QUICKSTART “BASIC” HARDWIRE TRACKER EXPANSION BOARD TO RELAY 2/WIEGAND 2 GUIDELINES For COMPLETE installation instructions, please refer to the HARDwired Installation/Owner’s manual P/N 2358-065. Tracker Expansion Board Enclosure Options Access Control System Board RS 232 Single Board Enclosure with Built-In Card Reader and Lighting DK Prox Reader - P/N 1815-333 HID Reader - P/N 1815-392 AWID Reader - P/N 1815-292 Single Board Enclosure P/N 2351-080 120 Glasgow Avenue Inglewood, California 90301 Quad Board Enclosure P/N 2351-081 U.S.A. ELEVATOR 1 2 Tracker Expansion Board Notes: 3 7 8 9 10 2C 2RY 15 16 1C 1NC 1NO BAT 16AC 16AC 17 18 19 20 NO Relay 1 BOARD ADDRESS 1 0 ON 4 5 6 RF SECURE RF RF DATA STATUS CODE CODE CODE SENT GOOD BAD 7 8 OUTPUT RELAY NC NO ALARM RELAY NC NO AUX RELAY NC NO 2358-010 RESET Ground 12 GA. Wire ENT Tracker Expansion Board Address 3 Board Power 16.5 VAC, 20 VA Required 18 GA. Wire 100 ft max 16 GA. Wire 200 ft max BOARD ADDRESS 1 Gate Operator Control UT TP OU LAY RE NC Relay Jumper 0 To #8 Red #10 Blue #17 To #18 Brown #19 SH PU TO ON RF SECURE RF RF DATA STATUS CODE CODE CODE SENT GOOD BAD 7 8 OUTPUT RELAY NC NO ALARM RELAY NC NO AUX RELAY NC NO 2358-010 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 RESET NO Lock Power Electric Strike Door Lock Ground #32 Ground ENT Tracker Expansion Board Address 4 IT EX Request to Exit (Free Exit) Green #29-Data 1 White #28-Data 0 Black #27-Com #20-Card Reader LED OR Beeper Control (Available on certain card readers) OR NO Ground #32 Card Reader N Output Relay #25 & #26 UT TP OU LAY RE NC Black #27-Com White #28-Data 1 Green #29-Data 0 21 22 23 24 25 26 27 28 29 30 31 32 33 34 0 OFF Relay Jumper Board Address 10 Setting 7 8 Power #33 Power #34 1 2 6 conductor, stranded with overall 3 shield, 18-22 gauge. 500 ft max. 4 DO NOT use twisted pair. 5 #6-Green = Data 0 6 #7-White = Data 1 7 #8-Black = Common 8 #9-Red = 12 VDC Power 9 10 #10 connects 11 ONLY to tracker 12 expansion boards 13 14 15 16 17 18 19 20 NCO Black #27-Com White #28-Data 1 Green #29-Data 0 Com Brown #19 26, 30, 31-Bit Wiegand Power for electric strike or magnetic lock is NOT provided by the board. Use separate UL listed power supply. Power #33 Power #34 N.O. Blue #17 Wiegand Access Control Device Blue - Beeper Relay 2 Set Output Relay Jumper UT TP OU AY Maglock REL 1 ON 90 1 Relay 2 Jumper Main Power 0 OFF Black #27-Com White #28-Data 1 Green #29-Data 0 NC Note: If card reader has additional lighting for outdoor use, separate power must be provided. Switch MUST be OFF (0) for board addresses 3 thru 9. NO 4 5 6 9 10 11 12 13 14 6 7 8 Relay 2 Jumper 13 14 OR Yellow - LED Important Note: Relay 2 is used to control tracker expansion board addresses 3-10, Relay 1 or Relay 0 can be used as the Primary Relay that will open a visitor door or gate when the resident pushes “9” on their telephone. A 90 1 Main Door/Gate Relay 1 or Relay 0 12 Z Blue #14 Switch closure across terminals 4 & 6 will activate relay 1 for its programmed strike time. (Postal Lock) 11 0 OFF BOARD ADDRESS Relay Jumper 4 5 6 6 Electric strike UT TP OU LAY E R NC 4 56 5 4 56 4 Brown #13 Central Office phone line touch tone, loop start. 3 CGND PSW MIC COM SPKR IMD 5VDC IMC 7 8 Red #10 2 PHONE DK Prox Reader Aux Power 1 ON Second Board Address Set to 4 9 0 1 1 NC Switch MUST be ON (1) for board address 10. 2 3 RING NO C Card Reader 1 Door Lock Control BOARD ADDRESS 9 0 1 NO NC First Board Address Starts at 3 9 0 1 Relay 0 ON MASTER CODE OFF KEYPAD 1 2 3 4 5 Auxiliary Terminal CLK SEN Board addresses MUST start at 3 and contiunue thru board address 10 (up to BOARD ADDRESS 12 boards using Zone ON Addresses) if required. 7 8 2 3 3 2 1 Communication line will continue for each board like shown on tracker expansion board address 4. Tracker expansion boards connected to Wiegand 2 will activate Relay 2 in the access control system. 