InPOWER the systems people www.offroadengineering.com (949) 581 2991 VEHICLE CONTROL MODULES Provide Easy Solutions for Complex Circuit Applications Put InPower in your Tool Box! Latching Relay Low Voltage Disconnect Alternating Lamp Flasher On-Delay Time Delay Relay Off-Delay Time Delay Relay One-Shot Time Delay Relay SOLUTIONS you can count on www.offroadengineering.com InPOWER the systems people www.offroadengineering.com (949) 581 2991 VEHICLE CONTROL MODULES InPower’s Vehicle Control Module (VCM) product line is a rapidly evolving set of “tools” used to provide solutions for vehicle electrical system applications. The VCM’s employ a micro processor controller coupled with a solid state 12 volt 15 amp power switch to provide a completely solid state “smart” relay. By applying different software programs we can provide a wide range of product functions. After launching our first group of VCM products our customers have responded with additional product applications, thereby expanding the product line. The following describes our current VCM’s. Please visit our website for more details and the latest product additions. Feel free to contact us to discuss your application requirements. VCM-01 Latching Relay This latching relay’s output will toggle to the opposite state each time the input is activated. One of it’s uses is to turn on/off compartment lights from one or more momentary control switches. VCM-03 Series On-Delay Timer This time delay relay’s output will activate after a time delay when it’s input is set, and will remain on until it’s input is turned off. It can be used where one control action needs to take place at a fixed time after another control action. This provides a delayed on, instant off function. Available with fixed or adjustable time values. VCM-04 Series Off-Delay Timer This time delay relay’s output will be activated immediately when it’s input is set. When it’s input is removed the timer will start, and it’s output will shut off when the timer expires. This provides an instant on, delayed off function. Fixed and adjustable time values are available. VCM-05 Series One-Shot Timer If not already in a timed-out sequence, this time delay relay will produce an output pulse of a timed duration when it’s input is set. This provides a fixed timed output regardless of it’s input being a short duration or long duration. Fixed and adjustable time values are available. VCM-05 One-Shot Timer Time Adjustment Microprocessor Controller VCM-08 Alternating Flasher Electronic Power Switch Ground +12 Volts Output Input B Input A LOAD Ground Switch Ground Switch +12 Volts When a ground is applied to it’s input, this flashing relay will alternately operate it’s dual 15 amp outputs at a rate of 75 cycles per minute at 50% duty cycle. It can be used to operate low current LED lights or high current halogen and incandescent lights. Use one or both outputs depending upon your design requirements. VCM Low Voltage Disconnect These low voltage disconnect (LVD) modules measure the battery voltage at their input and control their outputs based on the voltage being above or below a fixed reference point. They are used to remove power from battery loads before the battery charge drops below it’s ability to start the engine. For more information visit www.offroadengineering.com · 949.581.2991 SB-45A 032608 InPOWER the systems people Contents Document Vehicle Control Module Product Specifications: VCM-01Latching Relay, 12 Volt VCM-03 Time Delay Relay, On-Delay VCM-04 Time Delay Relay, Off-Delay VCM-05 Time Delay Relay, One-Shot VCM-06 Low Voltage Disconnect with timer VCM-08 Alternating Flasher CA-VCM1 Socket harness Assembly PDS-58A PDS-59B PDS-60D PDS-61C PDS-72A PDS-62B PDS-73A Vehicle Control Module Application Bulletins: Remote Controlled Engine Idle Circuit Remote Controlled Compartment Light Circuit Delayed 12 Volt Circuit Operation Bus Egress Light Timer Circuit Bus Mirror Heater Timer Circuit Bus Stop Request Circuit Bus Alternating Warning Light Circuit AB-10A AB-11A AB-12A AB-13B AB-14C AB-15A AB-16A Vehicle Control Module Sales Bulletins: School Bus Egress Lamp Timer Automatic Mirror heater Shut-off Timer SB-38A SB-35A Revised April 16, 2008 InPOWER VCM Series the systems people Vehicle Control Modules VCM-01 Latching Solid State Relay, Alternating InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-01 is a completely solid state alternating latching relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the output to latch (or unlatch). Key Features • 100% Solid State Construction The output will toggle to the opposite state when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B when Input A is open. Another toggle will not be recognized until both inputs are open. To toggle the module’s output, a control input signal must be applied for at least 250 milliseconds with its counterpart input open. All control inputs must be removed for at least one second before the module will recognize another toggle control input. When +12 volts is first applied to its power terminal (86) the module will initialize in the output off state. The output is rated at +12 volts @ 15 amps and provides over current and short circuit shut down protection. • Standard Automotive Relay Pin Format • 12 Volt 15 Amp Solid State Output • Compact Size with Panel-Mount Bracket • Dual Inputs - Ground and +12 Volt • Durable Metal Case Ordering Guide Model Description VCM-01 Solid state alternating latching relay with +12 volt @ 15 amp output and two inputs Wiring Diagram InPower VCM-01 87a Input A Terminal Layout 86 30 +12 Volts Microprocessor Controller 87 Input B Ground 85 Vehicle Ground (Battery Negative) 86 +12 Volt 15 Amp Fused Power Source Control 85 Switch Ground 87 87a Switch +12 Volts Electronic Power Switch 30 Output +12 Volts @ 15 Amps 12 Volt Load Ground PATENT PENDING Product Data Sheet PDS-58A VCM-01 Latching Relay, Alternating Specifications Timing Diagram Power Input (86): Ground (85): +8 to 16 Vdc @ 15 amps Connection to vehicle ground (Battery Negative) External contact closure to ground External contact closure to +12 volts +12 volts @ 15 amps in latched state Input A (87): Input B (87a): Module Output (30): Mechanical Weight: Operating Temperature: Dimensions: Input A Output 0V +12V 0V Input B 0.10 lbs. -40° C to +85° C 1.75” H x 2.30” W x 1.25” D +12V Output +12V 0V +12V 0V Installation 1. