Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas ◦Type of protection : Lighting fitting : ExdeⅡB+H2T3X (180-360W) Lighting fitting : Ballast : ExseⅡT4X The NZAB lighting fittings are qualified for use in hazardous areas of Zone. 1 and 2 by the TIIS. The lighting fitting consists of a flameproof lamp house and an increased-safety terminal compartment. The ballast consists of a flameproof ballast box and an increasedsafety terminal box. They are designed and constructed thoroughly with carefully selected materials to provide high reliability in protection against explosion. ◦Degree of protection : IP65 They have a dust- and jet-proof structure which meets the IP65 requirements of the IEC standards, ensuring trouble-free operation in outdoor use. ◦High corrosion resistance The body is made of corrosion-proof aluminium alloy, and the bolts are made of stainless steel. ◦Easy lamp replacement The lamp can be replaced simply by loosening the four bolts on the lamp cover holder. ◦Easy installation and wiring Installation is easy since the body is suspended by a union coupling at the terminal box. The terminal box has power cable entries and a removable cover to permit wiring work after installation of the lighting fitting. ■SPECIFICATIONS ◦Rated voltage : 100V, 200V (Other voltages can be supplied upon request.) ◦Materials of main components corrosion-proof aluminium alloy casting Body : Ballast box : corrosion-proof aluminium alloy Terminal box : corrosion-proof aluminium die casting Lamp cover : hard glass Reflector : aluminium sheet Suspension pipe : carbon steel ◦Colour : Mild grey (Munsell 10YR7/1) ◦Finish : melamine resin coating ◦Entries : four ways (G1/2 or 3/4 thread) with three blind plugs ◦Guard (Cat. No. G) and external reflector (Cat. No. R) can be optionally supplied. ◦Photometric data : see P.11 ◦External reflector (stainless steel) ◦Guard (stainless steel bar) ◦External reflector (Cat. No. R) ◦Guard (Cat. No. G) 1 Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas Type of protection body : ExdeIIB+H2T3X ballast : ExseIIT4X 180W-360W (ceilling) Wattage 140 60 H2 High P.F. 4-φ10holes 70 2-10×15holes Cat. No. 180W NZAB18941 H1 40 220W NZAB22941 702 Support 270W NZAB27941 360W NZAB36941 Voltage (V) Freq. (Hz) Mass (kg) 100 50(60) 20.0 200 50(60) 18.0 100 50(60) 20.5 200 50(60) 18.0 100 50(60) 21.0 200 50(60) 18.0 100 50(60) 22.0 200 50(60) 18.0 φ298 H H2=420 Support ○ High P.F., 200V High P.F., 360W, 100V H1=327 H2=500 – ○ (pipe pendant) High P.F. 4-φ10holes 70 2-10×15holes 140 Wattage 60 Cat. No. 180W NZAB18942 H2 H1 220W NZAB22942 40 Support 270W NZAB27942 852 180W-360W Ballast High P.F., 180W-270W,100V 360W NZAB30942 φ298 3 Ballast High P.F., 180W-270W, 100V High P.F., 200V High P.F., 360W, 100V Voltage (V) Freq. (Hz) Mass (kg) 100 50(60) 20.5 200 50(60) 18.0 100 50(60) 21.0 200 50(60) 18.0 100 50(60) 21.0 200 50(60) 18.5 100 50(60) 22.0 200 50(60) 18.5 H H2=420 H1=327 H2=500 Support ○ – ○ Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas Type of protection body : ExdeIIB+H2T3X ballast : ExseIIT4X (bracket) 60 Support 70 H2 2-10×15holes H1 180W-360W 140 60 ゜ 40 500 4-φ10holes 650 8 9 φ2 High P.F. Ballast High P.F., 180W-270W, 100V H H2=420 Support ○ High P.F., 200V High P.F., 360W, 100V H1=327 H2=500 – ○ 4 Wattage Cat. No. 180W NZAB18946 220W NZAB22946 270W NZAB27946 360W NZAB36946 Voltage (V) Freq. (Hz) Mass (kg) 100 50(60) 20.5 200 50(60) 18.0 100 50(60) 21.0 200 50(60) 18.0 100 50(60) 21.0 200 50(60) 18.5 100 50(60) 22.0 200 50(60) 18.5 Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas Type of protection body : ExdeIIB+H2T3X 180W-360W (ceilling) 85 4-φ9holes 611 25 85 Wattage Cat. No. Mass (kg) 180W NZAB18041 11.5 220W NZAB22041 11.5 270W NZAB27041 11.5 360W NZAB36041 11.5 Wattage Cat. No. Mass (kg) 180W NZAB18042 12.0 220W NZAB22042 12.0 270W NZAB27042 12.0 360W NZAB36042 12.0 Wattage Cat. No. Mass (kg) 180W NZAB18046 12.0 220W NZAB22046 12.0 270W NZAB27046 12.0 360W NZAB36046 12.0 φ298 180W-360W (pipe pendant) 85 4-φ9holes 761 25 85 φ298 (bracket) 4-φ9holes 25 85 557 60 ゜ 500 85 180W-360W 8 9 φ2 6 Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings (stanchion) Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas With separate ballast 180W-360W Type of protection body : ExdeIIB+H2T3X 400 φ48.6 Wattage Cat. No. 110W NZAB11051 180W NZAB18051 220W NZAB22051 270W NZAB27051 360W NZAB36051 800 or more 2025 φ298 2600 Stand pole : rust-proof With ballast on Pole 180W-360W Type of protection body : ExdeIIB+H2T3X ballast : ExseIIT4X 400 φ48.6 Wattage Cat. No. 110W NZAB11951 180W NZAB18951 220W NZAB22951 270W NZAB27951 360W NZAB36951 Stand pole : rust-proof 2025 2600 φ298 800 or more 4-φ10holes 140 75 H 70 40 Ballast High P.F., 180W-270W, 100V High P.F., 200V High P.F., 360W, 100V 7 H H=397 H=327 H=477 Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings (pole) Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas Type of protection body : ExdeIIB+H2T3X ballast : ExseIIT4X B-type pole C-type pole Ringed type pole 400 1405 1000 φ48.6 34 φ φ48.6 φ89.1 7000 ballast φ89.1 7000 gasket φ165.2 15゜ 7000 φ89.1 cover φ165.2 400 2-50×100Cable entry slot 250 350 2-50×100Cable entry slot 1200 2-50×100Cable entry slot 4-φ30holes 1200 400 400 1200 1-φ150holes φ165.2 φ165.2 250 350 Bolted base type Wattage Cat. No. Planted Wattage NZAB18961 180W (Bolted base type) NZAB18962 B | t y p e 220W (Bolted base type) NZAB22962 (Planted) NZAB27961 270W (Bolted base type) NZAB27962 (Planted) 180W (Bolted base type) NZAB36962 (Planted) Wattage NZAB18966 C | 220W t y p 270W e NZAB22965 (Bolted base type) NZAB22966 (Planted) NZAB27965 (Bolted base type) NZAB27966 (Planted) NZAB36965 360W (Bolted base type) NZAB36966 (Planted) Cat. No. NZAB18967 (Bolted base type) (Planted) NZAB36961 360W Cat. No. NZAB18965 (Planted) NZAB22961 Planted Planted R i n g e d t y p e 180W (Bolted base type) NZAB18968 (Planted) NZAB22967 220W (Bolted base type) NZAB22968 (Planted) NZAB27967 270W (Bolted