JT824-2, JT824-3 2' × 4' Dedicated T8 Lensed Troffer / 2 or 3-Lamp T8 PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION FEATURES • T8 optimized fluorescent lensed troffer • Shallow design frees up plenum space • Hemmed fixture edges reduce risk of injury during fixture handling and installation • Integral T-bar clips quickly secure fixture to the grid • Corner hinging for easy insertion and removal of shielding frame • Housing embossments provide extra strength and rigidity • Housing ends secured by unique corner interlock and screws • Snap-in ballast cover requires no tools for wireway access • Flush steel shielding frame, screw assembled for easy diffuser replacement • Rotary action cam latches. Smooth operating for secure shielding retention • Metal to metal light leak protection on all four sides of shielding frame • Rotary lock lampholders for positive lamp contact • Heat sink embossments behind ballasts for cooler operation, longer life • Recessed, surface or cable mount • UL listed 1598 Housing is constructed of heavy gauge steel, die formed for extra rigidity. Four T-bar clips integral to housing. Housing features hemmed edges. Door frame hinges and latches from either side. Wireway accessible from below for upgrades or maintenance. BALLASTS Energy efficient, thermally protected, automatic resetting, Class “P”, high power factor, sound rated A, unless otherwise specified. For a specific vendor and/or ballast, specify as option. CEE NEMA Premium compliant. ELECTRICAL Standard class "P," thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/ CECcompliant ballast disconnect is standard. FINISH 24 MODEL – 32 NO. OF LAMPS JT8 Dedicated T8 Lensed Troffer 2 Two 3 Three – – SHIELDING VOLTAGE G Inverted T-Bar1 SM Surface Mount CM Cable Mount2 A12 Pattern 12 Acrylic 0.100" Nominal (Std.) A12.125 Pattern 12 Acrylic 0.125" Nominal A19 Pattern 19 Acrylic 0.156" Male Prism PC1 Silver Parabolic Louver 1/2" × 1/2" × 1/2" For more shielding, see Options and Accessories. U 120V-277V 347 347V DOOR STYLE FS Flush Steel FA Flush Aluminum For additional door styles contact your local Columbia Lighting representative. ACCESSORIES (ORDER SEPARATELY) FK24 2' × 4' Flange Kit FKCR Flange Kit Continuous Row Connector CM48Y2SC3F-KIT 48" Cable Mount Kit for 2' wide CM ceiling type, 3 Wire Feed Cord For drywall order flange kit accessories separately. Order hanger accessories separately. 3 In-Fixture Module Antenna adds 2" to overall fixture height at power feed location. 4 Not available with Surface Mount ceiling types. 5 Provides ends with wiring access for continuous row mounting. 6 Contact Hubbell representative for continuous row, 3-lamp fixtures. 1 2 Page 1/3 Rev. 11/13/15 – CEILING TYPE SIZE LAMP TYPE CERTIFICATION All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. UL Sanitation Approved. EXAMPLE JT824-232G-FSA12-EU-FO735- C388-GLR 24 2' × 4' 32 4', T8: 32, 30, 28 or 25 Watt CEILING COMPATIBILITY Designed for recessed installation in standard inverted tee grid ceilings (G), recessed installation in hard ceilings (G with FK accessory), Surface mount at ceiling plane (SM) or cable mount suspension below ceiling plane (CM). For compatibility with specific ceilings contact your Hubbell Lighting representative. All metal parts processed with a phase phosphate bonding