MODEL 353SOBK Page 1 GABLE-MOUNT SOLAR POWERED ATTIC VENTILATOR READ AND SAVE THESE INSTRUCTIONS WARNING CAUTION TO REDUCETHE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Usethisunitonlyinthemannerintendedbythemanufacturer. Ifyouhavequestions,contactthemanufacturerattheaddress ortelephonenumberlistedinthewarranty. 2. Beforeservicingorcleaningunit,disabletheventilatorbycoveringthesolarpanelwithcardboardordisconnectingthewires fromthemotorterminals(notewirelocationswhendisconnecting). 3. Installationworkmustbedonebyaqualifiedperson(s)inaccordance with all applicable codes and standards, including fire-ratedconstructioncodesandstandards. 4. Ifremovinganexisting120VACpoweredatticventilator,use only a qualified person(s) to remove any electrical wiring in accordancewithallapplicablecodesandstandards. 5. Sufficientairisneededforpropercombustionandexhausting ofgasesthroughtheflue(chimney)offuelburningequipment topreventbackdrafting.Followtheheatingequipmentmanufacturer'sguidelinesandsafetystandardssuchasthosepublished by the National Fire ProtectionAssociation (NFPA), and the AmericanSocietyforHeating,RefrigerationandAirConditioningEngineers(ASHRAE),andthelocalcodeauthorities. 6. When cutting or drilling into wall or ceiling, do not damage electricalwiringandotherhiddenutilities. 1. Forgeneralventilatinguseonly.Donotusetoexhausthazardousorexplosivematerialsandvapors. 2. Toavoidmotorbearingdamageandnoisyand/orunbalanced impellers,keepdrywallspray,constructiondust,etc.offpower unit. 3. Thisunithasanunguardedimpeller.Donotuseinlocations readilyaccessibletopeopleoranimals. 4. This ventilator operates when the solar panel is exposed to sunlight.Toreduceriskofinjurywhileinstalling,servicingor cleaningunit,coverthesolarpanelwithcardboardordisconnectthewiresfromthemotorterminals(notewirelocations whendisconnecting). 5. The recommended open air inlet for this ventilator is 4.25 square feet.The best location for these air intake vents are undertheeaveswithdirectaccesstotheattic.Failuretoprovidetheseintakescouldcausenatural-draftgasappliancesto backdraft. 6. Youratticfaninstallationwillcreateascreenedopeninginto youratticspace.Duringaheavyrainstormtherecouldbea lightsprayofrainintothisatticspace.Thisisanormalconditionwithallatticventilatorsandwillnotcauseanydamageto thestructure.Werecommendthatyoudonotstoreanyvaluablearticlesdirectlyunderthefanopeningintheroof. 7. This ventilator is intended for gable (side wall) installation. Broan Models 349, 350, 355, & 356 Roof MountVentilators areavailableforroofapplications. 8. ThisventilatorissuitableforusewithBroanModel433AutomaticShutter(purchaseseparately). 9. The plastic ventilator dome and base may be painted with highqualitypaint.Followthepaintmanufacturer'srecommendationsforacrylicandABSplasticasappropriate.Takecare toavoidgettingpaintonthesolarpanel. 10.Pleasereadspecificationlabelonproductforfurtherinformationandrequirements. 11. The installation instructions contained in this document are only a recommendation and individual professionals may havetheirownmethodsofinstallation. TOOLS AND MATERIALS REQUIRED SlottedScrewdriver r Drill r 1/4"DrillBit r SabreSaworKeyholeSaw r Saw r Hammer r Ruler/TapeMeasure r Pencil,MarkerorScribe r UtilityKnife r SiliconeorRoofingCement r GalvanizedRoofingNails(1¾"min.) r Register your product online at: www.broan.com/register MODEL 353SOBK Page 2 VENTILATOR INSTALLATION 19-1/4” Note: This ventilator is capable of replacing an existing 120 volt powered attic ventilator. Only a qualified person should remove any electrical wiring in accordance with local codes and standards. 