30-150 Bryant Electric, Circuit Protective Devices Bridgeport, Connecticut 06606 Page 1 Safety Switches Motor Circuit Switches w .E lec tri ca lP ar tM an ua ls August ?R, 1985 New Information For standard terms of sale, refer to Selling Policy 30-000 Maileu to: E, D, C/30- 1 00A, EFML-E0 1 , E02, E0 3, E0 4 ww .c om 8 Catalog Westinghouse Electric Corporation .c om Catalog 30-150 Page2 Heavy Duty Safety Switches Features Star mounting holes S teel cross arm controls contacts; provides positive Diamond pointed jaws prevent burning and pitting f current-carrying surfaces Door interlock prevents cover from being opened hen switch is energized Insulated shield prevents accidental contact with t----line terminals Blades are visible in open or closed position Front-operated handle ith high-visibility red vinyl sleeve lec tri ca lP ar tM an blade alignment Door latch securely holds door closed; permits padlocking in closed position ua ls De-ion arc chute interrupts and cools arcs for longer switch life at top and bottom for easy installation. mple knockouts .E on all four sides and at rear of enclosure Easily-accessible S hort circuit ww w withstand ratings fuse clips are reinforced for lower operating temperatures and long-life performance Ample wiring room speeds installation Pressure-type aluminum line and load terminals can be used with copper or aluminum wire Line and load bases constructed of high -impact phenolic August, 1 985 0 f) .c om Catalog 30-150 Page 3 Heavy Duty Safety Switches Features DUAL PURPOSE INTER· LOCK: Prevents switch from being thrown ON with cover open; prevents cover from being opened unless switch is OFF. Authorized personnel can bypass both conditions by RATING iDENTIFICATIC,''i Embossed nameplate ua ls enhances appearance and permanently identifies Westinghouse name, catalog numbers, volts, ampere and horsepower ratings. No need to open inserting screwdriver into door to obtain data. interlock defeater (cover slot located above handle). an TEASEPROOF SW ITCH resistance to rust. Scratches cannot spread ar even though they extend through to the bare metal. tM DURABLE FINISH: Entire enclosure is bonderized inside and out and coated with baked on enamel for maximum durability and lP FRONT OPERATED HANDLE: An integral part of switch mechanism, the easily accessible handle permanently controls con- tri ca tacts, permits close ganging, does not disconnect when door is opened. Red vinyl sleeve provides high visibility; indicates handle position (down for OFF; up for ON). ww w .E lec PADLOCKING: Operating handle can be padlocked in OFF position by three padlocks with 3/8" hasps. Prevents closing of contacts - an essential requirement for heavy-duty ''\< August,1985 industrial applications. Handle can be padlocked in ON position by drilling MECHANISM: Over-center design with positive drive spring action maximizes strength of quick-make, quick-break switch mechanism. Prevents contact teasing. Handle operates independently of cam and crossbar, allowing cover to be opened or closed in the unlikely event of drive spring breakage. STEEL CROSS ARM AND YOKES: Steel yokes in an impact-resistant glass polyester insulating block firmly engage steel crossarm that drives the moving blades and provides posi· tive blade alignment. DIAMOND-POINTED BREAK-JAWS: Moving contacts extend beyond the break-jaws, permitting the breaking arc to travel along the outside non current-carrying edges of jaws and blades. Prevents burning and pitting of current-carrying surfaces. hole in handle at position marked "X". DE-ION ARC CHUTE REMOVABLE I!\JT PARTS: All interior parts are easily removable from the front if replacement is necessary. Prevents arc damage by interrupting and cooling hot arcs. Molded material of chute is carbonizing and track resistant. Prolongs switch life; allows maximum horsepower ratings permitted by UL. .c om Catalog 30-150 Page 4 PF-311-N ua ls General Duty Safety Switches Plug Fuse, Fusible and Non-Fusible RGFN-321-N !I 2-WireSN ww switches are Underwriters' Laboratories listed and suitable for use as Service Entrance Equipment when neutral is provided or grounding kit is employed. CAT. NO. - --- 22 ar 2-"Pc;l� APPROX. STD. WT. LBS. PKG. PF-211-N 30 vv�n: l\!Dt�t: �.,; 3-WireSN CAT. NO. PF-311-N 26 __ HORSEPOWER . .•.•. .••• . !!�!!!'!§ � _ . 240V F'_I( iAK -�ID..:-�M�x:��:ro: APPRO X. :STD. wT. L Bs. G: . . .. 120V 10 RPF-211-N 17 5 2 10 RPF-311-N 20 5 2 ---- · FUSIBLE, 24Q_�_9LTS Ac- NEMA 1 AND 3R ENCLOSURES lP NEMA 1 INDOOR POLES AMPS CAT. NO. << , 2-Pole 30 60 � GFN-221 ( Use 3 Wire, ' 2 Pole Solid ca 2-Wire 100 I I 200 400 �--?Q() -------- ' 2-Pole APPRO X. , STD. WT. LBS. :PKG. � <- - ..., "-- --- __ ______ 45 10 60 100 200 400 600 l Below 45 GFN-322-N 15 10 20 GFN-324-N 31 GFN-325-N 140 GFN-326-N 235 �-----------�----·-·······----·· 3-Pole 30 3-Wire !- --·-··-·--···•·· 3-Pole 4-WireSN 1 60 100 200 , I Use 4 Wire, 3Pole Solid Neutral Listings Below GFN-325 145 ��--'---�-"!:326 290 400 - 1 • RGFN-221 32 2 Pole Solid Neutral Listings Be low -"-·----- -------------· -·- GFN-321-N GFN-323-N - NEMA 3R RAINPROOF .use 3 Wire, ) Neutral . 1 Listings 30 3-WireSN lec Meet NEMA Spec. KS1-1975 Meet Federal Spec. WS-865c an AMPS 1-Pole 1- NEMA 3R RA INPROOF NEMA 1 INDOOR tM FUSIBLE SYSTEM S l RGFN-321-N 32 RGFN-322-N 15 3 RGFN-323-N 23 71.2 RGFN-324-N 34 5 11/2 15 3 7112 15 155 50 245 75 100 50 100 RGFN-326-N RGFN-325 160 RGFN-326 300 Use 4 Wire, 3PoleSo lid Neutral Listings Below 45 10 RGFN-421-N 32 5 GFN-422-N 17 1 RGFN-422-N 17 1 100 GFN-423-N 23 RGFN-423-N 26 15 600 l 34 GFN-425-N 145 GFN-426-N 295 l 30 50 GFN-421-N GFN-424-N 15 71/2 15 100 30 200 3 10 25 RGFN-325-N 60 400 UL Listed File E5189 w • .E • GFN-422-N NEMA 1 PLUG FUSE INDOOR, NEMA 3R PLUG FUSE RAINPROOF tri F eatures-Specific:,t; • Embossed metal nameplate permanently identifies cat. no., amps, hp ratings Front-operated handle permits close ganging. Handle is integral part of switching mechanism; provides permanent control of contacts; can be padlocked in OFF or ON position ' Red vinyl cover instantly identifies handle; indicates position Blades visible in open or closed position • Twin reinforced blades provide maximum surface contact • Quick-make, quick-break, tease­ proof switching mechanism ' Diamond-pointed break jaws prolong blade life; keep silver-plated contact area free of pitting and burning • Tin plated current carrying parts provide an excellent bearing surface for moving parts • Easily accessible fuse holders suitable for standard and time delay fuses at maximum UL ratings • Ample knockouts and wiring room • Line and load terminals suitable for copper or aluminum wire • Door latch securely holds door closed; permits padlocking • Door interlock prevents door from opening when switch is energized • Star mounting feet assure easy mounting GFN-321-N 7112 RGFN-424-N 37 25 RGFN-425-N 160 50 RGFN-426-N 305 75 100 NOI\I-F�_S.IBL.S1_4_QVOLTS Ac :- NEMA 1 AND 3R ENCLOSURES 2-Pole 30 2-Wire 60 100 200 400 600 10 Use 1 3Pole Listings Below 3-Pole 30 GUN-321 45 10 3-Wire 60 GUN-322 16 1 rn RGUN-221 32 RGUN-222 15 5 3 10 use 3Pole Listings Below RGUN-321 32 RGUN-322 17 5 712 15 100 GUN-323 18 RGUN-323 21 30 200 GUN-324 32 RGUN-324 36 50 400 GUN-325 135 RGUN-325 150 GUN-326 100 600 290 RGUN-326 300 100 For price information see Bryant Price List BPL 30·125 August, 1 985 .c om Catalog 30-150 Page 5 NEMA 1 PLUG FUSE INDOOR, NEMA 3R PLUG FUSE RAINPROOF General Duty Safety Switches Dimensional Data, Nema 1, Nema 3R PF P lug Fuse S witches, RPF Plug Fuse Switches ua ls 30 1, 2 1 INDOOR NEMA 3R RAINPROOF ;� ON OFF v V/ � lec For 60 through 600 Ampere Switches c D c D 611f 1s 413/16 2% 3'1e 7%2 5%. 4% 97/32 ' =1 DIMENSIONS - INCHES A M PS B A 0 tri '\.V 0 /� 0 POLES lP D A I NEMA 3R B GFN Fusible Switches, GUN Non- Fusib le Switches ca 0 ar NEMA 1 INDOOR /6 30 1, 2 A tM For 30 Ampere Switches l I NEMA1 an NEMA DIM ENSIONS· INCHES A M PS POLES c D 7 43132 52 7132 1615/32 85/s 517132 81/2 2215/16 107/s 77/ 16 127116 132 1/32 2, 3 30 713/16 2. 3 60 2, 3 100 2, 3 200 311/4 137/s 821132 2, 3 400 t5915i32 235132 1211/32 1521/32 2, 3 600 :1:661/s 235132 12 11132 1521/32 For GUN Non-Fusible Switch: 501;s" � For GUN Non-Fusible Switch: 545/s" t .E NEMA 3R RAINPROOF D ww POLES 2, 3 ON I w A RGFN Fusible Switches , RGUN Non- Fusib le Switches DIMENSIONS - INCHES A M PS 30 A B 911/32 615/ 16 41/s D 527/32 2, 3 60 1615/32 91/s 517132 81/2 2, 3 100 2215/16 102 7/32 77/ 16 127/16 2, 3 200 311/4 13 27132 821132 13 21/32 2, 3 400 t5915i32 235132 12 3/s 2, 3 600 :j:661 /s 235/32 123/s 1521132 15 2 1132 RGUN Non-Fusible Switch: 50118" �For RGUN Non-Fus1ble Switch: 545/s'' t For For 60 through 600 Ampere Switches All products in this catalog meet the new wire bending space requirements as identified in 1981 August, 1 985 c NEC Section 373-6 (b). .c om Catalog 30-150 Page 6 RHFN·362 HFN-362 Fusible®, 240 Volts Ac or 250 Volts De POLES AMPS 2-Pole 2-Wire 30 60 100 200 400 600 800 1200 6 2-Pole 3-Wire SN 30 60 100 200 400 600 800 1200 � �� contacts cannot close with door open. Both functions are defeatible by authorized personnel Line terminal shield prevents ac­ ��� De-ion arc chute interrupts and cools hot arcs; prevents arc damage • Embossed metal nameplate per­ amperes and horsepower rating • Front-operated handle permits close ganging. Handle is integral part of switching mechanism; provides permanent control of or ON position • Red vinyl cover instantly identifies • Blades visible in open or closed position • �:����(j) Tin-plated current-carrying parts w for ease of operation Easily accessible fuse holders suitable for standard, time delay and Type J fuses (Type J for ww enclosures thru 600A) • Ample knockouts and wiring room � RHFN-221 RHFN-222 RHFN-223 RHFN-224 RHFN-225 RHFN-226 RHFN-227 RHFN-228 Order2 Pole switch from above Select neutral kitfrom neutral table on page9 � HFN-321 HFN-322 HFN-323 HFN-324 HFN-325 HFN-326 HFN-327 HFN-328 Order 3 Pole switch from above Select neutral kitfrom neutral table on page9 30 60 100 200 400 600 ! RHFN-321 RHFN-322 RHFN-323 RHFN-321 RHFN-325 RHFN-326 RHFN-327 RHFN-328 �""�" switch from above Select neutrat kilt rom neutral table on page9 NEMA12 @ CAT. NO. WHFN-221 WHFN-222 WHFN-223 WHFN-224 WHFN-225 WHFN-226 . . .. .. . . . . .. JHFN-221 JHFN-222 JHFN-223 JHFN-224 JHFN-225 JHFN-226 . . .. . . ...... � � HORSEPOWER RATING NEMA4 STLS.STEEL CAT.NO. Order2 Pole switch from above Select neutral kitfrom neutral table on page9 WHFN-321 WHFN-322 WHFN-323 WHFN-324 WHFN-325 WHFN-326 . . . . . · · - · - · Order 3 Pole switch from above Select neutral kitfrom neutral table on page9 HFN-421 HFN-422 HFN-423 HFN-424 HFN-425 HFN-426 � 240 VOLTS @ AcSTD. 