LIGHTPLANE LIGHTBAR (2”) Wall Cantilever SPECIFICATION GUIDE Architectural Lighting Works reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.com LP2 LIGHTBAR Wall Cantilever Page 1 of 3 TYPE: Specification and Ordering Information: 1. Style: LP2LBWCI - Indirect Wall Cantilever (LP2LBWCI) LP2LBWCD - Direct Wall Cantilever (LP2LBWCD) 2. Overall Run Length: Individual (2’,3’,4’,5’,6’,7’,8’) 3. Linear Lamping *HP900- 900 Lm/ft High Performance LED 7W/LF (HP900- Old HP7) 2700K 3000K 3500K 4000K 5000K HP1200 - 1200 Lm/ft High Performance LED 9W/LF (HP1200 - Old HP10) 2700K 3000K 3500K 4000K 5000K HP1500 - 1500 Lm/ft High Performance LED 14.5W/LF (HP1500 - Old HP14) 2700K 3000K 3500K 4000K 5000K HPTW - High Performance Tunable White 2700K to 5700K LED (HPTW) 3" **1300 (Lm/ft & 8W/FT) **2200 (Lm/ft & 16.5W/LF) Custom (specify Lumens per foot requirements: min. **700 Lm/ft & 4.4W/LF, max. **3300 Lm/ft & 24.5W/LF) CV450- Decorative, 440 Lm/ft, Constant Voltage LED 6.5W/LF (CV450) Style: LP2LBWCI 3000K 4000K with WD (lens) RGB - LED Color Changing 5W/LF -Consult Factory for Control Interface Options (RGB) T5 - Fluorescent - Standard Output T5 (T5) Δ 1S (1-lamp Staggered) 1R (1-lamp Regular) 1 T5HO - Fluorescent - High Output T5 (T5HO) 2 2" Δ 1S (1-lamp Staggered) 1R (1-lamp Regular) 1 2 4" ***LX - Fluorescent T5 Seamlessline - Standard Output (LX) 1R (1-lamp Regular) - Only available option Style: LP2LBWCD ***LXHO - Fluorescent T5 Seamlessline - High Output (LXHO) 1R (1-lamp Regular) - Only available option *HP900 only, depending on run length, CV or CC LED boards will be provided to reduce driver numbers. CV and CC HP boards share the same LED chips and lumen value. **Raw lumens and system watts information when both warm white and cool white LEDs are at 100% DALI or DMX drivers are recommended to halve driver numbers. ** *See Option 1A Δ For Staggered lamping it is recommended to use the EXT lens for maximum diffusion properties - Staggering T5 in a 2” channel will still show some socket image with EXT lens. Staggering with High output T5 is not recommended. Raw lumens and system watts (with driver loss included for all other LEDs) LED board length increment availability: HP series - 11.2”, HP900 CV series - 2.25”, CV series - 2” 3" Style: LP2LBWCD with WD (lens) 1 2 2" Style: LP2LBWCD with RO (reflector only) 4. Linear Driver/Ballast Specification: *LED - LED Power Supply, non-dim (LED) *LED-DIM - LED Power Supply with 0-10V dimming (LED-DIM) 10% Standard Option 1% Premium Option 0% Premium Option *LED-DALI - LED Power Supply with DALI dimming 0%-100% (LED-DALI) *LED-DMX - LED Power Supply with DMX dimming 0%-100% (LED-DMX) *RGB-DMX- RGB with DMX Interface module 0%-100% DMX controller not included (RGB-DMX) *HILUME-A2- Lutron Hi-lume® A LTE Series LED line voltage 2-wire control (120v only) 1%-100% (HILUME-A2) *HILUME-A3- Lutron Hi-lume® A L3D Series LED EcoSystem® or 3-wire control 1%-100% (HILUME-A3) STD - Standard Electronic, non-dim <10%THD (STD) MK7 - Advance Mark 7® Dimming 0-10V (MK7) MK10 - Advance Mark 10® Dimming (MK10) HILUME3D - Lutron Hilume 3-D® (HILUME3D) Design Notes: HSERIES- Lutron H-SERIES® Dimming (HSERIES) 1) Allow 6” for each Downlight ECOSYS- Lutron ECOSYSTEM® Dimming (ECOSYS) 2) Add 6” to overall dimension when using downlights BALSTAR - Ballastar® Light level switching (BALSTAR) USD - Superdim® Dimming (USD) For example: QUICK - Osram Quicktronic® Dimming (QUICK) A 4ft LP2LBWCI designed with (2) MR16 lamps and * OPTION FOR LINEAR LED ONLY fluorescent indirect will use a 3ft fluorescent lamp Please consult ballast manufacturer for lamp/ballast compatibility. allowing for 6”of downlight space on each side 5. Downlight Option (leave blank if none): MR16 - 50 W MR16 Halogen (MR16) LED MR16 - Retrofit LED MR16 GU5.3 Base, Transformer: 120 volt to 12 volt only for dimming, lamp supplied by others (LEDMR16) GX 1020- 20W CMH-MR16 GX10 Base(GX1020) GX1039-39W CMH-MR16 GX10 Base(GX1039) Continued on Next Page... Architectural Lighting Works reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.com LP2 LIGHTBAR Wall Cantilever Page 2 of 3 TYPE: 6. Downlight Quantity: Enter total quantity downlights per run length (Leave blank if none) Outer Dimensions of Each Downlight is 6” Lamp Configuration Chart: Individual