J.J. BCN INTERNACIONAL,S.A. series J3C multivoltage reversible electric actuators J3C Actuador eléctrico reversible multivoltage J3C J3C is the new concept ¼ turn multivoltage electric actuator that finally offers all the solutions that utilize the reversibles electric actuators for the operation and control of the valves. J+J following as always our politics of improvement and incorporation of the new products in the valve automation market we have obtained a product where operation security, economy in cost and releases life has been the principal objective. J3C es el nuevo concepto de actuador eléctrico multivoltaje rotativo ¼ vuelta que definitivamente ofrece todas las soluciones que precisan los modernos sistemas de proceso que utilizan actuadores eléctricos reversibles para el accionamiento y control de válvulas de bola, mariposa, grifos de macho, “dumpers”, etc. ALL J3C TYPES AND MODELS have the following STANDARD features: ATC AUTOMATIC TEMPERATURE CONTROL: An internal 4 W thermostatically controlled anticondensation heater maintains the internals between: +20ºC and +30ºC, (68ºF – 86ºF) eliminating the possibility of damage by condensation. AVS AUTOVOLTAGE SENSING: The J3C actuators are, within the voltages ranges specified for “L” or “H” series, multi-voltage capable and make automatic internal adjustments to ensure the actuator operates, irrespective of the power supply “L” series operates from 12 to 24 VAC or 12 to 24 V DC “H” series operates from 85 to 250 VAC or DC ETL ELECTRONIC TORQUE LIMITER: Continuous electric monitoring of the motor produces smooth operation and accurate control of the motor consumption up to the maximum permissible torque. Should the maximum torque be exceeded, the ETL automatically cuts the power to the motor to prevent damage to the actuator, and automatically relaxes the gearbox to allow simple operation of the manual override. MO MANUAL OVERRIDE: For emergency manual operation, operated by a selector lever on the side of the actuator, with automatic motor power tripping when selected. PES PROTECTED ELECTRICAL SUPPLY: The J3 accepts the same wiring connection for either AC or DC operation (grey connector) External DIN plugs eliminate the need to remove the actuator’s cover to connect. VCO VISUAL CONTROL OF OPERATION: A constantly lid of the external LED indicates the normal operation of the actuator. -A flashing LED frequency 1 advises that the actuator’s torque limiter has been exceeded and the ETL has activated. -A flashing LED frequency 2 advises that the actuator is in MANUAL position. -To see other flashing frequencies VFC VOLT FREE CONTACS: 1 set of open and closed volt free contacts are provided. ACTUADOR ELÉCTRICO ELECTRIC ACTUATOR En J+J siguiendo, como siempre, nuestros objetivos hemos conseguido un producto donde la seguridad de funcionamiento, economía en costo y larga vida han sido cuidados hasta el más mínimo detalle. R TODOS LOS MODELOS J3C series “L” y “H” incorporan el siguiente equipo base. ATC CONTROL TÉRMICO DE LA TEMPERATURA: Calefactor de 4 W controlado termostáticamente para el mantenimiento de la temperatura interior entre 20º y 30ºC (68º F – 86º F) y evitar así daños por condensación. AVS MULTIVOLTAJE: Alimentación eléctrica corriente alterna o continua indistintamente: Serie “L” : de 12 a 24 VAC o 12 a 24 VDC Serie “H” : de 85 a 250 VAC o DC ETL CONTROL ELECTRÓNICO DE PAR: El continuo control electrónico produce un funcionamiento suave así como un cuidadoso control del consumo del motor hasta el máximo par permitido. Cuando éste es excedido, el sistema ETL suspende la alimentación eléctrica para prevenir posibles