Lamps - HIDirect

advertisement
Your One-Stop
Connection For
Replacement and
Retrofit Lighting
Solutions!
Lamps
Ballasts
HID Lighting
Product Catalog
Fixtures
Applications Introduction
Natural
White™
Horizontal
PS Lamps
UNI-FORM®
Systems
Retrofit
Systems
Specialty
Lamps
HPS Lamps Probe Start
and Ballasts MH Systems
Reference
Guide
Product
Index
Table of Contents
INTRODUCTION INFORMATION
Introduction
Who is HIDirect . . . . . . . . . . . . . . . . . . . . .1
Mission statement and how to order . . . . . . . .2
VIP program . . . . . . . . . . . . . . . . . . . . . . . .2
Applications
Shopping mall lighting . . . . . . . . . . . . . . . . .4
Grocery store lighting . . . . . . . . . . . . . . . . .5
Automobile Dealership lighting . . . . . . . . . . .6
Gymnasium lighting . . . . . . . . . . . . . . . . . . .7
Outdoor sports lighting . . . . . . . . . . . . . . . . .8
Arena lighting . . . . . . . . . . . . . . . . . . . . . .9
Highbay industrial lighting . . . . . . . . . . . . .10
Manufacturing lighting . . . . . . . . . . . . . . . .11
Parking garage lighting . . . . . . . . . . . . . . .12
Parking lot and site lighting . . . . . . . . . . . . .13
Guide of product by application . . . . . . . . .14
Natural White®
Pulse Start Systems
90% mean lumens, high CRI and high color
temperature (5000K) product that delivers the
same color as sunlight
Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Retrofit
System Solutions
Electronic ballast housings . . . . . . . . . . . . .42
Magnetic ballast housings . . . . . . . . . . . . . .43
Track lighting systems . . . . . . . . . . . . . . . . .44
Specialty Lamps
Energy Master® . . . . . . . . . . . . .
White-Lux® . . . . . . . . . . . . . . . .
High wattage/Sports lighting . . .
Tubular lamps . . . . . . . . . . . . . .
Double ended and G12 lamps . .
High wattage double ended lamps
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.46
.48
.49
.50
.51
.52
Probe Start
Metal Halide
Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .54
Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Wiring diagrams . . . . . . . . . . . . . . . . . . . .58
HPS Lamps and
Ballasts
High Pressure Sodium lamps . . . . . . . . . . . .59
High Pressure Sodium ballasts . . . . . . . . . . .60
Wiring diagrams . . . . . . . . . . . . . . . . . . . .62
Horizontal
Guide
Pulse Start Systems Reference
Trouble Shooting Guide . . . . . . . . . . . . .64-65
The first pulse start systems designed for
horizontal operation
200, 250, 320, 350 and 400 watt . . . . . . .20
Uni-Form®
Pulse Start Systems
50 watt . . . . . . . . . . . . . . . . . . . . . . . . . .22
70 watt . . . . . . . . . . . . . . . . . . . . . . . . . .23
100 watt . . . . . . . . . . . . . . . . . . . . . . . . .24
125 watt . . . . . . . . . . . . . . . . . . . . . . . . .25
150 watt . . . . . . . . . . . . . . . . . . . . . . . . .26
175 watt . . . . . . . . . . . . . . . . . . . . . . . . .27
200 watt . . . . . . . . . . . . . . . . . . . . . . . . .28
250 watt . . . . . . . . . . . . . . . . . . . . . . . . .29
320 watt . . . . . . . . . . . . . . . . . . . . . . .30-31
350 watt . . . . . . . . . . . . . . . . . . . . . . .32-33
400 watt . . . . . . . . . . . . . . . . . . . . . . . . .34
450 watt . . . . . . . . . . . . . . . . . . . . . . . . .35
575 watt . . . . . . . . . . . . . . . . . . . . . . . . .36
875 watt . . . . . . . . . . . . . . . . . . . . . . . . .37
1000 watt . . . . . . . . . . . . . . . . . . . . . . . . .38
Go Green: Retrofit and Save . . . . . . . . . . . .39
Wiring diagrams . . . . . . . . . . . . . . . . . . . .40
Replacement Sockets . . . . . . . . . . . . . . . . . . .66
Replacement Ignitors and Capacitors . . . . . . . .67
Capacitor and Ignitor Diagrams . . . . . . . . .68
Lamp Shapes and Bases . . . . . . . . . . . . . . .68
Ballast Brackets . . . . . . . . . . . . . . . . . . . . .69
Glossary . . . . . . . . . . . . . . . . . . . . . . .70-71
Lamp and Ballast Cross-Reference . . . . . .72-74
Product Index
Product Description Code Explanation . . . . .75
Lamps . . . . . . . . . . . . . . . . . . . . . . . . .76-77
Ballasts . . . . . . . . . . . . . . . . . . . . . . . .78-79
Warranty information and dimming policy . .80
“One Call” Warranty registration form . . . . .81
Photo credits: . . . . . . . . . . . . . . . . . .Page Number(s)
© Steve Mulé . . . . . . . . . . . . . . . . . . . . . . . . . .25,51
© Vance Roth . . . . . . . . . . . . . . . . . . . . . . . . .8,49C
© Doug Salin . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
© Doug Walker . . . . . . . . . . . . . . . . . . . . . . . . .49B
© Héctor Armando Herrera . . . . . . . . . . . . . . .14,19
Courtesy of Electrotech . . . . . . . . . . . . . . . . . . . . .52
Courtesy of The Minnesota Wild . . . . . . . . . . . . . . . .9
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Introduction
Who is HIDirect?