16-1/8” 2” MIN. 1. The ventilator is designed to mount behind existing louvers. Louvers should be mounted in the center of thegableashighaspossible.Formaximumefficiency, theopenareaofthelouvershouldbegreaterthanthe outletareaoftheventilator.Ifnolouverexists,onemust beinstalled.Followthemanufacture’srecommendation forinstallingthelouver. CAUTION! When installing louvers or ventilator, do not remove any existing structural members without providing alternate support members. 2. Locatetheremotesolarpanelonyourroofwherethe sun’s exposure is best barring shade (trees, other buildingsetc)at4:00pminthehottestmonthoftheyear. Thesolarpanelcomesfromthefactorywith15feetof wire.Ifthedesiredlocationofthesolarpanelisgreater than15feetawayfromtheventilator,anadditional50 ftof14AWG(minimum)ULlistedorrecognizedcopper wiremaybeused. 3. Prior to installation, we recommend setting up the ventilator and solar panel to verify operation. Take the fan and solar panel to a location exposed to sun. Connecttheredsolarpanelwiretotheblack(negative) motor terminal and the black solar panel wire to the red(positive)motorterminal.Removingthecardboard coverfromthesolarpanelshouldcausetheventilatorto operate.Placecardboardoversolarpanel(forsafety), disconnect wire from motor terminals and proceed to installationinstructionsoutlinedbelow 4. Theventilatorcanbeinstalledbetweenstudsorplaced overacurbmanufacturedfrom2”x4”or2”x6”wood (refer to illustration above for curb dimensions). Nail orscrewtheventilatortothewallstudsorcurbaround perimeterofbaseevery6inches. 5. Makesuretheoutletoftheventilatorisproperlysealedto theexteriorwalltomaximizetheamountofairexhausted bytheventilator.Wheninstallingtheventilatorbehind louvers, seal off any louver area not covered by the ventilatorbase topreventairleakageandrecirculation. MODEL 353SOBK Page 3 REMOTE SOLAR PANEL INSTALLATION SERVICE PARTS 1 2 3 4 6. Working from inside the attic, find the center of the selectedsolarpanellocationidentifiedinstep2,drilla smallholeintheroofdeckinglargeenoughforthesolar panelwiretofitthrough. 7. Feedthesolarpanelwirethroughtheholeintotheattic. 8. Run a bead of silicone or roof cement around the perimeteroftheundersideofthesolarpanelandsecure totheroofusingnailsorscrews.Nailorscrewallcorners andperimeterofbaseevery6inches.Sealthefastener headswithsiliconeorroofcement. 9. From inside the attic, apply silicone around the wire whereitenterstheroof. Replacement parts can now be ordered on our website. Please visit us at www.Broan.com 10.Connecttheredwiretothepositivemotorterminaland theblackwiretothenegativemotorterminal.Tapeor tieextrawiretopreventcontactwiththefanblade. 11. Removecardboardfromthesolarpanelandverifythat theventilatoroperates. Key No. Model 355RSOBK (Black) Description 1 2 3 4 S99527255 S99527261 S99527257 S99527250 SolarPanelAssembly FanBladew/SetScrew Motor,DC RoofSheetPanel MODEL 353SOBK Page 4 WARRANTY BROAN-NUTONE LLC – Exclusive Limited Warranty – The Exclusive Limited Warranty Agreement (the “Warranty”) is entered into by and between Customer and Broan-NuTone LLC (“Broan”). Customer has carefully reviewed thisWarranty and agrees that Broan’s performance of its obligations hereunder will provideCustomerwithanadequateremedywhichwillservetheessentialpurposeoftheparties’agreementrelatingtotheproducts manufacturedbyBroanandidentifiedonthereversesidehereof(the“Products”).Customeracknowledgesandagreesthathe/sheis purchasingtheProductsforresidentialpurposes(andnotforindustrialorcommercialpurposes)aftercarefulinspectionofthesame. Customer’srightsandbenefitshereunderinuresolelytoCustomer,astheoriginalpurchaseroftheProducts,andarenon-assignable