metal leaflet Lay-In LAY-IN Board 02 LAY-IN microlook 07 LAY-IN tegular 14 LAY-IN axal vector 23 R-L 201 SYSTEM 30 Metal product LAY-IN Board Square & rectangular tiles 3 :::: LAY-IN board SQUARE & RECTANGULAR TILES BENEFITS n Diversity of design and application n Easily assembled and fully demountable n Cost effective ceiling solution n Tiles are easily lifted out by hand, allowing full and easy access to the ceiling void. APPLICATION AREA n Used in a variety of ceiling areas: from small service rooms to large commercial office buildings and major transportation terminals. Specification System Armstrong ceiling system Board, Lay-In solution with visible grid 24 mm Perimeter solution Range of standards trims in steel and aluminium plus custom bulkheads available Tile material galvanised steel sheet 0.5 mm (aluminium or other materials on request) Service integration standard round or rectangular cut-outs plus customised options on request. Execution* square tile square edged with standard notching Standard modules 600 x 600 mm 625 x 625 mm 1200 x 600 mm Grid system tested modular system Prelude TLX 24 further suspension methods on request Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Gap solution 0 mm gap, without gasket Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns Ultra Microperforation Rg 0501 Hole diameter: 0.5 mm Free area: 0.64 % Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% :::: 4 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a variety of factory fitted acoustic infill options. Please contact us for more information. Standard colours RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Thermal Conductivity (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Sustainability Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Environmental Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Acoustics Safe & Healthy % ISO 14021 Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity Resistance (%) up to Cleanability up to Bioguard paint option Scratch resistance Ultra Microperforation Rg 0501 (1) up to 30 83 0.45(L) D 0.55 18 8 A1 95 scrubbable ✔ ✔ Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) ✔ ✔ Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standardperforated Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Premium B15 up to 30 depends on perforation 0.65 C 0.60 47 21 A2-s1, d0 95 wipeable moist cloth ✔ Premium OP19 up to 30 depends on perforation 1.00 A 0.90 31 15 A2-s2, d0 95 wipeable moist cloth ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ 5 :::: Cross-section BOARD Quick hanger Ceiling Void Cross Tee Board square/ rectangular tile Main Runner Cross Tee Visible side Perimeter trim max. M Longitudinal-section BOARD Quick hanger Ceiling Void Board square/ rectangular tile Perimeter trim M = module size / A = panel length / B = panel width Cross Tee Main Runner Visible side :::: 6 Detail A Board square tile Detail B Prelude 24 TLX grid option Detail C Prelude 15 TL grid option Prelude 24 Main Runner Prelude 15 Main Runner Prelude 15 TL Cross Tee Prelude 24 TLX Cross Tee For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet Detail D suspension methods Suspension wire Suspension angle Suspension hanger for T-bar Quick hanger Bent T-bar hanger with threaded rod Nonius hanger Metal product LAY-IN MicroLook Square & rectangular tiles BENEFITS n Diversity of design and application n Easily assembled and fully demountable n Cost effective ceiling solution n Tiles are easily lifted out by hand, allowing full and easy access to the ceiling void. APPLICATION AREA n Used in a variety of ceiling areas: from small service rooms to large commercial office buildings and major transportation terminals. Project: Barnet College (UK) :::::::: Architect: Perkins Ogden Architects SOLUTION: Lay-In MicroLook with Microperforation :::: 9 LAY-IN microlook