1¢ Order2 Pole switch from above Select neutral kitfrom neutral table on page9 r 34> MAXIMUM 14> 34> 250 VOLTS De 1112 3 7112 15 3 10 15 5 10 20 40 1112 3 71!'.< 15 3 10 15 5 10 20 40 JHFN-321 JHFN-322 JHFN-323 JHFN-324 JHFN-325 JHFN-326 · · · - · - 3 7V 15 25 50 75 7112 15 30 60 125 200 3 7V 15 25 50 75 7112 15 30 60 125 200 3 7'\> 15 25 50 75 7'12 15 30 60 125 200 50 · · - · - · .. ·- switch from above Select neutra kittrom neutral table on page9 JHFN-421 JHFN-422 JHFN-423 JHFN-424 50 600VOLTS Ac, 600VOLTS Dc,FUSIBLE®NEMA 1, 3R, 4and 1 2 ENCLOSURES Diamond-pointed break jaws pro­ have lubricated moving parts • � 30 60 100 200 400 600 800 1200 Fusible(]), POLES free of pitting and burning • I<<� ���� 4-Pole 4-Wire proof switching mechanism long blade life; keep contact area • ��� 3-Pole 4-Wire SN Quick-make, quick-break, tease­ .E • 240 Volts Ac 30 60 100 200 400 600 800 1200 lec handle, indicates position 3-Pole 3-Wire tri contacts; can be padlocked in OFF Order2 Pole switch from above Select neutral kitfrom neutral table on page9 ca manently identifies catalog number, Fustble ®, � HFN-221 HFN-222 HFN-223 HFN-224 HFN-225 HFN-226 HFN-227 HFN-228 lP cidental contact with line terminals NEMA 3 R RAINPROOF CAT. NO. ar opEMed when switch is ON ; • @ NEMA1 INDOOR CAT.NO. Dual cover interlock prevents ac­ cidental operation; door cannot be an fin ish resists rust • JH tM Bonderized UL Listed organic • WHFN-362 240 VOLTS Ac, 250VOLTS Dc,FUSIBLEcvNEMA 1,3R,4 AND 1 2 ENCLOSURES Features-Specifications • ua ls Heavy Duty Safety Switches Fusible �� AMPS 30 60 100 200 400 600 800 1200 Fusible CV, �:����(j) ��� 600 Volts Ac ® 600 Volts De � @ NEMA1 INDOOR CAT. NO. HFN-261 HFN-262 HFN-263· HFN-264 HFN-265 HFN-266 HFN-267 HFN-268 600 Volts, 30 60 100 200 400 600 800 1200 6 � Ac NEMA 3 R RAINPROOF CAT.NO. RHFN-261 RHFN-262 RHFN-263 RHFN-264 RHFN-265 RHFN-266 RHFN-267 RHFN-268 NEMA4 STLS.STEEL CAT.NO. WHFN-261 WHFN-262 WHFN-263 WHFN-264 WHFN-265 WHFN-266 · - · · · · ...... HORSEPOWER RATING NEMA 12 CAT.NO. JHFN-261 JHFN-262 JHFN-263 JHFN-264 JHFN-265 JHFN-266 . . .... ...... ® HFN-361 HFN-362 HFN-363 HFN-364 HFN-365 HFN-366 HFN-367 HFN-368 RHFN-361 RHFN-362 RHFN-363 RHFN-364 RHFN-365 RHFN-366 RHFN-367 RHFN-368 (j) For neutral k1ts refer to page 9. ® 30-600 amp switches are available with provision for Class J fuses. To order, addsuffix J to catalog number. @ 800 and 1200 ampere switches have provision for Class L Line and load terminals suitable for fuses(1 fuse per pole) @ NEMA 12 (30 to 200 Amp.) enclosures are available with COpper Or aluminum Wire knockouts.To order.addsuffixDto catalog number. WHFN-361 WHFN-362 WHFN-363 WHFN-364 WHFN-365 WHFN-366 ...... · · · - · · JHFN-361 JHFN-362 JHFN-363 JHFN-364 JHFN-365 JHFN-366 . ..... . ..... Ac STD. MAXIMUM 480V 600V 480V 600V 14> 14> 14> 14> 3 5 10 25 3 10 15 30 7112 20 30 50 VOLTS De 250 10 25 40 50 600 10 25 40 50 I·�� 1 o��· �3:;, 03:;,· 5 15 25 50 100 150 7112 15 30 60 125 200 15 30 60 125 250 400 20 50 75 150 350 500 50 @Switches are available with proviSIOn for tang terminals. To order, add sufftx A to catalog number. @Ac rated only. CV For Class R fuse kits. refer to page 14. For new NEG terminal data see page 9. For price information see Bryant Price List BPL 30-125 August, 1 985 .c om Catalog 30-150 Page 7 ua ls Heavy Duty Safety Switches Fusible and Non-Fusible RHFN-362 Fusible,® 600 Volts Ac Door interlock prevents door from POLES 3·Pole 4.Wire SN Star mounting feet assure ���< easy mounting • UL Listed File E5189 • GSA Certified File • Meet Federal Spec. WS-865c switch esfrom page10 and select neutral ki tfrom page9 4·Pole 4-Wire ���{ 30 60 100 200 400 600 I 2-Pole (j) 2-Wire 30 60 100 200 400 600 ca n Use3 Pole below Non-Fusible, 240 Volts, Ac 5-����G) 30 60 100 200 400 600 tri rn lec .E w ww ! Non· Fusible. 240 Volts Ac Application Data • All switches are Underwriters' Laboratories listed and suitable for use as Service Entrance Equipment when neutral is provided or grounding kit is employed. • All Heavy Duty Safety Switches, when used with Class R or J fuses, are rated for 100,000 amps RMS available. August, 1985 HFN-461 HFN-462 HFN-463 HFN-464 HFN-465 HFN-466 lP Meet NEMA Spec. KS1-1975 30 60 100 200 400 600 800 1200 Fusible, 600 Volts Ac (800-1200 amps) LR-28115 • @ NEMA1 INDOOR CAT.NO. AMPS ! NEMA3 R RAI NPROOF CAT.NO. tM opening when switch is energized • r-·- closed; permits padlocking an Door latch securely holds door """"�" switch esfrom page10 and select neutral ki tfrom page9 �-·- � NEMA4 STLS.STEEL CAT.NO. NEMA12 @ CAT. NO. �:�t;�g��3" select neutral kitfrom page9 Order3 Pole switch esfr«?n page10 a n d select neutral kitfrom page9 HUN-321 HUN-322 HUN-323 HUN-324 HUN-325 HUN-326 ! Use3 Pole below RHUN-321 RHUN-322 RHU�·323 RHUN-324 RHUN-325 RHUN-326 n 30 60 100 200 400 600 800 1200 � HUN-261 HUN-262 HUN-263 HUN-264 HUN-265 HUN-266 HUN-267 HUN-268 RHUN-261 RHUN-262 RHUN-263 RHUN-264 RHUN-265 RHUN-266 RHUN-267 RHUN-268 nr 30 60 100 200 400 600 800 1200 6 � HUN-361 HUN-362 HUN-363 HUN-364 HUN-365 HUN-366 HUN-367 HUN-368 RHUN-361 RHUN-362 RHUN-363 RHUN-364 RHUN-365 RHUN-366 RHUN-367 RHUN-368 nn 4-Wire 30 60 100 200 400 600 HUN-461 HUN-462 HUN-463 HUN-464 HUN-465 HUN-466 CD For neutral kits refer to page9. (2)30-600 amp switches are available w1th provision for Class J fuses. To order, add suffix J to catalog number. @BOO and 1200 ampere switches have provis1on tor Class L fuses (1 fuse per pole). @NEMA 12 (30 to 200 Amp.) enclosures are ava1lable w1th knockouts. To order, add suffix 0 to catalog number. For new NEC terminal data see page 9. For price information see Bryant Price List BPL 30-125 MAXIMUM 480V 600V 480� 3<1> 3<1> 3<1> 5 15 25 50 100 150 7V2 15 30 15 30 60 60 125 1 25 250 200 400 VOL TS De 600V 250V 600V 3<1> 20 50 75 150 350 500 ! Use3 Pole below WHUN-321 WHUN-322 WHUN-323 WHUN-324 WHUN-325 WHUN-326 I 15 30 60 125 250 400 20 50 75 150 350 500 480V 600V 480V 600V 2<1> 2<!> 2<1> 2<1> Use3 Pole below 240V 240V 480V 600V 1<1> 1<1> 3<1> 3<1> JHUN-321 JHUN-322 JHUN-323 JHUN-324 JHUN-325 JHUN-326 3 10 15 15 71/2. 15 30 60 100 200 ��v 240V 240V 480V 6 1m 1<1> 1d> WHUN-261 WHUN-262 WHUN-263 WHUN-264 WHUN-265 WHUN-266 .. .. . . . .... . WHUN-361 WHUN-362 WHUN-363 WHUN-364 WHUN-365 WHUN-366 · · · · · · 7112 10 25 JHUN-261 JHUN-262 JHUN-263 JHUN-264 JHUN-265 JHUN-266 .. .. . ... .. . 20 30 50 15 30 50 50 40 50 . 240V 240V 480V 600V 1d> 1d> 3<1> 3d> 15 30 60 JHUN-361 JHUN-362 JHUN-363 JHUN-364 JHUN-365 JHUN-366 . . . . 125 250 400 . . . . ... 20 50 75 150 350 500 50 240V 600V 480V 600V 2d> 2<1> 3d> 3<1> Non-Fusible, 600 Volts Ac, 250 Volts De / 4-Pole AcSTD. 25 50 50 Non-Fusible, 600 Volts Ac 3-Pole G) 3.Wire HORSEPOWER RATING 480V 600V 480V 600V 3<1> 3<1> 2<1> 2<1> Non· Fusible, 600 Volts Ac, 600 Volts De �:����G) @ ar • JHFN-362 240, 480, 600VOLTS Ac, 250, 600VOLTS De, FUSIBLECfi AND NON-FUSIBLE NEMA 1, 3R, 4 AND 12 ENCLOSURES Features-Specifications • WHFN-362 JHUN-461 JHUN-462 JHUN-463 JHUN-464 10 20 30 50 25 50 50 50 20 50 60 125 250 400 30 60 75 150 350 500 5 10 20 @ SwitChes are available w1th proviSion for tang term1nals order, add suff1x A to catalog numt'er. @ Ac rated only ® For Class R fuse k1ts. refer to page 14. @ These are 2-phase rat1ngs To .c om Catalog 30-150 PageS Heavy Duty Safety Switches Dimensional Data NEMA 1 INDOOR c DIMENSIONS - INCHES POLES B -----1 D � D CONDUIT SIZES, INCHES 2501600 Volt HFN Fusible Switch es 2, 3® 2, 3 2, 3(j) 2, 3 2,3 2, 3 2,3 2, 3 2, 3 2, 3 71/z 9 9 9 1013/1 6 1313/16 235/32 235/32 3911/16 4211116 413/32 517/32 517/32 517132 77!16 821/32 1211/32 1211/32 121/4 121/4 627/32 97/a 97/a 97/a 121/16 1313/32 1521/32 1521/32 1525/32 152 5/32 1/2,3/4, 1 112,3/4, 1, 1'/4,1112,2.21 12 1/2, 3/4, 1' 11/4, 11/2, 2, 21/2 112,3/4, 1, 11/4,11 12,2,2112 112,3/4, 1, 1114,11/z, 2 lfz,3/4,11/z, 2, 2'12, 3 31/2,4 3112,4 71/z 9 9 1013/16 1313/16 235/32 235132 3911/16 4211/16 413/32 517/32 517/32 77116 821/32 1211/32 1211/32 121/4 12114 62 7/32 97/a 97/a 121/16 1313/32 1521/32 1521/32 1525/32 1525/32 1/2, 3/4, 1 1/z,3/4,1,11/4, 11/2, 2, 21/2 1/z,3/4, 1, 11/4,1112, 2, 2112 1/2, 3/4, 11/4, 11/2,2 1/2,3/4,11/2,2,21/2, 3 3112, 4 31/2,4 ua ls T)1���\ r41 B A 99/32 1815/16 167 116 1815/16 287116 375/a 5915/32 66':a 653 1132 