Unit 29 Three-Phase Transformers Construction • A three-phase transformer is constructed by winding three single-phase transformers on a single core. • Three-phase transformers are connected in either wye or delta configurations. Unit 29 Three-Phase Transformers Three-phase transformer construction. Unit 29 Three-Phase Transformers Three-phase transformer (Courtesy of Waukesha Electric Systems). Unit 29 Three-Phase Transformers Transformer Bank • Two or three single-phase transformers can be connected together to deliver three-phase power. This is referred to as a transformer bank. • This allows greater maintenance and replacement options. Unit 29 Three-Phase Transformers Primary and Secondary Connections • The primary (input) side of a three-phase transformer can be connected in a wye or delta configuration. • The secondary (output) side of a threephase transformer can also be connected in a wye or delta configuration. Unit 29 Three-Phase Transformers Primary and Secondary Connections This allows four basic connection patterns: • Wye-Wye • Delta-Delta • Wye-Delta • Delta-Wye Unit 29 Three-Phase Transformers Wye-delta three-phase connection schematic. Unit 29 Three-Phase Transformers Delta-wye three-phase connection schematic. Unit 29 Three-Phase Transformers Winding identification. Unit 29 Three-Phase Transformers Transformer bank without connections. Unit 29 Three-Phase Transformers Transformer bank connected wye-delta. Unit 29 Three-Phase Transformers One-line Diagram One-line diagrams are simplified schematics used to show the main power distribution systems for commercial or industrial settings. Unit 29 Three-Phase Transformers Industrial one-line power distribution schematic. Unit 29 Three-Phase Transformers Safety test prior to closing the delta connection. Unit 29 Three-Phase Transformers Example #1 schematic with all values. Unit 29 Three-Phase Transformers Example #2 schematic with all values. Unit 29 Three-Phase Transformers Harmonics Harmonics are voltages or currents that operate at frequencies that are multiples of the fundamental power frequency. The fundamental frequency is usually 50 or 60 Hz. Unit 29 Three-Phase Transformers Sine wave distortion caused by harmonics. Unit 29 Three-Phase Transformers Pulse Mode Power Supplies Many power supplies for computers and office machines use pulse-width modulation. This can contribute to harmonic and power quality problems. Unit 29 Three-Phase Transformers Pulse-width modulation schematic. Unit 29 Three-Phase Transformers Harmonic Reduction 1. Reduce the neutral current in threephase systems by balancing the currents in the phase legs. 2. Reduce triplen harmonics on the neutral by adding filters. Unit 29 Three-Phase Transformers Harmonic Reduction 3. Avoid shared neutrals and provide a separate neutral for each phase conductor. 4. Install larger neutrals, especially on multiphase circuits using a common neutral. Unit 29 Three-Phase Transformers Harmonic Reduction 5. Derate the load capacity of transformers and consider buying harmonic-rated transformers.