Riparo Series Installation SINCE 1923 READ AND FOLLOW ALL SAFETY INSTRUCTIONS When using electrical equipment, basic safety precautions should always be followed, including: 1. Do not mount near gas or electric heaters. 2. Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. 3. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 4. Do not use this equipment for anything other than intended use. 5. All servicing should be performed by qualified service personnel only. Save these instructions! Wall or ceiling installation Light diffusion in wall installation using the supplied reflecting “Spoiler” Screws and washers not supplied Water-proof cap This unit is intended to be connected to 3/4”conduit with the supplied UL listed conduit fitting. Emergency, Self-Diagnostic should be wired inside the unit. Light diffusion in ceiling installation without reflecting “Spoiler” Riparo Mule Lighting, Inc. 46 Baker Street Providence, RI 02905 800 556-7690 P 401 941-2929 F www.mulelighting.com Riparo Series Installation SINCE 1923 Black - Orange - Red = L White = N To the mains Pink & Yellow Connected emergency ON Notconnected emergency OFF Violet & Yellow Connected Self-Diagnostic OFF Notconnected Self-Diagnostic ON Diagnostics Information Riparo Auto-test performs self-diagnosis tests at regular intervals defined by a preset timer. Availability tests are performed once a month, while battery autonomy is tested once every 26 weeks. The test cycle starts as soon as the lumlnaire is connected to the power supply (see wiring diagram). If the various luminaires in your installation are not connected to the power supply simultaneously, self-diagnostic tests will be performed at different times. The emergency light is on for 10 minutes after resumption of AC power to the unit. LED INDICATIONS: The LED on the front of the unit indicates correct connection and power ON status, while also providing diagnostic information acquired during the test cycles. Flashing red Red Battery or circuit Flashing yellow Yellow Lamp Green Normal Emergency inhibited Malfunction Test inhibited Malfunction Function A full autonomy test occurs every 26 weeks. Technical Information • Suitable for Damp and Wet location. • Ambient temperature: 10°C(50°F) minimum, 40°C(104°F) maximum. • Ready for installation on flammable surfaces. • Automatic recharge circuit fully regulated by an electronic voltage/current sensing unit. Mule Lighting, Inc. 46 Baker Street Providence, RI 02905 800 556-7690 P 401 941-2929 F www.mulelighting.com