Date:
2010-05-19
Page 65 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
+12V
Transformer
(T1) overload
after D151
240
8:14
FS1
8
+12V RTN
+12V
Short
240Vac
30 min
FS1
8
Overload
240Vac
5:14
FS1
8
Model
-HRPG-45012 (+24V /
18.8A)
T1 pin 6 - 8 Short
--
--
--
--
240
1 sec
FS1
8
T1 pin 9 10
Short
240
1 sec
FS1
8
T1 pin FL1
- FL2
Short
240
1 sec
FS1
8
Model
-HRPG-45012 (+12V /
37.5A)
T1 pin 6 - 8 Short
--
--
--
--
240
1 sec
FS1
8
T1 pin 9 10
Short
240
1 sec
FS1
8
T1 pin FL1
- FL2
Short
240
1 sec
FS1
8
--
--
--
--
240
1 sec
FS1
8
Model
-HRPG-45012 (+5V /
90A)
T1 pin 6 - 8 Short
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
U4 body:46 degree C ,
Amb:23.7 degree C
CT at 2 A, increased to 2.5
A, Unit shutdown, NT, NB,
NC, I/P: (2.34 A),
T1 coil:70 degree C, T900
coil: 42 degree C,
U4 body:53 degree C,
Amb:24.7 degree C
Unit shutdown, NT, NC, NB,
I/P:0.25A,
CT at 43 A, increased to 45
A,
Unit shutdown, NT, NB, NC,
I/P: (2.50 A),
T1 coil: 60 degree C, T900
coil:30 degree C, U4
body:39 degree C,
Amb:25.1 degree C
--
IP(FS1) *, CD(Q3,Q4), NT,
NB, NC, I/P:0A
CD(T1), NT, NB, NC,
I/P:0.14A , Repeat 2 times,
result were same
IP(FS1) *,
CD(Q1,Q2,Q3,Q4), NT, NB,
NC, I/P:0A
--
IP(FS1) *, CD(Q3,Q4), NT,
NB, NC, I/P:0A
CD(T1), NT, NB, NC,
I/P:0.14A ,Repeat 2 times
,result were same
IP(FS1) *,
CD(Q1,Q2,Q3,Q4), NT, NB,
NC, I/P:0A
--
IP(FS1) *, CD(Q3,Q4), NT,
NB, NC, I/P:0A
Issue Date:
2010-05-19
Page 66 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
T1 pin 9 10
Short
240
1 sec
FS1
8
T1 pin FL1
- FL2
Short
240
1 sec
FS1
8
Model
-HRPG-45024
Fan
Stalled
--
--
--
--
240
2:16
FS1
8
Ventilation
openings
Blocked
240
2:07
FS1
8
+24V
Transformer
(T1) overload
Before J111
240
5;02
FS1
8
+24V
Transformer
(T1) overload
after D150
240
5:35
FS1
8
+24V
Transformer
(T1) overload
after D151
240
7:02
FS1
8
+24V RTN
+24V
Short
240Vac
30 min
FS1
8
Overload
240Vac
4:29
FS1
8
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
CD(T1), NT, NB ,NC,
I/P:0.14A , Repeat 2 times,
result were same
IP(FS1) *,
CD(Q1,Q2,Q3,Q4), NT, NB,
NC, I/P:0A
--
Unit Cycle protection, NT,
NC, NB
T1 coil:104 degree C, T900
coil:69 degree C,
U4 body:71 degree C,
Amb:27.1 degree C ,
I/P: 0.13~2.21A ,
Unit Cycle protection, NT,
NC, NB
T1 coil:104 degree C, T900
coil:72 degree C,
U4 body:74 degree C,
Amb:27.1 degree C ,
I/P: 0.13~2.21A ,
CT at 8 A, (output load 18.8
A, total
load :26.8A), increased to
10 A, Unit shutdown, NT,
NB, NC, I/P: (3.11 A),
T1 coil:96 degree C, T900
coil: 42 degree C,
U4 body:44 degree C,
Amb:26.0 degree C
CT at 1 A, increased to 2 A,
Unit shutdown, NT, NB, NC,
I/P: (2.25 A),
T1 coil:120 degree C, T900
coil: 70 degree C,
U4 body:80 degree C,
Amb:24.1 degree C
CT at 2 A, increased to 2.5
A, Unit shutdown, NT, NB,
NC, I/P: (2.26 A),
T1 coil:85 degree C, T900
coil: 42 degree C,
U4 body:48 degree C,
Amb:25.3 degree C
Unit shutdown, NT, NC, NB,
I/P:0.25A,
CT at 22A, increased to 24
Issue Date:
2010-05-19
Page 67 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Model
-HRPG-45048
Fan
Stalled
--
--
--
--
240
3:08
FS1
8
Ventilation
openings
Blocked
240
2:47
FS1
8
+48V
Transformer
(T1) overload
Before J111
240
11:37
FS1
8
+48V
Transformer
(T1) overload
after D150
240
5:31
FS1
8
+48V
Transformer
(T1) overload
after D151
240
6:38
FS1
8
+48V RTN
Short
240Vac
30 min
FS1
8
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
A,
Unit shutdown, NT, NB, NC,
I/P: ( 2.56 A),
T1 coil:55 ?, T900 coil: 34
degree C, U4 body:42
degree C, Amb:28.9 degree
C
--