SQUARE & RECTANGULAR TILES Specification System Armstrong ceiling system MicroLook 8 & 16 Lay-In solution with visible grid 15 mm Panels Material galvanised steel sheet 0.5 mm (0.6 mm for module 750 x 750 mm) (aluminium or further materials on request) Execution* square tile square edged with 8 mm or 16 mm drop and standard notching Standard modules MicroLook 8: 500 x 500 mm 675 x 675 mm 300 x 1200 mm 600 x 600 mm 750 x 750 mm 600 x 1200 mm MicroLook 16: 500 x 500 mm 675 x 675 mm 600 x 600 mm 750 x 750 mm Grid system tested modular system Prelude TL 15 / XL2 15, 15. Optional design grid Silhouette or Interlude. Further suspension methods on request Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Perimeter solution Range of standards trims in steel and aluminium plus custom bulkheads available Service integration standard round or rectangular cut-outs plus customized options on request. MicroLook 8 * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet MicroLook 16 standard perforation patterns Ultra Microperforation Rg 0501 Hole diameter: 0.5 mm Free area: 0.64 % Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 10 :::: Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a variety of factory fitted acoustic infill options. Please contact us for more information. Standard colours RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Thermal Conductivity (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Sustainability Armstrong is a certified EN ISO 9001:2008 Quality Assumed Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Environmental Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Acoustics Safe & Healthy % ISO 14021 Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity Resistance (%) up to Cleanability up to Bioguard paint option Scratch resistance Ultra Microperforation Rg 0501 (1) up to 30 83 0.45(L) D 0.55 18 8 A1 95 scrubbable ✔ ✔ Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) ✔ ✔ Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standardperforated Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Premium B15 up to 30 depends on perforation 0.65 C 0.60 47 21 A2-s1, d0 95 wipeable moist cloth ✔ Premium OP19 up to 30 depends on perforation 1.00 A 0.90 31 15 A2-s2, d0 95 wipeable moist cloth ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ :::: 11 Cross-section MICROLOOK 8 Quick hanger ceiling void MicroLook 8 square/ rectangular tile Main Runner Cross Tee Cross Tee Visible side Perimeter trim Longitudinal-section MICROLOOK 8 Quick hanger ceiling void MicroLook 8 square/ rectangular tile Perimeter trim M = module size / A = panel length / B = panel width Cross Tee Main Runner Visible side 12 :::: Cross-section MICROLOOK 16 Quick hanger Ceiling void MicroLook 16 Square tile Main Runner Cross Tee Cross Tee Visible side Perimeter trim Longitudinal-section MICROLOOK 16 Quick hanger Ceiling void MicroLook 16 Square tile Perimeter trim M = module size / A = panel length / B = panel width Cross Tee Main Runner Visible side :::: 13 Detail A MicroLook 8 square tile option Detail B MicroLook 16 square tile Detail C grid system Detail D grid system Detail E Design grid Silhouette 15 XL² Prelude 15 Main Runner Prelude 15 Main Runner With 3 mm reveal With 6 mm reveal Detail F Design grid Interlude 15 XL² Prelude 15 XL² Cross Tee Prelude 15 TL Cross Tee For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet Detail G suspension methods Suspension wire Suspension angle Suspension hanger Quick hanger for T-bar Bent T-bar hanger with threaded rod Nonius hanger Metal product LAY-IN Tegular Square & rectangular tiles BENEFITS n Diversity of design and application n Easily assembled and fully demountable n Cost effective ceiling solution n Tiles are easily lifted out by hand, allowing full and easy access to the ceiling void. APPLICATION AREA n Used in a variety of ceiling areas: from small service rooms to large commercial office buildings and major transportation terminals. Project: Leman Cake Decorations :::::::: Architect: Didier Leman SOLUTION: Tegular 8 with Mircoperforation :::: 16 LAY-IN tegular SQUARE & RECTANGULAR TILES Specification System Armstrong ceiling system Tegular 2, 8, 11F and 16 Lay-In solution with visible grid 24 mm Tile material galvanised steel sheet 0.5 mm (0.6 mm for module 750 x 750 mm) aluminium or further materials on request Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Tile details TEGULAR 2: square tile square edged with 2.5 mm drop and standard notching TEGULAR 8: square tile square edged with 8 mm drop and standard notching Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Standard modules TEGULAR 2: TEGULAR 8: TEGULAR 11F: TEGULAR 16: Grid system 600 x 600 mm 625 x 625 mm 500 x 500 mm 600 x 600 mm 675 x 675 mm 300 x 1200 mm 600 x 1200 mm 600 x 600 mm 625 x 625 mm 600 x 1200 mm 500 x 500 mm 600 x 600 mm 675 x 675 mm 750 x 750 mm Prelude 24 TLX and XL² (NB: only TLX for Tegular 2) further suspension systems on request Perimeter solution Range of standards trims in steel and aluminium plus custom bulkheads available Service integration Tegular 2 Tegular 8 Tegular 11F standard round or rectangular cut-outs plus customised options on request Tegular 16 standard perforation patterns Ultra Microperforation* Rg 0501 Hole diameter: 0.5 mm Free area: 0.64 % *only available for Tegular 2 and Tegular 11F Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% 17 :::: Acoustic Performance Colours Metal ceiling systems have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a variety of factory fitted acoustic infill options. Please contact us for more information. Standard colour RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Thermal Conductivity (λ) W/mK 50.0: Steel 0.04: Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Sustainability Armstrong is a certified EN ISO 9001:2008 Quality Assumed Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Environmental Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Acoustics Safe & Healthy % ISO 14021 Recycled content (%) Light reflectance (%) up to aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Ultra Microperforation Rg 0501 (1) up to 30 83 0.45(L) D 0.55 18 8 A1 95 scrubbable ✔ ✔ Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) ✔ ✔ Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Premium B15* up to 30 depends on perforation 0.65 C 0.60 47 21 A2-s1, d0 95 wipeable moist cloth ✔ Premium OP19* up to 30 depends on perforation 1.00 A 0.90 31 15 A2-s2, d0 95 wipeable moist cloth ✔ Humidity Fire reaction Resistance (%) up to Bioguard Cleanability paint option Scratch resistance ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. *Premium B15 and OP19 only available for Tegular 8 and Tegular 16, also some sizes of Tegular 2 ✔ :::: 18 TEGULAR 2 Detail A Tegular 2 square tile Cross-section TEGULAR 2 Quick hanger Ceiling void Tegular 2 square tile Main Runner Cross Tee Cross Tee Visible side Perimeter trim Longitudinal-section TEGULAR 2 Quick hanger Ceiling void Tegular 2 square tile Cross Tee Main Runner Visible side Perimeter trim M = module size / A = tile length / B = tile width 19 :::: TEGULAR 11F Detail A Tegular 11 F square tile Cross-section TEGULAR 11F Quick hanger Ceiling void Square tile system Tegular 11F Cross Tee Main Runner Cross Tee Visible side Perimeter trim Longitudinal-section TEGULAR 11F Quick hanger Ceiling void Square tile system Tegular 11F Perimeter trim M = module size / A = tile length / B = tile width Cross Tee Main Runner Visible side :::: 20 TEGULAR 8 Detail A Tegular 8 square tile Cross-section TEGULAR 8 Quick hanger Ceiling void Square tile system Tegular 8 Main Runner Cross Tee Cross Tee Visible side Perimeter trim Longitudinal-section TEGULAR 8 Quick