2 3 3 2 1 FEED BACK Communication 2 Black #9-Com White #8-Data 1 Green #7-Data 0 2 3 3 2 1 SPK VOL Auxiliary Terminal 2 3 MIC VOL All tracker expansion boards can be wired with desired options for their access points like shown on tracker expansion board address 3. Board Power To #18 To #8 Com SH PU TO IT EX Request to Exit (Free Exit) Tracker Expansion Board “Busy” #10 Typical BASIC Tracker Expansion Board Wiring Options for Access Point NO “optional” tracker features or battery back-up wiring shown, see manual for details. Use 6 conductor stranded with overall shield. 18 - 22 gauge. ONLY use 18 gauge when wiring more than 8 boards. DO NOT connect shield to 2358-010 board common. DO NOT use twisted pair. To Board Addresses 5 thru 10 Communication Line Up to 12 tracker expansion boards can be HARDwired to relay 2/wiegand 2 at the access control system. IMPORTANT: The maximum distance for a tracker expansion board HARDwire run is 4000 feet TOTAL (1 to 12 boards can be in a HARDwire run). The farthest board can be NO more than 2000 feet away from the access control system. See manual for multiple tracker expansion boards layout limitations. QUICKSTART PROGRAMMING OPTIONS ON EACH HARDWIRED TRACKER EXPANSION BOARD GUIDELINES For COMPLETE programming instructions, please refer to the HARDwired Installation/Owner’s manual P/N 2358-065. BOARD ADDRESS Relay Communication Line (NO) Request to Exit Relay Communication Line (Com) Card Reader LED/Beeper Control ON CODE CODE CODE SENT GOOD BAD 7 8 4 5 6 0 OUTPUT RELAY NC NO ALARM RELAY NC NO AUX RELAY NC NO 2358-010 Relay jumpers MUST be set for each relay used. 2 3 Data 0 Data 1 Access Control Device 26, 30, 31-Bit Wiegand Com 12 VDC Tracker Expansion Board Busy 1 RF RF DATA STATUS 90 1 Board addresses MUST be set for each board used. RF SECURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Programming Options on EACH Tracker Expansion Board Program Step Aux Relay Description Selection Options Number 1 Door Strike Timer 00 - 99 00 01 - 99 2 Free Exit Timer, Strike Time 00 - 99 00 01 - 99 3 Door Ajar Timer 00 - 99 00 01 - 99 4 Aux Relay Timer 00 - 99 00 01 - 99 5 Free Exit Timer, Aux Relay 00 - 99 00 01 - 99 6 Free Exit, No Strike 0 or 1 0 1 7 Not Used 8 Door Contact Switch Logic 0 or 1 9 Auto Relock 0 or 1 10 Beeper / LED Hold Open 0 or 1 11 Hold Open or Hold Egress functions 0 or 1 12 Dual Door Mode 0 or 1 13 14 Not Used Not Used Alarm Relay Output Relay Com Data 1 Tracker Communication Line Data 0 (-) 12VDC Battery (+) 12VDC Back-Up Ground - Required RESET Board Power 16.5 VAC, 20 VA Required ENT LED Display Programming Buttons Basic Programming Sequence on EACH Tracker Expansion Board Follow these basic steps to perform desired programming, See programming options table for PROGRAM STEPS. 1. Press arrow buttons or ENT button to ACTIVATE LED display. 2. Press arrow buttons again to CHOOSE desired PROGRAM STEP. IMPORTANT Display Decimal Point Note 3. Press ENT button to ENTER desired PROGRAM STEP. (LED display number will blink after ENT button has been pressed). 4. Press 4 arrow buttons to choose SELECTION NUMBER for desired function of program step. When decimal point is NOT displayed: Indicates that you are IN a program step. 5. Press ENT button to program SELECTION NUMBER for desired function of program step. (Function has now been programmed into board). 5 15 Aux Relay Functions 0 - 12 6. Press ENT button again to exit programming OR after 10 seconds, board will automatically exit programming. After all tracker expansion boards have been programmed..... Alarm Relay Functions Manage the Complete Access Control System from Your PC Refer to the DKS Remote Account Manager Software to program and manage the complete system. SO INS FTW TA AR LL E ED TELEPHONE ENTRY SYSTEM SP ABC DEF GHI JKL MNO TUV WXYZ 1 4 PQRS 7 2 5 8 3 6 9 OPER Your PC connected to the access control system. Either IM Server OR TCP/IP OR RS-232 OR Modem to Modem Connection. See PC Programmable Telephone Entry and Access Control Systems Installation/Owner’s manual for more information about connection options. 