INTRODUCTION INFORMATION
HIDirect
Benefits / Features
We’re your best choice for high intensity discharge (HID)
replacement lighting products and services at the best
price, including metal halide and HPS. We offer the
largest selection of in-stock metal halide products and
numerous HPS products, including replacements for GE,
Philips, Osram/Sylvania and Venture. Our vast selection
of standard probe start and pulse start metal halide lamps
and ballasts and HPS lighting is ideal for any application,
including:
• Commercial
• Factories
• Industrial
• Warehouses
• Retail
• Signs
• Security
• Canopies
• Parking Areas
• Landscape
• Sports Facilities
and more!
• Large variety - Over 1000 types of metal halide
and HPS lamps and ballast kits
• Retrofit Kits available
• Competitive pricing
• Knowledgeable customer service representatives
• Fast Service. Orders in by 3pm EST ship same
day for in-stock products! (next day delivery also
available)
• Get an extra 5% off your purchase using Visa,
MC or AMEX
HIDirect’s Headquarters
Streetsboro, Ohio, U.S.A.
• No-fee recycling service (ask for details)
• FREE volume shipping, ask for details
• No minimum order requirement
• Ask about our VIP program
Why HIDirect?
HIDirect is the factory-direct distributor of the world’s
leading designed metal halide lighting systems, including
Uni-Form® pulse start metal halide systems with the formed
body arc tube. We ship all in-stock items the same day
you place your order. You’ll have access to the largest
selection of standard probe start, pulse start, specialty
and energy-saving lamps and ballasts at the best prices.
“I love working with
HIDirect. When I can buy
factory-direct pricing on a
great product, that’s what it’s
all about. Who doesn’t want
to save money? HIDirect cuts
out the middle man and I
can buy my lamps straight
from them.”
-Satisfied HIDirect Customer
Factory Direct
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
1
Introduction
Benefits
Who is HIDirect?
of HIDirect
INTRODUCTION INFORMATION
Our Commitment to You
Our Mission Statement
We’re specialists in the HID lamp and ballast market and
we promise to supply the right lamp and ballast for your
application. Our knowledgeable customer service
representatives guarantee your satisfaction.
To be the best specialty lighting supplier in North America
of metal halide and HID systems including lamps,
ballasts, fixtures, ignitors and capacitors, providing:
Greener Ballasts
HIDirect supports the green energy initiatives of
California Title 20 and the Energy Independence &
Security Act of 2007, which mandate that
metal halide fixtures manufactured in 2009
must contain pulse start ballasts that are at
least 88% efficient. We agree with the need to
move away from less energy efficient standard
probe-start technology and strongly recommend that
more efficient and “green” pulse start technology be
embraced by all of our customers immediately. Our
compliant ballasts have been designated by the green
leaf by the product number. For more information about
this legislation, visit our website.
2
• The highest quality value-added customer solutions
• Advanced products
• Fastest delivery
• Knowledgeable customer service staff
• Competitive prices
How to Order
Not only does HIDirect give you expert service and
competitive pricing, we’re here longer to serve your HID
needs better. We’ve extended our phone hours to
accommodate any schedule! We can be reached toll-free
at 800-965-2677 from 7:00 a.m. to 5:00 p.m., Monday
- Friday EST.