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). 2. The module should be installed on the inside of the vehicle in a dry and protected environment. 3. For optimum power output performance the product should be mounted to a metal surface. 4. Do not connect loads to the output that will exceed the output current rating of the module. 5. The 12 volt power input (86) must be from a properly fused +12 volt power source. 6. Wiring must be of the proper gage and type to handle the intended load currents. 7. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. 8. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing 0.35 1.25 0.35 1.80 2.30 87 86 87a 85 1.75 30 0.063 All dimensions in inches. Not to scale. InPOWER LLC Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-58A 050207 Copyright2007 2002InPOWER InPOWERLLC LLC ©©Copyright Specificationssubject subjecttotochange changewithout withoutnotice. notice. Specifications www.offroadengineering.com (949) 581 2991 InPOWER VCM Series the systems people Vehicle Control Modules VCM-03.X Time Delay Solid State Relay, On-Delay InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-03.X is a completely solid state adjustable on-delay timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. Key Features When an input is applied and maintained, the timer will start. When the timer expires the output will be activated. The output will remain activated until both inputs are open (cleared). The time period is adjustable with a single turn potentiometer. Time ranges include: 010 seconds, 0-60 seconds, 0-3 minutes, 0-10 minutes and 0-60 minutes. • 100% Solid State Construction • Standard Automotive Relay Pin Format • 12 Volt 15 Amp Solid State Output The timer will start when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. The input must be maintained to operate the timer. If removed during the timer operation (before the timer expires) the operation will reset. With the input applied, when the timer expires the output will be activated, and will remain activated until the inputs are removed. The output is rated at +12 volts @ 15 amps and provides over current and short circuit shut down protection. • Compact Size with Panel-Mount Bracket • Dual Inputs - Ground and +12 Volt • Durable Metal Case Ordering Guide Model VCM-03.10SA VCM-03.60SA VCM-03.03MA VCM-03.10MA VCM-03.60MA Time Range 0 - 10 Sec. 0 - 60 Sec. 0 - 3 Min. 0 - 10 Min. 0 - 60 Min. Description Solid state on-delay timer relay, +12 volt @ 15 amp output and two inputs Solid state on-delay timer relay, +12 volt @ 15 amp output and two inputs Solid state on-delay timer relay, +12 volt @ 15 amp output and two inputs Solid state on-delay timer relay, +12 volt @ 15 amp output and two inputs Solid state on-delay timer relay, +12 volt @ 15 amp output and two inputs Wiring Diagram InPower VCM-03.X Time Adjustment Terminal Layout Microprocessor Controller 86 30 87 Ground Vehicle Ground (Battery Negative) 86 +12 Volt 15 Amp Fused Power Source Control 85 +12 Volts Switch 85 +12 Volts Electronic Power Switch 30 PATENT PENDING Input B Switch Ground 87 87a 87a Input A Output +12 Volts @ 15 Amps LOAD Ground Product Data Sheet PDS-59B VCM-03.X Time Delay Solid State Relay, On-Delay Timing Diagram Specifications Power Input (86): Ground (85): Input A (87a): Input B (87): Module Output (30): +8 to 16 Vdc @ 15 amps Connection to vehicle ground (Battery Negative) External contact closure to +12 volts External contact closure to ground +12 volts @ 15 amps Mechanical Weight: Operating Temperature: Dimensions: 0.10 lbs. -40° C to +85° C 1.75” H x 2.30” W x 1.25” D Input A Output +12 V 0V +12 V Time 0V +12 V Input B Output 0V +12 V Time 0V Installation 1. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). 2. The module should be installed on the inside of the vehicle in a dry and protected environment. 3. For optimum power output performance the product should be mounted to a metal surface. 4. Do not connect loads to the output that will exceed the output current rating of the module. 5. The 12 volt power input (86) must be from a properly fused +12 volt power source. 6. Wiring must be of the proper gage and type to handle the intended load currents. 7. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. 8. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing 0.35 1.25 0.35 1.80 2.30 87 86 87a 85 1.75 30 0.063 All dimensions in inches. Not to scale. InPOWER LLC Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-59B 030608 Copyright2008 2002InPOWER InPOWERLLC LLC ©©Copyright Specificationssubject subjecttotochange changewithout withoutnotice. notice. Specifications www.offroadengineering.com (949) 581 2991 InPOWER VCM Series the systems people Vehicle Control Modules VCM-04.X Time Delay Solid State Relay, Off-Delay InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-04.X is a completely solid state adjustable offdelay timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. Key Features When an input is applied the output will immediately be activated. When the input is removed, the timer will start and the output will remain activated. When the timer expires the output will deactivate. The time period is adjustable with a single turn potentiometer. Time ranges include: 0-10 seconds, 0-60 seconds, 0-3 minutes, 0-10 minutes, 0-60 minutes, and fixed 5 seconds. • 100% Solid State Construction • Standard Automotive Relay Pin Format • 12 Volt 15 Amp Solid State Output The output will be activated when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. When the applied input has cleared, and its counterpart input is also clear, the timer will start. When the timer has expired the output will be deactivated and the operation is complete. The output is rated at +12 volts @ 15 amps and provides over current and short circuit shut down protection. • Compact Size with Panel-Mount Bracket • Dual Inputs - Ground and +12 Volt • Durable Metal Case Ordering Guide Model VCM-04.10SA VCM-04.60SA VCM-04.03MA VCM-04.10MA VCM-04.60MA VCM-04.05SF VCM-04.05MF Time Range 0 - 10 Sec. 0 - 60 Sec. 0 - 3 Min. 0 - 10 Min. 0 - 60 Min. 5 Sec. Fixed 5 Min. Fixed Description Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Wiring Diagram InPower VCM-04.X Time Adjustment Terminal Layout 86 30 87 Input B Switch Ground Ground Vehicle Ground (Battery Negative) 86 +12 Volt 15 Amp Fused Power Source Control 85 Switch 85 +12 Volts Electronic Power Switch 30 PATENT PENDING Input A +12 Volts Microprocessor Controller 87 87a 87a Output +12 Volts @ 15 Amps LOAD Ground Product Data Sheet PDS-60D VCM-04.X Time Delay Solid State Relay, Off-Delay Timing Diagram Specifications Power Input (86): Ground (85): Input A (87a): Input B (87): Module Output (30): +8 to 16 Vdc @ 15 amps Connection to vehicle ground (Battery Negative) External contact closure to +12 volts External contact closure to ground +12 volts @ 15 amps Mechanical Weight: Operating Temperature: Dimensions: 0.10 lbs. -40° C to +85° C 1.75” H x 2.30” W x 1.25” D +12 V Input A 0V Time Output +12 V 0V +12 V Input B 0V Time Output +12 V 0V Installation 1. