to a Sample report.

advertisement

Report ID: JD123Anystreet1225141

ArcStar Inspections

25 Knobhill Rd., North Conway, NH 03860 603-733-9192

Home Inspection Report

Property Address: 123 Any Street, Anytown, New Hampshire

Client: John Doe

Date: December 25th, 2015

Inspector: Richard Chavez, CPI - License No.NH284

General Info

PLEASE NOTE:

This report is the exclusive property of ArcStar Inspections and the client whose name appears herewith, and its use by any unauthorized persons is strictly prohibited.

The observations and opinions expressed within this report are those of ArcStar Inspections

Inspection and supersede any alleged verbal comments. We inspect all of the systems, components, and conditions described in accordance with the standards of National Association of

Certified Home Inspectors (iNACHI) along with the Standards of Practice set forth by the State of

New Hampshire and those that we do not inspect are clearly disclaimed in the contract and/or in the aforementioned standards. However, some components that are inspected and found to be functional may not necessarily appear in the report, simply because we do not wish to waste our client's time by having them read an unnecessarily lengthy report about components that do not need to be serviced.

In accordance with the terms of the contract, the service recommendations that we make in this report should be completed well before the close of escrow by licensed specialists, who may well identify additional defects or recommend some upgrades that could affect your evaluation of the property.

Report ID : JD123Anystreet1225141

Date : December 25th, 2015

Time : 9:00am

Property : 123 Any street, Anytown, New Hampshire, Maine

Customer : John Doe

Style of home : 2bedroom 2.5 bath

Age of Home : b2004 - 10 years

Client is Present with buyer's agent and listing agent

Weather : Sunny Partly Cloudy

Temp : 70 degrees

Interpreting the Inspection Results

Each item or area inspected will be marked with a finding, which represents the inspection result for that item. The followin g descriptions represent an explanation for each of the inspection findings.

Inspected - Appears Functional =

The item, component, or unit was visually observed, and if no other comments were made, then the item appeared to be functioning as intended, allowing for normal wear and tear.

Repair or Replacement Recommended =

The item, component or unit was visually observed, and is not functioning as intended or needs further inspection by a qualified specialist. Items, components or units that can be repaired to satisfactory condition may not need replacement.

General Maintenance Item =

These are repairs that, in the opinion of the inspector, are regular maintenance items typical for all homes. Repair to these items is not urgent, but should be performed in the near future.

Service Needed =

The item, component, or unit is functioning, but a service check-up is recommended to optimize performance.

Limited Inspection =

The item, component, or unit was not fully inspected, and some form of limitation is preventing a complete inspection of the item/area. The report will state a reason for the limited inspecting of the item.

Energy Savings-Efficiency Recommendation =

An energy related improvement item is noted with recommendations on the appropriate upgrade or repair.

Not Inspected =

The item, component, or unit was not inspected, and no representations of whether or not it was functioning as intended are made. The report will state a reason for not inspecting the item.

Not Present =

The item, component or unit is not in this home or building.

Table of Contents

Cover Page

Intro Page

Table of Contents

1 Exterior - Grounds

2 Foundation - Basement

3 Roofing - Attic - Ventilation

4

5

Plumbing

Electrical System

6 Heating System

7 Interior

8 Built-In Appliances

9 Garage

10 Septic System

Summary

Back Page

Sections

!

The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation.

This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the home. As used in the

Summary, "Repair or Replace" refers to a system or component that is not functioning as intended and is in need of Repair or Replacement; This Summary is not the entire report. Regardless, in recommending service we have fulfilled our contractual obligation as generalists, and therefore disclaim any further responsibility. However, service is essential, because a specialist could identify further defects or recommend some upgrades that could affect your evaluation of the property. The complete report may include additional information of concern to the person who ordered this inspection.

This report is the exclusive property of ArcStar Inspections LLC. and the client whose name appears herewith, and its use by any unauthorized persons is prohibited.