daños al actuador y libera la presión de los engranajes para facilitar el accionamiento del mando manual de emergencia. MO MANDO MANUAL DE EMERGENCIA: Situando la palanca en posición manual el motor queda automáticamente desconectado del tren de engranajes y puede accionarse manualmente la válvula. PES CONFIGURACIÓN CONEXIÓN AC / DC: Ambas opciones son posibles para el mismo actuador simplemente debe conectarse la alimentación eléctrica (conector color gris) según el esquema de conexiones que figura en la etiqueta exterior del actuador. Conectores externos DIN facilitan la conexión eléctrica al actuador sin necesidad de abrir la tapa del mismo. Distribuidor Distributor VCO CONTROL VISUAL DE OPERACIÓN: Un LED externo constantemente iluminado nos indica el normal funcionamiento del actuador. -LED externo destellante frecuencia 1 indica que el máximo par permitido ha sido sobrepasado. -LED externo destellante frecuencia 2 indica que el actuador está en posición “manual”. J.J. BCN INTERNACIONAL, S.A se reserva el derecho de modificación del diseño, construcción o cualquier detalle técnico de los productos que figuran en este catalogo sin previo aviso. J.J. BCN INTERNACIONAL, S.A. reserves the right to change or modify the design, technical details or construction of the products of this catalogue without prior notice. -Ver otras frecuencias de destello VFC CONTACTOS AUXILIARES: 2 contactos (micro interruptores) adicionales para transmisión de señal. Ej. : Señalización de posición. 2-2012 / 2000 R J+J ELECTRIC POWER R ESPECIFICACIONES / SPECIFICATIONS Mod. J3C L-20 VOLTAJE VOLTAGE Mod. J3C H-20 Mod. J3C L-35 12 a/to 24 VAC/VDC 85 a/to 240 VAC/VDC -0/+5% CARACTERÍSTICAS GENERALES / TECHNICAL DATA Mod. J3C H-35 Mod. J3C L-55 12 a/to 24 VAC/VDC 85 a/to 240 VAC/VDC -0/+5% Mod. J3C H-55 Mod. J3C L-85 12 a/to 24 VAC/VDC 85 a/to 240 VAC/VDC -0/+5% -0/+5% Mod. J3C H-85 12 seg 12 sec 11 seg 11 sec 12 seg 12 sec 11 seg 11 sec 16 seg 16 sec 14 seg 14 sec 35 seg 35 sec 30 seg 30 sec PAR MÁXIMO ARRANQUE MAXIMUM TORQUE BREAK 25 Nm 221 lb/in 25 Nm 221 lb/in 38 Nm 359,3 lb/in 38 Nm 359,3 lb/in 60 Nm 530 lb/in 60Nm 530 lb/in 90 Nm 796 lb/in 90 Nm 796,3 lb/in PAR MANIOBRA EN OPERACIÓN MAXIMUM OPERATIONAL TORQUE 20 Nm 177 lb/in 20 Nm 177 lb/in 35 Nm 309 lb/in 35 Nm 309 lb/in 55 Nm 486 lb/in 55Nm 486 lb/in 85 Nm 752 lb/in 85 Nm 752 lb/in 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 75% 90º a 270º 90º to 270º 90º a 270º 90º to 270º 90º a 270º 90º to 270º 90º a 270º 90º to 270º 90º a 270º 90º to 270º 90º a 270º 90º to 270º 90º a 270º 90º to 270º 90º a 270º 90º to 270º 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 4 SPDT micro 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W 3,5 W DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 DIN 43650 ISO440 & C192 IP-67 IP-67 IP-67 IP-67 IP-67 IP-67 IP-67 IP-67 -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F -20ºC + 70ºC -4º + 158º F CONSUMO A PAR MÁXIMO +/-5% 24 VAC 787,5 mA - 18,9 W 24 VDC 913,5 mA - 21,9 W 110VAC 168 mA - 18,5 W 220VAC 84 mA - 18,5 W 24 VAC 1071mA - 25,7 W 24 VDC 1491 mA - 35,8W 110 VAC 231 mA - 25,4 W 220 VA 115,5 mA - 26,6 W 24 VAC 1239 mA - 29,7 W 110 VAC 231 mA - 25,4 W 24 VDC 1428 mA - 34,3W 220 VDC 115,5 mA - 26,6 W 24 VAC 934,5 mA - 22,4 W 24 VDC 1176 mA - 28,2 W 110 VAC 168 mA - 18,5 W 220 VDC 84 mA - 18,5W CONSUMPTION AT MAXIMUN TORQUE +/-5% 24 VAC 787,5 mA - 18,9 W 24 VDC 913,5 mA - 21,9 W 110VAC 168 mA -18,5 W 220VAC 84 mA -18,5 W 24 VAC 1071 mA - 25,7 W 24 VDC 1491 mA - 35,8 W 110 VAC 231mA -25,4 W 220 VAC 115,5 mA -26,6W 24 VAC 1239 mA - 29,7 W 110 VAC 231 mA - 25,4W 24 VDC 1428 mA - 34,3 W 220 