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). 2. The module should be installed on the inside of the vehicle in a dry and protected environment. 3. For optimum power output performance the product should be mounted to a metal surface. 4. Do not connect loads to the output that will exceed the output current rating of the module. 5. The 12 volt power input (86) must be from a properly fused +12 volt power source. 6. Wiring must be of the proper gage and type to handle the intended load currents. 7. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. 8. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing 0.35 1.25 0.35 1.80 2.30 87 86 87a 85 1.75 30 0.063 All dimensions in inches. Not to scale. InPOWER LLC Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-60D 030608 Copyright2008 2002InPOWER InPOWERLLC LLC ©©Copyright Specificationssubject subjecttotochange changewithout withoutnotice. notice. Specifications www.offroadengineering.com (949) 581 2991 InPOWER VCM Series the systems people Vehicle Control Modules VCM-05.X Time Delay Solid State Relay, One-Shot InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-05.X is a completely solid state adjustable oneshot timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. Key Features If the module is not already in a time-out sequence, its output will be activated for the adjustable time period when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. In other words, the module will not start another time sequence until both inputs are removed and the module is not in a time-out sequence. An input control signal must be applied for a minimum of 250 milliseconds, with its counterpart input open, to initiate a time-out sequence. Also, both control inputs must be removed for at least one second before another time-out sequence can be initiated. The time period is adjustable with a single turn potentiometer. Time ranges available include: 0-10 seconds, 0-60 seconds, 0-3 minutes, and 0-10 minutes, 0-60 minutes, and fixed 120 seconds. The output is rated at +12 volts @ 15 amps and provides over current and short circuit shut down protection. • 100% Solid State Construction • Standard Automotive Relay Pin Format • 12 Volt 15 Amp Solid State Output • Compact Size with Panel-Mount Bracket • Dual Inputs - Ground and +12 Volt • Durable Metal Case Ordering Guide Model VCM-05.10SA VCM-05.60SA VCM-05.03MA VCM-05.10MA VCM-05.60MA VCM-05.02MF Time Range 0 - 10 Sec. 0 - 60 Sec. 0 - 3 Min. 0 - 10 Min. 0 - 60 Min. Fixed 120 Sec. Description Solid state one-shot time delay relay with +12 volt @ 15 amp output and two inputs Solid state one-shot time delay relay with +12 volt @ 15 amp output and two inputs Solid state one-shot time delay relay with +12 volt @ 15 amp output and two inputs Solid state one-shot time delay relay with +12 volt @ 15 amp output and two inputs Solid state one-shot time delay relay with +12 volt @ 15 amp output and two inputs Solid state one-shot time delay relay with +12 volt @ 15 amp output and two inputs Wiring Diagram InPower VCM-05.X Time Adjustment Terminal Layout 86 30 Input A 87 Input B Ground Ground Vehicle Ground (Battery Negative) +12 Volts 86 +12 Volt 15 Amp Fused Power Source Electronic Power Switch 30 Output +12 Volts @ 15 Amps PATENT PENDING Switch 85 Control 85 Switch +12 Volts Microprocessor Controller 87 87a 87a LOAD Ground Product Data Sheet PDS-61C VCM-05.X Time Delay Solid State Relay, One-Shot Specifications Timing Diagram Power Input (86): Ground (85): Input A (87a): Input B (87): Module Output (30): +8 to 16 Vdc @ 15 amps Connection to vehicle ground (Battery Negative) External contact closure to +12 volts External contact closure to ground +12 volts @ 15 amps Mechanical Weight: Operating Temperature: Dimensions: 0.10 lbs. -40° C to +85° C 1.75” H x 2.30” W x 1.25” D Input A Input B +12 V 0V +12 V 0V Time +12 V Output Input A Input B 0V +12 V 0V +12 V 0V Time Output +12 V 0V Installation 1. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). 2. The module should be installed on the inside of the vehicle in a dry and protected environment. 3. For optimum power output performance the product should be mounted to a metal surface. 4. Do not connect loads to the output that will exceed the output current rating of the module. 5. The 12 volt power input (86) must be from a properly fused +12 volt power source. 6. Wiring must be of the proper gage and type to handle the intended load currents. 7. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. 8. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing 0.35 1.25 0.35 1.80 2.30 87 86 87a 85 1.75 30 0.063 All dimensions in inches. Not to scale. InPOWER LLC Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-61C 030608 Copyright2008 2002InPOWER InPOWERLLC LLC ©©Copyright Specificationssubject subjecttotochange changewithout withoutnotice. notice. Specifications www.offroadengineering.com (949) 581 2991 PRELIMINARY InPOWER VCM Series the systems people Vehicle Control Modules VCM-06 Low Voltage Power Disconnect With Adjustable Timer InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description Key Features • Voltage >13.25 - Output On • Voltage <12.8 - Output Off After Adjustable Time Delay • Voltage <11.8 - Output Instant Off • 12 Volt 15 Amp Solid State Output With Over Current Shutdown • Standard Automotive Relay Pin Format • Compact Size With Panel-Mount Bracket • 100% Solid State Construction • Durable Metal Case The InPower VCM-06 is a completely solid state 15 amp automatic power disconnect switch for 12 volt loads. The module contains a microprocessor controller and a solid state 15 amp power switch for powering the