LANSDOWNE HS FUNCTIONAL ASSESSMENT GYM AREA MEASURED AREA HEIGHT PANIC HARDWARE LOCKER ROOM AUXILIARY GYM AUX GYM MEASURED AREA AUX GYM HEIGHT CONDITION COMMENTS CAFETERIA AREA MEASURED AREA HEIGHT PANIC HARDWARE KITCHEN CONDITION COMMENTS MEDIA CENTER AREA MEASURED AREA HEIGHT PANIC HARDWARE ADA CASEWORK CONDITION COMMENTS 12928 11220 22 PARTIAL YES NO 3 clerestory lets in good diffused daylight, ok acoustics 8464 7088 11 NO FULL 3 little daylight, open space with good adjacency but no visual access to serving line, odd odor 6040 4673 11.7 NO NON‐ADA 3 good daylight, open space, no adjacent computer lab, AUDITORIUM AREA MEASURED AREA HEIGHT PANIC HARDWARE STAGE STAGE AREA CONDITION COMMENTS CLASSROOMS MEASURED AREA (TYP) HEIGHT (TYP) ADA CASEWORK CONDITION COMMENTS ADDITIONAL SPACES CONFERENCE ROOMS CONF RM AREA HEALTH SUITE AREA GUIDANCE SUITE AREA SPECIALTY SPACES SPECIAL EDUCATION SPECIAL ED # OF ROOMS CTE PROGRAMS SPECIALTY PROGRAMS OPEN SPACE CLASSROOMS RELOCATABLES RELOC_COMMENTS 15403 10020 25.8 YES NO 982 2 seating capacity is ok, but rear seating configuration is inefficient 689 10.3 ADA ACCESSIBLE 3 good daylight, small rooms, lack of casework, bland; science‐ 1268 sf, 9.2 ft no ada lab stations 2 296 102 193 Activity Room 4859 SF YES 5 FINE ARTS HEALTH PROFESSIONS SCIENCE FINANCE ART MUSIC SCIENCE NO 1 unused ADA FACILITIES SINKS TOILETS CLEARANCES DRINKING FOUNTAINS STAIRS STAIR WIDTH RAMPS ELEVATOR COUNT DOOR CLEARANCE DOOR HARDWARE CORRIDOR WIDTH CORRIDOR HEIGHT CORRIDOR PROTRUSIONS HEALTH SUITE DEAD END CORRIDORS BUILDING ENTRANCE EXITS GYM AUDITORIUM CAFETERIA MEDIA CENTER NO NO NO NO YES 5.6 N/A PARTIAL PARTIAL 10 9.5 ELEVATION CHANGES PIPES DISPLAY CASES YES NO ELEVATION CHANGES 6 12 8 2 OVERALL CONDITION OVERALL NOTES 2 elevation changes in many areas with no ramp access, core spaces have good locations, with dedicated lobbies for each; multiple access points could be a security concern, non ada gym entrance SITE NOTES Topography creates elaborate site entry and exit, site at busy intersection, play fields are very distant from building, large pond adjacent to site. Good visual access to admin, but entry is somewhat hidden, multiple entry points take away from centrality, hierarchy. LANSDOWNE HS PHYSICAL ASSESSMENT LOCATION AUDITORIUM ASSEMBLY TYPE CEILING AUDITORIUM CORRIDORS SCIENCE ROOM CLASSROOMS MEDIA CENTER CAFETERIA CEILING CEILING CEILING CEILING CEILING CEILING GYM CEILING STOREFRONT EXTER BLDG EXTERIOR OPENING EXTERIOR OPENING EXTERIOR OPENING EXTERIOR WALL EXTER BLDG STOREFRONT LOUVER MATERIAL FINISH GYP BD ALUM COMMENTS 3 large water stain, acoustic treatment in some areas 1 in rear seating area, patching 1 patching in many areas 2 bowing 2 1 patching everywhere 1 leaking, staining, bowing, bulkhead denotes entry from main space 3 acoustic panels hung along depths of concrete beams 2 breezeway to cafeteria and gym wing, in poor shape 4 at main entrance ALUM 3 ACT ACT ACT ACT ACT ACT EXPOSED STRUCTURE ALUM INSULATED METAL PANEL BRICK METAL PANEL EXTERIOR WALL ALUM INSULATED METAL PANEL EXTER BLDG EXTERIOR WALL METAL CERAMIC TILE SITE WALLS AUDITORIUM AUDITORIUM STAGE CORRIDORS STAIRS SCIENCE ROOM CLASSROOMS MEDIA CENTER CAFETERIA GYM ADMIN CONCRETE CONCRETE CONCRETE WOOD CONCRETE STEEL CONCRETE CONCRETE CONCRETE CONCRETE WOOD HM AUDITORIUM CORRIDORS EXTERIOR WALL FLOOR FLOOR FLOOR FLOOR FLOOR FLOOR FLOOR FLOOR FLOOR FLOOR INTERIOR OPENING INTERIOR OPENING