VDC 115,5 mA - 26,6 W 24 VAC 934,5 mA - 22,4 W 24 VDC 1176 mA - 28,2W 110 VAC 168 mA - 18,5 W 220 VDC 84 mA - 18,5W 1,8 Kg 1,8 Kg 1,8 Kg 1,8 Kg 1,9 Kg 1,9 Kg TIEMPO MANIOBRA EN VACÍO OPERATION TIME UNLOAD TIEMPO BAJO TENSIÓN % DUTY RATING % ÁNGULO MANIOBRA WORKING ANGLE INTERRUPTOR FINAL DE CARRERA LIMIT SWITCH RESISTENCIA CALEFACTORA HEATER CONECTORES DIN PLUGS PROTECCIÓN IEC 60529 IP RATING IEC 60529 TEMPERATURA TEMPERATURE PESO (Kg.) WEIGHT (Kg.) J3C L/H-20 & 35 J3C L/H-55 1,9 Kg 1,9 Kg 2,4 Kg 2,4 Kg i 12 a/to 24 VAC/VDC 85 a/to 240 VAC/VDC -0/+5% -0/+5% 2,4 Kg 2,4 Kg 3 Kg 3 Kg o ON - OFF N L VAC ANCLAJE J3C 20 y J3C 35: ISO5211 Multibrida estándar F03/F04/F05 J3C 55 y J3C 85: ISO5211 Multibrida estándar F05/F07 FASTENING DIN3337 Conexión hembra estándar J3C 20 y J3C 35: doble cuadrado 14 mm J3C 55 y J3C 85: doble cuadrado 17 mm DIN3337 Standard female drive connection J3C 20 & J3C 35 : double square 14 mm J3C 55 & J3C 85 : double square 17 mm Opciones bajo demanda: J3C 20 y J3C 35: doble cuadrado 9 mm y 11 mm J3C 55 y J3C85: doble cuadrado 11 mm y 14 mm Female drive connection under request: J3C 20 & J3C 35: double square 9 mm & 11 mm J3C 55 & J3C 85: double square 11 mm & 14 mm OPCIONES TODOS MODELOS: KIt posicionador digital DPS2005: 0 - 20 mA, 4 - 20 mA o 0 - 10 V Kit BSR retorno por bateria Potenciometro digital: 1K, 5K y 10K 3 posiciones: 0º - 45º - 90º / 0º - 90º - 180º ALL MODELS OPTIONS: DPS2005 digital positioner kit: 0-20 mA, 4 -20 mA or 0 -10 V BSR battery fail safe kit Digital potentiometer: 1K, 5K and 10K 3 positions stop: 0º - 45º - 90º / 0º - 90º - 180º Solo J3C 20 y J3C 35 Kit conversión de F05 a F07 doble cuadrado 17 mm J3C 20 & J3C 35 only Conversion kit from F05 to F07 double square 17 mm Kit BSR retorno por bateria BSR battery fail safe kit 3 Kg 3 Kg Kit posicionador digital DPS2005: 0 ÷ 20 mA, 4 ÷ 20 mA o 0 ÷10 V DPS2005 digital positioner: 0 ÷ 20 mA, 4 ÷ 20 mA o 0 ÷ 10 V OPEN CLOSE A = Power supply plug / Alimentación eléctrica VAC 3 WIRES (Grey plug) VAC 3 CABLES (Conector gris) PIN 1 = Neutral + PIN 2 = Phase = Close / Cierra OPEN PIN 1 = Neutral 2 1 = Open / Abre manual override mando manual de emergencia position indicator indicador posición PIN 1 / PIN 3 = Open / Abierto 3 A -_ PIN 3 = Phase PIN 1 / PIN 2 = Close / Cerrado 3 196 7.72" + B = Volt free contacts plug / Contactos auxiliares 2 1 17.6 0.69" J3C 20 & J3C 35: ISO5211 Mutiflange standard F03/F04/F05 J3C 55 & J3C 85: ISO5211 Multiflange standard F05/F07 ABRE - CIERRA CLOSE 196 7.72" Housing (Body and Cover): Anticorrosive Polyamide Main external shaft: Stainless Steel Fastening : Stainless Steel Gears: Steel and Polyamide Indicator: Polyamide + Glass filled Internal cams: Polyamide + Glass filled Electric motor: Single phase Insulation: Class B Service S4 Duty range: 75% EXTERNAL ELECTRIC WIRING / ESQUEMA EXTERNO DE CONEXIONES J3C L/H-85 171 6.73" Envolvente (Cuerpo y tapa): Poliamida anticorrosiva Ejes principales: Acero inox Tornillería exterior: Acero inox Engranajes: Acero y Poliamida Indicador visual posición Poliamida+ fibra vidrio Levas internas: Poliamida + fibra vidrio Motor Monofásico: 24 VDC Aislamiento B Servicio S4 Tiempo bajo tensión 75% B A = Power supply plug / Alimentación eléctrica + VDC CLOSE OPEN OPEN CLOSE VAC 3 WIRES (Grey plug) VAC 3 CABLES (Conector gris) PIN 1 = Neutral + PIN 2 = Phase = Close / Cierra PIN 1 = Neutral + PIN 3 = Phase power supply plug alimentación eléctrica visual control of operation control visual operación = Open / Abre 16/19 177 6.97" 16/19 55 2.16" 55 2.16" 51 2,01" 126 4.96" 177 6.97" 42 126 4.96" 6.97" 55 2.16" 177 6.97" 55 2.16" 9x9 11 x 11 