MS6
MS6
Features
•
•
Beams
•
•
•
Direct/Indirect Rectilinear
T8, T5, or T5HO
Controls compatible
Separate up/down lamp compartments
create an efficient and creative optical
system
Nine different lamp and distribution
options provide flexibility for any
application
•
•
•
Multiple shielding options provide a
wide array of glare control levels
All steel housing is sturdy yet
economical
UL listed 1598. cUL or CSA. Damp
location listed
Ordering Information
MS6
–
–
Model
MS6 MS6
–
LAMP PROFILE & DISTRIBUTION
1U1D 1-Lamp Uplight,
1-Lamp Downlight1
1U2D 1-Lamp Uplight,
2U1D
Row Length
4 4' Single
8 8' Single
— Indicate
2U2D
1U1AD
2U1AD
row length
over 8' in 4' 1AU1D
increments
Note: Rows
over 8' will be
1AU2D
configured by
Alera. Example:
16' will be (2)
1AU1AD
8'. Alternate
configurations:
contact factory.
LAMP TYPE
T5 T52
T5HO T5HO2
T8 T8
–
–
SUSPENSION LENGTH
48 48"
96 96"
Not applicable for surface or
wall mount. Other lengths
available on request.
2-Lamp Downlight1
2-Lamp Uplight,
1-Lamp Downlight
2-Lamp Uplight,
Mounting Method
Shielding
2-Lamp Downlight
LD Low Iridescent
1-Lamp Uplight, 1-Lamp CM Adjustable Aircraft
Cable
Semi-Specular Louver
Asymmetric Downlight1
LS Low Iridescent Specular
2-Lamp Uplight, 1-Lamp PM Pendant Mount
Louver
Asymmetric Downlight WM Wall Mount,
Symmetric Dist.
A12 Pattern 12 Acrylic Lens
1-Lamp Asymmetric
Uplight, 1-Lamp
WMW Wall Mount,
A19 Pattern 19 Acrylic Lens
Wall Wash3
Downlight
CA Clear Acrylic Lens
WMR Wall Mount,
1-Lamp Asymmetric
(No pattern)
3
Room
Wash
Uplight, 2-Lamp
Opal Acrylic Lens
OA
Downlight
White Cross Baffle
WCB
1-Lamp Asymmetric
NA No Shielding
Uplight, 1-Lamp
Asymmetric Downlight
Connector box required on all 1-lamp connector uplight units if pendant or cable mounted.
This option does not permit continuous shielding for all 1-lamp symmetric uplights.
2
T5/T5HO at risk for socket shadow in downlight component.
3
For use with asymmetric distributions.
1
–
–
Voltage
Finish
U 120V- MW Matte
277V
White
(Std.)
ZT ZET
Metallic
Silver
120 120V
277 277V
347 347V
Ballast
E Electronic, Instant Start
(Std. for T8)
EP Electronic, Programmed
Start (Std. for T5 & T5HO,
optional for T8)
ED Electronic, Dimming
(Must specify)
Unless specified, Alera will use
fewest ballasts possible.
Options
DC Dust Cover
(T8 or T5 only)
LR Left/Right
UB
EL
EMC
NLC
GLR
GMF
TBAR
Switching4
Upper/Lower
Switching4
One Emergency
Battery Pack5, 6
One Emergency
Circuit6, 7
Night Light
Circuit 6, 7
Fast Blow Fuse
Slow Blow Fuse
T-Bar Mounting
LR requires 2 lamps in cross section. UB assumes 1 circuit up, 1 circuit down.
Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120).
Not available with all configurations; some limitations apply. Contact factory for details.
7
One extra feed drop per row for EMC/NLC. For through wiring, contact factory.
4
5
6
CROSS SECTIONS
6"
7¾"
MS6-1U1D6
MS6-1U2D6
MS6-2U1D
MS6-1AU1D
MS6-1AU2D
MS6-1AU1AD
MS6-2U2D
Name:
Test #:
Efficiency:
LER:
MS6-1U1AD6
MS6-2U1AD
MS6-1U1DT8-LD-E
10976
68.5%
63
Specifications subject to change without notice.