Air Conditioning at its best Product range 2006/2007 Split and Multi Split Systems Heat Pump Systems VRF Systems Close Control Systems Ventilation Systems with Heat Recovery Roof Top Systems Dehumidifier M Series Mr. Slim City Multi Lossnay Dehumidifier Air conditioning at its best Mitsubishi Electric creates a convenient climate wherever people live and work. The fact that this is achieved with the highest technical standards is well-known to end-consumers, installers and dealers. Air conditioning products and solutions from Mitsubishi Electric are world-famous and have enjoyed an outstanding reputation for many decades. Mitsubishi Electric stands for both experience and innovation: for over 50 years our company has been repeatedly setting new standards in air conditioning technology and has established itself as one of the most important manufacturers world-wide. Our self-obligation and motivation is summed up in our motto 'Changes for the Better'. We therefore conduct intensive research and development work to make our products even more efficient and thus always stay one step ahead of the market trend. Regular controls guarantee a consistently high quality of our products. 2 쎱 Efficient The Mitsubishi Electric split and multi split systems use energy very sensibly end efficiently due to inverter technology and new refrigerant. The user is able to control each indoor unit separately to set a customized temperature. WEEE The new law valid from March 2006 on does not regard split air conditioners. However Mitsubishi Electric takes care of waste management for the dehumidifier and small Lossnay units LGH40ES-E / VL100. Compact and space-saving The light and compact outdoor units can be installed easily at the wall or on the top of buildings. In opposition to air-cooled chillers which are associated with specially required installation sites the Mitsubishi Electric systems ensure a flexible planning and dimensioning. Refrigerant R410A Mitsubishi Electric has converted all systems to the environment-friendly refrigerant R410A. Thus the COP values have been improved significantly. 쎱 Expandable The environment-friendly systems can be installed with minimal amount of work. In case of an increased power requirement, a subsequent extension of the system is possible. 쎱 Economical Especially the M Series, constructed for consumer applications, achieved highest energy efficiency. The majority of the range receives the best energy efficiency rank A for very low consumption (scale A-G). 쎱 RATING CONDITIONS MITSUBISHI ELECTRIC AIR CONDITION SYSTEMS Cooling: indoor 27° C (DB) / 19° C (WB) outdoor 35° C (DB) / 24° C (WB) (outdoor WR2, WY: cooling water temperature 30° C) Heating: indoor 20° C (DB) outdoor 7° C (DB) / 6° C (WB) (outdoor WR2, WY: cooling water temperature 20° C) Refrigerant piping length 5 m / 7.5*m (one way), 욼H = 0 m. Noise level measured in anechoic chamber at a position of 1 m in front of the outdoor unit. For indoor units kindly refer to the values given in the following tables. * for PUH-P200/250MYA and City Multi 쎱 쎱 Sensitive cooling capacity This catalogues states the total capacities. For an installation of Mr. Slim or City Multi indoor units in technical rooms, a planning considering the sensitive cooling capacity is necessary. The sensitive capacities are specified in the data books. 쎱 Model identification in kW The model names include the cooling capacity code quoted in kW (previously in BTU/h). Furthermore the multi split outdoor units includes the number of maximum connectable indoor units. 쎱 Single Split Indoor Unit MSZ-GA25VA G: Series: G = Standard, F = Deluxe A: Generation: A = Basic model, B,C,D ... Successor 25: Cooling capacity = 2,5 kW V: 230V, 50 Hz A: R410A and new A-Control Multi Split Outdoor Unit MXZ-3A54VA 3: Number of max. indoor units A: Generation: A = Basic model, B,C,D ... Successor 54: Cooling capacity = 5,4 kW V: 230V, 50 Hz A: R410A and new A-Control 3 Content Mr. Slim Series M Series The air conditioners of the M Series are designed for small and mediumsized rooms. Various single and multi split systems, up to eight indoor models connectable to one outdoor unit, afford highest comfort. page 6 MSC/MS Cooling Only Wall mounted systems MSC/MSH Cooling/Heating Wall mounted systems 10 Systems with electrical heater 41 PLA 4-way Ceiling cassette systems 42 PCA Ceiling suspended systems 43 PCA Ceiling suspended systems stainless steel 44 PKA Wall mounted systems 45 MCF Cooling Only Floor or ceiling mounted systems 12 MCFH Cooling/Heating Floor or ceiling mounted systems 13 PSA Floor mounted systems 46 MSZ Inverter Wall mounted systems 14 PEAD Ceiling concealed systems 47 MSZ Deluxe Inverter Wall mounted systems 16 PEAD Compact ceiling concealed systems 48 MFZ Inverter Floor mounted systems 17 PEH Ceiling concealed systems R407C 49 SLZ Inverter 4-way Ceiling cassette systems 18 Connection kit for external heat exchanger 50 SEZ Inverter Ceiling concealed systems 19 Outdoor units Overview 51 PU/PUH Non-Inverter 52 SUZ/PUHZ-P Standard Inverter 53 PUHZ-RP Power Inverter 54 Accessories Mr. Slim Series 56 Combinations with M Series 60 MSX Multi Split Cooling Systems 2 to 4 indoor units 20 MXZ Inverter Multi Split 2 to 4 indoor units 2 to 8 indoor units 23 28 Optional Interfaces for M Series Inverter 35 Acessories M Series Combinations with Mr. Slim Series 4 8 The Mr. Slim Series is especially suited for commercial applications as shops or small offices. Single and multi split systems with simultaneous operation are available. page 39 36 38 Content City Multi Series This outstanding range is the perfect solution for big and extensive projects. Up to 42 indoor units in one refrigeration cycle are realisable. A wide range of indoor and outdoor models ensure high flexibility for planning. page 61 Outdoor units Overview 68 PUMY Outdoor units 69 Y-Series PUY/PUHY Outdoor units 70 WY-Series PQHY Outdoor units 74 R2-Series PURY Outdoor units 75 WR2-Series PQRY Outdoor units 77 Indoor units Overview 78 PMFY 1-way Ceiling cassette systems 79 PLFY 2-way Ceiling cassette systems 80 PLFY 4-way Ceiling cassette systems 81 PKFY Wall mounted systems 83 PCFY Ceiling suspended systems 84 PFFY Floor mounted systems 85 PEFY Ceiling concealed systems 87 Connection kit for external heat exchanger 91 Close Control Systems PFD Series 92 Control Systems 94 Accessories City Multi 99 Lossnay Ventilation systems with total heat recovery Wall mounted, ceiling suspended and ceiling concealed units 100 Roof Top Systems 103 Dehumidifier 105 5 Single and Multi Split Systems Pleasant and healthy climate Series 6 Our M Series products provide whisper-quiet, energy-efficient cooling and heating for small to medium-sized rooms. The indoor units are very compact and blend unobtrusively with your interior décor. Their innovative Catechin and antiallergenic filters have a special coating that prevents the spread of dust, odours, bacteria and viruses. In the deluxe models special Plasma Duo filters provide even more efficient air filtration. The wall mounted systems, floor standing systems, ceiling suspended systems, concealed ducted systems and ceiling cassette systems are all easy to install. And they are very easy to use, because of their infrared remote controls with advanced fuzzy logic. The outdoor units come pre-charged with R410A refrigerant. Highlights: ● R410A refrigerant ● Large selection of indoor units ● Very flexible installation options: choose from wall mounted, floor standing, ceiling suspended and ducted units and ceiling cassettes ● Systems with cooling capacities from 2.3 – 14.0 kW ● Multi split inverter systems for up to eight indoor units ● Whisper-quiet ‘sleep mode’ with just 21dB(A) (MSZ-GA 22/25 VA) and a gentle airflow for a pleasant atmosphere ● Compact dimensions for easy and unobtrusive installation ● Note that the inverter and non-inverter series are not compatible because of the way the systems communicate. The non-inverter units communicate via the conventional RAC control system, whilst the inverter units are fitted with the new A-Control system ● All wall mounted units feature slim and modern flat panel design ● The intelligent Econo Cool function allows the temperature to be two degrees higher than set without any reduction in cooling comfort. The air outlet is swivelled automatically to distribute cool air throughout the room ● Automatic re-start after power failures ● Power-saving, low noise and low vibration rotary piston compressor ● Special function for saving your ‘personal climate settings’ ● Optional fine dust filters (antiallergenic enzyme filters) for air purification ● Special ‘Swing Mode’ for fast and power-saving room cooling ● Winter kits for cooling operation down to -10°C for all outdoor inverter units ● All indoor units are certified by a German Hygiene Institute (tested for conformity with VDI 6022 Sheets 1 and 3) Range of M-Series: ● Cooling:Indoor 21° to 32° C (DB) / 15° to 23° C (WB) Outdoor -10° to 43° C (DB) Inverter models Outdoor 21° to 43° C (DB) Non-Inverter models ● Heating:Indoor 20° to 27° C (DB) Outdoor -9° to 21° C DB) / -10° to 15° C (WB) 7 Series Single Split - Cooling Only Wall Mounted Systems • Three fan levels and ‘Swing Highlights • Compact indoor units for easy installation • Quiet night mode with a noise level of just 25 dB(A) (MSC-GA20/25VB) • Power-saving rotary piston compressor • Automatic restart in case of power failures • The outdoor units come precharged with R410A refrigerant • Infrared remote control with fuzzy logic and programmable 24-hour timer Mode’ function for quicker room cooling • Automatic adjustment of the airflow in cooling mode • Five selectable air outlet angles for individual direction of the airflow • Long-life, washable Catechin filter included as standard equipment Accessories • Fine dust filters, see page 36 MSC-WALL MOUNTED SYSTEMS, COOLING ONLY Indoor Unit Cooling Capacity Energy Effiziency Range Airflow (m³/h) Noise dB(A) Weight Dimensions (mm) Eletrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (kW) Low High Low High (kg) Width Depth Height (A) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MSC-GA20VB 2.3 A 276 474 25 36 9 815 244 278 220-240, 1, 50 MSC-GA25VB 2.5 A 306 474 25 36 9 815 244 278 220-240, 1, 50 MSC-GA35VB 3.5 B 324 582 26 40 10 815 244 278 220-240, 1, 50 0.17 0.17 0.19 MU-GA20VB 0.715 MU-GA25VB 0.775 MU-GA35VB 1.12 1800 45 31 800 285 550 20 10 0.60 6 10 220-240, 1, 50 1800 45 31 800 285 550 20 10 0.60 6 10 220-240, 1, 50 1902 49 30 800 285 550 25 10 0.70 6 10 220-240, 1, 50 3.17 10 3.40 10 5.02 10 * Factory charged to 7 m pipe length, optional charging on page 36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 8 Series Single Split - Cooling Only Wall Mounted Systems Highlights • Compact indoor units for easy installation • Automatic restart in case of power failures • Power-saving rotary piston compressor • The outdoor units come precharged with R410A refrigerant • Infrared remote control with fuzzy logic and programmable 24-hour timer • Three fan levels and ‘Swing Mode’ function for quicker room cooling • Long-life, washable Catechin filter • Automatic adjustment of the airflow in cooling mode • Five selectable air outlet angles for individual direction of the airflow Accessories • Fine dust filters, see page 36 MS-WALL MOUNTED SYSTEMS, COOLING ONLY Indoor Unit Cooling Capacity Energy Effiziency Range Airflow (m³/h) Noise dB(A) Weight Dimensions (mm) Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply(V, Phase, Hz) Running Current Recommend Safety Fuse (kW) Low High Low High (kg) Width Depth Height (A) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MS-GA50VB 5.0 D 528 768 34 42 16 1100 258 325 220-240, 1, 50 MS-GA60VB 6.5 D 588 768 37 45 16 1100 258 325 220-240, 1, 50 MS-GA80VB 8.5 D 684 954 37 47 16 1100 258 325 220-240, 1, 50 0.30 0.30 0.34 MU-GA50VB 1.81 MU-GA60VB 2.48 MU-GA80VB 3.26 2196 52 44 850 290 605 25 10 1.45 6 12 220-240, 1, 50 2322 53 60 850 290 605 25 10 2.0 6 16 220-240, 1, 50 2940 55 75 840 330 850 30 15 2.4 10 16 220-240, 1, 50 7.93 16 10.82 25 14.42 25 * Factory charged to 7 m pipe length, optional charging on page 36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 9 Series Single Split - Cooling/Heating Wall Mounted Systems Highlights • Comfortable indoor climate all year round • Compact indoor units for easy installation • Quiet night mode with a noise level of just 25 dB(A) (MSC-GA20/25VB) • Automatic restart in case of power failures • Power-saving rotary piston compressor • The outdoor units come precharged with R410A refrigerant • Infrared remote control with fuzzy logic and programmable 24-hour timer • Three fan levels and ‘Swing Mode’ function for quicker room cooling • Automatic adjustment of the airflow in cooling mode • Five selectable air outlet angles for individual direction of the airflow • Long-life, washable Catechin filter Accessories • Fine dust filters, see page 36 MSC-WALL MOUNTED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (kW) (A) (A) MSC-GA20VB 2.3 2.5 A/A 276 474 25 36 9 815 244 278 220-240, 1, 50 MSC-GA25VB 2.65 3.0 A/A 306 474 25 36 9 815 244 278 220-240, 1, 50 MSC-GA35VB 3.5 3.7 A/A 324 582 26 40 10 815 244 278 220-240, 1, 50 0.17 0.17 0.19 MUH-GA20VB 0.715 0.69 1800 47 32 800 285 550 20 10 0.62 6 10 220-240, 1, 50 MUH-GA25VB 0.82 0.82 1902 49 32 800 285 550 20 10 1.00 6 10 220-240, 1, 50 MUH-GA35VB 1.09 1.02 1902 49 35 800 285 550 25 10 1.00 6 10 220-240, 1, 50 3.00 10 3.43 10 4.65 10 * Factory charged to 7 m pipe length, optional charging on page 36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 10 Series Single Split - Cooling/Heating Wall Mounted Systems Highlights • Comfortable indoor climate all year round • Compact indoor units for easy installation • Automatic restart in case of power failures • Power-saving rotary piston compressor • The outdoor units come precharged with R410A refrigerant • Infrared remote control with fuzzy logic and programmable 24-hour timer • Three fan levels and ‘Swing Mode’ function for quicker room cooling • Automatic adjustment of the airflow in cooling mode • Five selectable air outlet angles for individual direction of the airflow • Long-life, washable Catechin filter Accessories • Fine dust filters, see page 36 MSH-WALL MOUNTED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MSH-GA50VB 5.0 5.2 C/C 528 768 34 42 16 1100 258 325 220-240, 1, 50 MSH-GA60VB 6.3 7.2 D/D 588 768 37 45 16 1100 258 325 220-240, 1, 50 MSH-GA80VB 8.5 9.4 D/E 684 954 37 47 16 1100 258 325 220-240, 1, 50 0.30 0.30 0.34 MUH-GA50VB 1.78 1.61 2196 52 47 850 290 605 25 10 1.75 6 12 220-240, 1, 50 MUH-GA60VB 2.41 2.48 2760 53 74 840 330 850 25 10 2.15 6 16 220-240, 1, 50 MUH-GA80VB 3.26 3.43 2940 55 77 840 330 850 30 15 2.30 10 16 220-240, 1, 50 7.93 16 10.39 25 14.42 25 * Factory charged to 7 m pipe length, optional charging on page 36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 11 Series Single Split - Cooling Only Floor Standing or Ceiling Suspended Systems • All connections easily acces- Highlights • The versatile 2-in-1 model is supplied with multi-purpose brackets for quick and easy floor or ceiling installation • Infrared remote control with fuzzy logic and programmable 24-hour timer • Automatic restart in case of power failures • Power-saving rotary piston compressor • The outdoor units come precharged with R410A refrigerant • Lightweight compact design for easier installation sible • Automatic adjustment of the air outlet angle and airflow. Five selectable air outlet angles for individual direction of the airflow • Three fan levels and ‘Swing Mode’ function for quicker room cooling Accessories • Fine dust and odour filters, see page 36 MCF-FLOOR STANDING OR CEILING SUSPENDED SYSTEMS, COOLING ONLY Indoor Unit Cooling Capacity Energy Effiziency Range Airflow (m³/h) Noise dB(A) Weight Dimensions (mm) Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (kW) Low High Low High (kg) Width Depth Height (A) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MCF-GA35VB 3.5 B 474 678 34 44 25 1100 180 650 220-240, 1, 50 MCF-GA50VB 4.8 D 492 780 36 46 25 1100 180 650 220-240, 1, 50 MCF-GA60VB 6.0 E 642 840 42 48 25 1100 180 650 220-240, 1, 50 0.26 0.30 0.36 MUCF-GA35VB 1.16 MUCF-GA50VB 1.81 MUCF-GA60VB 2.45 1914 49 36 780 255 540 25 10 0.75 6 12 220-240, 1, 50 2196 52 44 850 290 605 25 10 1.45 6 12 220-240, 1, 50 2322 53 60 850 290 605 25 10 1.85 6 16 220-240, 1, 50 4.89 10 7.98 16 10.62 25 * Factory charged to 7 m pipe length, optional charging on page 36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 12 Series Single Split - Cooling/Heating Floor Standing or Ceiling Suspended Systems Highlights • Comfortable indoor climate all year round • The versatile 2-in-1 model is supplied with multi-purpose brackets for quick and easy floor or ceiling installation • Infrared remote control with fuzzy logic and programmable 24-hour timer • Automatic restart in case of power failures • Power-saving rotary piston • The outdoor units come pre- charged with R410A refrigerant • Compact design for easy installation and quick access to the connections • Three fan levels and automatic adjustment of the air outlet angle Accessories • Fine dust and odour filters, see page 36 compressor MCFH-FLOOR STANDING OR CEILING SUSPENDED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low Medium High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Heigh (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MCFH-GA35VB 3.5 3.7 B/A 492 636 780 36 46 25 1100 180 650 220-240, 1, 50 MCFH-GA50VB 4.8 5.0 D/E 570 696 840 39 48 25 1100 180 650 220-240, 1, 50 MCFH-GA60VB 6.0 6.8 E/F 642 744 840 42 48 25 1100 180 650 220-240, 1, 50 0.30 0.36 0.36 MUCFH-GA35VB 1.16 1.02 1710 49 40 780 255 540 25 10 1.00 6 12 220-240, 1, 50 MUCFH-GA50VB 1.81 1.89 2196 52 47 850 290 605 25 10 1.85 6 12 220-240, 1, 50 MUCFH-GA60VB 2.45 2.72 2760 53 74 840 330 850 25 10 2.2 6 16 220-240, 1, 50 4.85 10 8.01 16 10.51 25 * Factory charged to 7 m pipe length, optional charging on page 36 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 13 Series Inverter Single Split - Cooling/Heating Wall Mounted Systems • Three fan levels and ‘Swing Highlights • DC inverter technology and envi- Mode’ function for fast room cooling. The Super-High fan setting in automatic mode cools or heats the room very quickly • Five selectable air outlet angles for individual direction of the airflow • Special ‘Quick Clean Body’ design for easy cleaning • Long-life, washable Catechin filter ronment-friendly R410A refrigerant ensure very economical operation and comfortable room climate all year round • Compact wall mounted units for easy installation • Quiet night mode with a noise level of just 21 dB(A) (MSZGA22/25) • Infrared remote control with fuzzy logic and 24-hour timer • Winter kit for cooling operation down to -10°C Accessories • Anti-allergenic enzyme filter • Quick Clean Kit, see page 36 MSZ-WALL MOUNTED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MSZ-GA22VA 2.2 (1.4 - 3.0) 3.3 (1.2 - 4.2) A/A 234 480 21 36 9 780 210 298 220-240, 1, 50 MSZ-GA25VA 2.5 (0.9 - 3.0) 3.2 (0.9 - 4.5) A/A 234 480 21 36 9 780 210 298 220-240, 1, 50 MSZ-GA35VA 3.5 (1.0 - 3.9) 4.0 (0.9 - 5.0) A/A 246 480 22 36 9 780 210 298 220-240, 1, 50 0.25 0.25 0.25 Multisplit MXZ -- MUZ-GA25VA 0.64 0.76 1890 46 31 800 285 550 20 12 0.85 6 10 220-240, 1, 50 MUZ-GA35VA 1.08 1.06 2178 47 33 800 285 550 20 12 0.90 6 10 220-240, 1, 50 - 3.2 10 5.0 10 * Factory charged to 7 m pipe length, optional charging on page 37 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 14 Series Inverter Single Split - Cooling/Heating Wall Mounted Systems Highlights • DC inverter technology and environment-friendly R410A refrigerant ensure very economical operation and comfortable room climate all year round • Compact wall mounted units for easy installation • Infrared remote control with fuzzy logic and 24-hour timer • Winter kit for cooling operation down to -10°C • Automatic airflow adjustment in heating and cooling mode • Three fan levels and ‘Swing Mode’ function for fast room cooling. The Super-High fan setting in automatic mode cools or heats the room very quickly • Five selectable air outlet angles for individual direction of the airflow • Long-life, washable Catechin filter • Special ‘Quick Clean Body’ design for easy cleaning Accessories • Anti-allergenic enzyme filter • Quick Clean Kit, see page 36 MSZ-WALL MOUNTED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensios (kW) (kW) Cooling/Heating (m³/h) Low High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MSZ-GA50VA 5.0 (0.9 - 5.9) 5.9 (0.9 - 7.8) A/A 498 852 31 48 16 1100 258 325 220-240, 1, 50 MSZ-GA60VA 6.0 (0.9 - 6.7) 6.8 (0.9 - 8.1) B/B 522 1032 32 54 16 1100 258 325 220-240, 1, 50 MSZ-GA71VA 7.1 (0.9 - 8.3) 8.1 (0.9 - 9.6) C/C 564 1032 33 54 16 1100 258 325 220-240, 1, 50 0.45 0.60 0.60 MUZ-GA50VA 1.46 1.63 2940 53 53 840 330 850 30 15 1.80 6 12 220-240, 1, 50 MUZ-GA60VA 1.93 1.94 2940 53 53 840 330 850 30 15 2.20 6 16 220-240, 1, 50 MUZ-GA71VA 2.42 2.45 2940 53 58 840 330 850 30 15 2.35 10 16 220-240, 1, 50 6.23 16 8.23 25 10.4 25 * Factory charged to 7 m pipe length, optional charging on page 37 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 15 Series Inverter Single Split - Cooling/Heating Deluxe Wall Mounted Systems Highlights • The innovative i-see sensor monitors room temperature with infrared beams and automatically directs the airflow towards the coolest or warmest part of the room • Plasma Duo filter technology removes dust, odours, bacteria and allergens from the air • DC inverter technology and environment-friendly R410A refrigerant ensure very economical operation • Infrared remote control with fuzzy logic and 24-hour timer • Winter kit for cooling operation down to -10°C • Automatic airflow adjustment in heating and cooling mode • Three fan levels and ‘Swing Mode’ function for fast room cooling. The Super-High fan setting in automatic mode cools or heats the room very quickly • Five selectable air outlet angles for individual direction of the airflow • Whisper-quiet night mode, just 21 dB(A) up to 22 dB(A) • Special ‘Quick Clean Body’ design for easy cleaning Accessories • Odour filter • Quick Clean Kit, see page 36 MSZ-DELUXE WALL MOUNTED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MSZ-FA25VA 2.5 (0.9 - 3.2) 3.2 (0.9 - 5.0) A/A 252 594 21 36 10 780 198 298 220-240, 1, 50 MSZ-FA35VA 3.5 (1.0 - 4.1) 4.0 (0.9 - 6.0) A/A 258 594 22 36 10 780 198 298 220-240, 1, 50 0.25 0.25 MUZ-FA25VA 0.59 0.73 2058 46 33 800 285 550 20 12 0.9 6 10 220-240, 1, 50 MUZ-FA35VA 0.93 0.99 2004 47 37 800 285 550 20 12 1.05 6 10 220-240, 1, 50 3.5 10 4.6 10 * Factory charged to 7 m pipe length, optional charging on page 37 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 16 Series Inverter Single Split - Cooling/Heating Floor Standing Systems Highlights • Comfortable climate all year round • Whisper-quiet operation from just 22 dB(A) (MFZ-KA25VA) • Infrared remote control with fuzzy logic and 24-hour timer • The outdoor units come precharged with R410A refrigerant • Winter kit for cooling operation down to -10°C • The DC inverter technology saves power and maximises comfort by reducing temperature fluctuations in the air output significantly • The variable air outlet with two fans (up and down) ensure a comfortable room climate, particularly in the winter season • Very light and compact design for versatile installation • Long-life washable Catechin filter and anti-allergenic enzyme filter included as standard equipment • Automatic restart in case of power failures • Three standard fan levels and an additional Super High fan level in automatic mode for accelerated cooling and heating MFZ-FLOOR STANDING SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low High Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) MFZ-KA25VA 2.5 (0.9 - 3.4) 3.4 (0.9 - 5.1) A/A 288 522 22 32 14 700 200 600 220-240, 1, 50 MFZ-KA35VA 3.5 (0.9 - 3.9) 4.0 (0.9 - 6.2) A/A 300 546 23 38 14 700 200 600 220-240, 1, 50 MFZ-KA50VA 4.8 (0.9 - 5.4) 6.0 (0.9 - 7.9) B/C 426 642 32 39 14 700 200 600 220-240, 1, 50 0.27 0.35 0.38 SUZ-KA25VA 0.58 0.83 1900 46 33 800 285 550 20 12 0.9 6 10 220-240, 1, 50 SUZ-KA35VA 1.09 1.10 1900 47/48 37 800 285 550 20 12 1.05 6 10 220-240, 1, 50 SUZ-KA50VA 1.55 1.86 2940 53/55 53 840 330 850 30 15 1.6 6 12 220-240, 1, 50 3.4 10 4.9 16 7.4 25 * Factory charged to 7 m pipe length, optional charging on page 37 The values given in the table for the noise level reflect the levels measured at a position 1.0 m in front of and 0.8 m below the unit in anechoic chamber 17 Series Inverter Single Split - Cooling/Heating 4-Way In-Ceiling Cassette for European Ceiling Grid • Winter kit for cooling operation Highlights • Standard European ceiling grid down to -10°C • Ready for outdoor air duct connection • Automatic restart in case of power failures • Outdoor units come pre-charged with R410A refrigerant • With drain pump for 500 mm height difference dimensions for easy installation in existing suspended ceilings, installation recess depth just 235 mm • Noise-optimised construction: just 28 dB(A) (SLZ-KA25VAL) • Lightweight, installation-friendly design: just 16.5 kg • Three-stage fan for optimal airflow control • Infrared remote control with 12-hour On/Off timer as standard equipment • Long-life filters included as standard equipment, cleaning required just every 2,500 hours in normal operation Accessories • PAR-21MAAT-E wired remote control with week timer, see page 56 SLZ 4-WAY IN-CEILING CASSETTE, COOLING & HEATING Indoor Unit Grille Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise dB(A) Weight (incl. Grille) Dimensions Dimensions (Grille) (kW) (kW) Cooling/Heating (m³/h) Low Medium High Low High (kg) (mm) Width Depth Height* (mm) Width Depth Height** Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A*** Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (A) (A) SLZ-KA25VAL SLP-2AL 2.5 (0.9 - 3.2) 3.0 (0.9 - 4.5) A/A 480 540 600 28 37 16.5 (19.5) 570 570 235 650 650 20 220-240, 1, 50 SLZ-KA35VAL SLP-2AL 3.5 (1.0 - 3.9) 4.0 (0.9 - 5.0) A/A 480 540 660 29 38 16.5 (19.5) 570 570 235 650 650 20 220-240, 1, 50 SLZ-KA50VAL SLP-2AL 4.6 (1.1 - 5.2) 5.0 (0.9 - 6.5) C/C 480 540 660 30 39 16.5 (19.5) 570 570 235 650 650 20 220-240, 1, 50 0.4 0.6 0.62 SUZ-KA25VA 0.69 0.83 2058 46 33 800 285 550 20 12 0.9 6 10 220-240, 1, 50 SUZ-KA35VA 1.06 1.10 2004 47/48 37 800 285 550 20 12 1.05 6 10 220-240, 1, 50 SUZ-KA50VA 1.63 1.55 2940 53/55 53 840 330 850 30 15 1.6 6 12 220-240, 1, 50 3.5 10 4.9 16 8.0 20 * Necessary height ** Visible grille height *** Factory charged to 7 m pipe length, optional charging on page 37 The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber while cooling. 