INTERIOR OPENING INTERIOR OPENING INTERIOR OPENING INTERIOR WALL INTERIOR WALL CMU CMU GYP BD CERAMIC TILE STAIRS SCIENCE ROOM CLASSROOMS MEDIA CENTER INTERIOR WALL INTERIOR WALL INTERIOR WALL INTERIOR WALL CMU CMU CMU CERAMIC TILE PAINT GLAZED BLOCK GYP BD CLASSROOMS MEDIA CENTER CAFETERIA GYM HM VCT VAT TERRAZZO TERRAZZO VCT VAT CARPET TERRAZZO WOOD ALUM CONDITION 4 corrugated metal wrap for upper half of auditorium 2 window bay system, some panels have been replaced, others in horrible shape, oil canning pamels 2 cracking tiles, storefront in poor shape at cafeteria 2 1 2 4 2 2 4 2 3 2 3 3 patching, cracking at seams, damaged, raw in rear seating area, patching worn, cracking terrazzo treads, terr tile landing steel pan stair furniture marks, cracking significant wear, poor thresholds 4 wired glass lites HM 3 provide views into corridor and other served spaces within 3 doors with transom band at serving line CONCRETE 1 broken panes in gym clerestories 3 some wear, wood panelling along stage 3 ceramic tile walls jut out between locker bays, worn at base 3 side walls have typ corridor ct, rear wall has 2x2 4 2 glazed block in bad shape 3 mostly storefront and built in casework LOCATION CAFETERIA GYM CANOPY ASSEMBLY TYPE MATERIAL INTERIOR WALL INTERIOR WALL CMU ROOF STEEL SOFFIT ROOF CONCRETE GENERAL NOTES: leaking is a major problem nearly all ceiling are in need of replacement poor finishes in most areas raw concrete floors in art wing OVERALL PHYSICAL CONDITION: 1 FINISH CERAMIC TILE GLAZED BLOCK CONDITION COMMENTS 2 dirty grout, gyp board partition at serving line 3 stack bond, some patching around bleachers 3 bus canopy at main entry, stone panel and square tube column supports 2 water damage at main entry LANSDOWNE HS BUILDING SYSTEMS ASSESSMENT MECHANICAL AUTOMATIC TEMPERATURE CONTROLS ATC MANUFACTURER JOHNSON CONTROLS ATC SYSTEM TYPE D.D.C. ATC COMPRESSOR YES ATC COMPRESSOR CONDITION 4 CONDITION 4 NOTES ‐ The 1963 portion of the building has pneumatic controls and the condition rating is one. The 1998 Addition has DDC controlls and the condition rating is as indicated above. HEATING HEATING SYSTEM DUAL TEMP IN 1998 ADDITION, 2 PIPE HEATING ONLY IN ORIGINAL 1963 BUILDING. PIPE INSULATION CONDITION 1 HOT WATER PIPE CONDITION 1 VALVING CONDITION 1 CHEMICAL TREATMENT CONDITION 2 CHEMICAL TREATMENT? YES BOILER FUEL TYPE GAS OVERALL CONDITION 2 HEATING NOTES ‐ No Heating System Chemical treatment in 1963 original building Boiler room. ‐ Piping, Valving and pipe insulation condition values are for the 1963 building system. AHU NOTES ‐ The majority of the split system condensing units serving unit ventilators in the 1998 Addition's classrooms are disconnected. COOLING MAIN SYSTEM TYPE DUAL TEMP PIPE INSULATION CONDITION 3 CONDENSER CONDITION 3 VALVING CONDITION 3 CHILLER CONDITION 3 CHEMICAL TREATMENT CONDITION 3 CHEMICAL TREATMENT? YES OVERALL CONDITION 3 NOTES PLUMBING/FP FIRE PROTECTION BUILDING COVERAGE SYSTEM CONDITION FIRE PUMP? FIRE PUMP TYPE FIRE PUMP CONDITION SYSTEM TYPE SYSTEM CONDITION STANDPIPE STANDPIPE CONDITION NOTES OVERALL CONDITION DOMESTIC WATER INCOMING DOMESTIC WATER CITY/COUNTY WATER BOOSTER PUMP BOOSTER MANUFACTURER DATE BOOSTER CONDITION DOM WATER HEATERS DOM WATER COND DW FUEL SOURCE BFP BFP CONDITION PLUMBING FIXTURES PIPING CONDITION PIPING INSULATION CONDITION VALVING CONDITION OVERALL CONDITION PLUMBING SYSTEM NOTES no sprinklers DOMESTIC ONLY PUBLIC NO