14 x 14 55 2.16" 42 3 A PIN 1 / PIN 2 = Close / Cerrado PIN 1 / PIN 3 = Open / Abierto 3 B EXTERNAL ELECTRIC WIRING / ESQUEMA EXTERNO DE CONEXIONES POSITIONER POSICIONADOR N or _ L or + 4xM8 110 4.34" 11/14/17 4xM6 14/17 3 2 50 1 50 A: VAC 2 WIRES (Grey plug) / VAC 2 CABLES (Conector gris) OUTPUT A 3 INPUT B Signal instrumentation NO VOLTAGE 1 - B = Signal instrumentation / Señal de instrumentación Output signal : 4/20mA or 0/10V / Señal de salida: 4/20mA or 0/10V PIN 1 = (-)Negative + PIN 2 = (+) Positive = Input signal / señal de entrada 2 1 C 3 volt free contacs plug contactos auxiliares PIN 1 = Neutral or (-) + PIN 2 or (+) = Power supply plug / Alimentación eléctrica B: Input signal : 4/20mA or 0/10V / Señal de entrada: 4/20mA or 0/10V 4xM6 70 OPEN CLOSE 2 50 B = Volt free contacts plug / Contactos auxiliares 2 1 36 110 4.34" 2 1 55 2.16" A = Power supply plug / Alimentación eléctrica 4xM8 110 4.34" 51 2,01" 70 51 2.01" 126 4.96" PIN 1 = (-)Negative + PIN 3 = (+) Positive = Output signal / señal de salida C = Volt free contacts plug / Contactos Auxiliares C: PIN 1 / PIN 2 = Closed / Cerrado PIN 1 / PIN 3 = Open / Abierto automatic/manual lever palanca automático-manual ISO multiflange multibrida ISO Cardedeu, May the 8th 2013 We hereby declare that all electric actuators we manufacture with J+J trademark, and named: J3C H20, J3CL20, J3H35, J3L35, J3H55, J3L55, J3H85, J3L85, J2H140, J2L140, J2H300, J2L300, J2H10, J2L10 Are manufactured 100% in Spain (European Community CE) with the highest care and best materials.Besides, they are tested individually following strict standards, in order to guarantee constant quality as time passes. Technical features and conditions of use of our actuators are described in J+J Instruction manual for installation, use and maintenance and in the corresponding catalogue of each Series of actuators. Furthermore, we underline that the reliability of a.m. products is regularly verified on every unit we made; the results of such tests guarantee the duration of actuators in working phase, under stated conditions, for ten thousand (10.000) cycles (ten thousand opening movements and ten thousand closing movements). J.J. BCN INTERNACIONAL S.A. ENRIC GRÀCIA J.J. BCN INTERNACIONAL, S.A. Poligono Industrial Sud C/.De l´Orfeó Català, 7 E – 08440 Cardedeu (Barcelona) 0034938713304 0034938713272 Original Declaration of Incorporation of Partly Completed Machinery (EC Directive 2006/42/EC) and EC Declaration of Conformity in compliance with the Directives on EMC and Low Voltage For electric actuators of the series J3 / J3C type ranges: L20, L35, L55, L85, H20, H35, H55, H85 in versions: Standard, DPS, BSR, DPS + BSR, Poti J.J. BCN INTERNATIONAL S.A. as manufacturer declares herewith, that the above mentioned partturn actuator meet the following basic requirements of the EC Machinery Directive 2006/42/EC: Annex I. articles 1.1.2, 1.1.3, 1.1.5, 1.2.1, 1.2.6, 1.3.1, 1.3.7, 1.5.1, 1.6.3, 1.7.1, 1.7.3, 1.7.4 The following harmonised standards within the meaning of the Machinary Directive have been applied: EN 12100-1:2003 ISO 5211:2001 EN12100-2: 2003 EN 60204:2006 With regard to the partly completed machinery, the manufacturer commits to submitting the documents to the competent national authority via electronic transmission upon request. The relevant technical documentation pertaining to the machinery described in Annex VII, part B has been prepared. J+J part turn actuators are designed to be installed on industrial valves. J+J part turn actuators must not be put into service until the final machinery into which they are to be incorporated has been declared in