Or, you can reach us anytime by fax at 800-865-2677
Or online at HIDirect.com! Email us at custserve@hidirect.com
Savings
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Case Studies
APPLICATION SPECIFIC PRODUCT GUIDE
Creating the Right System For
Any Application
Looking For an Application?
This section shows the many uses and advantages of
HIDirect’s metal halide lighting products, such as Uni-Form®
pulse start lamps, Opti-Wave® ballasts, sports and specialty
lighting products.
Shopping Mall Lighting . . .
Grocery Store Lighting . . .
Auto Dealership Lighting . .
Gymnasium Lighting . . . . .
Outdoor Sports Lighting . .
Arena Lighting . . . . . . . .
Highbay Industrial Lighting
Manufacturing Lighting . . .
Parking Garage Lighting . .
Parking Lot Lighting . . . . .
Street Lighting . . . . . . . . .
The wide variety of applications and possibilities, in
combination with benefits such as energy savings and better
quality light, HIDirect is your clear choice for metal halide
products.
Application-Product
Selection Guide
System
Page
Applications
Application Type
.Various Wattages . . . . .4
.320W . . . . . . . . . . . .5
.Various Wattages . . . . .6
.450W . . . . . . . . . . . .7
.Various Wattages . . . . .8
.1000W . . . . . . . . . . .9
.875W . . . . . . . . . . .10
.450W . . . . . . . . . . .11
.200W . . . . . . . . . . .12
.400W . . . . . . . . . . .13
.Horizontal pulse start .14
Looking for a light source for a particular application? This
application-product guide is your source for finding the
right Uni-Form® pulse start metal halide system.
Pulse Start System Wattage
50 70 100 125 150 175 200 250 320 350 400 450 575 775 875 1000
Architectural Applications
Retail/Big Box
Grocery Story on page 5
Airport
Security
•
Parking Garage Story on page 12
Retail Auto Lots Story on page 6
Roadways
Gas Station Canopy
Lowbay Industrial
Highbay Industrial Story on page10
Aircraft Hangers
Food Processing
Hazardous Locations
Indoor Sports Story on page 7
Sign Lighting/Billboards
Landscape
•
Lecture Halls
Convention Centers
Site/Parking Lot Story on page 13
Warehouse
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Luminaire Applications
Lowbay
Highbay
Wallpack
Floodlight
Canopy Light
Sign Lighter
Hazardous
Vertical Lamp Area Cutoff
Horizontal Lamp Shoebox
Recessed Downlight
Indirect Lighting
Well Lights
Bollards
Sconce
Electronic Dimming
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Applications
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
3
Uni-Form Systems Case Study
®
Applications
APPLICATION SPECIFIC PRODUCT GUIDE
Shopping Mall
More Light and Less Energy
“SuperMall of The Great Northwest”, located just east of
Tacoma in Auburn, WA is an over one million square foot
shopping complex serving over 7,000,000 customers
annually. Opened in 1995, SuperMall is just 1 of 24
malls owned and operated by Glimcher Realty Trust,
which is headquartered in Columbus, Ohio.
what the Uni-Form pulse
Glimcher Realty Trust malls are in the process of updating
lighting in all areas, and recently began this process with
SuperMall of the Great Northwest. Paul Hensley,
operations director of the mall, was looking for “more
uniform brighter light, with energy savings”. SuperMall
turned to United Lamp Supply of Tacoma, WA. Karl
Willard, Sales Manager for United Lamp, with more than
20 years of lighting experience himself, managed the
project from beginning to end.
start product has delivered.
Challenges and Results
We’re very satisfied.
Initially, (240) 1000W standard probe start lamps and
ballasts were replaced by the energy efficient 875W
pulse start lamps and ballasts in the mall’s various
parking lots. The 875W systems saved 155 watts per
fixture and footcandle readings were a full 37% higher
than with the previous systems. Since the photometrics of
the lamps were the same, the existing parking lot poles
and fixtures did not need to be changed, significantly
reducing installation costs.