18 Series Inverter Single Split - Cooling/Heating Concealed Ducted Systems Highlights • Concealed ducted units with compact dimensions, just 225 mm up to 270 mm high • Self-diagnostics system for easy service • Both indoor and outdoor units are extra quiet • Air intake from below or from the rear • Power-saving system • Outdoor units come pre-charged with R410A refrigerant • Winter kit for cooling operation down to -10°C • Equipped with high-quality wired remote control featuring multi-language display, week timer and self-diagnostics function • The DC inverter technology saves power and maximises comfort by significantly reducing temperature fluctuations in the air output Accessories • PAC-1000FT air purification filter for SEZ-KA 35/50/60 and long-life PAC-KE32LAF-F air filter, see page 36 SEZ CONCEALED DUCTED SYSTEMS, COOLING & HEATING Indoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Static Pressing Noise dB(A) Weight Dimensions (kW) (kW) Cooling/Heating (m³/h) Low High (Pa) Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Outdoor Unit Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Charge R410A* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (A) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas (kW) (A) (A) SEZ-KC25VA 2.5 (0.9 - 3.2) 3.0 (0.9 - 4.5) A/A 288 474 5 25 36 19.0 790 550 225 220-240, 1, 50 SEZ-KA35VA 3.5 (1.0 - 3.9) 4.0 (0.9 - 5.0) A/A 600 780 30 (50) 30 35 33.5 1100 700 270 220-240, 1, 50 SEZ-KA50VA 5.0 (1.1 - 5.6) 5.9 (1.1 - 7.2) C/C 720 1020 30 (50) 31 39 33.5 1100 700 270 220-240, 1, 50 SEZ-KA60VA 5.5 (1.1 - 6.3) 6.9 (0.9 - 8.0) C/D 720 1200 30 (50) 32 43 33.5 1100 700 270 220-240, 1, 50 SEZ-KA71VA 7.1 (0.9 - 8.3) 8.1 (0.9 - 10.4) C/B 720 1200 30 (50) 32 43 35.0 1100 700 270 220-240, 1, 50 0.40 0.59 0.68 0.95 0.6 SUZ-KA25VA 0.73 0.83 2058 46 33 800 285 550 20 12 0.9 6 10 220-240, 1, 50 SUZ-KA35VA 1.06 1.10 2004 47/48 37 800 285 550 20 12 1.05 6 10 220-240, 1, 50 SUZ-KA50VA 1.78 1.84 2940 53/55 53 840 330 850 30 15 1.6 6 12 220-240, 1, 50 SUZ-KA60VA 1.96 2.45 2940 53/55 53 840 330 850 30 15 1.8 6 16 220-240, 1, 50 SUZ-KA71VA 2.4 2.36 2940 53/55 58 840 330 850 30 15 2.0 10 16 220-240, 1, 50 3.5 10 4.9 10 8.0 20 9.0 20 10 25 * Factory charged to 7 m pipe length, optional charging on page 37 The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber 19 Series Multi Split Cooling Systems for 2, 3 or 4 Wall Mounted Units MSX system highlights: • Cooling performance from 2.8 – 7.3 kW (depends on outdoor unit), connects up to 4 wall mounted systems with individually-variable output levels • Connects only as many wall units as needed, additional units can be added for more cooling capacity at any time • Solutions for individual cooling of 2, 3 or 4 rooms possible • Automatic restart in case of power failures • Quiet outdoor units with the latest power-saving rotary piston compressors, optimised for operation with R410A • Improved energy efficiency with R410A refrigerant • Wall mounted units with infrared remote control and programmable 24-hour timer • Whisper-quiet wall mounted units for maximum comfort, just 25 dB(A) (MSC-GA20VB) • See page 8 for detailed descriptions of the indoor units MUX OUTDOOR UNITS, COOLING ONLY Outdoor Unit Cooling Capacity Airflow Noise Weight Dimensions Max. Pipe Size Max. Height Difference Number of compressors Charge R410A* Pipe Size (mm) (kW) (m³/h) dB(A) (kg) Width Depth Height (m) (m) (kg) Ø (mm) Liquid Gas Electrical Supply (V, Phase, Hz) (kW) Max. Power Consumption (A) Running Current (A) Recommend Safety Fuse Connectable Indoor Units (Number/Type) MUX-2A28VB 2.8 1914 49 35 780 255 540 30 10 1 0.90 (2 x 20) 2x6 2 x 10 220-240, 1, 50 MUX-2A59VB 5.9 2460 52 66 840 330 640 30 10 2 1.0 (35) 2x6 2 x 10 220-240, 1, 50 MUX-2A70VB 7.0 2460 52 68 840 330 640 30 10 2 0.95 (35) 2x6 2 x 10 220-240, 1, 50 MUX-3A60VB 6.0 2460 52 65 840 330 640 45 10 2 0.80 (25) 3x6 3 x 10 220-240, 1, 50 MUX-3A63VB 6.3 2460 52 67 840 330 640 45 10 2 0.85 (35) 3x6 3 x 10 220-240, 1, 50 MUX-4A73VB 7.3 2760 52 76 840 330 850 60 10 2 1.05 (2 x 25) 4x6 4 x 10 220-240, 1, 50 0.8 3.25 10 1 - 2 / 2 x 20 2.08 8.96 20 1 - 2 / 1 x 20 + 1 x 35 2.64 11.49 20 1 - 2 / 2 x 35 1.99 8.18 20 1 - 3 / 3 x 25 2.09 8.84 20 1 - 3 / 2 x 20 + 1 x 35 2.36 9.75 20 1 - 4 / 2 x 25 + 2 x 35 * Charging for the max. pipe length see page 37. The values given in the brackets refer to the connected indoor units MSC-GA20/35VB. 20 Series MSX Multi Split Cooling Systems for 2 Wall Mounted Units System combinations: MSX-2A28VB Total cooling output 2.8 kW, up to two wall mounted units. The system: • 1 x MUX-2A28VB outdoor unit • 2 x MSC-GA20VB indoor units (A), (B) MSC-GA20VB (A) Distribution of the total cooling capacity MUX-2A28VB MSC-GA20VB (B) MUX-2A28VB 2,8 kW Cooling capacity of indoor units Energy efficiency A B range 1 indoor unit in operation 2.40 – – 2.40 B B 2 indoor units in operation 1.40 1.40 A MSX-2A59VB Total cooling output 5.9 kW, up to two wall mounted units. The system: • 1 x MUX-2A59VB outdoor unit • 1 x MSC-GA35VB indoor unit (A) • 1 x MSC-GA20VB indoor unit (B) MSC-GA35VB (A) Distribution of the total cooling capacity MUX-2A59VB MSC-GA20VB (B) MUX-2A59VB 5,9 kW Cooling capacity of indoor units Energy efficiency A B range 1 indoor unit in operation 3.50 – – 2.40 D C 2 indoor units in operation 3.50 2.40 C MSX-2A70VB Total cooling output 7.0 kW, up to two wall mounted units. The system: • 1 x MUX-2A70VB outdoor unit • 2 x MSC-GA35VB indoor units (A), (B) MSC-GA35VB (A) Distribution of the total cooling capacity MUX-2A70VB MSC-GA35VB (B) MUX-2A70VB 7,0 kW Cooling capacity of indoor units Energy efficiency A B range 1 indoor unit in operation 3.50 – – 3.50 D D 2 indoor units in operation 3.50 3.50 D 21 MSX-3A60VB Total cooling output 6.0 kW, up to three wall mounted units. The system: • 1 x MUX-3A60VB outdoor unit • 3 x MSC-GA25VB indoor units (A), (B), (C) MSC-GA25VB (A) MUX-3A60VB MSC-GA25VB (B) MSC-GA25VB (C) Distribution of the total cooling capacity MUX-3A60VB 6,0 kW Cooling capacity of indoor units Energy efficiency A B C range 1 indoor unit in operation 2.60 – – – 2.90 – – – 2.90 B D D 2 indoor units in operation 2.60 2.60 – 2.80 – 1.75 – 2.80 2.00 C C B 2.50 1.75 1.75 B 3 indoor units in operation MSX-3A63VB Total cooling output 6.3 kW, up to three wall mounted units. The system: • 1 x MUX-3A63VB outdoor unit • 1 x MSC-GA35VB indoor units (A) • 2 x MSC-GA20VB indoor units (B), (C) MSC-GA35VB (A) MUX-3A63VB MSC-GA20VB (B) MSC-GA20VB (C) Distribution of the total cooling capacity MUX-3A63VB 6,3 kW Cooling capacity of indoor units Energy efficiency A B C range 1 indoor unit in operation 3.50 – – – 2.40 – – – 2.40 D C C 2 indoor units in operation 3.50 3.50 – 2.40 – 1.45 – 2.40 1.45 C C A 3.40 1.45 1.45 B 3 indoor units in operation MSX-4A73VB Total cooling output 7.3 kW, MSC-GA35VB (A) up to four wall mounted units. The system: • 1 x MUX-4A73VB outdoor unit • 2 x MSC-GA35VB indoor units (A), (B) • 2 x MSC-GA25VB indoor units (C), (D) Distribution of the total cooling capacity MSC-GA35VB (B) MUX-4A73VB MUX-4A73VB 7,3 kW 1 indoor unit in operation MSC-GA25VB (C) MSC-GA25VB (D) 2 indoor units in operation 3 indoor units in operation 4 indoor units in operation 22 Cooling capacity of indoor units Energy efficiency A B C D range 3.40 – – – D – 3.40 – – D – – 2.75 – D – – – 2.75 D 1.95 1.95 – – B 3.40 – 2.70 – C 3.40 – – 2.70 C – 3.40 2.70 – C – 3.40 – 2.70 C – – 1.70 1.70 B 1.95 1.95 2.80 – B 1.95 1.95 – 2.80 B 3.40 – 1.70 1.70 B – 3.40 1.70 1.70 B 1.95 1.95 1.70 1.70 B Series Inverter Multi Split Systems for 2, 3 or 4 Indoor Units MXZ system highlights • Comfortable room temperature all year round • Inverter-controlled, power- saving scroll compressors for whisper-quiet operation and minimum vibrations • Inverter technology saves power and ensures perfect climate comfort • Outdoor unit pre-charged with R410A refrigerant for up to 40 m piping length • Unobtrusive outdoor installation – only one outdoor unit required for up to four indoor units • Wide selection of indoor units in wall mounted, floor standing, ceiling suspended, ducted and ceiling cassette versions. Both M series indoor units and Mr. Slim series indoor units with the new A-Control system can be connected, see page 38 • Indoor units with different capacities can be combined to suit individual room requirements • Special function for saving your individual climate settings • Automatic restart in case of power failures • Winter kit for cooling operation down to -10°C MXZ INVERTER OUTDOOR UNITS, COOLING & HEATING Outdoor Unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Pipe Size Electrical Supply (V, Phase, Hz) Max. Capacity (kW) (kW) Cooling/Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) Ø (mm) Liquid Gas (kW) Running Current Recommend Safety Fuse Connectable Indoor Units (Number) Cooling Heating (A) (A) MXZ-2A40VA 4.0 (1.1 - 4.5) 4.5 (1.0 - 5.0) A/A 1860 44 40 800 285 550 30 15/10** 2x6 2 x 10 220-240, 1, 50 MXZ-2A52VA 5.2 (1.1 - 6.0) 6.4 (1.0 - 7.2) A/A 1860 45 40 800 285 550 30 15/10** 2x6 2 x 10 220-240, 1, 50 MXZ-3A54VA 5.4 (2.9 - 6.8) 6.8 (2.6 - 9.0) A/A 2525 44 57 840 330 710 50 15/10** 3x6 3 x 10 220-240, 1, 50 MXZ-4A71VA 7.1 (3.7 - 8.8) 8.6 (3.4 - 9.0) A/A 2525 45 56 840 330 710 60 15/10** 4x6 1 x 12 / 3 x 10 220-240, 1, 50 MXZ-4A80VA 8.0 (3.7 - 9.2) 9.4 (3.4 - 11.6) A/A 2530 44 70 900 360 900 70 10 4x6 1 x 12 / 3 x 10 220-240, 1, 50 1.045 0.945 4.78 16 2 1.505 1.705 6.55 16 2 1.29 1.45 5.69 25 2-3 1.93 1.95 8.48 25 2-4 2.2 1.93 9.62 25 2-4 * Charges for max. pipe lengths see page 37. ** 15 m for installation below, 10 m for installation of the outdoor unit above the indoor units Note: The Multi Split Systems operate in either cooling or heating mode. At least two indoor units must be connected. 23 MXZ-2A40VA Combination Model Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating 22 25 35 22+22 22+25 22+35 25+25 25+35 MXZ-2A52VA Combination Model Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating 22 25 35 22+22 22+25 22+35 25+25 25+35 35+35 MXZ-3A54VA Combination Model Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating 22 25 35 50 22+22 22+25 22+35 22+50 25+25 25+35 25+50 35+35 35+50 50+50 22+22+22 22+22+25 22+22+35 22+22+50 22+25+25 22+25+35 22+25+50 22+35+35 25+25+25 25+25+35 25+25+50 25+35+35 24 • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: MSZ-FA25/35, MSZ-GA22/25/35 MFZ-KA25/35 SEZ-KC25, SEZ-KA35 SLZ-KA25/35 Capacity (kW) B A 2.2 / 3.3 2.5 / 3.6 3.5 / 4.0 1.9 / 2.2 1.8 / 2.06 1.51 / 1.7 1.95 / 2.2 1.67 / 1.85 Total 2.2 (0.9-3.0) / 3.3 (0.9-4.0) 2.5 (0.9-3.3) / 3.6 (0.9-4.5) 3.5 (0.9-4.0) / 4.0 (0.9-4.8) 3.8 (1.1-4.3) / 4.4 (1.0-4.8) 3.9 (1.1-4.3) / 4.4 (1.0-4.8) 3.9 (1.1-4.4) / 4.4 (1.0-4.9) 3.9 (1.1-4.4) / 4.4 (1.0-4.9) 4.0 (1.1-4.5) / 4.5 (1.1-5.0) 1.9 / 2.2 2.07 / 2.34 2.39 / 2.7 1.95 / 2.2 2.33 / 2.65 • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: MSZ-FA25/35, MSZ-GA22/25/35 MFZ-KA25/35 SEZ-KC25, SEZ-KA35 SLZ-KA25/35 Capacity (kW) B A 2.2 / 3.3 2.5 / 3.6 3.5 / 4.0 2.2 / 3.05 2.2 / 2.9 1.93 / 2.43 2.5 / 3.15 2.13 / 2.63 2.6 / 3.2 Total 2.2 (0.9-3.0) / 3.3 (0.9-4.0) 2.5 (0.9-3.3) / 3.6 (0.9-4.5) 3.5 (0.9-4.0) / 4.0 (0.9-4.8) 4.4 (1.1-5.3) / 6.1 (1.0-6.7) 4.7 (1.1-5.4) / 6.2 (1.0-6.8) 5.0 (1.1-5.6) / 6.3 (1.0-7.0) 5.0 (1.1-5.6) / 6.3 (1.0-7.0) 5.1 (1.1-5.8) / 6.3 (1.0-7.1) 5.2 (1.1-6.0) / 6.4 (1.0-7.2) 2.2 / 3.05 2.5 / 3.3 3.07 / 3.87 2.5 / 3.15 2.97 / 3.67 2.6 / 3.2 • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: MSZ-FA25/35, MSZ-GA22/25/35/50 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50 SLZ-KA25/35/50 Capacity (kW) A 2.2 / 3.3 2.5 / 3.6 3.5 / 4.0 5.0 / 6.8 2.2 / 3.3 2.2 / 3.18 2.08 / 2.62 1.65 / 2.08 2.5 / 3.4 2.25 / 2.83 1.8 / 2.27 2.7 / 3.4 2.22 / 2.8 2.7 / 3.4 1.8 / 2.27 1.72 / 2.17 1.5 / 1.89 1.26 / 1.59 1.64 / 2.08 1.45 / 1.83 1.23 / 1.54 1.3 / 1.62 1.8 / 2.27 1.59 / 2.0 1.35 / 1.7 1.42 / 1.78 B C 2.2 / 3.3 2.5 / 3.18 3.32 / 4.18 3.75 / 4.72 2.5 / 3.4 3.15 / 3.97 3.6 / 4.53 2.7 / 3.4 3.18 / 4.0 2.7 / 3.4 1.8 / 2.27 1.72 / 2.17 1.5 / 1.89 1.26 / 1.59 1.88 / 2.36 1.65 / 2.07 1.39 / 1.75 2.05 / 2.59 1.8 / 2.27 1.59 / 2.0 1.35 / 1.7 1.99 / 2.51 1.8 / 2.27 1.96 / 2.46 2.4 / 3.02 2.88 / 3.62 1.88 / 2.36 2.3 / 2.9 2.78 / 3.51 2.05 / 2.59 1.8 / 2.27 2.22 / 2.8 2.7 / 3.4 1.99 / 2.51 Total 2.2 (1.4-3.0) / 3.3 (1.2-4.2) 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 3.5 (1.5-4.3) / 4.0 (1.2-4.8) 5.0 (1.6-5.6) / 6.8 (1.4-8.2) 4.4 (2.0-5.4) / 6.6 (1.8-7.2) 4.7 (2.0-5.8) / 6.8 (1.8-8.7) 5.4 (2.0-6.8) / 6.8 (1.8-9.0) 5.4 (2.0-6.8) / 6.8 (1.8-9.0) 5.0 (2.0-6.0) / 6.8 (1.8-9.0) 5.4 (2.0-6.8) / 6.8 (1.8-9.0) 5.4 (2.0-6.8) / 6.8 (1.8-9.0) 5.4 (2.0-6.8) / 6.8 (1.8-9.0) 5.4 (2.0-6.8) / 6.8 (1.8-9.0) 5.4 (2.0-6.8) / 6.8 (1.9-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) 5.4 (2.9-6.8) / 6.8 (2.6-9.0) MXZ-4A71VA Combination Model 22 25 35 50 60 22+22 22+25 22+35 22+50 22+60 25+25 25+35 25+50 25+60 35+35 35+50 35+60 50+50 50+60 60+60 22+22+22 22+22+25 22+22+35 22+22+50 22+22+60 22+25+25 22+25+35 22+25+50 22+25+60 22+35+35 22+35+50 22+35+60 22+50+50 25+25+25 25+25+35 25+25+50 25+25+60 25+35+35 25+35+50 25+35+60 25+50+50 35+35+35 35+35+50 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+50 22+22+25+25 22+22+25+35 22+22+25+50 22+22+35+35 22+25+25+25 22+25+25+35 22+25+25+50 22+25+35+35 25+25+25+25 25+25+25+35 25+25+25+50 25+25+35+35 Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 2.2 / 3.3 2.5 / 3.6 3.5 / 4.0 5.0 / 7.2 6.0 / 7.9 2.2 / 3.3 2.2 / 3.23 2.2 / 2.82 2.08 / 2.63 1.82 / 2.31 2.5 / 3.6 2.5 / 3.17 2.27 / 2.87 2.0 / 2.53 3.4 / 4.3 2.8 / 3.54 2.51 / 3.17 3.4 / 4.3 3.09 / 3.91 3.4 / 4.3 2.2 / 2.87 2.2 / 2.74 1.98 / 2.39 1.66 / 2.01 1.5 / 1.82 2.16 / 2.62 1.91 / 2.31 1.61 / 1.95 1.46 / 1.77 1.7 / 2.06 1.46 / 1.77 1.34 / 1.62 1.28 / 1.56 2.36 / 2.86 2.09 / 2.53 1.78 / 2.15 1.61 / 1.95 1.86 / 2.26 1.61 1.95 1.48 / 1.79 1.42 / 1.72 2.36 / 2.86 2.07 / 2.51 1.77 / 2.15 1.72 / 2.08 1.55 / 1.87 1.35 / 1.63 1.66 / 2.01 1.5 / 1.82 1.31 / 1.59 1.37 / 1.66 1.61 / 1.94 1.46 / 1.77 1.29 / 1.56 1.34 / 1.62 1.77 / 2.15 1.61 / 1.95 1.42 / 1.72 1.48 / 1.79 B 2.2 / 3.3 2.5 / 3.67 3.5 / 4.48 4.72 / 5.97 4.98 / 6.29 2.5 / 3.6 3.5 / 4.43 4.53 / 5.73 4.8 / 6.07 3.4 / 4.3 4.0 / 5.06 4.29 / 5.43 3.4 / 4.3 3.71 / 4.69 3.4 / 4.3 2.2 / 2.87 2.2 / 2.74 1.98 / 2.39 1.66 / 2.01 1.5 / 1.82 2.47 / 2.99 2.16 / 2.62 1.83 / 2.22 1.66 / 2.01 2.7 / 3.27 2.32 / 2.81 2.12 / 2.57 2.91 / 3.52 2.36 / 2.86 2.09 / 2.53 1.78 / 2.15 1.61 / 1.95 2.62 / 3.17 2.26 / 2.74 2.07 / 2.51 2.84 / 3.44 2.36 / 2.86 2.07 / 2.51 1.77 / 21.5 1.72 / 2.08 1.55 / 1.87 1.35 / 1.63 1.66 / 2.01 1.5 / 1.82 1.31 / 1.59 1.37 / 1.66 1.83 / 2.22 1.66 / 2.01 1.45 / 1.76 1.52 / 1.84 1.77 / 2.15 1.61 / 1.95 1.42 / 1.72 1.48 / 1.79 MSZ-FA25/35, MSZ-GA22/25/35/50/60 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60 SLZ-KA25/35/50 Capacity (kW) C 2.2 / 2.87 2.5 / 3.12 3.14 / 3.82 3.78 / 4.58 4.1 / 4.96 2.47 / 2.99 3.03 / 3.67 3.66 / 4.43 3.98 / 4.82 2.7 / 3.27 3.32 / 4.02 3.64 / 4.41 2.91 / 3.52 2.36 / 2.86 2.92 / 2.53 3.54 / 4.3 3.88 / 4.68 2.62 / 3.17 3.23 / 3.91 3.55 / 4.3 2.84 / 3.44 2.36 / 2.86 2.96 / 3.58 1.77 / 2.15 1.72 / 2.08 1.55 / 1.87 1.35 / 1.63 1.89 / 2.29 1.71 / 2.07 1.5 / 1.81 2.18 / 2.64 1.83 / 2.22 1.66 / 2.01 1.45 / 1.76 2.12 / 2.57 1.77 / 2.15 1.61 / 1.95 1.42 / 1.72 2.07 / 2.51 D 1.77 / 2.15 1.94 / 2.36 2.45 / 2.98 3.05 / 3.71 1.89 / 2.29 2.39 / 2.89 2.98 / 3.61 2.18 / 2.64 1.83 / 2.22 2.32 2.81 2.91 / 3.52 2.12 / 2.57 1.77 / 2.15 2.27 / 2.75 2.84 / 3.44 2.07 / 2.51 Total 2.2 (1.4-3.0) / 3.3 (1.2-4.2) 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 3.5 (1.5-4.3) / 4.0 (1.2-4.8) 5.0 (1.6-5.6) / 7.2 (1.4-8.2) 6.0 (1.6-6.0) / 7.9 (1.4-8.6) 4.4 (2.0-5.4) / 6.6 (1.8-7.2) 4.7 (2.0-5.8) / 6.9 (1.8-8.7) 5.7 (2.0-6.6) / 7.3 (1.8-9.0) 6.8 (2.0-7.1) / 8.6(1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.8-9.0) 5.0 (2.0-6.0) / 7.2 (1.8-9.0) 6.0 (2.0-7.1) / 7.6 (1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.8-9.0) 6.8 (2.0-7.1) / 8.6 (1.9-9.0) 6.8 (2.0-7.1) / 8.6 (1.9-9.0) 6.8 (2.0-7.1) / 9.0 (1.8-10.1) 6.6 (2.9-8.1) / 8.6 (2.6-9.0) 6.9 (2.9-8.3) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (2.9-8.5) / 8.6 (2.6-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 7.1 (3.7-8.8) / 8.6 (3.4-9.0) 25 MXZ-4A80VA Combination Model Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating 22 25 35 50 60 71 22+22 22+25 22+35 22+50 22+60 22+71 25+25 25+35 25+50 25+60 25+71 35+35 35+50 35+60 35+71 50+50 50+60 50+71 60+60 60+71 22+22+22 22+22+25 22+22+35 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+50 22+25+60 22+25+71 22+35+35 22+35+50 22+35+60 22+35+71 22+50+50 22+50+60 22+50+71 25+25+25 25+25+35 25+25+50 25+25+60 25+25+71 25+35+35 25+35+50 25+35+60 25+35+71 25+50+50 25+50+60 35+35+35 35+35+50 35+35+60 35+35+71 35+50+50 35+50+60 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 26 • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 2.2 / 3.3 2.5 / 3.6 3.4 / 4.0 5.0 / 7.2 6.0 / 7.9 7.1 / 8.6 2.3 / 3.3 2.1 / 3.23 2.1 / 2.82 2.04 / 2.52 1.75 / 2.52 1.66 / 2.22 2.5 / 3.6 2.52 / 3.17 2.5 / 3.0 2.11 / 2.76 2.01 / 2.45 3.4 / 4.0 3.1 / 3.87 2.61 / 3.46 2.51 / 3.1 3.95 / 4.7 3.42 / 4.27 3.27 / 3.88 4.0 / 4.7 3.84 / 4.31 2.3 / 2.9 2.16 / 2.84 2.07 / 2.62 1.72 / 2.2 1.46 / 1.99 1.4 / 1.8 2.04 / 2.72 1.93 / 2.52 1.62 / 2.13 1.4 / 1.93 1.33 / 1.75 1.77 / 2.25 1.49 / 1.93 1.3 / 1.77 1.24 / 1.62 1.3 / 1.7 1.14 / 1.57 1.09 / 1.45 2.36 / 3.0 2.32 / 2.76 1.97 / 2.35 1.71 / 2.14 1.63 / 1.94 2.15 / 2.48 1.84 / 2.14 1.6 / 1.96 1.53 / 1.79 1.6 / 1.88 1.41 / 1.74 2.65 / 3.13 2.28 / 2.74 2.0 / 2.53 1.92 / 2.33 2.0 / 2.44 1.77 / 2.27 1.95 / 2.35 1.83 / 2.27 1.68 / 2.05 1.43 / 1.78 1.24 / 1.64 1.19 / 1.51 1.72 / 2.2 1.59 / 1.99 B 2.3 / 3.3 2.7 / 3.67 3.6 / 4.48 5.25 / 6.88 6.0 / 6.88 6.19 / 7.18 2.5 / 3.6 3.37 / 4.43 5.0 / 6.0 5.64 / 6.64 5.84 / 6.98 3.4 / 4.0 4.65 / 5.53 5.24 / 5.94 5.44 / 6.3 3.95 / 4.7 4.57 / 5.37 4.72 / 5.52 4.0 / 4.7 4.16 / 5.09 2.3 / 2.9 2.16 / 2.81 2.07 / 2.62 1.72 / 2.2 1.46 / 1.99 1.4 / 1.8 2.62 / 3.09 2.49 / 2.87 2.09 / 2.42 1.8 / 2.2 1.71 / 1.99 3.04 / 3.58 2.56 / 3.07 2.23 / 2.81 2.13 / 2.57 3.34 / 3.85 2.93 / 3.56 2.82 / 3.29 2.36 / 3.0 2.32 / 2.76 1.97 / 2.35 1.71 / 2.14 1.63 / 1.94 2.85 / 3.46 2.46 / 2.99 2.13 / 2.74 2.04 / 2.51 3.2 / 3.76 2.82 / 3.48 2.65 / 3.13 2.28 / 2.74 2.0 / 2.53 1.92 / 2.33 3.0 / 3.48 2.66 / 3.24 1.95 / 2.35 1.83 / 2.27 1.68 / 2.05 1.43 / 1.78 1.24 / 1.64 1.19 / 1.51 1.72 / 2.2 1.59 / 1.99 MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 Capacity (kW) C 2.3 / 2.9 2.16 / 3.19 3.55 / 4.16 4.41 / 5.0 5.03 / 5.42 5.2 / 5.8 2.62 / 3.09 3.33 / 4.01 4.18 / 4.85 4.8 / 5.27 4.95 / 5.66 3.04 / 3.58 3.84 / 4.39 4.46 / 4.82 4.62 / 5.21 3.34 / 3.85 3.91 / 4.27 4.07 / 4.67 2.36 / 3.0 3.11 / 3.87 3.95 / 4.7 4.57 / 5.13 4.72 / 5.52 2.85 / 3.46 3.69 / 4.27 4.26 / 4.7 4.42 / 5.09 3.2 / 3.76 3.76 / 4.18 2.65 / 3.13 3.42 / 3.92 4.0 / 4.34 4.16 / 4.74 3.0 / 3.48 3.55 / 3.89 1.95 / 2.35 1.83 / 2.27 1.68 / 2.05 1.43 / 1.78 1.24 / 1.64 1.19 / 1.51 2.2 / 2.5 2.04 / 2.26 D 1.95 / 2.35 2.36 / 2.59 2.91 / 3.25 3.69 / 4.06 4.26 / 4.48 4.42 / 4.87 2.2 / 2.5 2.72 / 3.16 Total 2.3 (1.4-3.0) / 3.3 (1.2-4.2) 2.5 (1.4-3.3) / 3.6 (1.2-4.5) 3.4 (1.5-4.3) / 4.0 (1.2-4.8) 5.0 (1.6-5.6) / 7.2 (1.4-8.2) 6.0 (1.6-6.6) / 7.9 (1.4-8.6) 7.1 (1.6-7.4) / 8.6 (1.4-8.6) 4.6 (2.0-5.4) / 6.6 (1.8-7.2) 4.8 (2.0-5.8) / 6.9 (1.8-8.7) 5.7 (2.0-6.6) / 7.3 (1.8-9.2) 7.3 (2.0-7.7) / 8.9 (1.8-9.9) 7.75 (2.0-8.0) / 9.4 (1.8-9.9) 7.85 (2.0-8.2) / 9.4 (1.8-9.9) 5.0 (2.0-6.2) / 7.2 (1.8-9.1) 5.9 (2.0-7.3) / 7.6 (1.8-9.5) 7.5 (2.0-8.5) / 9.0 (1.8-10.1) 7.75 (2.0-8.6) / 9.4 (1.8-10.1) 7.85 (2.0-8.7) / 9.4 (1.8-10.1) 6.8 (2.0-8.8) / 8.0 (1.8-9.8) 7.75 (2.0-8.8) / 9.4 (1.8-10.5) 7.85 (2.0-8.8) / 9.4 (1.8-10.5) 7.95 (2.0-8.8) / 9.4 (1.8-10.5) 7.9 (2.1-8.8) / 9.4 (1.9-11.2) 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 8.0 (2.1-8.8) / 9.4 (1.9-11.2) 8.7 (2.9-8.1) / 8.6 (2.6-10.6) 7.1 (2.9-8.6) / 8.8 (2.6-11.1) 7.7 (2.9-9.0) / 9.4 (2.6-11.6) 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 7.95 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 7.3 (2.9-8.9) / 8.9 (2.6-11.6) 7.75 (2.9-9.0) / 9.4 (2.6-11.6) 7.9 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 7.9 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 7.1 (2.9-9.0) / 9.0 (2.6-11.6) 7.75 (2.9-9.0) / 9.4 (2.6-11.6) 7.9 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.6-11.6) 7.85 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 7.95 (2.9-9.0) / 9.4 (2.6-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 8.0 (2.9-9.0) / 9.4 (2.7-11.6) 7.8 (3.7-9.2) / 9.4 (3.4-11.6) 7.85 (3.7-9.2) / 9.4 (3.4-11.6) 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 7.85 (3.7-9.2) / 9.4 (3.4-11.6) 7.95 (3.7-9.2) / 8.6 (3.4-9.0) MXZ-4A80VA Combination Model 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+50 22+22+35+60 22+22+50+50 22+25+25+25 22+25+25+35 22+25+25+50 22+25+25+60 22+25+35+35 22+25+35+50 22+25+35+60 22+35+35+35 22+35+35+50 25+25+25+25 25+25+25+35 25+25+25+50 25+25+25+60 25+25+35+35 25+25+35+50 25+35+35+35 35+35+35+35 Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 1.36 / 1.74 1.19 / 1.6 1.14 / 1.48 1.47 / 1.81 1.27 / 1.6 1.12 / 1.49 1.12 / 1.44 1.62 / 2.14 1.5 / 1.93 1.3 / 1.7 1.14 / 1.57 1.4 / 1.77 1.21 / 1.57 1.07 / 1.46 1.3 / 1.63 1.14 / 1.45 1.97 / 2.35 1.84 / 2.14 1.6 / 1.88 1.41 / 1.74 1.56 / 1.96 1.5 / 1.74 1.6 / 1.81 2.0 / 2.35 B 1.36 / 1.74 1.19 / 1.6 1.14 / 1.48 1.47 / 1.81 1.27 / 1.6 1.12 / 1.49 1.12 / 1.44 2.09 / 2.42 1.93 / 2.2 1.67 / 1.93 1.46 / 1.78 1.8 / 2.01 1.56 / 1.78 1.38 / 1.65 2.23 / 2.59 1.95 / 2.32 1.97 / 2.35 1.84 / 2.14 1.6 / 1.88 1.41 / 1.74 1.75 / 1.96 1.5 / 1.74 2.13 / 2.53 2.0 / 2.35 MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 Capacity (kW) C 1.75 / 1.97 1.53 / 1.83 1.46 / 1.68 2.52 / 2.89 2.18 / 2.55 1.92 / 2.37 2.88 / 3.26 2.09 / 2.42 1.93 / 2.2 1.67 / 1.93 1.46 / 1.78 2.4 / 2.81 2.08 / 2.49 1.84 / 2.32 2.23 / 2.59 1.95 / 2.32 1.97 / 2.35 1.84 / 2.14 1.6 / 1.88 1.41 / 1.74 2.34 / 2.74 2.0 / 2.44 2.13 / 2.53 2.0 / 2.35 D 3.51 / 3.95 4.08 / 4.37 4.24 / 4.76 2.52 / 2.89 3.27 / 3.65 3.84 / 4.05 2.88 / 3.26 2.09 / 2.42 2.59 / 3.07 3.34 / 3.85 3.91 / 4.27 2.4 / 2.81 3.13 / 3.56 3.69 / 3.97 2.23 / 2.59 2.93 / 3.31 1.97 / 2.35 2.46 / 2.98 3.2 / 3.76 3.76 / 4.18 2.34 / 2.74 3.0 / 3.48 2.13 / 2.53 2.0 / 2.35 Total 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 7.9 (3.7-9.2) / 9.4 (3.4-11.6) 7.95 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.5-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 