Untitled - Eaton Elektrotechnika sro

advertisement
Industrial
Hazardous Area Products
Eaton’s Crouse-Hinds business is the leader in the
field of explosion protection, committed to
technological progress, developing and
manufacturing a range of products that cover all the
requirements currently placed on modern,
explosion-protected, electrical installations,
including; illumination, safeguarding, signalling,
controlling, instrumentation and distribution of
electrical energy in potentially explosive
atmospheres. For more than 100 years CEAG has
delivered innovation and safety you can trust in
harsh and hazardous environments.
We supply products and solutions that comply with
all the latest directives and standards – worldwide.
In addition to systems and components built to
ATEX Directives and European Standards, the
company also provides solutions approvals, e.g. for
Eastern European countries, Russia and Kazakhstan
(GOST), China and North America. Many customers
operate in the oil and gas business, be it operators
of offshore platforms, gas fields, refineries or
pipelines or in the chemical and pharmaceutical
business. However, explosion protection is also
vital in a variety of other areas, such as mining,
food processing, bio-ethanol plants, waste water
treatment facilities or ship-building.
The following pages cover a small section of the
CEAG portfolio and include commonly used Zone
1/21 and Zone 2/22 luminaires and associated
switch gear and electrical junction boxes to satisfy
common project requirements. Where additional
hazardous area equipment is required then the full
range and expertise of the Crouse-Hinds business
can be accessed to fulfill your project
requirements.
LIGHTING SOLUTIONS
CLS-CC2055 - March 2014
355
Industrial
Ex-e Lighting Junction Box and Ex-safety Installation Switches
Ex-e Lighting Junction Box
Ex-Safety Installation Switches
Materials
Materials
• Housing - Impact resistant Polyamide, black
• Housing - Impact resistant Polyamide or GRP in black finish
• Screws and external metal parts - Stainless steel AISI 316L
Installation Notes
Installation Notes
• IP66 rated up to 180A
• Suitable for wall, trellis and pipe mounting
• Full AC 3-Phase switching capacity to EN 60947-4-1
• Suitable for Zone 1, 2, 21, 22 in accordance with EN60079-7
• Emergency Stop versions to EN 60204-1
• Designed with 6 x M20 metal thread cable entries, includes 4
threaded M20 plugs
Options
• IP66 rated
• Safety Switches or Emergency Stop switch options
• Zone 2/22 or Zone 1/21 certified variants
Certification
• 3 or 6 pole safety switches
• PTB 00 ATEX 3108
• 10A, 20A, 40A or 80A rated options
• Wide range of cable entry sizes: M20, M25, M32, M40 and
M50 combinations
Dimensions
73.5
10.5
Certification
56
• Refer to website for certification of the specific catalogue
reference selected
• Enter the catalogue reference in the keyword search on the
homepage: www.coopercrouse-hinds.eu
X 55
158
117.5
195
113.5
X 105
56
Dimensions
• Refer to website for certification of the specific catalogue
reference selected
• Enter the catalogue reference in the keyword search on the
homepage: www.coopercrouse-hinds.eu
356
LIGHTING SOLUTIONS
CLS-CC2055 - March 2014
Industrial
Ex-e Lighting Junction Box and Ex-safety Installation Switches
Catalogue Numbers
Part Number
Description
Lighting Junction Box
