Buck-boost Converter 3-3-1 Circuit diagram and key

advertisement
Buck-boost Converter
3-3-1
Circuit diagram and key waveforms
iD
iS
IRF150
Vg
D
iL
+
L
vo
C
vL
-
R
+
io
(a)
vo
+
Vg
L
vL
-
vo
L
R
+
vL
-
C
(b)
vL
Vg
C
+
R
+
(c)
A
t
B
- Vo
iL
iL,max
∆iL
iL,min
t
DT
(d)
(1-D)T
iL,max
iD
iL,min
t
ic
t
-Vo/R
C
vo
∆vo
t
Figure 3-3 (a) Buck-boost converter (b) switch on for a time duration DT (c) switch off for a
time duration (1-D)T (d) key waveforms.
3-3-2 Circuit description and operation
Circuit description. The three basic dc-dc converters use a pair of switches, usually one
controlled (eg. MOSFET) and one uncontrolled (ie. diode), to achieve unidirectional power
flow from input to output. The converters also use one capacitor and one inductor to store
and transfer energy from input to output. They also filter or smooth voltage and current.
The dc-dc coverters can have two distinct modes of operation: Continuous
conduction mode (CCM) and discontinuous conduction mode (DCM). In practice, a
converter may operate in both modes, which have significantly different characteristics.
Therefore, a converter and its control should be designed based on both modes of operation.
However, for this course we only consider the dc-dc converters operated in CCM.
Circuit Operation. When the switch is on for a time duration DT, the switch conducts the
inductor current and the diode becomes reverse biased. This results in a positive voltage vL =
Vg across the inductor. This voltage causes a linear increase in the inductor current iL. When
the switch is turned off, because of the inductive energy storage, iL continues to flow. This
current now flows through the diode, and vL = -Vo for a time duration (1-D)T until the switch
is turned on again.
Vo
, ∆iL, and ∆vo
Vg
Assumptions made about the operation of the converter are as follows:
• The circuit is operating in the steady state
• The circuit is operating in the CCM
• The capacitor is large enough to assume a constant output voltage
• The component are ideal
3-3-3 Analytical expressions for
Equating the integral of the inductor voltage over one time period to zero (Volt-second
balance) yields
∫
T
0
v L dt =
∫
t on
0
t off
v L dt + ∫ v L dt = 0
0
V g × DT + ( −Vo ) × (1 − D )T = 0
Vo =
D
Vg
1− D
or
Vo
D
=
Vg 1 − D
Assuming a lossless circuit, Pg = Po,
Therefore
V g I g = Vo I o
And
I o V g (1 − D)
=
=
I g Vo
D
For a buck-boost converter, it is obvious that
I L = I g + Io
1 DT
v L dt
L ∫0
1
= [ Shaded area under waveform v L (Area A)]
L
1
= V g × DT
L
∆i L =
From ∆iL we can obtain iL,min and iL, max
∆i L
2
∆i
= IL + L
2
i L ,min = I L −
i L ,max
To obtain the average inductor current, we can use this relationship
I D = I o = (1 − D) I L
Therefore
IL =
Io
Vo
=
(1 − D) (1 − D) R
(2-14)
The peak-peak output voltage ripple, ∆vo. From the information of the capacitor
current, ic, we can obtain ∆vo.
∆vo = ∆vc =
1
ic dt
C∫
1
[Shaded area under waveform ic ]
L
1 V
= × o × DT
C R
=
therefore
∆vo =
1 Vo
× × DT
C R
3-3-4 CCM/DCM boundary condition
Being at the boundary between the continuous and the discontinuous mode, by definition, the
inductor current iL goes to zero at the end of the off period. At this boundary, the average
inductor current is
∆i
IL = L
2
the minimum inductor current, iL, min = 0 and the maximum inductor curren iL, max = ∆iL.
vL
Vg
iL
DT
(1-D)T
t
-Vo
We know that for buck-boost converters I D = (1 − D) I L = I o =
∆i L =
Vo
and
R
1
1
V g DT = Vo (1 − D)T .
L
L
∆i L
, can be used to determine the combination
2
of L, f and R that will result in CCM. The minimum load current required for CCM operation
is:
∆i
IL = L
2
but I o = (1 − D) I L
Equation at the CCM/DCM boundary, I L =
IL =
Io
(1 − D)
Io
1
=
Vo (1 − D)T
(1 − D) 2 L
1
∴I o ,min =
Vo (1 − D) 2 T
2L
If the desired switching frequency f and load resistance R are established, the minimum
inductor current required for CCM is:
IL =
∆i L
2
Vo
1
=
Vo (1 − D)T
R(1 − D) 2 L
(1 − D) 2 T × R
∴ Lmin =
2
2
(1 − D) R
=
2f
If the desired value of the inductor L and the load resistance R are established, the minimum
switching frequency required for CCM is
(1 − D) 2 R
f min =
2L
If the desired switching frequency and the value of the inductor L are established, the
minimum load resistance required for CCM is
2 fL
Rmin =
(1 − D) 2
-tammat-
Download