735/32 30 30 60 60 100 200 400 600 800 1200 2501600 Volt HUN Non - F usible Switch es 2, 3(j) 2, 3 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 For30 Ampere Switch es For 60 th rough 1200 Ampere Switch es (j)250 Volt units only tM NEMA 3R RAINPROO F 99/32 167 116 16711 6 28711 6 375/a 501/a 545/a 60 6429/32 30 30 60 100 200 400 600 800 1200 an �c=:J AMPS ' ! I CONDUIT SIZES, INCHES 2501600 Volt RHFN Fusible Switch es I-- pO 'v -o l 103116 18151 16 1815,16 287-'16 375 8 5915132 661·8 6531 32 755132 77116 8718 87's 1013/ 16 131 3116 235132 235132 3911'16 42111 16 413/16 517/32 517/32 77116 821/32 12318 123/8 129/32 129/32 75132 93/s 93/8 10314 131/2 1521/32 1521/32 1525/32 1525/32 1/2,3/4, 1' 1114, 1112,2 1/2, 3/4, 1' 11/4, 11/2,2 1/2, 3/4, 1, 11/4, 11/2, 2 112,3(4, 1' 11/4, 11/2,2 112,3/4, 11/2, 2, 21/2,3 413'16 517/32 517/32 77/16 821132 123/8 123/a 129/32 129132 75/32 93/8 93/a 103/4 13112 1521/32 1521/32 1525/32 1525/32 1/2,3 14, 1,11/4,11/2,2 112,3/4,1, 11/4,1112,2 112,314,1, 11/4,11 12, 2 1/2,3/4,1, 11/4,11/2, 2 112, 314,1112,2, 21/2,3 3/4, 1,11/4, 11/2,2 3/4,1, 1114,11/2,2 3/4, 1, 11/4, 11/2,2 314,1' 1114,11/2,2 2, 21/2, 3 �"c 2501600 Volt RHUN Non - Fusible Switch es D� For30 Ampere Switch es For 60 th roug h 1200 Ampere Switch es 30 30 60 100 200 400 600 800 1200 ar /JLQ ca v \V B -----, lP r---u 2, 3(j) 2, 3 2,3 2, 3 2, 3 2,3 2,3 2, 3 2,3 (j)250 Volt umts only 2, 3(j) 2, 3 2, 3 2, 3 2, 3 2, 3 2,3 2c 3 2,3 30 30 60 100 200 400 600 800 1200 103/16 1815116 18151 16 287'16 37518 501;8 545/8 60 6429132 77 116 87/a 87 1a 1013/16 1313/16 235/32 235132 3911 116 4211'16 3/4, 1' 1114,1112, 2 3/4,1,11/4,1112,2 3/4,1, 1114,11/2,2 3/4,1, 11/4, 11'2,2 2, 2112, 3 NEMA 4 WATERTIGHT STAINLESS STEEL, NEMA 12 DUST-TIGHT & OIL-TIGHT INDUSTRIAL l D � ' I= .E A ' ,-v- v .P �c-----1 v 1--- D _______, For30 th rough 200 Ampere Switch es rr t� Jfc=J :� lec TlI '--- c _j tri r B {'\ !fJ h�B�·J l � rc � D -1 __, For 30 Ampere, 250 Volts Switch es r-- w p I A ww I I D 0 1 AMPS F c DIMENSIONS - INCHES D A B 1011 16 1815116 1815'16 287'16 375/a 6117/32 683 1 6 77'16 9t,a 91 18 10151 16 1315/16 235!32 235/32 4 21/32 517.'32 517132 77/16 821132 1213/32 1213/32 615116 93/a 93/a 103/4 131/2 177/16 177116 1011'16 1815116 1815116 287.16 37518 523/16 5611116 77116 91/8 9118 10151 16 1315Jt6 235/32 235132 421 132 517132 517132 77ft6 821/32 1213/32 1213/32 6151 16 9318 93/8 103/4 131/2 177116 177116 1311116 1815/16 18151 16 287'16 37518 6117'32 683/16 719/32 8?13 8?13 1011 116 1311/16 235!32 235/32 421/32 517/32 517/32 771 16 821/32 1213/32 1213/32 615/16 9 3/s 93/a 103/4 131/2 177 116 177116 719/32 87/a 87/a 10111 16 1311/16 235/32 235/32 421/32 517/32 517132 77/16 821/32 1213/32 1213/32 615/16 93/a 93/a 103/4 131/2 177116 177/16 2501600 Volt WHFN Fusible Switch es �.3® 2,3 2,3 2,3 2,3 2,3 2,3 30 30 60 100 200 400 600 2501600 Volt WHUN Non- Fusible Switch es 2,3® 2,3 2,3 2,3 2,3 2,3 2,3 30 30 60 100 200 400 600 2501600 Volt JHFN Fusible Switch es 2,3(j) 2,3 2,3 2,3 2,3 2,3 2,3 30 30 60 100 200 400 600 2501600 Volt JHUN Non - F usible Switch es � For 400 th rough 600 Ampere Switch es POLES 2,3<D 2,3 2,3 2,3 2,3 2,3 2,3 30 30 60 100 200 400 600 1311/t6 1815/16 1815116 287 116 37518 523/ 16 56111 16 (j) 250 Volt units only All products in this catalog meet the new wire bending space requirements as identified in 1981 NEC Section 373-6 (b). August, 1985 .c om Catalog 30-150 Page 9 AMPS No. ofw1res 30 60 100 200 400 or 600 MIN. WIRE SIZE MAX. WIRE SIZE TYPE #14 #14 #14 #4 250 MCM 30 1 0 #8 #3 1'0 200MCM 750MCM 300MCM 750MCM Cu Cu AI Cu AI Cu AI Cu Cu Cu,AI AMPS or 600 800 1200 NK-400 l I NEUTRAL KITS ,, \ 8 . 1 t... '� '· •• FIELD INSTALLED IN NON-FUSIBLE AND FUSIBLE HEAVY DUTY SWITChES AMPS -�RFK-3 ._ 30 60 100 200 400 600 800 1200 NEMA1 N-K30 @ NK60 NK100 NK200 NK400 NK600 NKBOO NK1200 --- i l 30 . 60@ . 60@ 100@ 100@ 200 400 of ��� j 1 • 1 1 1 1 1 2 600 . #14 #14 #12 #12 #12 #6 10 10 TYPE �� 1 1 1 1 1 1 2 1 2 1 #6 #4 1 0 1 0 10 �g� I! ggg 750MCM ! 350MCM Cu Cu AI CuAI Cu CuAI CuAI CuAI CuAI i Cu CAT. NO. EK-1® EK-2 EK-3 EK-5 EK-4®® MAX. RATING 200A 600A NK60 NK100 NK200 NK400 NK600 NKBOO NK1200 i MAX. WIRE SIZE GNK-6 GNK-20 GNK-60 �N""'Kcc30cc-@"g�--- DESCRIPTION or I ...... -1------ .. SIZE es SIZE ! of ;es CATALOG NUMBER -L- For use with heavy duty safety switches only. Kit will reject all fuses except class R. Only one kit required for a three pole switch. tri AMPS· AMPS NEMA 3R, 4, 12 I Ii i GROUNDING KITS - --·------ CLASS R FUSE CLIP KITS®® RFK-5 MIN. WIRE SIZE 30 Amps, 250 Volts® 30, 60 Amps, 600 Volts, 60 Amps, 250 Volts® All 100 and 200 Amp Switches® All400 and 600 Amp Switches® All BOO thru 1200 Amp Switches CATALOG NUMBER lP RFK-4 RFK-2 Cu AI Cu1AI Cu1AI Cu·AI Cu•AI Cu Cu Cu. AI Cu,AI Cu·AI ca .:t/ #8 #3 #3 1•0 250MCM 750MCM 300MCM 750MCM 750MCM 750MCM tM �/--�r-�. I RFK-1 #14 #14 #14 #14 #6 250MCM 30 , 10 : 10 10 ar � "� TYPE Electrical interlock kits are available for H-600 type heavy duty safety switches. The kit contains a contact block having 1 NO and 1 NC contact rated 10 amps resistive and 6 amps inductive, mounted on a steel bracket with a control arm. The control arm is actuated by the switch mechanism and breaks the control circuit before the safety switch opens. Not available for motor circuit switch. I I ! i GNK DESCRIPTION MAX. WIRE SIZE an ELECTRICAL INTERLOCK KITS · i MIN. WIRE SIZE No. : of wires : 30(j) 30 @ 60 100 200 400 EK-1 r- DOUBLE THROW HEAVY DUTY PLUG- GENERAL DUTY ua ls TERMINAL General and Heavy Duty Safety Switches Modifications and Accessories D.ATA FOR SWITCHES THAT COMPLY WITH 1981 NEC SECT. 373-6 (b) --+----6""'0-�A----i ..---�----� CAT. NO AMPS 30A, 250V 30A, 600V/60A, 250V 60A, 600V 100/200A, 250/600V 400/600A, 250/600V i RFK-1 RFK-2 RFK-3 RFK-4 RFK-5 INTERCHANGEABLE RAIN PROOF HUBS ! lec i--- R1H-200 I All rainproof switches except 400 and 600 amperes are shipped with cutout covered by a plate. Figure 1 shows a hub mounted in posilion. Hubs smaller than 2" can be used on 200 ampere switches by ordering an adapter plate R 1HA. l i I I .E i ST-4 w ww August, 1985 ! '--- % 1 1114 11/z 2 2 2112 3 Adapter Plate SWITCH SIZE 30 thru 100 Amps 200 Amps CAT. NO. ROH-075 ROH-100 ROH-125 ROH-150 ROH-200 R1H-200 R1H·250 R1H-300 R1HA MYERS-TYPE HUBS r I '' DESCRIPTION i All 400 and 600 ampere rainproof switches are shipped with plain tops, no cutouts. Order zinc or chrome Myers-type hubs from the �able below; hubs are shipped separately. i Rainproof switches 30 through 200 amperes with plain tops for use with Myers-type hubs, are available in minimum ordering quantities of 100 units. (Mixed 30, 60, 100 and 200 amperes.) . (j) 250V Sw1tch @ 600V Switch @ NEMA1 @ ST-6 HUB DIA. INCHES DESCRIPTION NEMA3R @ For factory installation add suffix A HUB DIA. INCHES ZINC CAT. NO. CHROME CAT. NO. 1/z % 1 1114 11/z 2 2V2 3 31/z 4 ST-1 ST-2 ST-3 ST-4 ST-5 ST-6 ST-7 ST-8 ST-9 ST-10 CST-1 CST-2 CST-3 CST-4 CST-5 CST-6 CST-7 CST-8 CST-9 CST-10 @ Cannot be installed when conduit entrance is at top right. ® Excepl four blade, four pole and double throw switches. @ This unit is only factory mounted. ® For 250V applicalion only. Use NK60 for 600V. to catalog number to specify. For price information see Bryant Price List BPL 30-125 .c om Catalog 30-150 Page 1 0 XUN-321 • Double throw switches are designed for use as transfer switches when load is supplied from two sources. Switch opens one circuit and closes another simultaneously, or isolates both circuits. DOUBLE THROW NEMA1, 3R, 250, 600 V.A.C. FUSIBLE AND NON-FUSIBLE POLES ii 2-Pole 2-Wire r t"' 240 Volts Ac AMPS 3Pole 3 Wire Switch Below 30 60 100 200 400 600@ sss Non- Fusi b le , 2-Pole 2-Wire 3Pole 1 3 Wire Switch Below ! �Pole o,,., 3Pole, 3 Wire Switch Below 30 XUN-321 I ca tri Designed to meet the demands of heavy industry for a compact, non-fusible switch with visible contact disconnect. ww • E 2-Pole 2-Wire I 60 100 200 4ll0 600G) Ill """""" Ill 32 46 127 #12·#2 #12·1/0 #4·300MCM 60 100 4-Pole 4-Wire Ill\ <-<-<< II II 53 54 87 170 260 I !0' " � 03Pole, 3 Wire Switch Below I i XUN- 362 XUN-363 XUN-364 XUN-365 XUN- 366 I 22 39 100 135 215 3Pole, 3 Wire Switch Below 31 50 110 191 256 RXUN- 362 RXUN-363 RXUN- 364 RXUN-365 RXUN-366 �- 33 46 XUN-462 XUN-463 MAXIMUM H.P. RATINGS 600 VAC 250 VDC AMPS 120VAC 240VAC 480VAC 600VAC 250VDC 30 60 100 200 5 10 15 10 20 30 60 20 40 75 100 25 60 75 100 71/2 15 25 40 Accessories Aux. Switch Kits* AMP RATING SWITCH USED WITH CONTACT ARRANGEMENT KIT STYLE NO. 30,60,100 200 200 1A, 1B 1A, 1B 2A's, 2B's 178C265G05 178C619G01 178C619G02 Permtts fteld mounttng of an auxthary swttch for separate control ctrcutt applica­ tions. Each switch includes three soldered, identified leads. NEUTRAL KITS Double Throw Switches CAT. NO. DESCRIPTION XLK111 Universal Type --�-- ---- 3-Pole 3-Wire NEMA3R Volts Ac 60 100 200 400 600@ II """" II 20 39 106 163 224 ELECTRICAL INTERLOCK KIT ---- I i Non-Fusible, 6 0 0 l) -----.;? ,-- I lec Application Data �- #14·#2 #14-1/0 #4-300MCM NEMA1 XFN- 361 XFN- 362 XFN-36 3 XFN- 364 XFN-365 i 84 130 .E 6 Pole switches are listed under UL E-5189 w • sss """""" ))) SHIP WT. LBS. CAT. NO. AMPS 30 60 100 200 400 3-Pole 3-Wire 15 I I Volts Ac 20 31 85 160 250 310 XUN- 322 3-Wire 60 I Features-Specifications XUN-323 100 I! I MOTOR CIRCUIT SWITCHES XUN-324 200 """""" XUN-325 400 • Insulated shield prevents accidental Ill I XUN- 326 600<D contact with line terminals _J 4-Pole 60 XUN-422 • Blades visible in open or closed i 4-Wire 100 XUN-423 position 200 XUN-424 II II -<-<.c:< • Cover interlock prevents cover from II II opening when switch is energized. <D Ac ratmg only. Interlock release permits cover to be MOTOR CIRCUIT SWITCHES opened for switch inspection. 