conformity with the provisions of the EC Directive 2006/42/EC. Authorised person for documentation: Name: David Marcús Manzanares Address: C/.De l´Orfeó Català, 7 , E – 08440 Cardedeu (Barcelona) As partly completed machinery, the part turn actuators further comply with the requirements of the following directives and the respective approximation of national laws as wee as the respective harmonised standards as listed below: (1) Directive relating to Electromagnetic Compability (EMC) (2004/108/EC) EN 61000-6-4: 2007 EN 61000-6-2: 2005 EN 61800-3: 2004 (2) Low Voltage Directive (2006/95/EC) EN 60204-1: 2006 EN 60034-1: 2004 EN 50178: 1997 EN 61010-1: 2001 Year of affixing of the CE marking: 2008 Cardedeu 2012-11-09 J. Chaves Technical Manager This declaration does not contain any guarantees. The safety instructions in product documentation supplied with the devices must be observed. Non concerted of the devices voids this declaration. TEST REPORT Report number: 10/31702431M1”English translation from the original in Spanish”Date15-11-2010 Page 1 of 11 Customer’s reference J.J. BCN INTERNACIONAL S.A. c/ de l’Orfeò Català, 7 Pol. Ind. Sud. 9 / LE / 894 08440 Cardedeu (Barcelona) The product* 1 electric rotary actuator, brand J+J, models J3C H-20 with internal reference number 20100386, Has been tested and found in conformity with the applied specifications of the standard/s UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) With the following IP protection degree: IP 67 * See page 3 for list of extended models Description of modification 1: Designation of models corrected. This report substitutes and annuls the report 10/31702431 issued on 10-11-2010 José Luis Medina Abellán Project Manager Electrical & Electronics Center LGAI Technological Center, S.A. Only the tests reports with original signatures or its attested copies have legal validity. The reproduction of this document, is only authorised if it’s made in its totality. The document has 11 pages from which 2 are appendix. In case of discrepancy the Spanish version prevails. The results reported in this document relate only to the sample, product or item submitted to the Laboratory and described above, having been tested under the conditions established in this document. UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: 10/31702431M1”English translation from the original in Spanish” Page 2 of 11 UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) “DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE)” Test Report Nº................................. : 10/31702431M1”English translation from the original in Spanish” Date of receipt of test item ............... : 04/11/2010 Date of performance of test (start) ... : 05/11/2010 Date of performance of test (end) ... : 10/11/2010 Applicant’s Name ............................. : J.J. BCN INTERNACIONAL S.A. Address ........................................... : c/ de l’Orfeò Català, 7 Pol. Ind. Sud. 08440 Cardedeu (Barcelona) Applicant’s Name ............................ :LGAI APPLUS Technological + LGAI Center, S.A. Address ..........................................: Campus de la UAB Aptdo. Correos 18 08193 Bellaterra (Barcelona – España) Test item description ....................... : Electric rotary actuators Manufacturer .................................. : J.J. BCN INTERNACIONAL S.A. Brand ............................................. : J+J Model ............................................. : J3C H-20 Serial number .................................. : --Internal identification number ........... : 20100386 Environmental conditions during the tests Temperature (ºC) ............................ : 23,8 Relative Humidity (%) ...................... : 51 UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: 10/31702431M1”English translation from the original in Spanish” Page 3 of 11 Information / comments: List of extended models from tested models: J2 L-10, J2 H-10, J3C L-20, J3C H-20; J3C L-35, J3C H-35, J3C L-55, J3C H-55, J3C L-85, J3C H-85 Differences with the tested models. Models with H are for supply voltage of 85-240 V DC or AC 50/60 Hz. Models with L are for supply voltage of 12-24 DC or AC 50/60 Hz. The sealing devices and the external cover and dimensions for models with H or L with the same number are identical. Uncertainty of measurement The reported uncertainty is an expanded uncertainty calculated using a coverage factor k of 2 which gives a level of confidence of approximately 95 %. The typical uncertainty of measurement has been determined according to E4-02. Temperature = ± 1 ºC Current = ± 1,5 % Voltage = ± 0,7 % Power = ± 1 % Resistance = ± 2 % Dimensions = ± 0,06 mm Possible test case verdicts - Test case does not apply to the test object ..............: N(ot)A(pply) - Test object does meet the requirement ...................: P(ass) - Test object does not meet the requirement ..............: F(ail) - Test object does not evaluated ................................: N(ot)T(ested) - Observation about test object ..................................: OBS(ervation) General remarks Throughout this report a point is used as the decimal separator. The test results presented in this report relate only to the object tested. This report shall not be reproduced except in full without the written approval of the testing laboratory. Service Quality Assurance Applus+, guarantees that this work has been made in accordance with our Quality and Sustainability System, fulfilling the contractual conditions and legal norms. Within our improvement program we would be grateful if you would send us any commentary that you consider opportune, to the person in charge who signs this document, or to the Quality Manager of Applus+, in the following e-mail address: satisfaccion.cliente@appluscorp.com UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: Clause 10/31702431M1”English translation from the original in Spanish” Requirement - Test Page 4 of 11 Result - Remark Verdict 5 DEGREE OF PROTECTION, AGAINST ACCESS TO HAZARDOUS PARTS AND AGAINTS SOLID FOREIGN OBJECTS INDICATED BY THE FIRST CHARACTERISTIC NUMERAL 5.1 Protection against access to hazardous parts P First characteristic numeral: 5.2 7 8 9 P Test conditions according to sub-clause 12.2 P Compliance checked P Protection against solid foreign objects P First characteristic numeral: 6 IP6X IP6X P Test conditions according to sub-clause 13.2 or 13.4 or 13.5 P Compliance checked P DEGREES OF PROTECTION AGAINST INGRESS OF WATER INDICATED BY THE SECOND CHARANTERISTIC NUMERAL Second characteristic numeral: P IPX7 Test conditions according to sub-clause 14.2.1 to 14.2.8 as applicable P Compliance checked P DEGREES OF PROTECTIONAGAINST ACCESS TO HAZARDOUS PARTS INDICATED BY THE ADDITIONAL LETTER Additional letter NA Test conditions according to sub-clause 15.2 NA Compliance checked NA SUPPLEMENTARY LETTERS Additional supplementary letter: NA Test conditions according to sub-clause 15.2 NA Compliance checked NA IP CODE DESIGNATIONS UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: Clause 10/31702431M1”English translation from the original in Spanish” Requirement - Test Page 5 of 11 Result - Remark Verdict MARKING Specified in relevant product standards NA Such standard also specify the