Unit Cycle protection, NT,
NC, NB
T1 coil:119?, T900 coil:72
degree C,
U4 body:80 degree C,
Amb:27.1 degree C ,
I/P: 0.13~2.21A ,
Unit Cycle protection, NT,
NC, NB
T1 coil:112 degree C, T900
coil:75 degree C,
U4 body:81 degree C,
Amb:27.3 degree C ,
I/P: 0.13~2.21A ,
CT at 5 A, (output load 9.5
A, total
load :14.5A), increased to 6
A, Unit shutdown, NT, NB,
NC, I/P: (3.3 A),
T1 coil:118 degree C, T900
coil: 41 degree C,
U4 body:44 degree C,
Amb:25.1 degree C
CT at 1 A, increased to 2 A,
Unit shutdown, NT, NB, NC,
I/P: (2.29 A),
T1 coil:120 degree C T900
coil: 67 degree C,
U4 body:76 degree C,
Amb:24.4 degree C
CT at 2 A, increased to 2.5
A, Unit shutdown, NT, NB,
NC, I/P: (2.27 A),
T1 coil:78 degree C, T900
coil: 38 degree C,
U4 body:44 degree C,
Amb:25.5 degree C
Unit shutdown, NT, NC, NB,
I/P:0.25A,
Issue Date:
2010-05-19
Page 68 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
+48V
Requirement + Test
Overload
Result - Remark
240Vac
8:18
FS1
8
Model
-HRPG-45048 (+48V /
9.5A)
U2 SecShort
--
--
--
--
240
30 min
FS1
8
U2 Pri-
Short
240
30 min
FS1
8
U2 Pin 1
Open
240
30 min
FS1
8
U3 Sec-
Short
240
2h:57m
FS1
8
U3 Pri-
Short
240
30 min
FS1
8
U3 Pin 1
Open
240
2h:54m
FS1
8
U4 Sec-
Short
240
2h:46m
FS1
8
U4 Pri-
Short
240
30 min
FS1
8
U4 Pin 1
Open
240
2h:28m
FS1
8
T1 pin 6 - 8 Short
240
1 sec
FS1
8
T1 pin 9 -
240
1 sec
FS1
8
Short
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
CT at 12.5A, increased to
13.5 A,
Unit shutdown, NT, NB, NC,
I/P: ( 2.6A),
T1 coil:72 degree C, T900
coil: 45 degree C, U4
body:50 degree C,
Amb:24.4 degree C
--
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit Normal operation, NT,
NC, NB
T1= 57.5 degree C, T900=
27.9 degree C, U4= 46.2
degree C, Amb=25.1
degree C, I/P:2.17 A
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit Normal operation, NT,
NC, NB
T1= 59.8 degree C, T900=
29.8 degree C, U4= 48.0
degree C, Amb=26.9
degree C, I/P:2.17 A
Unit Normal operation, NT,
NC, NB
T1= 57.1 degree C, T900=
27.5 degree C, U4= 46.0
degree C, Amb= 24.8
degree C, I/P: :2.17A
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit Normal operation, NT,
NC, NB
T1= 55.1 degree C,
T900=25.2 degree C, U4=
43.5 degree C, Amb=23.3
degree C, I/P:2.17A
IP(FS1) *, CD(Q3,Q4), NT,
NB,NC, I/P:0A
CD(T1), NT, NB, NC,
Issue Date:
2010-05-19
Page 69 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
10
T1 pin FL1
- FL2
T900 pin 1
-2
T900 pin
FL1A - 4
T900 pin
5,6 -7,8
Short
240
30 min
FS1
8
Short
240
30 min
FS1
8
Short
240
30 min
FS1
8
Short
240
1h:53m
FS1
8
Q1 (G-S)
Short
240
2h:9m
FS1
8
Q1 (G-D)
Short
240
1 sec
FS1
8
Q1 (D-S)
Short
240
1 sec
FS1
8
Q2 (G-S)
Short
240
3h:0m
FS1
8
Q2 (G-D)
Short
240
1 sec
FS1
8
Q2 (D-S)
Short
240
1 sec
FS1
8
Q3 (G-S)
Short
240
30 min
FS1
8
Q3 (G-D)
Short
240
30 min
FS1
8
Q3 (D-S)
Short
240
1 sec
FS1
8
Q4 (G-S)
Short
240
30 min
FS1
8
Q4 (G-D)
Short
240
30 min
FS1
8
Q4 (D-S)
Short
240
1 sec
FS1
8
BD1 (L-+)
Short
240
1 sec
FS1
8
C5
Short
240
1 sec
FS1
8
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Verdict
I/P:0.14A , Repeat 2 times,
result were same
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit shutdown, NT, NB, NC,
I/P:0.15A,
Unit Normal operation, NT,
NC, NB
T1=55.2 degree C, T900=
25.4 degree C, U4= 43.7
degree C, Amb= 23.3
degree C, I/P:2.17A
Unit Normal operation, NT,
NC, NB
T1= 56.3 degree C,
T900=26.2 degree C, U4=
44.6 degree C, Amb= 24.6
degree C, I/P:2.17A
IP(FS1) *, CD(Q1,Q2), NT,
NB, NC, I/P:0A
IP(FS1) *,CD(Q1,Q2), NT,
NB, NC, I/P:0A
Unit Normal operation, NT,