8.0 (3.7-9.2) / 9.4 (3.4-11.6) 27 Series Inverter Multi Split Systems for up to 8 Indoor Units • Wide selection of indoor units in Highlights • Comfortable room temperature all year round • Inverter-controlled, power-saving scroll compressors for whisperquiet operation and minimum vibrations • Inverter technology saves power and ensures perfect climate comfort • Outdoor unit pre-charged with R410A refrigerant for up to 40 m piping length • Unobtrusive outdoor installation – only one outdoor unit required for up to eight indoor units Note: The Multi Split Systems of the MXZ series operate in either cooling or heating mode. At least two indoor units must be connected. wall mounted, floor standing, ceiling suspended, ducted and ceiling cassette versions. Support for connection of both M series indoor units and Mr. Slim series indoor units with the new A-Control system, see page 38 • Indoor units with different capacities can be combined to suit individual room requirements • Special function for saving your ‘personal climate settings’ • Automatic restart in case of power failures • Winter kit for cooling operation down to -5°C, or down to -10°C with wind-shielded installation • PAC-AK30/50BC branch box required, see page 29 MXZ INVERTER MULTI-SPLIT OUTDOOR UNIT Outdoor unit Cooling Capacity Heating Capacity Energy Effiziency Range Airflow Noise Weight Dimensions Max. Pipe Length Max. Pipe Length Controller/Indoor Units Max. Height Difference Indoor Units/Controller Charge R410A* Pipe Size Pipe Size to the Indoor Units Electrical Supply (V, Phase, Hz) Max. Capacity (kW) (kW) Cooling/Heating (m³/h) dB(A) (kg) (mm) Width Depth Heigth (m) (m) (m) (kg) Ø (mm) Liquid Gas Ø (mm) Liquid Gas (kW) Running Current Recommend Safety Fuse Connectable Indoor Units (Number) Cooling Heating Cooling Heating (A) * Charged for 40 m pipe length, see page 37, too. 28 MXZ-8A140VA 14.0 16.0 A/A 6000 47 128 950 330 1350 115 60 12/15 8.5 10 16 3x6 / 5x6 3x10 / 4x10 / 1x12 220-240, 1, 50 3.79 3.90 16.55 17.05 40 2-8 Series Branch Boxes for Multi Split Systems PAC-AK30/50BC Highlights • PAC-AK30BC and PAC-AK50BC branch boxes can also be installed outdoors if indoor installation is not possible. An optional weatherproof cover is required for outdoor installation • Standard T-branch fittings can be used Accessories • PAC-AK350CVR-E weatherproof cover for outdoor installation, see page 36 BRANCH BOX FOR OUTDOOR UNIT MXZ-8A140VA Branch Box Weight Dimensions (mm) Connectable Indoor Units (Number) (kg) Width Depth Height PAC-AK30BC 8.1 450 280 198 1-3 PAC-AK50BC 9.3 450 280 198 1-5 29 MXZ-8A140VA Combination Model Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating 22 25 35 50 60 71 22+22 22+25 22+35 22+50 22+60 22+71 25+25 25+35 25+50 25+60 25+71 35+35 35+50 35+60 35+71 50+50 50+60 50+71 60+60 60+71 71+71 22+22+22 22+22+25 22+22+35 22+22+50 22+22+60 22+22+71 22+25+25 22+25+35 22+25+50 22+25+60 22+25+71 22+35+35 22+35+50 22+35+60 22+35+71 22+50+50 22+50+60 22+50+71 22+60+60 22+60+71 22+71+71 25+25+25 25+25+35 25+25+50 25+25+60 25+25+71 25+35+35 25+35+50 25+35+60 25+35+71 25+50+50 25+50+60 25+50+71 25+60+60 25+60+71 25+71+71 35+35+35 35+35+50 35+35+60 35+35+71 35+50+50 35+50+60 30 • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 2.2 / 3.3 2.5 / 3.6 3.5 / 4.0 5.0 / 7.2 6.0 / 7.9 7.1 / 8.6 2.2 / 2.5 2.2 / 2.53 2.2 / 2.51 2.2 / 2.51 2.2 / 2.52 2.2 / 2.51 2.5 / 2.85 2.5 / 2.88 2.5 / 2.87 2.5 / 2.85 2.5 / 2.86 3.35 / 4.0 3.5 / 3.99 3.5 / 4.02 3.5 / 4.0 5.5 / 5.7 5.0 / 5.73 5.0 / 5.7 6.0 / 6.85 6.0 / 6.87 7.1 / 8.0 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.51 2.2 / 2.51 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.15 / 2.46 2.17 / 2.48 2.01 / 2.3 1.88 / 2.14 2.5 / 2.86 2.5 / 2.85 2.5 / 2.85 2.5 / 2.86 2.5 / 2.85 2.5 / 2.86 2.5 / 2.86 2.5 / 2.85 2.5 / 2.86 2.5 / 2.86 2.5 / 2.85 2.4 / 2.74 2.41 / 2.76 2.24 / 2.56 2.1 / 2.4 3.5 / 4.0 3.5 / 4.0 3.5 / 4.01 3.48 / 3.97 3.5 / 3.99 3.38 / 3.86 B C 2.2 / 2.5 2.5 / 2.87 3.5 / 3.99 5.0 / 5.69 6.0 / 6.88 7.1 / 8.09 2.5 / 2.85 3.5 / 4.02 5.0 / 5.73 6.0 / 6.85 7.1 / 8.14 3.5 / 4.0 5.0 / 5.71 6.0 / 6.88 7.1 / 8.1 5.0 / 5.7 6 / 6.87 7.1 / 8.1 6.0 / 6.85 7.1 / 8.13 7.1 / 8.0 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.5 / 2.85 2.5 / 2.87 2.5 / 2.86 2.5 / 2.85 2.5 / 2.86 3.5 / 3.99 3.5 / 3.99 3.5 / 4.01 3.5 / 3.99 5.0 / 5.7 5.0 / 5.72 4.9 / 5.59 5.92 / 6.76 5.49 / 6.27 6.06 / 6.93 2.5 /2.86 2.5 / 2.85 2.5 / 2.85 2.5 / 2.86 2.5 / 2.85 3.5 / 4.02 3.5 / 4.01 3.5 / 4.0 3.5 / 4.01 5.0 / 5.72 5.0 / 5.7 4.79 / 5.48 5.79 / 6.62 5.38 / 6.15 5.95 / 6.8 3.5 / 4.0 3.5 / 4.0 3.5 / 4.01 3.48 / 3.97 5.0 / 5.7 4.83 / 5.52 2.2 / 2.5 2.5 / 2.86 3.5 / 3.98 5.0 / 4.69 6.0 / 6.86 7.1 / 8.09 2.5 / 2.85 3.5 / 4.01 5.0 / 5.72 6.0 / 6.84 7.1 / 8.12 3.5 / 3.99 5.0 / 5.7 6.0 / 6.87 7.1 / 8.1 5.0 / 5.7 6.0 / 6.86 6.95 / 7.94 5.92 / 6.76 6.5 / 7.42 6.06 / 6.93 2.5 / 2.86 3.5 / 3.99 5.0 / 5.7 6.0 / 6.87 7.1 / 8.1 3.5 / 4.02 5.0 / 5.73 6.0 / 6.85 7.1 / 8.13 5.0 / 5.72 6.0 / 6.84 6.81 / 7.78 5.79 / 6.62 6.37 / 7.28 5.95 / 6.8 3.5 / 4.0 5.0 / 5.7 6.0 / 6.88 7.05 / 8.06 5.0 / 5.7 5.79 / 6.62 D MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 E Capacity (kW) F G H Total 2.2 / 3.3 2.5 / 3.6 3.5 / 4.0 5.0 / 7.2 6.0 / 7.9 7.1 / 8.6 4.4 / 5.0 4.7 / 5.4 5.7 / 6.5 7.2 / 8.2 8.2 / 9.4 9.3 / 10.6 5.0 / 5.7 6.0 / 6.9 7.5 / 8.6 8.5 / 9.7 9.6 / 11 7.0 / 8.0 8.5 / 9.7 9.5 / 10.9 10.6 / 12.1 10.0 / 11.4 11.0 / 12.6 12.1 / 13.8 12.0 / 13.7 13.1 / 15.0 14.0 / 16.0 6.6 / 7.5 6.9 / 7.9 7.9 / 9.0 9.4 / 10.7 10.4 / 11.9 11.5 / 13.1 7.2 / 8.2 8.2 / 9.4 9.7 / 11.1 10.7 / 12.2 11.8 / 13.5 9.2 / 10.5 10.7 / 12.2 11.7 / 13.4 12.8 / 14.6 12.2 / 13.9 13.2 / 15.1 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 7.5 / 8.6 8.5 / 9.7 10.0 / 11.4 11.0 / 12.6 12.1 / 13.8 9.5 / 10.9 11.0 / 12.6 12.0 / 13.7 13.1 / 15.0 12.5 / 14.3 13.5 / 15.4 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 10.5 / 12.0 12.0 / 13.7 13.0 / 14.9 14.0 / 16.0 13.5 / 15.4 14.0 / 16.0 MXZ-8A140VA Combination Model 35+50+71 35+60+60 35+60+71 35+71+71 50+50+50 50+50+60 50+50+71 50+60+60 50+60+71 60+60+60 22+22+22+22 22+22+22+25 22+22+22+35 22+22+22+50 22+22+22+60 22+22+22+71 22+22+25+25 22+22+25+35 22+22+25+50 22+22+25+60 22+22+25+71 22+22+35+35 22+22+35+50 22+22+35+60 22+22+35+71 22+22+50+50 22+22+50+60 22+22+50+71 22+22+60+60 22+22+60+71 22+25+25+25 22+25+25+35 22+25+25+50 22+25+25+60 22+25+25+71 22+25+35+35 22+25+35+50 22+25+35+60 22+25+35+71 22+25+50+50 22+25+50+60 22+25+50+71 22+25+60+60 22+25+60+71 22+35+35+35 22+35+35+50 22+35+35+60 22+35+35+71 22+35+50+50 22+35+50+60 22+35+50+71 22+35+60+60 22+50+50+50 22+50+50+60 25+25+25+25 25+25+25+35 25+25+25+50 25+25+25+60 25+25+25+71 25+25+35+35 25+25+35+50 25+25+35+60 25+25+35+71 25+25+50+50 25+25+50+60 25+25+50+71 25+25+60+60 25+25+60+71 25+35+35+35 Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 3.14 / 3.59 3.16 / 3.61 2.95 / 3.37 2.77 / 3.16 4.67 / 5.33 4.38 / 5.0 4.09 / 4.68 4.12 / 4.7 3.87 / 4.42 4.67 / 5.33 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.2 / 2.52 2.05 / 2.35 2.14 / 2.44 2.0 / 2.29 1.87 / 2.13 1.88 / 2.15 1.76 / 2.01 2.2 / 2.52 2.2 / 2.51 2.2 / 2.51 2.2 / 2.52 2.15 / 2.46 2.2 / 2.52 2.2 / 2.52 2.17 / 2.48 2.01 / 2.3 2.1 / 2.39 1.96 / 2.24 1.83 / 2.1 1.84 / 2.1 1.73 / 1.98 2.2 / 2.5 2.17 / 2.48 2.03 / 2.32 1.89 / 2.16 1.96 / 2.23 1.84 / 2.11 1.73 / 1.98 1.73 / 1.99 1.79 / 2.05 1.69 / 1.93 2.5 / 2.85 2.5 / 2.86 2.5 / 2.86 2.5 / 2.85 2.4 / 2.74 2.5 / 2.85 2.5 / 2.85 2.41 / 2.76 2.24 / 2.56 2.33 / 2.67 2.19 / 2.5 2.05 / 2.34 2.06 / 2.35 1.93 / 2.21 2.5 / 2.87 B 4.49 / 5.13 5.42 / 6.19 5.06 / 5.78 5.62 / 6.42 4.67 / 5.33 4.38 / 5.0 4.09 / 4.68 4.94 / 5.65 4.64 / 5.3 4.67 / 5.33 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.2 / 2.52 2.05 / 2.35 2.14 / 2.44 2.0 / 2.29 1.87 / 2.13 1.88 / 2.15 1.76 / 2.01 2.5 / 2.86 2.5 / 2.85 2.5 / 2.85 2.5 / 2.86 2.45 / 2.8 2.5 / 2.86 2.5 / 2.86 2.46 / 2.82 2.29 / 2.61 2.38 / 2.72 2.23 / 2.55 2,08 / 2,38 2.1 / 2.4 1.97 / 2.25 3.5 / 4.0 3.45 / 3.94 3.22 / 3.68 3.01 / 3.44 3.12 / 3.57 2.93 / 3.35 2.75 / 3.15 2.77 / 3.16 4.07 / 4.65 3.85 / 4.4 2.5 / 2.85 2.5 / 2.86 2.5 / 2.86 2.5 / 2.85 2.4 / 2.74 2.5 / 2.85 2.5 / 2.85 2.41 / 2.76 2.24 / 2.56 2.33 / 2.67 2.19 / 2.5 2.05 / 2.34 2.06 / 2.35 1.93 / 2.21 3.5 / 4.01 C 6.37 / 7.28 5.42 / 6.19 5.99 / 6.84 5.62 / 6.42 4.67 / 5.33 5.25 / 6.0 5.81 / 6.64 4.94 / 5.65 5.49 / 6.28 4.67 / 5.33 2.2 / 2.52 2.2 / 2.51 2.2 / 2.5 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.5 / 2.85 2.5 / 2.86 2.5 / 2.86 2.5 / 2.85 2.5 / 2.86 3.5 / 3.99 3.5 / 3.99 3.5 / 4.0 3.27 / 3.73 4.86 / 5.56 4.55 / 5.19 4.24 / 4.85 5.12 / 5.85 4.8 / 5.49 2.5 / 2.86 2.5 / 2.85 2.5 / 2.85 2.5 / 2.86 2.45 / 2.8 3.5 / 4.01 3.5 / 4.0 3.45 / 3.94 3.2 / 3.66 4.76 / 5.44 4.46 / 5.1 4,17 / 4,76 5.03 / 5.75 4.72 / 5.39 3.5 / 4.0 3.45 / 3.94 3.22 / 3.68 3.01 / 3.44 4.46 / 5.1 4.19 / 4.79 3.93 / 4.49 4.75 / 5.42 4.07 / 4.65 3.85 / 4.4 2.5 / 2.85 2.5 / 2.86 2.5 / 2.86 2.5 / 2.85 2.4 / 2.74 3.5 / 4.0 3.5 / 3.99 3.38 / 3.86 3,14 / 3,59 4.67 / 5.33 4.38 / 5.0 4.09 / 4.68 4.94 / 5.65 4.64 / 5.3 3.5 / 4.01 D 2.2 / 2.52 2.5 / 2.86 3.5 / 3.99 5.0 / 5.73 6.0 / 6.86 7.1 / 8.14 2.5 / 2.85 3.5 / 4.0 5.0 / 5.71 6.0 / 6.83 7.1 / 8.11 3.5 / 3.99 5.0 / 5.69 6.0 / 6.86 6.63 / 7.57 4.86 / 5.56 5.45 / 6.23 6.02 / 6.88 5.12 / 5.85 5.68 / 6.49 2.5 / 2.86 3.5 / 3.99 5.0 / 5.69 6.0 / 6.86 6.95 / 7.94 3.5 / 4.01 5.0 / 5.72 5.92 / 6.76 6.5 / 7.42 4.76 / 5.44 5.35 / 6.11 5.92 / 6.76 5.03 / 5.75 5.58 / 6.38 3.5 / 4.0 4.93 / 5.63 5.53 / 6.32 6.09 / 6.96 4.46 / 5.1 5.03 / 5.75 5.58 / 6.38 4.75 / 5.42 4.07 / 4.65 4.61 / 5.27 2.5 / 2.85 3.5 / 4.01 5.0 / 5.72 6.0 / 6.84 6.8 / 7.78 3.5 / 4.0 5.0 / 5.7 5.79 / 6.62 6.37 / 7.28 4.67 / 5.33 5.24 / 6.0 5.81 / 6.64 4.94 / 5.65 5.49 / 6.28 3.5 / 4.01 MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 E Capacity (kW) F G H Total 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 8.8 / 10.1 9.1 / 10.4 10.1 / 11.5 11.6 / 13.3 12.6 / 14.4 13.7 / 15.7 9.4 / 10.7 10.4 / 11.9 11.9 / 13.6 12.9 / 14.7 14.0 / 16.0 11.4 / 13.0 12.9 / 14.7 13.9 / 15.9 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 9.7 / 11.1 10.7 / 12.2 12.2 / 13.9 13.2 / 15.1 14.0 / 16.0 11.7 / 13.4 13.2 / 15.1 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 12.7 / 14.5 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 10.0 / 11.4 11.0 / 12.6 12.5 / 14.3 13.5 / 15.4 14.0 / 16.0 12.0 / 13.7 13.5 / 15.4 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 13.0 / 14.9 31 MXZ-8A140VA Combination Model 25+35+35+50 25+35+35+60 25+35+35+71 25+35+50+50 25+35+50+60 25+35+50+71 25+35+60+60 25+50+50+50 25+50+50+60 35+35+35+35 35+35+35+50 35+35+35+60 35+35+35+71 35+35+50+50 35+35+50+60 35+50+50+50 22+22+22+22+22 22+22+22+22+25 22+22+22+22+35 22+22+22+22+50 22+22+22+22+60 22+22+22+22+71 22+22+22+25+25 22+22+22+25+35 22+22+22+25+50 22+22+22+25+60 22+22+22+25+71 22+22+22+35+35 22+22+22+35+50 22+22+22+35+60 22+22+22+35+71 22+22+22+50+50 22+22+22+50+60 22+22+25+25+25 22+22+25+25+35 22+22+25+25+50 22+22+25+25+60 22+22+25+25+71 22+22+25+35+35 22+22+25+35+50 22+22+25+35+60 22+22+25+35+71 22+22+25+50+50 22+22+25+50+60 22+22+35+35+35 22+22+35+35+50 22+22+35+35+60 22+22+35+35+71 22+22+35+50+50 22+25+25+25+25 22+25+25+25+35 22+25+25+25+50 22+25+25+25+60 22+25+25+25+71 22+25+25+35+35 22+25+25+35+50 22+25+25+35+60 22+25+25+35+71 22+25+25+50+50 22+25+25+50+60 22+25+35+35+35 22+25+35+35+50 22+25+35+35+60 22+25+35+50+50 22+35+35+35+35 22+35+35+35+50 25+25+25+25+25 25+25+25+25+35 25+25+25+25+50 32 Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 2.41 / 2.76 2.26 / 2.58 2.11 / 2.41 2.18 / 2.5 2.06 / 2.35 1.93 / 2.21 1.94 / 2.22 2.0 / 2.29 1.89 / 2.16 3.5 / 4.0 3.16 / 3.61 2.97 / 3.39 2.78 / 3.18 2.88 / 3.29 2.72 / 3.11 2.65 / 3.03 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.52 2.08 / 2.38 1.94 / 2.21 2.2 / 2.52 2.2 / 2.51 2.18 / 2.5 2.04 / 2.33 1.9 / 2.17 2.2 / 2.51 2.04 / 2.33 1.91 / 2.19 1.79 / 2.05 1.86 / 2.12 1.75 / 2.0 2.2 / 2.51 2.2 / 2.51 2.14 / 2.44 2.0 / 2.29 1.87 / 2.13 2.2 / 2.52 2.0 / 2.29 1.88 / 2.15 1.76 / 2.01 1.82 / 2.08 1.72 / 1.97 2.06 / 2.36 1.88 / 2.15 1.77 / 2.02 1.66 / 1.9 1.72 / 1.97 2.2 / 2.5 2.2 / 2.52 2.1 / 2.39 1.96 / 2.24 1.83 / 2.1 2.17 / 2.48 1.96 / 2.24 1.84 / 2.11 1.73 / 1.98 1.79 / 2.04 1.69 / 1.93 2.03 / 2.32 1.84 / 2.11 1.74 / 1.99 1.69 / 1.92 1.9 / 2.16 1.74 / 1.99 2.5 / 2.86 2.5 / 2.85 2.33 / 2.67 B 3.38 / 3.86 3.16 / 3.61 2.95 / 3.37 3.06 / 3.5 2.88 / 3.29 2.71 / 3.09 2.72 / 3.11 4.0 / 4.57 3.78 / 4.32 3.5 / 4.0 3.16 / 3.61 2.97 / 3.39 2.78 / 3.18 2.88 / 3.29 2.72 / 3.11 3.78 / 4.32 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.52 2.08 / 2.38 1.94 / 2.21 2.2 / 2.52 2.2 / 2.51 2.18 / 2.5 2.04 / 2.33 1.9 / 2.17 2.2 / 2.51 2.04 / 2.33 1.91 / 2.19 1.79 / 2.05 1.86 / 2.12 1.75 / 2.0 2.2 / 2.51 2.2 / 2.51 2.14 / 2.44 2.0 / 2.29 1.87 / 2.13 2.2 / 2.52 2.0 / 2.29 1.88 / 2.15 1.76 / 2.01 1.82 / 2.08 1.72 / 1.97 2.06 / 2.36 1.88 / 2.15 1.77 / 2.02 1.66 / 1.9 1.72 / 1.97 2.5 / 2.85 2.5 / 2.86 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 2.46 / 2.82 2.23 / 2.55 2.1 / 2.4 1.97 / 2.25 2.03 / 2.33 1.92 / 2.2 2.3 / 2.63 2.1 / 2.4 1.98 / 2.26 1.92 / 2.2 3.02 / 3.46 2.77 / 3.16 2.5 / 2.86 2.5 / 2.85 2.33 / 2.67 C 3.38 / 3.86 3.16 / 3.61 2.95 / 3.37 4.38 / 5.0 4.12 / 4.71 3.87 / 4.42 4.67 / 5.33 4.0 / 4.57 3.78 / 4.32 3.5 / 4.0 3.16 / 3.61 2.97 / 3.39 2.78 / 3.18 4.12 / 4.71 3.89 / 4.44 3.78 / 4.32 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.52 2.08 / 2.38 1.94 / 2.21 2.2 / 2.52 2.2 / 2.51 2.18 / 2.5 2.04 / 2.33 1.9 / 2.17 2.2 / 2.51 2.04 / 2.33 1.91 / 2.19 1.79 / 2.05 1.86 / 2.12 1.75 / 2.0 2.5 / 2.86 2.5 / 2.85 2.43 / 2.78 2.27 / 2.6 2.12 / 2.42 2.5 / 2.86 2.27 / 2.6 2.13 / 2.44 2.0 / 2.29 2.07 / 2.37 1.96 / 2.23 3.29 / 3.76 2.99 / 3.41 2.82 / 3.22 2.65 / 3.03 2.74 / 3.12 2.5 / 2.85 2.5 / 2.86 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 2.46 / 2.82 2.23 / 2.55 2.1 / 2.4 1.97 / 2.25 2.03 / 2.33 1.92 / 2.2 3.22 / 3.68 2.93 / 3.35 2.77 / 3.16 2.69 / 3.08 3.02 / 3.46 2.77 / 3.16 2.5 / 2.86 2.5 / 2.85 2.33 / 2.67 D 4.83 / 5.52 5.42 / 6.19 5.99 / 6.84 4.38 / 5.0 4.94 / 5.65 5.49 / 6.28 4.67 / 5.33 4.0 / 4.57 4.54 / 5.19 3.5 / 4.0 4.52 / 5.16 5.09 / 5.82 5.65 / 6.45 4.12 / 4.71 4.67 / 5.33 3.78 / 4.32 2.2 / 2.52 2.2 / 2.51 2.2 / 2.52 2.2 / 2.52 2.08 / 2.38 1.94 / 2.21 2.5 / 2.87 2.5 / 2.86 2.48 / 2.84 2.32 / 2.65 2.16 / 2.47 3.5 / 3.98 3.25 / 3.71 3.04 / 3.48 2.85 / 3.26 4.21 / 4.82 3.98 / 4.55 2.5 / 2.86 2.5 / 2.85 2.43 / 2.78 2.27 / 2.6 2.12 / 2.42 3.5 / 4.0 3.18 / 3.64 2.99 / 3.41 2.8 / 3.2 4.14 / 4.73 3.91 / 4.47 3.29 / 3.76 2.99 / 3.41 2.82 / 3.22 2.65 / 3.03 3.91 / 4.47 2.5 / 2.85 2.5 / 2.86 2.38 / 2.72 2.23 / 2.55 2.08 / 2.38 3.45 / 3.94 3.12 / 3.57 2.93 / 3.35 2.75 / 3.15 4.07 / 4.65 3.85 / 4.4 3.22 / 3.68 2.93 / 3.35 2.77 / 3.16 3.85 / 4.4 3.02 / 3.46 2.77 / 3.16 2.5 / 2.86 2.5 / 2.85 2.33 / 2.67 MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 E Capacity (kW) F 2.2 / 2.52 2.5 / 2.85 3.5 / 4.01 5.0 / 5.72 5.68 / 6.48 6.24 / 7.14 2.5 / 2.87 3.5 / 4.0 4.96 / 5.66 5.56 / 6.36 6.14 / 7.01 3.5 / 3.98 4.63 / 5.3 5.22 / 5.95 5.78 / 6.59 4.21 / 4.82 4.77 / 5.45 2.5 / 2.86 3.5 / 3.98 4.86 / 5.56 5.45 / 6.22 6.02 / 6.88 3.5 / 4.0 4.55 / 5.18 5.12 / 5.85 5.68 / 6.49 4.14 / 4.73 4.69 / 5.36 3.29 / 3.76 4.26 / 4.88 4.82 / 5.52 5.37 / 6.14 3.91 / 4.47 2.5 / 2.85 3.5 / 4.0 4.76 / 5.44 5.35 / 6.11 5.92 / 6.76 3.45 / 3.94 4.46 / 5.09 5.03 / 5.74 5.58 / 6.37 4.07 / 4.65 4.62 / 5.27 3.22 / 3.68 4.19 / 4.79 4.74 / 5.42 3.85 / 4.4 3.02 / 3.46 3.95 / 4.52 2.5 / 2.86 3.5 / 3.99 4.67 / 5.32 G H Total 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 11.0 / 12.6 11.3 / 12.9 12.3 / 14.1 13.8 / 15.8 14.0 / 16.0 14.0 / 16.0 11.6 / 13.3 12.6 / 14.4 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 13.6 / 15.5 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 11.9 / 13.6 12.9 / 14.7 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 13.9 / 15.9 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 12.2 / 13.9 13.2 / 15.1 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 12.5 / 14.3 13.5 / 15.4 14.0 / 16.0 MXZ-8A140VA Combination Model 25+25+25+25+60 25+25+25+25+71 25+25+25+35+35 25+25+25+35+50 25+25+25+35+60 25+25+25+35+71 25+25+25+50+50 25+25+25+50+60 25+25+35+35+35 25+25+35+35+50 25+25+35+35+60 25+25+35+50+50 25+35+35+35+35 25+35+35+35+50 35+35+35+35+35 22+22+22+22+22+22 22+22+22+22+22+25 22+22+22+22+22+35 22+22+22+22+22+50 22+22+22+22+22+60 22+22+22+22+22+71 22+22+22+22+25+25 22+22+22+22+25+35 22+22+22+22+25+50 22+22+22+22+25+60 22+22+22+22+25+71 22+22+22+22+35+35 22+22+22+22+35+50 22+22+22+22+35+60 22+22+22+25+25+25 22+22+22+25+25+35 22+22+22+25+25+50 22+22+22+25+25+60 22+22+22+25+35+35 22+22+22+25+35+50 22+22+22+35+35+35 22+22+25+25+25+25 22+22+25+25+25+35 22+22+25+25+25+50 22+22+25+25+25+60 22+22+25+25+35+35 22+22+25+25+35+50 22+22+25+35+35+35 22+22+35+35+35+35 22+25+25+25+25+25 22+25+25+25+25+35 22+25+25+25+25+50 22+25+25+25+25+60 22+25+25+25+35+35 22+25+25+25+35+50 22+25+25+35+35+35 25+25+25+25+25+25 25+25+25+25+25+35 25+25+25+25+25+50 25+25+25+25+25+60 25+25+25+25+35+35 25+25+25+25+35+50 25+25+25+35+35+35 22+22+22+22+22+22+22 22+22+22+22+22+22+25 22+22+22+22+22+22+35 22+22+22+22+22+22+50 22+22+22+22+22+25+25 22+22+22+22+22+25+35 22+22+22+22+22+25+50 22+22+22+22+22+35+35 22+22+22+22+25+25+25 22+22+22+22+25+25+35 22+22+22+22+25+35+35 Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 2.19 / 2.5 2.05 / 2.34 2.41 / 2.76 2.19 / 2.5 2.06 / 2.35 1.93 / 2.21 2.0 / 2.29 1.89 / 2.16 2.26 / 2.58 2.06 / 2.35 1.94 / 2.22 1.89 / 2.16 2.12 / 2.42 1.94 / 2.22 2.8 / 3.2 2.2 / 2.51 2.2 / 2.51 2.12 / 2.43 1.92 / 2.2 1.81 / 2.07 1.7 / 1.94 2.2 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.18 / 2.5 2.04 / 2.33 1.86 / 2.12 1.75 / 2.0 1.91 / 2.19 1.75 / 2.0 1.8 / 2.06 2.14 / 2.44 2.0 / 2.28 1.82 / 2.08 1.72 / 1.97 1.88 / 2.15 1.72 / 1.97 1.77 / 2.02 1.67 / 1.91 2.1 / 2.39 1.96 / 2.24 1.79 / 2.04 1.69 / 1.93 1.84 / 2.1 1.69 / 1.93 1.73 / 1.99 2.33 / 2.66 2.19 / 2.5 2.0 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 1.94 / 2.22 2.0 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.2 1.81 / 2.07 1.66 / 1.9 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 B 2.19 / 2.5 2.05 / 2.34 2.41 / 2.76 2.19 / 2.5 2.06 / 2.35 1.93 / 2.21 2.0 / 2.29 1.89 / 2.16 2.26 / 2.58 2.06 / 2.35 1.94 / 2.22 1.89 / 2.16 2.97 / 3.39 2.72 / 3.11 2.8 / 3.2 2.2 / 2.51 2.2 / 2.51 2.12 / 2.43 1.92 / 2.2 1.81 / 2.07 1.7 / 1.94 2.2 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.18 / 2.5 2.04 / 2.33 1.86 / 2.12 1.75 / 2.0 1.91 / 2.19 1.75 / 2.0 1.8 / 2.06 2.14 / 2.44 2.0 / 2.28 1.82 / 2.08 1.72 / 1.97 1.88 / 2.15 1.72 / 1.97 1.77 / 2.02 1.67 / 1.91 2.38 / 2.72 2.23 / 2.55 2.03 / 2.33 1.92 / 2.2 2.1 / 2.4 1.92 / 2.2 1.98 / 2.26 2.33 / 2.66 2.19 / 2.5 2.0 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 1.94 / 2.2 2.0 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.2 1.81 / 2.07 1.66 / 1.9 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 C 2.19 / 2.5 2.05 / 2.34 2.41 / 2.76 2.19 / 2.5 2.06 / 2.35 1.93 / 2.21 2.0 / 2.29 1.89 / 2.16 3.16 / 3.61 2.88 / 3.29 2.72 / 3.11 2.65 / 3.03 2.97 / 3.39 2.72 / 3.11 2.8 / 3.2 2.2 / 2.51 2.2 / 2.51 2.12 / 2.43 1.92 / 2.2 1.81 / 2.07 1.7 / 1.94 2.2 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.18 / 2.5 2.04 / 2.33 1.86 / 2.12 1.75 / 2.0 1.91 / 2.19 1.75 / 2.0 1.8 / 2.06 2.43 / 2.78 2.27 / 2.6 2.07 / 2.37 1.96 / 2.23 2.13 / 2.44 1.96 / 2.23 2.0 / 2.3 2.66 / 3.04 2.38 / 2.72 2.23 / 2.55 2.03 / 2.33 1.92 / 2.2 2.1 / 2.4 1.92 / 2.2 1.98 / 2.26 2.33 / 2.66 2.19 / 2.5 2.0 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 1.94 / 2.22 2.0 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.2 1.81 / 2.07 1.66 / 1.9 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 D 2.19 / 2.5 2.05 / 2.34 3.38 / 3.86 3.06 / 3.5 2.88 / 3.29 2.71 / 3.09 4.0 / 4.56 3.78 / 4.32 3.16 / 3.61 2.88 / 3.29 2.72 / 3.11 3.78 / 4.32 2.97 / 3.39 2.72 / 3.11 2.8 / 3.2 2.2 / 2.51 2.2 / 2.51 2.12 / 2.43 1.92 / 2.2 1.81 / 2.07 1.7 / 1.94 2.2 / 2.52 2.08 / 2.38 1.89 / 2.16 1.78 / 2.03 1.67 / 1.91 1.95 / 2.23 1.78 / 2.03 1.68 / 1.92 2.48 / 2.83 2.32 / 2.65 2.1 / 2.41 1.99 / 2.27 2.17 / 2.47 1.99 / 2.27 2.86 / 3.27 2.43 / 2.78 2.27 / 2.6 2.07 / 2.37 1.96 / 2.23 2.13 / 2.44 1.96 / 2.23 2.82 / 3.22 2.66 / 3.04 2.38 / 2.72 2.23 / 2.55 2.03 / 2.33 1.92 / 2.2 2.1 / 2.4 1.92 / 2.2 2.77 / 3.16 2.33 / 2.66 2.19 / 2.5 2.0 / 2.28 1.89 / 2.16 2.06 / 2.35 1.89 / 2.16 2.72 / 3.11 2.0 / 2.28 1.96 / 2.24 1.84 / 2.11 1.69 / 1.93 1.92 / 2.2 1.81 / 2.07 1.66 / 1.9 1.71 / 1.96 1.89 / 2.16 1.78 / 2.03 1.68 / 1.92 MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 Capacity (kW) E F 5.24 / 6.0 5.8 / 6.64 3.38 / 3.86 4.37 / 5.0 4.94 / 5.65 5.49 / 6.28 4.0 / 4.56 4.54 / 5.19 3.16 / 3.61 4.12 / 4.71 4.67 / 5.33 3.78 / 4.32 2.97 / 3.39 3.89 / 4.44 2.8 / 3.2 2.2 / 2.51 2.2 / 2.51 2.2 / 2.51 2.5 / 2.85 2.12 / 2.43 3.38 / 3.85 1.92 / 2.2 4.38 / 5.0 1.81 / 2.07 4.94 / 5.65 1.7 / 1.94 5.49 / 6.28 2.5 / 2.86 2.5 / 2.86 2.36 / 2.7 3.31 / 3.78 2.15 / 2.45 4.29 / 4.91 2.02 / 2.31 4.86 / 5.55 1.9 / 2.17 5.4 / 6.17 3.1 / 3.54 3.1 / 3.54 2.83 / 3.24 4.05 / 4.62 2.68 / 3.06 4.59 / 5.25 2.48 / 2.83 2.48 / 2.83 2.32 / 2.65 3.24 / 3.71 2.1 / 2.41 4.22 / 4.82 1.99 / 2.27 4.77 / 5.45 3.04 / 3.48 3.04 / 3.48 2.78 / 3.18 3.98 / 4.55 2.86 / 3.27 2.86 / 3.27 2.43 / 2.78 2.43 / 2.78 2.27 / 2.6 3.18 / 3.64 2.07 / 2.37 4.14 / 4.73 1.96 / 2.23 4.68 / 5.36 2.99 / 3.41 2.99 / 3.41 2.74 / 3.13 3.9 / 4.47 2.82 / 3.22 2.82 / 3.22 2.66 / 3.04 2.66 / 3.04 2.38 /2.72 2.38 / 2.72 2.23 / 2.55 3.12 / 3.56 2.03 / 2.33 4.07 / 4.64 1.92 / 2.2 4.62 / 5.27 2.93 / 3.35 2.93 / 3.35 2.69 / 3.08 3.85 / 4.39 2.77 / 3.16 2.77 / 3.16 2.33 / 2.66 2.33 / 2.66 2.19 / 2.5 3.05 / 3.5 2.0 / 2.28 4.0 / 4.57 1.89 / 2.16 4.54 / 5.19 2.88 / 3.29 2.88 / 3.29 2.65 / 3.03 3.78 / 4.32 2.72 / 3.11 2.72 / 3.11 2.0 / 2.28 2.0 / 2.28 1.96 / 2.24 1.96 / 2.24 1.84 / 2.11 1.84 / 2.11 1.69 / 1.93 1.69 / 1.93 1.92 / 2.2 2.19 / 2.5 1.81 / 2.07 2.06 / 2.35 1.66 / 1.9 1.89 / 2.16 1.71 / 1.96 2.72 / 3.1 2.14 / 2.45 2.14 / 2.45 2.02 / 2.31 2.02 / 2.31 1.91 / 2.19 2.68 / 3.06 G 2.0 / 2.28 2.23 / 2.55 2.93 / 3.34 3.85 / 4.4 2.19 / 2.5 2.88 / 3.29 3.78 / 4.32 2.72 / 3.1 2.14 / 2.45 2.83 / 3.24 2.68 / 3.06 H Total 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 13.2 / 15.1 13.5 / 15.4 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 13.8 / 15.8 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 33 MXZ-8A140VA Combination Model 22+22+22+25+25+25+25 22+22+22+25+25+25+35 22+22+25+25+25+25+25 22+22+25+25+25+25+35 22+25+25+25+25+25+25 22+25+25+25+25+25+35 25+25+25+25+25+25+25 25+25+25+25+25+25+35 22+22+22+22+22+22+22+2 22+22+22+22+22+22+22+2 22+22+22+22+22+22+25+2 22+22+22+22+22+25+25+2 34 Operation mode Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating Cooling/Heating • Wall mounted systems: • Floor standing systems: • Ceiling concealed systems: • In-ceiling cassette systems: A 1.85 / 2.12 1.75 / 2.0 1.82 / 2.07 1.71 / 1.97 1.79 / 2.05 1.69 / 1.93 2.0 / 2.28 1.89 / 2.16 1.75 / 2.0 1.72 / 1.96 1.69 / 1.93 1.66 / 1.9 B 1.85 / 2.12 1.75 / 2.0 1.82 / 2.07 1.71 / 1.97 2.03 / 2.32 1.92 / 2.2 2.0 / 2.28 1.89 / 2.16 1.75 / 2.0 1.72 / 1.96 1.69 / 1.93 1.66 / 1.9 C 1.85 / 2.12 1.75 / 2.0 2.07 / 2.37 1.96 / 2.23 2.03 / 2.32 1.92 / 2.2 2.0 / 2.28 1.89 / 2.16 1.75 / 2.0 1.72 / 1.96 1.69 / 1.93 1.66 / 1.9 D 2.11 / 2.41 1.99 / 2.27 2.07 / 2.37 1.96 / 2.23 2.03 / 2.32 1.92 / 2.2 2.0 / 2.28 1.89 / 2.16 1.75 / 2.0 1.72 / 1.96 1.69 / 1.93 1.66 / 1.9 MSZ-FA25/35, MSZ-GA22/25/35/50/60/71 MFZ-KA25/35/50 SEZ-KC25, SEZ-KA35/50/60/71 SLZ-KA25/35/50 Capacity (kW) E F 2.11 / 2.41 2.11 / 2.41 1.99 / 2.27 1.99 / 2.27 2.07 / 2.37 2.07 / 2.37 1.96 / 2.23 1.96 / 2.23 2.03 / 2.32 2.03 / 2.32 1.92 / 2.2 1.92 / 2.2 2.0 / 2.28 2.0 / 2.28 1.89 / 2.16 1.89 / 2.16 1.75 / 2.0 1.75 / 2.0 1.72 / 1.96 1.72 / 1.96 1.69 / 1.93 1.69 / 1.93 1.66 / 1.9 1.89 / 2.16 G 2.11 / 2.41 2.78 / 3.18 2.07 / 2.37 2.74 / 3.13 2.03 / 2.32 2.69 / 3.07 2.0 / 2.28 2.65 / 3.03 1.75 / 2.0 1.72 / 1.96 1.92 / 2.2 1.89 / 2.16 H 1.75 / 2.0 1.96 / 2.23 1.92 / 2.2 1.89 / 2.16 Total 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 14.0 / 16.0 Optional Interfaces for M Series Inverters The M Series inverters of the latest generation are equipped with the new A-Control system, which enhances communications capabilities between the indoor and outdoor units. For example, indoor unit error messages can be displayed on the outdoor units and vice-versa. In addition to this the indoor units can also be fitted with optional interfaces. Currently two interfaces are available: 1. Interface for controlling M Series inverter indoor units via City Multi bus system (M-Net) This optional