6 Pole Non-Fused Complete • Trunk-type latches keep cover tightly closed; provides an effective CATALOG NUMBER AMPS dust-resisting seal. • Over-center quick-make, quick-break switching mechanism prevents NEMA 12 NEMA 1 NEMA 3R teasing of contacts 30 SDSN6 030 RDSN6030 JDSN6030 SDSN606 0 RDSN606 0 JDSN6060 60 • Large wiring gutters facilitate wiring SDSN6100 RDSN6100 JDSN6100 100 and provide easy access to terminals 200 SDSN6200 RDSN6200 JDSN6200 • Handle can be padlocked in OFF , position by up to three padlocks TERMINALS ARE SUITABLE FOR EITHER COPPER OR ALUMINUM CABLE • Cover can be padlocked in closed SWITCH WIRE RANGE position RATING • Neoprene gasket seals out moisture ALUMINUM COPPER and dust from switch assembly #12-#2 30 #14·#2 60 100 200 POLES 18 24 61 125 XFN-321 XFN-322 RXFN- 322' XFN-323 RXFN-323 XFN- 324 RXFN- 324 XFN-325 XFN- 326 240 Volts Ac 30 60 100 200 400 II """" II NEMA3R NEMA1 SS i'i'i SHIP WT. LBS. CAT. NO. 30 60 100 200 3-Pole 3-Wire Fusible, 600 an F u si ble , tM Application Data SDSN6030 ar Features-Specifications DOUBLE THROW SWITCHES • Cover interlock (through 600A prevents door from opening when switch is energized • Positive-make, quick-break operating mechanism • Handle may be padlocked in top ON, neutral, or bottom ON positions • All switches except 600 Amps are UL Listed SDSN6030 lP XUN-321 ua ls Double Throw Switches Motor Circuit Switches ---�-� L For price information see Bryant Price List BPL 30-125 AMPS CAT. NO. 200 400 600 XNK-2 XNK-4 XNK-6 l ----__ -r--- J -�-_L_ I I _j August, 1985 .c om Catalog 30-150 Page 1 1 NEMA 1 Double Throw Switches Motor Circuit Switches Dimensional Data INDOOR DOUBLE THROW SWITCHES CAT. NO. F usible Switches XFN-3 61 XFN-3 62 XFN-3 63 XFN-3 64 XFN-3 65 I I I I I B c 151/s 225/s 345!32 5 13/64 I 6519/64 7019/64 101/4 121/2 131/2 173132 205!32 225f32 33/4 61/2 61/2 103/32 1 15f32 135f32 1/2, 3/4, 1' 11/4 3/4,1' 11/4,11/2, 2 11/2,2,21/2 2,21/2 21/2,3 3,31/2 345!32 345!32 385!32 5 1%4 651%4 131/2 131/2 1415/32 175!32 205f32 61/2 61/2 613f 16 103132 1 15/32 1/2,3/4, 1' 11/4 3/4,1' 11/4,11/2,2 11/2,2 2,21/2, 11/2 21/2,3 151/s 225/s XUN-3 23 211/s XUN-3 24 3151/64 XUN-3 25 4 11%4 XUN-3 26 4919/64 Not to be used tor construction purposes unless approved. B I c CONDUIT SIZES, INCHES 1/2,3/4,1, 11/4 3f4, 1' 11/4,11/2,2 101/4 33/4 121/2 61/2 131/2 175/32 61/2 103132 11/2,2,21/2 205132 1 15132 21/2, 3 225132 135132 XUN-422 2 11/s 175/32 XUN-423 2 11/s XUN-424 3151/64 175/32 2113/32 61/2 61/2 103132 11/4,11/2,2 3. 31/2 3 f4, 1' 11/4, 11/2, 2 11/4, 11/2,2 11/2,2,21/2 3/4,1' 11/4, 11/2,2 XUN-262 225/s 121/2 61/2 XUN-263 2 11/s 131/2 11/4, 11/2,2 XUN-264 3151/64 175132 61/2 103/32 XUN-265 4119(64 205/32 115/32 21/2,3 11/2, 2,21/2 XUN-266 491%4 225132 135/32 XUN-3 62 225/s 121/2 61/2 XUN-3 63 211/s 131/2 3 151/64 175132 61/2 103 132 11/4, 11/2,2 XUN-3 64 XUN-3 65 4 11%4 205/32 1 15132 21/2,3 XUN-3 66 491%4 225132 135/32 tM XFN-3 21 XFN-3 22 XFN-3 23 XFN-3 24 XFN-3 25 XFN-3 26 A XUN-3 21 XUN-3 22 ar i CONDUIT SIZES , INCHES DIMENSIONS -INCHES DIMENSIONS -INCHES A an ! For 30 t h rough 600 Ampere Switch es CAT. NO. ua ls Non-Fusible Switches 3, 31/2 3/4, 1' 11/4, 11/2,2 11/2,2,21/2 3, 31/2 XUN-462 2 15/32 175/32 61/2 3/4, 1' 11/4, 11/2,2 XUN- 463 215132 175132 61/2 11/4, 11/2,2 -- lP NEMA JR, OUTDOOR DOUBLE THROW SWITCHES lec tri ca F usible Switches I CAT. NO. DIMENSIONS -INCHES RXFN-3 22 23 RXFN-3 23 341/2 4327/64 RXFN-3 24 B A c 1415/16 7 1415/ 16 CONDUIT SIZES , INCHES 3/4, 1' 11/4, 11/2,2 175f32 7 103132 11/2,2,21/2 1415116 14151 1 6 175132 205/32 225/32 7 7 103132 115132 135!32 3/4, 1' 11/4, 11/2,2 11/4,11/2, 2 1112,2,21/2 21/2,3 3,31/6 11/4, 11/2,2 Non-Fusible Switches RXUN-3 62 RXUN-3 63 RXUN-3 64 RXUN-3 65 RXUN-3 66 151/2 2 1 '12 3151/64 4119/64 4919/64 ww w .E MOTOR CIRCUIT SWITCHES 6 Pole Un its- 30, 60, 100 AMPERES 6 Pole Units- 30, 60, 1 00 AMPERES [lo A' II DIMENSIONS -INCHES AND MM ENCLOSURE TYPE ON OFF LL �--6 Pole Un its- 200 AMPERES A IN. MM IN. 476 NEMA3R 183/4 183/4 NEMA 12 183/4 NEMA1 c MM IN. 181/2 470 227 476 181/2 470 815116 815116 476 181/2 470 815/16 227 3FI16 799 217116 545 799 217116 545 93/4 93/4 248 317116 2 17116 545 93/4 248 MM 227 6 Pole Units- 200 AMPERES NEMA 1 NEMA3R NEMA 1 2 3Fi16 799 All products in this catalog meet the new wire bending space requirements as identified in 1981 August, 1985 B NEC Section 373-6 (b). 248 .c om Cata l o g 30-150 ww w .E lec tri ca lP ar tM an ua ls Pag e 1 2 Westinghouse Electric Corporation Bryant E l ectric, Circuit Protective Devices Bridg eport, Connecticut 06606 August, 1985 30-150 Distri bution a n d Contro l Busi ness U n it Standard Distri bution Prod u cts Division Pittsburgh, Pennsylva n i a , U . S.A. 1 5220 Page 1 \, Safety Switches Octo ber 1 991 Supersedes Catalog 30-1 50, pages 1 - 1 2, dated M a rch, 1 989 For standard terms of sale, refer to Sel l i n g Policy 25-000 Mai led to: E, D, C/30-1 00A • General Duty Heavy Duty Double Throw Motor Circuit Switches ua ls • • w .E lec tri ca lP ar tM an • ww .c om Cata log Westinghouse Electric Corporation .c om Catalog 30-150 Page 2 Heavy Duty Safety Switches Features De-ion a rc ch ute i nterrupts a n d cools a rcs for longer switch l i fe ua ls Star mo unting h o les at top and bottom for easy 2, 3 or 4 point mou nt i n g . Door latch securely holds door closed ; permits padlocking in position Diamond poi nted jaws p revent burning and pitting of cu rrent-ca rrying su rfaces U n b reaka ble steel cross arm controls contacts; provides positive b l ade a l i g nment B l ades a re visible i n open o r closed position tri ca ass J Fuse Provisions are provided i n 600V, 30-600A switches. When J fuses a re req u i red, the l oad blocks can easily be moved to these pre-drilled a n d tapped mounting provisions, eliminating the need to order special switches from the factory. Fro nt-operated handle with h i g h-vis i b i l it y red vi nyl sleeve lec .E w ww Underwriters Laboratory Label lv-'""'P<:c:ible fuse cl ips are spring rei nforced for lower operating temperatu res and long-l ife performance Door interlock prevents cover from bei n g opened when switch i s energ ized I n s u l ated shield p revents accidental contact with l i ne terminals. The unique design a l l ows the .----l i ne conductors to be i n stal led by simply loosening two screws a n d sliding the line shield downward. lP ar tM an I n struction l a bel for Quick-make, q u ick-break mechan ism p revents contact teasing Ample knockouts on a l l fou r sides and at rear of enclosu re Pressure-type a l uminum l i ne a n d load term i n a l s can be used with 60 or 75°C copper o r a l uminum w i re Line and load bases constructed of h i g h-impact pheno lic 0 October 1 991 .c om Cata log 30-150 Page 3 Heavy Duty Safety Switches Features @ Dual Purpose Interlock: Prevents switch from bei n g t h rown O N with cover open; p revents cover from bei ng opened u n less switch is O FF. Authorized perso n nel can bypass both conditions by rotat­ i n g the i nterlock lock defeater screw located a bove the h a ndle. Rating Identification: Westinghouse Teaseproof Switch Mechanism: Over-center des i g n with positive d rive spring action maximizes strength of q u i ck-make, q u i ck­ break switch mechan ism. Pre­ vents contact teasing. The mechanism a l so provides a di rect mec h a n ical drive for "fail safe" operati o n in the u n l i kely event of spring fa i l u re. ar tM Entire enclosure i s bonderized i n side and out and coated with baked on enamel for maximum d u ra b i l ity and resistance to rust. Scratches can not spread even though they extend through to the bare metal. All outdoor enclosu res are fabricated from g a l va n ized steel . an Durable Finish: ua ls Embossed nameplate e n h a n ces appearance and permanently identifies West i n g house name, catalog numbers, volts ampere and h o rsepower ratings. No need to open door to obta i n data 'Heavy Duty Safety Switcf. � Front Operated Handle: Steel Cross Arm and Vokes: Steel yokes in an impact-resis­ tant g l ass polyester i n sulating block firmly engage steel cross­ arm that d rives the mov i n g b lades a n d provi des positive b l ade a l i g nment. tri ca lP An i ntegral part of switch mech­ a n ism, the easi l y accessible h a n d l e perma nently controls contacts, permits close g a n g i n g , does not d i scon nect w h e n d o o r i s opened. Red v i n y l sleeve pro­ vides h i g h visibility; i n d icates h a ndle positio n (down for O F F; up for ON). The h a n d l e is pro­ vided with a V2' Dia. hole for hook stick operati o n . The vi nyl boot can either be d r i l led or removed when hook stick opera­ tion is required. ww w .E lec Padlocking: October 1991 Operating h a n d l e can be pad­ locked i n O F F position by t h ree padl ocks with %" h asps. Pre­ vents closing of contacts - a n essenti a l requi rement f o r heavy­ duty i n dustrial a p p l i cations. Handle can be padl ocked i n ON position by d ri l l i ng hole in h a n ­ d le a t position marked "X". Diamond-Pointed Break-Jaws: Movi n g contacts extend beyo n d t h e break-jaws, permitt i n g the brea king a rc to travel along the outside non current-ca rrying edges of jaws a n d b l ades. Pre­ vents b u r n i n g and pitt i n g of cur­ rent-ca rryi n g su rfaces. De-lon Arc Chute: Removable Interior Parts: Al l i nterior parts a re easi l y removable from the front i f replacement i s necessa ry. (See Price List 30- 1 90 ) Prevents a rc damage by i nter­ rupt i n g a n d coo l i n g hot a rcs. Mol ded materi a l of ch ute is car­ bonizing and track resistant. Pro­ longs switch l ife; a l lows maximum h o rsepower ratings permitted by UL. .c om Catalog 30-150 Page 4 . I / RGFN32 1 N PF3 1 1 N • • • • • • • • • • Easily access i b l e fuse h o l ders suitable for sta ndard a n d time delay fuses at maximum HP rat i n g s Ample knockouts a nd wiring room L i n e a n d load termi n a l s su ita ble for copper or aluminum w i re D o o r latch sec u rely h o l d s d o o r closed; permits padlocki ng S i n g l e cover i nterlock prevents door from o p e n i n g w h e n switch is energ ized o n a l l but 30A outdoor switches. 