ZC-38 fluorescent series

advertisement
COVE
ZC-38 fluorescent series
Project:
Type:
Catalog number:
indirect concealed cove & wall mount
ordering data
MODEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
specifications
ZC-38
DIRECTION. . . . . . . . . . . . . . . . . . . . . . . .
ƒƒ The Cove series has a 20 gauge cold
rolled steel housing. Exterior will be
powder coated white (standard). The
die formed cold rolled steel reflector is
painted with minimum 90% reflective
gloss white enamel. See ordering key for
shielding options.
ƒƒ Concealed cove mount is standard. See
ordering data for more options and page 2
for individual mounting dimensions.
ƒƒ Available in one or two T5, T5HO or T8
lamp cross sections.
ƒƒ T5/T5HO lamping has electronic
programmed-start ballast <10% THD and
high ballast factor standard. T8 lamping
has electronic instant-start ballast <10%
THD and high ballast factor standard.
Contact factory for 347V, emergency
battery packs and dimming options.
I
Indirect
SHIELDING. . . . . . . . . . . . . . . . . . . . . . . .
N
3"
None
ZC-38
I
N
NUMBER OF LAMPS . . . . . . . . . .
1
2
1 lamp per cross section
2 lamps per cross section
LAMP TYPE . . . . . . . . . . . . . . . . . . . . . . .
T5
T5HO
T8
8"
Cove Mount
shown with (2) T5/T5HO lamp
Standard output T5 lamp
High output T5HO lamp
Standard output T8 lamp
LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
3
4
6
8
X
2 ft.
3 ft.
4 ft.
6 ft.
8 ft.
Replace X with run length.
(specify run length in feet)
MOUNTING. . . . . . . . . . . . . . . . . . . . . . . .
CV
W
This product is cULus listed for damp location.
Available photometrics at atlantic-lighting.com.
Concealed cove mount
Wall mount
FINISH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Mount
shown with (2) T8 lamp
Specifications and dimensions
subject to change without notice.
Fluorescent Cove
WH
TW
CC
White
Textured white
Custom color
VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNIV
120
277
347
Universal 120-277V
120V
277V
347V
DIMMING. . . . . . . . . . . . . . . . . . . . . . . . . . .
RBT
Robertson 0-10V dimming
(T5/T5HO)
AD7 Advance Mark 7, 0-10V
dimming (T5/T5HO/T8)
AD10-1 Advance Mark 10, 2-wire
dimming 120V (T5/T5HO/T8)
AD10-2 Advance Mark 10, 2-wire
dimming 277V (T5/T5HO/T8)
STEPAdvance step dimming
(T5/T5HO/T8)
OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . .
EM
EM1
ETS
2C
EC
IOTA emergency
battery pack 500 lumen max
IOTA emergency
battery pack 1200 max
IOTA emergency transfer
switch
Dual circuit wiring
Emergency circuit
P/N Example: ZC - 38 - I - N - 2 - T5 - 4 - CV - WH - 277 - EM
ZC - 38 - I - N - 2 - T5 - 4 - CV - WH - 277 - EM
model
shielding
options
lamp
direction
T:
508 678-5411 | F: 508 678-5408
www.atlantic-lighting.com
mounting
dimming
length
finish
page 1 of 2
091415
ZL15-057
Download