SLIC Housing & Lens Assemblies Product Data Sheet 100/1 Issue 2 JY X Select the panel hole size, then the lens/bezel from the appropriate table. Units can either be ordered as Complete Assemblies or separate parts using the Codes given. Lens Colour Codes 19mm Panel Hole fixing Options Standards Product Code Make-up 30 Lens Dia mm BKY(Colour) Lens + Bezel (if welded) Bezel (if separate) MP Housing Panel Front 1 Panel locking nut 2 Lens 17 MA(Colour) MC(Colour) BM BM BKY 19 1 4 MP Body Only 4 Lens Lens Lens Lens MKY Colour Code MY Colour Code MJ Colour Code MXA Colour Code MXC Colour Code IP65 IP64 IP64 IP65 IP65 Protection Lens Material 17.5 BJ(Colour) 3 2 Indicator locking ring 3 O Ring 17 x 1 Complete Assembly 22.3 30 BY(Colour) A = Amber B = Blue G = Green R = Red T = Clear (Transparent) W = White (Opal) Polycarbonate Bezel Material Black plastic Polycarbonate Polycarbonate Polystyrene Polystyrene Chromed brass Chromed brass Chromed brass Chromed brass Housing Black moulded glass reinforced nylon Protection to IP65 Standard DIN Keyway Available for all assemblies with M KEYWAY WASHER. (Specify ''DIN Keyed'') IP65 SEALING WASHER Standard Not available BY Standard behind lens BJ Legend Plates Blank or engraved as required. Anodised aluminium, self-adhesive (Data Sheet 214) BYLP BYLP BJLP BJLP BJLP 30 22.3 21.5 23.5 BJ(Colour) FA(Colour) FB(Colour) ADMF BFA BFB 22.5mm Panel Hole fixing Product Code Make-up 30 Lens Dia mm BKY(Colour) Lens + Bezel (if welded) Bezel (if separate) 1 O Ring 19x2.5 Housing 1 Panel locking nut 2 Indicator locking ring 3 MP Body Only Standards 1 FP MP FXP 4 Panel Front 5 1 19 2 3 3 5 BF Adaptor Protection Lens Material MC + BM 1 19 20.5 2 4 FP Body Only Complete Assembly Options BY(Colour) MA + BM FKY Lens Colour Code IP65 Polycarbonate Bezel Material Black plastic FY Lens Colour Code FJ Lens Colour Code IP64 IP64 FXA Lens Colour Code IP64 FXB Lens Colour Code IP64 Polycarbonate Polycarbonate Polystyrene Polystyrene Chromed brass Chromed brass Chromed brass Chromed brass Housing Black moulded glass reinforced nylon Protection to IP65 Standard DIN Keyway Available for all assemblies with F KEYWAY WASHER. (Specify ''DIN Keyed'') IP65 SEALING WASHER + chromed brass adaptor Not available behind lens O RING 19x2.5 housing -panel O RING 19x2.5 behind lens Use BEZEL FH PT P Legend Plates Blank or engraved as required. Anodised aluminium, self-adhesive (Data Sheet 214) BYLP BYLP FA + BFA BYLP FHLP FHLP FB + BFB 100 Housings/lenses for Tranilamp SLIC Indicator Lamp Body Units. Product Code Guide & Dimensions SLIC Product Data Sheet 100/2 Issue 1 Indicators + housing assembly = TU 24 110 240 440 24 110 TEU 240 440 24 240 MTU 110 DTU LU IRU 110 NU 240 440 110V 240V NB2R 110V 240V single diode led lamps 4diode led clusters 7 diode led clusters 26 13 26 15 26 4.5AC LED M1 B 24AC 24DC A 4.5AC G 24AC R 24DC 4.5AC 24AC W 110AC 4.5DC 24DC 4.5AC 24AC LED4 B 110AC 4.5DC 24DC 4.5AC A 24AC G 110AC R 4.5DC 24DC 4.5AC 24AC W 110AC 4.5DC 24DC 4.5AC 24AC LED7 B 110AC 4.5DC 24DC 4.5AC A 24AC G 110AC R 4.5DC 24DC C C C Product Code: Option LED Colour Code LR1 C C C C C C C TU DTU MTU LU LU Lamp Remover Suitable to