60-600A switches a re provided with a d u a l cover i nterl ock w h i ch a l so prevents the switch from being tu rned on when the cover is open. Star mou nting feet assure easy mounting U L Listed F i l e E 5 1 89 Meets NEMA Spec. KS 1 - 1 990 Meets Federa l Spec. WS-865c Type LD-30A outdoor a n d p l u g fuse Type ND-30-600A i ndoor and 60-600A outdoor Rated 1 00 K Amp RMS. When used with C l ass R fuses. See Table page 5 ® w • Application Data For use o n commerci a l , residential a n d l ig ht i n d ust rial appl ications. ww • • 30 II A l l switches a re U n de rwriters' Laboratories l i sted a n d suitable for use as Service E ntrance E q u i pment when neutral is provided or grou n d i n g kit is employed. For price information see Price List 30-125. For renewal parts data see Price List 30-190. CD The neutral is included when last digit is "N". ® Not approved for service entrance. 3 lied nP.LJtrrd kit ri l fi I i an Approx. Wt. Lbs. E a . Std. Pkg. Cat. No. tM Cat. No. 1 -Pole 2-Wire S N N E MA 3 R R a i n p roof N E MA 1 Indoor 3 PF2 1 1 N 10 Approx. Wt. Lbs. E a . RPF2 1 1 N Std. Pkg . Horsepower Rati n g s 120 v Max. Std. 4 5 2 v, 4 5 2 v, 240 v Max. Std. . . 2-Pole 3-Wire SN ill ar With Neutra l , 1 20/240 Volts Ac (2 B l ades, 2 Fuses) 30 3 PF31 1 N 10 RPF3 1 1 N 1 V2 3 �'10� Fusible, 240 Volts Ac - NEMA 1 and 3R Enclosures Poles Amps N E M A 1 Indoor lP • Amps {u�aw;,., Cat. No. 2-Pole 2-Wire 30 60 1 00 200 400 600 ca • Fusible Systems �� 2-Pole 3-Wire S N CD 30 60 1 00 200 400 600 tri • • GFN422N With Neutra l , 1 20 Volts Ac (1 B l ade, 1 Fuse) ��� lec • Embossed metal nameplate permanently identifies cat. no., amps. h p ratings Front-operated h a n d l e permits close ganging. H a n d l e is i nteg ral part of switchi ng mech a n i sm ; provides permanent control of contacts; can be pad locked in O F F or ON position Red vi nyl cover i n stantly ide ntifies h a n die; i nd icates position B l ades visible i n open o r closed position Twin rei nforced b l ades provide maximum surface contact Qui ck-make, q u i ck-break, tease-proof switch i n g mecha n i sm Diamond-poi nted brea k jaws p ro l ong blade l ife ; keep si lver-plated contact a rea free of pitting a n d burn i ng Tin p l ated current carrying pa rts provide an exce l lent beari ng su rface for moving parts .E • GFN32 1 N NEMA 1 Plug Fuse Indoor, NEMA 3R Plug Fuse Rainproof Features-Specifications • ua ls General Duty Safety Switches Plug Fuse, Fusible and Non-Fusible 3-Pole 3-Wire ��� 3·Pole 4-Wire S N CD I<�� 30 60 1 00 200 400 600 30 60 1 00 200 400 600 GFN221 ® Approx. Wt. Lbs. 5 N E MA 3 R R a i n p roof 10 { w;,. 5 12 27 40 1 63 1 73 GFN42 1 N GFN422N GFN423N GFN424N GFN425N GFN426N r� Approx. Wt. Lbs. Std. Pkg. 6 5 1 V2 6 14 27 42 1 63 175 5 1 V2 3 7 V, 15 RGFN221 ® 10 RGFN321 N RGFN322N RGFN323N RGFN324N RGFN325N RGFN326N l w;,., "" "" . 3 Pole Solid Neutral Listings Below GFN325@ Use 3P, 4W Switch Cat. No. Max. Ac Std. 1 !11 1 !11 3!11 3!11 3 2 Pole Solid Neutral Listings Below 2 Pole Solid Neutral Listings Below GFN321N GFN322N GFN323N GFN324N GFN325N GFN326N r�· w;ffl Std. Pkg. Horsepower Ratings 240 VAC 1 60 5 13 27 42 1 63 173 10 1 1 1 1 1 { 3 7 V, 15 25 50 75 3 10 15 7 112 15 30 50 1 00 1 00 • 3 Pole Solid Neutral Listings Below RGFN325@ RGFN326@ 1 62 172 RGFN42 1 N RGFN422N RGFN423N RGFN424N RGFN425N RGFN426N 6 15 27 45 1 63 1 75 ��� 50 75 5 1 1 1 1 1 00 1 00 3 7% 15 25 50 75 .. 7 V, 15 30 50 1 00 1 00 Non-Fusible, 240 Volts A c - NEMA 1 a n d 3R Enclosures 2-Pole 2-Wire n 3-Pole 3-Wire nr 30 60 1 00 200 400 600 30 60 1 00 200 400 600 3 Pole Listings Below G UN321 GU N322 G U N323 G U N324 GUN325@ GUN326@ 5 12 24 42 1 36 1 46 10 1 1 1 1 1 RGUN221 N222 6 12 5 1 6 13 27 5 1 1 3 10 �. 3 Pole Listings Below RGUN321 RGU N322 RGU N323 RGU N324 RGUN325@ RGUN326@ 45 1 36 1 48 1 1 1 7 V, 15 30 50 1 00 1 00 n,..+ nh.o.. 1 QQ 1 .c om Cata log 30-150 Page 5 General Duty Safety Switches Di mens i onal Data, N E MA 1 , N E MA 3R NEMA 1 Plug Fuse Indoor, NEMA 3R Fuse Rainproof PF Plug Fuse Switches, RPF Plug Fuse Switches Amps 1, 2 30 N EM A 1 1, 2 0 0 D A tM c- � 4% B c D �:) D lP A 30 N E M A 3R 7 3/32 415/1 6 4 9% 35fs 6111 6 GFN Fusible Switches, GUN Non-Fusible Switches ar :c-- o --- � ..,_--- 8 --- rF:B NEMA 3R Rainproof NEMA 1 General Duty Indoor 61V1 6 an 0 NEMA 1 Indoor Dimensions - I nches A ua ls Poles ca E Poles 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 Amps Dimensions - Inches A 30 ·��--" 60 B 71 3/1 6 7V32 1 6 1/2 8% c 4111 6 55fs D 515/1 6 87/s E F 1 51/s 5 1 00 221511 6 1 0'/s 71/2 1 27/1 6 2 P/1 6 Fus 400 56'132 23112 1 21 1/32 1 7 3/4 462 9/32 17 441%2 23V2 1 2 1 V32 1 7% 371 3/32 17 200 3 1 '132 & 600 Non-Fus 400 & 600 1 3'/s 82 V32 1 3 2 1132 6 - ---- 291'132 8% For 60-600 Ampere Switches tri For 30 Ampere Switches Only lec NEMA 3R General Duty Rainproof(]) .E w For 30 Ampere Switches Only ww Note: Mou nting hole dimensions for NEMA 1 a n d 3R Switches a re as fo l l ows : 30 and 60A - %2' Dia. 1 00 and 200A - 1 %2 ' D i a . 400 and 600A - 1 7/32' D i a . Extern a l mounting fla nges a re n o t provided o n 400 and 600A switches. These switches have (4) i nternal mo u nt i n g ho les. October 1991 Poles 30 2, 3 1 00 2, 3 2, 3 2, 3 For 60 thru 600 Ampere Switches Amps 2, 3 2, 3 A j_ RGFN Fusible Switches, RGUN Non-Fusible Switches 60 Dimensions - Inches 8 A 9 1 V32 7 1 67116 97132 2215/1 6 1 1 1/s 1 4311 6 c 41/s 55fs 77/1 6 82 1/32 200 3 1 "132 561/s 231/2 1 2'/s Non-Fus 400 & 600 445fs 23V2 1 2% Fus 400 & 600 E F --- D 6 8112 1 5'/s 5 1 27116 2 1 '132 1 7 3/4 46 29132 17 17% 371 3/32 17 1 3 2 1132 6 3 2917132 8 /s ------ UL Listed Short-Circuit-Current Ratings General Duty Switches Switch Type Ampere Rating S h o rt-Circuit Rating Fusible Fusible 30-600A 30-600A 1 0,000A with H or K Fuses 1 OO,OOOA with R Fuses P l u g -Fuse Non-Fusible 30 30-600A 1 0,000A 1 0,000A withstand rating CD 30-200A outdoor switches have a provision for a raintight hub in the top end. All products in this catalog meet the wire bending space requirements as identified in 1 990 NEC Section 373-6 (b). .c om Cata log 30-150 Page 6 Heavy Duty Safety Switches Fu sibl e and Non-Fu s ible - J' ,.. . I 240 Volts Ac, 250 Volts De, FusibleCD NEMA 1 , 3R, 4/4X and 12 Enclosures Features-Specifications Line termi n a l s h ield p revents accidental contact with l i ne termi n a l s • De-ion a rc chute i nterrupts and cools hot a rcs; prevents a rc damage • Embossed metal nameplate permanently identifies cata log n umber, amperes a n d horsepower rat i n g • Red vinyl cover i n stantly identifies h a n ­ d le, i n d i cates position (down f o r "OFF," u p for "ON"). B l ades visible i n open o r closed position Quick-make, q u i ck-break, tease-proof switc h i n g mechanism • D i amo nd-poi nted brea k jaws p ro l o n g b l a d e life; keep contact a rea free o f pit­ ting and b u r n i n g • Tin-plated current-ca rryi n g pa rts have l u b ricated moving pa rts for ease of operation Easily accessible fuse h o lders su itable for stand ard, time delay and Type J fuses (Type J for 30-600A, 600V switches) Ample knockouts and wiring room w • L i ne and load termi n a l s s u itable for cop­ per or a l um i n u m wi re ww • ! }t l ---- -- ----- --- -- -- -- --- } gg { �gg 30 1 200 400 HFN221 HFN222 HFN223 HFN224 HFN225 HFN226 For NEC terminal data see page 9. For price information see Price List 30-125. For renewal parts data see Price List 30-1 90. WHFN221 WHFN222 WHFN223 RHFN221 RHFN222 RHFN223 RHFN224 RHFN225 RHFN226 1 200 JHFN221 JHFN222 JHFN223 JHFN224 Order 3 Pole switch below Order 3 Pole switch below Order 2 Pole switch from above Select neutral kit from neutral table on page 9 Order 2 Pole switch from above Select neutral kit from neutral table on page 9 Order 2 Pole switch from above Select neutral kit from neutral table on page 9 Fusible CD , 240 Volts Ac Horsepower Rating 30 60 1 00 200 400 600 800 (<) 1 20 0 (<) 3-Pole 3-Wire ��� HFN321 HFN322 HFN323 HFN324 HFN325 HFN326 HFN327 HFN328 3-PoleC�) 4-Wire SN 30 60 1 00 200 400 600 800 1 200 -- 4-Pole 4-Wire 30 60 · . RHFN321 RHFN322 RHFN323 RHFN324 RHFN325 RHFN326 RHFN327 RHFN328 -- Ac Std.® M a x i m u m (!:) 10 10 30 3 71/2 15 WHFN321 WHFN322 WHFN323 WHFN324 WHFN325 WHFN326 --· .