and Continuous 7. Accessory options: Downlight: HEX - Hexcell Louvers (HEX) SNT - Snoot (SNT) SOL - Solite Lens (SOL) LSS - Linear Spread Lens (LSS) 8. Circuit: 9. Voltage: Regular 2’ 14 or 24w T5 1 21 or 39w T5 28 or 54w T5 35 or 80w T5 3’ 4’ 5’ 6’ 1 2 1 1 1CKT - One Circuit (1CKT) 2CKT - Two Circuits (2CKT) *EMC - Emergency Circuit (EMC) *EMBP - Emergency Battery Pack (Fluorescent only) (EMBP) *REMBP - Remote Emergency Battery Pack (LED or job specific) (REMBP) *Consult factory for available options *120 - 120 volt (120) 277 - 277 volt (not available for dimming MR16)(277) UNV - Universal voltage (UNV) 347 - 347 volt (not available in dimming) (347) *For LED MR16 Downlight dimming, consult LED Retrofit Lamp manufacturer for dimmer compatibility * AL (Natural “Ultimatte” aluminum) BK (Black powdercoat) WH (White powdercoat) RAL (Specify RAL # of powdercoat of your choice) * AL is standard on all Lightplane 2 Lightbar product ***1A - Option: Seamlessline Lamp (SL) End to End Lamp Mounting ***Channel dimensions identical to standard T5 lamping. Luminous ends eliminate the need for staggered lamping. Consult factory for additional details. ACROSS 45 ALONG Spacing Criterion 1.2 1.3 250 Efficiency 61.1 % 375 Catalog # LP2LBSI-4-FSO-STD-120WD Architectural Lighting Works reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.com 1 1 12. Additional Options: *OS - Occupancy Sensor (OS) *PH - Photocell - Consult Factory (PH) SB - Seismic Bracing- Consult Factory (SB) * Consult factory for options. Size limitations exist 125 8’ 9’ 10’ 11’ 12’ 1 10. Accessory Options (Indirect/Direct): *WD - Lens (WD) **EXT - Extra Diffuse Lens (EXT) *Not recommended with Staggered T5 **Recommended for maximum diffusion and least lamp image. Socket shadow is still visible with EXT when staggering T5HO. LV - Louver (LV) RO - Open Top, Reflector Only, not available with LED lamping (RO) DG - Flush guard lens - Indirect only (DG) 11. Finish: 7’ 3 2 1 2 2 3 LP2 LIGHTBAR Wall Wa ll Cantilever Page 3 of 3 TYPE: Standard: Pendant Wire Mounting with adjustable aircraft cable suspension for Tie-back *4-1/2” dia. canopy to cover 4-O Octagon Junction box Bullet Aircraft cable suspension. *Adjustable GripLock cable suspension Option: Seismic Bracing Aircraft cable can mount on side of channel to seismic anchoring. Colors and Finishes: RAL STANDARD: “Ultimatte” Natural aluminum : A two step, clear anodizing process that gives and durable surface. OPTION: Black - BK powdercoat OPTION: White - WH powdercoat OPTION: RAL - powdercoat the RAL color of your choice. Specify RAL code. Lamp Shielding Accessories: Hexcell Louver (HEX) Linear Spread Lens (LSS) Solite Lens (SOL) Snoot (SNT) Note: Accessories are not universal. Please consult specification sheets online for lamp compatibility. Design Specifications Construction Extruded architectural grade T6061 aluminum. Minimum wall thickness is .080” 100% recyclable. Reflectors are formed from .040 aluminum and finished in Titanium white powdercoat. Lenses are made from twin layered extruded high-impact acrylic. WD is a full frosted/transparent combination. EXT is a half frosted/white combination. Single piece construction aluminum louver with clear matte anodized finish. Electrical Details All ballasts are electronic <10% THD Class P electronic ballasts - Programmed start Standard and dimming ballasts are integral to channel (unless otherwise noted). Low voltage transformers are individual 75W units (277V/12V non-dim or 120/12V) All LED drivers are integral electronic Class 2 unless otherwise noted. LED light engine is LM-80 compliant with 80 CRI minimum. Multiple interface options available including dimming, motion sensing, daylight harvesting and DALI. ETL listed Damp with Lens Emergency Fixtures can be wired for emergency circuit or emergency battery backup. Emergency one-lamp ballasts provide 90 minutes of illumination. T5/T5HO = Initial output of 1300 Lumens Finish All fixtures are standard in Ultimatte aluminum finish (AL) A deep etch and two-step clear anodizing process that gives a smooth, clean and durable surface. Powder Coat options are available. Consult factory. Architectural Lighting Works reserves the right to make changes to fixture design, finish and engineering at any time. www.archltgworks.com