NC, NB
T1=57.3 degree C, T900=
27.7 degree C, U4= 46.0
degree C, Amb=26.1
degree C, I/P: 2.17A
IP(FS1) *, CD(Q1,Q2), NT,
NB, NC, I/P:0A
IP(FS1) *, CD(Q1, Q2), NT,
NB, NC, I/P:0A
Unit shutdown, NT , NB,
NC, I/P:0.15A,
Unit shutdown, NT , NB,
NC, I/P:0.15A,
IP(FS1) *,CD(Q3), NT, NB,
NC, I/P:0A
Unit shutdown, NT, NB,
NC, I/P:0.15A,
Unit shutdown, NT, NB,
NC, I/P:0.15A,
IP(FS1) *, CD(Q4), NT, NB,
NC, I/P:0A
IP(FS1) *, CD(Q1,Q2), NT,
NB, NC, I/P:0A
IP(FS1) *, CD(Q1,Q2), NT,
Issue Date:
2010-05-19
Page 70 of 70
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
Clause
Requirement + Test
Result - Remark
Verdict
NB, NC, I/P:0A
supplementary information:
Results Key: IP = Internal protection operated (component indicated) CT = Constant temperatures were
obtained TW = Transformer winding opened CD = Components damaged (damaged components indicated)
NB = No indication of dielectric breakdown YB = Dielectric breakdown (time and location indicated) NC =
Cheesecloth remained intact YC = Cheesecloth charred or flamed NT = Tissue paper remained intact YT =
Tissue paper charred or flamed * : Test repeated with the following fuses, results were the same: Type UBM
from Conquer Electronics; Type 216 from Littelfuse; Type 5HF from Bel Fuse; Type FSC from Walter Electronic
TRF No. IECEN60950_1C
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 1 of 10
Report Reference #
Enclosure
National Differences
USA / Canada
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 2 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
USA / Canada - Differences to IEC 60950-1:2005, Second Edition
1.1
Equipment able to be installed in accordance with
the National Electrical Code ANSI/NFPA 70 and
the Canadian Electrical Code, Part1, and when
applicable, the National Electrical Safety Code,
IEEE C2.
Pass
1.1.1
Equipment able to be installed in accordance with
ANSI/NFPA 75 and NEC Art. 645 unless intended
for use outside of computer room and provided with
such instructions.
Pass
1.1.2
Equipment in wire-line communication facilities
serving high-voltage electric power stations
operating at greater than 1kV are excluded.
N/A
1.1.2
Special requirements apply to equipment intended
for use outdoors.
N/A
1.4.14
For Pluggable Equipment Type A, the protection in To be evaluated in end
the installation is assumed to be 20 A.
product.
N/A
1.5.1
All IEC standards for components identified in
Annex P.1 replaced by the relevant requirements of
CSA and UL component standards in Annex P.1.
Pass
1.5.1
All IEC standards for components identified in
Annex P.2 alternatively satisfied by the relevant
requirements of CSA and UL component standards
in Annex P.2.
Pass
1.5.5
Interconnecting cables acceptable for the
application regarding voltage, current, temperature,
flammability, mechanical serviceability and the like.
N/A
1.5.5
For other than limited power and TNV circuits, the
type of output circuit identified for output connector.
N/A
1.5.5
External cable assemblies that exceed 3.05 m in
length to be types specified in the NEC and CEC.
N/A
1.5.5
Detachable external interconnecting cables 3.05 m
or less in length and provided with equipment
marked to identify the responsible organization and
the designation for the cable.
N/A
1.5.5
Building wiring and cable for use in ducts, plenums
and other air handling space subject to special
requirements and excluded from scope.
N/A
1.5.5
Telephone line and extension cords and the like
comply with UL 1863 and CSA C22.2 No. 233.