output loads. The module will continuously monitor the voltage level of the 12 volt power input terminal. If the voltage is above 13.25 volts the power switch will turn on to supply up to 15 amps on the output terminal to power the loads. If the voltage on the input drops below 12.8 volts a timer is started (adjustable 0 to 2 hours). If the voltage remains below 12.8 volts until the timer expires the power switch will turn off, disconnecting the power to the loads. If the voltage drops below 11.8 volts with the timer running the power switch is shut off immediately. Any time the input voltage increases to above 13.25 volts the power switch will turn on to supply power to the loads and the timer will be reset. The timer is adjustable via a single turn potentiometer (adjustable from zero to two hours). The output is rated at +12 volts @ 15 amps and provides over current and short circuit fault shut down protection. If a fault condition is detected, the power switch will turn off and remain latched off until the input voltage is cycled to below 13.0 volts. The power switch will turn on when the voltage increases to above 13.25 volts. Wiring Diagram InPower VCM-06 Time Adjustment Microprocessor Controller Ground 85 Vehicle Ground (Battery Negative) 87 * 87a Terminal Layout * Control +12 Volts 86 85 30 Optional Disconnect Switch Power In 86 +12 Volt 15 Amp Fused Power Source Electronic Power Switch Power Out 30 +12 Volts @ 15 Amps 12 Volt Loads Ground * Not used PATENT PENDING Product Data Sheet PDS-72A VCM-06 Low Voltage Timed Power Disconnect Specifications Power Operating Range (86): Ground (85): Module Output (30): Mechanical Weight: Operating Temperature: Dimensions: +8 to 16 Vdc @ 15 amps Connection to vehicle Ground (Battery Negative) +12 volts @ 15 amps, over current and short circuit shutdown fault protection Output Disconnect Operation: Input voltage >13.25 - Output on Input voltage <12.8 - Output off after timer expires (0 to 2 hour adjustable) Input Voltage <11.8 - Output Instant Off 0.10 lbs. -40° C to +85° C 1.75” H x 2.30” W x 1.25” Installation 1. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). 2. The module should be installed on the inside of the vehicle in a dry and protected environment. 3. For optimum power output performance the product should be mounted to a metal surface. 4. Do not connect loads to the output that will exceed the output current rating of the module. 5. The 12 volt power input (86) must be from a properly fused +12 volt power source. 6. Wiring must be of the proper gage and type to handle the intended load currents. 7. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. 8. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing 0.35 1.25 0.35 1.80 2.30 86 85 1.75 30 0.063 All dimensions in inches. Not to scale. InPOWER LLC Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-72A 010808 Copyright2008 2002InPOWER InPOWERLLC LLC ©©Copyright Specificationssubject subjecttotochange changewithout withoutnotice. notice. Specifications www.offroadengineering.com (949) 581 2991 InPOWER VCM Series the systems people Vehicle Control Modules VCM-08 Dual 15 Amp Alernating Lamp Flasher InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-08 warning lamp flasher represents a breakthrough in solid state flasher technology. The use of advanced SMT and packaging technology results in a very compact, high performance flasher with exceptional reliability and low cost. Key Features • 100% Solid State Construction The VCS-08 flasher is a completely solid state dual output alternating warning lamp flasher. Its outputs are rated at +12 volts @ 15 amps each, and are designed to operate high in-rush current halogen and incandescent lamps, as well as LED lights. • Operates Halogen and LED Lamps • Standard Automotive Relay Pin Format When a ground is applied to the input, the outputs will alternately flash at a rate of 75 cycles per minute at a 50% duty cycle. The solid state outputs are a unique design that will automatically shut off if an over current or short circuit fault occurs. If a fault shut down occurs on one output the other output will remain operational. • Dual 12 Volt 15 Amp Solid State Outputs • Compact Size with Panel-Mount Bracket • High Technology Power Switching Circuit • Durable Metal Case Ordering Guide Model Description VCM-08 Solid state alternating lamp flasher with single input and two +12 volt @ 15 amp outputs. Wiring Diagram InPower VCM-08 Microprocessor Controller Terminal Layout 87 86 Control +12 Volts 87 Ground 30 +12 Volt 15 Amp Fused Power Source Electronic Power Switches 85 85 Switch Input Lights Output A +12 volts @ 15 amps 30 86 Lights Output B Ground +12 volts @ 15 amps Ground PATENT PENDING Product Data Sheet PDS-62B VCM-08 Solid State Dual 15 Amp Alternating Flasher Specifications Timing Diagram Power Input (30): Control Input (87): Output A (85): Output B (86): Flash Rate: +8 to 16 Vdc @ 15 amps External contact closure to ground +12 volts @ 15 amps +12 volts @ 15 amps 75 per minute Mechanical Weight: Operating Temperature: 0.10 lbs. -40° C to +85° C Input +12 V 0V Output A +12 V 0V Output B +12 V 0V Installation 1. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). 2. The module should be installed on the inside of the vehicle in a dry and protected environment. 3. For optimum power output performance the product should be mounted to a metal surface. 4. Do not connect loads to the output that will exceed the output current rating of the module. 5. The 12 volt power input (30) must be from a properly fused +12 volt power source. 6. Wiring must be of the proper gage and type to handle the intended load currents. 7. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. 8. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing 0.35 1.25 0.35 1.80 2.30 87 86 85 1.75 30 0.063 All dimensions in inches. Not to scale. InPOWER LLC Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-62B 070507 Copyright2007 2002InPOWER InPOWERLLC LLC ©©Copyright Specificationssubject subjecttotochange changewithout withoutnotice. notice. Specifications www.offroadengineering.com (949) 581 2991 InPOWER VCM Series the systems people Vehicle Control Modules VCM-CA1 Socket Harness Assembly InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-CA1 Socket Harness Assembly consists of a 5-pin socket with attached color coded wires. The socket is a universal automotive relay configuration with five sets of contacts. This socket fits the InPower Vehicle Control Module (VCM Series) products. Each wire is color coded, stripped and tinned. VCM Module Stripped & Tinned Ends Color Coded Wires 5-Pin Socket 10” View looking into VCM Module Wire Colors Terminal Layout 87 86 87a 30 85 Pin 87 87a 30 85 86 InPOWER the systems people PDS-73A 100907 Copyright © 2007 InPower LLC Specifications subject to change without notice. Wire Color Yellow Red Blue Black White Wire Size 14 AWG 14 AWG 14 AWG 16 AWG 16 AWG Product Data Sheet 3555 Africa Road • Galena, Ohio 43021 Tel: 740-548-0965 • Fax: 740-548-2302 www.InPowerDirect.com PDS-73A InPOWER VCM Series the systems people Application Bulletin Remote Controlled Engine Fast Idle Circuit Latching circuit toggles the engine fast idle controller on/off from a remote switch. Product Information InPower Model: VCM-01 Alternating Latching Solid State Relay, 12 volt Description: The VCM-01 module contains two inputs, one actuated by a transition to +12 volts and one actuated by a transition to ground. The module’s output will toggle to the opposite state when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. The module’s output is +12 volts @ 15 amps when in the latched state. Upon power up the output is in the unlatched state. Documentation: Product Data Sheet PDS-58 Operation Operating the remote switch the first time will cause the VCM-01 module to set its output to the latched state (output terminal 30 at +12 volts). When set, the output will activate the engine fast idle circuit. Operating the remote switch a second time will reset the VCM-01 output to the unlatched state (no power on terminal 30). When powering up (+12 volts in terminal 86) the VCM-01 module will be in the un-latched state (no power on terminal 30). Application Wiring Diagram 1 - (Remote switch connected to ground) Remote Switch (Momentary) Input B Ground 87 86 +12 Volts 87a InPower VCM-01 +12 Volt Alternating Latching Solid State Relay 85 30 Output To engine fast idle circuit (Engine Control Module or InPower ETM Series Fast Idle Electronic Throttle) Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 www.InPowerDirect.com © Copyright 2007 949.581.2991 InPower LLC Ground +12 volts @ 15 amps when in latched state Page 1 of 2 Application Bulletin AB-10A Version: A Date: June 18, 2007 InPOWER VCM Series the systems people Application Bulletin Wiring Diagram 2 (Remote switch connected to +12 volts) Remote Switch (Momentary) Input A +12 Volts 87 86 +12 Volts 87a InPower VCM-01 +12 Volt Alternating Latching Solid State Relay 85 30 Output To engine fast idle circuit (Engine Control Module or InPower ETM Series Fast Idle Electronic Throttle) Ground +12 volts @ 15 amps when in latched state Wiring Diagram 3 (Two remote switches, connected to +12 volts and to ground) Remote Switch (Momentary) Input A +12 Volts Input B Remote Switch (Momentary) 87 86 +12 Volts Ground 87a InPower VCM-01 +12 Volt Alternating Latching Solid State Relay 85 30 Output To engine fast idle circuit (Engine Control Module or InPower ETM Series Fast Idle Electronic Throttle) Offered by InPO WER Off Road Engineering the systems people InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Ground +12 volts @ 15 amps when in latched state Page 2 of 2 Application Bulletin AB-10A Version: A Date: June 18, 2007 InPOWER VCM Series the systems people Application Bulletin Remote Controlled Compartment Light Circuit Latching circuit toggles vehicle compartment lights on and off from multiple remote switches. Product Information InPower Model: VCM-01 Alternating Latching Solid State Relay, 12 volt Description: The VCM-01 module contains two inputs, one actuated by a transition to +12 volts and one actuated by a transition to ground. The module’s output will toggle to the opposite state when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. The module’s output is +12 volts @ 15 amps when in the latched state. Upon power up the output is in the unlatched state. Documentation: Product Data Sheet PDS-58 Operation Operating a remote switch the first time will cause the VCM-01 module to set its output to the latched state (output terminal 30 at +12 volts). When set the output will power the compartment lights. Operating a remote switch a second time will reset the VCM-01 module’s output to the unlatched state (no power on terminal 30). When powering up (applying +12 volts on terminal 86) the VCM-01 module will be in the unlatched state (no power on terminal 30). Application Wiring Diagram 1 (Remote switch connected to ground) Remote Switches (Momentary) Location 1 Input B Ground 87 Location 2 86 +12 Volts Ground InPower VCM-01 +12 Volt Alternating Latching Solid State Relay 87a 85 30 Output Compartment Lights Ground Ground +12 volts @ 15 amps when in latched state Ground Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 1 of 2 Application Bulletin AB-11A Version: A Date: June 26, 2007 InPOWER VCM Series the systems people Application Bulletin Application Wiring Diagram 2 (Remote switches connected to +12 volts) Remote Switches (Momentary) Location 1 Input A +12 Volts 87 Location 2 86 +12 Volts +12 Volts InPower VCM-01 +12 Volt Alternating Latching Solid State Relay 87a 85 30 Output Compartment Lights Ground +12 volts @ 15 amps when in latched state Ground Ground Application Wiring Diagram 3 (Two remote switches, connected to +12 volts and ground) Remote Switches (Momentary) Location 1 Input A +12 Volts Input B 87 Location 2 86 +12 Volts Ground InPower VCM-01 +12 Volt Alternating Latching Solid State Relay 87a 85 30 Output Compartment Lights Ground Ground +12 volts @ 15 amps when in latched state Ground Offered by InPO WER Off Road Engineering the systems people InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 2 of 2 Application Bulletin AB-11A Version: A Date: June 26, 2007 InPOWER VCM Series the systems people Application Bulletin Delayed 12 Volt Circuit Operation Adjustable on-delay timer function provides delayed circuit operation.. Product Information InPower Model: VCM-03.X Time Delay Solid State Relay, On-Delay Description: The VCM-03.X is a solid state adjustable on-delay timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. When an input is applied and maintained, the timer will start. When the timer expires the output will be activated. The output will remain activated until both inputs are open (cleared). The time period is adjustable with a single turn potentiometer. Four time ranges are available: 0-10 seconds, 0-60 seconds, 0-3 Minutes, and 0-10 minutes. Available Models: VCM-03.1 VCM-03.2 VCM-03.3 VCM-03.4 Documentation: Product Data Sheet PDS-59 0 - 10 Seconds Time Range 0 - 60 Seconds Time Range 0 - 3 Minutes Time Range 0 - 10 Minutes Time Range Operation 1. Operate Switch to On position. The timer is started (The time period is adjustable). 