COOPER LIGHTING - METALUX ® DESCRIPTION The accordTM redefines fluorescent lighting by improving on aesthetics, comfort and energy savings. The accordTM provides the right amount of light while eliminating surface shadows commonly found in parabolics. Therefore, accordTM increases the comfort level while providing significant energy savings. Type Catalog # Project Date Comments The accord is the ideal solution for offices, schools, hospitals, retail and other applications. TM Prepared by SPECIFICATION FEATURES A…Construction C…Ballast Access F…Shielding Shallow 3-1/4" deep housing is die formed of code gauge, prime cold rolled steel. Heavy gauge end plates are securely attached with screws for strength and rigidity and the elimination of gaps. Four auxiliary fixture end suspension points are provided. KOs for continuous row wiring. Large access plate for supply connection. Ballast can be removed from below without tools. Positively retained frosted acrylic profile lenses provide a soft but effective distribution of light. B…Electrical* E…Ref lector s Ballasts are Class “P” and are positively secured. Rotor-lock lampholders ensure positive lamp retention. UL/CUL listed. Suitable for damp locations. Reflector has high reflectance baked matte white enamel finish for luminous uniformity. D…Finish Durable cold rolled steel with multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition. G…Air Return Optional Air Return model provides air flow through air slots in the housing. 2AC 217T8 T8 LAMPS 2' x 2' Recessed Tr o f f e r S e r i e s B A D C E F 3-1/4" [83mm] 23-3/4" [603mm] LAMP CONFIGURATIONS MOUNTING DATA 11-3/4" [298mm] Access Plate 3-1/4" [83mm] 23-3/4" [603mm] ENERGY DATA Input Watts: 1-1/2" [39mm] 23-3/4" [603mm] 3-3/8" [86mm] EB Ballast & STD Lamps @ 277V 217T8 (30) Luminaire Efficacy Rating LER =FL69 LPW Catalog Number: 2AC-217 3-1/16" [78mm] 24" [610mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.47 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. ***See Drywall Frame Kit Accessory CEILING COMPATIBILITY G Grid/Lay-in Standard COOPER LIGHTING F Drywall Frame Kit Ceiling Type** Trim Type Exposed Grid Concealed T Slot Grid Flange G G or T G or T *** LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF080358 2AC PHOTOMETRICS Candela 2AC-217 Electronic Ballast (2) F17T8/TL841 lamps Angle Along II 0 737 1400 lumens 5 735 10 724 Spacing criterion: 15 707 (II) 1.2 x mounting 20 682 height, (⊥) 1.4 x 25 652 mounting height 30 616 35 574 Efficiency 84.3% 40 527 Test Report: 45 476 2AC-217.IES 50 422 55 366 LER = FL-69 LPW 60 308 Yearly Cost of 1000 65 248 188 lumens, 3000 hrs at 70 75 129 .08 KWH = $3.47 80 85 90 Across ⊥ 737 737 735 729 720 707 690 669 643 613 576 533 475 380 266 169 92 33 0 45° 737 735 729 719 703 683 658 628 594 555 511 462 408 349 274 181 99 34 0 76 32 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 100 91 83 75 69 63 58 54 50 46 44 100 87 76 66 58 52 46 42 38 35 32 100 100 84 80 70 65 59 53 50 45 44 38 38 33 34 29 31 26 28 23 25 21 98 89 80 73 67 61 56 52 48 45 42 98 85 74 65 57 51 46 41 38 34 32 98 82 68 58 50 43 38 34 30 28 25 20% 50% 50 30 10 30% 50 30 10 50 94 82 71 62 55 49 44 40 36 33 31 90 78 68 60 53 47 43 39 35 32 30 86 75 66 57 51 46 41 37 34 32 29 98 79 64 53 44 38 33 29 26 23 21 94 79 66 56 49 42 37 33 30 27 25 94 76 62 52 44 37 33 29 25 23 21 90 76 64 55 47 41 37 33 30 27 24 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 588 979 1813 2360 2360 %Lamp 21.0 35.0 64.7 84.3 84.3 %Fixture 24.9 41.5 76.8 100.0 100.0 Average 0-Deg cd/sm 1830 1735 1595 1355 998 90 74 61 51 43 37 32 28 25 23 21 Average 45-Deg cd/sm 2134 2190 2245 1901 1060 10% 30 10 86 73 62 53 46 41 36 32 29 26 24 86 72 59 50 42 37 32 28 25 23 21 0% 0 84 70 58 48 41 35 30 26 23 21 19 Average 90-Deg cd/sm 2357 2526 2444 1775 1029 ORDERING INFORMATION SAMPLE NUMBER: 2AC-217-UNV-EB82-U Rating Blank= Standard NY=New York Rated ATW-SW4= Chicago Rated Width 2=2' Width Series AC=Accord Series Number of Lamps (Not included) 2=2 Lamp Wattage (Length) 17=17W T8 (24") Shielding Blank=Frosted Acrylic SQP=Lens with Square Pattern Insert RDP=Lens with Round Pattern Insert Lamps L8835=T8 Lamp, 17W and 32W, 3500K L8841=T8 Lamp, 17W and 32W, 4100K Voltage (1) UNV=Universal Voltage 120-277 Options GL=Single Element Fuse GM=Double Element Fuse Flex=Flex installed Type A=Air (optional) (1) NOTES: Products also available in non-US voltages and frequencies for international markets. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1 or 2 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Packaging U=Unit Pack PALC=Job Pack, in carton HPT8 Ballast Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 ACCESSORIES T3A END E.Q. BRACKET PARTS BAG SHIPPING INFORMATION Catalog No. Wt. 2AC-217 28 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 6/10 ADF080358