specifications:
Metrolight SmartHID™
Electronic Ballast
100/150/250-400 Watt - HPS
175/200/250/320/400/450 Watt - MH
Operating Specifications
Metrolight SmartHID™ Electronic Ballasts’ superior lumen maintenance enables the use of lower wattage lamps without sacrificing
maintained light levels. Fully programmable, the ballasts incorporate unique control abilities including SmartDIM auto profile dimming,
0-10V analog dimming and full MADLI digital control with real time feedback.
General Input Specifications
Frequency
50/60Hz
Inrush current
<25A
Harmonics (at nominal conditions)
Fully complies with EN61000-3-2
Total Harmonic Distortion
<10% at 120V, <10% at 208V, <15% at 277V.
Input current protection
Fuse (Internal)
Continuous full range dimming
 50% - 100% of full power (standard configuration)
 Minimum dimming level can be programmed anywhere from 35% - 100% depending on lamp
type, or can be programmed for reverse dimming by special configuration
 Analog dimming current draw 1.5mA per ballast. Maximum number of fixtures =1.5mA x sensor
current
Dimming options
 0-10V Analog dimming by relay, ambient sensor, daylight sensor or any other compatible
sensor
 Bi level dimming by relay or dry contact closure
 MADLI Digital dimming - with individual control and real-time feedback
 SmartDIM Auto profile dimming
Lumen maintenance
>90% over lamp life (depending on lamp type)
General Output Specifications
Open circuit voltage
300V
Ignition voltage
<4kV
Frequency
106KHz
Output regulation
+/- 1% of nominal lamp wattage with +/- 10% variance in input voltage.
Regulates output +/- 1% for changes in lamp voltage
General Specifications
Dimensions (LxWxH)
8.46" x 3.43" x 2.16" / 215 x 87 x 55mm (includes mounting feet)
Weight
3.08lb / 1.4kg
Operating temperature range
-30°C to +65°C / -22°F to 149°F
Maximum case temperature (Tc)
85°C / 185°F at test point
Operating humidity
0 to 95% RH non-condensing
Remote mounting distance
Up to 10 meters/33 feet. Longer mounting distance configurations available upon special request
General Specifications Continued
EMC
FCC Title 47 Part 18 C (non-consumer): EN55015:2006
(If the Smart Ballast is installed within a lighting fixture, an external dedicated Metrolight Line
Adapter may be required (EU only). Contact Metrolight customer support for more
information.)
EN61547; EN61000-3-2; EN61000-3-3
Regulatory Approvals
UL1029 & UL 935, Outdoor Type 1, suitable for recessed use.
EN61347-2-12
UL Listed
|
|
Nr. 40026719
Surge Protection
IEEE C62.41 Category C Low
Between phase and neutral 6KV / 3KA
Between line and ground 10KV / 1KA
Protections
Self-protection mechanisms
In the event of a short circuit, or open circuit; If the lamp fails to light; At the end of the lamp’s
life; Input current protection by internal fuse; Advanced surge protection between phase and
neutral and between line and ground; Advanced output protection against arching or shorting
to ground
Heat Management
If the Tc rises beyond 90°C / 194°F during use, the SmartHID™ ballast may switch itself off.
If the ballast’s Tc temperature reaches beyond 85°C / 185°F during use, the SmartHID™
Ballast will gradually reduce its output power to 50%, allowing the ballast to cool. When the
Tc falls below 85°C / 185°F again, the ballast will return to full output power
Dimming Specifications
Dimming delay (standard configuration)
Ballasts will ignore all dimming signals for the first 15 minutes after being switched on in order
to allow the lamp to fully warm up & stabilize as per ANSI recommendations. The dimming
delay can be disabled by special configuration
Analog dimming (standard configuration)
10V or grey/purple wires separated - 100% power;
0V or grey/purple shorted together - 50% power.
Dimming is continuous for dimming signal between >0V & <10V. (Dimming can be reversed
or maximum dimming value can be set to any level from 35-99% by special configuration
Analog dimming fade time (standard
configuration)
Fade time from 50% to 100% power - 15 seconds
Fade time from 100% to 50% power - 15 seconds
(Dimming fade time can be individually modified to anything from 15 seconds to 30 minutes
by special configuration)
Auto profile dimming (standard auto
dimming configuration)
Designed for outdoor applications such as parking lots, ballasts with auto profile dimming will
automatically dim to 50% power without any external controls or triggers, starting one hour
before the midpoint (based on the average of the previous three days’ operating hours) for a
period of 6 hours. In outdoor applications where the midpoint is ~ midnight, dimming will
automatically take place between ~ 11p.m. - 5a.m. (23:00hr - 05:00hr). (The auto profile
dimming times and percentages can be modified by special configuration to include up to 16
different steps per cycle). NOTE: There is no extra charge for this feature, but if you do not
request or order a ballast with auto profile dimming, the feature will not be turned on.
MADLI digital control
Each ballast will be assigned a random MADLI address between 1 and 1023. By using the
digital control feature, each ballast can be individually turned on or off or dimmed. Ballasts
can connect to control system by low voltage cabling, wireless or PLC. The ballasts also
provide real time feedback on operational status, power consumption, lamp voltage, ballast
temperature and other ballast and lamp parameters. A MADLI conversion box is required
when using the MADLI control feature (sold separately). Cloud capable control software and
hardware provided by Metrolight or 3rd party control providers. Consult factory for details.
