detail PERIMETER ZP-5 fluorescent series Project: Type: Catalog number: B recessed - grid & drywall mount A ordering data MODEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . specifications ZP-5 DIRECTION. . . . . . . . . . . . . . . . . . . . . . . . 11 3⁄ 8" The ZP-5 Perimeter has a 20 gauge cold rolled steel housing. Exterior will be powder coated white (standard). The die formed cold rolled steel reflector is painted with minimum 90% reflective gloss white enamel. See ordering key for shielding options. Wall mount flange recessed (WFR) is standard. Contact factory for other ceiling types and mounting styles. D N 1 2 8 3 ⁄ 4" ZP-5 Wall Mount Flange open - no shielding (1) T8 lamps shown T5 T5HO T8 N 1 lamp per cross section 2 lamps per cross section Standard output T5 lamp High output T5HO lamp Standard output T8 lamp (1) lamp only LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 4 6 8 X 2 ft. 3 ft. 4 ft. 6 ft. 8 ft. Replace X with run length. (specify run length in feet) MOUNTING. . . . . . . . . . . . . . . . . . . . . . . . This product is cULus listed for damp location. Available photometrics at atlantic-lighting.com. Wall mount flange WFR FINISH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WH CC White B Custom color VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications and dimensions subject to change without notice. WFR Wall mount flange D LAMP TYPE . . . . . . . . . . . . . . . . . . . . . . . 10" Ceiling Cutout WFR flange detail None ZP-5 NUMBER OF LAMPS . . . . . . . . . . T5/T5HO lamping has electronic programmed-start ballast <10% THD and high ballast factor standard. T8 lamping has electronic instant-start ballast <10% THD and high ballast factor standard. Contact factory for 347V, emergency battery packs and dimming options. WFR wall mount flange Direct SHIELDING. . . . . . . . . . . . . . . . . . . . . . . . 6" Available in one or two T8, T5 lamp cross sections. Grid mount test Perimeter, no diffuser test ZP-5 Wall Mount Flange open - no shielding (2) T5HO lamps shown Flange detail (drywall) UNIV 120 277 347 Universal 120-277V 120V 277V 347V A DIMMING. . . . . . . . . . . . . . . . . . . . . . . . . . . RBT Robertson 0-10V dimming (T5/T5HO) AD7 Advance Mark 7, 0-10V dimming (T5/T5HO/T8) AD10-1 Advance Mark 10, 2-wire dimming 120V (T5/T5HO/T8) AD10-2 Advance Mark 10, 2-wire dimming 277V (T5/T5HO/T8) STEPAdvance step dimming (T5/T5HO/T8) OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . EM EM1 ETS 2C EC IOTA emergency battery pack 500 lumen max IOTA emergency battery pack 1200 max IOTA emergency transfer switch Dual circuit wiring Emergency circuit P/N Example: ZP-5-D-N-1-T5-4-WFR-WH-277-RBT ZP-5- D - N-1-T5 - 4 - WFR - WH - 277-RBT model lamps dimming direction length finish options shielding mounting voltage T: 508 678-5411 | F: 508 678-5408 www.atlantic-lighting.com page 1 of 2 091415 ZL15-069