1. Exterior - Grounds

We evaluate the following exterior features: driveways, walkways, fences, gates, handrails, guardrails, yard walls, carports, patio covers, decks, building walls, fascia and trim, balconies, doors, windows, lights, and outlets. However, we do not evaluate any detached structures, such as storage sheds and stables, and we do not water test or evaluate subterranean drainage systems or any mechanical or remotely controlled components, such as driveway gates. Also, we do not evaluate landscape components, such as trees, shrubs, fountains, ponds, statuary, pottery, fire pits, patio fans, heat lamps, and decorative or low-voltage lighting. In addition, we do not comment on coatings or cosmetic deficiencies and the wear and tear associated with the passage of time, which would be apparent to the average person. However, cracks in hard surfaces can imply the presence of expansive soils that can result in continuous movement, but this could only be confirmed by a geological evaluation of the soil.

Styles & Materials:

Siding Material: Wooden Wood Clapboard

Exterior Entry Doors: Metal

Deck/Porch/Balcony: Wooden/Composite

Driveway / Walkway: Asphalt

Inspection Items:

1.0WALL COVERING, FLASHING AND TRIM

Comments: Inspected - General Maintenance Items

Several areas of siding around the home are slightly loose but are not firmly fastened to the wall. An overall review and fastening of all loose siding material is recommended.

Several pieces of siding located between windows of the rear porch were loose or have already fallen out. Repair and or replacement is recommended.

1.1EAVES, SOFFITS AND FASCIAS

Comments: Inspected - Appears Functional

A wooden member at the peak of the soffit at the rear of the home is loose and falling out. This can lead to pest and insect intrusion as well as damage from weather elements. Repair is recommended.

1.2DOORS (Exterior)

Comments: Inspected - Appears Functional

1.3WINDOWS (Exterior)

Comments: Inspected - Appears Functional

1.4DRIVEWAYS, WALKWAYS, AND PATIO SLAB

Comments: Inspected - Appears Functional

1.5GRADING AND DRAINAGE

Comments: Inspected - Appears Functional

1.6 DECKS

Comments: Inspected - Repair or Replacement Recommended

The front and rear exterior stairwells are damaged due to weather elements and age. Damage is located on the stairwell stringers and has left many of the treads poorly fastened. Also some stringers have deteriorated completely and have failed. Some treads are loose making some stairs a trip hazard and may cause severe bodily harm. Repair or replacement by a qualified contractor is recommended.

2. Foundation - Basement - Crawlspace

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed.

Styles & Materials

Foundation: Concrete Wall

Basement / Crawlspace:

Method used to observe basement: Entered and inspected

Floor Structure: Concrete

Wall Structure: Concrete/wooden framed

Basement/Crawlspace Insulation: Fiberglass batting

Inspection Items

2.0FOUNDATIONS, BASEMENTS AND CRAWLSPACES

Comments: Inspected - Appears Functional

2.1WALLS

Comments: Inspected - Appears Functional

2.2FLOORS

Comments: Inspected - Appears Functional

3. Roofing - Attic - Ventilation

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed.

Styles & Materials

Roof Covering: Asphalt Shingle

Viewed roof covering from: Eave with ladder and binoculars

Chimney (exterior): Not Present

Gutter & Downspout Material: Not Present

Attic info: No Attic/No Access

Method used to observe attic: None

Roof Structure: Vaulted

Attic Insulation: Unknown

Ventilation: Ridge Vent / Soffit Vents

Inspection Items:

(continued)

3.0ROOF COVERINGS

Comments: Roof Inspect- General Maintenance Items

A section of roofing is improperly installed. At the rear of the home at the roof connection to the porch roof a shingle is raised and exposing its underside and other components to water runoff and damage.

The proper cut and proper flashing should be installed to divert water away from this area. A review and repair by a qualified roofing contractor is recommended.

The roofing on the right side of a dormer on the front of the home is covered in moss and fungus. Moss typically eats away at roofing materials and causing damage. This leaves the area vulnerable to further damage by water and other weather elements. The removal of moss and fungus and the repair of any damaged shingles is recommended. Roofing repairs should be performed by a qualified roofing contractor.