andnon-transferable.Nootherpartyorentity,including,withoutlimitation,subsequentpurchasersorownersoftheProductsshall haveorbeentitledtoassertanyrightsorbenefitshereunder. EXCLUSIVELIMITEDWARRANTY;LIMITATIONOFREMEDIES.BroanherebywarrantstheCustomerthattheProducts’motors areandwillremainforaperiodoftwo(2)yearsfromthedateofdeliverytoCustomer;andtheProductsareandwillremainfora periodofsix(6)yearsfromthedateofdeliverytoCustomer(collectively,the“WarrantyPeriod”),freeofdefectsinmaterialsand workmanship,providedthatsuchProductsareusedfortheirintendedpurposeandareproperlyservicedinaccordancewiththe User’sManualprovidedtoCustomer.Subjecttotheforegoing,ifatanytimeduringtheWarrantyPeriodanyProductfailstoconform totheforegoingwarrantybyreasonofdefectsinmaterialsorworkmanship,CustomershallproperlynotifyBroaninwritingandshall includewithsuchnoticeasalesreceiptorproofofpurchaseofthedefectiveProduct,andBroanatitsoptionshallrepairorreplace thedefectiveProductorcomponentpartwithoutchargetoCustomer,exceptfor:(A)costsincurredintransportingtheProductsor componentpartstoandfromBroan’sdesignateddealeroritsmanufacturingplantinHartford,Wisconsin;and(B)chargesforlabor orothercostsincidentaltotheremovalorremountingofcomponentpartsrepairedorreplacedunderthisWarranty,bothofwhich shallbebornebyCustomer.Notwithstandinganyprovisionhereintothecontrary,thisWarrantyshallnotextendorobligateBroan totakeanyactionwithrespectto:(A)Productswhichhavebeenmodified,altered,installed,usedoroperatedinamannerwhichis notrecommendedbyBroan,includinganyProductsinwhichpartsnotmanufacturedorapprovedbyBroanhavebeeninstalled;(B) ProductswhichhavenotbeenregularlyorproperlyservicedinaccordancewiththeUser’sManualorwhichhaveotherwisebeen neglected;and(C)ordinarywearandtear,serviceandmaintenanceandreplacementitems.THISWARRANTYAPPLIESONLY TOMACHINERY,EQUIPMENTANDCOMPONENTPARTSMANUFACTUREDBYBROAN.THISWARRANTYDOESNOTAPPLY OR EXTENDTO:(A)PARTSPURCHASEDSEPARATELYFROMSUCHMACHINERYANDEQUIPMENT,WHICHARECOVERED BYASEPARATEWRITTENWARRANTY;OR(B)ITEMSOFEQUIPMENTORACCESSORIESMANUFACTUREDBYPARTIES OTHERTHANBROAN. EXCEPT AS SPECIFICALLY STATED IN THE PARAGRAPH IMMEDIATELY ABOVE, BROAN MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE WARRANTY SET FORTH IN THE PRECEDING PARAGRAPH AND THE OBLIGATIONS AND LIABILITIES OF BROAN THEREUNDER REPRESENT CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES AND ARE EXPRESSLY MADE IN LIEU OF ANY AND ALL OTHER REMEDIES, WARRANTIES, GUARANTIES OR LIABILITIES, EXPRESS OR IMPLIED, ALL OF WHICH ARE HEREBY EXPRESSLY WAIVED BY CUSTOMER. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT SHALL BROAN’S LIABILITY HEREUNDER EXCEED THE PURCHASE PRICE FOR THE PRODUCTS. ADDITIONALLY, BROAN SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER. Broanreservestherighttomodify,alterorimproveanyproductsorequipmentmanufacturedbyBroanwithout incurringanydutyor obligationtomodify,alter,improveorreplaceanyoftheProductscoveredhereby. THIS WARRANTY SETS FORTH THE PARTIES’ FINAL, COMPLETE AND EXCLUSIVE AGREEMENT CONCERNING THE PRODUCTS AND BROAN’S WARRANTY OBLIGATIONS. NO AFFIRMATION OF FACT, PROMISE, DESCRIPTION, DEMONSTRATION, SAMPLE OR MODEL CONSTITUTES A WARRANTY OR OTHERWISE MODIFIES, EXTENDS OR ALTERS THIS WARRANTY UNLESS IN A WRITTEN INSTRUMENT SIGNED BY AN AUTHORIZED BROAN OFFICER. ThisWarrantyshallbegovernedbyandconstruedinaccordancewiththelawsoftheStateofWisconsin.Thevenueforanyaction arisingoutoforrelatedtothisWarrantyshallbeinWashingtonCounty,Wisconsin. 99527271B