N/A
1.6.1.2
Equipment intended for connection to a d.c. power
(mains) distribution system is subject to special
N/A
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 3 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
circuit classification requirements (e.g., TNV -2)
1.6.1.2
Earthing of d.c. powered equipment provided.
N/A
1.7
Lamp replacement information indicated on
lampholder in operator access area.
N/A
1.7.1
Special marking format for equipment intended for
use on a supply system with an earthed neutral
and more than one phase conductor.
N/A
1.7.1
Equipment voltage rating not higher than rating of
the plug except under special conditions.
1.7.6
Special fuse replacement marking for operator
accessible fuses.
1.7.7
Identification of terminal connection of the
equipment earthing conductor.
1.7.7
Connectors and field wiring terminals for external
Class 2 or Class 3 circuits provided with marking
indicating minimum Class of wiring to be used.
1.7.7
Marking located adjacent to terminals and visible
during wiring.
2.1.1.1
Bare TNV conductive parts in the interior of
equipment normally protected against contact by a
cover intended for occasional removal are exempt
provided instructions include directions for
disconnection of TNV prior to removal of the cover.
N/A
2.3.1.b
Other telecommunication signaling systems (e.g.,
message waiting) than described in 2.3.1(b) are
subject to M.4.
N/A
2.3.1.b
For TNV -2 and TNV-3 circuits with other than
ringing signals and with voltages exceeding 42.4
Vp or 60 V d.c., the maximum current limit through
a 2000 Ohm or greater resistor with loads
disconnected is 7.1 mA peak or 30 mA d.c. under
normal conditions.
N/A
2.3.1.b
Limits for measurements across 5000 ohm resistor
in the event of a single fault are replaced after 200
ms with the limits of M.3.1.4.
N/A
2.3.2.1
In the event of a single fault, the limits of 2.2.3
apply to SELV circuits and accessible conductive
parts.
N/A
2.3.2.4
Enamel coating on signal transformer winding wire
allowed as an alternative to Basic insulation in
specific telecommunication applications when
subjected to special construction requirements and
N/A
Not used.
N/A
N/A
To be evaluated in end
product.
N/A
N/A
To be evaluated in end
product.
Underwriters Laboratories Inc.
N/A
Issue Date:
2010-05-19
Page 4 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
routine testing.
2.5
Overcurrent protection device required for Class 2
and Class 3 limiting in accordance with the NEC, or
for a Limited Power Source, not interchangeable
with devices of higher ratings if operator
replaceable.
N/A
2.6
Equipment having receptacles for output a.c. power
connectors generated from an internal separately
derived source have the earthed (grounded) circuit
conductor suitably bonded to earth.
N/A
2.6.3.3
For Pluggable Equipment Type A, if a) b) or c) are
not applicable, the current rating of the circuit is
taken as 20 A
N/A
2.6.3.4
Capacity of connection between earthing terminal To be evaluated in end
and parts required to be earthed subject to special product.
conditions based on the current rating of the circuit.
N/A
2.6.3.4
Protective bonding conductors and their terminals
of non-standard constructions (e.g. PWB traces)
evaluated to limited short-circuit test of CSA C22.2
No.0.4.
N/A
2.6.4.1
Field wiring terminals for earthing conductors
suitable for wire sizes (gauge) used in US and
Canada.
N/A
2.7.1
Data for selection of special external branch circuit
overcurrent devices marked on the equipment.
N/A
2.7.1
Standard supply outlets protected by overcurrent
device in accordance with the NEC, and CEC, Part
1.
N/A
2.7.1
Overcurrent protection for individual transformers
that distribute power to other units over branch
circuit wiring.
N/A
2.7.1
Additional requirements for overcurrent protection
apply to equipment provided with panelboards.
N/A
2.7.1
Non-motor-operated equipment requiring special
overcurrent protective device marked with device
rating.
N/A
2.10.5.12
Multi-layer winding wire subject to UL component
wire requirements in addition to 2.10.5.12 and
Annex U.
N/A
3.1.1
Permissible combinations of internal wiring/external
PWB traces are not evaluated
to limited short-circuit test of
CSA C22.2 No. 0.4. Proper
bonding to the end-product
main protective earthing
termination is required.
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 5 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
cable sizes for overcurrent and short circuit
protection.
3.1.1
All interconnecting cables protected against
overcurrent and short circuit.
N/A
3.2
Wiring methods permit connection of equipment to
primary power supply in accordance with the NEC
and CEC, Part 1.
3.2.1
Permitted use for flexible cords and plugs.
N/A
3.2.1
Flexible cords provided with attachment plug rated
125% of equipment current rating.
N/A
3.2.1
Any Class II equipment provided with 15 or 20 A
standard supply outlets, Edison-base lampholders
or single pole disconnect device provided with a
polarized type attachment plug.
N/A
3.2.1.2
Equipment intended for connection to DC mains
supply power systems complies with special wiring
requirements (e.g., no permanent connection to
supply by flexible cord).
