“We have full confidence in the quality of TPS products and services. We recommend TPS for any project where surge protection is required”. Warranty -Zbigniew Glowacki, M.Sc. Manager Electrical Engineering Many SPDs are not warranteed for large transients or surges of any kind. Make sure to get a comprehensive written warranty statement before any purchase. Total Protection Solutions’ Service Track SPDs has a 30 Year Free Replacement Warranty. We will replace any SPD that fails due to a defect in material, workmanship or any electrical anomaly including direct lightning… Need we say more? Do you have reliable surge protection? Distributed by: International Innovative Systems Box 23032, Stn Mall P.O. Sault Ste. Marie, ON P6A 6W6 phone (800)853-8265 fax (705)759-7083 email info@tpscanada.ca www.tpscanada.ca International Innovative Systems has been providing reliable Power Quality solutions since 1984, merging over 75 years of field experience with the quality of Total Protection Solutions; a proven line of innovative Surge Protection Devices (SPDs). Application R.O.I. You name the application and we will show you a proven solution that will save your facility costly down time, unnecessary repairs, a fast return on investment and life cycle savings that will pay dividends for years to come. Payback / Breakeven • A comprehensive Return On Investment analysis is available for all applications. • The cost of T.P.S. surge Protection in most applications is less than 1% of the capital cost of equipment • TPS™ systems have warranted lifespan of 30 years LET I.I.S. SELECT THE RIGHT PRODUCT FOR YOU Protect the following: Industrial • MCC and Gen-Sets: Protection from Lightning, Grid Switching and poor power quality. • Drives-VFD’s: Lock ups and Failures • PLC’s, HMI’s, Robotics: Reboots and board failures • CNC Machines: Inaccuracies and lock ups Commercial • Electronic and LED lighting: Premature ballast and driver failure • H.V.A.C.: Motor and control board failures • Alarm and Telephone systems: False alarms and system failures • P.O.S. and Computers: Lock ups and failures Institutional • MRI, X-RAY, CAT Scan: Equipment failure and poor imaging • Backup Generator and Auto Transfer: Equipment failure during Gen-Set testing • Electronic and LED lighting: Premature ballast and driver failure • Nurse Call and Alarms: False Tripping and blown boards. Water and Waste Water • Main Incoming: Protection from Lightning, Grid Switching and poor power quality. • SCADA and PLC’S: Lock ups, Failures and data interruption • U.V. Lighting: Premature Ballast Failure • Motors and VFD’s: Failures LET I.I.S. SELECT THE RIGHT PRODUCT FOR YOU SPD Protection Benefits • Extended Equipment Life • Increased Reliability • Dramatically Reduce Electrical Maintenance & Repair • Reduction in Future Capital Equipment Replacement Investment • TPS contributes to GREEN and sustainability goals • Dramatically Reduce Downtime “The return on investment was realised within months. We have experienced many high-energy thunder storms in the past year-and-a-half with no controller down-time.” Lifecycle Savings • Analysis relative to dollar savings over useful life of investment • Assures real understanding of potential savings on long life projects • TPS™ 30-year unlimited free replacement warranty justifies lifecycle of 30 years First Cost / Low Bid • Used by many companies and engineers to purchase SPD • Many specs require SPD to be integrated into switchgear & sub-panels • Results in project design driven by lowest cost, regardless of quality or performance • Low cost SPD’s leave your facility at risk from damaging surges. Yet project designs that are driven by Low Bid often compromise quality and performance. Work with your TPS representative to achieve your design requirements. Schools • MCC and Gen-Sets: Protection from Lightning, Grid Switching and poor power quality. • T-5/T-8 lighting: Premature Ballast Failure • Smart Boards and Computers: Reboots and board failures • Fire Alarm protection Warranty Agriculture • Farming, Greenhouses and Hutterite complexes: Barn automation, Laundry, Main Incoming, Kitchen • Ventilation Systems: Reboots and board failures • R.F.I.D.: Lost counts, board failures Many SPDs are not warranted for large transients or surges of any