“We were looking for more
uniform brighter light, with
energy savings and that’s
”
-Paul Hensley,
Operations Director
4
In the food court areas of the mall, (91) 250W standard
probe start lamps and ballasts were replaced with 200W
Uni-Form® pulse start systems. (35) 400W standard
probe start lamps and ballasts were replaced with 320W
Uni-Form pulse start systems. In the various entrances of
the mall, (32) 175W standard probe start lamps and
ballasts were replaced with 150W Uni-Form pulse start
lamps and ballasts. Paul Hensley is happy to report that
the initial introduction to each mall entrance now plays a
more positive role in the overall shopping experience for
SuperMall customers.
Saving from Rebates
As incentive for using this energy efficient technology,
SuperMall received an energy rebate from the local utility,
Puget Sound Energy. The mall received an up-front
rebate of $156,000.00, which enabled them to reduce
the pay-back period in half.
Benefits:
• Brighter, better quality lighting
• Energy Savings
• Energy utility rebates, reducing pay-back period
• Excellent color uniformity
The Uni-Form® pulse start 150W, 200W,
320W, 875W details can be found on pages:
26, 28, 30, 37.
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Electronic 320W Case Study
APPLICATION SPECIFIC PRODUCT GUIDE
Applications
Grocery Store
The Metal Halide Innovator
In grocery stores, lighting can play a significant role in
assisting shoppers in locating items on shelves and in
highlighting important features of those items. Attractive
displays encourage customers to browse and buy, leaving
them satisfied and more likely to return. The grocery
store industry is extremely competitive, and any feature
more pleasing to a customer can mean the difference
between success and failure during the shopping
experience. Grocery stores with lights that are bright
with an appealing color are more likely to entice
customers to shop at their location rather than at a store
with lighting that creates a gloomy atmosphere.
In the example pictured, a Charlotte, NC grocery store
took advantage of HIDirect’s HF electronic ballast
housing/fixture. This choice enabled them to not only
display their grocery store items in the most appealing
manner possible, but also to achieve significant energy
savings in the process.
Many grocery store chains are looking for even greater
color rendering of their stocked items, and are choosing
Natural White® pulse start products. The high 90+ color
rendering (CRI) and 5000K color temperature of this
product line displays grocery items in the best possible
light, providing a natural sunlight atmosphere to any
store location. Color sensitive items such as produce and
meats are displayed in a much brighter and appealing
light.
Benefits:
• Improved lumen maintenance on electronic system
• Excellent color uniformity
• With electronic system, 2 year 100% lamp warranty
The Uni-Form® 320W details can be found on
page 16
5
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Natural White Case Study
®
Applications
APPLICATION SPECIFIC PRODUCT GUIDE
Auto Dealership
Whiter Light and Less Energy
New Car Pickup Area
The Classic Auto Group, located in Northeast Ohio,
offers a huge variety in automobile choices ranging from
Chevrolet to Lexus and Cadillac. At their Toyota
dealership, they replaced outdated standard probe start
metal halide technology with new state-of-the-art Natural
White® pulse start technology.
Classic also replaced a variety of fixtures in their new car
pickup area with (22) low wattage track lighting systems.
As a Natural White product, HIDirect’s MR16’s offer high
energy efficiency, high color rendering and maximum
light “punch”, all in a compact size with tight beam
control to put the light right where you want it. Classic is
extremely pleased with its new Natural White lighting
and all the benefits it has brought to the Mentor
dealership.
Car Lot Lighting
“We’re extremely pleased
with the lighting. At night,
our dealership shines like a
diamond. From just the
better lighting alone,
I’ll sell more cars.
”
-Bob Ringo,
Classic Automotive Group
6
Classic replaced (121) 1000-watt standard probe start
lamps and ballasts in their Mentor car lot with 775-watt
Natural White lamps and ballasts. This resulted in a
huge decrease in energy consumption of over 25%. The
lot draws attention to the dealership by all who pass due
to the brighter and “whiter” lighting.
Service Bays and Showrooms
In its service bay area, Classic replaced (56) 400W
standard probe start lamps and ballasts with the same
number of energy saving retrofit 450W Natural White
pulse start systems. The light output was increased by
60%. An improved overall work atmosphere, which was
more conducive to fewer servicing errors, was achieved.
In the showroom, (24) 400W standard probe start lamps
and ballasts were replaced with 400W Natural White
pulse start lamps and ballasts.
Benefits:
• High CRI lighting, 90+ with daylight color: 5000K
CCT, which is perfect for daylight harvesting
• 90% mean lumens - A first in HID industry!