2. When the timer expires the Output Circuit is activated via the VCM-03.X output (terminal 30). 3. When Switch is set to Off position, the Output Circuit is deactivated and timer is reset. Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 1 of 2 Application Bulletin AB-12A Version: A Date: June 26, 2007 InPOWER VCM Series the systems people Application Bulletin Application Wiring Diagram (Control switch with delayed output) Input A Control Switch Off 87 +12 Volts On 86 +12 Volts Output 87a InPower VCM-03.1 On-Delay Solid State Time Delay Relay 85 30 TIME AD J Timer Adjustment: CCW = Minimum Time CW = Maximum Time Ground Output Circuit +12 volts @ 15 amps Timing Diagram Open Control Switch Closed +12V Output Circuit On-Delay Time Period 0V Offered by InPO WER Off Road Engineering the systems people InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 2 of 2 Application Bulletin AB-12A Version: A Date: June 26, 2007 InPOWER VCM Series the systems people Application Bulletin Bus Egress Light Timer Circuit Operates a bus door egress light when entry door is open, and for a timed period (adjustable) after the door is closed. Product Information InPower Model: VCM-04.X Time Delay Solid State Relay, Off-Delay Description: The VCM-04.X module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. When an input is applied the output will immediately be activated. When the input is removed, the timer will start and the output will remain activated. When the timer expires the output will deactivate. The time period is adjustable with a single turn potentiometer. Four time ranges are available: 0-10 seconds, 060 seconds, 0-3 Minutes, and 0-10 minutes. Available Models: VCM-04.1 VCM-04.2 VCM-04.3 VCM-04.4 VCM-04.5 VCM-04.005S Documentation: Product Data Sheet PDS-60 0 - 10 Seconds Time Range 0 - 60 Seconds Time Range 0 - 3 Minutes Time Range 0 - 10 Minutes Time Range 0 - 60 Minutes Time Range Fixed 5 Seconds Operation 1. Door opens. Egress light turns on immediately via VCM-04.X output (terminal 30). 2. Door closes. Timer is started. 3. Timer expires and egress light turns off. Application Wiring Diagram 1 (Entry door switch connected to +12 volts) Entry Door Switch Input A Closed +12 Volts 87 Open 86 +12 Volts 30 Egress Light 87a 85 InPower VCM-04.1 Off-Delay Solid State Time Delay Relay (0 to 10 Seconds) TIME AD J Timer Adjustment: CCW = Minimum Time CW = Maximum Time +12 volts @ 15 amps Ground Ground Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 1 of 2 Application Bulletin AB-13B Version: B Date: January 3, 2008 InPOWER VCM Series the systems people Application Bulletin Application Wiring Diagram 2 (Entry door switch connected to ground) Input B Entry Door Switch Closed 87 Ground Open 86 +12 Volts 85 30 Egress Light 87a InPower VCM-04.1 Off-Delay Solid State Time Delay Relay (0 to 10 Seconds) TIME AD J Timer Adjustment: CCW = Minimum Time CW = Maximum Time +12 volts @ 15 amps Ground Ground Timing Diagram: Open Door Switch Closed Time Period* +12V Egress Light 0V * On model VCM-04.1, the time period is adjustable from 0 to 10 seconds. Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 2 of 2 Application Bulletin AB-13B Version: B Date: January 3, 2008 InPOWER VCM Series the systems people Application Bulletin Bus Mirror Heater Timer Circuit Circuit provides an adjustable timed power output to the mirror heating element when activated by the control switch. Product Information InPower Model: VCM-05.X Time Delay Solid State Relay, One-Shot Description: The VCM-05.X is a solid state adjustable one-shot timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. If the module is not already in a time-out sequence, its output will be activated for the adjustable time period when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. Once the timer has started, and the output activated, it will not be affected by the state of the input. The time period is adjustable with a single turn potentiometer. Time ranges available include: 0-10 seconds, 0-60 seconds, 0-3 minutes, 0-10 minutes, 0-60 Minutes, and fixed 120 seconds. Available Models: VCM-05.1 VCM-05.2 VCM-05.3 VCM-05.4 VCM-05.5 VCM-05.120S Documentation: Product Data Sheet PDS-61 0 - 10 Seconds Time Range 0 - 60 Seconds Time Range 0 - 3 Minutes Time Range 0 - 10 Minutes Time Range 0 - 60 Minutes Time Range Fixed 120 Seconds Operation 1. Control Switch is turned on (This may be a momentary push button switch or a 2-position maintained switch). 2. The mirror heating element is powered by the VCM-05.X output (terminal 30). The VCM-05.X keeps power on the heating element for a fixed period of time (VCM-5.X time setting) regardless of the Control Switch being in the open or closed position. Application Wiring Diagram 1 (Control switch connected to +12 volts) Input A Control Switch Off +12 Volts 87 On 86 +12 Volts Output 87a InPower VCM-05.4 Off-Delay Solid State Time Delay Relay (0 to 10 Minutes) 85 30 TIME AD J Bus Mirror Heating Element Ground Ground Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Timer Adjustment: CCW = Minimum Time CW = Maximum Time +12 volts @ 15 amps Page 1 of 2 Application Bulletin AB-14C Version: B Date: January 3, 2008 InPOWER VCM Series the systems people Application Bulletin Application Wiring Diagram 2 (Control switch connected to ground) Input B Control Switch Off 87 Ground On 86 +12 Volts 85 30 Output 87a InPower VCM-05.4 Off-Delay Solid State Time Delay Relay (0 to 10 Minutes) Timer Adjustment: CCW = Minimum Time CW = Maximum Time TIME AD J Bus Mirror Heating Element +12 volts @ 15 amps Ground Application Wiring Diagram 3 (Control switches connected to ground and +12 volts) Control Switch Input A Off Input B +12 Volts On Control Switch 87 Off 86 +12 Volts 87a InPower VCM-05.4 Off-Delay Solid State Time Delay Relay (0 to 10 Minutes) 85 Ground On Output 30 TIME AD J Bus Mirror Timer