Vandal Resistant Wraparound / 1, 2, 3 or 4-Lamp T8
Project Information
Project Name
Type
Catalog No.
Date
Construction
Heavy 16 gauge cold rolled steel housing.
Ballasts
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated
A, unless otherwise specified. CEE NEMA Premium
compliant.
Features
• Ideal for vandal-prone areas, such as schools, hallways,
dormitories, restrooms, bus stops, and locker rooms
• Effective, secure illumination mounts to ceilings or walls
• Rugged, 16 gauge heavy duty steel housing
• Diffuser is UV stabilized .130" thick, one-piece, prismatic
polycarbonate for high-impact protection
• Formed end cap welded to housing for additional strength
• Wireway extends below lamp to protect lamp for impact
breakage
• White powder coat finish painted after fabrication
• For ceiling, wall, or pendant–individual or in continuous row
• Six tamper-resistant screws protect against unauthorized
entry
• Wet location (covered ceiling mount), Damp Location (Wall
Mount)
Electrical
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
Finish
Painted parts are treated with a five stage
phosphate bonding process and finished with a high
reflectance baked white enamel.
Shielding
Diffuser is of 0.130" thick clear prismatic
polycarbonate material.
Certification
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
fixtures labeled UL 924.
Ordering Information
4
VR
Example VRW4-332-3EU
32
–
Model
width
Size
No. of Lamps
VR Vandal
Resistant
Wraparound
N Narrow (5 1⁄8")
M Medium (8 5⁄16")
W Wide (12 5⁄16")
4 4'
1
2
3
4
One (VRN)
Two (VRN, VRM)
Three (VRW)
Four (VRW)
U
–
Lamp Type
Ballast
32 4', T8: 32, 30,
28 or 25 Watt
E Electronic T8,
Instant Start
3E 3-Lamp Electronic T8,
Instant Start
4E 4-Lamp Electronic T8,
Instant Start
–
Voltage
U 120V-277V
Options
EL Emergency Battery Pack
NYC NYC Compliant
NYCU NYC Compliant, Union Label
Accessories
(Order Separately)
VDR
GLRK
S18
SS18
Page 1/2 Rev. 01/19/12
Tamper Resistant Screwdriver
Fast Blow Fuse Kit
18" Stem, Canopy
18" Swivel Stem - 45° Swivel
Wraps / vr
© 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com
vr
Vandal Resistant Wraparound / 1, 2, 3 or 4-Lamp T8
Photometric Data AVG. Luminance (Candela/Sq. M.)
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Mounting
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
7036
6275
5688
4837
3884
3071
2410
1942
1582
1365
1332
1221
7036
6547
5804
4936
4124
3381
2787
2412
2215
2129
1951
1795
7036
6548
5669
4848
4251
3715
3155
2728
2631
2674
2758
2804
56
Surface
0º = 90 90º = 90
Zonal Lumen Summary
0º = 1.21 90º = 1.46
Length: 3.96
Width: 0.44
Height: 0.22
Luminaire Data
Luminaire
7036
6414
5625
4594
3732
3273
2806
2260
1786
1305
1136
954
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
7036
6499
5584
4753
4240
3864
3450
3061
2968
2948
3098
3399
Lumens % Lamp % Fixt.