interface makes it possible to control the M Series inverters via City Multi M-Net data bus. You can connect the following City Multi remote controls, system timers and central remote controls to the MAC-399IF: G-50, PAC-SF44SRA, PAC-YT40ANRA, PAC-YT34STA, PAR-F27MEA If necessary, you can also control M Series inverters with one of the above City Multi controls directly, without integration in a City Multi bus system. Please note that those configurations require an installation of an additional power supply unit as PAC-SC-50KUA (optional). G-50 central controller, via Internet Explorer browser etc. Wall mounted unit M-NET Interface MAC-399IF-E 2. Interface for connecting M Series inverter indoor units to an external building management system or for integration of a wired or group remote control The following remote control commands are possible: 1. Remote ON/OFF 2. Output a status or error message (one message only) 3. Disable the ON/OFF function on the local remote control 4. Switch between cooling and heating mode 5. Change the setpoint temperature PAR-21MAA wired remote control or Floor standing unit MAC-397IF-E Building Management Interface Flush installation MAC821SC-E ON/OFF group remote control for up to 8 indoor units (separate 230V power supply required) 35 Series Accessories PARTICULATE MATTER FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1300FT 10 MSC-GA20/25/35VB MAC-1700FT 10 MS(H)-GA50/60/80VB MAC-1200FT 10 MCF/MCFH-GA35/50/60VB AIR CLEANING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS PAC-1000FT 1 SEZ-KA35/50/60VA LONG LIFE FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS PAC-KE32LAF 1 SEZ-KC25VA ANTI-ALLERGY-ENZYM FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-415FT-E 10 MSZ-GA22/25/35VA MFZ-KA25/35VA MAC-2300FT 10 MSZ-GA50/60/71VA MFZ-KA50 VA DEODORISING FILTER MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-1700DF Standard 10 MCF/MCFH-GA35/50/60VB MAC-305FT-E Ceramic 10 MSZ-FA25/35VA QUICK CLEAN KIT MODEL REFERENCE QUANTITY APPLICABLE MODELS MAC-093SS-E 1 MSZ-FA/GA PROTECTIVE COVERING BRANCH BOXES (for outdoor installation of PAC-AK30/50BC) MODEL REFERENCE QUANTITY APPLICABLE MODELS PAC-AK350CVR-E 1 PAC-AK30/50 Series Refrigerant Charge Outdoor units with R410A • Most outdoor units are precharged for 7m piping length (one way). • Refer to the tables on the right to calculate refrigerant volumes for longer piping. MU-GA20/25/35/50/60/80VB OUTDOOR UNITS MU-GA20VB MU-GA25VB MU-GA35VB MU-GA50VB MU-GA60VB MU-GA80VB Charge (one-way) in kg 10 m 15 m 20 m 0.660 0.760 0.860 0.660 0.760 0.860 0.760 0.860 0.960 1.590 1.610 1.710 2.060 2.160 2.260 2.465 2.880 3.115 7m 0.600 0.600 0.700 1.450 2.000 2.400 25 m – – 1.030 1.810 2.360 3.390 30 m – – – – – 3.565 MUCF-GA35/50/60VB OUTDOOR UNITS Charge (one-way) in kg 10 m 15 m 20 m 0.810 0.910 1.010 1.510 1.610 1.710 1.910 2.010 2.110 7m 0.750 1.450 1.850 MUCF-GA35VB MUCF-GA50VB MUCF-GA60VB 25 m 1.110 1.810 2.210 MUH-GA20/25/35/50/60/80VB OUTDOOR UNITS MUH-GA20VB MUH-GA25VB MUH-GA35VB MUH-GA50VB MUH-GA60VB MUH-GA80VB Charge (one-way) in kg 10 m 15 m 20 m 0.680 0.780 0.880 1.060 1.160 1.260 1.060 1.160 1.260 1.860 1.960 2.060 2.410 2.510 2.610 2.565 2.880 3.115 7m 0.620 1.000 1.000 1.800 2.350 2.400 25 m – – 1.360 2.160 2.710 3.390 30 m – – – – – 3.665 MUCFH-GA35/50/60VB OUTDOOR UNITS MUCFH-GA35VB MUCFH-GA50VB MUCFH-GA60VB 36 7m 1.000 1.850 2.200 Charge (one-way) in kg 10 m 15 m 20 m 1.060 1.160 1.260 1.910 2.010 2.110 2.260 2.360 2.460 25 m 1.360 2.210 2.560 Series Refrigerant Charge MUZ-GA25/35/50/60/71VA OUTDOOR UNITS 7m 0.850* 0.900* 1.800* 1.800* 2.000* MUZ-GA25VA MUZ-GA35VA MUZ-GA50VA MUZ-GA60VA MUZ-GA71VA Charge (one-way) in kg 10 m 15 m 20 m 1.000 1.150 1.300 1.050 1.200 1.350 1.860 1.960 2.060 1.860 1.960 2.060 2.165 2.265 2.365 25 m – – 2.160 2.160 2.465 30 m – – 2.260 2.260 2.565 Charge (one-way) in kg 10 m 15 m 20 m 0.950 1.100 1.250 1.050 1.200 1.350 1.860 1.960 2.060 1.860 1.960 2.060 2.165 2.440 2.715 25 m – – 2.160 2.160 2.990 30 m – – 2.260 2.260 3.265 SUZ-KA25/35/50/60/71VA OUTDOOR UNITS 7m 0.860* 0.960* 1.800* 1.800* 2.000* SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA SUZ-KA60VA SUZ-KA71VA MUX-2A28/2A59/2A70/3A60/3A63/4A73VB Charge (one-way) in kg 10 m 15 m 20 m 25 m 30 m – 1.000* 0.800* 0.900* 1.060 0.860 0.950 1.160 0.960 1.000 – – 1.050 – – 1.100 – – 1 X MSC-GA25VB 1 X MSC-GA35VB 0.950* 0.950* 1.010 1.010 1.110 1.110 – – – – – – 1 1 1 X MSC-GA25VB 2 X MSC-GA35VB 0.800* – 0.850 1.000* 0.960 1.050 – 1.100 – 1.150 – 1.200 MUX-3A63VB 1 1 1 X MSC-GA25VB 2 X MSC-GA35VB 0.850* – 0.910 0.850* 1.010 0.900 – 0.950 – 1.000 – 1.050 MUX-4A73VB 1 1 2 X MSC-GA25VB 2 X MSC-GA35VB – – 1.050* 1.050* 1.100 1.100 1.150 1.150 1.200 1.200 1.250 1.250 Number of compressors Indoor units 7m MUX-2A28VB MUX-2A59VB 1 1 1 2 X MSC-GA20VB 1 X MSC-GA25VB 1 X MSC-GA35VB MUX-2A70VB 1 1 MUX-3A60VB OUTDOOR UNITS MXZ-2A40/52VA, MXZ-3A54VA, MXZ-4A71/80VA OUTDOOR UNITS MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA 20 m 1.300* 1.300* – – – Charge (one-way) in kg 30 m 40 m 50 m 1.500 – – 1.500 – – – 2.700* 2.900 – 2.700* 2.900 – 3.500* 3.700 60 m – – – 3.100 3.900 70 m – – – – 4.100 MXZ-8A140VA OUTDOOR UNITS MXZ-8A140VA 40 m 8.5* Charge (one-way) in kg 41-50 m 51-70 m 9.5 10.2 71-90 m 11.0 91-115 m 12.0 * Factory precharged 37 Series Combining outdoor units and Mr. Slim indoor units Do you need room air conditioning in order to make it more comfortable or to create a more pleasant work atmosphere? Choosing the right configuration is easy with the wide range of units available from Mitsubishi Electric. Our M Series and Mr. Slim product lines are highly flexible air conditioning systems developed with three top priorities in mind: comfortable climate, economical power consumption and maximum flexibility to make planning and installation easier. The new A-Control system fitted in all M Series inverters and Mr. Slim units makes extensive combination options possible, both within and between the lines. For example, you can combine M Series outdoor units with Mr. Slim indoor units and enjoy all the benefits of both product families. The tables below show the possible combinations: SINGLE SPLIT IN-CEILING CASSETTE SYSTEMS INDOOR UNIT Series OUTDOOR UNIT cooling capacity (kW) heating capacity (kW) PLA-RP35AA SUZ-KA35VA 1.0 – 3.5 – 3.9 0.9 – 4.1 – 5.0 PLA-RP50AA SUZ-KA50VA 1.1 – 5.3 – 5.6 0.9 – 5.7 – 7.2 PLA-RP60AA SUZ-KA60VA 1.1 – 5.7 – 6.3 0.9 – 6.9 – 8.0 PCA-RP60GA SUZ-KA60VA 1.1 – 5.5 – 6.3 0.9 – 6.9 – 8.0 PCA-RP71GA SUZ-KA71VA 0.9 – 7.1 – 8.3 0.9 – 7.9 – 10.4 PEAD-RP50EA SUZ-KA50VA 1.1 – 5.0 – 5.6 0.9 – 5.9 – 7.2 PEAD-RP60EA SUZ-KA60VA 1.1 – 6.0 – 6.3 0.9 – 7.5 – 8.0 PLA-RP71AA SUZ-KA71VA 0.9 – 7.2 – 8.3 0.9 – 8.1 – 10.4 CEILING SUSPENDED SYSTEMS INDOOR UNIT Series OUTDOOR UNIT cooling capacity (kW) heating capacity (kW) PCA-RP50GA SUZ-KA50VA 1.1 – 4.9 – 5.6 0.9 – 6.0 – 7.2 CEILING CONCEALED SYSTEMS INDOOR UNIT Series OUTDOOR UNIT cooling capacity (kW) heating capacity (kW) PEAD-RP35EA SUZ-KA35VA 1.0 – 3.4 – 3.9 0.9 – 3.9 – 5.0 PEAD-RP71EA SUZ-KA71VA 0.9 – 7.1 – 8.3 0.9 – 8.2 – 10.4 COMPACT CEILING CONCEALED (just 275 mm height) INDOOR UNIT PEAD-RP60GA OUTDOOR UNIT Series SUZ-KA60VA cooling capacity (kW) 1.1 – 5.5 – 6.3 heating capacity (kW) 0.9 – 7.1 – 8.0 PEAD-RP71GA SUZ-KA71VA 0.9 – 7.1 – 8.3 0.9 – 8.2 – 10.4 Further combinations with SUZ outdoor units and Mr. SLIM indoor units on demand possible. MULTI SPLIT OUTDOOR UNIT Series MXZ-2A40VA MXZ-2A52VA MXZ-3A54VA MXZ-4A71VA MXZ-4A80VA MXZ-8A140VA 38 Max. connectable indoor units (number) 2 2 3 4 4 8 Type INDOOR UNITS PLA-RP AA PCA-RP GA PEAD-RP EA PEAD-RP GA In-ceiling cassette systems Ceiling suspended systems Ceiling concealed systems Ceiling concealed systems compact Connectable up to model size 25+35 35 50 60 71 71 Single and Multi Split Systems Economical and flexible cooling/heating performance In medium-sized rooms the air conditioners of the Mr. Slim series can be installed both as single-split and in multi-split configurations. A wide range of different units are available, including versions with additional electrical heating. This makes configuring the right system for your specific needs easier, no matter whether you have an office, a shop, a restaurant or a medical practice. If you want you can also connect the indoor units to inverter or non-inverter outdoor units, which come precharged with R410A refrigerant. The Power Inverter outdoor units are a new development from Mitsubishi Electric, combining maximum energy efficiency with very low noise levels. A comprehensive range of accessories rounds off the extensive Mr. Slim line. 39 Highlights of Mr. Slim series: ● Wide range of indoor and outdoor units for flexible combinations ● Cooling/heating capacities from 3.5/4.0 to 28.0/31.5 kW ● The RP indoor units can be connected in Cooling Only or Cooling/Heating mode to the PU(H) Non-Inverter, SUZ, PUHZ-P Inverter and PUHZRP Power Inverter outdoor units ● The SUZ and PUHZ-P/RP outdoor units feature state-ofthe-art inverter technology and eco-friendly R410A refrigerant for outstanding energy efficiency ● ● ● ● ● ● ● ● ● ● Rating conditions Mr. Slim series: ● Outdoor units PUHZ-P/RP Cooling Indoor: 19° to 35°C (DB), 15° to 22.5°C (WB) Outdoor: -15° to 46°C (DB) Heating Indoor: 17° to 28°C (DB) Outdoor: -11° to 24°C (DB), -20° to 18°C (WB) ● Outdoor units PU(H)-P Cooling Indoor: 19° to 35°C (DB), 15° to 22.5°C (WB) Outdoor: -15° to 46°C (DB) Heating Indoor: 17° to 28°C (DB) Outdoor: -11° to 24°C (DB), -12° to 18°C (WB) ● Outdoor units PUH-P200/250MYA* Cooling Indoor: 15° to 24°C (WB) Outdoor: -15° to 46°C (DB) Heating Indoor: 15° to 27°C (DB) Outdoor: -12° to 18°C (WB) ● Outdoor units SUZ-KA Cooling Indoor: 21° to 32°C (DB), 15° to 23°C (WB) Outdoor: -10° to 43°C (DB) Heating Indoor: 20° to 27°C (DB) Outdoor: -9° to 21°C (DB), -10° to 15°C (WB) 40 ● ● ● ● ● Special LOW NOISE mode with the PUHZ-P/RP outdoor units – just 43 dB(A) for the smallest model Simultaneous operation of 2, 3 or 4 indoor units Autochange over between cooling and heating mode (heat pump models) Indoor units with electrical heater as warm start system (heat pump in heating mode) Outdoor units come pre-charged with R410A refrigerant* Wired or infrared remote control Long-life, high-performance filters The new A-Control controller enables direct communication between indoor and outdoor units. Alarms and error messages can be checked directly with the remote control Drain pump included as standard equipment for better water drainage of all inceiling cassettes Winter kit for cooling operation down to -15°C. Wind shield required when installed facing in the predominant wind direction (see accessories)** Remote monitoring Maintenance Tool for easy monitoring and servicing (optional) Available either with central remote control or central controller and Lonworks® interface to building management / City Multi system Can be directly connected to the ventilation systems of the Lossnay series Connection kit for external heat exchangers * PUH-P200/250MYA with R407C refrigerant ** Down to -10°C with SUZ Mr. SLIM Indoor units with additional electrical heating Combinations with non-inverter outdoor units Mr. Slim indoor units are available as Cooling, Cooling/Heating and Warm Start systems. The RP indoor units can be combined with the SUZ (Cooling/Heating), PUHZ-P (Cooling/Heating), PUHZ-RP (Cooling/Heating) or PU(H)-P outdoor units (Cooling Only, Cooling/Heating), depending on your system requirements. A wide range of Warm Start systems with supplementary electrical heating are available, listed in the table below. Type Wall Mounted Systems Ceiling Suspended Systems In-Ceiling Cassette Systems Capacity (kW) Cooling Heating Model reference Indoor unit 4.5 5.4 6.5 7.9 9.5 5.8 7.1 9.5 11.6 13.3 PKH-P35GALH PKH-P50GALH PKH-P60FALH PKH-P71FALH PKH-P100FALH 5.4 7.7 PCH-P50GAH 6.7 7.5 9.7 12.4 14.3 9.4 11.3 13.4 17.9 20.1 PCH-P60GAH PCH-P71GAH PCH-P100GAH PCH-P125GAH PCH-P140GAH 4.4 5.3 6.3 7.8 9.7 12.8 14.3 6.4 7.4 9.5 11.4 12.7 17.9 20.1 PLH-P35AAH PLH-P50AAH PLH-P60AAH PLH-P71AAH PLH-P100AAH PLH-P125AAH PLH-P140AAH Outdoor unit 3 Phases, 380-415V only for simultaneous operation PUH-P71YHA PUH-P100YHA only for simultaneous operation PUH-P71YHA PUH-P100YHA PUH-P125YHA PUH-P140YHA only for simultaneous operation PUH-P71YHA PUH-P100YHA PUH-P125YHA PUH-P140YHA Grille for wired remote control PLP-6AAMD for infrared remote control PLP-6AALM Ceiling Concealed Systems 4.5 5.6 6.7 7.7 9.7 12.3 14.1 5.9 7.2 8.7 11.2 12.9 16.9 19.7 PEHD-P35EAH PEHD-P50EAH PEHD-P60EAH PEHD-P71EAH PEHD-P100EAH PEHD-P125EAH PEHD-P140EAH PUH-P71YHA PUH-P100YHA PUH-P125YHA PUH-P140YHA 7.7 9.7 12.4 14.0 11.4 13.6 17.6 20.1 PSH-P71GAH PSH-P100GAH PSH-P125GAH PSH-P140GAH PUH-P71YHA PUH-P100YHA PUH-P125YHA PUH-P140YHA Floor Standing Systems only for simultaneous operation Combinations for simultaneous operation are listed on page 58. 41 41 Mr. Slim Split Systems Cooling/Heating 4-Way In-Ceiling Cassettes Highlights • Compact design with a square • Adjustable air outlets for optimal format requires minimum ceiling space, installation recess is just 258 or 298 mm • Lightweight with noise-reduced housing – just 27 dB(A) for PLA-RP35AA • Fitted with drain pump as standard equipment for up to 850 mm height difference (from suspended ceiling) • Precisely-directed airflow prevents collection of dust on ceiling cladding • Four-level fan for highest climate comfort • Ready for external air duct connection airflow in rooms with ceiling heights up to 4.2 m • Ready for duct connections: circular 150 mm and rectangular 350 x 100 mm • Duo, Trio and Quadruple combinations possible • Includes infrared remote control with real-time clock and 24-hour timer or wired remote control with week timer and multi-language display (depends on grille type) Accessories • Adapter plinth for installation of the PLA-RP100/125/140AA in ceilings with a recess of just 258 mm, multifunctional outside air connection casement with filter holder and high-performance filter, see page 56 PLA-RP 4-WAY IN-CELLING CASSETTES, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Noise dB(A) Weight Weight incl. Grille Dimensions Dimensions (Grille) Electrical Supply (V, Phase, Hz) Running Current (kW) (kW) (m³/h) Low Medium 1 Medium 2 High Low High (kg) (kg) (mm) Width Depth Height* (mm) Width Depth Height* (A) Indoor Unit Grille for wired remote control Grille for infrared remote control Outdoor Unit Non-Inverter, Cooling only Outdoor Unit Non-Inverter, Cooling/Heating Outdoor Unit Standard-Inverter Outdoor Unit Power-Inverter PLA-RP35AA PLA-RP50AA PLA-RP60AA PLA-RP71AA PLA-RP100AA PLA-RP125AA PLA-RP140AA 4.5 5.6 6.7 8.0 10.0 12.3 14.2 5.0 6.4 7.3 9.2 10.5 15.6 17.0 660 840 840 900 1140 1440 1440 720 900 900 960 1260 1500 1500 780 960 960 1080 1380 1620 1620 840 1080 1080 1200 1620 1800 1800 27 28 28 28 33 37 37 31 33 33 34 41 45 45 24 24 24 24 32 32 32 29 29 29 29 37 37 37 840 840 840 840 840 840 840 840 840 840 840 840 840 840 258 258 258 258 298 298 298 950 950 950 950 950 950 950 950 950 950 950 950 950 950 30 30 30 30 30 30 30 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 0.79 0.79 0.79 0.79 PLA-RP35AA PLP-6AAMD PLP-6AALM – – SUZ-KA35VA PUHZRP35VHA PLA-RP50AA PLP-6AAMD PLP-6AALM – – SUZ-KA50VA PUHZRP50VHA PLA-RP60AA PLP-6AAMD PLP-6AALM – – SUZ-KA60VA PUHZRP60VHA PLA-RP71AA PLP-6AAMD PLP-6AALM PU-P71YHA PUH-P71YHA – PUHZRP71VHA * Visible height of grille The noise level is measured at 1.5 m below the indoor unit in anechoic chamber. 42 1.25 1.64 1.64 PLA-RP100AA PLA-RP125AA PLA-RP140AA PLP-6AAMD PLP-6AAMD PLP-6AAMD PLP-6AALM PLP-6AALM PLP-6AALM PU-P100YHA PU-P125YHA PU-P140YHA PUH-P100YHA PUH-P125YHA PUH-P140YHA PUHZ-P100VHA PUHZ-P125VHA PUHZ-P140VHA PUHZPUHZPUHZRP100YHA RP125YHA RP140YHA Mr. Slim Split Systems Cooling/Heating Ceiling Suspended Units Highlights • Simple installation with easy access to all connections • Long-life air filters as standard equipment • Swing louvers for even air distribution • Airflow and volume adjustable for ceilings with heights of up to 3.5 m • Duo, Trio and Quadruple combinations possible • Gratest convenience due to four fan stages • Wired remote control with week timer and multi-language display included as standard equipment Accessories • High-performance filter • Drain pump • Infrared remote control, see page 56 PCA-RP CEILING SUSPENDED UNITS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Noise dB(A) Weight Dimensions Electrical Supply (V, Phase, Hz) Running Current (kW) (kW) (m³/h) Low Medium 1 Medium 2 High Low High (kg) (mm) Width Depth Height (A) Indoor Unit Outdoor Unit Non-Inverter, Cooling only Outdoor Unit Non-Inverter, Cooling/Heating Outdoor Unit Standard-Inverter Outdoor Unit Power-Inverter PCA-RP50GA PCA-RP60GA PCA-RP71GA 5.35 6.6 7.5 6.2 7.3 9.2 600 840 840 660 900 900 720 960 960 780 1080 1080 37 37 37 42 43 43 27 34 34 1000 1310 1310 680 680 680 210 210 210 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 PCA-RP100GA 9.8 10.6 1200 1260 1380 1500 40 45 37 1310 680 270 220-240, 1, 50 PCA-RP125GA 12.3 14.8 1620 1800 1920 2040 41 46 43 1620 680 270 220-240, 1, 50 PCA-RP140GA 14.2 17.0 1620 1800 1920 2040 42 48 45 1620 680 270 220-240, 1, 50 0.41 0.53 0.53 0.69 1.01 1.01 PCA-RP50GA – – SUZ-KA50VA PUHZ-RP50VHA PCA-RP60GA – – SUZ-KA60VA PUHZ-RP60VHA PCA-RP71GA PU-P71YHA PUH-P71YHA – PUHZ-RP71VHA PCA-RP100GA PU-P100YHA PUH-P100YHA PUHZ-P100VHA PUHZ-RP100YHA PCA-RP125GA PU-P125YHA PUH-P125YHA PUHZ-P125VHA PUHZ-RP125YHA PCA-RP140GA PU-P140YHA PUH-P140YHA PUHZ-P140VHA PUHZ-RP140YHA The noise level is measured at 1 m in front of and 1 m below the indoor unit in anechoic chamber. 43 Mr. Slim Split Systems Cooling/Heating Stainless Steel Ceiling Suspended Units Highlights • Stainless steel version of our well–establishid ceiling suspended unit – ideal for applications in kitchens • Special design for fast cleaning of casing and all air transport components • Optional high-performance filter can trap airborne oil particles 1.5 times more efficiently than standard filters • Wired remote control with week timer and multilanguage display included as standard equipment • Circular fresh air inlet (ø 200 mm) on the rear panel for improved comfort • Duo, Trio and Quadruple combinations possible Accessories High-performance oil mist filter, see page 56 PCA-RP STAINLESS STEEL CEILING SUSPENDED UNITS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Noise dB(A) Weight Dimensions Electrical Supply (V, Phase, Hz) Running Current (kW) (kW) (m³/h) Low High Low High (kg) (mm) Width Depth Height (A) Indoor Unit Outdoor Unit Non-Inverter, Cooling only Outdoor Unit Non-Inverter, Cooling/Heating Outdoor Unit Standard-Inverter Outdoor Unit Power-Inverter PCA-RP71HA 7.5 9.2 1020 1140 34 38 41 1136 650 280 220-240, 1, 50 PCA-RP125HA 12.3 16.0 1800 2280 44 50 56 1520 650 280 220-240, 1, 50 0.53 1.01 PCA-RP71HA PU-P71YHA PUH-P71YHA – PUHZ-RP71VHA PCA-RP125HA PU-P125YHA PUH-P125YHA PUHZ-P125VHA PUHZ-RP125YHA The noise level is measured at 1 m in front of and 1 m below the indoor unit in anechoic chamber. 44 Mr. Slim Split Systems Cooling/Heating Wall Mounted Units Highlights • Slim, compact design requires minimum space and enable for practical wall mounting • Swing louvers for even air distribution • Easily-accessible connections for simple installation and quick maintenance • Equipped with long-life air filters which can be easily removed • Four-level fans in PKA-RP35 and RP50GAL for highest climate comfort • Infrared remote control PKA-RP-FAL with 24-hour timer included as standard equipment • Inverter technology for power saving and maximum comfort • Duo, Trio and Quadruple combinations possible PKA-RP-GAL Accessories • Drain pump and wired remote control, see page 56 PKA-RP WALL MOUNTED UNITS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Noise dB(A) Weight Dimensions Electrical Supply (V, Phase, Hz) Running Current (kW) (kW) (m³/h) Low Medium 1 Medium 2 High Low High (kg) (mm) Width Depth Height PKA-RP35GAL 4.5 5.0 540 600 660 720 36 43 16 990 235 340 220-240, 1, 50 PKA-RP50GAL 5.4 6.2 540 600 660 720 36 43 16 990 235 340 220-240, 1, 50 PKA-RP60FAL 6.5 7.4 900 1200 39 45 24 1400 235 340 220-240, 1, 50 PKA-RP71FAL 7.9 9.4 900 1200 39 45 24 1400 235 340 220-240, 1, 50 PKA-RP100FAL 9.8 10.8 1320 1680 41 46 28 1680 235 340 220-240, 1, 50 (A) 0.33 0.33 0.43 0.43 0.52 PKA-RP35GAL – – SUZ-KA35VA PUHZ-RP35VHA PKA-RP50GAL – – SUZ-KA50VA PUHZ-RP50VHA PKA-RP60FAL – – SUZ-KA60VA PUHZ-RP60VHA PKA-RP71FAL PU-P71YHA PUH-P71YHA – PUHZ-RP71VHA PKA-RP100FAL PU-P100YHA PUH-P100YHA PUHZ-P100VHA PUHZ-RP100YHA Indoor Unit Outdoor Unit Non-Inverter, Cooling only Outdoor Unit Non-Inverter, Cooling/Heating Outdoor Uni Standard-Inverter Outdoor Power-Inverter The noise level is measured at 1 m in front of and 1 m below the indoor unit in anechoic chamber. 45 Mr. Slim Split Systems Cooling/Heating Floor Standing Units Highlights • Simple installation, versatile positioning • Wired remote control with week timer and multi-language display integrated in the front panel • Vertical air outlet with swing mode • Standard long-life filter • Extra long airflow range (PSA-RP140: 16 m) provides ideal air conditioning even in large rooms, halls and marquees PSA-RP FLOOR STANDING UNITS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Noise dB(A) Weight Dimensions Electrical Supply (V, Phase, Hz) Running Current (kW) (kW) (m³/h) Low High Low High (kg) (mm) Width Depth Height (A) Indoor Unit Outdoor Unit Non-Inverter, Cooling only Outdoor Unit Non-Inverter, Cooling/Heating Outdoor Standard-Inverter Outdoor Power-Inverter PSA-RP71GA 7.6 9.0 900 1080 40 45 43 600 270 1900 220-240, 1, 50 PSA-RP100GA 10.0 11.5 1440 1860 44 49 51 600 350 1900 220-240, 1, 50 PSA-RP140GA 14.0 17.0 1620 2100 47 52 53 600 350 1900 220-240, 1, 50 0.66 1.06 1.23 1.59 PSA-RP71GA PU-P71YHA PUH-P71YHA – PUHZ-RP71VHA PSA-RP100GA PU-P100YHA PUH-P100YHA PUHZ-P100VHA PUHZ-RP100YHA PSA-RP125GA PU-P125YHA PUH-P125YHA PUHZ-P125VHA PUHZ-RP125YHA PSA-RP140GA PU-P140YHA PUH-P140YHA PUHZ-P140VHA PUHZ-RP140YHA The noise level is measured at 1 m in front of and 1 m below the indoor unit in anechoic chamber. 46 PSA-RP125GA 12.3 14.3 1560 1980 46 51 51 600 350 1900 220-240, 1, 50 Mr. Slim Split Systems Cooling/Heating Ceiling Concealed Ducted Systems Highlights • Just 295-325 mm high for opti- mum integration in suspended ceilings • Wired remote control with week timer and multi-language display included as standard equipment • Standard equipped with long-life filters, cleaning required just every 2500 hours in normal operation • Simple installation with easy access drain and refrigerant piping connections • Simultaneous multi-split operation supported • Inverter technology for power saving and maximum comfort Accessories • Drain pump and fan motor for 130 Pa external static pressure, see page 56 PEAD-RP CEILING CONCEALED DUCTED SYSTEMS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Static Pressure Noise dB(A) Weight Dimensions (kW) (kW) (m³/h) Low High (Pa) Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Indoor Units Outdoor Non-Inverter, Cooling only Outdoor Non-Inverter, Cooling/Heating Outdoor Standard-Inverter Outdoor Power-Inverter (A) PEAD-RP35EA PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA PEAD-RP125EA PEAD-RP140EA 4.5 5.6 6.6 7.9 9.6 12.2 14.0 4.9 6.3 7.2 9.1 10.3 14.0 16.6 660 810 1020 1200 1620 2010 2190 840 1020 1260 1500 2040 2520 2760 30 (70) 30 (70) 30 (70) 70(130*) 70(130*) 70(130*) 70(130*) 34 36 37 37 44 44 46 38 40 41 41 50 50 51 33 35 42 44 65 65 70 935 935 1175 1175 1415 1415 1715 700 700 700 740 740 740 740 295 295 295 325 325 325 325 220-240, 1, 220-240, 1, 220-240, 1, 220-240, 1, 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 50 50 50 50 0.55 0.63 0.7 1.7 2.6 2.7 2.8 PEAD-RP35EA PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA PEAD-RP100EA PEAD-RP125EA PEAD-RP140EA – – – PU-P71YHA PU-P100YHA PU-P125YHA PU-P140YHA – – – PUH-P71YHA PUH-P100YHA PUH-P125YHA PUH-P140YHA – SUZ-KA35VA SUZ-KA50VA SUZ-KA60VA PUHZ-P100VHA PUHZ-P125VHA PUHZ-P140VHA PUHZPUHZPUHZPUHZPUHZPUHZPUHZRP35VHA RP50VHA RP60VHA RP71VHA RP100YHA RP125YHA RP140YHA * Fan motor 130 Pa optional PEAD-RP35-60EA variable airflow, PEAD-RP71-140EA horizontal airflow The noise level is measured at 1 m in front of and 1 m below the indoor unit in anechoic chamber. 