Adjustment: CCW = Minimum Time CW = Maximum Time Ground Heating Element +12 volts @ 15 amps Ground Timing Diagram Input A Input B +12 V 0V +12 V 0V Time This timing diagram shows a short duration (e.g., Momentary) control switch operation. The switch activation starts the timed output pulse. +12 V Output Input A Input B 0V +12 V 0V +12 V 0V Time Output +12 V This timing diagram shows a long duration control switch operation. The leading edge of the switch activation activates the timed output pulse. The timed output will end regardless of the control switch being on or off. 0V Offered by InPO WER Off Road the systems peopleEngineering InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 www.InPowerDirect.com © Copyright 2007 949.581.2991 InPower LLC Page 2 of 2 Application Bulletin AB-14C Version: B Date: January 3, 2008 InPOWER VCM Series the systems people Application Bulletin Bus Stop Request Circuit Operates a bus stop request indicator and timed buzzer from the pull cord switch and resets when the entry door is opened. Product Information InPower Model: VCM-05.X Time Delay Solid State Relay, One-Shot Description: The VCM-05.X is a solid state adjustable one-shot timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. If the module is not already in a time-out sequence, its output will be activated for the adjustable time period when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. Once the timer has started, and the output activated, it will not be affected by the state of the input. The time period is adjustable with a single turn potentiometer. Four time ranges are available: 0-10 seconds, 0-60 seconds, 0-3 minutes, and 0-10 minutes. Available Models: VCM-05.1 VCM-05.2 VCM-05.3 VCM-05.4 Documentation: Product Data Sheet PDS-61 0 - 10 Seconds Time Range 0 - 60 Seconds Time Range 0 - 3 Minutes Time Range 0 - 10 Minutes Time Range Operation 1. Door Switch is closed. Pull Cord Switch is operated. Relays A and B operate and stay latched. 2. Stop Request Indicator is powered. VCM-05.X powers buzzer immediately and keeps it powered for the VCM-05.X time period. Buzzer goes off and Stop request Indicator stays on. 3. When Door Switch goes to Door Open position, Step Light turns on and Relay A, Relay B and VCM-05.X are reset (turned off). 4. When Door Switch goes to Door Closed position the sequence can repeat. Offered by InPO WER Off Road Engineering the systems people InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 1 of 2 Application Bulletin AB-15A Version: A Date: June 26, 2007 InPOWER VCM Series the systems people Application Bulletin Application Wiring Diagram Entry Door Switch Step Light Open +12 Volts Ground Closed Pull Cord Switch Stop Request Indicator Ground 87 87 87a 86 InPower VCM-05.1 One-Shot Solid State Time Delay Relay 85 86 Relay A* 30 85 30 TIME A DJ Relay B* Ground 87 85 86 Timer Adjustment: CCW = Minimum Time CW = Maximum Time (Set for 2-4 seconds) +12 volts @ 15 amps Buzzer 30 Ground *12 Volt Automotive Relay Ground Offered by InPO WER Off Road Engineering the systems people InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 2 of 2 Application Bulletin AB-15A Version: A Date: June 26, 2007 InPOWER VCM Series the systems people Application Bulletin Bus Alternating Warning Light Flasher Circuit Product Information InPower Model: VCM-08 Dual 15 Amp Alternating Lamp Flasher Description: The VCS-08 flasher is a completely solid state dual output alternating warning lamp flasher. Its outputs are rated at +12 volts @ 15 amps each, and are designed to operate high in-rush current halogen and incandescent lamps, as well as LED lights. When a ground is applied to the input, the outputs will alternately flash at a rate of 75 cycles per minute at a 50% duty cycle. The solid state outputs are a unique design that will automatically shut off if an over current or short circuit fault occurs. If a fault shut down occurs on one output the other output will remain operational. Documentation: Product Data Sheet PDS-62 Operation 1. Flasher Switch to On position. 2. Output A and Output B alternately flash at a rate of 75 flashes per minute. Application Wiring Diagram Flasher Switch InPower VCM-08 Dual 15 Amp Output Alternating Lamp Flasher Off On Ground Front Warning Lights Input 87 86 Output B +12 volts @ 15 amps 85 30 Output A Ground +12 volts @ 15 amps Rear Warning Lights +12 Volts Ground Timing Diagram +12 V 0V +12 V Output A 0V +12 V Output B 0V Input Offered by InPO WER Off Road Engineering the systems people InPOWER LLC 3555 Africa Road Galena, Ohio 43021 U.S.A (866)548-0965 949.581.2991 www.InPowerDirect.com © Copyright 2007 InPower LLC Page 1 of 1 Application Bulletin AB-16A Version: A Date: June 26, 2007 SOLUTIONS you can count on School Bus Egress Lamp Timer • Automatically Activates Exterior Egress Lamp • Adjustable Time Off Delay After Door is Closed • Timer Delay Adjustable from 0-10 Seconds • Controls up to 15 Amps InPOWER the systems people www.inpowerdirect.com www.offroadengineering.com 740.548.0965 (949) 581 2991 InPOWER VCM Series the systems people Vehicle Control Modules VCM-04.X Time Delay Solid State Relay, Off-Delay InPower’s VCM Series Vehicle Control Modules are a set of “tools” for the designers of vehicle electrical control systems. These solid state modules are designed to withstand the environments typically found on trucks, emergency vehicles, buses, coaches and speciality vehicles, and are available in a variety of standard and custom configurations and functions. Technical Description The InPower VCM-04.X is a completely solid state adjustable off-delay timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. Key Features • 100% Solid State Construction • Standard Automotive Relay Pin Format • 12 Volt 15 Amp Solid State Output • Compact Size with Panel-Mount Bracket • Dual Inputs - Ground and +12 Volt • Durable Metal Case VCM-04.X Time Delay Solid State Relay, Off-Delay Timing Diagram Specifications Power Input (86): Ground (85): +8 to 16 Vdc @ 15 amps Connection to vehicle ground (Battery Negative) External contact closure to +12 volts External contact closure to ground +12 volts @ 15 amps Input A (87a): Input B (87): Module Output (30): Mechanical Weight: Operating Temperature: Dimensions: Time Range 0 - 10 Sec. 0 - 60 Sec. 0 - 3 Min. 0 - 10 Min. 0 - 60 Min. 5 Sec. Fixed 0V Time Output +12 V 0V +12 V Input B 0.10 lbs. -40° C to +85° C 1.75” H x 2.30” W x 1.25” D 0V Time Output +12 V 0V Installation 1. When an input is applied the output will immediately be activated. When the input is removed, the timer will start and the output will remain activated. When the timer expires the output will deactivate. The time period is adjustable with a single turn potentiometer. Time ranges available include: 0-10 seconds, 0-60 seconds, 0-3 minutes, 0-10 minutes, 0-60 minutes, and fixed 5 seconds. 