GHG7910201R0003
Lighting Junction Box EAZK 96 2 Metal Thread 6 x M20
Zone 2/22 Safety Switches
D222610005R0009
D222610005R0005
D222610005R0010
D222622301R0001
D222622301R0002
D222622601R0001
D222622602R0002
D222632301R0001
D222632301R0002
D222640020R0001
D222640020R0002
Zone 2/22 Safety Switch 10A 3-Pole 2xM25 1xM20
Zone 2/22 Safety Switch 10A 3-Pole 2xM20
Zone 2/22 Emergency Stop Switch 10A 3-Pole 2xM25 1xM20
Zone 2/22 Safety Switch 20A 3-Pole 2xM32 1xM25
Zone 2/22 Emergency Stop Switch 20A 3-Pole 2xM32 1xM25
Zone 2/22 Safety Switch 20A 6-Pole 4xM32 1xM25
Zone 2/22 Emergency Stop Switch 20A 6-Pole 4xM32 1xM25
Zone 2/22 Safety Switch 263 40A 3-Pole 2xM40 1xM25
Zone 2/22 Emergency Stop Switch 263 40A 3-Pole 2xM40 1xM25
Zone 2/22 Safety Switch 80A 3-Pole 2xM50 1 x M25
Zone 2/22 Emergency Stop Switch 264 80A 3-Pole 2xM50 1xM25
Zone 1/21 Safety Switches
GHG2610005R0009
GHG2610005R0010
GHG2622301R0001
GHG2622301R0002
GHG2622601R0001
GHG2622601R0002
GHG2632301R0001
GHG2632301R0002
GHG2630050R0001
GHG2630050R0002
GHG2640020R0001
GHG2640020R0002
GHG2640021R0001
GHG2640021R0001
Zone 1/21 Safety Switch 10A 3-Pole 2xM25 1xM20
Zone 1/21 Emergency Stop Switch 10A 3-Pole 2xM25 1xM20
Zone 1/21 Safety Switch 20A 3-Pole 2xM32 1xM25
Zone 1/21 Emergency Stop Switch 20A 3-Pole 2xM32 1xM25
Zone 1/21 Safety Switch 20A 6-Pole 4xM32 1xM25
Zone 1/21 Emergency Stop Switch 20A 6-Pole 4xM32 1xM25
Zone 1/21 Safety Switch 263 40A 3-Pole 2xM40 1xM25
Zone 1/21 Emergency Stop Switch 263 40A 3-Pole 2xM40 1xM25
Zone 1/21 Safety Switch 40A 6-Pole 4xM40 1xM25
Zone 1/21 Emergency Stop Switch 40A 6-Pole 4xM40 1xM25
Zone 1/21 Safety Switch 80A 3-Pole 2xM50 1xM25
Zone 1/21 Emergency Stop Switch 264 80A 3-Pole 2xM50 1xM25
Zone 1/21 Safety Switch 80A 6-Pole 4xM50 1xM25
Zone 1/21 Safety Switch 80A 6-Pole 4xM50 1xM25
Circuit Switches
GHG2732000R0003
GHG2736000R0003
Zone Circuit Switch ON-OFF 2-pole 16A IP66 2 x M20
Zone Change-Over Circuit Switch, 16A IP66 2 x M20
For further details, please refer to Eaton’s Crouse-Hinds business website, www.coopercrouse-hinds.eu
(Enter the catalogue reference in the keyword search on the homepage)
A useful and informative document covering the detail of hazardous area requirements, definitions and
product markings is downloadable from Eaton’s Crouse-Hinds business website at
www.coopercrouse-hinds.eu/en/principles-of-explosion-protection.
LIGHTING SOLUTIONS
CLS-CC2055 - March 2014
357
Industrial
Hazardous Area Luminaires
Lamp and Control Gear Options
Options
• 18W, 36W, 58W T8 fluorescent
• Fully integral emergency conversions, 1.5 or 3 hour duration
(not available on 58W T8)
• 11W PL-L fluorescent
• LED (Exit and Exit N only)
• High frequency control gear as standard
• Emergency with CEAG CG-S module for central battery
operation and monitoring available on some models
Photometric Data
Materials
• Body - eLLK/eLLM/nLLK - Glass fibre reinforced polyester
• Diffuser - eLLK/eLLM/nLLK - Polycarbonate
• Refer to the website for luminaire photometric data, available in
ldt and IES formats
• Enter the catalogue reference in the keyword search on the
homepage: www.coopercrouse-hinds.eu
• Housing - eLLB/D-RLF250 - Steel, white powder coat finish
• Protective cover - eLLB/D-RLF250 - 6mm/5mm thick safety
glass
Certification
• Exit housing and lens - EXIT LED - Polycarbonate