47 Mr. Slim Split Systems Cooling/Heating Compact Concealed Ducted Systems (variable airflow) • Simultaneous multi-split opera- Highlights • Very compact ducted units with an installation height of just 275 mm for maximum flexibility • Wired remote control with week timer and multi-language display included as standard equipment • Equipped with long-life filters as standard • Inverter technology for power saving and maximum comfort tion supported • Simple installation with easy access drain and refrigerant piping connections Accessories • Drain pump, see page 56 PEAD-RP COMPACT CONCEALED DUCTED SYSTEMS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Static Pressure Noise dB(A) Weight Dimensions (kW) (kW) (m³/h) Low High (Pa) Low High (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Indoor Unit Outdoor Non-Inverter, Cooling only Outdoor Non-Inverter, Cooling/Heating Outdoor Standard-Inverter Outdoor Power-Inverter (A) PEAD-RP60GA 6.6 7.2 990 1260 10/50/70 33 36 42 1171 740 275 220-240, 1, 50 PEAD-RP71GA 7.6 9.1 1200 1500 10/50/70 35 37 42 1171 740 275 220-240, 1, 50 PEAD-RP100GA 9.6 10.3 1590 1980 10/50/70 40 42 50 1411 740 275 220-240, 1, 50 0.8 0.94 1.25 PEAD-RP60GA – – SUZ-KA60VA PUHZ-RP60VHA PEAD-RP71GA PU-P71YHA PUH-P71YHA – PUHZ-RP71VHA PEAD-RP100GA PU-P100YHA PUH-P100YHA PUHZ-P100VHA PUHZ-RP100YHA The noise level is measured at 1 m in front of and 1 m below the indoor unit in anechoic chamber. 48 Mr. Slim Split Systems Cooling/Heating Concealed Ducted Systems with high static pressure Highlights • Static pressure up to 150 Pa • Duo, Trio and Quadruple com- binations possible • Connetable with non-inverter PUH-P200/250MYA (R407C) or power inverter PUHZ-RP200/250YHA (R410A) outdoor units • Wired remote control with week timer and multi-language display included as standard equipment • High airflow volume up to 4800 m³/h (PEH-RP250MYA) PEH-RP CONCEALED DUCTED SYSTEMS, COOLING/HEATING Indoor Unit Cooling Capacity Heating Capacity Airflow Static Pressure Noise Weight Dimensions (kW) (kW) (m³/h) (Pa) dB(A) (kg) (mm) Width Depth Height Electrical Supply (V, Phase, Hz) Running Current Indoor Unit Outdoor Non-Inverter, Cooling/Heating Outdoor Power-Inverter (A) PEH-RP200MYA 20.9 23.7 3600 50/150 49 70 1380 650 428 380-415, 3, 50 PEH-RP250MYA 26.0 30.5 4800 50/150 53 80 1580 650 428 380-415, 3, 50 1.1 1.6 PEH-RP200MYA PUH-P200MYA PUHZ-RP200YHA PEH-RP250MYA PUH-P250MYA PUHZ-RP250YHA The noise level is measured at a position of 1.5 m below the indoor unit in anechoic chamber. 49 PAC-AH10A-G connection kit for existing heat exchangers in recirculation mode ● ● The connection kit consists of a controller box (includes special circuit board with microprocessor controller) and two temperature sensors. It is connected to the control system of the Mr. Slim outdoor unit. D The optional PAR-21MAA standard wired remote control can be used for selecting the operating mode and setting the temperature setpoint. Control via external signals is possible. C E A B I H F G A PAC-AH10A-G connection kit B Ventilation system C Customer’s ventilation system controller D Mr. Slim outdoor unit E Customer’s heat exchanger F Suction pipe G Liquid pipe/inlet pipe H Inlet pipe temperature sensor I Return air/room air temperature sensor Detailed information will provided on demand. CONNECTION KIT PAC-AH10A-G COOLING CAPACITY min – max* AIRFLOW EXTERNAL min – max AIRTEMPERATURE MAX. PIPING LENGTH MAX. HEIGHT DIFFERENCE REFRIGERANT DIMENSIONS (mm) WEIGHT SET TEMPERATURE AT CONTROL PROTECTION CLASS ELECTRICAL SUPPLY (kW) (m3/h) (°C WB) (m) (m) Height Width Depth (kg) (°C) (V,Phase,Hz) 5.6 – 28.0 800-5000 15-24 50 40 R407C / R410A 382 326 117 7 14-30 IP24 220-240, 1, 50 * The required cooling capacity must be set via Dip switch at the connection kit. FUNCTIONS Operation Operation via wired remote control External ON/OFF Display opertion status Temperature Control Error messages 50 Start/Stop-function via external signal of RLT system Setpoint specification via wired remote control Temperature limited by external ON/OFF signal of customer’s thermostat via potential-free contact ● ● Overview outdoor units Type Non-Inverter PU-P PUH-P Cooling only Cooling or Heating Capacity code 35 50 60 71 100 125 140 200 250 Cooling (kW) 3.5 5.0 6.0 7.1 10.0 12.5 14.0 22.4 28.0 Heating (kW) 4.0 4.5 7.0 8.0 11.0 14.0 16.0 25.0 31.5 ● ● PU(H)-P71YHA ● ● PU(H)-P100YHA ● ● ● ● PU(H)-P125/140YHA ● ● PUH-P200/250MYA (R407C) Standard Inverter SUZ-KA PUHZ-P ● ● ● SUZ-KA35VA SUZ-KA50/60VA ● PUHZ-P100VHA PUHZ-P125/140VHA ● ● Power Inverter PUHZ-RP PUHZ-RP35/50VHA PUHZ-RP60/71VHA PUHZ-RP100/125/140YHA ● ● ● ● ● ● ● ● ● PUHZ-RP200/250YHA VHA: 230 V, 1 Phase, 50 Hz YHA: 400 V, 3 Phases, 50 Hz 51 Mr. Slim Non-Inverter Cooling/Heating PU(H)P-71YHA PU(H)P-100YHA PU(H)P-125/140YHA PUH-P200/250MYA (R407C) OUTDOOR UNIT, COOLING ONLY Model Reference Cooling Capacity Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Refrigerant Charge* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (kW) Cooling (m³/h) db(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (A) (A) Cooling PU-P71YHA 7.5 2.87 PU-P100YHA 9.6 3.41 PU-P125YHA 12.7 4.86 PU-P140YHA 14.2 5.4 3300 49 93 950 330 943 50 50 3.6 10 16 380-415, 3, 50 3900 50 94 950 330 943 50 50 4.4 10 16 380-415, 3, 50 6000 50 131 950 330 1350 50 50 5.0 10 16 380-415, 3, 50 6000 51 131 950 330 1350 50 50 5.0 10 16 380-415, 3, 50 5.3 16 5.6 16 7.6 25 9.0 25 PUH-P71YHA 7.5 8.2 2.87 2.9 3300 49 93 950 330 943 50 50 3.6 10 16 380-415, 3, 50 PUH-P100YHA 9.6 10.5 3.41 3.73 3900 50 94 950 330 943 50 50 4.4 10 16 380-415, 3, 50 PUH-P125YHA 12.7 13.6 4.86 4.8 6000 50 131 950 330 1350 50 50 5.0 10 16 380-415, 3, 50 PUH-P140YHA 14.2 16.0 5.4 5.69 6000 51 131 950 330 1350 50 50 5.0 10 16 380-415, 3, 50 PUH-P200MYA 20.9 23.7 7.92 7.82 11100 56 215 990 840 1715 50 40 6.0 12 22 380-415, 3, 50 PUH-P250MYA 26.0 30.5 9.96 9.56 11100 57 220 990 840 1715 50 40 6.5 12 28 380-415, 3, 50 5.3 5.6 16 5.6 5.9 16 7.6 8.2 25 9.0 9.6 25 13.0 12.8 25 16.0 15.4 25 * pre-charged for 30 m pipe length (one way) OUTDOOR UNIT, COOLING/HEATING Model Reference Cooling Capacity Heating Capacity Power Consumption, incl. Indoor Unit Airflow Noise Weight Dimensions Max. Pipe Length Max. Height Difference Refrigerant Charge* Pipe Size (kW) (kW) Cooling Heating (m³/h) db(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. Electrical Supply (V, Phase, Hz) Running Current (A) Recommend Safety Fuse (A) Cooling Heating * pre-charged for 30 m pipe length (one way), PUH-P200/250MYA pre-charged with R407C 6.0/6.5 kg 52 Mr. Slim Standard Inverter Cooling/Heating SUZ-KA35VA SUZ-KA50/60VA PUHZ-P100VHA PUHZ-P125/140VHA OUTDOOR UNIT, COOLING/HEATING Model References Cooling Capacity Heating Capacity Power Consumption, incl. Indoor Unit Luftvolumenstrom Noise Low/High Weight Dimensions Max. Pipe Length Max. Height Difference Refrigerant Charge* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (kW) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (A) (A) SUZ-KA35VA 3.5 (1.0-3.9) 4.0 (0.9-5.0) 0.69 0.83 2004 47/48 37 800 285 550 20 12 1.05 6 10 220-240, 1, 50 SUZ-KA50VA 5.0 (1.1-5.6) 5.9 (1.1-7.2) 1.06 1.09 2940 51/55 53 840 330 850 30 15 1.6 6 12 220-240, 1, 50 SUZ-KA60VA 5.5 (1.1-6.3) 6.9 (0.9-8.0) 1.63 1.54 2940 51/55 53 840 330 850 30 15 1.8 6 16 220-240, 1, 50 4.9 10 8.0 20 9.0 20 PUHZ-P100VHA 9.4 11.2 3.12 3.28 3600 50/54 75 950 330 943 50 30 2.7 10 16 220-240, 1, 50 PUHZ-P125VHA 12.3 14.0 4.09 4.11 6000 51/55 123 950 330 1350 50 30 4.5 10 16 220-240, 1, 50 PUHZ-P140VHA 13.6 16.0 5.21 4.98 6000 52/56 123 950 330 1350 50 30 4.5 10 16 220-240, 1, 50 12.26 32 17.37 32 22.48 40 * pre-charged for 7 m pipe length (one-way) OUTDOOR UNIT, COOLING/HEATING Model Reference Cooling Capacity Heating Capacity Power Consumption, incl. Indoor Unit Airflow Noise Low/High Weight Dimensions Max. Pipe Length Max. Height Difference Refrigerant Charge* Pipe Size Electrical Supply (V, Phase, Hz) Running Current Recommend Safety Fuse (kW) (kW) Cooling Heating (m³/h) db(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (A) (A) * pre-charged for 30 m pipe length (one-way). PUHZ-P100 pre-charged for 20 m pipe length 53 Mr. Slim Power Inverter Cooling/Heating PUHZ-RP35/50VHA PUHZ-RP60/71VHA PUHZ-RP100/125/140YHA OUTDOOR UNIT, COOLING/HEATING Model Reference Cooling Capacity Heating Capacity Power Consumption, incl. Indoor Unit Airflow Noise Low/High Weight Dimensions Max. Pipe Length Max. Height Difference Refrigerant Charge* Pipe Size (kW) (kW) Cooling Heating (m³/h) db(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. Electrical Supply (V, Phase, Hz) Running Current (A) Recommend Safety Fuse (A) Cooling Heating PUHZ-RP35VHA 3.6 (1.6-4.5) 4.1 (1.6-5.2) 1.07 1.12 2100 44/46 45 800 300 600 50 30 2.2 6 12 220-240, 1, 50 PUHZ-RP50VHA 5.0 (2.3-5.6) 6.0 (2.5-7.3) 1.55 1.62 2100 44/46 45 800 300 600 50 30 2.5 6 12 220-240, 1, 50 PUHZ-RP60VHA 6.0 (2.7-6.7) 7.0 (2.8-8.2) 1.65 1.85 3300 47/48 75 950 330 943 50 30 3.5 10 16 220-240, 1, 50 PUHZ-RP71VHA 7.1 (3.3-8.1) 8.0 (3.5-10.2) 1.97 2.34 3300 47/48 75 950 330 943 50 30 3.5 10 16 220-240, 1, 50 4.0 4.23 16 6.2 6.47 16 6.6 7.50 25 8.0 9.74 25 OUTDOOR UNIT, COOLING/HEATING Model Reference Cooling Capacity Heating Capacity Power Consumption, incl. Indoor Unit Airflow Noise Low/High Weight Dimensions Max. Pipe Length Max. Height Difference Refrigerant Charge* Pipe Size (kW) (kW) Cooling Heating (m³/h) db(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. Electrical Supply (V, Phase, Hz) Running Current (A) Recommend Safety Fuse (A) Cooling Heating * pre-charged for 30 m pipe length (one-way). 54 PUHZ-RP100YHA 10.0 (4.9-11.4) 11.2 (4.5-14.0) 3.02 3.02 6000 49/51 135 950 330 1350 75 30 5.0 10 16 380-415, 3, 50 PUHZ-RP125YHA 12.5 (5.5-14.0) 14.0 (5.0-16.0) 3.87 3.88 6000 50/52 130 950 330 1350 75 30 5.0 10 16 380-415, 3, 50 PUHZ-RP140YHA 14.0 (5.5-15.3) 16.0 (5.0-18.0) 4.65 4.69 6000 50/52 130 950 330 1350 75 30 5.0 10 16 380-415, 3, 50 3.8 4.33 16 4.9 5.41 16 6.5 6.37 16 Mr. Slim Power Inverter Cooling/Heating Simultaneous operation up to 4 indoor units OUTDOOR UNIT, COOLING/HEATING Model Reference Cooling Capacity Heating Capacity Power Consumption, incl. Indoor Unit Airflow Noise Low/High Weight Dimensions Max. Pipe Length Max. Height Difference Max. Distance Length Refrigerant Charge* Pipe Size (kW) (kW) Cooling Heating (m³/h) db(A) (kg) (mm) Width Depth Height (m) (m) (m) (kg) Ø (mm) fl. s. Electrical Supply (V, Phase, Hz) Running Current (A) Recommend Safety Fuse (A) Cooling Heating PUHZ-RP200YHA 19.0 (10.0-22.4) 22.4 (10.0-25.0) 6.76 6.98 9000 55/56 198 900 750 1798 120 40 80 10.5 10 22 380-415, 3, 50 PUHZ-RP250YHA 22.0 (12.5-28.0) 27.0 (15.7-31.5) 7.83 8.41 9000 58/58 198 900 750 1798 120 40 80 10.5 12 28 380-415, 3, 50 10.0 10.4 32 11.5 12.4 32 * pre-charged for 30 m pipe length (one-way) 55 Accessories Accessories for indoor units Model Reference Description PLA/PLH PAC-SG04AS-E PAC-SG03TM-E PAC-SG01KF-E In-Ceiling Cassette Systems Space panel for PLA-RPAA/PLH-PAAH enables installation in just 258 mm depth. Multi-function casement for PLH-P, PLA-RP High efficiency filter for PLH-P, PLA-RP (PAC-SG03TM-E is needed) Air outlet shutter for PLA-RPAA/PLH-PAAH PAC-SG06SP-E PCA/PCH PAC-SH20DM-E PAC-SH21DM-E PAC-SH22DM-E PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E PAR-SL99B-E Ceiling Suspended Systems Drain pump for PCA-RP50/60GA with 600 mm delivery height Drain pump for PCH-P50/60/71GAH, PCA-RP71GA with 600 mm delivery height Drain pump for PCH-P100/125/140GAH, PCA-RP100/125/140GA with 600 mm delivery height High efficiency filter for PCH-P50GAH, PCA-RP50GA. The high efficiency filter replaces the standard filter. High efficiency filter for PCH-P60/71/100GAH, PCA-RP60/71/100GA. The high efficiency filter replaces the standard filter. High efficiency filter for PCH-P125/140GAH, PCA-RP125/140GA. The high efficiency filter replaces the standard filter. Infrared remote control for PCH-P, PCA-RP. The set comprises the infrared remote control, wall holder and receiver. PCA PAC-SF28OF-E PAC-SG38KF-E PAC-SF81KC-E PAC-SF82KC-E Stainless Steel Ceiling Suspended Systems Round duct connection for fresh air intake, ø 200 mm Special high efficiency oil filter, 12 pieces Wide panel for PCA-RP71HA between unit and ceiling to prevent dust and soiling Wide panel for PCA-RP125HA between unit and ceiling to prevent dust and soiling PKA/PKH PAC-SE90DM-E Wall Mounted Systems Drain pump for PKH-P60/71/100, PKA-RP60/71/100FAL. For an installation to the left of the unit, delivery height 800 mm. Dimensions WxHxD: 300 x 300 x 184 mm Wired remote control for PKH-P, PKA-RPGAL/FAL. The wired remote control is needed for the operation of the weekly timer PAC-YT32PTA or of the adapter PAC-SF40RM-E for remote monitoring PAR-21MAAT-E PEAD/PEHD PAC-KE03DM-F PAC-SK005MT-F PAC-SK004MT-F PAC-SK003MT-F 56 Ceiling Concealed Systems Drain pump for PEHD-P, PEAD-RP-EA with 500 mm delivery height Fan motor 130 Pa pressure for PEHD-P71EAH, PEAD-RP71EA Fan motor 130 Pa pressure for PEHD-P100EAH, PEAD-RP100EA Fan motor 130 Pa pressure for PEHD-P125/140EAH, PEAD-RP125/140EA Accessories Accessories for outdoor units Model Reference Description PU/PUH PAC-SF37DS-E PAC-SF16DP-E PAC-SF17DP-E PAC-SF08SG-E PAC-SF09AG Non-Inverter Drain socket for PU(H)-P35 - P140 Drain pan for PU(H)-P35 - P100 Drain pan for PU(H)-P125/140 Air outlet guide for PU(H)-P35 - P140 (for P100/125/140 two air outlet guides are required) Airflow panel for PU(H)-P35 - P140 (for P100/125/140 2x PAC-SF09AG) cooling up to -15°C. PUHZ-RP PAC-SG61DS-E PAC-SG63DP-E PAC-SG64DP-E PAC-SG92DS-E PAC-SG56AG-E PAC-SG63AG-E Power Inverter Drain socket for PUHZ-RP35 - RP140, MXZ-8A140VA Drain pan for PUHZ-RP35/50 Drain pan for PUHZ-RP60 - RP140, MXZ-8A140VA Drain pan for PUHZ-RP200/250 Airflow panel for PUHZ-RP35/50 cooling up to -15°C Airflow panel for PUHZ-RP60 - RP140 cooling up to -15°C. For PUHZ-RP100/125/140 two airflow panels are required. Airflow panel for PUHZ-RP200/250 cooling up to -15°C (front and back) Airflow panel for PUHZ-RP200/250 cooling up to -15°C (right and left) Air outlet guide for PUHZ-RP35/50 Air outlet guide for PUHZ-RP60 - RP140. For PUHZ-RP100/125/140 two air outlet guides are required. PAC-SG86AG-E PAC-SG87AG-E PAC-SG58SG-E PAC-SG59SG-E Control Accessories Model Reference PAC-SE41TS-E PAC-SF40RM-E PAC-SE55RA-E PAC-SA88HA-E PAC-YT32PTA Maintenance Tool CMS-MNF-B PAC-SF60MA-E PAC-SF70MA-E LMAP02-E PAC-SC50KU-A PAC-SK52ST Description External Temperature Sensor Adapter for remote monitoring, operation only with wired remote control models Remote ON/OFF adapter Cable for connection to Mr. Slim indoor units with A-control (RP35 to RP140). 12 DC signal for operation and error messages. LCD weekly set back program timer, operation only with wired remote control models Maintenance Tool consists of hard- and software for easy service and remote monitoring. The A/M converter is needed (PAC-SF60MA-E, PAC-SF70MA-E), standard PC and cable RS-232. Further information are available in the City Multi part. A/M Net-Converter for outdoor units R407C/R410A (not possible for PUHZ-RPYHA) A/M Net-Converter for outdoor units PUHZ-RPYHA LonWorks®-Interface. For the operation are required PAC-SF70MA-E and PAC-SC50KU-A. Power supply Service-Display for outdoor units P35 - P140 and RP35 - RP140 Further information are available in the planning handbook Mr. Slim 57 Accessories for Multi Split Systems* / Distributors Mr. Slim series supports simultaneous operation of two (Duo), three (Trio) or four (Quadruple) indoor units with one outdoor unit. Indoor units of different types can be combined. The Mr. Slim series is particularly well suited for large rooms that constitute a single climate zone, such as shops or open-plan offices. COMBINATIONS • FLOOR STANDING SYSTEMS PLA-RP/PLH-P35/50/60/71/100/125 PSA-RP/PSH-P71/100/125 • CEILING SUSPENDED SYSTEMS • CEILING CONCEALED DUCTED SYSTEMS PCA-RP/PCH-P50/60/71/100/125 PEAD-RP/PEHD-P35/50/60/71/100/125 • WALL MOUNTED SYSTEMS PKA-RP/PKH-P35/50/60/71 OUTDOOR UNITS Twin 50:50 Twin 50:50 Triple 33:33:33 Triple 25:25:50 Triple 20:40:40 Quadruple 25:25:25:25 PU(H)/PUHZ-P/RP71 35+35 PU(H)/PUHZ-P/RP100 50+50 PU(H)/PUHZ-P/RP125 60+60 PU(H)/PUHZ-P/RP140 71+71 50+50+50 PU(H)/PUHZ-P/RP200 100+100 60+60+60 50+50+50+50 PU(H)/PUHZ-P/RP250 125+125 71+71+71 60+60+60+60 PUH-P200MYA 100+100 60+60+60 50+50+100 35+71+71 50+50+50+50 PUH-P250MYA 125+125 71+71+71 60+60+125 50+100+100 60+60+60+60 DISTRIBUTOR MODEL MSDD-50SR-E MSDD-50WR-E MSDT-111R-E SDT-112SA-E SDT-122SA-E MSDF-1111R-E INDOOR UNITS • IN-CEILING CASSETTES DISTRIBUTORS OF REFIGERANT MODEL MSDD-50SR-E MSDD-50WR-E MSDT-111R-E SDT-112SA-E SDT-122SA-E MSDF-1111R-E DESCRIPTION Twin 50:50 Twin 50:50 Triple 33:33:33 Triple 25:25:50 Triple 20:40:40 Quadruple 25:25:25:25 *Note: For multi split operation the indoor units must be installed in same room or climate zone because of just one active room temperature sensor in the master unit. Further information are avaible in the Mr. Slim databook. 58 Refrigerant Specifications R410A Non-Inverter R410A Charge concering for single operation, parallel operation requires different volumes (see planning guide) ● OUTDOOR UNITS 10 m 3.4 4.2 4.8 4.8 7.0 7.5 PU(H)-P71YHA PU(H)-P100YHA PU(H)-P125YHA PU(H)-P140YHA PUH-P200MYA PUH-P250MYA CHARGING (one way) in kg 20 m 30 m 3.5 3.6* 4.3 4.4* 4.9 5.0* 4.9 5.0* 7.5 8.0 8.0 8.5 40 m 4.2 5.0 5.6 5.6 8.5 9.0 50 m 4.2 5.6 6.2 6.2 9.0 9.5 * factory charged Non-Inverter R407C P200 and P250 outdoor units are delivered charged with 6 kg/6.5 kg of refrigerant. Refer to the tables on the right to calculate total refrigerant charges based on piping lengths. ● Correction factor for Non-Inverter R410A CAPACITY CODE PIPING LENGTH (one way) in m CORRECTION FACTOR CAPACITY OF COOLING / HEATING 5 10 15 20 25 30 35 40 45 50 P71 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978 P100 1.00/1.00 0.989/0.998 0.980/0.995 0.970/0.993 0.960/0.990 0.950/0.988 0.940/0.985 0.930/0.983 0.920/0.980 0.910/0.978 P125 1.00/1.00 0.981/0.998 0.968/0.995 0.952/0.993 0.940/0.990 0.925/0.988 0.913/0.985 0.900/0.983 0.886/0.980 0.874/0.978 P140 1.00/1.00 0.975/0.998 0.955/0.995 0.935/0.993 0.918/0.990 0.900/0.988 0.884/0.985 0.869/0.983 0.855/0.980 0.840/0.978 P200 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.965/0.995 0.960/0.995 0.940/0.995 0.935/0.995 0.930/0.995 P250 1.00/1.00 0.980/1.00 0.980/1.00 0.979/1.00 0.975/1.00 0.960/0.995 Power Inverter R410A ● The PUHZ-RP outdoor units are delivered charged for 30 m of piping (one-way). For longer pipe lengths refer to the table on the right. OUTDOOR UNITS 10 m 2.1 2.1 3.1 3.1 4.6 4.6 4.6 – – PUHZ-RP35VHA PUHZ-RP50VHA PUHZ-RP60VHA PUHZ-RP71VHA PUHZ-RP100V(Y)HA PUHZ-RP125V(Y)HA PUHZ-RP140V(Y)HA PUHZ-RP200YHA PUHZ-RP250YHA 20 m 2.3 2.3 3.3 3.3 4.8 4.8 4.8 – – 0.958/0.995 0.955/0.995 0.950/0.995 CHARGING (one way) in kg 30 m 40 m 50 m 60 m 2.5 2.7 2.9 – 2.5 2.7 2.9 – 3.5 4.1 4.7 – 3.5 4.1 4.7 – 5.0 5.6 6.2 6.8 5.0 5.6 6.2 6.8 5.0 5.6 6.2 6.8 10.5 11.4 12.3 13.2 10.5 11.7 12.9 14.1 0.950/0.995 70 m – – – – – – – 14.1 15.3 75 m – – – – 7.4 7.4 7.4 * * * For piping lengths over 70 m please view our databook Mr. Slim Correction factor for Power Inverter R410A CAPACITY CODE CORRECTION FACTOR CAPACITY OF COOLING / HEATING 5 10 20 30 40 50 60 70 75 RP35 1.00/1.00 0.992/0.997 0.976/0.991 0.962/0.985 0.949/0.979 0.936/0.973 –/– –/– –/– RP50 1.00/1.00 0.985/0.997 0.957/0.991 0.931/0.985 0.908/0.979 0.886/0.973 –/– –/– –/– RP60 1.00/1.00 0.992/0.997 0.976/0.991 0.962/0.985 0.949/0.979 0.936/0.973 –/– –/– –/– RP71 1.00/1.00 0.988/0.997 0.966/0.991 0.946/0.985 0.929/0.979 0.913/0.973 –/– –/– RP100 1.00/1.00 0.957/0.991 0.957/0.991 0.931/0.985 0.908/0.979 0.886/0.973 0.865/0.967 0.846/0.961 0.829/0.955 RP125 1.00/1.00 0.981/0.997 0.946/0.991 0.914/0.985 0.885/0.979 0.858/0.973 0.834/0.967 0.812/0.961 0.792/0.955 RP140 1.00/1.00 0.976/0.997 0.932/0.991 0.893/0.985 0.858/0.979 0.828/0.973 0.813/0.970 0.776/0.961 0.753/0.955 RP200 1.00/1.00 0.984/0.999 0.958/0.990 0.930/0.985 0.908/0.980 0.888/0.975 0.867/0.968 0.848/0.960 0.839/0.958 RP250 1.00/1.00 0.984/0.999 0.958/0.990 0.930/0.985 0.908/0.980 0.888/0.975 0.867/0.968 0.848/0.960 0.839/0.958 PIPING LENGTH (one way) in m Standard Inverter R410A The PUHZ-P100VHA outdoor unit is delivered charged with 2.7 kg for 20 m of piping (oneway). The PUHZ-P125/140VHA outdoor units come charged with 4.5 kg for 30 m. For longer pipe lengths refer to the table on the right. ● PUHZ-P100VHA PUHZ-P125VHA PUHZ-P140VHA –/– ADDITIONAL CHARGING (one way) in kg 21 - 30 m 31 - 40 m 41 - 50 m 0.6 1.2 1.8 – 0.6 1.2 – 0.6 1.2 59 Combination with M-Series The new A-Control in all inverter indoor units enables a connection to the powerful and energy efficient outdoor units PUHZ-RP. The following combinations are possible: Outdoor type Indoor type Series PUHZ-RP35VHA Systems Model reference Wall mounted Floor standing In-ceiling cassette Ceiling concealed MSZ-GA35VA MFZ-KA35VA SLZ-KA35VAL SEZ-KA35VA Wall mounted Floor standing In-ceiling cassette Ceiling concealed MSZ-GA50VA MFZ-KA50VA SLZ-KA50VAL SEZ-KA50VA Wall mounted Ceiling concealed MSZ-GA60VA SEZ-KA60VA Wall mounted Ceiling concealed MSZ-GA71VA SEZ-KA71VA PUHZ-RP50VHA PUHZ-RP60VHA PUHZ-RP71VHA 60 VRF Systems Flexible and economical The City Multi VRF Systems (variable refrigerant flow) are geared to a modern architecture of big and complex buildings which require customized solutions for air condition. A wide range of various indoor units and the capacity spectrum of the outdoor units allow highest flexibility for planning and dimensioning. Long pipe lengths and space-saving outdoor units simplify the installation significantly. The economical advantage of the City Multi R2 series is outstanding due to the unique two-pipes-system with heat recovering. Surplus heat from cooling operations, especially in adjacent rooms, is distributed to office rooms where heat is needed. The watercooled WR2-System is adaptable to high-rise buildings. The high energy efficiency is reflected in best COP values based on the ecologically sensitive refrigerant R410A, full-invertertechnology and improvements of all components and assemblies. The Mitsubishi Electric VRF series can be connected easily to external ventilation systems or facility management systems. 61 City Multi VRF System Highlights: ● Wide range of outdoor units available with capacities from 11.2 – 140.0 kW for cooling and from 12.5 – 156.5 kW for heating. ● Up to 42 indoor units can be connected to a single refrigerant circuit (City Multi Super Y-System). ● The selection of 73 indoor and 47 outdoor units allows configuration of customised solutions. ● Three new Mini-VRF outdoor units (type PUMY) with refrigerant R410A for max. 6 or 8 indoor units. ● Mitsubishi Electric has developed close control systems (PFD series) that meet the most demanding requirements of computer centres and IT equipment rooms. ● All outdoor units have a coated Blue Fin heat exchanger with very effective protection against aggressive air. ● The special design of the heat exchanger in the outdoor units and the inverter controlled condenser-fan guarantee extremely low noise levels for all outdoor units (22.4 kW just 49 dB(A) measured 1 m in front of the unit during night operation). ● Very low starting currents thanks to full inverter driven technology ● State-of-the-art DC compressor technology ● The temperature range in heating mode is 15.5° to -20°C. So monovalent City Multi VRF systems are applicable for very cold regions. ● For applications requiring very low indoor temperatures the indoor units PEFY-P and PFFY-P have a special function to cool down rooms up to 14°C. ● All the components of the City Multi system are designed for maximum efficiency and achieve outstanding COP (Coefficient Of Performance) values with R410A refrigerant. Competitor with special T-Branches Best COP values for the watercooled outdoor units enable effective cost saving. 5.43 5.20 4.71 4.56 Mitsubishi Electric Competitor Mitsubishi Electric with standard T-Sections 15.