4. Plumbing System

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed.

Styles & Materials

Water Supply (into home): Polyethylene

Water Distribution (inside home): Copper

Drain Waste & Vent Material: ABS/PVC

Water Heater Power Source: Propane

Water Heater Capacity: 40 gallon

Manufacturer: Bradford White

Approximate Age: unknown - possibly original

Washer Drain Size 1.5"

Inspection Items

4.0MAIN WATER SHUT-OFF DEVICE LOCATION

The main water shut off is located in the basement utility room This is for your information.

4.1WATER SUPPLY AND DISTRIBUTION SYSTEMS

Comments: Inspected - Appears Functional

4.2FIXTURES & FAUCETS

Comments: Inspected - Appears Functional

4.3TOILETS & BIDETS

Comments: Inspected - Appears Functional

4.4DRAIN, WASTE AND VENT SYSTEMS

Comments: Inspected - General Maintenance Item

A water leak is present beneath the kitchen sink when in operation. Water staining and damage to the cabinet is visible. Repair is recommended.

4.5HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS

Comments: Inspected - Appears Functional

4.6MAIN FUEL SHUT OFF (Describe Location)

Comments: Inspected - Appears Functional

Main shut off on Feed line off of hub manifold in Basement Utility Room

5. Electrical System

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed.

Styles & Materials

Electrical Service Conductors: Overhead

Electrical Service Voltage Rating: 240v

Service Amperage & Panel capacity: 200a

Main Disconnect Location: in Panel

Panel Type: Breaker

Electric Panel Manufacturer: Square D

Branch wire 15 and 20 AMP: Romex

Wiring Methods: Standard

Smoke Detectors: Present Hardwired all passed testing

Carbon Monoxide Detectors: Not Present

Inspection Items

5.0SERVICE ENTRANCE CONDUCTORS

Comments: Inspected - Appears Functional

5.1LOCATION OF MAIN AND DISTRIBUTION PANELS

Comments: Inspected - Appears Functional

Main Panel is located in the garage.

5.2MAIN DISCONNECT DEVICE

Comments: Inspected - Appears Functional

5.3MAIN & DISTRIBUTION PANELS, SERVICE AND GROUNDING EQUIPMENT

Comments: Inspected - Repair or Replacement Recommended

An electrical panel breaker knockout is missing and empty. This is an electrical and shock hazard.

Repair or replacement with the proper equipment is recommended. It is also recommended that repairs to the electrical system be performed by a qualified electrical contractor.

5.4FIXTURES, SWITCHES & CONNECTED DEVICES

Comments : Inspected - Appears Functional

Note: Light bulbs were not present in the main entrance exterior lighting fixtures. Repair is recommended.

5.5RECEPTACLE OPERATION (POLARITY AND GROUNDING)

Comments: Inspected – Appears Functional

5.6OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)

Comments: Inspected – Appears Functional

6. Heating System

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed.

Styles & Materials

Primary Heating System: Forced Hot Air

Energy Source: Propane

Number of Heat Systems (excluding wood): 1

Approximate Age: Unknown - Possibly original

Filter Type: Media

Filter Size: 16x25x1

Operable Fireplaces: 1 Propane

Inspection Items

6.0HEATING EQUIPMENT

Comments: Inspected - Appears Functional

The gas propane furnace was fully tested and inspected, and is operating properly at this time. The unit appears to be in good condition. No actions are needed. An annual service check up and cleaning is recommended, to keep the unit is good working condition.