-- 5 10 20 40 50 -- -5 10 20 40 3 10 15 --· -· 3 JHFN321 JHFN322 JHFN323 JHFN324 JHFN325 JHFN326 -- 7112 15 30 60 1 25 200 7 1f2 15 25 50 75 ·-- 3 switch from switch from above above Select neutral Select neutral kit from kit from neutral table neutral table o n page 9 on page 9 --- --- ·-- switch from above Select neutral kit from neutral table on page 9 -- HFN421 HFN422 15 25 50 75 --· -- --- -- 3 JHFN421 JHFN422 7112 -- · 600 Volts Ac, 600 Volts De, FusibleCD NEMA 1, 3R, 4/4X and 12 Enclosures Fusib leCD , 600 Volts Ac, 600 Volts De Poles Amps NEMA 1 ® Indoor Cat. No. N E M A 3R Rain proof Cat. No. NEMA 4/4X Stls. Steel Cat. N o . NEMA 1 2 Cat. No. -- 2-Pole 2-Wire 30 60 1 00 200 400 600 800® 1 200® HFN261 HFN262 HFN263 HFN264 RHFN261 RHFN262 RHFN263 RHFN264 WHFN261 WHFN262 WHFN263 Order 3 Pole switch below Fusible CD, 600 Volts, Ac ® 3-Pole 3-Wire r ��� 30 60 1 00 200 400 600 800® 1 200® JHFN261 JHFN262 JHFN263 HFN361 HFN362 HFN363 HFN364 HFN365 HFN366 HFN367 HFN368 WHFN361 WHFN362 WHFN363 WHFN364 WHFN365 WHFN366 CD Fo Class R fuse kits, refer to page 9 to order. ® 800 and 1 200 ampere switches have provision for Class L fuses. 0 Switches are available with provision for tang terminals. To order, add suffix A to catalog number. @ Ac rated only. 480V 10 - 600V 10 · 3 5 10 25 3 10 15 30 -- ·--- RHFN361 RHFN362 RHFN363 RHFN364 RHFN365 RHFN366 RHFN367 RHFN368 Horsepower Rating A c Std . ® JHFN361 JHFN362 JH FN363 JHFN364 JHFN365 JHFN366 -- 600V 30 5 15 25 50 1 00 1 50 15 30 60 125 200 7 112 Volts Maximum (f) 480V 600V 10 10 -- -7'12 20 30 50 -- 480V 30 -- ------50 15 7 112 --· 50 7112 15 30 60 125 200 7 lf2 switch from above Select neutral kit from neutral table on page 9 De 30 3 10 15 1 112 Order 2 Pole switch from above Select neutral kit from neutral table on page 9 -- 250 Volts 240 Volts -- --r"--. , ., . f"" , .,,. --�.--, ., . !""·· ,,. Jt l ---k�< ----- -���� ------------- -- �� ------- .E lec • • 2-PoleC�) 3-Wire SN N E MA 1 2 (31 Cat. N o . N E MA 4 4X Stls. Steel Cat. No. N E M A 3 R <?; Rain proof Cat. No. N E MA 1 :IJ Indoor Cat. N o . ca • Front-operated h a n d l e permits close g a n g i n g . H a n d l e is i nteg ral p a rt of switch­ ing mech a n i s m ; provides permanent con­ trol of contacts; can be padl ocked i n OFF o r ON position 30 60 1 00 200 400 600 800@ 1 200@ tri • 2-Pole 2-Wire an Dual cover i nterlock prevents accidenta l operati o n ; door cannot be opened when switch is ON; contacts can not close with door open. Both functions are defeatible by authorized person nel Amps tM • Fusible CD , 240 Volts Ac or 250 Volts De Poles ar • Bonderized UL Li sted organic finish resists rust lP • ua ls - 480V 30 -- 15 30 60 1 25 250 400 De 250 600 10 25 40 50 ---- 10 25 40 50 600V 30 20 50 75 1 50 350 500 10 25 40 60 50 @ For all neutral kits refer to page 9 to order. @ Applies when standard, Class H fuses are used. 0 Applies when time delay fuses are used. ® These 800 and 1 200A switches are rated 250V De max. (9) 30-400A switches are also rated 600V De. October 1 991 .c om Cata log 30-150 Page 7 240, 480, 600 Volts Ac, 250, 600 Volts De, FusibleG:l and Non-Fusible NEMA 1, 3R, 4/4X and 1 2 Enclosures • • Amps Door i nterlock p revents door from open­ i n g when switch is energ ized Star mo u nting feet assure easy mounting . ,. . , . r . . . , . r· · ,. . , . r·· · ,. . , . J� Fusible G), 600 Volts Ac Poles 3-Pole 4-Wire S N ® I <<< 30 60 1 00 200 400 600 800 1 200 NEMA 1 @ Indoor Cat. No. o... • CSA Certified File (400- 1 200 amps) LR-281 1 5 Fusible, 600 Volts Ac • Meets NEMA Spec. KS 1 - 1 990 4-Pole 4-Wire • Meets Federal Spec. WS-865c, Type H D • • 2-Pole@ 2-Wire ca I( �g 1 200 400 600 Al l switches a re U nderwriters' Laborato­ ries l i sted and su ita ble for use as Service Entrance E q u i pment when neutral i s pro­ vided o r g rou n d i n g kit is empl oyed . All Heavy Duty Safety Switches, when used with Cl ass R o r J fuses, a re rated for 1 00,000 amps RMS ava i l a ble. l't ratings assure that the let-t h ro u g h peak currents will a l ways be with i n the switches i nterrupti n g capa b i l ity. When used with Class R o r J fuses, these with­ stand ratings a re as fo l l ows : IP ( Pea k Amperes) l' t (Amps' Seconds) 1 1 ,000 2 1 ,000 25,000 40,000 60,000 80,000 50,000 200,000 500,000 1 ,600,000 5,000,000 1 0,000,000 .E Switch Ampere Rati n g ww w 30 60 1 00 200 400 600 For NEC terminal data see page 9. For price information see Price List 30-125. For renewal parts data see Price List 30-190. October 1991 { { -:-- us e 3 Pol e below -- Us e 3 Pole below rn 30 60 1 00 200 400 600 NEMA 1 2 �J Cat. No. sw itch es f rom pag e 6 and s el ect neutral ki t f rom pag e 9 swi tch es f r om pag e 6 and s el ec t neut ral kit f r om pag e 9 HUN321 HUN322 HUN323 HUN324 HUN325 HUN326 { Us e 3 Pole bel ow ------ No n-Fusib le, 240 Volts Ac 3-Pole 3-Wire NEMA 414X Stls. Steel Cat. No. · HFN461 HFN462 lP 30 60 Non-Fusible, 240 Volts Ac - tri • Provide depen dable conti nuous service on the most rugged industrial appl ications. lec • ... ar UL Listed File E5 1 89 and complies with UL Sta ndard UL98 �<<� NEMA 3 R 0 Rainproof Cat. No. swi tch es f rom swi tch es f rom pag e 6 and pag e 6 and s el ect neutral s el ect n eu t ral kit f rom kit f rom pag e 9 pag e 9 • Application Data an Door latch securely holds door closed; permits padlocking tM Features-Specifications • ua ls Heavy Duty Safety Switches Fu s i ble a n d Non -Fu sible RHUN321 RHUN322 RHUN323 RHUN324 RHUN325 RHUN326 { n 30 60 1 00 200 400 600 800 1 200 HUN261 HUN262 RHUN261 RHUN262 ((( 30 60 1 00 200 400 600® 800® 1 200® WHUN321 WHUN322 WHUN323 JHUN321 JHUN322 JHUN323 WHUN261 WHUN262 JHUN261 JHU N262 nn 30 60 1 00 200 71/2 15 30 60 1 25 200 15 30 60 1 25 250 400 De 600V 250V 600V 30 20 50 75 1 50 350 500 480V 600V 480V 20 20 30 600V 30 25 50 15 30 20 50 480V 20 600V 20 240V 240V 480V 10 30 10 600V 30 3 10 15 15 7'12 15 30 60 1 00 200 240V 240V 480V 10 10 10 6DOV 10 ------=7112 =----=1-=o 15 20 25 30 O rder 3 Pole sw i tch bel ow 240V 10 HUN361 HU N362 HUN363 HUN364 HUN365 HUN366 HUN367 HU N368 RHUN361 RHU N362 RHU N363 RHUN364 RHUN365 RHUN366 RHUN367 RHU N368 240V 480V 10 30 20 50 75 1 25 250 400 JHUN361 JHUN362 JHUN363 JHU N364 JHU N365 JHU N366 WHUN361 WHUN362 WHUN363 WHUN364 WHUN365 WHUN366 60DV 30 20 50 75 1 50 350 500 50 15 30 50 50 --- --- Non-Fusib le, 600 Volts Ac, 250 Volts De 4-Pole 4-Wire 5 , Volts Maxi m u m (Z) 48DV 600V 48DV 30 30 30 25 50 1 DO 1 50 --- --- Us e 3 Pole bel ow Non-Fusib le, 600 Volts Ac ® 3-Pole 3-Wire Ae Std . ® 480V 600V 20 20 Non-Fusible, 600 Volts Ac, 600 Volts De 2-Pole 2-Wire Horsepower Rating JHUN461 JHU N462 HUN461 HUN462 HUN463 240V 600V 48DV 20 30 20 600V 30 25 50 50 30 60 75 10 20 30 20 50 60 5 10 20 ----- --- - (1) For Class R fuse kits, refer to page 9 to order. @ 800 and 1 200 ampere switches have provision for @l Class L fuses. (3'; Switches are available with provis-Ion for tang terminals. To order, add suffix A to catalog number. ,:6l 0 �� For a l l neutral kits refer to page 9 to order. Rated 250V De max. Applies when standard, Class H fuses are used. Applies when time delay fuses are used. 30-400A switches are also rated 600V De .c om Catalog 30-150 Page 8 Heavy Duty Safety Switches Dimensional Data NEMA 1 Indoor 8 A For 30A, 600V and 60 t h ro u g h 1 200 Ampere Switches c D 2 50/600 Volt H F N Fusible Switches For 30 Ampere, 250V Switches -r I 3(]) 3 3 (]) 3 3 3 3 3 3 3 7112 9 9 9 1 Q 1 3f1 6 1 3 1 3f1 6 99!32 19 1 67/1 6 19 287/1 6 375AJ 563!32 30 30 60 60 10 0 200 400 600 BOO 1200 23112 23112 563!32 663/4 7J15f1 6 403AJ 433AJ 4131.32 5 1 1f1 6 627!32 33/4 9'AJ 9'AJ 1 2'14 13 "!32 1 77/1 6 1 77/1 6 6 B3AJ 17 17 511f1 6 511f1 6 7112 B2 1!J2 1 2 , ,1.32 1 2 1 11.32 1 2 '14 1 2 '14 23"!32 357Al 4629!J2 4629!J2 561 1!32 63 17!32 3 1 112 34112 1 7112 17112 2 50/600 Volt H U N Non-Fusible Switches NEMA 3R Rainproof 3(]) 3 3 3 3 3 3 3 3 Poles 403AJ 433AJ Amps 4131.32 5 1 1/1 6 5 1 1f1 6 7112 82 1;32 1 2 , ,132 1 2 1 1)32 3'14 5 5 6 6"!32 9'AJ 97Al 1 2 '14 13 "!32 17711 6 177/1 6 1 7 112 1 7 112 12 ,/4 1 2 1/4 8 c 2, 3Ci) 30 2, 3 30 2, 3 60 2, 3 10 0 200 2, 3 400 2, 3 2, 3 600 BOO 2, 3 1200 2, 3 1 03/1 6 19 19 287/1 6 7 112 g1;4 g1;4 1 1 3/1 6 143/1 6 413f1 6 75/1 6 55AJ 55AJ 7112 37% 561AJ 23112 561AJ 23112 403AJ 663/4 7315/1 6 433AJ lP ca tri For 30A, 600V and 60 through 200 Ampere Switches w .E lec For 30 Ampere, 250V Switches Note: Mtg. hole sizes for N E M A 1 , 3R, 4/4X a n d 1 2 switches are a s follows: 30 & 60 A - 9/32'' Dia. 1 00 & 200A - 1 1/32" D i a . 400- 1 200A - 1 7/32"Dia. 400-1 200A NEMA 1 & 3R switches have internal mounting holes ( m o u nt­ ing feet not provided). Poles 1 03/1 6 19 19 287/1 6 375AJ 445AJ 445AJ 6029!J2 7112 9'14 9'14 1 1 3/1 6 143/1 6 23 112 23112 403AJ 6511f1 6 433)8 1J2, 3f4, 112, 3!4, 112, 3!4, 112, 3;4, 112, 3;4, 112, 314, 1 1 ' 1 '14, 1 , 1 '14, 1' 1 1/4, 1 , 1 114, 1 112, 2, 2 112, 3, 3112, 4 2112, 3, 3112, 4 9112 9112 1 2 '14 83/4 1 3112 1 23AJ 1 7 112 123AJ 1 7 112 129132 17112 129!32 17112 413f1 6 75/1 6 55AJ 9112 9112 55AJ 7112 1 2 '14 83/4 1 3112 123AJ 1 7 112 1 23AJ 1 7 112 1 29!32 1 7 112 1 29!32 1 7 112 37131.32 50112 559!32 6112 112, 314. 112, 314. 112, 3/4, 26"!32 112, 3/4, 3529!J2 112, 3/4, 4629!J2 2112, 3, 4629!J2 2112, 3, 561 1!32 6317!32 33/4 5 5 6 B3AJ 1] 5AJ 175AJ 17 17 31 112 34112 6112 33/4 5 5 6 83AJ 17 17 1]5AJ 1] 5AJ 26"!32 3529!J2 37"!32 37"!32 50112 3 1 112 34112 112, 3f4, 112, 3;4, 112, 3/4, 112, 314. 112, 314. 