953
1588
2606
3310
497
613
736
760
4071
17.0
28.4
46.5
59.1
8.9
11.0
13.1
13.6
72.7
23.4
39.0
64.0
81.3
12.2
15.1
18.1
18.7
100.0
Coefficients of Utilization (%)
RC
RW
1
2
3
4
5
6
7
8
9
10
70
76
69
63
58
53
49
46
42
40
37
80
50 30
72 69
63 58
55 50
49 43
44 38
40 34
36 30
33 27
30 24
28 22
10
66
54
45
38
33
29
26
23
21
19
70
72
66
60
55
51
47
44
41
38
36
70
50 30
69 66
60 56
53 48
47 42
43 37
38 33
35 29
32 26
29 24
27 22
10
63
52
44
37
32
28
25
22
20
18
50
63
56
49
44
40
36
33
30
27
25
50
30
61
52
45
39
35
31
28
25
23
21
Indoor Candela Plot
10
59
49
41
36
31
27
24
21
19
18
0
0
48
41
35
30
26
23
20
18
16
15
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Energy Data
Total Luminaire Efficiency
72.7%
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
67
Noncompliant
$3.58 based on 3000
hrs. and $0.08 per KWH
AVG. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
VRW4-432-4E
Vandal Resistant
Wraparound
16" × 48" 4-Lamp
with Prismatic
Polycarbonate Lens
B432I120RH
0.88
F32T8
2800
106
Surface
0º = 90 90º = 90
0º = 1.22 90º = 1.37
Length: 3.96
Width: 1.29
Height: 0.19
0.0 22.5 45.0 67.5 90.0
0
30
40
45
50
55
60
65
70
75
80
85
5976
5526
4963
4086
3212
2671
2253
1921
1617
1326
1049
890
5976
5539
5146
4288
3293
2640
2024
1521
1269
1118
1135
1000
5976
5769
5315
4265
3479
2823
2136
1604
1340
1268
1293
1285
5976
5886
5226
4246
3588
3010
2341
1768
1466
1384
1481
1617
5976
5958
5175
4099
3575
3223
2743
2205
1785
1476
1567
1964
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
Lumens % Lamp % Fixt.
2270
3737
5815
6678
327
370
417
429
7107
20.3
33.4
51.9
59.6
2.9
3.3
3.7
3.8
63.5
31.9
52.6
81.8
94.0
4.6
5.2
5.9
6.0
100.0
RCR
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Mounting
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
0
30
40
45
50
55
60
65
70
75
80
85
VRN4-232-E
Vandal Resistant
Wraparound
5" × 48" 2-Lamp
with Prismatic
Polycarbonate
Refractor
E232PI120GO1
0.92
F32T8
2800
Average Luminance Angle
Luminaire
Average Luminance Angle
Luminaire Data
Test HP07297 Test Date 7/29/1997
RCR
0.0 22.5 45.0 67.5 90.0
RC
RW
1
2
3
4
5
6
7
8
9
10
70
69
63
58
54
50
46
43
40
38
35
80
50 30
66 64
59 55
52 48
47 42
42 37
38 33
35 30
32 27
30 25
27 23
10
61
52
44
38
33
29
26
24
21
19
70
67
61
57
52
48
45
42
39
36
34
70
50 30
64 62
57 54
51 47
46 41
41 37
38 33
34 29
31 27
29 24
27 22
10
60
51
43
38
33
29
26
23
21
19
50
61
54
49
44
40
36
33
30
28
26
50
30
59
51
45
40
35
32
29
26
24
22
Test HP07299 Test Date 7/31/1997
10
58
49
42
37
32
29
26
23
21
19
0
0
51
44
38
34
30
26
23
21
19
17
Indoor Candela Plot
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Energy Data
Total Luminaire Efficiency
63.5%
Luminaire Efficacy Rating (LER)
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
59
Noncompliant
$4.07 based on 3000
hrs. and $0.08 per KWH
Dimensional Data
483/4"
24"
VRN (Narrow)
51/8" Wide
51/8"
51/8"
2" Dia. KO
33/4"
VRN
1/2" Dia. KO
483/4"
24"
125/16"
VRM (Medium)
85/16" Wide
23/4"
85/16"
85/16"
11/5" Dia. KO & Keyholes
23/4"
VRM
VRW
483/4"
24"
7/8" Dia. KO
VRW (Wide)
125/16" Wide
125/16"
11/2" Dia. KO & Keyholes
7/8" Dia. KO
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 01/19/12
Wraps / vr
© 2009 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change
specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com