base type) NZAB27968 (Planted) NZAB36967 360W (Bolted base type) NZAB36968 (Planted) Pole : rust-proof 8 Explosion-proof Type High-pressure Sodium Lamp Lighting Fittings Products conforming to the international standard (IEC Standard 60079) Zone. 1 and 2 Areas Type of protection body : ExdeIIB+H2T3X ballast : ExseIIT4X 180W-360W High P.F. Cat. No. 180W NZTB1897 220W NZTB2297 270W NZTB2797 360W NZTB3697 530 φ420 500 Wattage 40 H 140 60 Freq. (Hz) 70 Mass(kg) 100V 50(60) 36.0 200V 50(60) 33.5 100V 50(60) 36.0 200V 50(60) 33.5 100V 50(60) 36.5 200V 50(60) 34.0 100V 50(60) 37.5 200V 50(60) 34.0 Ballast High P.F., 360W 100V High P.F., 180W-270W 100V High P.F., 180W-360W 200V 2-10×15 4-φ10 Voltage (V) H H=495 H=415 H=345 Support ○ ○ ○ 180W-360W 365 φ420 500 3-φ13 0 R9 120゜ 0゜ 12 9 Wattage Cat. No. Mass (kg) 180W NZTB1807 27.0 220W NZTB2207 27.0 270W NZTB2707 27.0 360W NZTB3607 27.0 PHOTOMETRIC DATA NZAB36 Ceiling Reflec Wall tance Floor 0.60 0.80 1.00 1.25 1.50 Room 2.00 index 2.50 3.00 4.00 5.00 10.00 Coefficient of utilization 70% 50% 50% 30% 10% 50% 30% 10% 10% .241 .175 .128 .216 .158 .117 .301 .230 .178 .270 .209 .163 .357 .286 .231 .321 .260 .213 .406 .335 .280 .365 .305 .257 .444 .375 .320 .400 .342 .294 .498 .434 .380 .450 .396 .350 .538 .479 .428 .488 .438 .394 .566 .511 .462 .514 .467 .426 .607 .558 .514 .552 .511 .474 .630 .586 .546 .575 .538 .503 .700 .671 .644 .643 .619 .596 Lighting Fittings Lamp Lamp Lumens Lamp Output Ratio Lighting Fittings Lamp Lamp Lumens Lamp Output Ratio NZAB22 NH220F・L 26500m 73% cd/1000m 30% 0% 30% 10% 0% .133 .180 .227 .269 .302 .352 .390 .417 .458 .482 .557 .096 .140 .187 .229 .263 .314 .355 .384 .428 .455 .539 .073 .112 .156 .194 .226 .274 .312 .340 .382 .407 .489 150゜ 2 10000 8 6 120゜ 120゜ 90゜ 90゜ 25 50 60゜ 60゜ 75 30゜ 100 NH360・L NH360F・L 4 180゜ 150゜ LUMINOUS INTENSITY .216 .274 .328 .374 .410 .462 .500 .527 .565 .587 .652 Coefficient of utilization 70% 50% 30% 10% 50% 30% 10% 10% .154 .110 .199 .143 .103 .207 .158 .252 .193 .149 .261 .210 .302 .244 .198 .308 .256 .345 .288 .242 .346 .294 .379 .324 .278 .402 .351 .428 .376 .333 .444 .397 .464 .417 .375 .475 .429 .490 .446 .406 .519 .479 .526 .488 .453 .546 .508 .548 .513 .481 .626 .601 .613 .591 .569 100000 8 6 30゜ 125 0゜ cd/1000ℓm 50% .143 .188 .235 .277 .310 .360 .398 .425 .466 .491 .568 .105 .148 .194 .235 .269 .320 .361 .391 .435 .462 .549 .076 .111 .152 .188 .218 .264 .301 .327 .369 .393 .476 180゜ 150゜ 150゜ 120゜ 120゜ 90゜ 90゜ 25 50 60゜ 60゜ 75 30゜ 100 30゜ 125 0゜ NZTB36 NZAB22 Ceiling Reflec Wall tance Floor 0.60 0.80 1.00 1.25 1.50 Room 2.00 index 2.50 3.00 4.00 5.00 10.00 NZAB36 NH360F・L 47500m 80% cd/1000m 30% 0% 30% 10% 0% 4 2 1000 8 6 4 2 100 8 6 4 2 0 10 20 30 40 50 60 70 80 90 DEGREE(° ) 11 LAMP LAMPLUMENS EFFICIENCY MAX. INTENSITY BEAM SPREAD BEAM FLUX BEAM EFFICIENCY NH360・L 50000 rm 37.6% 304842cd 23.2° 7650 rm 15.3% LAMP LAMPLUMENS EFFICIENCY MAX. INTENSITY BEAM SPREAD BEAM FLUX BEAM EFFICIENCY NH360F・L 47500 rm 34.7% 29937cd 83.2° 14630 rm 30.8%