6 7 8 9 10 11 12 Note: Repeat these steps for all other desired programming functions. Each tracker expansion board will have to be INDIVIDUALLY programmed with desired functions. 0 HOLD TO SCAN OPERATING INSTRUCTIONS 1. Use “A to Z” Buttons to Locate Name and Code Number on Display. Names are In Alphabetical Order. 2. T o Call, Enter Code Number on Keypad or Press “Call” Button. If Line is Busy, Press “#” or “Call” to Hang Up. Try Again. 3. Enter on Open Display and Tone. A Z CALL Door Operation Note: PROPER Condition: The access control system OR request to exit device HAS activated the OUTPUT RELAY on the tracker expansion board and the door contact switch is CLOSED (Door is OPEN). This indicates that the door has been PROPERLY OPENED. 16 FORCED Condition: The access control system OR request to exit device has NOT activated the OUTPUT RELAY on the tracker expansion board and the door contact switch is CLOSED (Door is OPEN). This indicates that the door has been FORCED OPENED. 17 18 19 20 21 Not Used Not Used Reset to Factory Defaults View RF POT Setting View RF Signal Loss 22 Card Code Forwarding Copyright 2013 DoorKing, Inc. All rights reserved. Function Sets Strike Time for output relay (term 25 & 26) 0.25 second strike time Strike time in 1-second increments Set Strike Time for RX (Request to Exit) of output relay (input at term 18) 0.25 second Egress Strike time Egress Strike time in 1-second increments Timer starts when valid access has been granted. 1 second Door Ajar Timer Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds Timer setting for Aux Relay activation in 5-second increments 1 second Door Ajar Timer Timer set in 5-second increments: 01 = 5 seconds, 10 = 50 seconds Set Strike Time for RX (Request to Exit) of Aux relay (ONLY available if Dual Door Mode step 12 is ON) 0.25 second Egress Strike time Egress Strike time in 1-second increments Set RX (Request to Exit) function. Activate Output Relay or do not Activate Output Relay Do Not Activate Output Relay or Reader Beeper/LED when RX input is received Activate Output Relay and Reader Beeper/LED for Free Exit Strike Time when RX received Sets type of Door Switch contacts 0 N.O. contact from door switch with Door Closed (Circuit Open - CO) 1 N.C. contact from door switch with Door Closed (Circuit Close - CC) Turns on Auto Relock function (not available if Dual Door Mode, step 12 is ON) 0 Output Relay is activated for Strike Time 1 Door Contact Switch required. If door returns to closed position during Strike Time door will “relock” after 1 second, even if strike time has not expired. Sets how BEEPER or LED will function during Hold Open 0 When Hold Open occurs, Beeper or LED is active only during Strike Timer 1 When Hold Open occurs, Beeper or LED will remain active during Hold Open Sets how Aux & Alarm Relay responds during Hold Open or Hold Egress situation 0 No Aux Relay functions. Alarm will be in “Reset”. If Alarm Relay is set for “integral” mode, Alarm relay will not activate. If Alarm Relay set for “Bypass” mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold. 1 Aux Relay will function for all settings. If Alarm Relay is set for “integral” mode, Alarm relay will not activate. If Alarm Relay set for “Bypass” mode, Alarm Relay will activate for Hold Open period or Extended Egress Hold. Sets Tracker to function as 2 Access Points (2 tracker addresses) 0 Disabled, Tracker functions as single access point Dual Mode: Tracker functions as set board address and next sequential address 1 Card Read will be sent to controller as set board address, access is granted or denied Card then sent as set address +1, access granted or denied. Aux Relay becomes 2nd output relay. All other Aux Relay functions disabled. Door Contact switch becomes RX (Request to Exit) for 2nd address. 