PDU - GomSpace

advertisement
NanoPower
P60 PDU-200
Datasheet
Power Distribution Unit daughterboard for the P60 system
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
1 Table of contents
1
TABLE OF CONTENTS ............................................................................................................... 2
2
CHANGE LOG ............................................................................................................................. 3
3
SYSTEM OVERVIEW ................................................................................................................... 4
3.1 HIGHLIGHTED FEATURES .................................................................................................... 4
3.2 BLOCK DIAGRAM ................................................................................................................ 5
4
CONNECTOR PINOUT ................................................................................................................ 6
4.1 TFM OUTPUT ..................................................................................................................... 6
4.2 FPC DEBUG ....................................................................................................................... 7
5
ABSOLUTE MAXIMUM RATINGS .............................................................................................. 8
6
ELECTRICAL CHARACTERISTICS ............................................................................................ 8
7
PHYSICAL LAYOUT .................................................................................................................... 9
© 2016 Gomspace Aps
2
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
2 Change log
Date
8-1-2015
Revision
1.0
© 2016 Gomspace Aps
Author
KLK/HPM
Description
First release
3
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
3 System Overview
The P60 PDU-200 (Power Distribution Unit) is a GomSpace daughterboard to be used with the P60
Dock. It contains 9 output channels with configurable voltage output.
Figure 1 CAD drawing of a motherboard with 4 daughtersboards with shields
3.1 Highlighted Features
P60 PDU-200 Module
- 9 switchable, latch-up, overcurrent protected outputs
- Outputs available in a high-current rated discreet connector
- Outputs are routed via P60 Dock to the PC104 stack
- 3 buck converters per module for regulated voltages below the battery voltage.
- Configurable output voltages per module of 3.3 V, 5 V or 8 V
o 12 V, 18 V, 24 V possible for one regulator and two channels.
- Protected 1 A - 2 A programmable current limit on outputs
- Current and voltage measurements on each output channel
- Detection and logging of overcurrent events
- Synchronized out-of-phase converters for low EMI operation
- Spread Spectrum Frequency Modulation
- Mass: 57 g with shield
Note that the total power conversion is limited by thermal considerations. Hence installation
hardware and operating voltages is indirectly a limiting factor – in general the higher voltage the
higher power.
© 2016 Gomspace Aps
4
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
3.2 Block Diagram
The PDU module contains 3 buck converters that can be connected to each of the 9 output
channels. HW configuration during production fixes each output to a specific converter and sets the
voltage of each converter. An output channel can also be configured to unregulated battery voltage.
All 9 outputs are available in the motherboard stack connector, and only 6 of the channels are
available in the TFM connector (together with a few communication channels).
To
motherboard
T
3x Buck
Converter
HW Config Matrix
9x LUP
Switched Output
MCU
Measurement
and Control
T
P60 PDU-200
Module
6x to TFM
connector
Temperature Measurement
9x to
stack connector
Figure 2 P60 PDU-200 block diagram
© 2016 Gomspace Aps
5
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
4 Connector Pinout
4.1 TFM Output
Note that the polarization key is located next to pin 30.
Pin
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
Description
Output 1
Output 1
SDA
Output 0
Output 2
SDA
Output 3
VBAT
VBAT
Output 5
VCC-internal
CANH
Output 6
Output 6
CANH
© 2016 Gomspace Aps
Pin
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
Description
GND
GND
SCL
GND
GND
SCL
GND
GND
GND
GND
GND
CANL
GND
GND
CANL
6
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
4.2 FPC Debug
Manual programming and test connector
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Description
GND
VCC
RESET_NOT
JTAG_TDI
JTAG_TMS
JTAG_TCK
JTAG_TDO
GND
VCC
UART_RX (GOSH)
UART_TX (GOSH)
Not connected
Not connected
Not connected
Not connected
Not connected
Not connected
GND
© 2016 Gomspace Aps
7
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
5 Absolute Maximum Ratings
Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to
the P60. Exposure to absolute maximum rating conditions for extended periods may affect the
reliability.
Symbol
Tamb
Vio
Description
Operating Temperature
Voltage on I2C/USART pins
Min.
-40 °C
-0.1
Max.
+85 °C
3.4
Unit
°C
V
6 Electrical Characteristics
Parameter
Battery
- Voltage
- Current, charge
- Current, discharge
PV inputs
- Voltage
Condition
Battery connection
8 volt
16 volt
32 volt
Min.
Typ.
Max.
Unit
6.0
12.0
24.0
7.4
14.9
29.6
8.4
16.80
33.6
V
V
V
4
A
A
25.0
V
2.0
A
(Depends on battery configuration)
Overcurrent protection threshold
Photo-voltaic inputs
4
4.5
- Current, charge
16.0
0.0
+ 5 V Stack connector
- Voltage
- Current, cont.
5 V regulated output
4.89
0.005
5.20
Total current H2-25 and H2-26
5.35
1.00
V
A
+ 3.3 V Stack connector
- Voltage
- Current, cont.
3.3 V regulated output
From -40 °C to +85 °C
Total current H2-27 and H2-29
3.20
0.00
3.29
3.39
0.50
V
A
V_BAT
- Voltage
- Current, cont.
Raw battery voltage
(Depends on battery configuration)
H2-45 and H2-46
Power consumption
Power consumed by NanoPower,
not including daughterboards
Current consumed with separation
switch OFF
Off current
© 2016 Gomspace Aps
1.0
A
8
P60 PDU-200 datasheet
8 March 2016
gs-ds-nanopower-p60-pdu200-1.0
7 Physical Layout
The PDU PCB top under the shield has two connectors at the right edge and at the bottom left
corner. Middle left is a MCU and a FRAM. Top left is a LED. Middle right are three buck converters.
Figure 3 PDU module top
The bottom side has two FSI connectors to the left, Buck converters middle. Two ADC right side
middle and bottom left.
Figure 4 PDU module bottom
© 2016 Gomspace Aps
9
Download