HAKEL SURGE REDUCTION FILTER – HKSF SERIES Lightning Surges Lightning surges are characterized by high rate of current rise (di/dt) and high rate of induced voltage rise. This extreme rapid rises are the main causes of damage to sensitive and critical equipment resulting in down time and in some occasions massive unforeseen financial losses DOUBLE PROTECTION EQUIPMENT WITH HIGH DISCHARGE POWER AND LOW PROTECTION LEVEL (Up) Surge Reduction Filters Hakel’s comprehensive range of HKSF series arresters incorporating two port devices with built-in primary and secondary protection complete with surge reduction filter provides massive energy diversion and voltage clamping with stable and precise filtering features. These arresters should be installed prior to the sensitive equipment to be protected, virtually guaranteeing overvoltage protection against lightning surge which is the main cause of damage to sensitive and critical equipment such as advanced medical equipment and telecommunication equipment. Hakel HKSF series arrester encompasses 32A up to 200A for single phase and three phase. current rating series arresters are available upon request. Hakel HKSF high surge rating series arresters are suitable for highly exposed areas. Higher Highly effective two ports device with in-built primary and secondary transient protection stages complete with series surge filter ensures the following: * High performance 3 stages surge reduction * Significant reduction in residual voltage * Dramatically reduce di/dt and dv/dt up to 1000 times less reaching the sensitive equipment * Active MOV technology with high overvoltage withstand complying with IEC standard and UL1449 * Indoor and Outdoor (IP55) versions * Breaker incorporated to facilitate maintenance and replacement without power interruption * Audio and visual indication for arrester operational status * 5 years’ warranty Surge and Abnormal Voltage Protection Primary protection is provided by the high current rating (KA) varistor which is incorporated with mechanical fault indication. Secondary and N-E protection are also provided in this design. Wide range of voltages for primary protection manifested in our SPC3 series cater for abnormal voltage variation that can occur at site. This fault is normally due to voltage regulation or wiring fault such as open neutral. The primary and secondary protection cover nominal voltage of 220V~240V with 280V maximum voltage variation and a higher voltage range ensure protection against abnormal voltage up to 480V. Mode of Protection Hakel HKSF series arrester provides protection in common mode and differential mode for both single phase and three phase Operation Status Hakel HKSF series arrester provides detailed operational status for primary and secondary protection as well as power supply. This alerts the user of any presence of damage or defective arrester. The alarm can be deactivated with a latched switch. Filtering Hakel HKSF series arresters provide extreme suppression of voltage levels of high energetic impulses which come into the protected equipment from the L.V. power distribution side. The combination also ensures an attenuation of high frequency noise levels of a minimum 50dB at 5MHz in the band of 0.1 to 30MHz. Hakel HKSF series arresters are available in various ranges as indicated below: Type HKSF32-1 HKSF32-3 HKSF40-1 HKSF40-3 HKSF63-1 HKSF63-3 HKSF100-3 HKSF125-1 HKSF125-3 HKSF150-3 HKSF200-3 Nominal Voltage L-N System 220-277 220-277 220-277 220-277 220-277 220-277 220-277 220-277 220-277 220-277 220-277 1Ø2W+E 3Ø4W+E 1Ø2W+E 3Ø4W+E 1Ø2W+E 3Ø4W+E 3Ø4W+E 1Ø2W+E 3Ø4W+E 3Ø4W+E 3Ø4W+E Nominal Amp KVA@ 415V Imax (KA) 32 32 40 40 63 63 100 125 125 150 200 7.6 23 15 45 15 45 72 86 90 107 140 120 300 120 300 120 300 300 300 300 300 300 Dimensions (mm) L D H 500 300 150 500 300 210 500 300 150 600 400 210 500 300 150 600 400 210 600 400 210 500 300 150 800 600 210 800 600 210 800 600 210 HAKEL SURGE REDUCTION FILTER - HKSF … TECHNICAL DATA Model Design Nominal Voltage Maximum Permissible Voltage Current Rating Overload / Short Circuit Protection Power System Operating / Respond Time Primary Protection Total Surge Protection Specific Energy Nominal discharge current Neutral to Earth Protection Maximum Discharge Current Specific Energy Secondary Protection Discharge Current Multisurge Capability Voltage protection level at Uoc 6kV Surge Counter Alarm, Remote Indication Status Indication Configurable Audio / Visual indication Surge Filter Assymetrical Attenuation Band Stop Filter Inrush Damping Enclosure Environment Rating Operating Conditions Enclosure Withstand Surge Rated to Meet * for high ampere rating upon on request. Authorized Distributor: HKSF -1 HKSF -3 1 Phase 3 Phase 220-277Vrms, 50/60Hz 320/484V 32A, 40A,63A,100A, 125A, 160A, 200A * … circuit breaker 3P Y 4W+G - TT, TN-S, TN-C, TN-C-S <1ns PIV280 SPC 1.1 SPC 3.1 DS 150DS PIV280 -DS 150DS 100kA 160KA 3*100kA 3*160KA (8/20us) (8/20us) (8/20us) (8/20us) 36000J/Ω 100KJ/Ω 3*36000J/Ω 3*100KJ/Ω 50kA 80KA 3*50kA 3*80KA (8/20us) (8/20us) (8/20us) (8/20us) B80 B100 B80 B100 120kA 150KA 120kA 150KA (8/20us) (8/20us) (8/20us) (8/20us) 1600kJ/Ω 2500KJ/ Ω 1600kJ/Ω 2500KJ/ Ω PIV 12.5-275 DS or PIV 230 DS (PIV 280-DS) 40kA or 100kA(8/20us) 3*40kA or 3*100KA (8/20us) Yes <800V Optional LED Voltage free relay contact min 50dB @ 5 Mhz min 40 dB @ 0.1 ~ 30 MHz 1000 times less di/dt and dv/dt IP65 -25°C ~ +85°C, 0-95% Weather proof ANSI/IEEE C62.41-1991 Cat A, Cat B, Cat C ANSI/IEEE C62.41.2 Scenario II, Exposure 3, 100kA, 8/20uS