LabVIEW: Instrumentation Lab and Industry MAESC 2004 Jerome Mills, Eugene Fayne, Patrick Ireland, Joan McGrory, and John Ventura May 12, 2004 NI ELVIS Overview Computer Running LabView DAQ Device 6868-Pin Cable Prototyping Board Benchtop Workstation 1 Instrument Launcher Frequency Analysis Channel B Channel A 2 Function Generator Oscilloscope 3 Function Generator-Advance Mode Bode Plot 4 Background Information on Gyrus ENT • • • • Company is located in Bartlett, TN. Manufactures Ear, Nose, and Throat surgical devices. Employ 180 people. Produce about 60,000 Hemostatix blades per year. About the Hemostatix Blade • Scalpel used in many surgeries today. • Heats up to 300 C°. • Cauterizes tissue resulting in lower blood loss. 5 Existing Problems • • • • Current process is slow. Can result in complaints. Faulty blades reach doctors. Measuring 1800 blades requires 20 hours. • 2 employees perform this operation. • Employees have been sent to hospital. Possible Solutions • Hire more employees to perform the measurements. • Design and implement a data acquisition system. • Design a safer way to measure resistance. 6 Solution • Use a data acquisition system developed by National Instruments (www.ni.com). • Use software and hardware sold by NI. What is LabView? •LabView is a graphical programming language. •LabView programs, "virtual instruments" (VI’s), are created using icons instead of text-based code. 7 • Measures 12 blades at a time (horizontal fixture). • Results have a percent difference of 0.62%. • Based on the range, an LED will light for a pass/fail test. What does the hardware do? 1) Data Acquisition Card (PCI) 2) SCXISCXI-1000 3) SCXISCXI-1127 4) SCXISCXI-1331 8 Inside the 1331 terminal block The Kelvin Bridge Unknown resistance • A 4-wire measurement results in more accurate results. • Use Ohms Law to solve for the resistance. • R = V/I Known current Measured Voltage 9 The manufacturing process Horizontal position Thick film process Vertical position Data Acquisition Measurements NonNon-Stick Coating Process Data Acquisition Measurements Custom Horizontal Hardware • Using current blade trays to introduce connections to computer. 10 Custom Vertical Hardware Problems Encountered • Couldn’t acquire measurements due to improper installation of software. • Fragile leads. • Contact problems between the blade and pin. 11 Costs • • • • • • LabView Software 1331 modules SCXI Chassis 1331 Terminal Blocks Cable Assembly DAQ card (PCI) • • • • • • $1,995 3* $995 $695 6* $180 $260 $295 • $7,310 • Total Cost Savings • Gyrus makes 60,000 blades per year in 33 work orders. • 18 manual hours saved per work order. • 594 manual hours saved per year. • 594*$15 per hour = $8,911. • Projected to pay itself off in under one year. • Increased productivity resulting in fewer backorders. 12 Questions? 13