hanger Ceiling void Square tile system Tegular 8 Perimeter trim M = module size / A = tile length / B = tile width Cross Tee Main Runner Visible side 21 :::: TEGULAR 16 Detail A Tegular 16 square tile Cross-section TEGULAR 16 Quick hanger Ceiling void Square tile system Tegular 16 Main Runner Cross Tee Perimeter trim Cross Tee Visible side Longitudinal-section TEGULAR 16 Quick hanger Ceiling void Square tile system Tegular 16 Perimeter trim max. M/2 M = module size / A = tile length / B = tile width Cross Tee Main Runner Visible side :::: 22 Grid system Detail A: Prelude 24 XL² grid option Not recommended with Tegular 2 tiles Detail B: Prelude 24 TLX grid option Prelude 24 Main Runner Prelude 24 Main Runner Prelude 24 XL² Cross Tee Compatible system: Prelude 24 TLX Cross Tee TLX: T2, T8, T11F, T16 XL2: T11F, T8, T16 Detail C: Suspension methods Suspension wire Suspension angle Suspension hanger Quick hanger for T-bar Bent T-bar hanger with threaded rod Nonius hanger Metal product LAY-IN Axal Vector Square & rectangular tiles BENEFITS n Can be installed with a very low void depth n Clean crisp detailing with 6mm reveal n Easy to install and remove without tools n Downwardly accessible. n Semi-concealed grid for a monolithic effect APPLICATION AREA n Used in a variety of ceiling areas: from small service rooms to large commercial office buildings and major transportation terminals. Project: Centostazioni S.p.A. (IT) :::::::: Architect: Cristian Piccolo SOLUTION: Axiom KE Canopy with Axal Vector :::: 25 LAY-IN Axal vector SQUARE & RECTANGULAR TILES Specification System Armstrong ceiling system Axal Vector, Lay-In solution with semi-concealed grid 24 mm Perimeter solution range of standards trims in steel and aluminium plus custom bulkheads available Tile material galvanised steel sheet 0.5 mm (0.6 mm for module 750 x 750 mm) (aluminium or further materials on request) Service integration standard round or rectangular cut-outs plus customized options on request Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* square tile square edged Gap solution 6 mm reveal detail, without gasket Acoustic inlay black non-woven acoustic fleece as standard. Other options available on request. Standard modules 500 x 500 mm 600 x 600 mm 300 x 600 mm 675 x 675 mm 750 x 750 mm Grid system Prelude XL2 24 * For further information about the edge detail execution of metal tiles, please see the Metal Edge Detail Execution datasheet standard perforation patterns Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% with 20 mm plain border Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% with 20 mm plain border 26 :::: Acoustic Performance COLOURS Metal ceiling systems have been tested for their acoustic performance of sound absorption. All perforated products can be supplied with a variety of factory fitted acoustic infill options. Please contact us for more information. Standard colour RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Thermal Conductivity (λ) W/mK 50.0: Steel 0.04: Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Sustainability Armstrong is a certified EN ISO 9001:2008 Quality Assumed Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Environmental Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Acoustics Safe & Healthy % ISO 14021 Recycled content (%) Light reflectance (%) up to aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Ultra Microperforation Rg 0501 (1) up to 30 83 0.45(L) D 0.55 18 8 A1 95 scrubbable ✔ ✔ Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) ✔ ✔ Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standard Perforation Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Premium B15* up to 30 depends on perforation 0.65 C 0.60 47 21 A2-s1, d0 95 wipeable moist cloth ✔ Premium OP19* up to 30 depends on perforation 1.00 A 0.90 31 15 A2-s2, d0 95 wipeable moist cloth ✔ Humidity Fire reaction Resistance (%) up to Bioguard Cleanability paint option Scratch resistance ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. *Premium B15 and OP19 only available for Tegular 8 and Tegular 16, also some sizes of Tegular 2 ✔ :::: 27 Cross-section AXAL VECTOR Quick hanger Ceiling void Axal Vector downwardly removable Cross Tee Main Runner Cross Tee Visible side Perimeter trim Longitudinal-section AXAL VECTOR Quick hanger Axal Vector Perimeter trim M = module size / A = tile length / B = tile width Ceiling void CrossTee Main Runner Visible side 28 :::: Detail A Axal Vector square tile Detail B Prelude 24 XL² grid system Prelude 24 Main Runner Prelude 24 XL² Cross Tee Detail C suspension methods Suspension wire Suspension angle Suspension hanger for T-bar Quick hanger Bent T-bar hanger with threaded rod Nonius hanger Project: Aviva Stadium (IE) :::::::: Architect: Scott Tallon Walker SOLUTION: Axal Vector plain Metal product R-L 201 system Square & rectangular tiles 31 :::: R-L 201 SQUARE & RECTANGULAR TILES BENEFITS n Diversity of design and application n Easily assembled and fully demountable n Cost effective ceiling solution n Panels are easily lifted out by hand, allowing full and easy access to the ceiling void n Slim bandraster effect of 38 mm width APPLICATION AREA n Used in a variety of ceiling areas: large commercial office buildings and major transportation terminals. Specification System Armstrong ceiling system R-L 201 Lay-In solution with visible grid, suspension height min. 105 mm Panel material Galvanised steel sheet panel width up to 400 mm 0.6 mm panel width from 401 mm 0.7 mm (aluminium or other materials on request) Coating RAL 9010 pure white post-coated powder painted visible surface, other RAL or NCS colours on request Execution* Rectangular panel square edged long sides CA / DA (40 - 55 mm) short sides E3 / F3 (18 mm) Gap solution 3 mm gap with black gasket on one long side, optional available without gasket Acoustic inlay Black non-woven acoustic fleece as standard. Other options available on request. Configurable dimensions Panel length (A) 600 - 3000 mm Panel width (B) 275 - 1350 mm Grid system U-profile + L-profile Perimeter solution Range of standard trims in steel and aluminium plus custom bulkheads available Service integration Standard round or rectangular cut-outs plus customised options on request Special capabilities - trapezoidal panel solution - can be combined with R-H 200 or other Armstrong products * For further information about the edge detail execution of metal panels, please see the Metal Edge Detail Execution datasheet standard perforation patterns Extra Microperforation Rg 0701 Hole diameter: 0.7 mm Free area: 1.5 % Microperforation Rd 1522 Hole diameter: 1.5 mm Open area: 22% Standard Perforation Rg 2516 Hole diameter: 2.5 mm Open area: 16% :::: 32 Acoustic Performance Colour Metal ceiling systems have been tested for their acoustic performance in terms of sound absorption, sound attenuation and sound reduction. These performance values will depend upon the perforation and the acoustic infill. Please contact us for more information on the available factory fitted acoustic options. Standard colours RAL 9010 Global White RAL 9006 RAL 9007 20% gloss 12% gloss 30% gloss 30% gloss Thermal Conductivity (λ) W/mK 50.0 : Steel 0.04 : Acoustic fleece RAL 9010 Global White RAL 9006 RAL 9007 Special colours Other RAL and NCS colours available on request Humidity Exposure Up to 95% RH (for short term exposure). Quality Standard Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All Armstrong ceiling and grid systems are manufactured to the relevant tolerances and quality standards appropriate to material. Where differences exist between this and any expressed or implied architectural specificaitons or requirements then Armstrong’s manufacturing