0 1 2 3 When decimal point is displayed: Indicates that you are SELECTING a program step. 120 Glasgow Avenue Inglewood, California 90301 0 1 2 0-4 3 4 Sets function for Aux Relay Aux Relay Disabled No Door Ajar Timer: Requires Door Contact Switch. Aux Relay activates when Door Not Closed. No Door Ajar Timer, Pulse: Requires Door Contact Switch. Aux Relay “pulses” when Door Not Closed. Door Ajar Timer: Requires Door Contact Switch. When door opens, start Door Ajar Timer. When timer expires Aux Relay activates for Aux Relay timer or until door closes, whichever occurs first. Door Ajar Timer, Pulse: Requires Door Contact Switch. When door opens, start Door Ajar Timer. When timer expires Aux Relay Pulses for Aux Relay timer or until door closes, whichever occurs first. Door Ajar, Pulse warning the ON: Requires Door Contact Switch. When door opens, Pulse Aux Relay and start Door Ajar Timer. When timer expires Aux Relay ON for Aux Relay timer or until door closes, whichever occurs first. Door opens for any reason, Start Door Ajar timer and pulse Aux Relay. When Door Ajar timer expires, start Aux Timer and continue Pulsing Aux Relay. When Door Closes or both timers expire, turn off Aux Relay Aux Relay as 2nd Alarm Relay. Aux Relay will mirror Alarm Relay functions. Aux Relay as 2nd Alarm Relay, PULSE. Aux relay will Pulse during any Alarm Relay activation. Good Card: Aux Relay will activate for Aux Relay timer for any Access Granted Card Any Card: Aux Relay will activate for Aux Relay Timer when any card has been presented. Bad Card: Aux Relay will activate for Aux Relay timer when a card has been denied Warn before Hold Open or Release of Hold Open: Aux relay will activate for Aux Relay timer when scheduled Hold Open begins or ends. Output Relay will be delayed until Aux Timer expires. DO NOT set Aux Timer above 60 seconds in this mode. Sets function for Alarm Relay Aux Relay Disabled Bypass Mode: Alarm Relay provides “Bypass” to Alarm Door Switch. With proper door input (access or egress) activate Alarm Relay, start Strike timer and Door Ajar timer. When Door Ajar timer expires, deactivate Alarm Relay. If second Door Contact Switch is provided, generate transaction for Door Ajar and Door Closed following Door Forced condition. Also generate transaction for Door Forced condition. Integral Mode, Door Ajar Timer: Door Contact Switch connected to Tracker, Alarm Relay provides connection directly to Alarm System. When door is opened for any reason, start Door Ajar timer. When Door Ajar timer expires and Door is still OPEN, activate Alarm Relay. Reset when door closes. Send Door Ajar and Door Close transactions. Integral Mode, Proper and Forced condition: Door Contact Switch connected to Tracker, Alarm Relay provides connection directly to Alarm System. With proper door input (access or egress) start Strike timer and Door Ajar timer. When Door Ajar timer expires and Door is still OPEN, activate Alarm Relay. Reset when door closes. If door is opened without proper condition, activate alarm relay. When door closes deactivate Alarm Relay. Send Door Ajar, Door Close and Door Forced transactions. Gate Alarm Function: Alarm Relay will activate for 1 second when tracker board receives a “Gate Forced” or “Gate Obstructed” transaction from the operator control board. 5 Sets all parameters to Factory Default 5 Adjustable Setting Sets maximum amount of allowable signal strength loss Displays on LED Displays current signal loss between Base and Tracker. Sets Wireless Tracker to act as Repeater ONLY USE AS DIRECTED BY DOORKING TECH SUPPORT 0=Repeater Mode OFF 1=Repeater Mode ON 0 or 1 U.S.A. Rev-E 1-13-14 Factory Default 01 - 1 second 01 - 1 second 12 - 60 secs 12 - 60 secs 01 - 1 second 1 - Activate 0 - N.O. 0 - Disabled 0 0 - No relay functions 0 - Disabled 0 - Disabled 0 - Disabled 0 - Off 2358-066-F-2-14