specifications: Metrolight SmartHID™ Electronic Ballast 100/150/250-400 Watt - HPS 175/200/250/320/400/450 Watt - MH Operating Specifications Metrolight SmartHID™ Electronic Ballasts’ superior lumen maintenance enables the use of lower wattage lamps without sacrificing maintained light levels. Fully programmable, the ballasts incorporate unique control abilities including SmartDIM auto profile dimming, 0-10V analog dimming and full MADLI digital control with real time feedback. General Input Specifications Frequency 50/60Hz Inrush current <25A Harmonics (at nominal conditions) Fully complies with EN61000-3-2 Total Harmonic Distortion <10% at 120V, <10% at 208V, <15% at 277V. Input current protection Fuse (Internal) Continuous full range dimming 50% - 100% of full power (standard configuration) Minimum dimming level can be programmed anywhere from 35% - 100% depending on lamp type, or can be programmed for reverse dimming by special configuration Analog dimming current draw 1.5mA per ballast. Maximum number of fixtures =1.5mA x sensor current Dimming options 0-10V Analog dimming by relay, ambient sensor, daylight sensor or any other compatible sensor Bi level dimming by relay or dry contact closure MADLI Digital dimming - with individual control and real-time feedback SmartDIM Auto profile dimming Lumen maintenance >90% over lamp life (depending on lamp type) General Output Specifications Open circuit voltage 300V Ignition voltage <4kV Frequency 106KHz Output regulation +/- 1% of nominal lamp wattage with +/- 10% variance in input voltage. Regulates output +/- 1% for changes in lamp voltage General Specifications Dimensions (LxWxH) 8.46" x 3.43" x 2.16" / 215 x 87 x 55mm (includes mounting feet) Weight 3.08lb / 1.4kg Operating temperature range -30°C to +65°C / -22°F to 149°F Maximum case temperature (Tc) 85°C / 185°F at test point Operating humidity 0 to 95% RH non-condensing Remote mounting distance Up to 10 meters/33 feet. Longer mounting distance configurations available upon special request General Specifications Continued EMC FCC Title 47 Part 18 C (non-consumer): EN55015:2006 (If the Smart Ballast is installed within a lighting fixture, an external dedicated Metrolight Line Adapter may be required (EU only). Contact Metrolight customer support for more information.) EN61547; EN61000-3-2; EN61000-3-3 Regulatory Approvals UL1029 & UL 935, Outdoor Type 1, suitable for recessed use. EN61347-2-12 UL Listed | | Nr. 40026719 Surge Protection IEEE C62.41 Category C Low Between phase and neutral 6KV / 3KA Between line and ground 10KV / 1KA Protections Self-protection mechanisms In the event of a short circuit, or open circuit; If the lamp fails to light; At the end of the lamp’s life; Input current protection by internal fuse; Advanced surge protection between phase and neutral and between line and ground; Advanced output protection against arching or shorting to ground Heat Management If the Tc rises beyond 90°C / 194°F during use, the SmartHID™ ballast may switch itself off. If the ballast’s Tc temperature reaches beyond 85°C / 185°F during use, the SmartHID™ Ballast will gradually reduce its output power to 50%, allowing the ballast to cool. When the Tc falls below 85°C / 185°F again, the ballast will return to full output power Dimming Specifications Dimming delay (standard configuration) Ballasts will ignore all dimming signals for the first 15 minutes after being switched on in order to allow the lamp to fully warm up & stabilize as per ANSI recommendations. The dimming delay can be disabled by special configuration Analog dimming (standard configuration) 10V or grey/purple wires separated - 100% power; 0V or grey/purple shorted together - 50% power. Dimming is continuous for dimming signal between >0V & <10V. (Dimming can be reversed or maximum dimming value can be set to any level from 35-99% by special configuration Analog dimming fade time (standard configuration) Fade time from 50% to 100% power - 15 seconds Fade time from 100% to 50% power - 15 seconds (Dimming fade time can be individually modified to anything from 15 seconds to 30 minutes by special configuration) Auto profile dimming (standard auto dimming configuration) Designed for outdoor applications such as parking lots, ballasts with auto profile dimming will automatically dim to 50% power without any external controls or triggers, starting one hour before the midpoint (based on the average of the previous three days’ operating hours) for a period of 6 hours. In outdoor applications where the midpoint is ~ midnight, dimming will automatically take place between ~ 11p.m. - 5a.m. (23:00hr - 05:00hr). (The auto profile dimming times and percentages can be modified by special configuration to include up to 16 different steps per cycle). NOTE: There is no extra charge for this feature, but if you do not request or