N/A
3.2.1.2
Equipment with one pole of the DC mains supply
connected to both the equipment mains input
terminal and the main protective earthing terminal
provided with special instructions and construction
provisions for earthing
N/A
3.2.1.2
Equipment with means for connecting supply to
earthing electrode conductor has no switches or
protective devices between supply connection and
earthing electrode connection.
N/A
3.2.1.2
Special markings and instructions for equipment
with provisions to connect earthed conductor of a
DC supply circuit to earthing conductor at the
equipment.
N/A
3.2.1.2
Special markings and instructions for equipment
with earthed conductor of a DC supply circuit
connected to the earthing conductor at the
equipment.
N/A
3.2.1.2
Terminals and leads provided for permanent
connection of DC powered equipment to supply
marked to indicate polarity if reverse polarity may
result in a hazard.
N/A
3.2.3
Permanently connected equipment has provision
for connecting and securing a field wiring system
(i.e. conduit, or leads etc.) per the NEC and CEC,
Pass
To be evaluated in end
product.
Underwriters Laboratories Inc.
N/A
Issue Date:
2010-05-19
Page 6 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
Part 1.
3.2.3
Permanently connected equipment may have
terminals or leads not smaller than No. 18 AWG
(0.82 mm²) and not less than 150 mm in length for
connection of field installed wiring.
N/A
3.2.3
If supply wires exceed 60 °C, marking indicates
use of 75 °C or 90 °C wiring for supply connection
as appropriate.
N/A
3.2.3
Equipment compatible with suitable trade sizes of
conduits and cables.
N/A
3.2.5
Length of power supply cord limited to between 1.5
and 4.5 m unless shorter length used when
intended for a special installation.
N/A
3.2.5
Conductors in power supply cords sized according
to NEC and CEC, Part I.
N/A
3.2.5
Power supply cords and cord sets incorporate
flexible cords suitable for the particular application.
N/A
3.2.6
Strain relief provided for non-detachable
interconnecting cables not supplied by a limited
power source.
N/A
3.2.9
Adequate wire bending space and volume of field
wiring compartment required to properly make the
field connections.
N/A
3.2.9
Equipment intended solely for installation in
Restricted Access Locations using low voltage d.c.
systems may not need provision for connecting and
securing a field wiring system. A method of
securing wiring or instructions provided to ensure
the wiring is protected from abuse.
N/A
3.3
Field wiring terminals provided for interconnection
of units for other then LPS or Class 2 circuits also
comply with 3.3.
N/A
3.3
Interconnection of units by LPS or Class 2
conductors may have field wiring connectors other
than those specified in 3.3 if wiring is reliably
separated.
N/A
3.3.1
Terminals for the connection of neutral conductor
identified by a distinctive white marking or other
equally effective means.
3.3.3
Wire binding screw terminal permitted for
connection of No. 10 AWG (5.3 mm²) or smaller
conductor if provided with upturned lugs, cupped
To be evaluated in end
product.
Underwriters Laboratories Inc.
N/A
Pass
Issue Date:
2010-05-19
Page 7 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
washer or equivalent retention.
3.3.4
Terminals accept wire sizes (gauge) used in the
U.S. and Canada.
To be evaluated in end
product.
3.3.4
Terminals accept current-carrying conductors rated
125% of the equipment current rating.
3.3.6
Field wiring terminals marked to indicate the
material(s) of the conductor appropriate for the
terminals used.
N/A
3.3.6
Connection of an aluminum conductor not
permitted to terminal for equipment earthing
conductor.
N/A
3.3.6
Field wiring connections made through the use of
suitable pressure connectors (including set screw
type), solder lugs or splices to flexible leads.
N/A
3.4.2
Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with
motor rated more than 1/3 hp or more than 120 V.
N/A
3.4.8
Vertically mounted disconnect devices oriented so
up position of handle is "on".
N/A
3.4.11
For computer-room applications, equipment with
battery systems capable of supplying 750 VA for 5
min require battery disconnect means.
N/A
4.2.8.1
Special opening restrictions for enclosures around
CRTs with face dimension of 160 mm or more.
N/A
4.2.9
Compartment housing high-pressure lamp marked
to indicate risk of explosion.
N/A
4.2.11
For equipment intended for mounting on racks and
provided with slide/rails allowing the equipment to
slide away from the rack for installation, service
and maintenance, additional construction,
performance and marking requirements are
applicable to determine the adequacy of the
slide/rails.
N/A
4.3.2
Loading test for equipment with handle(s) used to
support more than 9 kg tested at four times the
weight of the unit.
N/A
4.3.6
In addition to the IEC requirements, Direct Plug-in
Equipment complies with UL 1310 or CSA 223
mechanical assembly requirements.
N/A
4.3.12
The maximum quantity of flammable liquid stored
in equipment complies with ANSI/NFPA 30(Table
NAE.6).