VERT. TANK 4 GAS NO 2 4 3 4 3 ELECTRICAL SERVICE MANUFACTURER VOLTAGE AMPERAGE MAINS MAIN DISC QTY COMMENTS YEAR INSTALLED CONDITION NOTES DISTIBUTION TRANSFORMERS PANEL BOARDS MOTOR CONTROL CENTER CONDITION NOTES GENERATOR MANUFACTURER FUEL TYPE LOCATION RATING KW COMMENTS CONDITION NOTES LIGHTING CONDITION NOTES SQUARE D 277/480V, 3Ø 3000A CKT BRKR 1 DAMAGE LACKS CODE CLEARANCE 2 Panel covers appear to be corroded. Please consider upgrading this SWBD to accommodate future development and to ensure the safety of the facility's equipment. AVERAGE CONDITION CIRCUIT BREAKERS IN CORRIDORS ACCESSIBLE TO STUDENTS DAMAGED MISSING COVERS CIRCUIT BREAKERS AVERAGE CONDITION 3 Throughout bldg power distribution is conducted with federal pacific panels. Please consider upgrading these panels to ensure the safety of the facility's equipment and property. Also, please consider replacing panels without covers to ensure the safety of equipment and occupants in bldg. N/A FIRE ALARM MANUFACTURER TYPE ALARM MOTIFICATION COMMENTS CONDITION NOTES SECURITY ACCESS CONTROL DEVICES CONDITION NOTES CCTV CAMERAS RECORDING CONDITION NOTES IT/DATA CLASSROOMS CONDITION NOTES EDWARDS SYSTEM TECH ADDRESSABLE PULL STATIONS SMOKE DETECTORS SPEAKERS/VOICE STROBES (ADA) FULL COVERAGE 5 MAIN ENTRY INTERCOM MAIN ENTRY DOOR RELEASE CARD READERS MOTION SENSORS 3 Motion sensors are not in 2nd floor classrooms. Please consider adding these systems to ensure the safety of property. BOTH YES 5 HARDWIRED NETWORK OUTLETS MEETS MSDE (3 PER RM) SMART BOARDS 3 Some classrooms have smart boards, while most every other classroom does not. LANSDOWNE HS MEP EQUIPMENT CATEGORY COOLING HEATING HEATING HEATING HEATING AIR HANDLING UNITS AIR HANDLING UNITS ROOM TYPE/EQUIP TYPE WINDOW AC BOILERS BOILER CIRCULATION HEATING WATER PUMPS BASEBOARDS ADMIN GYM AIR HANDLING UNITS AUX. GYM AIR HANDLING UNITS CAFETERIA AIR HANDLING UNITS ADDITION AIR HANDLING UNITS LOCKER ROOM AIR HANDLING UNITS CLASSROOMS AIR HANDLING UNITS AIR HANDLING UNITS AIR HANDLING UNITS AIR HANDLING UNITS CLASSROOMS CLASSROOMS COMPUTER ROOM CLASSROOMS AIR HANDLING UNITS AUDITORIUM TYPE QUANTITY HYDRONIC IN‐LINE BASE MOUNTED CONDITION 2 2 6 0 WINDOW AC UNITS HEATING & VENTILATION UNIT HEATING & VENTILATION UNIT HEATING & VENTILATION UNIT HEATING & VENTILATION UNIT HEATING & VENTILATION UNIT HEATING & VENTILATION UNIT WINDOW AC UNITS SELF CONTAINED SPLIT SYSTEM AHU HEATING & VENTILATION UNIT HEATING & VENTILATION UNIT 5 4 4 2 2 3 2 2 3 1 2 1 3 3 2 0 2 0 12 4 3 3 5 4 4 3 LANSDOWNE HS LIGHT FIXTURES ROOM TYPE CAFETERIA KITCHEN GYM CLASSROOMS LIBRARY CORRIDORS COMPUTER ROOM AUDITORIUM HALL CLASSROOMS CORRIDORS HEALTH SUITE OFFICES STAIRS ADMIN CONFERENCE ROOMS EXTER BLDG EXTER CANOPY PARKING LOT FIXTURE TYPE RECESSED RECESSED SUSPENDED SUSPENDED RECESSED RECESSED RECESSED RECESSED RECESSED RECESSED RECESSED RECESSED SURFACE MTD RECESSED SUSPENDED SURFACE MTD SURFACE MTD POLE LIGHTS LAMPING T8/T12 T8/T12 METAL HALIDE T8/T12 T8/T12 T8/T12 T8 FLUOR T8 FLUOR T8/T12 T8 FLUOR T8/T12 T8/T12 T8/T12 T8/T12 HID HID HPS CONDITION 1 3 3 1 2 3 5 1 5 1 3 3 3 2 1 2 3 3 COMMENTS PAST LIFE EXPECTANCY AVERAGE CONDITION AVERAGE CONDITION PAST LIFE EXPECTANCY PAST LIFE EXPECTANCY AVERAGE CONDITION GOOD CONDITION NONE PRESENT GOOD CONDITION POOR CONDITION AVERAGE CONDITION AVERAGE CONDITION AVERAGE CONDITION POOR CONDITION PAST LIFE EXPECTANCY PAST LIFE EXPECTANCY AVERAGE CONDITION AVERAGE CONDITION