• With electronic system, 2 year 100% lamp warranty
Comparisons
Quantity
of Lighting
Systems
Car Lot
121
Service
56
Bay Area
Showroom 26
Existing
Wattage
1000W
400W
400W
Upgraded Annual
System
Energy
Wattage
Savings
775W $11,616.00
290W
$3,091.20
400W
$1,123.20
Total: $15,830.40
Total of 25% Reduction of Energy Usage
(Based on 5000 hours/year at $0.08/kWh)
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Electronic 450W Case Study
APPLICATION SPECIFIC PRODUCT GUIDE
Applications
50% Power
Full Power
Gymnasium Lighting
Daylight Harvesting &
Dimming of College Athletic
Facility
Benefits:
A major university in the Southeast was looking to provide
good quality white light in its gymnasium, with the ability to
save energy and operating costs by dimming those lights as
well as utilize cost-free daylight harvesting.
• Up to 86% mean lumens
By using HIDirect’s 450 watt e-Lamp® product, which is a
Uni-Form® pulse start lamp optimized for use on HIDirect’s
Ventronic™ electronic ballasts, the university was able to
significantly reduce its overall energy consumption and
operating costs. Utilizing dimming technology with the
lamps allowed the facility to take advantage of the natural
light of the sun through daylight harvesting.
Uni-Form pulse start 450W e-Lamp benefits:
• Long life: 20,000++ hours
• Ballast efficiency up to 95%
• Significant energy savings
The Uni-Form® 450W details can be found on
page 35
The university utilizes a sophisticated dimming system,
capable of dimming the 450W lamps to a full 50% of
power output. Over 4 different light output settings can be
used for various functions, such as basketball practice would
be at 75% lamp power while actual games would be lighted
at full power. When dimming, the university significantly
reduces its energy usage, while getting quality “free” light
directly from the sun.
7
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Sports Lighting Case Study
Applications
APPLICATION SPECIFIC PRODUCT GUIDE
Outdoor Sports
Lights that Bring Their A-Game
For professional, semi-professional and amateur sporting
events, bright white light shining down is essential for
enabling fans to view the events and their favorite teams
and athletes in the best possible way. Good color
rendering of lighting sources is also very important not
only in effectively displaying uniform and stadium/arena
colors, but also for allowing sports fans to most effectively
view scoreboards and other areas that are part of
outdoor venues. It is important that good lighting is
maintained even during adverse weather conditions,
including heat or cold.
HIDirect’s metal halide lamps and ballasts are the lighting
technology of choice to provide superior and bright white
light, as well as excellent color rendering during all types
of weather conditions. From major league baseball
organizations to minor league teams, as well as for a
plethora of amateur sporting venues, HIDirect’s 1500W
and 1650W lamps can be focused accurately on sporting
events, providing long lamp life and bright white light.
As a typical example, 115 luminaires consisting of
HIDirect’s 1500W horizontal sport lamps are utilized in
Lelacher Park in Lowell, Massachusetts. Lelacher Park is
home of the Boston Red Sox’s Class A farm team. With
a seating capacity of 5,000 fans, this park also plays host
to the nearby University of Lowell’s spring and fall
baseball games. These lamps provide many, many hours
of great lighting for a multitude of baseball contests.
Benefits:
• Position oriented horizontal applications up to 60° tilt
• Unique cross pinch design for stable light output
• High lumen output (1650 watt), 177,000 lumens
and 107 lumens per watt for optimal horizontal and
vertical illuminance
• 3200K - 4000K color
Sports Lighting lamp details can be found on
page 49
8
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Sports Lighting Case Study
APPLICATION SPECIFIC PRODUCT GUIDE
Applications
Arena Lighting
HIDirect is an All Star
Lighting sports and entertainment facilities such as Xcel
Energy Center in St. Paul, Minnesota makes HIDirect an
all-star in lighting. The 650,000 sq. ft. Xcel Energy Center
is home to the National Hockey League’s Minnesota Wild,
the 2004 NHL All-Star game and four World Cup of
Hockey games.
The NHL demands quality lighting for televising games.
This includes rendering players’ jerseys in true color and
adequately lighting the ice rink and fans in the arena’s
first 30 rows. HIDirect’s MS 1000W/HOR/BT37/3K
lamps produce the necessary 125 foot candles of vertical
illumination, high color rendering and light quality. The
lighting design called for 340 luminaires, but the light
output produced by the lamps helped reduce that number
to 280 luminaires.