treatment. Grid units are pre-painted with high gloss baked white enamel, 86% reflective. Polyester powder coat paint after fabrication (PAF) option available, reflectance 90%. ORDERING INFORMATION JT8 SHIELDING 100% virgin acrylic prismatic 12, extruded and roll-embossed, diagonally oriented female prisms standard. Other shielding may be specified. If desired shielding media is not shown in ordering guide, contact your local Hubbell Lighting representative. BALLAST E Electronic T8, Instant Start 3E 3-Lamp Electronic T8, Instant Start 24E (1) 2-Lamp & (1) 4-Lamp Electronic T8, Instant Start (For use with MS9) OPTIONS F830 F835 F841 GLR EL PAF MS9 C388 C384 C488 C424 M4R G1 G2 G3 WIH 30K 78+CRI T8 Lamps Installed 35K 78+CRI T8 Lamps Installed 41K 78+CRI T8 Lamps Installed Fast Blow Fuse Emergency Battery Pack Installed Paint After Fabrication Master/Satellite w/9' Harness 3/8" Flex with 3 No. 18 Wires 3/8" Flex with 3 No. 14 Wires 3/8" Flex with 4 No. 18 Wires 1/2" Flex with 4 No. 14 Wires Specular Reflector Single Gasket (Door to Housing) Double Gasketing (G1 and Lens to Door) Triple Gasketing (G2 and Housing to Ceiling) wiHUBB Enabled3,4 EP Electronic T8, Programmed Start 3EP 3-Lamp Electronic T8, Programmed Start ELW 2-Lamp Electronic T8, 0.77 Ballast Factor, Low Wattage, Instant Start EOR End of Row (SM/CM only)5,6 3ELW 3-Lamp Electronic T8, 0.77 INT Intermediate (SM/CM only)5,6 Ballast Factor, Low Wattage, CP Chicago Plenum Instant Start For a complete set of options, see Options and For a specific ballast vendor, show as Accessories. option. LENSED TROFFERS / JT824-2, JT824-3 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com JT824-2, JT824-3 2' × 4' Dedicated T8 Lensed Troffer / 2 or 3-Lamp T8 PHOTOMETRIC DATA Test 13120 Test Date 11/07/2003 AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) 0.0 22.5 45.0 67.5 90.0 Average Luminance Angle JT824-332G-FSA12 J Lensed Troffer 2' x 4' 3-Lamp with A-12 Pattern Acrylic Prismatic Lens Luminaire B332I120RH-A 0.88 F32T8 2900 Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion 84 N/A 0 30 40 45 50 55 60 65 70 75 80 85 4289 4196 3635 3655 3299 2993 2706 2420 2178 2101 2255 2344 4289 4277 4032 3764 3469 3133 2694 2238 1908 1792 1822 2009 4289 4409 4230 3994 3761 3443 2903 2231 1643 1501 1831 2079 4289 4495 4421 4218 3940 3569 3078 2547 2223 2130 2229 2555 4289 4518 4515 4355 4047 3647 3161 2631 2326 2368 2583 2696 0º = 1.23 90º = 1.36 ZONAL LUMEN SUMMARY RCR LUMINAIRE DATA RC RW 1 2 3 4 5 6 7 8 9 10 70 93 85 78 71 66 61 57 53 49 46 80 50 30 89 85 78 73 69 63 62 55 55 48 50 43 45 38 42 35 38 31 35 29 10 82 68 58 49 43 38 33 30 27 24 70 50 30 87 84 77 72 68 62 61 54 54 48 49 42 45 38 41 34 38 31 35 29 70 90 83 76 70 64 59 55 51 48 45 10 81 67 57 49 42 37 33 30 27 24 50 83 74 65 59 53 48 44 40 37 34 INDOOR CANDELA PLOT 50 30 81 70 60 53 47 42 37 34 31 28 10 79 66 56 48 42 37 33 29 27 24 90 0 0 72 61 52 45 39 35 31 28 25 23 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Zone Lumens Lamp Fixt. Total Luminaire Efficiency 84.6% 0-30 0-40 0-60 0-90 0-180 2232 3678 6216 7364 7364 25.7 42.3 71.4 84.6 84.6 30.3 49.9 84.4 100.0 100.0 Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 77 Non-Compliant $3.12 based on 3000 hrs. and $0.08 per KWH Test 13121 Test Date 1/8/03 0.0 22.5 45.0 67.5 90.0 B232I120RH-A 0.88 