• Enter the catalogue reference in the keyword search on the
homepage: www.coopercrouse-hinds.eu
• Refer to the website for luminaire certification of the specific
catalogue reference selected
• Enclosure - EE 11 - Copper-free Aluminium
• Protective cover - EE 11 - Borosilcat-Glass
Dimensions
• Refer to the website for dimensions of the specific catalogue
reference selected
Installation Notes
• eLLK: Double sided tooled access mechanism also allows
diffuser to hang for ease of maintenance
• Enter the catalogue reference in the keyword search on the
homepage: www.coopercrouse-hinds.eu
• eLLK: Through wiring facility
• eLLK/nLLK are surface mount luminaires
• eLLM are post mount luminaires, 44mm dia pole socket in
the housing
• eLLB/D-RLF are recessed luminaires
• EXIT LED bulkheads are mains powered luminaires the EXIT N
LED versions are self contained emergency versions
• Where emergency converted fluorescent versions do not state
the emergency duration they can generally be selected as 1.5
or 3 hour duration upon installation
• Fluorescent supplied less lamp
Catalogue Numbers
Part Number
Description
Lamp
Rating
Emergency
Duration
Zone I: eLLK 92 Series Fluorescent Light Fittings
12265875111
Zone 1 eLLK 92018/18 2/6-2M luminaire 2x18W HF
2 x 18W
-
12266875111
Zone 1 eLLK 92036/36 2/6-2M luminaire 2x36W HF
2 x 36W
-
12267875111
Zone 1 eLLK 92058/58 2/6-2M luminaire 2x58W HF
2 x 58W
-
12260879111
Zone 1 eLLK 92018/18 Nib 2/6-2 M Emergency luminaire 2x18W HF
2 x 18W
1.5 or 3 hour
12261879111
Zone 1 eLLK 92036/36 Nib 2/6-2M Emergency luminaire 2x36W HF
2 x 36W
1.5 or 3 hour
Zone I: eLLM 92 Series Pole Mounted Fluorescent Fittings
12268875101
Zone 1 eLLM 92018/18 Pole Mount Luminaire 2x18W HF
2 x 18W
-
12269875101
Zone 1 eLLM 92036/36 Pole Mount Luminaire 2x36W HF
2 x 36W
-
12273879101
Zone 1 eLLM 92018/18 Nib Pole Mount Emergency Luminaire 2x18W HF
2 x 18W
3 hour
Zone I: eLLB 20 Series Recessed Fluorescent Fittings
12190218101
Zone 1 eLLB 20018/18 2/6-2 M Recessed Luminaire 2x18W HF white painted housing
2 x 18W
-
12190236101
Zone 1 eLLB 20036/36 2/6-2 M Recessed Luminaire 2x36W HF white painted housing
2 x 36W
-
12190258101
Zone 1 eLLB 20058/58 2/6-2 M Recessed Luminaire 2x58W HF white painted housing
2 x 58W
-
12190218102
Zone 1 eLLB 20018/18 Nib 2/6-2 M Recessed Emergency Luminaire 2x18W HF white painted housing
2 x 18W
3 hour
12190236102
Zone 1 eLLB 20036/36 Nib 2/6-2 M Recessed Emergency Luminaire 2x36W HF white painted housing
2 x 36W
3 hour
358
LIGHTING SOLUTIONS
CLS-CC2055 - March 2014
Industrial
Hazardous Area Luminaires
Catalogue Numbers
Part Number
Description
Lamp
Rating
Emergency
Duration
1 x 11W
1.5 hour
Emergency Exit Light Fitting: EE 11 Range
NOR000005160012
Zone 1/21 EE11PL 11W 1.5hr Self Contained Emergency Luminaire
Exit LED
12191000001
Zone EXIT mains LED Emergency bulkhead with (ARROW RIGHT) PR Pictogram
LED
-
12191000002
Zone EXIT mains LED Emergency bulkhead with (ARROW LEFT) PL Pictogram
LED
-
12191000003
Zone EXIT mains LED Emergency bulkhead with (ARROW DOWNWARDS) PU Pictogram
LED
-
12191000004
Zone EXIT mains LED Emergency bulkhead with clear cover (no Pictogram)
LED
-
Exit N LED
12191030001
Zone EXIT N 3hr Self Contained LED Emergency bulkhead with (ARROW RIGHT) PR Pictogram
LED
3 hour
12191030002
Zone EXIT N 3hr Self Contained LED Emergency bulkhead with (ARROW LEFT) PL Pictogram