6.1THERMOSTAT

Comments: Inspected - Appears Functional

6.2AUTOMATIC SAFETY CONTROLS

Comments: Inspected - Appears Functional

6.3 DISTRIBUTION SYSTEMS (including fans, ducts, air filters, registers)

Comments: Inspected - Appears Functional

6.4CHIMNEYS, FLUES AND VENTS (for heating system)

Comments: Inspected - Appears Functional

7. Interior

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed

Styles & Materials

Ceiling Materials: Drywall

Wall Material: Drywall

Major Floor Covering(s): Wooden/Carpet

Interior Doors: Wooden

Window Types: Vinyl

Cabinetry: Wooden

Dryer Vent: To Exterior

Dryer Power Source: Electric

Inspection Items:

7.0CEILINGS

Comments: Inspected – Appears Functional

7.1WALLS

Comments: Inspected - Appears Functional

7.2FLOORS

Comments: Inspected - Appears Functional

7.3DOORS (REPRESENTATIVE NUMBER)

Comments: Inspected - Appears Functional

7.4WINDOWS (REPRESENTATIVE NUMBER)

Comments: Inspected - General Maintenance Items

A few windows were found to be missing screens. Screens are essential in keeping out insects, pest and certain types of weather elements. Replacement is recommended. A bank of screens were found in the basement and screens that match those missing may be present and stored in this location.

7.5COUNTERS AND CABINETS

Comments: Inspected - Appears Functional

7.6BATHROOM TUB/SHOWER SURROUND

Comments: Inspected - Appears Functional

7.7VENTING SYSTEMS (Kitchens, baths and laundry)

Comments: Inspected - Appears Functional

8. Built-In Appliances

The following components were observed and inspected. A description of the area materials and styles is included, and any observations and/or recommendations are listed.

Styles & Materials

Dishwasher: Present tested and passed

Exhaust/Range hood/Microwave: Present tested and passed

Range/Oven: Present tested and passed

Refrigerator: Present tested and passed

Inspection Items:

8.0DISHWASHER

Comments: Inspected - Appears Functional

8.1RANGES/OVENS/COOKTOPS

Comments: Inspected - Appears Functional

8.2RANGE HOOD/MICROWAVE

Comments: Inspected - Appears Functional

9. Garage

Garage was inspected by home inspector. All garage door safety features were tested and were proven to be in correct working order and in compliance with safety regulations. One Automatic door tested.

Comments: Inspected – Appears Functional

10. Onsite Waste Disposal System

Comments: Inspected

– Appears Functional

The inspection of private onsite sewage (waste disposal) systems is not part of a standard home inspection. When provided as an ancillary service, the inspection of private sewage systems is limited to readily visible and accessible elements and system function as listed herein. Evaluation of the system is based primarily on a water flow test and conditions visually apparent at the ground surfaces and through holes dug in ground. Pre-inspection vacancy, limited use of the system, overgrowth at the drainage field, frozen ground conditions, soil conditions, and depth of system in ground and snow cover can severely restrict the ability to assess system operation. Detailed information on the private sewage system's condition, usage issues, prior problems, repairs, and maintenance needs is should and or be obtained from the homeowner and service company. Obtaining this documentation is the responsibility of the client. The client acknowledges that the inspection is of the condition of the septic system at the time of inspection and should not be construed to be an indication of the longevity of the septic system. The inspection is not and does not include a guarantee or warrantee of any kind. The future use that the system receives will have a direct bearing on how long the system will last. Proper use and maintenance will be essential to maximize the systems future potential longevity.

WASTE DISPOSAL AREA / LEACH FIELD

DESCRIPTION:

APPROXIMATE SYSTEM AGE: unknown - Possibly original (2004)

DESIGN LIFE:

30 to 40 years

SEPTIC TANK:

Approximate capacity 2000 gallons - Concrete in ground

LAST REPORTED PUMPING DATE:

Not determined

NUMBER OF PEOPLE USING SYSTEM

LAST YEAR:

2-4 people

NUMBER OF BEDROOMS:

2-3 bedrooms

DRINKING WATER SUPPLY:

Public

NUMBER OF PEOPLE MOVING INTO

HOME: 2-4

SPECIAL LIMITATIONS:

None observed

EVIDENCE OF SYSTEM MALFUNCTIONING:

None observed

PRIVATE SEWAGE SYSTEM PLANS:

Site plan provided by listing agent

SCUM LAYER:

Less than <1"

SLUDGE LAYER:

Less than < 1"

P.1 Treatment tank inlet observation portal

P.2 Treatment tank outlet observation portal

P.3 Treatment tank outlet filter

P. 4 and P.5 Distribution Box and Absorption Field Observation Well

P.6Absorption Field

9.1Waste Treatment System

Based on the preliminary information you provided and the field inspection, the inspector found the onsite wastewater treatment system to be in a satisfactory condition on the date of the inspection.