2112, 3, 2112, 3, 8 15 14 1 112, 2, 2112 1 112, 2, 2112 1 112, 2, 2112 17 1 112, 2 2112, 3 38 61 163 173 510 570 1f.2, 3J4, 1 7 14 112, 3;4, 1 ' 1 '14, 1 112, 2, 2112 14 112, 3;4, 1' 1 '14, 1 112, 2, 2112 1f.2, 3f4, 1 1f4, 1 112, 2 34 58 112, 3/4, 1 112, 2, 2112, 3 1 36 2112, 3, 3112, 4 2112, 3, 3112, 4 146 466 517 1 ' 1 '14, 1 ' 1 '14, 1 , 1 '14, 1' 1 '14, 1 112, 2, 3112, 4 3112, 4 1' 1 1f4, 1, 1 1f4, 1 , 1 '14, 1' 1 '14, 1 112, 2, 3112, 4 3112, 4 Approx. Weight Lbs. Hub Sizes )nches Conduit Sizes, Inches D 2 50/600 Volt R H U N Non-Fusible Switches NEMA 4/4X Watertight Stainless Steel. NEMA 12 Dust-Tight and Oil-Tight Industrial 23"!32 357Al 3713)32 3 1 112 34112 2 50/600 Volt R H F N Fusi ble Switches 30 2, 3Q) 2, 3 30 2, 3 60 2, 3 100 2, 3 200 2, 3 400 2, 3 600 BOO 2, 3 1200 2, 3 631132 1 5 1AJ 151AJ 83Al 17 17 Dimensions - Inches ar For 30 Ampere, 250V Switches 1 0 1 3/1 6 1313/1 6 23112 23112 651111 6 A For 30A, 600V a n d 60 through 1 200 Ampere Switches 7112 9 9 99!32 1 6112 1 6112 287/1 6 375AJ 4419132 44191.32 6Q29J.32 30 30 60 100 200 400 600 BOO 1 200 an 2, 2, 2, 2, 2, 2, 2, 2, 2, tM A ww 631!J2 175AJ 1 51Al 1] 5AJ 5 5 5 9'Al ua ls 2, 2, 2, 2, 2, 2, 2, 2, 2, 2, Approx. Weight Lbs. Conduit Sizes, Inches Dimensions - Inches Amps Poles 1 112, 2 3f4, 1 112, 2 3f4, 1 112, 2 3f4, 1 112, 2 3f4, 1, 1, 1' 1, 1 1!4, 1 1!4, 1 1/4, 1 1f4, 2112, 3 2, 2112, 3 1 1/2, 1 112, 1 112, 1 112, 2 10 2 18 2 19 2 39 63 163 173 485 590 2 3f4, 1, 1 1!4, 1 112, 2 2 3;4, 1' 1 '14, 1 11.>, 2 2 3;4, 1, 1 1f4, 1 112, 2 2 3f4, 1, 1 1!4, 1 112, 2 2112, 3 2, 2112, 3 1 112, 1 112, 1 112, 1 112, 559!32 10 17 17 39 60 136 146 480 580 - ---Amps Dimensions - Inches A 8 c 2 50/600 Volt WHFN Fusible Switches 2, 3 Ql 2, 3 30 30 60 2, 3 1 00 2, 3 2, 3 200 2, 3 400 600 2, 3 -------- - 1( ) 1 1/1 6 19 19 287/1 6 375/s 583/1 6 583/1 6 J15J1 6 971:32 9'132 1 1 '/1 6 1 43/1 6 2 31/2 2 31/2 421i:32 5 1 7132 5 1 7132 7 1/2 83/4 1 2 1/4 1 2 1/4 D 7 3/1 6 E --- ------ F Approx. Weight Lbs. 9 19 19 37 64 1 63 173 99/1 6 99/1 6 1 2 '14 1 3 112 1 7 5/s 1 7 5fs 4 5 5 6 8% 18 18 26"132 35 29/32 573/1 6 573/1 6 73/1 6 99/1 6 99/1 6 1 2 '14 1 3 112 1 7 5/s 1 7 5fs 4 5 5 6 8318 18 18 1 01/1 6 1 7 5/s 1 7 5/s 262 3/32 35 29/32 4 5 1 1/1 6 4 5 1 1/1 6 -]i;, 9'11 6 99/1 6 1 2 '14 1 3 112 1 7 5fs 1 7 5/s 4 5 5 6 83/s 18 18 1 31/1 6 1 7 5/s 1 7 5/s 2 623132 3 529/32 57'11 6 573/1 6 10 18 18 40 62 1 63 1 73 7 1/s 99/1 6 99/1 6 1 2 1/4 1 3 112 1 7 5/s 1 7 5fs 4 5 5 6 8% 18 18 1 31/1 6 1 7 5fs 1 7 5fs 26"132 352 9132 45 1 1/1 6 45 1 1/1 6 -----10 17 18 39 60 1 36 1 45 1 0 1J1 6 1 7 5fs 1 7518 250/600 Volt W H U N N o n-Fusible Switches 2, 3 G:: 2, 3 3 3 3 3 3 30 30 60 1 00 200 400 600 1 01 1/1 6 19 19 287/1 6 375/s 4611/1 6 46 1 1/1 6 715/1 6 9'132 97/32 1 1 '11 6 1 4'11 6 231/2 231/2 42 11:32 5 1 7132 5 1 7/32 7112 83/4 1 2 1/4 1 2 1/4 9 17 18 36 56 1 36 1 45 ----- 250/600 Volt J H F N Fusible Switches 2, 2, 2, 2, 2, 2, 2, 3CD 3 3 3 3 3 3 30 30 60 1 00 200 400 600 1 31 1/1 6 19 19 287/1 6 375fs 583/1 6 583/1 6 7 2 9!32 9'132 971:32 1 1 '11 6 1 43/1 6 23112 2 31/2 42 11:32 5 1 7132 5 1 7/32 7112 83/4 1 21/4 1 2 1/4 2 50/600 Volt J H U N Non-Fusible Switches 2, 3 Q; 2, 3 3 3 3 3 3 30 30 60 1 00 200 400 600 1 3 1 1/1 6 19 19 287/1 6 37518 4611/1 6 4611/1 6 7 29!32 97/32 97/32 1 1 3/1 6 1 43/1 6 231/2 23112 42 1/32 5 1 7132 5 1 7132 7 '12 83/4 1 2 1/4 1 2 '14 (!) 250 Volts only All products i n this catalog meet the new wire bending space requirements as identified in 1 990 NEC Section 373-6 (b). October 1 991 .c om Catalog 30-150 Page 9 General and Heavy Duty Safety Switches Modifications and Accessories Terminal Data For Switches That Comply With 1 990 NEC Sect. 373-6 (b) Heavy Duty Plug - General Duty Double Throw Amps No. M i n . of Wire wires Size Max. Wire Size Amps No. M i n . Type Wire of 60!75°C wires Size 30 60 1 00 200 400 or 600 #8 #3 110 250 750 300 500 Cu CuiAI CuiAI CuiAI Cu Cu CuiAI MCM MCM MCM MCM 30CD 30® 60 1 00 200 400 or 600 800 1 200 1 1 1 1 1 1 2 2 3 4 #14 #14 #14 #14 #6 250 MCM 3/0 1/0 110 110 Type Amps No. Min. of 60/75°C Wire wires Size #8 #3 #3 110 250 750 300 500 750 750 CuiAI CuiAI CuiAI CuiAI CuiAI CuiAI CuiAI Cu/AI CuiAI CuiAI 1 1 1 1 2 30 60 1 00 200 400 or 600 800 #14 #14 #12 #6 110 #2 110 250 MCM ua ls #14 #14 #14 #4 250 MCM 310 110 1 1 1 1 1 2 2 Max. Wire Size MCM MCM MCM MCM MCM MCM 1 2 3 Max. Type Wire Size 60/75°C #6 #2 110 250 300 750 350 500 MCM MCM MCM MCM MCM CuiAI CuiAI CuiAI CuiAI CuiAI CuiAI CuiAI CuiAI Electrical Interlock Kits for 2 and 3 Pole Heavy Duty Safety Switches an E l ectrical i nterlock kits a re ava i l a b l e for 2 a n d 3 pole Heavy Duty Safety Switches. Al l a re Field i n sta l l a b l e in N E MA 1 , 3R, 4/4X and 1 2 switches a n d provide 2 NO and 2 NC contacts. They a re mou nted on a steel bracket and are actuated by the switch mechanism. All con­ trol contacts operate before the safety switch b l ades open or close. EK5 Kit Ampere Ratings Kit Catalog 1 20VAC 240VAC 480VAC 1 25VDC 250VDC N u m ber Safety Switch Rating 10 15 15 15 20 20 10 15 15 15 20 20 tM EK-1 30A-240V 30A-600V, 60A-240 & 600V EK-2 1 00A EK-31 EK-32 200A EK-4 800 & 1 200A EK-5 400 & 600A �� �� ft'c � �� " \r RFK1 Switch Type and Neutral Kit Cat. No. and Wire Range General 2 a n d 3 Neutral Kit Wire Range Pole Duty Heavy Duty 60175°C Cu/AI 30A, 250V 30A, 600V ­ a n d 60A 1 00 200 400 N K400 ( 1 ) # 1 4-6 ( 1 ) # 1 4-2 N K 1 00 NK200 N K400 ( 1 ) # 1 4- 1 /0 ( 1 ) #6-250 MCM ( 1 ) #4-750 MCM or 2 1 /0-250 M C M (2) #4-500 MCM (3) 1 /0-750 MCM (4) 1 /0-750 MCM NK600 NK800 N K 1 200 Description lec .E RFK5 II 0 w ww '14 '14 Wire Range 60/75°C Cu/AI G N K6 G N K20 G N K60 # 1 4-6 # 1 4-2 #6- 1 /0 Amps 30A, 250V 30A, 600V/60A, 250V 60A, 600V 1 00/200A, 250/600V 400/600A, 250/600V Cat. No. RFK1 RFK2 RFK3 RFK4 RFK5 For use with N E MA 3R General Duty, Heavy Duty, Double Throw a n d 6 Pole Motor Circuit Switches Description All 400 and l a rger rainproof switches are s h i pped with p l a i n tops, no cutouts. Myers-Type Hubs@ Description For use i n special applications. ST2 '12 '12 Interchangeable Rainproof Hubs R1 H200 ROH100 October 1 991 For use with Genera l a n d 2 a n d 3 pole Heavy Duty safety switches only. Kit w i l l reject a l l fuses except class R. Only one kit req u i red for a three pole switch. All rain proof switches 30-200 a mperes are shipped with cutout covered by a p l ate. H u bs smaller than 2" can be used on 200 a mpere switches by ordering an a d a pter plate R 1 HA. R 1 HA 2 2 Catalog N u m ber 60A 200A 600A tri N K600 N K30 NK60 Max. Sw. Rating Class R Fuse Clip Kits RFK3 1 1 '14 '14 '14 For General Duty a n d 2 a n d 3 Pole Heavy Duty Switches Switch Ampere Rating 600 800 1 200 RFK2 ''" ''" ''" Equipment Grounding Kits ca GNK20 .15 .25 .25 .25 .25 .25 General Duty a n d 2 a n d 3 Pole Heavy Duty ar NK600 .3 .5 .5 .5 .5 .5 1 20VAC 240VAC 1 25VDC 250VDC Neutral Kits - Field Installed lP GNK6 15 15 15 20 20 Kit Horsepower Ratings CD 250V Switch @ 600V Switch 0 M i nimum order; 1 Std. Pkg. or contact local distributor. Hub Dia. Inches % 1 1 V. 1 V2 2 Switch Size 30 thru 1 00 Amps 2 2112 3 Adapt� Plate 200 Amps Hub Dia. Inches Zinc Cat. No. % ST2 Cat. No. ROH075 ROH100 ROH125 ROH150 ROH200 R1 H200 R1 H250 R1 H300 R 1 HA Std. Pkg. Oty. 25 For price informetion see Price List 30-125. .c om Catalog 30-150 Page 1 0 NEMA 1 30, 60, 100 Ampere Switch XUK362 I ua ls Motor Circuit Switches Double Throw Switches SDSN6030 Double Throw Switches Double Throw Safety Switches - 240V AC - 250V DC Features - Specifications 'o' " • • Application Data Double th row switches a re supplied from the factory to switch from a normal to an alternate power source. They can be field converted to switch from a normal to an a lternate load from a s i n g l e power source. NEMA 3 R Fusible o 6 61 • • • • I Amps an - - XUK321 XUK322 XUK323 XUK324 XUK325 XUK326 X U K327 1 - 33 33 33 74 1 28 175 175 Use 600V Switch Cat. No. NEMA 1 sss I I I 1 30 60 1 00 200 4oo NEMA 3R Approx. Wt. Lbs. 10 30 3 7112 15 25 50 75 3 10 15 - 7112 15 30 60 125 5 10 20 40 50 50 - 15 - 10 20 40 5 10 20 40 50 50 50 - 3 10 - 1 25 1 25 1 25 Horsepower Ratings AC Max. AC Std. 240V 31'! 480V 30 600V 30 240V 30 480V 31'! 600V 30 Desig ned to meet the demands of heavy i n d ustry for a compact, n o n-fu s i ble switch with visible contact d i sco n n ect. Provides a n i n-sight d i sco n nect for two speed, 3!21 motors which a re remote from their motor control devices. XFK361 ® XFK362® XFK363® XFK364® XFK365@ - 5 15 25 50 1 00 7112 15 30 60 1 25 7112 15 30 60 1 25(]) 15 30 60 1 25 250Ql 20 50 75 1 50 350Ql - - 10 20 40 60 1 25 1 25 1 25 20 50 75 1 25 250 250 250 30 60 1 00 1 50 350 350 350 - - 44 46 46 1 05 230 3 7112 15 25 50 RXUK361 RXUK362 RXUK363 RXUK364 RXUK365 RXUK366 RXUK367 33 34 34 78 140 1 75 1 75 - N o n-Fusi b l e - 3 Pole@ 3-Pole 3-Wire 30 60 1 00 200 400 600 800 tri Application Data • 1 112 3 7112 45 45 47 110 230 325 RXFK32 1 ® RXFK322® RXFK323® RXFK324® 30 Double Throw Safety Switches - 600V AC Poles I l l """""" Il l lec ww • .E • I n s u l ated shield prevents acci dental con­ tact with l i ne term i n a l s B l ades v i s i b l e i n o p e n o r closed position Cover i nterlock prevents cover from open­ ing when switch i s en ergized. Interlock release permits cover to be opened for switch i n spection. Trun k-type latches keep cover tig htly closed; provides a n effective d u st-resist­ i n g seal Over-center q u ick-make, q u ick-break switc h i n g mechanism prevents teas i n g of contacts Large wiring g utters fac i l itate wiring a n d provide easy access t o term i n a l s H a n d l e c a n b e padl ocked i n O F F pos ition by up to th ree pad locks Cover can be padlocked in closed positi o n Neoprene gasket sea ls o u t moist u re a n d d u st from