kind. Make sure to get a comprehensive written warranty statement before any purchase. Residential • Main Breaker Panel: Protection from Lightning, Grid Switching and poor power quality. • Coaxial and Telephone: Flat screen T.V.’s and Computers • Up Scale Homes: Home Theatres, Security Gates, Cameras, Home Automation -Bruce Abram City of London, Ontario HOW WE COVER YOUR INVESTMENT Total Protection Solutions’ Service Track SPDs has a 30 Year Free Replacement Warranty. We will replace any SPD that fails due to a defect in material, workmanship or any electrical anomaly including direct lightning… Need we say more? Mining • Drives-VFD’s: Lock ups and Failures • Medium Voltage up to 4160 volts 1 2 “We knew that TPS was focused on ensuring that our needs as a customer were met. The benefits of site inspections are invaluable to us...” Products -Mark Presti, P. Eng Manager of Technical Trades - Niagara Region For details and install instructions on these products, visit the “Products” tab at www.TPSCanada.ca ServiceTrack LowProfile TransTrack2 PanelTrack LoadTrack ComTrack ServiceTrack models are the choice for main service, distribution panel, and branch panel applications. Compact design offers easy installation. The optional enhanced transient filter allows you to extend your equipment life and reliability. Low Profile models have a minimal footprint which optimizes the installation and offer performance advantages with in-wall flush mount capability. The best choice for sub-panel and critical load applications with the best enhanced transient filter (ETF) in the industry. TransTrack2 models protect facilities and equipment against harmful effects of lightning strikes and internally generated electrical transients. Individually fused MOVs provide superior protection and continious operation. Low profile, ultra compact footprint and optional flush plate offer design in-wall flush mount capability. PanelTrack models protect facilities and equipment against the harmful effects of lightning strikes and internally generated electrical transients. LoadTrack models provide surge protection against harmful transient voltages that exceed the nominal operating voltage of AC and DC critical dedicated control loads. ComTrack models are the most reliable surge protective devices for data and communication applications. Applications • Branch Panels • Distribution Panels • O.E.M. panels and power supplies Applications • Electrical Control Panels • O.E.M. panels and power supplies Applications • Flush Mount Panels • Branch Panels • Critical Load Centre Features • Includes pre-wired pigtail conductors to streamline installation • Compact Footprint Allows Easy and Flexible Installation • Optional DIN-rail mounting clips • Optional flush mount cover (PKS-FMP) • Dual Component Level Fusing provides over-current plus thermal protection for added safety • cUL Listed for use in Canada as 3rd Edition, Type 2 • 10-Year Free Replacement Warranty Applications • Main Service • Switchgear • Distribution Panels • Branch Panels • Critical Load Centre Features • 80kA to 400kA per Phase Maximum Surge Current Rating • Compact Footprint Allows Easy and Flexible Installation • Internal Audible Alarm • Component Level Fusing (CLF) and Enhanced Transient Filter Options • Fail Safe Design (CLF Option) • Disconnect Switch (Fused or NonFused) Options • NEMA 4 Steel Enclosure • UL 1449 3rd Edition, Type 1 for Type 1 & 2 locations, UL 1283 and cUL Listed • NEMA LS-1 Compliant - Tested and Verified at Third Party Independent Lab • Enhanced Transient Filter (ETF) • 30-Year Free Replacement Warranty 3 Applications • Flush Mount Panels • Branch Panels • Critical Load Centre Features • 80 and 120kA per Phase Maximum Surge Current Rating (for 120/240V 1φ, 120/208V 3φ, 277/480V 3φ) • Dual Component Level Fusing • Fail Safe Design • Width of 4” Allows Units to Fit Between Adjacent Panel Boards • Depth of 3.5” Allows for Flush Panel Mount Installation • Flush Mount Cover Plate Available • UL 1449 3rd Edition, Type 1 for Type 1 & 2 locations, UL 1283 and cUL Listed • NEMA LS-1 Compliant - Tested and Verified at Third Party Independent Lab • Enhanced Transient Filter (ETF) • 30-Year Free Replacement Warranty Features • Features 65kA and 100kA per Phase Maximum Surge Current Rating • Compact Footprint Allows Easy and Flexible Installation • Status indicator lights (LED) • Component Level Fusing (CLF) and Enhanced Transient Filter • Fail Safe Design - 200 kAIC short circuit current rating • Optional flush-mount plate for recessed panel applications • NEMA 4 Steel Enclosure • UL 1449 3nd Edition Listed, Type 1 for Type 1 & 2 locations, UL1283 Listed, & cUL Listed • Enhanced Transient Filter (ETF) • 25 -Year Free Replacement Warranty Features • Ideal for protecting the PLC’s, Building management systems, OEM & systems integration controls and other microprocessorbased loads • Compact, fail-safe design allows flexible installation • Dual Component-Level Fusing (CLF) standard, Enhanced Transient Filter (ETF) standard • 15-Year Free Replacement Warranty “Our products solve many of the electrical problems experienced by commercial and industrial facilities. The resulting Total Protection System will dramatically improve the operating efficiency and reliability of the electrical system.” Features Provides quality protection for… • Telephone Lines – (C62.36 Test Methods; C62.43 Applications; C62.64 Specifications) Protects All Major Applications, Including Dial-up, DSL, T1/E1, DDS, Leased Lines, & ISDN and Protects up to 25 Pairs • Data/Signal Lines - Utilizes MultiStage Hybrid Suppression Technologies to Provide the Highest Surge Rating (10kA per Wire) and Data Rate (10Mbps) • Coaxial Lines – Wide Range of Available Configurations; Choose from F & BNC • Multiple Termination (Terminal Block, RJ Connectors, Punchdown Block) and Mounting Methods (Bracket Style, Din-Rail, Metal Conduit) to Choose From • UL 497A Listed • 10-Year Free Replacement Warranty 4 Our commitment to the environment is to keep your equipment running in your factory and out of the landfill. Total Protection Solutions Total FACILITY protection is what we do best A Total Protection Solution® is the best way to protect your facility. Protect your entire facility and see significant improvement in maintenance costs, reliability and downtime. The Total Protection Solutions® complete line of AC power and telecommunications surge protection devices incorporate the next generation of power protection technology. Our skilled team of professionals will help you choose products that will work most effectively with your applications and within your budget requirements. With more than 60 years experience, it’s something we do well for you. Building infrastructure and heavy equipment benefit from a secondary level of protection. On the manufacturing or assembly line, protect all equipment, computer controls, and lighting controls. The main service entrance is the first line of defense. SPD TROUGH SPD SPD SPD SPD SPD DISTRIBUTION PANEL BRANCH PANEL MAIN SERVICE TRANSFORMER CONTROL PANEL FIRE ALARM PANEL SPD MCC SPD Front office telecom, data entry and exit points are critical, as are pointsof-use equipment like computers, server rooms and building controls. SPD • Medium Exposure* • Distribution Panels • Branch Panels HVAC SPD Remember to protect your telecommunication and data systems along with your AC Power Distribution System. SPD * Note: TELECOM • Low Exposure* • Branch Panels • Outlet/Load 5 • High Exposure* • Main Service PLC IEEE defines exposure levels according to the likelihood of damage due to surges/transients from catastrophic external events (i.e. lightning, utility faults, etc.) 6 Value Added Services “The service provided by TPS Canada was professional, reliable and consistent. Their product offerings cover a broad range of applications and we have found them to be of the utmost quality.” -Matt Dreszel Genivar Consultants STRATEGIES FOR FACILITY-WIDE PROTECTION TPS adds value Do I Need Protection? 1) International Innovative Systems will consult with engineers on new buildings and do site surveys for existing facilities and recommend suppression strategies that achieve the customer’s goals. Some daily frustrations of doing business can be symptoms of a dirty power supply. Do you have some of these issues: • Computers or controllers losing memory during operations? • Telephone systems disconnect calls for no apparent reason? • Replacing failed or damaged circuit boards? • Would you like more reliable lightning protection? • Replacing too many bulbs and ballasts? • Would you like to extend the life of your electrical equipment? • Interested in better reliability? • Does your company focus on improved productivity? • Concerned about equipment downtime? • Would you like to reduce your maintenance expense? 