Satisfactory

A water flow test was performed. Water was run at maximum pressure in the second floor bathroom bath tub for 50 minutes in order to simulate heavy daily water flow. Effluent was observed entering and exiting the treatment tank at approximately the same rate. Water levels did not rise within the tank during flow test. Absorption field drained at an appropriate rate. All components were in good working condition at the time of inspection.

Recommendation: Keep absorption field clear cut and free of long growing grass and tree samplings.

Summary

Date: December 25th, 2015

Time: 9:00am

Report ID: JD123Anytown1225141

Property: 123 Any Street, Anytown, New Hampshire, Maine

Customer: John Doe

Inspector: Richard Chavez, CPI - License# 284

The following items or discoveries represent a summary of the inspection items marked Repair-Replacement

Recommended or General Maintenance Item , indicating that these systems or components; (a) do not function as intended or (b) adversely affect the habitability of the dwelling or (c) appear to warrant further investigation by a specialist or

(d) require subsequent observation.

Bear in mind that all homes need repairs of one type or another, even if only minor.

Generally, older homes need more repairs. All safety concerns should be reviewed and repaired prior to occupancy. While every effort is made to identify existing and potential problems at the time of the inspection, it is not possible for a home inspector to foresee all problems that might arise in the future. We recommend that a budget is established for unforeseen repairs and maintenance.

Several areas of siding around the home are slightly loose but are not firmly fastened to the wall.

An overall review and fastening of all loose siding material is recommended.

Several pieces of siding located between windows of the rear porch were loose or have already fallen out. Repair and or replacement is recommended.

A wooden member at the peak of the soffit at the rear of the home is loose and falling out. This can lead to pest and insect intrusion as well as damage from weather elements. Repair is recommended

The front and rear exterior stairwells are damaged due to weather elements and age. Damage is located on the stairwell stringers and has left many of the treads poorly fastened. Also some stringers have deteriorated completely and have failed. Some treads are loose making some stairs a trip hazard and may cause severe bodily harm. Repair or replacement by a qualified contractor is recommended.

A section of roofing is improperly installed. At the rear of the home at the roof connection to the porch roof a shingle is raised and exposing its underside and other components to water runoff and damage. The proper cut and proper flashing should be installed to divert water away from this area. A review and repair by a qualified roofing contractor is recommended.

The roofing on the right side of a dormer on the front of the home is covered in moss and fungus. Moss typically eats away at roofing materials and causing damage. This leaves the area vulnerable to further damage by water and other weather elements. The removal of moss and fungus and the repair of any damaged shingles is recommended. Roofing repairs should be performed by a qualified roofing contractor.

A water leak is present beneath the kitchen sink when in operation. Water staining and damage to the cabinet is visible. Repair is recommended.

An electrical panel breaker knockout is missing and empty. This is an electrical and shock hazard. Repair or replacement with the proper equipment is recommended. It is also recommended that repairs to the electrical system be performed by a qualified electrical contractor.

A few windows were found to be missing screens. Screens are essential in keeping out insects, pest and certain types of weather elements. Replacement is recommended. A bank of screens were found in the basement and screens that match those missing may be present and stored in this location.

END OF SUMMARY

Inspector: Richard Chavez Jr. #284

Thank you for utilizing our services

– we appreciate your confidence in ArcStar Inspections.

Should any questions about this report arise, please do not hesitate to contact us for assistance or an explanation. 603-733-9192 ArcStarInspections@gmail.com