standards will prevail unless stated otherwise. Services Integration Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment. Cleaning Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners of the painted surface is not recommended. Sustainability Environmental Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: ISO 14001:2004 + Cor. 1:2009 Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). Acoustics Safe & Healthy % ISO 14021 Recycled content (%) Light reflectance (%) aw Sound absorption class NRC up to Dncw / Dnfw (dB) up to Rw (dB) up to Fire reaction Humidity Resistance (%) up to Cleanability up to Extra Microperforation Rg 0701 (2) up to 30 80 0.55(L) D 0.65 21 10 A2-s2, d0 95 wipeable moist cloth (3) Microperforation Rd 1522 (2) up to 30 65 0.70 C 0.70 16 6 A2-s2, d0 95 wipeable moist cloth (3) ✔ Standardperforated Rg 2516 (2) up to 30 70 0.75(L) C 0.80 18 8 A2-s2, d0 95 wipeable moist cloth (3) ✔ Plain / Unperforated (1) up to 30 85 0.10(L) Not Classified 0.10 44 19 A1 95 scrubbable Premium B15 up to 30 depends on perforation 0.65 C 0.60 47 21 A2-s1, d0 95 wipeable moist cloth ✔ Premium OP19 up to 30 depends on perforation 1.00 A 0.90 31 15 A2-s2, d0 95 wipeable moist cloth ✔ Bioguard paint option Scratch resistance ✔ ✔ ✔ (1) RAL 9010 colour, without acoustic inlay. (2) RAL 9010 colour, with black acoustic fleece glued on rear. (3) Wipeable moist cloth for preforated tiles with fleece. Scrubbable for plain tiles or perforated tiles without fleece. ✔ 33 :::: Cross-section Expansion bolt M6 Ceiling Void Threaded rod M6 Plug-in clip Wall anchor Clamping bracket U-profile Hanger for L-profile L-profile Cut panel Perimeter trim R-L 201 rectangular panel Visible side Longitudinal-section Expansion bolt M6 Threaded rod M6 Ceiling Void Clamping bracket U-profile L-profile Cut panel R-L 201 rectangular panel Perimeter trim M = module size / A = panel length / B = panel width Item No. Designation Item No. Designation BPM 300100 U-profile BPM 215440 L-profile BPM 300119 Connector for U-profile BPM 300343 Connector for L-profile BPM 300120 Plug-in clip BPM 300307 Hanger for L-profile BPM 300140 Wall anchor BPM 311303 Hexagonal bolt M6 x 16 mm BPM 300121 Clamping bracket BPM 311103 Hexagonal nut M6 BPM 311111 Expansion bolt M6 x 30 mm BPM 311305 Washer M6 18 x 1.6 mm BPM 311099 Threaded rod M6 x 1‘000 mm Visible side :::: 34 Detail A R-L 201 panel Detail B Grid system Hexagonal bolt M6 Hexagonal nut M6 Washer M6 Fall 3 Fall A Expansion bolt M6 Threaded rod M6 Clamping bracket Plug-in clip Fall A Wall anchor Fall 3 Connector for U-profile Connector for L-profile U-profile Plug-in clip Hanger for L-profile Detail C L-profile Suspension methods Clamping bracket Hanger for U-profile Combi Nonius hanger with Nonios top-part Combi Nonius hanger with eye wire Belgium & Luxembourg Armstrong Building Products B.V. Postbus 3803 4800 DV Breda Netherlands Tel.: +32 02 223 00 72 Fax: +31 (0) 76 521 04 07 e-mail: benelux-info@armstrong.com www.armstrongplafonds.be Germany & Switzerland Armstrong Building Products Kundenservice Office Building Quadrium Claudius Prinsenlaan 126 4818 CP Breda Netherlands Tel.: +49 (0) 251 7603 210 Fax: +49 (0) 251 7603 593 e-mail: deutsche-info@armstrong.com www.armstrongdecken.de www.armstrong-decken.at www.armstrong.ch Firmensitz Armstrong Building Products GmbH Robert-Bosch-Str. 10 48153 Münster Germany Armstrong Metalldecken AG Breitfeldstrasse 8 9015 St. Gallen Switzerland Tel.: +41 (0) 71 313 63 63 Fax: +41 (0) 71 313 64 00 e-mail: gema@armstrong.com www.armstrong.ch www.gema.biz Zentralschweiz Armstrong Metalldecken AG Büro / Lager Zentralschweiz Grossweid 9 6026 Rain Switzerland Tel.: +41 (0) 41 921 63 63 Fax: +41 (0) 41 921 63 80 e-mail: gema@armstrong.com www.armstrong.ch www.gema.biz Armstrong Plafonds Métalliques SA Bureau et Dépôt Suisse Romande Avenue de Châtelaine 87 