- Euro mit T-Stücken ● Standard T-Sections can be used as branches. Due to the use of customary branches substantial material costs can be reduced. PQHY-P250YGM-A COP cooling mode COP heating mode *measured at JIS-Standard B8615-1 62 ● World-wide unique 2-pipe-system for simultaneous cooling and heating operation. R2 with air-cooled and WR2 with water-cooled heat exchangers. Mitsubishi Electric has succeeded in eliminating the third pipe required in conventional systems, significantly reducing installation overheads and costs. ● Up to 50% power savings with the heat recovery system. The heat energy recovered in cooling operation is used for simultaneous heating operation. ● Connection to local or central controllers of facility management systems possible with floating contacts, 12 V DC outputs, LON Works, BACNET or Fidelio. ● The outdoor units up to 45 kW have entirely internal piping, so that additional piping by customers is not needed. The outdoor units up to 140 kW require a maximum of eight connections. This is unmatched by any other units on the market and reduces installation expenses significantly. City Multi Y Series City Multi R2 Series The City Multi Y series uses 2-pipetechnology for cooling and heating operation. Users can switch modes manually and adjust individually for the most comfortable room climate. The system is very flexible as you can connect up to 42 different indoor units to a single refrigerant circuit, and the capacities of all the connected systems can range from 50% to 130%. For outdoor units with 22.0 up to 90.0 kW 160% are possible on demand. The City Multi R2 series is specially designed for power-conserving, environment-friendly installations in modern buildings. Sealed buildings with minimal natural air exchange and office equipment like PCs, printers, copiers etc. that give off a great deal of heat require modern air conditioning systems capable of simultaneous cooling and heating. The `fuzzy logic´ used in this series allows precise adjustment of up to 32 indoor units (City Multi Big R2 Series) for customer requirements. The outdoor unit is fitted with the latest inverter technology, enabling the compressor to be run at down to 16% of its rated capacity. In the WR2 series recovered heat is output to a water circuit, allowing it be stored or used in other locations in other WR2 systems. The heart of every R2 system is the BC Controller – a refrigerant distributor that links with the outdoor unit to form a single refrigerant and control system, thus enabling efficient heat recovery. Remote Control/ Central Control Wall-mounted and hand-held infrared remote control units are available for the City Multi Y and R2 series for operation of single indoor units. Furthermore group, system and central remote controllers are available to control up to 50 indoor units. For larger systems a PC-based control system can be used to handle up to 2.000 indoor units. LON Works interface and BACNET are available for connecting the air conditioners to facility management systems. Combination with external ventilation systems Special LEV-KITs (PAC-AH) enables an easy connection of the City Multi outdoor units to external ventilation systems. This passes on all the benefits of the City Multi outdoor units to the external systems, ensuring a perfectly fresh climate at all times. The capacities of all the connected systems can range from 50% to 150%. Guaranteed Operating Range: Measurement conditions for the MITSUBISHI ELECTRIC air conditioners: ● Cooling: Indoor 15° – 24°C (WB) / Outdoor -15° – 43°C (DB) (Outdoor cooling water temperature for WR2/WY: 10° – 45°C) ● Heating (Y Series): Indoor 15° – 27°C (DB) / Outdoor -20° – 15.5°C (WB) ● Heating (R2 Series): Indoor 15° – 27°C (DB) / Outdoor -20° – 15.5°C (WB) (Outdoor cooling water temperature for WR2: 10° – 45°C) Cooling: Indoor 27°C (DB) / 19°C (WB) Outdoor 35°C (DB) / 24°C (WB) (Outdoor cooling water temperature for WR2: 30°C) Heating: Indoor 20°C (DB) Outdoor 7° C (DB) / 6° C (WB) (Outdoor cooling water temperature for WR2/WY: 20°C) Refrigerant line length 7.5 m (one way), ⌬H = 0 m. Sound pressure level measured in free field, outdoor unit measurement point at height of 1 m and 1 m away from the unit. For indoor units point depends on unit model, see specifications. 63 High Convenience Cooling or Heating The City Multi Y-Series stands for maximum possible flexibility. A wide line-up of indoor units in combination with a flexible piping system can conform to any layout. Up to 42 various indoor models can be connected to Y-Standard, BIG Y and SUPER Y outdoor units, as well as to the water-cooled version WY. All indoor units connected to only one refrigerant circuit with 11.2 to 140 kW cooling capacity. This enables easy air conditioning of areas requiring individual control. Customary T-Branches are applicable 64 Unique 2-Pipe-System Simultaneous Cooling and Heating The City Multi R2- and WR2-Series allow simultaneous cooling and heating as 2-pipe-system, unique worldwide. Via the BC-Controller (Master + max. 2x Slave) up to 32 indoor units can be connected with one outdoor unit, using only two pipes* and energy-saving heat recovery operation. Economy and efficiency are guaranteed. Smooth auto-switching (heating/cooling) based on individual set temperature realises easier operation and more comfortable environment. The WR2-Series with water-cooled outdoor units provides the same well-known advantages of the R2-Series and is specially used for high-rise buildings. * when connecting more than 17 indoor units two BC-Controller are needed, only between Master and Slave are three pipes necessary. 65 Direct expansion format for excess refrigerant pipes outdoor unit PUMY-Series Total length ……………………………………………………………… 120 m Greatest length …………………………………………………………… 80 m Greatest length after first branch ……………………………………… 30 m Top-bottom differentials between Indoor and outdoor unit (outdoor higher) ……………………………… 30 m Indoor and outdoor unit (outdoor lower) ……………………………… 20 m Indoor units ……………………………………………………………… 12 m greatest length 80 m top-bottom differential 30 m top-bottom differential between indoor units 12 m indoor unit Y-Series outdoor unit Total length ……………………………………………………………… 300 m Greatest length……………………………………………………………150 m (Equivalent greatest length) ……………………………………………(175 m) Greatest length after first branch ……………………………………… 40 m Top-bottom differentials between Indoor and outdoor unit (outdoor higher) ……………………………… 50 m Indoor and outdoor unit (outdoor lower) ……………………………… 40 m Indoor units ……………………………………………………………… 15 m greatest length 150 m top-bottom differential 50 m top-bottom differential between indoor units 15 m indoor unit R2-Series Total length ………………………………………………………max. 400 m* Greatest length……………………………………………………………150 m (Equivalent greatest length) ……………………………………………(175 m) Length between outdoor unit and BC-Controller ……………………110 m Length between BC-Controller and indoor unit ……………………… 40 m Top-bottom differentials between Indoor and outdoor unit (outdoor higher) ………………………………50 m Indoor and outdoor unit (outdoor lower) ………………………………40 m Indoor units and BC-Controller…………………………………………15 m** Indoor units ………………………………………………………………15 m** outdoor unit top-bottom differential 50 m max. length between outdoor unit and BC-Controller 110 m max. length between BC-Controller and indoor unit 40 m BC-Controller * based on distance outdoor unit and BC-Controller maximum 70 m. ** max. 10 m for indoor units type P200 and P250. indoor unit top-bottom differential between indoor units and indoor units/ BC-Controller max. 15 m Big R2-Series Total length ………………………………………………………max. 400 m* Greatest length……………………………………………………………150 m (Equivalent greatest length) ……………………………………………(175 m) Length between outdoor unit and Master-Controller…………………110 m Length between Master-Controller and indoor unit ……………………40 m Top-bottom differentials between Indoor and outdoor unit (outdoor higher) ………………………………50 m Indoor and outdoor unit (outdoor lower) ………………………………40 m Indoor units and Master-, Slave-Controller……………………………15 m** Indoor units ………………………………………………………………15 m** Master- and Slave-Controller …………………………………………15 m** * based on distance outdoor unit and BC-Controller maximum 70 m. ** max. 10 m for indoor units type P200 and P250. 66 outdoor unit top-bottom differential 50 m BC-Controller indoor unit max. length between BC-Controller and indoor unit 40 m top-bottom differential between indoor units and indoor units/ BC-Controller max. 15 m The BC-Controller: Main item of R2-Systems To outdoor unit Installation of BC-Controller The compact BC-Controller connects Reducer several indoor units to one outdoor attached unit and distributes efficiently refrigerant in accordance to heating mode (gas refrigerant) and cooling mode Indoor (liquid refrigerant). Unit P20-P50 Jointpipe kit (CMY-R160-J) (optional) Indoor Indoor Unit P50-P140 Indoor Unit P200, P250 Branchpipe Indoor Indoor max. 3 indoor units per connection with max. total capacity 140 BC-Controller Operations BC-Controller Outdoor unit Indoor unit Compressor 4-way valve Cooling Low pressure gas operation primarily for cooling Cooling heat exchanger Cooling Fan High pressure gas Heating LEV High pressure liquid Outdoor unit BC-Controller Suction pipe Indoor unit 4-way valve Heating operation with total heat recovery Heating Low pressure Cooling Cooling Dischargeline Low pressure 2-phase Suction pipe Discharge-lines High pressure gas Low pressure gas 2-phase low pressure High pressure liquid 2-phase high pressure 67 CITY MULTI VRF Outdoor Units Overview Capacity Type Y-Series / Big Y-Series ● ● ● Cooling only Cooling or Heating Cooling and Heating Capacity code 100 140 200 250 300 350 400 450 500 550 600 650 Cooling (kW) 11.2 14.0 16.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 63.0 67.4 73.0 Heating (kW) PUMY 12.5 16.0 18.0 25.0 31.5 37.5 45.0 50.0 56.0 63.0 67.0 75.0 81.5 125 ● ● ● PUY ● ● ● ● PUHY ● ● ● ● ● ● ● ● ● ● Capacity Type Super Y-Series 900 950 1000 1050 1100 1150 1200 1250 Capacity code 700 750 800 850 Cooling (kW) 78.4 84.0 90.0 96.0 101.0 108.0 113.0 118.0 124.0 130.0 136.0 140.0 Heating (kW) 88.0 94.5 100.0 108.0 113.0 119.5 127.0 132.0 140.0 145.0 150.0 156.5 PUHY + PUHN ● ● ● PUHY ● ● ● ● ● ● ● ● ● Capacity Capacity code 125 200 250 300 350 400 450 500 550 600 650 Cooling (kW) 14.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 63.0 67.4 73.0 Type Heating (kW) 16.0 25.0 31.5 37.5 45.0 50.0 56.0 63.0 67.0 75.0 81.5 WY-Series PQHY + PQY ● ● R2-Series / Big R2-Series ● ● PURY ● ● ● ● ● ● ● ● ● ● WR2-Series PQRY + PQY ● ● 68 ● ● City Multi VRF Outdoor units - Technical data PUMY-P100/125/140YHM PUMY OUTDOOR UNITS, COOLING OR HEATING IN 400V-PERFORMANCE Model Reference Cooling Capacity Heating Capacity EER COP Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Max. Distance Length Refrigerant Charge*** Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) (kW) Cooling Heating (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (m) (kg) Ø (mm) Liquid Gas (kW) Cooling Heating Running Current (A) Max. Capacity Indoor Unit (kW) Connectable Indoor Units (Number/Type) PUMY-P100YHM 11.2 12.5 3.50 3.96 6000 49 140 950 330 + 30 1350 120 30 80 8.5 10 16 380-415V, 50Hz, 3 PUMY-P125YHM 14.0 16.0 3.29 3.75 6000 50 140 950 330 + 30 1350 120 30 80 8.5 10 16 380-415V, 50Hz, 3 PUMY-P140YHM 16.0 18.0 3.04 3.43 6000 51 140 950 330 + 30 1350 120 30 80 8.5 10 16 380-415V, 50Hz, 3 3.2 3.16 4.9 14.5 (130%) 1 - 6 / 20-125 4.25 4.27 6.5 18.2 (130%) 1 - 8 / 20-140 5.1 5.25 7.8 20.2 (130%) 1 - 8 / 20-140 * The noise levels are measured at a position 1 m in front of and 1.5 m above the unit in anechoic chamber. ** one-way *** R410A factory charged to 50 m pipe length (one-way) 69 City Multi VRF Outdoor units - Technical data STANDARD Y OUTDOOR UNITS, COOLING ONLY Model Reference Cooling Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size PUY-P200 to P350: Cooling only (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. Electrical Supply (V, Freq., Phase) Max. Input Power (kW) Starting Current (A) Running Current (A) Max. Capacity Indoor Unit*** (%) Connectable Indoor Units (Number/Type) PUYPUYPUYPUYP350YGM-A P200YGM-A P250YGM-A P300YGM-A 40.0 22.4 28.0 33.5 12000 12000 12000 12000 56 57 59 60 233 218 233 233 990 990 990 990 840 840 840 840 1840 1840 1840 1840 300 300 300 300 50 50 50 50 9.5 7.0 9.5 9.5 10 10 10 12 28 18 22 22 380-415V, 380-415V, 380-415V, 380-415V, 50Hz, 3 50Hz, 3 50Hz, 3 50Hz, 3 11.39 6.14 7.72 9.57 8 10 8 8 19.2 10.3 13.0 16.1 50-130 50-130 50-130 50-130 1-13 / 20-250 1-16 / 20-250 1-19 / 20-250 1-20 / 20-250 STANDARD Y OUTDOOR UNITS, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power PUHY-P200 to P350: Cooling or Heating (kW) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Starting Current (A) Running Current (A) Max. Capacity Indoor Unit*** (%) Connectable Indoor Units (Number/Type) PUHYPUHYPUHYPUHYP350YGM-A P200YGM-A P250YGM-A P300YGM-A 40.0 22.4 28.0 33.5 45.0 25.0 31.5 37.5 12000 12000 12000 12000 56 57 59 60 233 218 233 233 990 990 990 990 840 840 840 840 1840 1840 1840 1840 300 300 300 300 50 50 50 50 9.5 7.0 9.5 9.5 10 10 10 12 28 18 22 22 380-415V, 380-415V, 380-415V, 380-415V, 50Hz, 3 50Hz, 3 50Hz, 3 50Hz, 3 6.14 7.72 9.57 11.39 5.98 7.62 9.10 11.02 8 10 8 8 19.2 10.3 13.0 16.1 50-130 50-130 50-130 50-130 1-13 / 20-250 1-16 / 20-250 1-19 / 20-250 1-20 / 20-250 * The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way *** 50-160 % on demand possible 70 City Multi VRF Outdoor units - Technical data BIG Y OUTDOOR UNITS, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power PUHY-P400YGM-A 45.0 50.0 14400 61 275 1290 840 1840 300 50 13.0 12 28 380-415V, 50Hz, 3 (kW) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Starting Current (A) Running Current (A) (%) Max. Capacity Indoor Unit*** Connectable Indoor Units (Number/Type) 13.42 12.43 8 22.6 50-130 1-22 / 20-250 PUHY-P400YGM-A PUHY-P450 to P650YGM-A BIG Y OUTDOOR UNITS, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Running Current (A) Max. Capacity Indoor Unit (%) Connectable indoor units (Number/Type) PUHY-P450YGM-A 50.0 56.0 24000 60 455 1990 840 1840 300 50 22.0 16 28 380-415V, 50Hz, 3 PUHY-P500YGM-A 56.0 63.0 24000 60 455 1990 840 1840 300 50 22.0 16 28 380-415V, 50Hz, 3 PUHY-P550YGM-A 63.0 67.0 24000 61 455 1990 840 1840 300 50 22.0 16 28 380-415V, 50Hz, 3 PUHY-P600YGM-A 67.4 75.0 24000 61 455 1990 840 1840 300 50 22.0 16 28 380-415V, 50Hz, 3 PUHY-P650YGM-A 73.0 81.5 24000 62 455 1990 840 1840 300 50 22.0 16 28 380-415V, 50Hz, 3 13.61 13.86 21.8 50-130 1-24 / 20-250 15.59 15.89 25.0 50-130 1-24 / 20-250 17.08 16.37 27.3 50-130 1-24 / 20-250 17.59 17.73 28.2 50-130 1-32 / 20-250 19.65 19.82 31.5 50-130 1-32 / 20-250 * The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way *** 50-160 % on demand possible 71 City Multi VRF Outdoor units - Technical data SUPER Y OUTDOOR UNITS, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions PUHY-P700-800YGM-A require PUHN-P01 for operation! PUHY-P700YGM-A PUHY-P750YGM-A PUHY-P800YGM-A 78.4 84.0 90.0 88.0 94.5 100.0 14400 14400 14400 62 63 64 430 430 430 1690 1690 1690 840 840 840 1840 1840 1840 300 300 300 50 50 50 27.0 27.0 27.0 18 18 18 35 35 35 380-415V, 50Hz, 3 380-415V, 50Hz, 3 380-415V, 50Hz, 3 (kW) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) Cooling Heating Starting Current (A) Running Current (A) Max. Capacity Indoor Unit (%) Connectable Indoor Units (Number/Type) 21.70 21.83 15 34.8 50-130*** 1-34 / 20-250 24.90 25.37 15 39.9 50-130*** 1-34 / 20-250 26.75 26.90 15 42.9 50-130*** 1-34 / 20-250 HEAT EXCHANGER UNIT Model Reference Airflow Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Heat exhanger unit PUHN-P01 PUHN-P01YGM-A 14400 155 990 840 1840 12 28 380-415V, 50Hz, 3 (m³/h) (kg) (mm) Width Depth Height Ø (mm) fl. s. (kW) Cooling Heating 0.7 0.7 * The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way *** 50-160 % on demand possible The outdoor units of Super Y Series have to be connected to PUHN-P01. UNIT COMBINATION SUPER Y Model Reference Necessary combination PUHY-P700YSGM-A PUHY-P700YGM-A (compressor unit) PUHY-P750YSGM-A PUHY-P750YGM-A (compressor unit) PUHY-P800YSGM-A PUHY-P800YGM-A (compressor unit) 72 + PUHN-P01YGM-A Dimensions Width (heat exchanger unit) Depth Height + PUHN-P01YGM-A Width (heat exchanger unit) Depth Height + PUHN-P01YGM-A Width (heat exchanger unit) Depth Height Cooling capacity Heating capacity Max. connectable indoor units/types 2680 mm 78.4 kW 840 mm 1840 mm 2680 mm 84.0 kW 840 mm 1840 mm 2680 mm 90.0 kW 840 mm 1840 mm 88.0 kW 1-34 / 20-250 94.5 kW 1-34 / 20-250 100.0 kW 1-34 / 20-250 City Multi VRF Outdoor units - Technical data PUHY-P850 to P1250YSGM-A SUPER Y OUTDOOR UNITS, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) (kW) (m²/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Running Current (A) Max. Capacity Indoor Unit (%) Connectable Indoor Units (Number/Type) PUHY-P850YSGM-A 96.0 108.0 48000 63 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P900YSGM-A 101.0 113.0 48000 63 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P950YSGM-A 108.0 119.5 48000 63 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P1000YSGM-A 113.0 127.0 48000 63 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P1050YSGM-A 118.0 132.0 48000 63,5 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 25.28 27.47 40.5 50-130 1-42 / 20-250 26.71 29.10 42.8 50-130 1-42 / 20-250 29.23 30.42 46.8 50-130 1-42 / 20-250 31.11 32.68 49.8 50-130 1-42 / 20-250 33.48 34.24 53.6 50-130 1-42 / 20-250 SUPER Y OUTDOOR UNITS, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) (kW) (m²/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Running Current (A) Max. Capacity Indoor Unit (%) Connectable Indoor Units (Number/Type) PUHY-P1100YSGM-A 124.0 140.0 48000 64 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P1150YSGM-A 130.0 145.0 48000 64 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P1200YSGM-A 136.0 150.0 48000 64 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 PUHY-P1250YSGM-A 140.0 156.5 48000 65 918 3980 840 1840 300 50 44.0 18 42 380-415V, 50Hz, 3 36.39 36.93 58.3 50-130 1-42 / 20-250 39.96 38.46 64.0 50-130 1-42 / 20-250 44.40 39.73 71.2 50-130 1-42 / 20-250 47.56 42.63 76.2 50-130 1-42 / 20-250 * The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way The Super Y outdoor units are a combination of PUHY-P-YMM-A and PUHY-P400/650YSM-A. UNIT COMBINATION SUPER Y Model Reference PUHY-P850YSGM-A PUHY-P900YSGM-A PUHY-P950YSGM-A PUHY-P1000YSGM-A PUHY-P1050YSGM-A PUHY-P1100YSGM-A PUHY-P1150YSGM-A PUHY-P1200YSGM-A PUHY-P1250YSGM-A Necessary combination Dimensions (Main unit + Sub unit) Depth Height Width Width Width Width Width Width Width Width Width PUHY-P450YMM-A PUHY-P500YMM-A PUHY-P550YMM-A PUHY-P600YMM-A PUHY-P650YMM-A PUHY-P450YMM-A PUHY-P500YMM-A PUHY-P550YMM-A PUHY-P600YMM-A + + + + + + + + + PUHY-P400YSM-A PUHY-P400YSM-A PUHY-P400YSM-A PUHY-P400YSM-A PUHY-P400YSM-A PUHY-P650YSM-A PUHY-P650YSM-A PUHY-P650YSM-A PUHY-P650YSM-A 840 mm 1840 mm 3980 mm 3980 mm 3980 mm 3980 mm 3980 mm 3980 mm 3980 mm 3980 mm 3980 mm Cooling capacity Heating capacity Max. connectable indoor units / types 96.0 kW 101.0 kW 108.0 kW 113.0 kW 118.0 kW 124.0 kW 130.0 kW 136.0 kW 140.0 kW 108.0 kW 113.0 kW 119.5 kW 127.0 kW 132.0 kW 140.0 kW 145.0 kW 150.0 kW 156.5 kW 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 1-42 / 20-250 73 City Multi VRF WY-Series (water-cooled) Outdoor units - Technical data PQHY-P200/250YGM-A and PQHY-P400/500YSGM-A (sub unit PQY-P01 is required) The WY outdoor units must be installed indoors. WY-SERIES, COOLING OR HEATING Model Reference Cooling Capacity Heating Capacity EER COP Cooling Water Flow Rate Decrease of Pressure (Cool. Water) Noise* Weight Dimensions (mm) Total Pipe Length** Max. Height Difference Max. Distance Length Refrigerant Charge Pipe Size Electrical Supply (V,Freq., Phase) Max. Input Power (kW) (kW) Cooling Heating (m³/h) (kPa) dB(A) (kg) Width Depth Height (m) (m) (m) (kg) Ø (mm) Liquid Gas (kW) Cooling Heating Starting Current (A) Running Current (A) Max. Capacity Indoor Unit (%) Connectable Indoor Units (Number/Type) PQHY-P200YGM-A 22.4 25.0 4.7 5.3 4.6 16.5 46 272 990 550 1800 300 50 150 7.0 10 18 380-415V, 50Hz,3 PQHY-P250YGM-A 28.0 31.5 4.7 5.4 5.8 19.5 47 275 990 550 1800 300 50 150 9.5 10 22 380-415V, 50Hz,3 PQHY-P400YSGM-A 45.0 50.0 3.96 4.54 9.12 16.5 50 208+244 990 550 1800+1800 300 50 150 7+9.5 12 28 380-415V, 50Hz,3 PQHY-P500YSGM-A 56.0 63.0 3.72 4.63 11.52 19.5 53 208+248 990 550 1800+1800 300 50 150 7+9.5 16 28 380-415V, 50Hz,3 4.79 4.69 8.0 7.6 50-130 13 / 20-250 5.95 5.80 8.0 9.5 50-130 16 / 20-250 11.35 11.0 8.0 18.2 50-130 22 / 20-250 15.06 13.6 8.0 24.2 50-130 24 / 20-250 * The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way The Big WY outdoor units are a combination of PQHYPYGM-A (heat exchanger) and PQY-P01YGM-A (compressor) UNIT COMBINATION BIG WY Model Reference Necessary combination (Main unit + Sub unit) PQHY-P400YSGM-A PQHY-P500YSGM-A 74 PQHY-P400YGM-A PQHY-P500YGM-A + PQY-P01YGM-A + PQY-P01YGM-A City Multi VRF Outdoor units - Technical data R2 OUTDOOR UNITS, COOLING AND HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) (kW) (m²/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Starting Current (A) Running Current (A) Max. Capacity Indoor Unit (%) Connectable Indoor Units (Number/Type) PURYPURYPURYPURYP200YGM-A P250YGM-A P300YGM-A P350YGM-A 22.4 28.0 33.5 40.0 25.0 31.5 37.5 45.0 12000 12000 12000 12000 56 57 59 60 236 251 251 251 990 990 990 990 840 840 840 840 1840 1840 1840 1840 400 400 400 400 50 50 50 50 10.5 13.0 13.0 13.0 16 18 18 18 18 22 22 28 380-415V, 380-415V, 380-415V, 380-415V, 50Hz, 3 50Hz, 3 50Hz, 3 50Hz, 3 6.14 7.72 9.57 11.39 5.98 7.62 9.10 11.02 10 8 8 8 9.8 12.3 15.3 18.2 1-15 / 20-250 1-16 / 20-250 1-16 / 20-250 1-20 / 20-250 50-150 50-150 50-150 50-150 R2-Series: PURY-P200-350YGM-A BIG R2 OUTDOOR UNITS, COOLING AND HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power PURY-P400YGM-A 45.0 50.0 14400 61 291 1290 840 1840 400 50 13.0 22 28 380-415V, 50Hz, 3 (kW) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Starting Current (A) Running Current (A) Max. Capacity Indoor Unit (%) Connectable indoor units (Number/Type) 13.42 12.43 8 21.5 50-150 1-24 / 20-250 Big R2: PURY-P400YGM-A BIG R2 OUTDOOR UNITS, COOLING AND HEATING Model Reference Cooling Capacity Heating Capacity Airflow Noise* Weight Dimensions Max. Pipe Length** Max. Height Difference Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) (kW) (m³/h) dB(A) (kg) (mm) Width Depth Height (m) (m) (kg) Ø (mm) fl. s. (kW) Cooling Heating Running Current (A) Max. Capacity Indoor Unit (%) Connectable indoor units (Number/Type) PURYPURYPURYPURYPURYP450YGM-A P500YGM-A P550YGM-A P600YGM-A P650YGM-A 50.0 56.0 63.0 67.4 73.0 56.0 63.0 67.0 75.0 81.5 24000 24000 24000 24000 24000 60 60 61 61 62 481 481 481 481 481 1990 1990 1990 1990 1990 840 840 840 840 840 1840 1840 1840 1840 1840 400 400 400 400 400 50 50 50 50 50 16.5 16.5 16.5 16.5 16.5 22 22 28 28 28 28 28 28 28 28 380-415V, 380-415V, 380-415V, 380-415V, 380-415V, 50Hz, 3 50Hz, 3 50Hz, 3 50Hz, 3 50Hz, 3 13.61 15.59 17.08 17.59 19.65 13.86 15.89 16.37 17.73 19.82 21.8 25.0 27.3 28.2 31.5 50-150 50-150 50-150 50-150 50-150 1-24 / 20- 1-24 / 20- 1-24 / 20- 1-32 / 20- 1-32 / 20250 250 250 250 250 * The noise levels are measured at a position 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way Big R2-Series: PURY-P450-650YGM-A 75 BC-Controller Outdoor units - Technical data BC- Controller: Distributes the refrigerant for simultaneous cooling and heating operation with heat recovery R2 BC-CONTROLLER Model Reference Pipe Size external Ø (mm) BC-Controller at outdoor unit Weight Dimensions (mm) CMB-P104V-G 18 22 CMB-P105V-G 18 22 CMB-P106V-G 18 22 24 648 432 284 220-240V, 50Hz, 1 0.076 0.34 max. 4/ 20-250* 27 648 432 284 220-240V, 50Hz, 1 0.093 0.41 max. 5/ 20-250* 29 648 432 284 220-240V, 50Hz, 1 0.110 0.48 max. 6/ 20-250* fl. s. CMBP108V-GA 22 28 CMBP1010V-GA 22 28 CMBP1013V-GA 22 28 CMBP1016V-GA 22 28 fl. s. s. 10 16 18 10 16 18 10 16 18 10 16 18 44 1110 520 289 220-240V, 50Hz, 1 0.144 0.63 max. 8/ 20-250* 49 1110 520 289 220-240V, 50Hz, 1 0.177 0.77 max. 10/ 20-250* 57 1110 520 289 220-240V, 50Hz, 1 0.228 1.00 max. 13/ 20-250* 64 1110 520 289 220-240V, 50Hz, 1 0.279 1.22 max. 16/ 20-250* fl. s. (kg) Width Depth Height Electrical Supply (V, Freq., Phase) Max. Input Power (kW) Running Current (A) Connectable indoor units (Number/Type) CMB-P108V-G CMB-P1010V-G CMB-P1013V-G CMB-P1016V-G 18 18 18 18 22 22 22 22 34 648 432 284 220-240V, 50Hz, 1 0.144 0.63 max.8/ 20-250* 39 648 432 284 220-240V, 50Hz, 1 0.177 0.77 max.10/ 20-250* 47 1098 432 284 220-240V, 50Hz, 1 0.228 1.00 max.13/ 20-250* 54 1098 432 284 220-240V, 50Hz, 1 0.279 1.22 max.16/ 20-250* BIG R2 MASTER-CONTROLLER Model Reference Pipe Size external Ø (mm) BC-Controller at outdoor unit Pipe Size external Ø (mm) Master-Controller at SlaveController Weight Dimensions (mm) (kg) Width Depth Height Electrical Supply (V, Freq., Phase) Max. Input Power (kW) Running Current (A) Connectable indoor units (Number/Type) Master-Controller for Big R2 BIG R2 SLAVE-CONTROLLER Model Reference Pipe Size s. external Ø (mm) fl. Master-Controller at