method of marking which is to be used when NA - one part of an enclosure has a different degree of protection to that of another part of the same enclosure NA - the mounting position has an influence on the degree of protection NA - the maximum immersion depth and time are indicated NA 11 GENERAL REQUERIMENTS FOR TESTS 11.1 Atmospheric conditions for water or dust tests P - temperature P - relative humidity P - air pressure P Test samples P 10 11.2 - number of samples tested 1 by model P - conditions for mounting assembling and positioning of the samples Samples in normal use position P - pre-conditioning, if any Without pre- conditioning P - tested energized or not Not energized P - tested in motion or not No in motion P The manufacturer’s instructions shall apply in the absence, of such specifications 11.3 Application of test requirements and interpretation of test results - responsibility of the relevant technical committee 11.4 11.5 NA P NA - in the absence of such specification the requirement of this standard shall apply P Combination of test conditions for the first characteristic numeral P First characteristic numeral: P Empty enclosures: NA UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: Clause 10/31702431M1”English translation from the original in Spanish” Requirement - Test Page 6 of 11 Result - Remark Verdict Detailed requirements shall be indicated by the enclosure manufacturer in his instructions for the arrangement and spacing of hazardous parts or parts which might be affected by the penetration of foreign objects or water NA The manufacturer of the final assembly shall ensure that after the electrical equipment is enclosed the enclosure meets the declared degree of protection of the final product. NA 12 TEST OF PROTECTION AGAINST ACCESS TO HAZARDOUS PARTS INDICATED BY THE FIRST CHARACTERISTIC NUMERAL 12.1 Access probes according to Table VI are used P 12.2 Test conditions as specified P 12.3 Acceptance conditions P Adequate clearance is kept between access probe and hazardous parts P 12.3.1 12.3.2 12.3.3 For low-voltage equipment NA The access probe shall not touch hazardous live parts NA For high-voltage equipment NA The equipment shall be capable of withstanding the dielectric tests as specified in the relevant product standard applicable to the equipment NA Where an enclosure includes sections at different voltage levels the appropiate acceptance conditions for adequate clearance shall be applied for each section NA For equipment with hazardous mechanical parts P The access probe shall not touch hazardous mechanical parts P 13 TEST FOR PROTECTION AGAINST SOLID FOREING OBJECTS INDICATED BY THE FIRST CHARACTERISTIC NUMERAL 13.1 Test means and the main test conditions according to Table VII are used P 13.2 Test conditions for first characteristic numerals 1,2,3,4 NA UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: Clause 13.3 10/31702431M1”English translation from the original in Spanish” Requirement - Test Result - Remark Page 7 of 11 Verdict Object probe is pushed against any openings of the enclosure with the force specified in table VII NA Acceptance conditions for first characteristic numerals 1,2,3,4. NA The protection is satisfactory if the full diameter of the probe does not pass through any opening NA Dust test for first characteristic numerals 5 & 6 P P 13.5.1 Tests are conducted as specified and classified Category 1 according to its category 1 or 2 If it is impractical to test the complete enclosure in the test chamber, one of the following procedures shall be applied: - testing of individually enclosed sections of the enclosure - testing