MRI SOLUTIONS RF SHIELDING RF SHIELDED DOORS, WINDOWS AND LIGHTING MRI SAFETY ENGINEERING SERVICES ets-lindgren.com MRI SHIELDING Shielding Solutions Radio Frequency (RF) and magnetic interference from nearby office systems, electrical equipment, or even passing traffic, can degrade MRI image quality. ETS-Lindgren’s experts can select and install the right RF shield for each situation, protecting your investment and letting you see results clearly. Most MRI rooms only need RF shielding, but some may require magnetic shielding as well. ETS-Lindgren can perform an on-site survey to determine the type of shielding needed. MRI image quality can be degraded by interference. RF Shielding – Walls and Ceilings MR-CU Shield System ETS-Lindgren’s MR-CU Shield System is made of copper sheeting attached to a modular frame of fire-rated Laminated Veneer Lumber (LVL). The modules install quickly and can be adapted easily to the specific requirements of a particular room. Because the modules are structurally independent of the parent MRI room’s walls, they provide an added seismic component. Add our optional sound kit for increased acoustic attenuation. MR-CU Shield System offers architectural flexibility. RF Shielding – Floors Like walls and ceilings, floors require RF shielding as well. ETS-Lindgren offers two types of shielded flooring; Monolithic and Modular. Monolithic Our in-place Monolithic floor consists of structurally bonded materials that include a copper RF attenuator, dielectric material, and a moisture resistant barrier. Monolithic flooring is an ideal solution for installations in moist, damp environments. Monolithic flooring has a moisture resistant barrier for an extra layer of protection. Modular Modular flooring uses our Series 81 modular shielded panel system. Panels are made with shielding material laminated to both sides of a wood core. Galvanized steel, copper or aluminum are the materials usually used for RF shielded floor applications. A mechanical clamping system joins the panels together. Modular flooring is a good choice when quick installation is required. Modular flooring installs quickly. RF and Magnetic Shielding Sometimes magnetic shielding is needed in addition to RF shielding. This may be necessary when the MRI room shares a common wall with another room containing sensitive electronic equipment, or one with equipment that generates strong magnetic fields. When this occurs, a separate magnetic shield can be constructed around the RF shield. Silicon Steel Silicon Steel provides the highest level of shielding from magnetic fields. This shielding is also utilized to contain energies of concern, such as an MRI rated at 3T or above. Series 81 Modular RF Shielding Panel Series 81 Series 81 is a modular laminate panel system. Panels are made with an appropriate shielding material bonded to both sides of a wood core. A mechanical clamping system joins the panels together. Series 101 Series 101 is a modular pan-type shielded panel system. Panels are shaped in the form of a rectangular pan, and made entirely of metal. Pans fasten together with bolts. Series 101 Modular RF Shielding Panel MRI SHIELDING Options Magnetic Active Cancellation Systems (MACS™) Sometimes, MRI systems (or other medical devices) may require more protection from magnetic interference that is not possible with passive shielding alone. ETS-Lindgren’s Magnetic Active Cancellation System (MACS) is an active system with real-time magnetic field compensation for AC/DC magnetic field fluctuation. In some instances, potential sites that were previously rejected because of high magnetic fields have become usable after a MACS system was installed. MACS units are small in size, self-contained, and are easily installed. They require no maintenance or adjustments after installation, under normal operating conditions. MACS systems are designed for continuous operation. MACS Unit Image Quality Before MACS Image Quality After MACS Electrical Power and Signal Line Filtering Our medical filters prevent RF interference from being conducted along electrical power and signal lines to connected medical equipment. ETS-Lindgren has an extensive selection of filters to block RF interference. EMI/RFI Shielded Waveguide Air Vents Waveguide air vents allow the free-flow of air into a shielded room for ventilation, and prevent electromagnetic interference from entering the room where the waveguides are installed. Filters prevent transmission of conducted RF noise. Soundproofing ETS-Lindgren has solutions to reduce distracting and disruptive noise in MRI rooms. Installing acoustic material in walls, fitting baffles to ventilation ducts, and isolating sources of vibration are some of the methods used to create a quiet environment. Waveguides allow airflow but stop RF noise. MRI SHIELDED DOORS, WINDOWS, AND