“They’re great lights,” said Mark Anger, director of
Facilities Development for Minnesota Sports &
Entertainment.
HIDirect’s lamps also light the American Airlines Center,
Conseco Fieldhouse, Pepsi Center, Staples Center and
First Union Arena.
Benefits:
• Position oriented super metal halide for maximum
light output
• Reduced outer jacket size for precise optical control
• Warm 3400K color
The 1000W Horizontal lamp details can be
found on page 55
“They’re great lights“
-Mark Anger,
director of Facilities
Development for Minnesota
Sports & Entertainment.
9
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
875W System Case Study
Applications
APPLICATION SPECIFIC PRODUCT GUIDE
Highbay Industrial
“We’re extremely pleased
with the changes resulting
from the lighting throughout
the facility. We were able to
achieve our goals. It was a
doubling of the light output
with nearly half the number
of lamps.
”
The Steel Mill’s Electrical
Maintenance Manager
10
Improving Worker Safety
Making a Positive Difference
A 1.3 million square foot steel mill located near Gary,
Indiana is aware of the importance to the ecology of the
surrounding countryside, and works continuously to
improve its operations to become more environmentally
friendly. In November of 2006, they looked into
replacing hundreds of their older and energy inefficient
standard probe start metal halide, mercury vapor and
high pressure sodium lamps with a more energy efficient
lighting technology, hoping to significantly reduce energy
usage and improve safety and the productivity of the
workers.
Worker attitudes improved noticeably once the new
lighting systems were installed. Management received
thanks from workers, and complaints of the previous
lighting stopped. Thanks to the improved lighting, the mill
experienced one of its safest years in their over 40 year
history! The plant’s operations manager noted, “the new
lights resulted in doubling the light output with nearly half
the number of lamps”. For further energy savings, remote
lighting controls were utilized to turn various lamps on
and off as needed in specific areas of the mill.
They were utilizing (1190) 1000 watt standard probe
start metal halide, (340) 1000 watt mercury vapor and
(170) 400 watt high pressure sodium high bay lights.
Choosing HIDirect’s 875 watt pulse start system, they
were able to reduce the fixture count by 44%, resulting in
a 50% energy savings. In various parts of the mill, entire
rows of lamps could now be eliminated due to the
exceptional light output of the HIDirect® lamps! Overall,
(952) 875 watt pulse start metal halide systems replaced
the original (1700) systems. They were able to reduce the
total number of lamps, ballasts and fixtures resulting in a
reduction of inventory and lighting maintenance costs.
Benefits:
• Twice the light
• Annual savings of over $400,000
• Reduction of Energy Usage by 50%
Comparisons
875 Watt Pulse Start
vs
Previous Systems
952
Number of Fixtures
1700
20,000+
Lamp Life Hours
12,000
50
Average footcandles
14
7.8 Million
Energy Consumption 15.1 Million
for Lighting (kWh)
$400,000 Total Annual Savings
0
for the one facility
50%
Energy Savings
0
The pulse start 875W details can be found on
page 37
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
350W Natural White Case Study
®
APPLICATION SPECIFIC PRODUCT GUIDE
Applications
Manufacturing
Improved Light Quality &
Saved Energy
Existing 400W high pressure sodium (HPS) lamps utilized at
a Northeast aircraft manufacturer’s facility was not
delivering the quality or light level necessary for most
manufacturing operations. The typical “yellow” light
provided by HPS lamps was ineffective at rendering colors
accurately on the production floor, resulting in poor quality
and overall productivity. In addition, this existing lighting
system was very energy inefficient, resulting in higher than
acceptable monthly energy costs.
A local lighting specialist recommended utilizing HIDirect’s
350W Natural White® pulse start metal halide lamps in
combination with electronic ballasts as the ideal solution.
The light from Natural White lamps mimics that from natural
sunlight, resulting in a brighter and more natural looking
work space.
Benefits:
• Energy savings: over 50% improvement in mean
lumens per watt vs. 400 watt standard probe start
metal halide system
• Long life: 20,000+ hours
• Improved color uniformity
• Optimized lamp/ballast systems for superior
performance
• Higher CRI of 90+ over HPS lamps at 22 CRI
The 350W Natural White lamp details can be
found on page 16
In switching to Natural White pulse start technology, this
manufacturer immediately obtained the brightest and best
possible lighting system available, while also achieving
good energy savings. As an added bonus, this system
provided 90% lumen maintenance, meaning that the
Natural White lamps are providing nearly the same higher
light output years after their initial installation.