Slaves. Controller Pipe Size fl. external Ø (mm) s. Indoor unit at SlaveController (kg) Weight Dimensions (mm) Width Depth Height Electrical Supply (V, Freq., Phase) Running Current (A) Connectable indoor units (Number/Type) CMB-P104V-GB 10 18 22 CMB-P108V-GB 10 18 22 10 16 10 16 22 648 432 284 220-240V, 50Hz, 1 32 648 432 284 220-240V, 50Hz, 1 0.3 max. 4/ 20-250* 0.59 max. 8/ 20-250* * for max. 3 indoor units with a capacity up to 140 will be needed only one branch 76 The Slave BC-Controller can only use in combination with the Master-Controller. Maximum two Slave-Controller can be connected with the Master-Controller. City Multi VRF WR2-Series (water-cooled) Outdoor units - Technical data PQRY-P200/250YGM-A and PQRY-P400/500YSGM-A (sub unit PQY-P01 is required) The WR2 outdoor units must be installed indoors. WR2-SERIES, COOLING AND HEATING Model Reference Cooling Capacity Heating Capacity EER COP Cooling Water Flow Rate Decrease of Pressure (cool. water) Noise* Weight Dimensions (mm) (kW) (kW) Cooling Heating (m³/h) (k Pa) dB(A) (kg) Width Depth Height (m) (m) (m) (kg) Ø (mm) fl. s. Max. Pipe Length** Max. Height Difference Max. Distance Length Refrigerant Charge Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power (kW) Cooling Heating Starting Current (A) Running Current (A) Max. Capacity Indoor Unit (%) Connectable Indoor Units (Number/Type) PQRY-P200YGM-A 22.4 25.0 4.7 5.3 4.56 16.5 46 263 990 550 1800 300 50 150 7.0 16 18 380-415V, 50Hz, 3 PQRY-P250YGM-A 28.0 31.5 4.7 5.4 5.76 19.5 47 266 990 550 1800 300 50 150 9.5 18 22 380-415V, 50Hz, 3 PQRY-P400YSGM-A 45.0 50.0 3,96 4.54 9.12 16.5 50 208+232 990 550 1800+1800 300 50 150 7+9.5 22 28 380-415V, 50Hz, 3 PQRY-P500YSGM-A 56.0 63.0 3.72 4.63 11.52 19.5 53 208+235 990 550 1800+1800 300 50 150 7+9.5 22 28 380-415V, 50Hz, 3 4.79 4.69 8.0 7.6 50-150 15 / 20-250 5.95 5.80 8.0 9.5 50-150 19 / 20-250 11.35 11.0 8.0 18.2 50-150 24 / 20-250 15.06 13.6 8.0 24.2 50-150 24 / 20-250 * Noise level measured at a position in 1 m in front of and 1 m above the unit in anechoic chamber. ** one-way The Big WR2 outdoor units are a combination of PQRY-P YGM-A (heat exchanger) and PQY-P01YGM-A (compressor) UNIT COMBINATION BIG PQRY Model Reference Necessary combination (Main unit + Sub unit) PQRY-P400YSGM-A PQRY-P500YSGM-A PQRY-P400YGM-A PQRY-P500YGM-A + PQY-P01YGM-A + PQY-P01YGM-A 77 Indoor Units Overview Capacity Type The wide range of high-quality indoor units enables a perfect integration in each room. All indoor units can be connected to Y-Series and R2-Series. Capacity code P 20 P 25 P 32 P 40 P 50 P 63 P 71 P 80 P 100 P 125 P 140 P 200 P 250 Cooling (kW) 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0 Heating (kW) 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5 Ceiling cassette (1-way airflow) PMFY-VBM-E ● ● ● ● Ceiling cassette (2-way airflow) PLFY-VLMD-E Ceiling cassette Euroraster (4-way airflow) PLFY-VCM-E ● ● ● ● ● ● ● ● ● ● ● ● ● Ceiling cassette (4-way airflow) ● ● ● ● PLFY-VAM-E Ceiling concealed (horizontal airflow)* PEFY-VML-E/VMH-E Ceiling concealed (variable airflow) PEFY-VMM-E ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● H-model L-model ● ● ● ● ● ● ● ● ● ● ● Ceiling concealed 100% fresh air ● PEFY-VMH-E-F ● Ceiling suspended ● PCFY-VGM-E Wall mounted PKFY-VAM-E Wall mounted PKFY-VGM-E/ PKFY-VFM-E ● ● ● ● ● ● ● ● ● ● Floor standing (cabinet type) PFFY-VLEM-E Floor standing (concealed type) PFFY-VLRM-E ● ● ● ● ● ● Advantage: For piping standard T-sections can be used. ● ● ● ● ● ● * L-model: low static pressure, H-model: high static pressure 78 Indoor units - Technical data 1-Way In-Ceiling Cassettes Compact size for smooth installation and maintenance Unit body size has been standardised for all models (H = 230 mm, W = 812 mm, D = 395 mm). Body weight is also only 14 kg for the main unit and 3 kg for the panel, making this unit one of the lightest in the industry. Quiet operation Newly developed airflow control system reduces noise level to only 27 dB(A) at the smallest unit. Drain water lift-up mechanism The drain pan can be positioned anywhere up to 600 mm from the ceiling´s surface. Fresh air intake The construction allows an intake of fresh air, two branch connections are prepared. PMFY 1-WAY IN-CEILING CASSETTES Model Reference Grille Cooling Capacity Heating Capacity Airflow Noise* Low/High Weigth incl. Grille Dimensions (Grille) Pipe Size Electrical Supply (V, Freq., Phase) Mac. Input Power Running Current (m³/h) (kW) (kW) Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height** Ø (mm) fl. s. (mm) (kW) (A) PMFY-P20VBM-E PMP-40BM 2.2 2.5 390 432 480 522 27/35 PMFY-P25VBM-E PMP-40BM 2.8 3.2 438 480 516 558 32/37 PMFY-P32VBM-E PMP-40BM 3.6 4.0 438 480 516 558 32/37 PMFY-P40VBM-E PMP-40BM 4.5 5.0 462 522 582 642 33/39 14 (17) 812 (1000) 395 (470) 230 (30) 6 12 220-240V, 50Hz, 1 14 (17) 812 (1000) 395 (470) 230 (30) 6 12 220-240V, 50Hz, 1 14 (17) 812 (1000) 395 (470) 230 (30) 6 12 220-240V, 50Hz, 1 14 (17) 812 (1000) 395 (470) 230 (30) 6 12 220-240V, 50Hz, 1 0.042 0.20 0.044 0.21 0.044 0.21 0.054 0.26 * The values given in the table reflect the measured noise level at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 79 Indoor units - Technical data 2-Way In-Ceiling Cassettes Compact dimensions Optimised installation height of only 335 mm for easy installation in low intermediate ceilings. Drain lift up mechanism All units are serial equipped with drain lift up mechanism for 600 mm lifting height. Lighter unit The light weight of only 23 kg (PLFY-P50 VLMD-E) simplifies the installation extremly. Coanda-Effect The draft-free airflow is adjustable by two air outlets. Quiet operation Optimised air-outlet-flow allows low noise pressure level of just 27 dB(A). Fresh air intake The construction of the 2-way cassette allows an intake of fresh air, one branch connection is prepared. (Optional parts required). PLFY 2-WAY IN-CEILING CASSETTES Model Reference Grille Cooling Capacity Heating Capacity Airflow (m³/h) Noise* Low/High Weight incl. Grille Dimensions (mm) (Grille) (kW) (kW) Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height** Ø (mm) fl. s. Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (A) PLFY-P20 VLMD-E CMP40VLW-B 2.2 2.5 390 480 570 27/33 PLFY-P25 VLMD-E CMP40VLW-B 2.8 3.2 390 480 570 27/33 PLFY-P32 VLMD-E CMP40VLW-B 3.6 4.0 390 480 570 27/33 PLFY-P40 VLMD-E CMP40VLW-B 4.5 5.0 420 510 630 29/36 PLFY-P50 VLMD-E CMP63VLW-B 5.6 6.3 540 660 750 31/37 PLFY-P63 VLMD-E CMP63VLW-B 7.1 8.0 600 780 930 32/39 PLFY-P100 PLFY-P125 VLMD-E VLMD-E CMPCMP100VLW-B 125VLW-B 11.2 14.0 12.5 16.0 1050 1440 1260 1620 1800 1500 1980 36/42 40/46 23 (29,5) 23 (29,5) 24 (30,5) 24 (30,5) 27 (34,5) 28 (35,5) 44 (56,5) 47 (59,5) 56 (69) 776 (1080) 776 (1080) 776 (1080) 776 (1080) 946 (1250) 946 (1250) 1446 1446 1708 (1750) (1750) (2010) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 634 (710) 606 (710) 335 (20) 335 (20) 335 (20) 335 (20) 335 (20) 335 (20) 335 (20) 335 (20) 335 (20) 6 6 6 6 6 10 10 10 10 12 12 12 12 12 16 16 16 16 220-240V, 220-240V, 220-240V, 220-240V, 220-240V, 220-240V, 220-240V, 220-240V, 220-240V, 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 0.075 0.075 0.075 0.085 0.086 0.105 0.156 0.186 0.280 0.37 0.37 0.37 0.42 0.43 0.51 0.74 0.88 1.35 * The values given in the table reflect the measured noise level at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 80 PLFY-P80 VLMD-E CMP100VLW-B 9.0 10.0 930 1110 1320 33/39 Indoor units - Technical data 4-Way In-Ceiling Cassettes standardised Euro-spacing Euro-Raster Compact dimensions (570x570 mm Euro-Raster) allows easy installation in raster-ceilings. Minimised installation height Optimised installation height of only 235 mm for easy installation in low intermediate ceilings. Lighter unit State-of-the-art materials allows lighter weights as of 15.5 - 17 kg and simplified installation. 4 servo-motors for 4 air-outlets Each air-outlet-flow is individual controlled by servomotors. A 4-way-cassette can easily modified to a 3-way or 2-way cassette. Serial equipped with fresh-air intake The construction of the Euro-spacing 4-way-cassette allows an intake of fresh air, one branch connection is prepared. Drain Pump for 500 mm hight difference PLFY 2-BY-2 IN-CEILING CASSETTES STANDARDISED EURO-SPACING Model Reference Grille Cooling Capacity Heating Capacity Airflow Noise* Low/High Weight incl. Grille Dimensions (Grille) Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current PLFY-P20VCM-E SLP-2AA 2.2 2.5 480 540 600 28/35 PLFY-P25VCM-E SLP-2AA 2.8 3.2 480 540 600 29/37 PLFY-P32VCM-E SLP-2AA 3.6 4.0 540 600 660 29/38 PLFY-P40VCM-E SLP-2AA 4.5 5.0 540 600 660 30/39 15,5 (18,5) 570 (650) 570 (650) 235 (20) 6 12 220-240, 50Hz, 1 15,5 (18,5) 570 (650) 570 (650) 235 (20) 6 12 220-240, 50Hz, 1 17 (20) 570 (650) 570 (650) 235 (20) 6 12 220-240, 50Hz, 1 17 (20) 570 (650) 570 (650) 235 (20) 6 12 220-240, 50Hz, 1 (Cooling) 0.05 0.05 0.06 0.06 (Heating) 0.05 0.05 0.06 0.06 (A) 0.23 0.23 0.28 0.28 (kW) (kW) (m³/h) Low Middle High dB(A) (kg) Width Depth Height** Ø (mm) fl. s. (mm) (kW) * The values given in the table for the noise level reflect the measurde at a position 1.5m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 81 Indoor units - Technical data 4-Way In-Ceiling Cassettes Compact dimensions Optimised installation height and lighter weight for easy installation in low intermediate ceilings. Drain lift up mechanism All units are serial equipped with drain lift up mechanism for 850 mm lifting height. Extreme quiet operation Optimised air-outlet-flow by inverter controlled turbo-fan with large diameter allows low noise pressure level of only 27 dB(A). Draft-free air-flow Up and down mechanism of the air-outlets provides fresh and natural air drafts. Flexible air flow rate 4-speed microprocessor controlled fan mode provides many airflow variations. Adjustable air flow rate by dip switch on controller board for different ceiling heights.The construction of the 4-way cassette allows an intake of fresh air, a branch connection is prepared. PLFY 4-WAY IN-CEILING CASSETTES Model Reference Grille Cooling Capacity Heating Capacity Airflow Noise* Low/High Weight incl. Grille Dimensions (Grille) Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (m³/h) (kW) (kW) Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height** Ø (mm) fl. s. (mm) (kW) (A) PLFYP32VAM-E PLP-6AA 3.6 4.0 660 720 780 840 27/31 PLFYP40VAM-E PLP-6AA 4.5 5.0 720 780 840 960 27/32 PLFYP50VAM-E PLP-6AA 5.6 6.3 720 780 840 960 27/32 PLFYP63VAM-E PLP-6AA 7.1 8.0 840 900 960 1080 28/33 PLFYP80VAM-E PLP-6AA 9.0 10.0 960 1080 1200 1320 30/37 PLFYP100VAM-E PLP-6AA 11.2 12.5 1140 1320 1500 1620 33/41 PLFYP125VAM-E PLP-6AA 14.0 16.0 1260 1440 1620 1740 35/43 22 (27) 840 (950) 840 (950) 258 (30) 6 12 220-240V, 50Hz, 1 0.12 0.59 22 (27) 840 (950) 840 (950) 258 (30) 6 12 220-240V, 50Hz, 1 0.14 0.68 22 (27) 840 (950) 840 (950) 258 (30) 6 12 220-240V, 50Hz, 1 0.14 0.68 24 (29) 840 (950) 840 (950) 258 (30) 10 16 220-240V, 50Hz, 1 0.16 0.78 24 (29) 840 (950) 840 (950) 258 (30) 10 16 220-240V, 50Hz, 1 0.18 0.86 32 (37) 840 (950) 840 (950) 298 (30) 10 16 220-240V, 50Hz, 1 0.30 1.43 32 (37) 840 (950) 840 (950) 298 (30) 10 16 220-240V, 50Hz, 1 0.34 1.64 * The values given in the table reflect the measured noise level at a position 1.5 m below the unit in anechoic chamber ** Needed installation height, in brackets: Visible grille height 82 Indoor units - Technical data Wall Mounted Systems PKFY-P-VAM-E Compact dimensions Wall mounted units are the ideal conception for less installation scope. Small outline dimensions of 295 mm and only 8,5 kg weight (Type VAM-E) provides easy installation above windows or doors. Quiet operation Optimised 4-speed fan allows low noise air-outlet-flow pressure. Shapely design The pleasing design makes it easy to blend in rooms or offices. An integrated fin closes the air outlet if the system is switched off. Easy to install – Easy to maintain Easy electrical connection after installation because of front cover installation box and reachable srews from front side. A very flexible installation and easy maintenance are ensured. All piping is connectable from right, left, bottom or back cover of the unit. PKFY WALL MOUNTED SYSTEMS Model Reference Cooling Capacity Heating Capacity Airflow Noise* Low/High Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (m³/h) (kW) (kW) Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height Ø (mm) fl. s. (mm) (kW) (A) PKFYP20VAM-E 2.2 2.5 294 312 336 354 32/36 PKFYP25VAM-E 2.8 3.2 294 312 336 354 32/36 PKFYP32VGM-E 3.6 4.0 480 570 630 690 33/41 PKFYP40VGM-E 4.5 5.0 480 570 630 690 33/41 PKFYP50VGM-E 5.6 6.3 540 600 660 720 34/43 PKFYP63VFM-E 7.1 8.0 900 PKFYP100VFM-E 11.2 12.5 1320 1200 39/45 1680 41/46 8.5 815 158 295 6 12 220-240V, 50Hz, 1 0.04 0.20 8.5 815 158 295 6 12 220-240V, 50Hz, 1 0.04 0.20 16 990 235 340 6 12 220-240V, 50Hz, 1 0.07 0.32 16 990 235 340 6 12 220-240V, 50Hz, 1 0.07 0.32 16 990 235 340 6 12 220-240V, 50Hz, 1 0.07 0.32 24 1400 235 340 10 16 220-240V, 50Hz, 1 0.12 0.55 28 1680 235 340 10 18 220-240V, 50Hz, 1 0.14 0.64 * The values given in the table reflect the measured noise level at a position 1 m in front of and 1 m below the unit in anechoic chamber 83 Indoor units - Technical data Floor or Ceiling Mounted Systems Extremly quiet – highest convenience Optimised air-outlet-flow and high-quality materials provides low noise pressure level of only 29 dB(A) (PCFY-P40VGM-E). Optimised air outlet pressure for variable ceiling heights All units are serial equipped with 4-speed microprocessor controlled fan mode to provide many airflow variations. Adjustable air flow rate by dip switch on controller board for different ceiling heights (max. 3.5 m). Optional drain pump The drain pump (optional part) can be connected from the left or the right. Easy to install Edgewise mounting provides easy and quick installation. Sidecovers can be removed. Up and down moving fin Up and down mechanism of the air-outlet fin provides fresh and natural air drafts. An integrated fin closes the air outlet if the system is switched off. Pleasing and slim The pleasing and slim ceiling conceiled units make it easy to blend in rooms or offices. PCFY FLOOR OR CEILING MOUNTED Model Reference Cooling Capacity Heating Capacity Airflow (m³/h) Noise* Low/High Weight Dimensions (mm) Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (kW) Low Middle 1 Middle 2 High dB(A) (kg) Width Depth Height Ø (mm) fl. s. (kW) (A) PCFY-P40VGM-E 4.5 5.0 480 600 660 720 29/38 PCFY-P63VGM-E 7.1 8.0 720 840 960 1080 32/39 PCFY-P100VGM-E 11.2 12.5 1080 1200 1380 1500 36/43 PCFY-P125VGM-E 14.0 16.0 1560 1680 1920 2100 37/44 27 1000 680 210 6 12 220-240V, 50Hz, 1 34 1310 680 210 10 16 220-240V, 50Hz, 1 37 1310 680 270 10 16 220-240V, 50Hz, 1 43 1620 680 270 10 16 220-240V, 50Hz, 1 0.10 0.46 0.13 0.60 0.16 0.73 0.24 1.10 * The values given in the table reflect the measured noise level at a position 1 m in front of and 1 m below the unit in anechoic chamber 84 Indoor units - Technical data Floor Standing Units (Concealed Type) Compact dimensions, optimised room utilisation The approved technology of the floor standing type is easy to integrate (depth only 220 mm) in offices and rooms and its architecture. Humidification mode To keep humidity constant it is possible to switch on dehumidification mode for fresh air. PFFY FLOOR STANDING UNITS (CONCEALED TYPE) Model Reference Cooling Capacity Heating Capacity Airflow Low/High Noise* Low/High Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (kW) (m³/h) dB(A) (kg) Width Depth Height Ø (mm) fl. s. (mm) (kW) (A) PFFY-P20VLRM-E PFFY-P25VLRM-E PFFY-P32VLRM-E PFFY-P40VLRM-E PFFY-P50VLRM-E PFFY-P63VLRM-E 7.1 2.2 2.8 3.6 4.5 5.6 8.0 2.5 3.2 4.0 5.0 6.3 720 / 930 330 / 390 330 / 390 420 / 540 540 / 660 720 / 840 34/40 34/40 35/40 38/43 38/43 40/46 18.5 886 220 639 6 12 220-240V, 50Hz, 1 0.04 0.19 18.5 886 220 639 6 12 220-240V, 50Hz, 1 0.04 0.19 20 1006 220 639 6 12 220-240V, 50Hz, 1 0.06 0.29 21 1006 220 639 6 12 220-240V, 50Hz, 1 0.065 0.32 25 1246 220 639 6 12 220-240V, 50Hz, 1 0.085 0.40 27 1246 220 639 10 16 220-240V, 50Hz, 1 0.10 0.46 * The values given in the table reflect the measured noise level at a position 1.5 m in front of and 1.5 m above the unit in anechoic chamber 85 Indoor units - Technical data Floor Standing Units (Cabinet Type) Compact dimensions, optimised room utilisation The approved technology of the floor standing type is easy to integrate (depth only 220 mm) in offices and rooms and its architecture. Control system Remote controllers can be integrated with the casing of the floor standing units. Wall mounted installation for remote controllers is not necessary. Serial equipped fresh air intake The construction allows an intake of fresh air, a branch connection is prepared, serial equipped air filter can be used. Humidification mode To keep humidity constant it is possible to switch on dehumidification mode for fresh air. PFFY FLOOR STANDING UNITS (CABINET TYPE) Model Reference Cooling Capacity Heating Capacity Airflow Low/High Noise* Low/High Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (kW) (m³/h) dB(A) (kg) Width Depth Height Ø (mm) fl. s. (mm) (kW) (A) PFFY-P20VLEM-E PFFY-P25VLEM-E PFFY-P32VLEM-E PFFY-P40VLEM-E PFFY-P50VLEM-E PFFY-P63VLEM-E 7.1 2.2 2.8 3.6 4.5 5.6 8.0 2.5 3.2 4.0 5.0 6.3 330 / 390 330 / 390 420 / 540 540 / 660 720 / 840 720 / 930 34/40 34/40 35/40 38/43 38/43 40/46 23 1050 220 630 6 12 220-240V, 50Hz, 1 0.04 0.19 23 1050 220 630 6 12 220-240V, 50Hz, 1 0.04 0.19 25 1170 220 630 6 12 220-240V, 50Hz, 1 0.06 0.29 26 1170 220 630 6 12 220-240V, 50Hz, 1 0.065 0.32 30 1410 220 630 6 12 220-240V, 50Hz, 1 0.085 0.40 32 1410 220 630 10 16 220-240V, 50Hz, 1 0.10 0.46 * The values given in the table reflect the measured noise level at a position 1.5 m in front of and 1.5 m above the unit in anechoic chamber 86 Indoor units - Technical data Ceiling Concealed Ducted Units Horizontal airflow Top flexibility 13 types with 2.2 kW up to 28.0 kW for flexible application. Compact dimensions Low casing height of only 225 mm (PEFY-VML) for easy installation in low air ducts. Maximum high static pressure up to 260 Pa PEFY-VMH with high static pressure (50 - 260 Pa) are optimised for long distance air ducts. Extremely quiet Low noise level of PEFY-VML only 25 dB(A). Easy maintenance Easy maintenance by the use of service port. Filter as standard for all PEFY-P VML types PEFY CEILING CONCEALED DUCTED UNITS (REAR OR BOTTOM SUCTION FOR VML-E UNITS) Model Reference Cooling Capacity Heating Capacity Airflow (m³/h) Ext. Static Pressure** Noise* Low/High Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (kW) Low Middle High (Pa) PEFY-P20 VML-E 2.2 2.5 288 348 474 5 PEFY-P25 VML-E 2.8 3.2 288 348 474 5 PEFY-P32 VML-E 3.6 4.0 288 348 570 5 dB(A) 25/36 25/36 18 720 550 225 6 12 220-240V, 50Hz, 1 0.05 0.24 18 720 550 225 6 12 220-240V, 50Hz, 1 0.05 0.24 (kg) Width Depth Height Ø (mm) fl. s. (mm) (kW) (A) PEFY-P40 VMH-E 4.5 5.0 600 PEFY-P50 VMH-E 5.6 6.3 600 PEFY-P63 VMH-E 7.1 8.0 810 PEFY-P71 VMH-E 8.0 9.0 930 25/40 840 50/100/150/ 200 27/34 840 50/100/150/ 200 27/34 1140 50/100/150/ 200 32/38 1320 50/100/150/ 200 32/39 18 720 550 225 6 12 220-240V, 50Hz, 1 0.07 0.32 44 750 900 380 6 12 220-240V, 50Hz, 1 0.19 0.88 45 750 900 380 6 12 220-240V, 50Hz, 1 0.19 0.88 45 750 900 380 10 16 220-240V, 50Hz, 1 0.24 1.12 50 1000 900 380 10 16 220-240V, 50Hz, 1 0.26 1.20 *The values given in the table for the noise level reflect the measurde at a position 1.5 m below the unit in anechoic chamber ** static pressure depends on the power supply 87 Indoor units - Technical data Ceiling Concealed Ducted Units Horizontal airflow Top flexibility 13 types with 2.2 kW up to 28.0 kW for flexible application. Maximum high static pressure up to 260 Pa PEFY-VMH with high static pressure (50 - 260 Pa) are optimised for long distance air ducts. Easy maintenance Easy maintenance by the use of service port. PEFY CEILING CONCEALED DUCTED UNITS (REAR SUCTION) Model Reference Cooling Capacity Heating Capacity Airflow Low/High Ext. Static Pressure** Noise* Low/High Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (kW) (m³/h) PEFY-P80 VMH-E PEFY-P100 VMH-E PEFY-P125 VMH-E PEFY-P140 VMH-E PEFY-P200 VMH-E PEFY-P250 VMH-E 28.0 9.0 11.2 14.0 16.0 22.4 31.5 10.0 12.5 16.0 18.0 25.0 4320 1080 / 1500 1590 / 2280 1590 / 2280 1680 / 2400 3480 (Pa) dB(A) 50/100/150/200 50/100/150/200 50/100/150/200 50/100/150/200 110/130/220/260110/130/220/260 52 35/41 34/42 34/42 34/42 45 (kg) Width Depth Height Ø (mm) fl. s. (mm) (kW) (A) 50 1000 900 380 10 16 220-240V, 50Hz, 1 0.32 1.47 70 1200 900 380 10 16 220-240V, 50Hz, 1 0.48 2.34 70 1200 900 380 10 18 220-240V, 50Hz, 1 0.48 2.34 70 1200 900 380 10 16 220-240V, 50Hz, 1 0.48 2.35 * The values given in the table reflect the measured noise level at a position 1.5 m below the unit in anechoic chamber ** static pressure depends on the power supply 88 100 1250 1120 470 10 18 380-415V, 50Hz, 3 0.99 1.62 100 1250 1120 470 10 22 380-415V, 50Hz, 3 1.23 2.00 Indoor units - Technical data Ceiling Concealed Ducted Units Variable airflow Optimised flexibility Variable air intake flow from bottom or backside provides optimised installation solutions. Compact dimensions – just 295 to 325 mm casing height Low casing height for easy installation in low air ducts with high quality ventilation requirements. Extremely quiet operation at high static pressure Optimised air-outlet-flow allows low noise pressure level of just 27 dB(A) with high static pressure up to 130 Pa. Filter as standard for all PEFY-P VMM types PEFY CEILING CONCEALED DUCTED UNITS (REAR OR BOTTOM SUCTION) Model Reference Cooling Capacity Heating Capacity Airflow PEFY-P20 PEFY-P25 PEFY-P32 PEFY-P40 PEFY-P50 PEFY-P63 PEFY-P71 PEFY-P80 VMM-E VMM-E VMM-E VMM-E VMM-E VMM-E VMM-E VMM-E (m³/h) Ext. Static Pressure** Noise* Low/High Weight Dimensions Pipe Size (kW) (kW) Low Middle High (Pa) dB(A) (kg) Width Depth Height Ø (mm) fl. s. (mm) Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (A) 2.2 2.5 360 432 510 30/50/ 100 27/32 2.8 3.2 360 432 510 30/50/ 100 27/32 3.6 4.0 450 540 630 30/50/ 100 28/35 4.5 5.0 600 720 840 30/50/ 100 31/37 5.6 6.3 720 870 1020 30/50/ 100 31/38 7.1 8.0 810 972 1140 30/50/ 100 31/38 8.0 9.0 870 1080 1260 30/50/ 100 32/39 9.0 10.0 870 1080 1260 30/50/ 100 32/39 PEFYP100 VMM-E 11.2 12.5 1380 1980 50/130 PEFYP125 VMM-E 14.0 16.0 1680 2400 50/130 PEFYP140 VMM-E 16.0 18.0 1770 2520 50/130 40/44 42/45 42/45 27 27 27 33 33 42 42 42 62 65 70 815 815 815 935 935 1175 1175 1175 1415 1415 1715 700 700 700 700 700 700 700 700 740 740 740 295 295 295 295 295 295 295 295 325 325 325 6 6 6 6 6 10 10 10 10 10 10 12 12 12 12 12 16 16 16 16 16 16 220220220220220220220220220220220240V, 240V, 240V, 240V, 240V, 240V, 240V, 240V, 240V, 240V, 240V, 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 50Hz, 1 0.15 0.15 0.17 0.19 0.20 0.22 0.25 0.25 0.29 0.40 0.42 0.73 0.73 0.81 0.92 0.98 1.07 1.15 1.15 1.34 1.90 1.95 * The values given in the table reflect the measured noise level at a position 1.5 m below the unit in anechoic chamber ** static pressure depends on the power supply 89 Indoor units - Technical data Fresh Air Intake Ceiling Concealed Ducted Units Highest convenience These ducted types are designed for 100% fresh air intake. Additional air handling units are not needed. Maximum high static pressure up to 220 Pa PEFY-VMH-E-F with high static pressure from 50 up to 220 Pa (at 230 V) are optimised for long distance air ducts. Easy maintenance Easy maintenance by the use of service port. Quiet operation at high static pressure Optimised air-outlet-flow allows low noise pressure level of only 33 dB(A) (type P80) with high static pressure up to 220 Pa. PEFY 100% FRESH AIR INTAKE Model Reference Cooling Capacity Heating Capacity Airflow Ext. Static Pressure** Noise* Low/High Weight Dimensions Pipe Size Electrical Supply (V, Freq., Phase) Max. Input Power Running Current (kW) (kW) (m³/h) (Pa) dB(A) (kg) Width Depth Height Ø (mm) fl. s. (mm) (kW) (A) PEFY-P80VMH-E-F 9.0 8.5 540 50/130/170/220 33/45 PEFY-P140VMH-E-F 16.0 15.1 1080 50/130/220/240 34/45 50 1000 900 380 10 16 220-240V, 50Hz, 1 70 1200 900 380 10 16 220-240V, 50Hz, 1 0.16 0.67 0.29 1.24 * The values given in the table for the noise reflect the levels measured at a position 1.5 m below the unit in anechoic chamber by 50/220Pa ** the static pressure depends on the power supply 90 City Multi Connection Kit Ab August/September 2005 neue auf kW-Basis forTypbezeichnung existing heat exchangers inInnengeräte*: recirculation mode PEAD-RP35/50/60/71 EA mit neuer A-Steuerung und neuer The extensive power range from 5.6 up to •* Fernbedienung (erweiterte Funktionen, z.B. Wochentimer Easy-Maintenance) 28.0 kW is und covered by four modules. The combination of several connection kits to Außengeräte: heat exchangers with additional circuits PUHZ-RP35/50/60/71 VHA provides higher power capacity levels*. The connection kit consists of a controller box including a special circuit board with microprocessor operation as well as of three temperature sensors, and is adopted and controlled by City Multi M-Net data bus. Included in delivery are the necessary electronic expansion valves (LEV) required to connect the external heat exchanger with the piping system. Besides the standard single remote controllers a central control system can be • • • • selected (e.g. G50). Also the external in- and outputs can be used for control. The connection kit can be integrated for operation in doorway air curtain systems, floor heating systems or water treatment systems. * Further information on request. F I A K J E C B D A - E Module Connection Kit F City Multi outdoor unit G Suction pipe H Liquid pipe I Customer´s control ventilation system J Customer´s heat exchanger K Ventilation unit L City Multi indoor unit H G L CONNECTION KIT Model reference Cooling Capacity Heating Capacity Airflow external Airtemperature (°C WB) Refrigerant Dimensions Controller Box Height x Width x Depth Pipe size Ø Set Temperature At Control Protection Class Weight Power Supply Operation Temperature Control Error Messages Accessories (not included in delivery) min - max (kW) min - max (kW) (m3/h) (mm) fl./s. (mm) (°C) (kg) (V, Phase, Hz) PAC-AH63M-G PAC-AH125M-G PAC-AH140M-G PAC-AH250M-G 5.6 - 7.1 6.3 - 8.0 1250 15-24 R410A 8.0 - 14.0 9.0 - 16.0 1500-2500 15-24 R410A 14.0 - 16.0 16.0 - 18.0 3000 15-24 R410A 16.0 - 28.0 25.0 - 31.5 4000-5000 15-24 R410A 382 x 326 x 117 10/16 382x326x117 10/16 382x326x117 10/16 382x326x117 10/22 14-30 IP24 7 220-240, 1, 50 14-30 14-30 14-30 IP24 IP24 IP24 7 7 7 220-240, 1, 50 220-240, 1, 50 220-240, 1, 50 Via selected City Multi remote controller External ON/OFF via customer´s thermostat Display operation status START/STOP-function via external signal of RLT system Setpoint specification via wired remote control Temperature limited by external ON/OFF signal of customer´s thermostat Via potential-free contact Wired remote control PAR-F27MEA 91 Close Control System PFD Series Mitsubishi Electric has designed a special series including two indoor units with high sensible cooling capacity for computer and technical equipment rooms. The big heat exchanger makes it possible to reach the SHF factor 0.93 of the sensible heat load. The low latent capacity makes the additional air humidification unnecessary. The switch tolerance is +-1K. The airflow of the units is in double-ground direction and both of them need less space due to its compact construction. The indoor unit PFD-P500VM-E provides 100% redundancy. The outdoor unit is equipped with a full inverter compressor with the advantage of very low starting current of just 8A. Long piping lengths of 120 m between indoor and outdoor units as well as the height difference of 50 m allow wide scope for planning purposes. 