LIGHTING Swing Doors – Single and Double Leaf Auto-Seal™ II ETS-Lindgren’s Auto-Seal II is our most advanced and configurable MRI swing door. The door’s key feature is a pneumatically activated sealing mechanism that provides trouble-free operation and minimal maintenance. Standard Features • Single Leaf (In or Out Swing) • Classroom Function Handle • ADA Compliant Door Threshold • Choice of Door Laminate • STC 29 Acoustic Rating • UL Listed Power Supply Options • Double Leaf (In or Out Swing) • Automatic Opener/Closer Combination • Automatic Closer Only • RF Shielded Window • Lead Shielding (up to 6.35 mm/.25 in) • STC 40 Acoustic Rating • 20 Minute Fire Rating (Requires Stainless Steel Finish) • IV Port Feedthrough Customize your door with our list of options. MRI SHIELDED DOORS, WINDOWS, AND LIGHTING MRDS ETS-Lindgren’s MRDS MRI Door is designed for ease-of-use and durability, with a pleasing style that is appropriate for most hospital environments. Standard Features • Single Leaf (In or Out Swing) • Ball-bearing Hinges • Ergonomic Handle • Key and Standard Deadbolt Latch Hardware • Low Profile Door Threshold Options • Double Leaf (In or Out Swing) • RF Shielded Window • STC 34 Acoustic Rating • Choice of Door Laminates • Safety Hatch Door for In Swing Doors • Magnetic Locks Customize your door with our list of options. Slide Doors – Double Sliding SSD ETS-Lindgren’s SSD Sliding Door system was developed for the special requirements of multiroom, intraoperative suites. One of the door’s key features is a pneumatically actuated sealing mechanism that provides trouble-free operation and minimal maintenance. Standard Features • Single Leaf Sliding • Reverse On Contact Sensors • Expansion Seal for Acoustic and Hygienic Management • ADA Compliant Door Threshold • Emergency Overrides Options • Double Leaf Sliding • Approaching Object, Bi-Directional Motion Sensors • Door Position Indicators • Lead Shielding (up to 6 mm/.25 in) Advanced Technology SSD Intraoperative Sliding Doors. Clearshield™ Window Solutions Window Wall1 ETS-Lindgren’s Clearshield Window Wall gives your room an open airy feeling, with clear views of the surrounding landscape and open sky. The Window Wall’s RF attenuating properties block RF interference while providing clear views. Features • Large 122 cm x 152 cm (48 in x 60 in) Maximum single panel size. Panels can be combined to form larger structures. • 100 dB Attenuation @ 150 MHz • Suitable for 3T MRI • STC 40 Acoustic Rating • Functions as a Wall, Skylight or Observation Window • Can be Removed/Replaced for Magnet Egress Let light in, keep RF noise out. Observation Window ETS-Lindgren’s observation windows provide a combination of clear viewing with high RF attenuation levels. You can see perfectly, yet the transmission of RF interference is essentially blocked. Features • Large 122 cm x 183 cm (48 in x 72 in) Maximum Single Panel Size. • 100 dB Attenuation @ 150 MHz • Suitable for 3T MRI 1 Must be mated with an exterior window. See clearly without compromising shield integrity. MRI SHIELDED DOORS, WINDOWS, AND LIGHTING Shielded Lighting Solutions Med-Vizion™ GDP Systems2 ETS-Lindgren’s Med-Vizion Graphic Display Panel (GDP) system can transform a dreary windowless room into a visual oasis that elevates mood and lets patients and staff feel relaxed, engaged, and empowered. Our new low profile wall mounted units are a nominal 2.5 centimeters (1 inch) in depth, and can be surface mounted in a few hours or less. Ceiling units are easily installed in the most commonly used ceiling configurations. Transform dreary rooms into cheerful environments. Ambient Lighting Reduce patient anxiety and create a restful, calming environment during stressful MRI scans. Our ambient lighting system uses a programmed multi-color visual experience to sooth and calm. Med-Vizion™ ZXR LED Down Lighting Med-Vizion ZXR LED Down Lighting uses the latest LED technology for MRI compatible lighting with brightness equal to incandescent lighting, but consumes less power and lasts longer. Ambient lighting creates a restful, calming environment. Med-Vizion lamps include all necessary mounting hardware and trim rings. An optional dimmer switch assembly is available that can support up to 16 ZXR LED Down Lights. Suitable for 3T MRI 2 LED lighting saves energy and costs less to maintain. MRI SAFETY SAFESCAN® Ferromagnetic Detection Solutions Properly designed and installed ferromagnetic detection systems are a valuable tool as part of your MRI safety and screening system. ETS-Lindgren’s team of experts assures that your system is properly placed and installed correctly. The result is a dramatic decrease in the number of extraneous alarms experienced with other systems. You benefit with a safe and seamless workflow around the MRI doorway and throughout your MRI suite. OMS™ Oxygen