N/A
Underwriters Laboratories Inc.
Pass
Pass
Issue Date:
2010-05-19
Page 8 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
4.3.12
Equipment using replenishable liquids marked to
indicate type of liquid to be used.
N/A
4.3.13.2
Equipment that produces x-radiation and does not
comply with 4.3.12 under all conditions of servicing
marked to indicate the presence of radiation where
readily visible.
N/A
4.3.13.5
Requirements contained in the applicable national
codes and regulations apply to lasers (21 CFR
1040 and REDR C1370).
N/A
4.7
Automated information storage equipment intended
to contain more than 0.76 m³ of combustible media
requires provision for automatic sprinklers or a
gaseous agent extinguishing system.
N/A
4.7.3.1
Equipment for use in environmental air space other
than ducts or plenums provided with metal
enclosure or with non-metallic enclosure having
adequate fire-resistance and low smoke producing
characteristics. Low smoke-producing
characteristics evaluated according to UL 2043.
Equipment for installation in space used for
environmental air as described in Sec. 300-22(c) of
the NEC provided with instructions indicating
suitability for installation in such locations.
N/A
4.7.3.1
Flame spread rating for external surface of
combustible material with exposed area greater
than 0.93 m² or a single dimension greater than 1.8
m; 50 or less for computer room applications or
200 or less for other applications.
N/A
4.7.3.4
Wire marked "VW-1" or "FT-1" considered
equivalent.
5.1.8.2
Special earthing provisions and instructions for
equipment with high touch current due to
telecommunication network connections.
N/A
5.1.8.3
Touch current due to ringing voltage for equipment
containing telecommunication network leads.
N/A
5.3.7
Overloading of SELV connectors and printed wiring
board receptacles accessible to the operator.
Pass
5.3.7
Tests interrupted by opening of a component
repeated two additional times.
Pass
5.3.9.1
Test interrupted by opening of wire or trace subject
to certain conditions.
N/A
6
Specialized instructions provided for telephones
that may be connected to a telecommunications
N/A
Underwriters Laboratories Inc.
Pass
Issue Date:
2010-05-19
Page 9 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
network.
6
Marking identifying function of telecommunication
type connectors not used for connection to a
telecommunication network.
N/A
6.3
Equipment remotely powered over
telecommunication wiring systems provided with
specialized markings adjacent to the connection.
N/A
6.3
Overcurrent protection incorporated into equipment
to provide power over telecommunication wiring
system not interchangeable with devices of higher
ratings if operator replaceable.
N/A
6.4
Additional requirements for equipment intended for
connection to a telecommunication network using
cable subject to overvoltage from power line
failures (Fig. 6C).
N/A
6.4
Where 26 AWG line cord required by Fig. 6C,
either the cord is provided with the equipment or
described in the safety instructions.
N/A
7
Equipment associated with the cable distribution
system may need to be subjected to applicable
parts of Chapter 8 of the NEC.
N/A
H
Ionizing radiation measurements made under
single fault conditions in accordance with the
requirements of the Code of Federal Regulations
21 CFR 1020 and the Canadian Radiation Emitting
Devices Act, REDR C1370.
N/A
M.2
Continuous ringing signals evaluated to Method A
subjected to special accessibility considerations.
N/A
M.4
Special requirements for message waiting and
similar telecommunications signals.
N/A
NAC
Equipment intended for use with a generic
secondary protector marked with suitable
instructions.
N/A
NAC
Equipment intended for use with a specific primary
or secondary protector marked with suitable
instructions.
N/A
NAD
Acoustic pressure from an ear piece less than 136
dBA for short duration disturbances, and less than
125 dBA for handsets, 118 dBA for headsets, and
121 dBA for insert earphones, for long duration
disturbances.
N/A
NAD
Equipment connected to a telecommunication and
N/A
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 10 of 10
Report Reference #
E183223-A123-UL-1
IEC 60950-1:2005
SubClause Difference + Test
Result - Remark
Verdict
cable distribution networks and supplied with an
earphone intended to be held against, or in the ear
is required to comply with special acoustic pressure
requirements.
NAF
Household/Home Office Document Shredders
N/A
NAF.1.7
Markings and instructions alert the user to key
safety considerations related to use of shredders,
including not intended to be used by children, avoid
touching document feed opening, avoid clothes
and hair entanglement, and avoid aerosol products.
N/A
NAF.2.8.3
Safety interlock cannot be inadvertently activated
by the articulated accessibility probe (figure
NAF.1).
N/A
NAF.3.4
Provided with an isolating switch complying with
3.4.2, including 3 mm contact gap, with appropriate
markings associated with the switch.
N/A
NAF.4.4
Hazardous moving parts are not accessible, as
determined using the articulated accessibility probe
(figure NAF.1) and the accessibility probe/wedge
(figures NAF.2/NAF.3).