LED
3 hour
12191030003
Zone EXIT N 3hr Self Contained LED Emergency bulkhead with (ARROW DOWNWARDS) PU Pictogram
LED
3 hour
12191030004
Zone EXIT N 3hr Self Contained LED Emergency bulkhead with clear cover (no Pictogram)
LED
3 hour
Zone 2 and 21 - nLLK 08 Series Fluorescent Light Fittings: Bi-Pin
13465218021
Zone 2/21 nLLK 08018/18 2/6-2M luminaire 2x18W HF
2 x 18W
-
13465136021
Zone 2/21 nLLK 08036 2/6-2M luminaire 1x36W HF
1 x 36W
-
13465236021
Zone 2/21 nLLK 08036/36 2/6-2M luminaire 2x36W HF
2 x 36W
-
13465158021
Zone 2/21 nLLK 08058 2/6-2M luminaire 1x58W HF
1 x 58W
-
13465258021
Zone 2/21 nLLK 08058/58 2/6-2M luminaire 2x58W HF
2 x 58W
-
1.5 hour
Emergency Version
13470218131
Zone 2/21 nLLK 08018/18 N 2/6-2M 1.5hr Emergency luminaire 2x18W HF
2 x 18W
13469218131
Zone 2/21 nLLK 08018/18 N 2/6-2M 3hr Emergency luminaire 2x18W HF
2 x 18W
3 hour
13470236131
Zone 2/21 nLLK 08036/36 N 2/6-2M 1.5hr Emergency luminaire 2x36W HF
2 x 36W
1.5 hour
13469236131
Zone 2/21 nLLK 08036/36 N 2/6-2M 3hr Emergency luminaire 2x36W HF
2 x 36W
3 hour
-
Zone 22 - D22-LLK 98 Series Fluorescent Light Fittings: Bi-Pin - Standard
13465218021
Zone 22 D22 nLLK 98018/18 2/6-2M Luminaire 2x18W HF
2 x 18W
13465236021
Zone 22 D22 nLLK 98036/36 2/6-2M Luminaire 2x36W HF
2 x 36W
-
3465258021
Zone 22 D22 nLLK 98058/58 2/6-2M Luminaire 2x58W HF
2 x 36W
-
Bi-Pin - CG-S
13465218922
Zone 22 D22 nLLK 98018/18 2/6-2M Luminaire 2x18W HF with CEAG CG-S module
2 x 18W
-
13465236922
Zone 22 D22 nLLK 98036/36 2/6-2M Luminaire 2x36W HF with CEAG CG-S module
2 x 36W
-
13465258922
Zone 22 D22 nLLK 98058/58 2/6-2M Luminaire 2x58W HF with CEAG CG-S module
2 x 58W
-
Emergency Version
13470218031
Zone 22 D22 nLLK 08018/18 N 2/6-2M 1.5hr Emergency luminaire 2x18W HF
2 x 18W
1.5 hour
13470236031
Zone 22 D22 nLLK 08036/36 N 2/6-2M 1.5hr Emergency luminaire 2x36W HF
2 x 36W
1.5 hour
D-RLF 250 Series Recessed Light Fittings - Twin Lamps
12283218002
Zone 22 D22-RLF25018/18 2/5-2M Recessed Luminiare 2x18W HF white painted housing
2 x 18W
-
12283236002
Zone 22 D22-RLF25036/36 2/5-2M Recessed Luminiare 2x36W HF white painted housing
2 x 36W
-
12283258002
Zone 22 D22-RLF25058/58 2/5-2M Recessed Luminiare 2x58W HF white painted housing
2 x 58W
-
D-RLF 250 Series Recessed Light Fittings - Triple Lamps
12283336012
Zone 22 D22-RLF250336 2/5-2M Recessed Luminiare 3x36W HF white painted housing
2 x 36W
-
12283358012
Zone 22 D22-RLF250358 2/5-2M Recessed Luminiare 3x58W HF white painted housing
2 x 58W
-
D-RLF 250 Series Recessed Light Fittings - Quadruple Lamps
12283418012
Zone 22 D22-RLF250418 2/5-2M Recessed Luminiare 4x18W HF white painted housing
4 x 18W
-
12283436012
Zone 22 D22-RLF250436 2/5-2M Recessed Luminiare 4x36W HF white painted housing
4 x 36W
-
12283458012
Zone 22 D22-RLF250458 2/5-2M Recessed Luminiare 4x58W HF white painted housing
4 x 58W
-
For further details, please refer to Eaton’s Crouse-Hinds business website, www.coopercrouse-hinds.eu
(Enter the catalogue reference in the keyword search on the homepage)
A useful and informative document covering the detail of hazardous area requirements, definitions and product markings is
downloadable from Eaton’s Crouse-Hinds business website at www.coopercrouse-hinds.eu/en/principles-of-explosion-protection.
LIGHTING SOLUTIONS
CLS-CC2055 - March 2014
359
Download