DTR Transformer Tap Changer Controller Automatic voltage regulation, analysis, and control functions for transformer applications. Applications Monitoring and Metering ■ Control power transformer OLTCs to regulate voltage ■ I, V, P, Q, cos j, frequency measurement ■ Transformer OLTC position Integrated Systems ■ Event recording ■ Counter of the tap position increases and decreases for rise and lower operations of tap changer ■ Protection and Control ■ Automatic voltage regulator ■ Automatic/manual operation User Interfaces ■ Three setting tables ■ ■ Configurable inputs and outputs Rear communication port (plastic or glass fiber optic, RS232 or RS485) ■ BCD format inputs to detect tap changer position ■ RS232 port, faceplate accessible ■ GE-NESIS Windows® based programming software ■ Mimic for increasing/decreasing commands and tap displaying ■ Graphic display and keypad ■ ModBus®, M-Link, and M-Link Plus communications protocols ■ DDS system compatible ■ Control pulse outputs GE Multilin 1 DTR Transformer Tap Changer Controller DESCRIPTION CONTROL The transformer tap changer controller DTR controls automatically the transformer on load tap changer, so that the power supply voltage is practically constant, independently from the load. In order to achieve this, the DTR is able to increase and decrease the OLTC in the power transformer. Operation The DTR can be applied to any existing tap changer, as its settings and operation ranges, as well as its inputs and outputs, are fully compatible with all the OLTC available in the market. The DTR has been designed using the same hardware architecture as the DDS protection and control system. This means that, besides being a powerful individual element, the DTR is completely compatible with the system, and can be fully integrated in a substation. The DTR also provides analysis and control functions, such as event recording. The internal memory allows storing up to 165 events. It also includes measuring functions for I, V, frequency, etc. As all the units part of the DDS family, the DTR provides easily configurable inputs and outputs. The user can program these inputs and outputs by means of userfriendly software programs, part of GE-NESIS (GE-INTRO, GE-LOCAL). This software package is Windows® based and it is the same for all the DDS family. 2 The DTR is used to maintain a constant voltage level at feeders busbar. The unit gives commands to increase and decrease the transformer OLTC. As these differences in the tap position are usually discrete, the DTR allows the user to set the percentage of change between taps. In addition, a time delay is provided by setting, to allow matching the OLTC time required to change from one tap to the closest next. Automatic/Manual Operation Using one of the configurable digital inputs, the DTR can receive an order for automatic or manual operation. Manual operation has priority over automatic, in order to avoid performance failures in the case of manual operations. This command can also be sent to the unit by means of the communications software, or the MMI. MONITORING AND METERING Measures The voltage regulator DTR displays instantaneous values of I, V, P and Q (three-phase), frequency and cos ϕ values. Event Recorder 165 events are recorded in nonvolatile EEPROM memory. Date and time (1 ms resolution), type of event, voltage and current, and a relay status snapshot are stored. Digital Inputs and Outputs The DTR system has 42 digital inputs and 22 outputs. These I/Os can be configured by the user by means of GE-INTRO configuration software. Blockings The transformer tap changer controller DTR blocks its operation in case that voltage falls below user defined limits, (undervoltage blocking), and also when voltage or current exceeds another user defined limit (overvoltage or overcurrent blocking). Settings The unit provides three setting tables. The user can move from one table to another using a digital input or through communications. This feature allows the use of different settings in different system situations to better maintain the actual system needs of security, etc. www.GEindustrial.com/Multilin DTR Transformer Tap Changer Controller Typical Wiring B4 I1 A1 I5 A2 I5 A7 V A8 V N1 O1 N2 02 N3 O3 N4 O4 GE Power