Reconfiguration
Configuration capability
Via SMART TOOL control software and MADLI conversion box or just via MADLI conversion
box, ballasts can be reprogrammed/ reconfigured to:
#1. Any lamp from 175W - 450W Metal Halide or 150W - 400W HPS
#2. Enable or disable or modify the Auto profile dimming feature
#3. Change the MADLI digital ballast address
#4. Any other variable which can be reconfigured as noted in this specification sheet
Input Specifications
Input values for power, voltage and current are dependant on the lamp wattage. Other input values apply across all SmartHID™ Ballasts.
Lamp Power, Voltage and Current Specifications
450W MH lamp (U.S. only)
Input Power
478W
Input Voltage
277VAC (+10% to –15%)
Input Current
01.75A @277V
Power Factor
(at nominal conditions and full power)
>0.97
400W MH or HPS lamp
Input Power
426W
Input Voltage
200 - 277VAC (+10% to –15%)
Input Current
2.1A @ 208V, 1.98A @ 220V, 1.83A @ 240V, 1.58A @ 277V
Power Factor
(at nominal conditions and full power)
>0.96
350W MH lamp
Input Power
375W
Input Voltage
200 - 277VAC (+10% to –15%)
Input Current
1.8A @ 208V, 1.74A @ 220V, 1.61A @ 240V, 1.4A @ 277V
Power Factor
(at nominal conditions and full power)
>0.96
320W MH lamp
Input Power
344W
Input Voltage
200 - 277VAC (+10% to –15%)
Input Current
1.7A @ 208V, 1.6A @ 220V, 1.48A @ 240V, 1.2A @ 277V
Power Factor
(at nominal conditions and full power)
>0.96
250W MH or HPS lamp
Input Power
269W
Input Voltage
120 - 277VAC (+10% to –15%)
Input Current
2.3A @ 120V, 1.26A @ 220V, 1.16A @ 240V, 1.0A @ 277V
Power Factor
(at nominal conditions and full power)
>0.95
200W MH lamp
Input Power
215W
Input Voltage
120 - 277VAC (+10% to –15%)
Input Current
1.82A @ 120V, 1.0A @ 220V, 0.9A @ 240V, 0.78A @ 277V
Power Factor
(at nominal conditions and full power)
>0.95
175W MH lamp
Input Power
192W
Input Voltage
120 - 277VAC (+10% to –15%)
Input Current
1.6A @ 120V, 0.88A @ 220V, 0.8A @ 240V, 0.7A @ 277V
Power Factor
(at nominal conditions and full power)
>0.94
150W HPS lamp
Input Power
165W
Input Voltage
120 - 277VAC (+10% to –15%)
Input Current
1.4A @ 120V, 0.76A @ 220V, 0.7A @ 240V, 0.6A @ 277V
Power Factor
(at nominal conditions and full power)
>0.92
100W HPS lamp
Input Power
111W
Input Voltage
120 - 277VAC (+10% to –15%)
Input Current
0.95A @ 120V, 0.52A @ 220V, 0.47A @ 240V, 0.41A @ 277V
Power Factor
(at nominal conditions and full power)
>0.90
The SmartHID™ Electronic Ballasts 100W-450W have been designed to comply with the following ANSI standards:
Ballast
ANSI Lamp Code
100W
HPS (100V) & S54 (55V)
150W
HPS S56 (100V) & S55 (%%V)
175W
MH M152
200W
MH M136, HPS S66
250W
MH M153, M80, HPS S50
320W
MH M132, M 154
350W
MH M131, HPS S129
400W
MH M135, M155, HPSS51
450W
MH M144
Please consult factory for lamps not listed above.
Type
MH/HPS
Power
Description*
SmartHID™
MH
175W
M175MH-US-DD
8890008
8890071
200W
M200MH-US-DD
8890020
8890077
250W
M250MH-US-DD
8890002
8890070
320W
M320MH-US-DD
8890004
8890072
350W
M350MH-US-DD
8890003
8890043
400W
M400MH-US-DD
8890001
8890073
450W
M450MH-US-DD
8890021
8890078
100W 55v
M100S-US-DD-55V
8890015
N/A
150W 55v
M150S-US-DD-55V
8890040
N/A
150W 100v
M150S-US-DD-100V
8890025
N/A
250W
M250S-US-DD
8890005
N/A
400W
M400S-US-DD
8890006
N/A
HPS
Standard Configuration Standard Auto Profile
Part Number
Dimming Part Number
Please Note: These part numbers refer to standard configurations (0 -10V set to dim to 50% when V=0) and other standard parameters as
noted in these specifications. Special configurations are available upon request.
SmartHID™ Electronic Ballast 100W - 450W
Mechanical Dimensions
Cat #: 100-450WSpecSheet Rev: 08March12
SmartHID™ Electronic Ballast 100W - 450W
Wiring Diagram
ISRAEL OFFICE (Corporate Head Office)
Metrolight Ltd.,
9 Haomanut St.,
P.O. Box 8194, Netanya, 42160
T +(972) 9.863.3060
F +(972) 9.863.3050
U.S. Headquarters
Metrolight Inc.,
34197 Pacific Coast Highway,
Dana Point, CA 92629
T 949.542.7048
F 949.542.7050
U.S. Operations Center
Metrolight Inc.,
1724-B General George Patton Drive,
Brentwood, TN 37027
T 615.457.2060
F 615.457.2063
www.metrolight.com
© 2012 Metrolight Inc. All rights reserved.