92 Close Control City Multi PFD-Series PFD INDOOR UNITS Model Reference Capacity (kW) Airflow Ext. Static Pressure Noise* Weight Dimensions (mm) Pipe Size Ø Electrical Supply Max. Input Power Running Current Outdoor Unit Cooling Heating (m3/h) (Pa) dB(A) (kg) Width Height Depth fl. (mm) s. (V, Freq., Phase) (kW) (A) (Type) PFD-P250VM-E 28.0 31.5 9600 120 59 380 1380 1950 780 10 22 380-415, 50, 3 2.5 5.0 PUD-P250YGM-A or PUHD-P250YGM-A PFD-P500VM-E 56.0 63.0 19200 120 63 520 1980 1950 780 16 28 380-415, 50, 3 5.0 9.0 PUHD-P500YGH-A The airflow is in double-ground direction PUD OUTDOOR UNITS Model Reference Capacity (kW) Airflow Noise* Weight Dimensions (mm) Total Pipe Length Max. Height Difference Refrigerant Charge Pipe Size Ø (mm) Electrical Supply Max. Input Power (kW) Running Current Cooling Heating (m3/h) dB(A) (kg) Width Height Depth (m) (m) (kg) fl. s. (V, Freq., Phase) Cooling Heating (A) PUD-P250YGM-A 28.0 – 12000 57 233 990 1840 840 150 50 9.5 10 22 380-415, 50, 3 7.72 13.0 PUHD-P250YGM-A 28.0 31.5 12000 57 233 990 1840 840 150 50 9.5 10 22 380-415, 50, 3 7.72 7.62 13.0 PUHD-P500YGM-A 56.0 63.0 24000 60 455 1990 1840 840 150 50 22.0 16 28 380-415, 50, 3 15.59 15.89 25.0 * The noise level is measured in 1 m in front of and 1 m above the unit. 93 City Multi System Control Standard Remote Controllers ● ● ● PAR-20MAA ● ● ● ● ● ● ● PAR-21MAA ● ● ● ● ● ● ● ● ● ● ● ● ● PAR-F27 MEA ● ● ● ● PAC-YT51CRA PAC-SE51CRA ● ● ● ● ● ● The remote controller PAR-20MAA to connect at the indoor unit, building of groups possible via separate bus-cable. 1 indoor unit individual, 1 group with 16 indoor units possible by two-wire signal lines. Easy to read, easy to operate display with direct on/off control and room temperature regulation on the front side. All other buttons are protected by a cover. On/Off timer. Temperature selection in 1°C scale. Error messages are displayed. Room thermometer is built into the remote controller. Switching to unit room thermometer possible. The remote controller PAR-21MAA to connect at the indoor unit, building of groups possible via separate bus-cable. 1 indoor unit individual, 1 group with 16 indoor units possible by two-wire signal line. Easy to read, easy to operate display with direct on/off control and room temperature regulation on the front side. All other buttons are protected by a cover. Temperature selection in 1°C scale. Error messages are displayed. Room thermometer is built into the remote controller. Switching to unit room thermometer possible. Multi language display. Convenient one week-timer for scheduling of 8 temperature settings per day/56 per week. Limit temperature setting possible (cooling/heating individually adjustable). Easy maintenance function in connection with standard and power inverter. Countdown timer. Button interlock for all buttons or with exception of on/off button. The remote controller PAR-F27 MEA to connect at the City Multi Databus System, easy building of groups by addressing. 1 indoor unit individual, 1 group with 16 indoor units. Easy to read, easy to operate display with direct on/off control and room temperature regulation on the front side. All other buttons are protected by a cover. Extensive timer function. Permanently working on/off day timer, off-time function and the interlock possibility for all control functions. on/off function can be left unblocked if needed. Temperature selection in 1°C scale. Auto-diagnosis display: A microcomputer constantly monitors operation to keep the units running smoothly. In case of errors the temperature setting display changes to an autodiagnosis display that shows alternately the inspection mode and the address code. Room thermometer is built into the remote controller. Switching is possible to indoor unit room thermometer. Limit temperature setting and switching off the room temperature display possible. To simplify operation of the system e. g. for hotel applications, the range of controls has been limited to START/STOP, room temperature and fan speed. Room temperature sensors is integrated into remote controller. Can operate all types of indoor units. 1 indoor unit individual, 1 group with 16 indoor units. PAC-YT51CRA – manually grouping by two-wire signal lines. PAC-SE51CRA – grouping by addressing via data bus. As this system has no operation mode switching, test operation, self-diagnosis or linked setting functions, it should always be used in conjunction with the PAR-F27MEA or other centralized controller. 94 City Multi System Control – Infrared-, On/Off- and Group Remote Controllers – Timer Infrared Remote Control PAR-FL32MA-E (signal sender) and PAR-FA32MA-E (signal receiver) PAR-FL32MA-E PAR-FA32MA-E ● It operates in a group system without requiring address settings ● If errors occur, the error message is shown by a LED flash count ● 1 indoor unit individual / 1 group with 16 indoor units by two-wire signal lines On/Off Remote Controller PAC-YT40 ANRA ● ● Up to 16 groups possible to control Good value solution for On/Off operation of up to 50 indoor units PAC-YT40 ANRA Group Remote Control PAC-SC30 GRA ● Easy to read, easy to operate display Temperature selection in 1°C scale ● Auto-diagnosis display: A microcomputer constantly monitors operation to keep the units running smoothly. In case of errors the temperature setting display changes to an auto-diagnosis display that shows alternately the inspection mode and the address code. ● 8 indoor units individual / max. 16 indoor units in 8 groups ● PAC-SC30 GRA Programme Timer PAC-YT32 PTA ● ● ● One-week scheduling by remote controller Night set-back function Control for PAR-F27 MEA (1 indoor unit individual / 1 group with 16 indoor units) PAC-YT32 PTA 95 City Multi System Controll – System Remote Controllers – System Timer System Remote Controller PAC-SF44 SRA ● PAC-SF44SRA All functions of a standard controller are available (e. g. the settings of air outlet/ventilation flaps/ventilation level etc.) ● Limited room air temperature selection ● External input/output ● Saving of error messages ● 50 indoor units individual/max. 50 indoor units with 50 groups ● Lock-out of functions for PAR-F27 MEA System Timer PAC-YT34STA ● Directly connected to the M-Net data-bus 50 groups/max. 50 indoor units possible ● Timer-controlled operation mode ● Timer-controlled set temperature ● 9 timer programmes can be saved ● Lock-off selection (on/off, operation mode, temperature) ● Minimal set-up circuit time 5 minutes, 16 times per day ● PAC-YT34STA 96 City Multi System Control – Central Remote Controller with Web-Function G-50A-PRO and GB-50A-PRO: Advantages overview ● Simple and flexible The central controller G(B)-50A-PRO is equally suitable for small and large systems. Up to 50 units can be controlled by G(B)-50A-PRO. Max. 40 central remote controllers can be connected to one system to operate and monitor up to 2.000 indoor units. Thus you receive a simple central remote control for complex systems. G-50A-PRO In addition a local service is at the LCD display and integrated keyboard possible. ● Web-Browser Use a standard web browser on your PC, e.g. Microsoft Internet Explorer® (from version 5 on), to operate and monitor the air conditioning unit, which is connected to your local Intranet, in comfort. ● Integrated software The easy to understand, multi-language, graphically prepared operating software is already integrated in the G(B)-50A-PRO. This represents Mitsubishi Electric’s own innovation and is not Windows-based. It is therefore impossible for hackers to spy in your system data. ● Always up-to-date By software upgrades the G(B)-50A-PRO can be adjusted in case of new or changed system conditions. GB-50A-PRO Without display, power supply unit is not needed ● Password levels You can safeguard against unauthorised access to the air conditioning system on operating levels, which are individually protected by passwords of your choice. ● Remote access via ISDN and LAN (optional) You can also operate your air conditioning system with your PC by means of BTX-1000II router via your local intranet or phone connection. ● Automatic error message (optional) In case of errors the G(B)-50A-PRO sends a message including the most important information via email to addresses of your choice (via SMS also possible). To activate this function the router BTX-1000II is requested. INCLUDED IN DELIVERY Type G-50A-PRO GB-50A-PRO Descriptions programmed for clients demand software web-function and annual schedule included ● Software TG2000 (optional) The advanced TG2000 hard- and software enables an easy maintenance and customized operation of the air conditioning system. OPTIONAL PARTS Type PAC-SC50KUA BTX-1000II Descriptions Power supply for G-50A-PRO Router according to ME specification + installation is required depending to clients demands OPTIONAL FUNCTIONS Pin Code Power consumption calculation Auto alarming Virtual remote controll BACnet Load Control SPS connection TG2000 Software incl. PC, keyboard and mouse Required optional parts TG2000 Customer’s ISDN-access and BTX-1000II TG2000 + POWER RAIL SPS from Mitsubishi Electric Customer’s Monitor For detailed information kindly contact our technical consultant. 97 City Multi System Control – LonWorks® Interface – Maintenance Tool Lon Works® Interface L-MAP02E Easy connection of City Multi Systems through L-MAP02-E, the LonWorks® M-Net protocol converter, the total system requirements of engineers and end-users can be met more effectively and simply. ● 1 LonWorks® Interface manages 50 indoor units. ● L-MAP02-E Maintenance Tool CMS-MNF-B ● Using Maintenance Tool is the easiest way for controlling, servicing and operating the City Multi system. ● All system information and error messages can be displayed on personal computer screen*, can be saved and also changed. ● The connection to modem enables a remote monitoring. ● The Maintenance Tool CMS-MNF-B consists of converter box, adapter and software. RS-232 cable is needed. * Windows 3.1 or Windows 95, Pentium 75 MHz or more, 16 MB RAM, 10 MB free fixed-disk storage 98 VRF Accesssories Control Accessories Model Reference PAC-SE40TS-E PAC-725AD PAC-SA88HA-E PAC-SE55RA-E PAC-SF46EPA Description External temperature sensor Adaptor cable for remote monitoring (pack of 10 pcs) Adaptor cable for remote monitoring (pack of 1 pc) Remote indicator ON/OFF Transmission booster Indoor / Outdoor Units Model Reference PLFY-P-VAM-E PAC-SG06SP-E PAC-SG01KF-E PAC-SG03TM-E Description Air outlet shutter plate High efficiency filter for PAC SG03TM-E Multifunction casement PLFY-P-VLMD-E PAC-KH110F Fresh air access PCFY-P-VGM-E PAC-SE80KF-E PAC-SE81KF-E PAC-SE82KF-E PAC-SE84DMA-E PAC-SE85DMA-E PAC-SH17DM-E High efficiency filter for PCFY-P40 VGM-E High efficiency filter for PCFY-P63/100 VGM-E High efficiency filter for PCFY-P125 VGM-E Drain pump for PCFY-P40 VGM-E Drain pump for PCFY-P63 VGM-E Drain pump for PCFY-P100/125 VGM-E PEFY-P-VML/VMH/VMH-E-F PAC-KE04DM-F PAC-KE32LAF-F PAC-KE86LAF PAC-KE88LAF PAC-KE89LAF PAC-KE85LAF PAC-KE63TB-F PAC-KE80TB-F PAC-KE140TB-F PAC-KE250TB-F Drain pump for PEFY-P-VMH-E Replacement filter for PEFY-P20/25/32 VML-E Optional filter for PEFY-P40/50/63 VMH-E Optional filter for PEFY-P71/80 VMH-E Optional filter for PEFY-P100/125/140 VMH-E Optional filter for PEFY-P200/250 VMH-E Filter box for PEFY-P40/50/63 VMH-E Filter box for PEFY-P71/80 VMH-E Filter box for PEFY-P100/125/140 VMH-E Filter box for PEFY-P200/250 VMH-E PEFY-P-VMM-E PAC-KE03DM-F PAC-KE32EDF-F PAC-KE50EDF-F PAC-KE80EDF-F PAC-KE125EDF-F PAC-KE140EDF-F Drain pump for PEFY-P-VMM-E Round duct flange for PEFY-P20/25/32 VMM-E Round duct flange for PEFY-P40/50 VMM-E Round duct flange for PEFY-P63/71/80 VMM-E Round duct flange for PEFY-P100/125 VMM-E Round duct flange for PEFY-P140 VMM-E PU(H)Y-P/PURY-P-YGM-E PAC-KBU04MT-F High static pressure motor 30/60 Pa Refrigerant Pipes CMY-R160-J CMY-Y102S-G* CMY-Y102L-G* CMY-Y202-G* CMY-Y302-G* CMY-Y104-G* CMY-Y108-G* CMY-Y1010-G* Junction pipe kit for BC-Controller T-Branch 18/10** T-Branch 22/12** T-Branch 22/16** T-Branch 35/18** Header (4 branch) Header (8 branch) Header (10 branch) * Standard T-Branch can be used ** Various restricted fittings included 99 Lossnay Ventilation Systems with heat recovery The advanced Lossnay range of ventilation units extract stale air and replace it with fresh air saving energy in the process with their very effective heat energy recovery system. This system utilises almost all the available cooling and heating energy, cutting power consumption by between 40% and 70%. This is made possible by the special plate-fin paper diaphragm heat exchanger. The superbly efficient heat recovery system enables to minimise the power consumption of air conditioning systems, thus significantly reducing overall installation costs. In addition to this the system also humidifies or dehumidifies the fresh air fed into the room, as required. Lossnay ventilation units are suitable for connection with Mr. Slim and City Multi outdoor units and can be installed in all modern buildings, creating an ideally healthy living and working environment. 100 Lossnay VL-Series Wall Mounted System Model VL-100 LOSSNAY-VL-SERIE Model Reference Fan stage Electrical Supply (V, Phase,Hz) Power Consumption VL-100U-E 220-240, 1, 50 (W) Airflow (m3/h) Noise* Efficiency dB(A) (%) Weight Dimensions (kg) (mm) Duct Size (mm) Low High Low High Low High Low High Width Depth Height 23 26 65 105 29.5 39 77 70 6.5 620 168 265 2 x 75 ø To install the units of the Lossnay Series VL-100 only 2 x 75 mm diameter bores are necessary. ● The units operate very quietly, selection between two fan speed levels (low/high) is possible. ● The unit will be switched on/off by pull string. ● Supply and return air ducts and protective caps against invading rain water are included in delivery. * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Lossnay LGH-Series Ceiling Suspended Systems Model LGH-40ES-E LOSSNAY-LGH-SERIE Model Reference Fan stage Electrical Supply (V, Phase,Hz) Power Consumption (W) Max. Running Current (A) Airflow (m3/h) Static Pressure (Pa) Noise* dB(A) Efficiency sensibel (%) Efficiency latent (%) Weight Dimensions (kg) (mm) Duct Size (mm) LGH-40ES-E 220-240, 1, 50 Low High Low High Low High Low High Low High Low High Low High Width Depth Height 88 138 0.4 0.6 250 400 10 40 33 42 70 60 52 45 25 900 693 255 2 x 200 ø ACCESSORIES FOR LGH-40ES-E Model Reference PZ-03SLP-E Description Switch on/off and airflow levels Compact Design The space saving ceiling suspended systems can be installed easily in various rooms due to the compact design. ● The simultaneous intake/exhaust of air with the cross flow heat exchanger enables high energy efficiency. ● The compact construction, just 255 mm height, enables easy installation and makes subsequent mounting possible. ● Maintenance and service friendly ● Refined design with outflow directly below the unit, thus avoids discomfort from air draft ● Switch on/off optional * The values given in the table for the noise level reflect the levels measured at a position 1 m in front of and 0.8 m below the unit in anechoic chamber Operating conditions Losssnay Systems VL-Series: t =10° to 40° C, ϕ = 60% maximum LGH-Series: t =10° to 40° C, ϕ = 80% maximum 101 Lossnay LGH-Series Ceiling Concealed Ducted Systems Models LGH 15 to 200 RX Saves between 20% and 50% of the energy that would otherwise be lost by ventilation ● Saves up to 30% on initial capital costs of heating and cooling plant due to Lossnay’s ability to utilise heating or cooling energy that would otherwise be wasted ● Automatically humidifies or dehumidifies incoming air to match required interior conditions ● Supply air and exhaust air are kept strictly separated to ensure inbound air is always fresh ● Supply air is heated or cooled as required to match room conditions ● Provides comfortable ventilation through introduction of fresh air, helping to provide a healthy working environment ● Minimal Maintenance ● Easily replaced Lossnay element LOSSNAY-LGH-SERIES Model Reference Electrical Supply (V,PHASE,Hz) Max. Running Current (A) Power Consumption (W) Airflow (m3/h) Static Pressure (Pa)* Noise** dB(A) Efficiency % Weight (kg) Dimensions (mm) Duct Size (mm) Fan stage Low Medium Extra High*** Low Medium Extra High*** Low Medium Extra High*** Low Medium Extra High*** Low Medium Extra High*** Width Depth Height LGH 15 RX 4 LGH 25 RX 4 LGH 35 RX 4 LGH 50 RX 4 LGH 65 RX 4 LGH 80 RX 4 LGH 100 RX 4 LGH 150 RX 4 LGH 200 RX 4 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 220-240,1,50 0.45 45 63 92 110 150 150 35 60 95 22 24 26 81 77 77 17 610 780 275 100ø 0.49 52 85 103 165 250 250 25 50 80 22 25 26.5 83.5 78 78 21 735 780 275 150ø 0.79 97 154 169 230 350 350 25 70 150 23 28 31 84 79 79 30 874 888 317 150ø 0.95 123 193 204 350 500 500 30 60 150 23.5 29.5 33 82 77 77 33 1016 888 317 200ø 1.4 185 270 295 500 650 650 30 50 110 27 32.5 34.5 79 76 76 46 954 908 388 200ø 1.7 290 340 365 670 800 800 70 100 140 30 32 33.5 80.5 78 78 61 1004 1164 398 250ø 2.1 365 440 455 870 1000 1000 80 100 160 31.5 34 36 81 79 79 69 1231 1164 398 250ø 3.3 575 670 720 1250 1500 1500 70 100 140 32.5 35.5 36.5 81.5 79 79 124 1004 1164 800 250/270ø 4.3 755 910 945 1650 2000 2000 65 90 150 35 37 39 81.5 79 79 140 1231 1164 800 250/270ø * Refering to the airflow in the table ** The values given in the table for the noise level reflect the levels measured at a position 1.5 m below the unit in anechoic chamber *** Extra high ventilation step to increase static pressure ACCESSORIES FOR LGH-RX MODELS Model Reference PZ-41SLB PZ-52SF Description Wired remote control for single operation / group 1-15 M-Net Wired remote control for operation in City Multi systems (single / group 1-16) OPTIONAL AIR CLEANING FILTER EU-G7 CLASS Model Reference PZ-15RFM PZ-25RFM PZ-35RFM PZ-50RFM PZ-65RFM PZ-80RFM PZ-100RFM 102 Quantity Per Set 1 2 2 2 2 2 2 LGH-RX-Model LGH 15 RX 4 LGH 25 RX 4 LGH 35 RX 4 LGH 50 RX 4 LGH 65 RX 4 LGH 80 RX 4 LGH 100 RX 4 Roof Top Systems PRH-Series R407C Mitsubishi Electric has designed the PRH-Series for an installation on the roof, as a self-contained and weatherproof system for high performance operation. The distribution of the air is effected via ventilations slot in the ceilings which can be installed almost invisible. This concealed ducted system is compatible with Mr. Slim and City Multi controls and therefore it is possible to connect. The Roof Top Systems stands for economy, smart design and a high degree of flexibility. 103 PRH-P200/250MYA PRH-P400/500MYA PRH-P-MYA ROOF TOP-SYSTEMS Outdoor Unit Cooling Capacity Heating Capacity Refrigerant Charge Power Supply Airflow direction Airflow internal Static Pressure Airflow external Weight Dimensions (mm) (kW) (kW) (V, Phase,Hz) internal m3/h Pa m3/h (kg) Width Depth Height PRH-P200MYA 20.9 23.7 4200 100 11100 407 2000 926 1715 PRH-P250MYA 26.0 30.5 PRH-P400MYA PRH-P500MYA 41.8 52.0 47.4 61.0 R407C 380/400/415 V, 3, 50 Hz factory setting lateral blow out, adjustable blow out upturned 5400 8400 10800 100 200 200 11100 2 x 11100 2 x 11100 412 depends on system 2000 2000 2000 926 2130 2130 1715 1735 1735 Installation example Operating range ● ● Cooling: Indoor Outdoor Heating: Indoor Outdoor 104 27° C 35° C 20° C 7° C (DB), 19° C (WB) (DB) (DB), (DB), 6° C (WB) Room Air Dehumidifier MJ-E16VX The best solution to rush the drying process of the laundry hanging on the line in house or flat is the dehumidifier from Mitsubishi Electric. The condensed humidity does not arise anymore. The energysaving and environmentfriendly room air dehumidifier can be flexible placed everywhere because of its light and compact design. FEATURES OF MJ-E16VX ● Practical carrying handle providing comfortable transport ● Easy to understand LCD-display for an easy operation ● Control function for operation mode, timer, water tank, process function and relative humidity ● Humidistat ● Integrated timer for 1-9 hours ● Three operation modes for low, high or auto● ● ● ● ● ● operation Portable 4 l water tank Sight-window for water-level check Overflow protection Direct condensate outlet by built-in short pipe Air-cleaning filter Auto-restart after power failure SPECIFICATIONS OF MJ-E16VX Dehumidifying Capacity per day (l) Water Container (l) Weight (kg) Dimensions Height x Width x Length (mm) Power Cunsumption (W) Power Supply (V, Phase, Hz) Operating Temperature min - max Compressor Type Refrigerant Charge R134a (g) Noise dB(A) 16.0 4.0 11.7 570 x 384 x 187 275 220-240, 1, 50 1° – 35°C Rotary 120 37-41 105 The Company reserves the right to make any variation in specification to the equipment described or to withdraw or replace products without prior notification or public announcement. Mitsubishi Electric is constantly developing and improving its products. All descriptions, illustrations, drawings and specifications in this publication present only general particulars and shall not form part of any contract. All goods are supplied subject to the Company’s General Conditions of Sale, a copy of which is available on request. MITSUBISHI ELECTRIC EUROPE B.V. Air Conditioning Division Gothaer Str. 8 D-40880 Ratingen Germany Phone: +49 2102 / 486-1892 Fax: +49 2102 / 486-7910 www.mitsubishi-electric-aircon.de Material number 192050 © 08/2006