1219 Châtelaine Suisse Tel.: +41 (0) 22 731 60 70 Fax: +41 (0) 22 731 60 74 e-mail: gema@armstrong.com www.armstrong.ch www.gema.biz Austria Armstrong Metalldecken GmbH Bundesstrasse 70 6830 Rankweil Austria Tel.: +43 (0) 55 22 34 44-0 Fax: +43 (0) 55 22 34 44-8 e-mail: gema@armstrong-decken.at www.armstrong-decken.at www.gema.biz Armstrong Metalldecken GmbH Messendorferstrasse 6 8041 Graz Austria Tel.: +43 (0) 316 471 584 Fax: +43 (0) 316 471 584-10 e-mail: gema@armstrong-decken.at www.armstrong-decken.at www.gema.biz Spain & Portugal Armstrong Building Products SAS Immeuble Paryseine 3, allee de la Seine 94854 Ivry-sur-Seine Cedex France Phone: + 34 91 642 04 99 info-espana@armstrong.com www.armstrongtechos.es France Armstrong Building Products SAS Bureaux Commerciaux France Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-Seine France Tel.: 0800 41 36 43 Fax: +33 1 45 21 04 11 e-mail: info-France@armstrong.com www.armstrongplafonds.fr Siège social Armstrong Building Products SAS 67 rue de Salins – CS 20089 25302 Pontarlier Cedex France Italy & Greece Armstrong Building Products Uffi cio Commerciale Italia Immeuble Paryseine 3 Allée de la Seine 94854 Ivry-sur-Seine France Tel.: +39 02 66 22 76 50 Fax: +39 02 66 20 14 27 e-mail: info-italia@armstrong.com www.armstrongsoffitti.it Netherlands Armstrong Building Products B.V. Postbus 3803 4800 DV Breda Netherlands Tel.: (+31) 076 523 02 00 Fax: (+31) 076 521 04 07 e-mail: benelux-info@armstrong.com www.armstrongceilings.nl United Kingdom Armstrong World Industries Ltd Building Products Division Armstrong House 38 Market Square Uxbridge UB8 1NG United Kingdom Tel.: 0800 371 849 Fax: +44 1895 274287 e-mail: sales-support@armstrong.com www.armstrongceilings.co.uk Republic of Ireland Armstrong World Industries Ltd. 108 Greenlea Road Terenure Co Dublin 6W Ireland Tel.: 1800 409002 Tel.: (+353) 1 499 1701 Fax: (+353) 1 490 7061 e-mail: sales-support@armstrong.com www.armstrongceilings.ie Central Europe North (DK/EE/FIN/IS/LT/LV/N/PL/S) Armstrong Building Products BV Sp. z o.o. Oddział w Polsce ul. Domaniewska 37 02-672 Warszawa Poland Tel.: (+48) 22 337 86 10/ 86 11 Fax: (+48) 22 337 86 12 e-mail: service-ce@armstrong.com Latvia: www.armstrong.lv Lithuania: www.armstrong.lt Norway: www.armstrong.no Poland: www.armstrongsufity.pl Sweden: www.armstrong.se Central Europe South (AL/BA/BG/CZ/HR/HU/KO/ MD/ME/MK/RO/RS/SK/SI) Armstrong Building Products Lighthouse building, Jankovcova 1569/2c, 170 00 Praha 7, Czech Republic Tel.: +420 725 477 588 e-mail: service-ce@armstrong.com Czech Republic: www.armstrong.cz Hungary: www.armstrong.co.hu Romania: www.armstrong.ro Serbia: www.armstrong.rs Slovakia: www.armstrong.sk Slovenia: www.armstrong.si www.armstrongceilings.eu Eastern Europe CIS Armstrong Moscow GmbH Mosfi lmovskaya Street 38A, Moscow 119285, Russian Federation Tel.: +7 (495) 258 5100 Fax: + 7 (495) 258 5103 e-mail: info-cis@armstrong.com Russian Federation: www.armstrongceilings.ru MIDDLE EAST / AFRICA / TURKEY Armstrong World Industries Ltd Africa Middle East Turkey Division Armstrong House 38 Market Square Uxbridge UB8 1NG Tel.: +44 01895 202097 Fax: +44 01895 272928 e-mail: sales-support@armstrong.com www.armstrong.eu Israël: www.armstrong.co.il South Africa: www.armstrong-ceilings.co.za Middle East Regional Office, Dubai, UAE & French Speaking Africa Offi ce No. 2003, 20th Floor Gold Crest Executive Tower Jumeirah Lakes Towers P.O. Box 73831 Dubai, United Arab Emirates Tel.: +971 4 453 4545 Fax: +971 4 453 4546 info-me@armstrong.com www.armstrong.ae Turkey Armstrong Europa GmbH Mimar Sinan Mah. Mimar Sinan Cad. No: 35/2 Cekmekoy Istanbul Turkey Gsm: +90 542 772 49 22 Gsm: +90 544 293 5931 www.armstrong.com.tr etulpar@armstrong.com 10/2015 - PAS1205 - Armstrong Building Products - RCS Besançon B 784 131 575 Printed on chlorine free paper. Western Europe