N/A
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 1 of 11
Report Reference #
Enclosure
Photographs
Supplement Id
Description
3-01
External View 1
3-02
External View 2
3-03
Internal View with Chassis 1
3-04
Internal View with Chassis 2
3-05
Main PWB Components
3-06
Main PWB Traces
3-07
Constrol PWB Components
3-11
Control PWB Traces
3-12
Small Secondary PWB Top
3-13
Small Secondary PWB Bottom
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 2 of 11
Report Reference #
Photographs ID 3-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 3 of 11
Report Reference #
Photographs ID 3-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 4 of 11
Report Reference #
Photographs ID 3-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 5 of 11
Report Reference #
Photographs ID 3-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 6 of 11
Report Reference #
Photographs ID 3-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 7 of 11
Report Reference #
Photographs ID 3-06
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 8 of 11
Report Reference #
Photographs ID 3-07
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 9 of 11
Report Reference #
Photographs ID 3-11
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 10 of 11
Report Reference #
Photographs ID 3-12
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 11 of 11
Report Reference #
Photographs ID 3-13
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 1 of 11
Report Reference #
E183223-A123-UL-1
Enclosure
Diagrams
Supplement Id
Description
4-01
Enclosure drawings
4-02
Heatsink drawing (HS1)
4-03
Heatsink drawing (HS2)
4-04
Heatsink drawing (HS3)
4-05
Heatsink drawing (HS4)
4-10
Heatsink drawing (for Thermal Switch)
4-11
Insulation Sheet on Top Chassis near L100
4-12
Insulation Sheet on Top Chassis above C5 and L3
4-13
Insulation Sheet between PWBs Traces and Bottom Chassis
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 2 of 11
Report Reference #
Diagrams ID 4-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 3 of 11
Report Reference #
Diagrams ID 4-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 4 of 11
Report Reference #
Diagrams ID 4-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 5 of 11
Report Reference #
Diagrams ID 4-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 6 of 11
Report Reference #
Diagrams ID 4-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 7 of 11
Report Reference #
Diagrams ID 4-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 8 of 11
Report Reference #
Diagrams ID 4-10
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 9 of 11
Report Reference #
Diagrams ID 4-11
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 10 of 11
Report Reference #
Diagrams ID 4-12
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 11 of 11
Report Reference #
Diagrams ID 4-13
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 1 of 19
Report Reference #
Enclosure
Schematics + PWB
Supplement Id
Description
5-01
Schematics and Component Differences
5-02
PWBs layouts
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 2 of 19
Report Reference #
Schematics ID 5-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 3 of 19
Report Reference #
Schematics ID 5-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 4 of 19
Report Reference #
Schematics ID 5-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 5 of 19
Report Reference #
Schematics ID 5-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 6 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 7 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 8 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 9 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 10 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 11 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 12 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 13 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 14 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 15 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 16 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 17 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 18 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 19 of 19
Report Reference #
Schematics ID 5-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 1 of 107
Report Reference #
Enclosure
Miscellaneous
Supplement Id
Description
7-01
Spec for transformer T1 from Jet Signal
7-02
Spec for transformer T1 from Elytone
7-03
Spec for transformer T1 from Long Sail
7-04
Spec for transformer T900 from Jet Signal
7-05
Spec for transformer T900 from Elytone
7-06
Spec for transformer T900 from Long Sail
7-07
Spec for Inductors LF1 LF2
7-08
Spec for Inductor L3
7-09
Spec for Inductor T2 TR -435
7-10
Spec for Inductor T2 TR -852
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 2 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 3 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 4 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 5 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 6 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 7 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 8 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 9 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 10 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 11 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 12 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 13 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 14 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 15 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 16 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 17 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 18 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 19 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 20 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 21 of 107
Report Reference #
Misc ID 7-01
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 22 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 23 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 24 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 25 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 26 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 27 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 28 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 29 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 30 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 31 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 32 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 33 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 34 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 35 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 36 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 37 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 38 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 39 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 40 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 41 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 42 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 43 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 44 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 45 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 46 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 47 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 48 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 49 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 50 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 51 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 52 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 53 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 54 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 55 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 56 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 57 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 58 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 59 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 60 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 61 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 62 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 63 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 64 of 107
Report Reference #
Misc ID 7-02
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 65 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 66 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 67 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 68 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 69 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 70 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 71 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 72 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 73 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 74 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 75 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 76 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 77 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 78 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 79 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 80 of 107
Report Reference #
Misc ID 7-03
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 81 of 107
Report Reference #
Misc ID 7-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 82 of 107
Report Reference #
Misc ID 7-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 83 of 107
Report Reference #
Misc ID 7-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 84 of 107
Report Reference #
Misc ID 7-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 85 of 107
Report Reference #
Misc ID 7-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 86 of 107
Report Reference #
Misc ID 7-04
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 87 of 107
Report Reference #
Misc ID 7-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 88 of 107
Report Reference #
Misc ID 7-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 89 of 107
Report Reference #
Misc ID 7-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 90 of 107
Report Reference #
Misc ID 7-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 91 of 107
Report Reference #
Misc ID 7-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 92 of 107
Report Reference #
Misc ID 7-05
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 93 of 107
Report Reference #
Misc ID 7-06
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 94 of 107
Report Reference #
Misc ID 7-06
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 95 of 107
Report Reference #
Misc ID 7-06
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 96 of 107
Report Reference #
Misc ID 7-06
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 97 of 107
Report Reference #
Misc ID 7-06
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 98 of 107
Report Reference #
Misc ID 7-07
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 99 of 107
Report Reference #
Misc ID 7-07
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 100 of 107
Report Reference #
Misc ID 7-08
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 101 of 107
Report Reference #
Misc ID 7-08
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 102 of 107
Report Reference #
Misc ID 7-09
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 103 of 107
Report Reference #
Misc ID 7-09
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 104 of 107
Report Reference #
Misc ID 7-09
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 105 of 107
Report Reference #
Misc ID 7-10
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 106 of 107
Report Reference #
Misc ID 7-10
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 107 of 107
Report Reference #
Misc ID 7-10
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 1 of 4
Report Reference #
Enclosure
Test Record
Description
Test Record 1
CRD
Datasheet
Underwriters Laboratories Inc.