switch assembly 6 Pole switches a re l i sted under U L E-5 1 89 Fusi ble u n its not ava i l a b l e w • XFK32 1 ® XFK322® XFK323® XFK324® XFK325® XFK326® 30 60 1 00 200 400 600 30 60 1 00 200 400 600 800 I"""""" ! I Ill sss Features - Specifications • I I I� 10 N o n-Fusi b l e - 3 Pole ( u se 3 pole for 2 pole appl icatio n s ) @ 3-Pole 3·Wire 3-Pole 3-Wire Typical Schematic "Double Th row" • �c· """' Max. Std. Fusi ble - 3 Pole ON Motor Circuit Switches • sss NEMA 1 Non-Fusible � OFF Yo N • ��� 3-Pole 3-Wire ca • I 250 Volts DC 240V AC Fusible - 3 Pole (use 3 pole for 2 pole appl ications) tM • ;;·��0; ,.,. Horsepower Rating ar • Cover i nterlock prevents door from open­ i n g when switch is energ ized Qui ck-make, q u ick-break operating mechanism H a n d l e may be padl ocked i n top O N , neu­ tra l , o r bottom O N positions All switches a re U L Listed under File No. E5239 and a re su ita ble for use as service entrance e q u i pment. All co m ply with Federal specifications W-S-865c Type N D D lP • XUK361 XUK362 XUK363 XUK364 XUK365 XUK366 XUK367 - - CD These rati ngs apply only when J fuse kit catalog num­ ber DJ400JK i s used. ® Rated 1 0,000 AIC max with Class H fuses or 1 00,000 AIC with Class R fuses and rejector kit. GJ Accepts 600V Class T fuses as standard and Class J fuses when used with kit no. DT400JK. Rated 1 00,000 AIC max. @) Rejector Kits Use with Double Throw Switches Only Electrical Interlock Kits for 4 Pole Heavy Duty and Double Throw Switches Kits reject a l l fuses except C l ass R; one kit req u i red per 3 pole switch. C l ass R fuses wi l l fit in switch without using a n "R" fuse kit. Switch Type and Rati n g I Catalog Description -,--___.-------,-ccV t --------1 Nu mber Am p e re s ol s 30 30 60 60 1 00 200 240 600 240 600 240/600 240/600 DS12FK DS16FK DS16FK DS26FK DS36FK DS46FK ® Rated 1 0 ,000 AIC max when protected by Class H fuses or 1 00,000 AIC max when protected by Class R, J or T fuses. Fuse ampere rating m u st not exceed switch ampere rati ng. Accepts 300V Class T fuses only. Rated 1 00,000 AIC max. Double Throw only 30-SOOA Double Throw 30SOOA a n d 30-200A 4 Pole I Contacts 1 N O (Control Pole) 1 NO 2 NO 1 NC 2 NC K i t Catalog N u mber DS16P DS200EK1 DS200EK2 "J" fuse kit (for Cat. N o . XFK365 o n ly) DT400J K For Price Information see Price List 30-125 Or.tnh�>r H l!l 1 .c om Catalog 30-150 Page 1 1 Double Throw Switches Motor Circuit Switches Dimensional Data Motor Circuit Switches Double Throw Neutral Kits ' Amps DT100NK DT200NK DSBOONK DT400NK (1) (1) (2) (2) DT600NK (2) 250-500 M C M - Motor Circuit Switches Terminals are Suitable for Either Copper or A l u m i n u m Cable 6 Pole N on-Fused Disconnect Complete Neutral Kit Wire Range 60/75'C Cu/AI # 1 4- 1 /0 #6-250 MCM #3/0-750 MCM #6-250 MCM 30 60 1 00 200 - Approx. Weight Lbs. Catalog Number NEMA 1 NEMA 3R NEMA 1 2 SDSN6030 RDSN6030 JDSN6030 SDSN6060 RDSN6060 JDSN6060 SDSN6100 RDSN6100 JDSN6100 SDSN6200 RDSN6200 JDSN6200 Maximum H P Ratings 600 VAC 250 VDC 30-100 Amps 200 Amps 400-800 Amps CD DT600NK may also be used in 400A Non-Fusible switches when wire size exceeds 250 MCM. I 240 VAC 1 10 Amps 1 20 VAC 480 VAC 600 VAC 30 60 1 00 200 5 10 15 20 40 75 1 00 25 60 75 1 00 ® 1 ' I 20 ' 30 6o I Switch Rating Wire Range Aluminum Copper ua ls 30-100 Amps 200A 400 & 600A Fusible CD400A NonFusible 600A Non-Fusible 800A Non-Fusible Neutral Kit Cat. No. 30 60 1 00 200 28 30 32 49 # 1 2-#2 # 1 2-#2 # 1 2-1/0 #4-300 MCM # 1 4-#2 # 1 4-#2 # 1 4- 1 /0 #4-300 MCM Auxiliary Switch Kits@ I 250 VDC Amp Rating Switch Used With I 7112 15 . 25 4o Contact Arrangement 30, 60, 1 00 200 200 1 Permits field mounting of an auxiliary switch for sepa­ rate control circuit applications. Each switch includes three soldered, identified leads. Kit Style No. 1 A, 1 B 1 A, 1 B 2A's, 2B's an Switch Type and Ampere Rating 1 78C265G05 178C619G01 178C619G02 tM Double Throw Safety Switches - N E MA 1 I ndoor, N E MA 3R Outdoor Not to be used for construction purposes unless approved. For additional d i m ensions, refer to the Distribution Service Center. Fusible Switches Catalog Number XFK322 XFK323 XFK324 ON I XFK326 XFK361 ON XFK362 XFK363 XFK364 C D --I Catalog Number 37 37 37 5 1 318 743f4 861/s 1 1 1 '11 6 97/s 1 1 1 5f1 6 9718 1 1 1 5f1 6 9718 1 99/1 6 1 1 '14 141/s 25'18 277/1 6 1 41/a 33112 9'14 33112 9'14 33112 9'14 47 16 69112 20 '14 803/4 22'14 1f2, %, 1, 1 114, 1 1/2, 2 112, 3f4, 1 ' 1 '14, 1 112, 2 112. %, 1, 1 '14, 1 112, 2 1 112, 2, 2112 No Knockouts No Knockouts 37 37 37 5 1 '18 74% 1 1 1 5/1 6 97/s 1 1 1 5/1 6 97/s 1 1 1 5f1 6 97/s 1 99/1 6 1 1 '14 1 4 1/s 253/s 33 '12 91/4 331/2 9'14 33112 9'14 47 16 691/2 20'14 112, 314, 1' 1 '14, 1 112, 2 112, %, 1 ' 1 '14, 1 112, 2 1f2, %, 1, 1 '14, 1 1/2, 2 1 1/2, 2, 21/2 No Knockouts 1 1 1 '11 6 911s 37 1 1 1 '11 6 97/s 37 37 1 1 1 '11 6 9718 5 1 3/s 1 99/1 6 1 1 '14 33112 9'14 331/2 9'14 331/2 9'14 47 16 112, 314, 112, %, 112, %, 1 112, 2, ca XFK365 ··) -- ._, r- E B lP OFF XFK325 A Non-Fusible Switches Conduit Sizes, Inches ar XFK321 Dimensions RXFK321 RXFK322 RXFK323 RXFK324 1, 1 '14, 1 112, 2 1, 1 '/4, 1 112, 2 1 , 1 1/4, 1 1/2, 2 21/2 XUK322 XUK323 XUK324 XUK325 XUK326 XUK327 XUK361 XUK362 XUK363 XUK364 XUK365 XUK366 XUK367 RXUK361 RXUK362 Note: (3) V4' Dia. mounting holes are provided on 30-1 OOA switches and (4) 9/1 5" Dia. mounting holes are provided on 200-800A switches. RXUK363 tri lec XUK321 RXUK364 RXL!K365 RXUK366 RXUK367 Dimensions Conduit Sizes, Inches A B C D E 25 25 25 377/s 54'14 63% 63% 1 1 1 5f1 6 1 1 1 5f1 6 1 1 1 5f1 6 1 99/1 6 231/s 24118 241/s 9718 97/s 9718 1 1 '14 1 2112 1 4118 14118 2 1 1/2 21 1/2 2 1 112 33112 49 58112 58112 9'14 9'14 9 '14 16 18 19 19 1f2, 314, 1, 1 '14, 1 112. 2 112, %, 1' 1 '14, 1 112, 2 112, %, 1' 1 '14, 1 112, 2 1 112. 2, 21/2 N o Knockouts N o Knockouts No Knockouts 25 25 25 377/s 54'14 63% 63% 1 1 1 5f1 6 1 1 1 5!1 6 1 1 1 5f16 199/1 6 231/a 241/a 241/s 97/s 97/s 9718 1 1 '14 1 2 112 1411s 141/s 2 1 112 2 1 1/2 2 1 1/2 331/2 49 58112 58112 9 '14 9'14 9'14 16 18 19 19 112, %, 1' 1 '14, 1 '12, 2 112, %, 1 , 1 '14, 1 1/2, 2 112, %, 1' 1 '14, 1 112, 2 1 '12, 2, 2112 No Knockouts N o Knockouts N o Knockouts 25 25 25 377/s 54'14 64 64 1 1 1 5f1 6 1 1 1 5f1 6 1 1 1 '11 6 1 99/1 6 23118 241/s 241/s 97/s 9718 9718 1 1 1/4 1 2 112 1 4'18 1 41/s 2 1 1/2 21 1/2 2 1 1/2 331/2 49 58112 581/2 9'14 9'14 9'14 16 18 19 19 112, 314, 1' 1 '14, 1 112, 2 112, %, 1' 1 '14, 1 112, 2 112, 314, 1' 1 '14, 1 112, 2 1 112, 2, 21/2 N o Knockouts N o Knockouts N o Knockouts Motor Circuit Switches - 6 Pole N on-Fused Discon nect Comp lete 6 Pole U n its - 30, 60, 1 00 a m peres .E w-n� �� � � ON OF ww w A 6 Pole U n its - 200 a m peres T[/!> lL r c ... =, [ � ��- g] lr 0 • • • I J A I 1T B -� . 6 Pole U n its - 30, 60, 1 00 Amperes Enclosure Type Dimensions - Inches and M M A ln. NEMA 1 NEMA 3R NEMA 1 2 1 8% 1 8% 1 8% MM 476 476 476 B ln. 3 1 7/1 6 3 1 7/1 6 3 1 7/1 6 799 799 799 ln. MM 470 470 470 81511 6 815/1 6 815/1 6 227 227 227 2 1 7/1 6 2 1 7/16 2 1 711 6 545 545 545 9% 9% 9% 248 248 248 1 All products in this catalog meet the new wire bending space requirements as identified in 1 990 NEC Section 373-6 (b). October 1 991 c 1 8'12 1 8'12 1 8'12 6 Pole U n its - 200 Amperes NEMA 1 NEMA 3R NEMA 1 2 MM .c om Catalog 30-150 Page 1 2 Safety Switches Motor Circuit Switches Safety Switch Catalog Number Interpretation Data : 2nd 3rd 4th Enclosure Type Protection Wires N E MA 3R N E MA 4/4X N E MA 1 2 P l u g Fuse R w J Gen. Duty G Double Throw X Heavy Duty Non-Fused p Fused Voltage 2 Wire u 3 Wire F 600V 3 4 Wire H 250V 2 6th 7th Current Options CD 30A - 1 2 60A - 2 6 1 00A - 3 4 200A - 4 400A 600A 800A 1 200A - Neutral + N Tang Term i n a l provis i o n s (30-200A) Copper Term i n a l s (30-200A) A c 5 6 7 8 an N E MA 1 I� ua ls 1 st CD Factory assembled options are available on special order with List Price Adder. Options marked with ( + ) are available as field installed accessory kits. 2nd 3rd Fused 7th 3 6 4 C 3 Wire 600 Volt " N " or "K" in this position (preced i n g n u m bers) i n d icates complia nce with 1 990 NEC Section 373-6 (b) for w i re ben d i n g space. 200 A m p With Copper Terminal Option. ca NEMA ENCLOSURE TYPE DEFINITIONS NEMA Standard 1 - 1 0- 1 979 tri Type 1 enclosures are i ntended for indoor use primarily to provide a deg ree of protection a g a i n st contact with the enclosed equipment. Type 3R enclosures are intended for outdoor use pri marily to provide a degree of protection a g a i n st fa l l i n g rain, sleet, and externa l ice formation. Type 12 enclosu res are intended for indoor use primarily to provide a degree of protection a g a i n st d u st, fa l l i n g d i rt, and dripping noncorrosive liquids. lec 3R 6th lP Heavy Duty * 1 5th ar N* N EM A 3R Enclosure 4th tM 1 st 12 4 Type 4X enclosures - same as Type 4 except they also provide a degree of protection a g a i n st corrosion and must have enclosures fabricated from sta i n l ess steel, polymerics or equivalent materi a l . .E 4X Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown d u st and rain, splashing water, and hose-di rected water. Note: Above i nformation i s for identification p u rposes only. Do not use to con­ struct catalog n u m bers not l i sted in this cata log. ww w Westi ng house E l ectric Corporation Distribution and Control Busi ness U n it Standard Distribution Products Division Pittsburgh, Pennsylvania, U . S.A. 1 5220 Printed in U.S.A. October 1 991