PWR Secondary Side Chemistry Consulting Optimum chemical conditions of the secondary side to prevent and reduce detrimental phenomena High availability and reliable operation of nuclear power plant are the searched goals by the operator. Water chemistry plays an important role on the performance and on the preservation of the secondary side components against corrosion degradation phenomena. The most effective way of counteracting all degradation problems and thus of improving the SG performance is to maintain clean conditions. The material and design concept of the plant let the operator the degree of freedom of chemistry to adopt the suitable treatment to preserve the system clean. AREVA’s recommendations lead to the best suitable operational conditions which facilitate the reduction of: • corrosion phenomena as FAC • ingress of corrosion product inventory and impurities into the steam generator • time of response against abnormal situations AREVA consulting team supports the plants to achieve the optimal chemistry strategy by: • Evaluation of the chemical parameters and comparison with other plants • Assessment of data plausibility and consistency • Monitoring the of steam generator conditions and evaluating the steam generator situation • Setting concepts which reduce the impurity and corrosion product levels in the system during annual outages • Supporting the plant to re-establish the clean condition • Plant staff training in trouble solving for daily operation • Revision of chemistry guidelines The pro-active maintenance measures can be complemented with on site support in order to gain time by solving technical problems during start-up or operation. Water Chemistry Data Inspection Results Thermal Performance (e.g. iron ingress, hide-out) (e.g. visual, sludge mapping) (e.g. heat transfer) Steam Generator Assessment No measures required Measures required Steam Generator Cleaning Preventive Chemical Cleaning Curative Chemical Cleaning Mechanical Cleaning (e.g. Tube sheet and/or inner bundle lancing, upper bundle flushing) Improvement of Water Chemistry Continuous Steam Generator Surveillance AREVA’s integrated concept for steam generator assessment and surveillance PWR Secondary Side Chemistry Consulting Overview of latest AREVA projects • Chemistry support for steam generator replacement of a plant in Westinghouse design • Frequent on-site chemistry support for minimization of corrosion product generation and transport • Regular steam generator cleanliness assessments for German and International PWRs • (On-site) Plant support during conversion of 2 PWRs to H-AVT chemistry treatment • On-site training for water chemistry staff • R & D project on water chemistry treatment with focus on lay-up • Contribution to IAEA TecDoc 1668, “Assessment and Management of Ageing of Major Nuclear Power Plant Components Important to Safety: Steam Generators” Further AREVA products • Database of qualified products for maintenance work and during outage • Diagnosis Monitoring System • PWR Primary Side Chemistry Consulting • BWR Chemistry Consulting • PHWR Chemistry Consulting IMPURITY CONCENTRATION IN CREVICE TS-DEPOSITS Spent Solvent Spent Solvent Fresh Solvent Impurity enrichment in the steam generator Flow Assisted Corrosion (FAC) Your Benefits at a Glance • AREVA international experience covers plant designs of various OEMs • Knowledge of manifold chemistry treatments and chemistry guidelines • State-of-the-art chemistry measures applied at AREVA’s EPRTM • Tailored plant specific studies in close cooperation with operators fitting your needs and requirements AREVA NP GmbH Your contact: NPP-Chemistry@areva.com Editor and Copyright 2012: AREVA NP GmbH – Paul-Gossen-Straße 100 – 91052 Erlangen, Germany. It is forbidden to reproduce the present publication in its entirety or partially in whatever form without prior written consent. Legal action may be taken against any infringer and/or any person breaching the aforementioned conditions. Subject to change and error without notice. Illustrations may differ from the original. The statements and information contained in this brochure are for advertising purpose only and do not constitute an offer of contract. They shall neither be construed as a guarantee of quality or durability, nor as warranties of merchantability or fitness for a particular purpose. These statements, even if they are future-oriented, are based on information that was available to us at the date of publication. Type, quantity and characteristics of goods and services G-190-V1-12-ENGPB are subject to formal individual formal contracts.