F32T8 2900 Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion 60 N/A 0 30 40 45 50 55 60 65 70 75 80 85 2967 2850 2638 2430 2198 1973 1757 1577 1509 1596 1716 1780 2967 2921 2733 2537 2308 2046 1754 1461 1302 1329 1450 1656 2967 3045 2893 2719 2513 2220 1806 1377 1100 1169 1389 1568 2967 3133 3073 2912 2669 2327 1923 1563 1361 1377 1512 1709 2967 3155 3160 2986 2714 2394 2036 1752 1603 1650 1778 1850 0º = 1.23 90º = 1.36 ZONAL LUMEN SUMMARY RCR JT824-232G-FSA12 J Lensed Troffer 2' x 4' 2-Lamp with A-12 Pattern Acrylic Prismatic Lens Luminaire AVG. LUMINANCE (Candela/Sq. M.) COEFFICIENTS OF UTILIZATION (%) Average Luminance Angle LUMINAIRE DATA RC RW 1 2 3 4 5 6 7 8 9 10 70 94 87 79 73 67 62 58 54 50 47 80 50 30 91 87 80 74 71 64 63 56 57 49 51 44 47 39 43 36 39 32 36 30 10 84 70 59 50 44 39 34 31 28 25 70 92 84 77 71 66 61 56 53 49 46 70 50 30 89 85 78 73 69 63 62 55 56 49 50 43 46 39 42 35 39 32 36 29 10 83 69 58 50 44 38 34 31 28 25 50 85 75 67 60 54 49 45 41 38 35 50 30 82 71 62 54 48 43 38 35 32 29 10 80 67 57 49 43 38 34 30 27 25 0 0 74 62 54 46 40 36 32 28 26 23 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Zone Lumens Lamp Fixt. Total Luminaire Efficiency 86.3% 0-30 0-40 0-60 0-90 0-180 1542 2538 4234 5004 5004 26.6 43.8 73.0 86.3 86.3 30.8 50.7 84.6 100.0 100.0 Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 73 Non-Compliant $3.29 based on 3000 hrs. and $0.08 per KWH DIMENSIONAL DATA INDOOR CANDELA PLOT CEILING COMPATIBILITY FK24 Flange Kit Type G 31/8" 24" 2' × 4' 2-Lamp Lay-In Side 48" End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. 4½" 3" A K 35/32" Side End For hard ceiling applications order FK24 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK24 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK24 & (1) FKCR) FKCR 33/32" A: 7/8" Diameter knockout K: 2" × 3" through hole for access plate. Row cut out dimensions using FK24 & FKCR adapters: NOTE: All dimensions are in inches; dimensions and Width 243/8", Length [48" × (# in row)] + 3/8". Example: (48" × 2) + 3/8"= 963/8" specifications are subject to change without notice. Please consult factory or check sample for verification. Flange kit rough in dimensions for single unit only: 243/8" × 483/8" Page 2/3 Rev. 11/13/15 LENSED TROFFERS / JT824-2, JT824-3 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com JT824-2, JT824-3 2' × 4' Dedicated T8 Lensed Troffer / 2 or 3-Lamp T8 DIMENSIONAL DATA - SURFACE MOUNT (SM) AND CABLE MOUNT (CM) 445⁄8" Mounting Holes: (4) 1⁄4–1⁄2" DIA KOs (A) 43⁄4" 123⁄8" 11⁄2" Thru Hole 123⁄8" 41⁄2" x 5" Mounting Collar (SM only). For Cable Mount (CM) a 2" x 3" access plate with (2) 7⁄8" K.O.s provided in place of Mounting Collar shown. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. 14" 5" 25" 49" 33⁄4" Side View End View SURFACE MOUNT CABLE MOUNT Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 1⁄4" to 1⁄2" provided as shown, marked "A". Order CM ceiling type. Access plate supplied for cable mounting or suspension. Use CM48Y2SC3F-KIT 48" cable mount kit. Includes 3 wire feed cord. For other wiring needs, contact Hubbell Lighting representative. Mounting knock-outs, 1⁄4" to 1⁄2", provided as shown, marked "A". Page 3/3 Rev. 11/13/15 LENSED TROFFERS / JT824-2, JT824-3 © 2015 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com