of representative parts of the enclosure, comprising components such as doors, ventilation openings, joints, shaft seals, etc., in position during test - testing of a smaller enclosure having the same full-scale design details Special conditions for first characteristic numeral 5 Test conditions as specified 13.5.2 Acceptance conditions NA NA 13.6.1 The protection is satisfactory if talcum powder has not accumulated in quantity or location such that, as with any other kind of dust, it could interfere with the correct operation of the equipment or impair safety No dust shall deposit where it could lead to tracking along the creepage distances. Special conditions for first characteristic numeral 6 Test conditions as specified 13.6.2 Acceptance conditions P The protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test. P 13.4 13.5 13.6 NA NA NA NA NA NA NA P P UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: Clause 10/31702431M1”English translation from the original in Spanish” Requirement - Test Result - Remark Page 8 of 11 Verdict 14 TESTS FOR PROTECTION AGAINST WATER INDICATED BY THE SECOND CHARACTERISTIC NUMERAL 14.1 14.2 Test means and test conditions are performed according to table VIII P 14.2.1 14.2.2 14.2.3 14.2.4 14.2.5 14.2.6 14.2.7 14.2.8 14.3 Test for second characteristic numeral 1 with drip box Test for second characteristic numeral 2 with drip box Test for second characteristic numeral 3 with oscillating tube or spray nozzle Test for second characteristic numeral 4 with oscillating tube or spray nozzle Test for second characteristic numeral 5 with the 6,3 mm nozzle Test for second characteristic numeral 6 with the 12,5 mm nozzle Test for second characteristic numeral 7, temporary immersion between 0,15 m and 1 m Test for second characteristic numeral 8: continuous immersion subject to agreement. Acceptance conditions NA It is the responsibility of the relevant Technical committee to specify the amount of water which may be allowed to enter the enclosure and the details of a dielectric strength test, if any In general, if any water has entered, it shall not P - be sufficient to interfere with the correct operation of the equipment or impair safety - deposit on insulation parts where it could lead to tracking along the creepage distances - reach live parts or windings not designed to operate when wet - accumulate near the cable end or enter the cable if any For enclosure with drain-holes, it should be proved By inspection that any water which enters does not accumulate and that it drains away without doing any harm to the equipment For enclosures without drain-holes; the relevant product standard shall specify the acceptance conditions if water can accumulate to reach live parts P NA NA NA NA NA P NA P P P P P NA NA NA UNE 20324:1993 + 1M: 2000 + ERR: 2004 (EN 60529:1991 + ERR: 1993 + A1:2000) Report nº.: Clause 10/31702431M1”English translation from the original in Spanish” Requirement - Test Page 9 of 11 Result - Remark Verdict 15 TESTS FOR PROTECTION AGAINST ACCESS TO HAZARDOUS PARTS INDICATED BY THE ADDITIONAL LETTER 15.1 NA 15.2 Access probes to hazardous parts according to table VI Test conditions as specified 15.3 Acceptance conditions NA The protection is satisfactory if adequate clearance is kept between the access probe and hazardous parts NA NA ANNEX 1: PHOTOGRAPHS Report nº.: 10/31702431M1”English translation from the original in Spanish” PHOTOGRAPHS. View of tested sample. View of tested sample. Page 10 of 11 ANNEX 1: PHOTOGRAPHS Report nº.: 10/31702431M1”English translation from the original in Spanish” View of tested sample. Page 11 of 11