TM PRELIMINARY DATA SHEET ISO13286: DC to 8 GHz Hermetic GaAs IC SPDT Absorptive Switch Features CBL Wideband frequency range: DC to 8 GHz RF1 Isolation: 50 dB @ 4 GHz Low Loss: 1.5 dB @ 4 GHz 50 Absorptive CBL High reliability Class B and S screening available RFC Description 50 The ISO13286 is a GaAs pHEMT non-reflective, high-performance, low-loss switch. CBL RF2 Y1399 The ISO13286 uses hermetic surface-mount technology (SMT) for defense and satellite applications. The device can be supplied and tested to the screening requirements of MIL-PRF-38535 Class B and S, in addition to the required QCI. A B Figure 1. ISO13286 Block Diagram A functional block diagram of the ISO13286 is shown in Figure 1. The ISO13286 device package and pinout are shown in Figure 2. Pin assignments and signal descriptions are shown in Table 1. RFC Table 1. ISO13286 Pin Descriptions Pin 2 RF1 1 3 4 5 6 RF2 7 Name Description 1 RF2 RF output 2 2 RFC RF input 3 RF1 RF output 1 4 GND Ground 5 A Control voltage A 6 B Control voltage B 7 GND Ground Y1400 GND A B GND Figure 2. ISO13286 Pinout (Top View) Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 203325A • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 31, 2015 1 PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH Electrical and Mechanical Specifications The absolute maximum ratings of the ISO13286 are provided in Table 2. Electrical specifications are provided in Tables 3 and 4. The truth table is shown in Table 5. Typical performance characteristics of the ISO13286 are illustrated in Figures 3 through 10. Table 2. ISO13286 Absolute Maximum Ratings (Note 1) Parameter Minimum Maximum Units –7.5 +1.0 V +26 dBm Storage temperature –65 +150 C Operating case temperature –55 +125 C Control voltages (A and B) RF input power Junction temperature Operating frequency 0.03 +150 C 8.00 GHz Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. ISO13286 Recommended Operating Conditions Parameter Symbol Switching characteristics: Rise, fall Test Condition Min Typical Max 10/90% or 90/10% RF 5 ns On/off 50% control to 90/10% RF 15 ns Video feedthrough TRISE = 3 ns, measurement bandwidth = 500 MHz 25 mV +26 dBm +24 dBm –60 dBm Input power for 1 dB compression OP1dB 0.5 to 4.0 GHz Input power for 0.1 dB compression OP.1dB 0.5 to 4.0 GHz nd 2 harmonic 2fo fO = 2400 MHz, PIN = –15 dBm Third order intercept point IP3 For 2-tone input power, +8 dBm/tone, 1 MHz spacing, VCTL = 0/5 V, 0.7 to 3.0 GHz Control voltages VCTL Low VCTL High Control currents VCTL Low VCTL High –5 V/–7 V dBm +46 –0.2 –5 0 –7 4 100/200 Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 2 Units July 31, 2015 • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203325A V V μA μA PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH Table 4. ISO13286 Electrical Specifications (Note 1) (VCTL = 0 V/3 V, VDD = 5 V, TOP = +25 C, PINPUT = 0 dBm, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition CW insertion loss IL 0.1 to 2.0 GHz 2.0 to 4.0 GHz 4.0 to 6.0 GHz 6.0 to 8.0 GHz Isolation Iso 0.1 to 2.0 GHz 2.0 to 4.0 GHz 4.0 to 6.0 GHz 6.0 to 8.0 GHz Return loss (insertion loss state) (Note 2) RL Return loss (isolation state) (Note 2) Insertion loss settling time Min Typical Max Units 0.8 0.8 2.5 2.5 1.10 1.5 3.0 3.0 dB dB dB dB 60 50 45 45 dB dB dB dB 0.1 to 2.0 GHz 2.0 to 4.0 GHz 4.0 to 6.0 GHz 6.0 to 8.0 GHz 22 20 12 10 dB dB dB dB RL 0.1 to 2.0 GHz 2.0 to 4.0 GHz 4.0 to 6.0 GHz 6.0 to 8.0 GHz 12 15 15 13 dB dB dB dB ΔIL Insertion loss in dB measured @ 1 μs (referenced to a rising 10% RF level on J1 & J2) minus the CW insertion loss in dB. Freq = 2 GHz, TOP = +25 °C, VCTL = 5 V, pulse width = 1.15 ms, 50% duty cycle. 0.4 dB 50 45 40 40 Note 1: Performance is guaranteed only under the conditions listed in this table. Note 2: Lower frequency return loss is dependent on DC blocks. Table 5. Truth Table Control Input B Signal Path State A RFC to RF1 RFC to RF2 High Low ON OFF Low High OFF ON Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 203325A • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 31, 2015 3 PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH Typical Performance Characteristics (VCTL = 0 V/5 V, Top = +25 C, PINPUT = 0 dBm, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted) OP0.1dB vs Frequency OP1dB vs Frequency 30 29 29 28 28 27 27 O P1d B (dB m ) 26 RF1 25°C RF1 125°C 25 RF1 -55°C RF2 25°C 24 O P0.1dB (dB m ) 30 26 RF1 25°C RF1 125°C 25 RF1 -55°C RF2 25°C 24 RF2 125°C RF2 125°C RF2 -55°C 23 RF2 -55°C 23 22 22 21 21 20 20 0.5 1.0 1.5 2.0 2.5 3.0 3.5 0.5 4.0 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Frequency (GHz) Frequency (GHz) Figure 4. OP0.1dB vs Frequency Figure 3. OP1dB vs Frequency Insertion Loss vs Frequency IP3 vs Frequency 0.0 60 -0.5 55 -1.0 -1.5 -2.0 RF1 25°C 45 RF2 25°C RF1 125°C 40 RF2 125°C S 2 1 (d B ) IP3 (dB m ) 50 RF1 25°C RF2 25°C -2.5 RF1 125°C RF2 125°C -3.0 RF1 -55°C RF1 -55°C RF2 -55°C 35 RF2 -55°C -3.5 -4.0 30 -4.5 -5.0 25 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Frequency (GHz) Figure 5. IP3 vs Frequency 4.