Deficiency Monitor Inert gases used in medical settings can escape unnoticed, displacing oxygen and creating a health hazard for staff and patients. The OMS Oxygen Deficiency Monitor is a compact sample draw gas monitoring system that continuously monitors areas where gases may be used or stored. If the level of oxygen in the room or storage area falls below a safe limit, the OMS can be set to alarm both locally and at a remote monitoring station. The OMS uses zirconium oxygen sensor cell technology rather than older electrochemical detection methods. This allows the OMS to provide stable readings in areas where temperature and humidity levels are changing, and provides 10 or more years of continuous use with a minimum of maintenance. MRI safety includes ferromagnetic detection. OMS monitors O2 levels for safety. MRI ENGINEERING SERVICES Engineering and Consulting Solutions In addition to being a leading provider of MRI solutions, ETS-Lindgren is also a leader in EMC, RF microwave, wireless, and acoustic technology. As a result, we are able to approach problems with an extensive base of scientific knowledge and practical experience, giving us the ability to solve problems that elude others. RF RF testing includes measurements to determine the integrity of existing shield systems. Shield seams and joints, electrical and mechanical service penetrations, and door seals are all tested for loss. EMI When Electromagnetic Interference (EMI) is suspected as the problem, the ambient is scanned electronically to identify the source. Our team then determines the appropriate actions required to contain, eliminate, or lessen the effects. DC Magnetic Strong magnetic fields can have adverse effects on sensitive instrumentation. Our engineering team can identify magnetic sources and provide solutions including containment shielding and field cancellation (MACS). Acoustic Acoustic analysis includes measurements to determine noise sources, whether airborne or structurally transmitted. Solutions can include source elimination, isolation, and soundproofing existing structures. Vibration Analysis Noise can result from vibrations transmitted by structural members over long distances. A site analysis by our engineering team can determine the source and implement isolation measures. Our engineers and technicians have the experience and expertise gained from more than 10,000 installations. MODIFICATIONS AND RELOCATIONS Maintenance Services Periodic maintenance pays for itself in reduced downtime and unexpected expense. Our experienced service crews can visit your facility on a scheduled basis to prevent problems before they start. We offer maintenance contracts or as-needed call-in service. Shield Upgrades An aging facility, new equipment, or an increasingly RF noisy environment can dictate the need to install new or additional shielding. Our engineers can survey the ambient to determine the right amount of shielding needed, and then have it installed. Acoustic Upgrades Meeting environmental standards, a lack of soundproofing, or having existing soundproof materials that need reinforcement, are reasons you may need to call the team at ETS-Lindgren. Our experts can survey your needs and provide the right solution. Our after-sales support protects your investment. SALES AND SUPPORT OFFICES UNITED STATES – TEXAS CHINA Cedar Park, TX Beijing +1.512.531.6400 Phone +86(10)8273.0877 Phone +1.512.531.6500 Fax +86(10)8273.0880 Fax info@ets-lindgren.com china@ets-lindgren.com UNITED STATES – ILLINOIS JAPAN Wood Dale, IL Tokyo +1.630.307.7200 Phone +81.3.3813.7100 Phone +1.630.307.7571 Fax +81.3.3813.8068 Fax info@ets-lindgren.com japan@ets-lindgren.com UNITED STATES – WISCONSIN INDIA Minocqua, WI Bangalore +1.715.356.2022 Phone +91.80.4341.8600 Phone +1.715.356.2023 Fax +91.80.4341.8611 Fax info@ets-lindgren.com indiainfo@ets-lindgren.com BRAZIL SINGAPORE São Paulo Singapore +55(11)3123.9700 Phone +65.6391.0912 Phone +55(11)3123-9078 Fax +65.6298.9509 Fax info@ets-lindgren.com singapore@ets-lindgren.com GERMANY TAIWAN Taufkirchen Taipei +49.89.614171.0 Phone +886.2.27023389 Phone +49.89.614171.71 Fax +886.2.27023055 Fax germany@ets-lindgren.com taiwan@ets-lindgren.com FINLAND UNITED ARAB EMIRATES Eura Dubai +358.2.8383.300 Phone +971.55.610.4055 Phone +358.2.8651.233 Fax uae@ets-lindgren.com euinfo@ets-lindgren.com UNITED KINGDOM Stevenage, Hertfordshire +44.1438.730.700 Phone +44.1438.730.751 Fax uk@ets-lindgren.com FRANCE Boulogne Billancourt +33 (0) 1 74 31 10 21 Phone france@ets-lindgren.com THE SUREST SOLUTION BY ANY MEASURE™ ets-lindgren.com Information presented is subject to change. Actual product appearance may vary from representational photographs and illustrations shown. Contact the ETS-Lindgren Sales Department for current specifications. 6/15 100 RP/RR © 2015 ETS-Lindgren Rev. E