2. 3. 4. 5. 6. 7. The output will be activated when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. When the applied input has cleared, and its counterpart input is also clear, the timer will start. When the timer has expired the output will be deactivated and the operation is complete. The output is rated at +12 volts @ 15 amps and provides over current and short circuit shut down protection. 8. We recommend that the module be installed by a person trained and skilled in vehicle electrical systems. The installation should comply with SAE (Society of Automotive Engineers) and the vehicle manufacturer’s electrical wiring procedures (e.g., Ford, General Motors, etc.). The module should be installed on the inside of the vehicle in a dry and protected environment. For optimum power output performance the product should be mounted to a metal surface. Do not connect loads to the output that will exceed the output current rating of the module. The 12 volt power input (86) must be from a properly fused +12 volt power source. Wiring must be of the proper gage and type to handle the intended load currents. We recommend the use of insulated 1/4 inch female blade terminals that connect to the terminals on the module. Be sure to properly crimp these terminals. Do not solder wires directly to the module terminals. If you are experiencing problems with the installation or need troubleshooting assistance, contact InPower Customer Service at 740-548-0965. Outline Drawing Ordering Guide Model VCM-04.1 VCM-04.2 VCM-04.3 VCM-04.4 VCM-04.5 VCM-04.005S +12 V Input A 0.35 Description Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs Solid state off-delay time delay relay with +12 volt @ 15 amp output and two inputs 1.25 0.35 1.80 2.30 Wiring Diagram InPower VCM-04.X Time Adjustment Terminal Layout 87a 30 Input A 87 87a Input B 85 1.75 30 Switch 85 Vehicle Ground (Battery Negative) 86 +12 Volt 15 Amp Fused Power Source Control +12 Volts Electronic Power Switch 0.063 All dimensions in inches. Not to scale. InPOWER LLC 30 Output +12 Volts @ 15 Amps PATENT PENDING 86 Ground Ground 85 Switch +12 Volts Microprocessor Controller 87 86 87 87a LOAD Ground Product Data Sheet PDS-60C Offered by: 3555 Africa Road Galena, Ohio 43021 Tel 740-548-0965 Fax 740-548-2302 www.InPowerDirect.com PDS08-8262 PDS-60C 010308 Copyright2008 2002InPOWER InPOWERLLC LLC ©©Copyright Specifications subjecttotochange changewithout withoutnotice. notice. Specifications subject www.offroadengineering.com (949) 581 2991 • Fast Idle Throttles • Solid State DC Contactors • Instruments & Current Sensors • Warning Light Flashers • FMVSS Interlocks • Vehicle Control Modules For more information visit us at www.InPowerLLC.com For more information visit us at www.offroadengineering.com or call 949.581.2991 SOLUTIONS you can count on SOLUTIONS you can count on Automatic Mirror Heater Shut off Timer • • • • Prevents Mirror Damage Minimizes Battery Drain Adjustable Shut off Time Delay Easy to Install www.inpowerdirect.com www.offroadengineering.com 740.548.0965 (949) 581 2991 Automatic Mirror Heater Shut off Timer • • • • Prevents Mirror Damage Minimizes Battery Drain Adjustable Shut off Time Delay Easy to Install www.inpowerdirect.com 740.548.0965 InPOWER the systems people VCM - 05 Series One-Shot Time Delay InPOWER the systems people VCM - 05 Series One-Shot Time Delay InPower Model: VCM-05.X Time Delay Solid State Relay, One-Shot InPower Model: VCM-05.X Time Delay Solid State Relay, One-Shot Description: The VCM-0.X is a solid state adjustable one-shot timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. If the module is not already in a time-out sequence, it’s output will be activated for the adjustable time period when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. Once the timer has started, and the output is activated, it will not be affected by the state of the input. The time period is adjustable with a single turn potentiometer. Five time ranges are available: 0-10 seconds, 0-60 seconds, 0-3 minutes, 0-10 minutes, and 120 seconds non-adjustable. Description: The VCM-0.X is a solid state adjustable one-shot timer relay with a single +12 volt @ 15 amp output. The module has two inputs, one actuated by a transition to +12 volts (Input A) and one actuated by a transition to ground (Input B). The two inputs operate as a logical “Exclusive OR” so that either input can cause the timer to operate. If the module is not already in a time-out sequence, it’s output will be activated for the adjustable time period when +12 volts is applied to Input A while Input B is open, or when ground is applied to Input B while Input A is open. Once the timer has started, and the output is activated, it will not be affected by the state of the input. The time period is adjustable with a single turn potentiometer. Five time ranges are available: 0-10 seconds, 0-60 seconds, 0-3 minutes, 0-10 minutes, and 120 seconds non-adjustable. Available Models: VCM-05.1 Available Models: VCM-05.1 0 - 10 Seconds Time Range 0 - 60 Seconds Time Range 0 - 3 Minutes Time Range 0 - 10 Minutes Time Range 120 Second Non-Adjustable VCM-05.2 VCM-05.3 VCM-05.4 VCM-05.120S VCM-05.2 VCM-05.3 VCM-05.4 VCM-05.120S Wiring Diagram: 0 - 10 Seconds Time Range 0 - 60 Seconds Time Range 0 - 3 Minutes Time Range 0 - 10 Minutes Time Range 120 Second Non-Adjustable Wiring Diagram: Switch Input A + 12 Volts Switch Input B Ground + 12 Volts Bus Mirror Input A + 12 Volts 87 a Switch 87 VCM - 05 Input B Ground + 12 Volts 86 Output Heating Element Switch Ground Bus Mirror 30 Time Adjust Ground 87 VCM - 05 86 Output Ground 85 30 Time Adjust 85 Ground InPOWER www.offroadengineering.com (949) 581 2991 Heating Element 87 a 3555 Africa Road - Galena, Ohio 43021 Tel: 740.548.0965 Fax: 740.548.2302 www.inpowerdirect.com InPOWER 3555 Africa Road - Galena, Ohio 43021 Tel: 740.548.0965 Fax: 740.548.2302 www.inpowerdirect.com