2) Upon installation our representatives can approve installations. 3) Years after the installations, our warranty support can assist with trouble-shooting if products self-sacrifice in the course of protecting loads. If you answered “yes” to any of these questions, we invite you to have your facility analyzed by our experienced team of experts. Even if you already have surge suppression products in place, our skilled team can give your system a check-up and identify any areas needing improvement. Call today, and let us show you how our surge protection programs can mean total protection for your operation. For power quality and performance, backed by an unprecedented warranty and invaluable field experience, choose Total Protection Solutions®. 7 Discuss your facility layout and your priorities with a TPS representative. Your solutions will be customized to fit your needs and budget. 8 “We were experiencing fluctuations in the power that was affecting our drive areas, causing equipment replacement... there was an abundance of voltage anomalies on the system. Since the installation (of TPS surge suppression units) we have had no issues related to our power quality in this area.” Suppression Design - Traian Berescu Toyota Motor Manufacturing Canada Inc STRATEGIES FOR FACILITY-WIDE PROTECTION Electronic failure inevitable Surge Only Surges dampened but not eliminated Surge & Power Filtering Clean Power Traditional loads with no microprocessor Before and after TPS suppression PLC Waveform components have traditional protection – fuses and breakers. Transient overvoltages are not attenuated. This “No Protection” situation is represented in the first line of Figure A 500 Time Line 400 300 200 Threshold suppression designs begin to attenuate voltage excursions at a set point above the sine wave. The Enhanced Tracking suppression (ETF) design adds a filter component to the suppression circuits. This attenuates transients inside the power envelope. An actual trace of a ETF suppressor attenuating a 2,000 volt impulse (ANSI/IEEE A1 Ringwave) 100 Voltage No Protection 0 Series1 1 5 9 13 17 21 25 29 33 37 41 45 49 53 57 61 65 69 73 77 81 85 89 93 97 101 105 109 113 117 121 125 129 -100 -200 -300 -400 -500 Transient Activity Prior to TVSS Installation No Transient Activity after TVSS Installation Here is a sampling of a logic circuit before and after the application of a TPS suppressor. This automated machinery operated as intended for months, despite constant exposure to repetitive 300+ volt events. Eventually, however, these transients caused logic disruption and catastrophic failure with significant downtime costs. We can help you solve problems and improve productivity with proper application of TPS surge suppression devices. (The phenomena of Type 1 damage – logic disruption - is discussed in detail in IEEE Standard 1100-2005 4.4.5.1) These electron microscope images illustrate Type-III damage resulting from overvoltages reaching the integrated circuitry. (The phenomena of Type-III damage - hardware destruction - is discussed in detail in IEEE Standard 1100-2005 4.4.5.3) Note that the impulse was attenuated well within the sine wave. ANSI/IEEE terms this 29 volt remnant the “Measured Limited Voltage”. Where do Transients Come From? TPS provides customers with full disclosure of the performance characteristics of all its products. This is critical information for suppression strategies which will maximize performance value of a customer’s surge suppression investment. Measured Limited Voltage values are provided for all modes, on all products, for all exposure levels (A, B and C) of a facility. Common Misconception The majority of voltage transients originate outside the user’s facility. Reality High energy sources, like lightning strikes, grid switching & other utility faults typically account for only 10% - 15% of all transients recorded. Inside the facility Outside the facility 15% 85% All information is based on ANSI/IEEE 62.41 standardized testing waveforms. 9 10