order a ballast with auto profile dimming, the feature will not be turned on. MADLI digital control Each ballast will be assigned a random MADLI address between 1 and 1023. By using the digital control feature, each ballast can be individually turned on or off or dimmed. Ballasts can connect to control system by low voltage cabling, wireless or PLC. The ballasts also provide real time feedback on operational status, power consumption, lamp voltage, ballast temperature and other ballast and lamp parameters. A MADLI conversion box is required when using the MADLI control feature (sold separately). Cloud capable control software and hardware provided by Metrolight or 3rd party control providers. Consult factory for details. Reconfiguration Configuration capability Via SMART TOOL control software and MADLI conversion box or just via MADLI conversion box, ballasts can be reprogrammed/ reconfigured to: #1. Any lamp from 175W - 450W Metal Halide or 150W - 400W HPS #2. Enable or disable or modify the Auto profile dimming feature #3. Change the MADLI digital ballast address #4. Any other variable which can be reconfigured as noted in this specification sheet Input Specifications Input values for power, voltage and current are dependant on the lamp wattage. Other input values apply across all SmartHID™ Ballasts. Lamp Power, Voltage and Current Specifications 450W MH lamp (U.S. only) Input Power 478W Input Voltage 277VAC (+10% to –15%) Input Current 01.75A @277V Power Factor (at nominal conditions and full power) >0.97 400W MH or HPS lamp Input Power 426W Input Voltage 200 - 277VAC (+10% to –15%) Input Current 2.1A @ 208V, 1.98A @ 220V, 1.83A @ 240V, 1.58A @ 277V Power Factor (at nominal conditions and full power) >0.96 350W MH lamp Input Power 375W Input Voltage 200 - 277VAC (+10% to –15%) Input Current 1.8A @ 208V, 1.74A @ 220V, 1.61A @ 240V, 1.4A @ 277V Power Factor (at nominal conditions and full power) >0.96 320W MH lamp Input Power 344W Input Voltage 200 - 277VAC (+10% to –15%) Input Current 1.7A @ 208V, 1.6A @ 220V, 1.48A @ 240V, 1.2A @ 277V Power Factor (at nominal conditions and full power) >0.96 250W MH or HPS lamp Input Power 269W Input Voltage 120 - 277VAC (+10% to –15%) Input Current 2.3A @ 120V, 1.26A @ 220V, 1.16A @ 240V, 1.0A @ 277V Power Factor (at nominal conditions and full power) >0.95 200W MH lamp Input Power 215W Input Voltage 120 - 277VAC (+10% to –15%) Input Current 1.82A @ 120V, 1.0A @ 220V, 0.9A @ 240V, 0.78A @ 277V Power Factor (at nominal conditions and full power) >0.95 175W MH lamp Input Power 192W Input Voltage 120 - 277VAC (+10% to –15%) Input Current 1.6A @ 120V, 0.88A @ 220V, 0.8A @ 240V, 0.7A @ 277V Power Factor (at nominal conditions and full power) >0.94 150W HPS lamp Input Power 165W Input Voltage 120 - 277VAC (+10% to –15%) Input Current 1.4A @ 120V, 0.76A @ 220V, 0.7A @ 240V, 0.6A @ 277V Power Factor (at nominal conditions and full power) >0.92 100W HPS lamp Input Power 111W Input Voltage 120 - 277VAC (+10% to –15%) Input Current 0.95A @ 120V, 0.52A @ 220V, 0.47A @ 240V, 0.41A @ 277V Power Factor (at nominal conditions and full power) >0.90 The SmartHID™ Electronic Ballasts 100W-450W have been designed to comply with the following ANSI standards: Ballast ANSI Lamp Code 100W HPS (100V) & S54 (55V) 150W HPS S56 (100V) & S55 (%%V) 175W MH M152 200W MH M136, HPS S66 250W MH M153, M80, HPS S50 320W MH M132, M 154 350W MH M131, HPS S129 400W MH M135, M155, HPSS51 450W MH M144 Please consult factory for lamps not listed above. Type MH/HPS Power Description* SmartHID™ MH 175W M175MH-US-DD 8890008 8890071 200W M200MH-US-DD 8890020 8890077 250W M250MH-US-DD 8890002 8890070 320W M320MH-US-DD 8890004 8890072 350W M350MH-US-DD 8890003 8890043 400W M400MH-US-DD 8890001 8890073 450W M450MH-US-DD 8890021 8890078 100W 55v M100S-US-DD-55V 8890015 N/A 150W 55v M150S-US-DD-55V 8890040 N/A 150W 100v M150S-US-DD-100V 8890025 N/A 250W M250S-US-DD 8890005 N/A 400W M400S-US-DD 8890006 N/A HPS Standard Configuration Standard Auto Profile Part Number Dimming Part Number Please Note: These part numbers refer to standard configurations (0 -10V set to dim to 50% when V=0) and other standard parameters as noted in these specifications. Special configurations are available upon request. SmartHID™ Electronic Ballast 100W - 450W Mechanical Dimensions Cat #: 100-450WSpecSheet Rev: 08March12 SmartHID™ Electronic Ballast 100W - 450W Wiring Diagram ISRAEL OFFICE (Corporate Head Office) Metrolight Ltd., 9 Haomanut St., P.O. Box 8194, Netanya, 42160 T +(972) 9.863.3060 F +(972) 9.863.3050 U.S. Headquarters Metrolight Inc., 34197 Pacific Coast Highway, Dana Point, CA 92629 T 949.542.7048 F 949.542.7050 U.S. Operations Center Metrolight Inc., 1724-B General George Patton Drive, Brentwood, TN 37027 T 615.457.2060 F 615.457.2063 www.metrolight.com © 2012 Metrolight Inc. All rights reserved.