Agilent PC Bundle Set-up Guide Date: April 2015 Product Number: M8380AA, M8381AA, G61x0AA Product: Agilent PC Bundle (with OpenLAB CDS ChemStation Edition) 1 First time boot-up of the Agilent bundle PC The Agilent bundle PC comes with a pre-installed OpenLAB CDS software. During installation in the factory the PC name was WIN-HVM5U5T7EEK. When you start this PC the first time, an internal script is activated. The user is prompted to select the keyboard layout, the geography and the time zone. In the second screen the user is prompted to create a user name and password. This user name will be reflected in the PC name. If the PC workstation will not be part of a network (that is, if duplicate PC names are not an issue), the easiest procedure would be to make WIN-HVM5U5T7EEK the PC name. Example: As a user name the name John is entered. The PC name will be HP-JOHN. Clear HP-JOHN and replace it by WIN-HVM5U5T7EEK PC Name different from WIN-HVM5U5T7EEK: A change of the PC name may be scheduled to avoid duplicate names in a network or can be due to a policy change. When a PC name is changed after installation of OpenLAB CDS, there are some consequences that need to be considered. If this PC workstation is part of a network, or if you need to change the PC name for other reasons please carefully read the information below. 2 What happens when the name of a PC running OpenLAB CDS is changed? A change of the PC name may be scheduled to avoid duplicate names in a network or can be due to a policy change. When a PC name is changed after installation of OpenLAB CDS, there are some consequences that need to be considered. A: The license file for a PC is no longer valid OpenLAB CDS instruments are licensed by installing files that are specifically created for a given configuration. The text of the license files contains references to the computer name and the hardware address of the network card. If one of the parameters is changed, the license no longer applies. B: The instrument controller will no longer be resolved An instrument controller is a workstation or AIC that is used to control an instrument. This can be either a physical instrument for acquisition or for Data Analysis only. During installation of a standalone workstation the PC name of this workstation is registered as the Instrument Controller. If the name is changed after installation, the registered name is not updated automatically. Instead the old name remains as an unresolved orphan and instruments that are configured with this name will no longer start. 3 Solution Depending on whether the name change was intentional or not, whether it already occurred or is yet to happen, there are different steps that have to be executed. If the name change was not intended: Revert to the PC name as it has been before. NOTE: The old name can be found in the list of instrument controllers in the Administration section in the OpenLAB Control Panel. Page | 2 If the name change was intended: 1. Remove the old name of the instrument controller from the list of instrument controllers in the Administration section in the OpenLAB CDS Control Panel. NOTE: This step can be done only for controllers that have no instruments assigned to them. Any instruments need to be deleted first. 2. After the change to the new name you need to register this new PC name with OpenLAB Shared Services. This is done by executing the file RegisterCS.bat in the ChemStation Core folder: 3. If instruments have been deleted, re-create them now. 4. The final step would then be to install a license file that is generated with the new PC name (host name). Page | 3 Flowchart YES NO Has the PC name been changed already? NO NO Are instruments present? Are instruments present? YES YES Undo name change Delete Instruments Delete Instruments Change PC name to desired name Delete unresolved controller Execute RegisterCS.bat Create new Instruments Page | 4 Help and Support Using Online Help Online Help can be accessed using via F1 within any open user interface interacting with Agilent OpenLAB CDS Software. Getting Support Please contact your local Agilent Technologies Customer Care Center to obtain support. For details please visit the following web page: http://www.agilent.com/chem/contactus. Agilent Technologies also provides electronic support through the World Wide Web via http://www.agilent.com/chem. In any communication with the Software support team regarding a problem with this OpenLAB CDS bundle, please clearly state the following: Your name, address, e-mail address and telephone number. Your OpenLAB CDS product name and version number. Both are listed in Help and About. A description of the problem, and what you were trying to do when the problem occurred. *M8380-90000* *M8380-90000* Part Number: M8380-90000 M8380-90000 Edition 04 / 2015 Printed in Germany © Agilent Technologies, Inc. 2015 Agilent Technologies Hewlett-Packard-Strasse 8 76337 Waldbronn, Germany