remove MBC filament, led cluster and neon lamps from all lamp bodies. A = Amber R = Red B = Blue W = White G = Green Standard lamp included free of charge C Customised. Prices from Technical Sales OK at extra price Lamp Matching Key C 4.5AC W 24AC 24DC FIL 6V 12V 24V 28V 50V 60V 130V A 4.5 LED G (AC M1F R & B DC) W MBC TU DTU MTU Product Code 1) MKYA - MTU/240/LED7A 4.5AC MBC Examples: 2) FXAB - TU/110 lamps ( LEDs, filament and neons) Alternatively, select optional LED or non-standard Filament Lamps NG2R 110V 240V MBC filament MBC + 6V filament lamp fitted as standard to TU, TEU & MTU free of charge. DO NOT SPECIFY ANY LAMP, IF THIS IS REQUIRED. Select optional lamps neon/ fluorescent c/w internal R NW2R no internal R LED and filament lamps neon/ fluorescent NG2 NB2 NW2 MBC Select the appropriate lamp 49 15 Select optional lamps Select lamp by colour 22.5 22.5 22.5 22.5 22.5 MBC indicator lamp bodies transformer lamp ac only Standard lamps: 6V filament 4.5VAC LED TU with earthed secondary multi-test lamp ac only 19 99 100 119 17 49 66.5 26 MBC complete lens/housing assembly MKY MY MJ A B G R T W Standard lamps: 6V filament 4.5VAC LED dc multi-test lamp dc only Lamps: filament up to 60V LED 4.5VDC or 24DC direct low voltage lamp ac/dc Lamps: filament up to 130V LED any volts AC/ DC dc lamp dc only Contact Technical Sales for permissible supply & lamp voltages neon lamp ac only Lamps: neon/flouorescents without built-in R 19 22 MBC bezel (if not in lens assembly) MP MXA MXC A B G R T W Select bodies and lamps FKY FY FJ FXA FXB 19 24 MBC Select the panel hole lens type and follow the relevant bars noting product codes. Lenses, bezels and housings may be ordered separately or as a completed assembly. Choose the indicator body required and finally the lamp. + BM BM A = Amber G = Green T = Clear B = Blue R = Red W = White len co s lou r SLIC Product Selection Guide BKY BY BJ A B G R T W Lens Codes FP MP + ADMF FXP c 19 30 31.5 26 28.5 28.5 15 MBC lens/ lens assembly 19mm panel hole lens: 30mm polycarbonate bezel: 30mm black plastic lens: 30mm polycarbonate bezel: 31.5mm chromed brass lens: 22.3mm polycarbonate MA MC BKY BY A B G R T W BFA BFB b 19 23 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 30 31.5 23.5 23 14 30 22.3 21.5 23.5 p bezel: 24mm chromed brass lens: 17.5mm polystyrene bezel: 22.5mm chromed brass lens: 17.5mm polystyrene bezel: 22.5mm chromed brass 22.5mm panel hole lens: 30mm polycarbonate bezel: 30mm black plastic lens: 30mm polycarbonate BJ FA FB Panel a 10 30 MBC MBC bezel: 31.5mm chromed brass lens: 22.3mm polycarbonate bezel: 24mm chromed brass lens: 21.5mm polystyrene bezel: 28.5mm chromed brass lens: 23.5mm polystyrene bezel: 28.5mm chromed brass d e 10 10 14 30 22.3 17.5 17 11 10 30 typ e neon lamps typ e co lou vo r lts ca p MBC lts p ca blue ca MBC vo orange typ e green green orange blue TU TEU MTU DTU LU IRU NU typ e a mm b mm c mm d mm e mm Weight g Body typ e su vo pply lts Contact Technical Sales MKY MY MJ MXA MXB FKY FY FJ FXA FXB len co s lou r Critical Dimensions b+c= front of panel to back of indicator Housing ordering lens/housing separately ordering lens/housing separately typ e