E183223-A123-UL-1
Issue Date:
2010-05-19
Page 2 of 4
Report Reference #
E183223-A123-UL-1
Test Record No. 1
--The manufacturer submitted representative production samples of Switching Power Supplies, Models
HRPX-450-Y (X=G or blank; Y=3.3, 5, 7.5, 12, 15, 24, 36, 48).
--The results of this investigation, including construction review and testing, indicate that the products
evaluated comply with the applicable requirements in the U.S. and Canadian (Bi-National) Standard for
Safety of Information Technology Equipment, Including Electrical Business Equipment CAN/CSA-C22.2
No. 60950-1-07 and UL60950-1 Second Edition, date March 27, 2007.
--All tests were conducted by PSE Inc. Taiwan located at San Chung City, Taipei, Taiwan under the
TPTDP program.
--Test results reported relate only to the items tested.
--The following tests conducted in accordance with UL60950-1, 2nd Edition, Revised Date March 27,
2007, Information Technology Equipment-Safety-Part 1: General Requirements were considered
representative of the same tests required by Canadian Standards, CAN/CSA-C22.2 No.60950-1-07, 2nd
Edition, Date March, 2007, Information Technology Equipment-Safety-Part 1: General Requirements.
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 3 of 4
Report Reference #
E183223-A123-UL-1
The following tests were conducted:
Test
Testing Location/Comments
End Product Reference Page
General Guidelines
Power Supply Reference Page
Maximum Output Voltage, Current, and Volt-Ampere Measurement
(1.2.2.1)
Input: Single-Phase (1.6.2)
Durability of Marking (1.7.11)
Energy Hazard Measurements (2.1.1.5, 2.1.2, 1.2.8.10)
Capacitance Discharge (2.1.1.7)
SELV Reliability (2.2.2, 2.2.3, 2.2.4, Part 22 6.1)
Limited Current Circuit Measurement (2.4.1, 2.4.2)
Protective Bonding I (2.6.3.4, 2.6.1).7)
Protective Bonding II (2.6.3.4, 2.6.1)
Humidity (2.9.1, 2.9.2, 5.2.2)
Determination of Working Voltage; Working Voltage Measurement
(2.10.2)
Determination of Working Voltage; Hazardous Voltage (Circuit)
Measurement (2.10.2, Part 22 6.1)
Transformer and Wire /Insulation Electric Strength (2.10.5.6,
2.10.5.13)
Thin Sheet Material (2.10.5.9, 2.10.5.10, 2.10.5.6)
Heating (4.5.1, 1.4.12, 1.4.13)
Ball Pressure (4.5.5, 4.5)
Touch Current (Single-Phase; TN/TT System) (5.1, Annex D)
Electric Strength (5.2.2)
Component Failure (5.3.1, 5.3.4, 5.3.7)
Abnormal Operation (5.3.1 - 5.3.9)
Transformer Abnormal Operation (5.3.3, 5.3.7b, Annex C.1)
Power Supply Output Short-Circuit/Overload (5.3.7)
Test results are valid only for the tested equipment. These tests are considered representative of the
products covered by this Test Report. The test methods and results of the above tests have been reviewed
and found to be in accordance with the requirements in the Standard(s) referenced at the beginning of this
Test Report.
Underwriters Laboratories Inc.
Issue Date:
2010-05-19
Page 4 of 4
Report Reference #
Underwriters Laboratories Inc.
E183223-A123-UL-1