Management DTR Automatic Voltage Regulator I1 I2 TAP 1 (BCD) TAP 2 (BCD) I3 I4 I5 I6 TAP 3 (BCD) TAP 4 (BCD) TAP 5 (BCD) TAP 6 (BCD) INCREASE COMMAND O1 DECREASE COMMAND O2 AUTOMATIC O3 MANUAL O4 I7 STOP COMMON I10 I11 I12 I13 INTERLOCKING 2 SYSTEM READY PROGRAMMABLE OUTPUTS INTERLOCKING 1 REGULATOR ALARM INPUTS 2 I8 I9 I14 COMMON I15 I16 INPUTS 3 I17 I18 I19 I20 I21 COMMON I22 I23 INPUTS 4 I24 I25 I26 I27 I28 COMMON I29 I30 I31 I32 INCREASE DECREASE AUTOMATIC MANUAL I33 I34 I35 STOP COMMON I36 I37 TABLE 1 TABLE 2 I38 I39 INPUTS 5 J9 K9 J10 K10 J11 K11 J12 K12 L1 M1 L2 M2 L3 M3 L4 M4 g O5 O6 STOP COMMAND O7 COMMAND NOT EXECUTED O8 IRREGULAR TAP CHANGE O9 UNDERVOLTAGE O10 OVERVOLTAGE O11 OVERCURRENT O12 LOCAL O13 REMOTE O14 SUCCESSIVE OPERATIONS O15 EXCESSIVE OPERATIONS O16 BCD 1 TAP O17 BCD 2 TAP O18 BCD 3 TAP O19 BCD 4 TAP O20 BCD 5 TAP O21 BCD 6 TAP O22 Q5 P5 Q6 P6 Q7 P7 Q8 P8 Q9 P9 Q10 P10 L5 M5 L6 M6 L7 M7 L8 M8 L9 M9 5 L10 M10 L11 M11 L12 M12 N5 O5 N6 O6 N7 O7 N8 O8 N9 O9 N10 O10 N11 O11 N12 O12 RTU INPUTS J1 K1 J2 K2 J3 K3 J4 K4 J5 K5 J6 K6 J7 K7 J8 K8 G A12 CONTROL POWER INPUTS 6 P1 Q1 P2 Q2 P3 Q3 P4 Q4 D11 C11 Q11 P11 INPUTS 1 I1 VOLTAGE B3 CURRENT INPUTS CONTROL POWER SUPPLY I40 I41 I42 COMMON EN DTR CON.cdr www.GEindustrial.com/Multilin 3 DTR Transformer Tap Changer Controller Technical Specifications Ordering METERING Frequency: Nominal Phase Current: Nominal Voltage: Auxiliary Voltage: 50/60 Hz 1 or 5 A 100/√3 - 220/√3 VAC 48-125 VDC, ±20% 110-250 VDC, ±20% COMMUNICATIONS Local Communication: LCD alphanumeric display with two lines of 16 characters per line; 20 button frontal keypad Remote Communication (local or remote PC and communications net): Mode: half duplex Speed: 1,200 to 115,000 bps Physical media: RS232 (ports 1 and 2) RS485 (port 2 optional) Plastic Fiber Optic (port 2 optional): Type of connector: HFBR-4516 Power supplied: 8 dBm Receptor’s sensitivity: -39 dBm Wave length: 660 nm Glass Fiber Optic (port 2 optional) Type of connector: STA Power supplied: 17.5 dBm Receptor’s sensitivity: -24.5 dBm Wave length: 820 nm Synchronization: IRIG-B • DB9 connector for RS232 ports on the front (1) and on the rear (2). • DB9 connector for RS232 port on the rear (3), with 1 mm plastic fiber optic or 50/125 glass fiber optic option. INPUTS THERMAL CAPACITY Current Circuits: Continuously: During 3 Sec: During 1 Sec: Voltage Circuits: Continuously: During 1 Min: BURDENS Current Circuits: DTR 1 * 0 * * 000 * 00 A DTR 0 1 2 3 0 2 M D G H Automatic Voltage Regulator RS232 communications interface Plastic fiber optic + RS232 communications interface Glass fiber optic + RS232 communications interface RS485 communications interface P1, P2: M-Link protocol P1: M-Link protocol; P2: ModBus® RTU protocol Spanish language English language 48 - 125 VDC auxiliary voltage 110 - 250 VDC auxiliary voltage 4 x In 50 x In 100 x In 2 x Vn 3,5 x Vn 0.5 VA for In = 5 A 0.1 VA for In = 1A 0.2 VA, Vn= 63.5 V Voltage Circuits: DC Burden: During Operation: Per Each Activated Input: 12 W 8 mA / 1 W, Vaux: 125 VDC OUTPUTS TRIPPING CONTACTS Contact Capacity: Maximum Operating Voltage: Continuous Current: Make and Carry: Breaking: 440 VAC 16 A 30 A 4000 VA ENVIRONMENTAL Temperature: Storage: -40 to +85°C Operation: -20 to +70°C Humidity: Up to 95% without condensing MECHANICAL CHARACTERISTICS • Metallic package in 19” rack and 4 units high. • Frontal HMI with LCD display and keypad. • Protection class IP52 (according to IEC 529) TYPE TESTS Isolation Test Voltage: Surge Test Voltage: Interference: Electrostatic Discharge: Radiointerference: Fast Transient: Sinusoidal Vibration: Shock: Radiofrequency Emission: 2 kV, 50/60 Hz, 1 min 5 kV peak, 0.5 J Class III according to CEI 255-22-1 Class IV according to CEI 255-22 2 Class III according to CEI 255-22-3 Class IV according to CEI 255-22-4 Class II according to CEI 255-21-1 Class I according to CEI-22521-2 according to CEI 41B (Sec) 81 and EN55022 class B Order online – save time www.GEindustrial.com/pm PACKAGING Dimensions: H 7.3" x W 19.0" x D 9.1" (185 mm x 484 mm x 231 mm) Weight: Not Packaged: 13.2 lbs (6 kg) Packaged: 15.4 lbs (7 kg) APPROVALS Compliant UL - UL listed for USA and Canada *Specifications subject to change without notice. 4 www.GEindustrial.com/Multilin