Technical Data Effective August 21, 2014 0-10V Dimming 2-Lamp Ballast Catalog# Prepared by Project Date Comments Type Overview Fifth Light’s line of 0-10V Electronic Dimming Ballasts provide cost-effective, reliable dimming control for linear fluorescent lamps, down to 3% for T5/T5HO and T8 lamps. These two-lamp ballasts cover a range of lamp types and lengths installed in Eaton’s Cooper Lighting fluorescent lighting fixtures. All of the ballasts have programmed rapid start circuits, active power factor correction and lamp end-of-life protection. The ballasts are compatible with a wide variety of analog (0-10 VDC) controls and photocells. Features Ideal for use with 0-10V energy management systems, daylight harvesting and local controls Helps meet energy codes, including ASHRAE 90.1 and California Title 24, when applied properly Compatible with Energy-Saving and Low-Mercury Lamps 120-277V input for easy ordering and universal application Dimming Range: 3% for T5/T5HO and T8 Programmed Rapid Start maximizes lamp life End-of-lamp-life Shutdown circuit with Auto-reset for safe, longterm operation Active Power-factor Correction for maximum energy savings Built-in line voltage protection Starts at any dimmed level without flashing Technical Data 0-10V Dimming 2-Lamp Ballast August 2014 Specifications Dimensions (Inches/mm) Starting Light Output Starting Method: Programmed Rapid-Start Case Type a Minimum: 0V Maximum: 10 VDC Lamp Crest Factor THD Power Factor Ballast Factor Temperature 1.71 <1.7 <10% >0.98 1.0 Minimum Dimming Temperature: 50° F (10° C) Minimum Lamp Starting Temperature: 0° F (-18° C) Maximum Ambient Temperature: 104° F (40° C) Maximum Case Temperature: 167° F (75° C) Sounding Rating Class A Dimensions Case A: 1.18"H x 1.71"W x 8.58"L (30mm x43.5mm x 218mm) Case D: 1.18”H x 1.25”W x 16.88”L (30mm x 31.75mm x 428.75mm) Wiring & Wiring: Control can be wired with Class I or Class II Mounting Grounding: Ballast must be grounded in accordance with national and local electrical codes ANSI Standard C82.11, C62.41 Standards cULus Listed (Class P, Type 1 Outdoor, Type CC) Meets FCC CFR 47 Part 18 for EMI and RFI Non-consumer limits NEMA Premium Rated No PCBs 8.58 1.18 9.50 8.90 Case Type D 16.88 16.28 1.18 .26 14.58 1.25 1.00 1.18 Wiring Diagram Green (ground) Red White (neutral) Red Black (line) Yellow Ballast Yellow Purple (control +) Blue Gray (control -) Blue NNote: • Use Purple (+) and Gray (-) for connection to 0-10 VDC. • Wiring Purple and Gray together provides 3% light output. • Capping Purple and Gray separately provides 100% light output. 2 www.coopercontrol.com Technical Data 0-10V Dimming 2-Lamp Ballast August 2014 Dimming Curves Power 120% Light Output Power 120% 100% 100% 80% 80% 60% 60% 40% 40% 20% 20% 0% Light Output 0% 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 Control Voltage (VDC) Control Voltage (VDC) T5 Dimming Curve T8 Dimming Curve 7 8 9 10 Ordering Catalog # Case Type FLT-232PSUNV010-R1-C-PK A FLT-228PSUNV010-R1-C-PK D FLT-214PSUNV010-R1-C-PK D Lamp Type Lamp Watt Lamp Length (FT) Lamp Operation Voltage Input Watt Input Amps 120V Input Amps 277V Ballast Efficacy Factor 120-277V T8 32 4 57 0.489 0.210 1.54 T8 28 4 45 0.425 0.183 1.89 t8 25 3 45 0.369 0.160 1.89 T8 17 2 32 0.253 0.105 1.89 T8U 32 U 57 0.484 0.206 2.66 T8U 31 U 57 0.465 0.200 1.54 T8U 24 U 45 0.348 0.152 1.54 T8U 16 U 32 0.253 0.105 1.89 T8ES 32 (30) 4 57 0.455 0.194 2.66 T8ES 32 (25) 4 45 0.392 0.183 1.54 T5 28 4 63 0.520 0.220 1.89 T5 28 4 63 0.520 0.220 1.59/1.64 T5 21 3 47 0.400 0.170 1.59/1.64 T5ES 25 4 57 0.480 0.210 2.13/2.17 T5 14 2 32 0.270 0.120 1.75/1.80 T5 14 2 32 0.270 0.120 3.13 Series Series Series 120/277 120/277 120/277 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, GA 30269 coopercontrol.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. ACC140049 August 21, 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners. Dimming Performance 3% 3% 3%