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.5 8.0 Figure 6. Insertion Loss vs Frequency Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 4 7.0 Frequency (GHz) July 31, 2015 • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203325A PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH Typical Performance Characteristics (VCTL = 0 V/5 V, Top = +25 C, PINPUT = 0 dBm, Characteristic Impedance [Zo] = 50 Ω, Unless Otherwise Noted) Return Loss (On State) vs Frequency Isolation vs Frequency 0 0 -5 -10 -10 -20 RF1 |S11| 25°C RF2 |S11| 25°C -15 -30 RF1 |S22| 25°C -20 -40 RF2 25°C RF1 125°C -50 RF2 125°C S 11 (d B ) S 2 1 (d B ) RF1 25°C RF2 |S22| 25°C RF1 |S11| 125°C -25 RF2 |S11| 125°C RF1 |S22| 125°C -30 RF2 |S22| 125°C RF1 -55°C -60 RF2 -55°C RF1 |S11| -55°C -35 RF2 |S11| -55°C -70 -40 -80 -45 RF1 |S22| -55°C RF2 |S22| -55°C -50 -90 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 0.0 8.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Frequency (GHz) Frequency (GHz) Figure 8. Return Loss (On State) vs Frequency Figure 7. Isolation vs Frequency Output to Output Isolation Return Loss (Off State) vs Frequency 0.0 0 -10.0 -5 -20.0 -10 RF1 |S11| 25°C RF2 |S11| 25°C -15 -30.0 S 2 2 (d B ) RF2 |S22| 25°C RF1 |S11| 125°C -25 RF2 |S11| 125°C R F 1 -R F 2 (d B ) RF1 |S22| 25°C -20 RF1-RF2 25°C -40.0 RF2-RF1 25°C RF1-RF2 125°C -50.0 RF2-RF1 125°C RF1 |S22| 125°C -30 RF2 |S22| 125°C RF1 |S11| -55°C -35 RF2 |S11| -55°C -40 RF1 |S22| -55°C RF2 |S22| -55°C -45 RF1-RF2 -55°C -60.0 RF2-RF1 -55°C -70.0 -80.0 -90.0 0.0 -50 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Frequency (GHz) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 Frequency (GHz) Figure 10. Output to Output Isolation Figure 9. Return Loss (Off State) vs Frequency Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 203325A • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 31, 2015 5 PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH Evaluation Board Description Package Dimensions The ISO13286 Evaluation Board is used to test the performance of the ISO13286 switch. An Evaluation Board schematic is shown in Figure 11. An assembly drawing for the Evaluation Board is shown in Figure 12. A suggested driver circuit is shown in Figure 13. Package dimensions for the ISO13286 are shown in Figure 14. Figure 15 shows the pad locations. J3 C3 RFC 100pF 2 U1 RF2 RF2 100pF GND B 1 7 4 A ISO13286 100pF GND RF1 J2 C2 RF1 5 3 RFC C1 6 J1 J4 1 2 3 4 CON4 ts569 Figure 11. ISO13286 Evaluation Board Schematic Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 6 July 31, 2015 • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203325A PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH J1 RF1 Isolink 2015 C1 J4 ISO13286EVB Rev2 U1 C3 2BVE68231OSI 1 C2 J2 RF2 J3 RFC Y1976 Figure 12. ISO13286 Evaluation Board Assembly Diagram J3 J1 A 1 B J4 D1 2 1 CON1 1 U1A 54C04 ZENER3 3 U1B 4 54C04 R1 10 kΩ J2 1 CON1 –5VDC ts568 Figure 13. ISO13286 Suggested Driver Circuit Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 203325A • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 31, 2015 7 PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH 0.135 0.045 0.010 0.345 ±0.010 0.30 0.215 0.130 0.130 0.005 ±0.002 0.065 Max 0.260 0.33 0.385 ±0.010 Y1096 Figure 14. ISO13286 Package Dimensions 0.016 x 0.030 3 Places 172.5 0.100 CL −0.0225 −0.100 −0.1725 0.020 x 0.030 4 Places 0.175 0.125 0.0675 0.0225 −0.0225 −0.0675 −0.125 −0.175 CL ts570 Figure 15. Pad Locations for the ISO13286 Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 8 July 31, 2015 • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • 203325A PRELIMINARY DATA SHEET • ISO13286: SPDT ABSORPTIVE SWITCH Ordering Information Model Name ISO13286: DC to 8 GHz Low Loss SPDT Manufacturing Part Number ISO13286 Copyright © 2015 Isolink, Inc. All Rights Reserved. Information in this document is provided in connection with Isolink, Inc. (“Isolink”) products or services. These materials, including the information contained herein, are provided by Isolink as a service to its customers and may be used for informational purposes only by the customer. Isolink assumes no responsibility for errors or omissions in these materials or the information contained herein. Isolink may change its documentation, products, services, specifications or product descriptions at any time, without notice. Isolink makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Isolink assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Isolink products, information or materials, except as may be provided in Isolink Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. ISOLINK DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. ISOLINK SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Customers are responsible for their products and applications using Isolink products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Isolink assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Isolink products outside of stated published specifications or parameters. Isolink is a trademark of Isolink Inc. in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Isolink, Inc. • Phone [408] 946-1968 • Fax [408] 946-1960 • sales@isolink.com • www.isolink.com 203325A • Isolink Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 31, 2015 9