11
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Uni-Form Systems Case Study
®
Applications
APPLICATION SPECIFIC PRODUCT GUIDE
Parking Garage
Minneapolis-St. Paul International Airport, one of the
busiest airports in the world, recently completed a
comprehensive lighting retrofit in its parking garage,
switching from standard probe start metal halide lamps
to more energy efficient Uni-Form® pulse start metal
halide lamps.
The decision to switch to this technology was made even
easier when the local power company, Xcel Energy,
offered the airport a substantial rebate for retrofitting with
pulse start technology. HIDirect’s energy saving 125 and
150 watt Uni-Form pulse start metal halide lamps were
the lamps of choice to retrofit the current system.
Ready to Relamp
Brighter Future for Airport
After many years of constant use, the 175, 250, and
400watt standard probe start metal halide lamps in the
airport parking garage needed relamping. Due to tight
budget constraints in the air travel industry, energy
savings was a key consideration in specifying the new
lamps, and airport management did not want to sacrifice
light output to cut energy costs.
The six month project involved the installation of more
than 4,000 lamps and ballasts in the parking garage
structure. Airport management was ecstatic with the result
of the retrofit: “We doubled our light levels!” said Bob
Litke, Electrical/General Foreman for the Metropolitan
Airports Commission,“ and with the substantial energysavings, we should begin seeing a return on our
investment in only one year.”
By switching to new Uni-Form pulse start metal halide
technology, the airport would see immediate benefits.
These benefits ranged from large yearly energy savings,
reduced maintenance costs based upon the extended
lamp life, increased light output, and better color
rendering for improved security and easier identification
of the customers’ cars. Uni-Form pulse start metal halide
lamps were recommended. They outperform standard
probe start metal halide lamps by providing energy
savings, long life (20,000+ hours) and increased light
output over the life of the system.
Benefits:
• Energy savings
• Longer lamp life: reduced maintenance costs
• Double the light output
• Better color rendering for improved security and
easier identification of the customers’ cars
The 125W Uni-Form lamp details can be found
on page 25. The 150W Uni-Form lamp details
can be found on page 26.
12
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
775W Natural White Case Study
®
APPLICATION SPECIFIC PRODUCT GUIDE
Applications
Parking Lots
More Light and Less Energy
In Murfreesboro, TN, located 40 miles south of Nashville,
Innsbrooke Plaza is a 150,000 square foot shopping
complex. In early 2008, Inland Continental Property
Management, the developer of Innsbrooke Plaza, was
looking to improve the overall lighting output in the
parking areas of the mall. The existing lighting consisted
of (6) lighting poles 39’ in height, each of which held (4)
1000W high pressure sodium lamps in vertical semicutoff luminaires. High pressure sodium lamps cast a
yellowish light, making it difficult for shoppers to see well
at night, and provide very poor color rendering, making
the identification of one’s automobile in the lot difficult as
well.
To achieve the goals of improved lighting levels and
quality, and reduced energy consumption and
maintenance, HIDirect’s 775W Natural White® pulse start
metal halide systems were used in combination with
sharp cutoff luminaires in a one-for-one replacement of
the high pressure sodium systems. Natural White lamps
provide whiter and brighter light due to superior color
rendering; a color temperature of 5000K essentially
matches the color of natural sunlight. By switching to this
much lower wattage option, Innsbrooke was able to
achieve an incredible reduction of 255 watts per fixture,
resulting in 23% less energy consumption, and the
superior “white” light output of the 775 watt lamps
increased footcandles in the parking lot by 60%!
Inland and Innsbrooke Plaza are pleased with their new
“whiter” Natural White pulse start lamps and ballasts.
Not only were all initial goals of improved light levels,
reduced energy consumption and improved lighting
maintenance met and surpassed, yet in addition,
Innsbrooke is now benefiting from an annual energy
savings of $4,000!
Benefits:
• High CRI lighting, 90+ with daylight color:
5000K Correlated Color Temperature
• 90% mean lumens
• Energy savings of 255 watts per fixture
• Lower maintenance costs
Comparisons
Natural White®
1000W High
775W
vs
Pressure Sodium
24
Number of Fixtures
24
845
System Watts
1100
90+
CRI
23
5000K
Color Temperature
2200K
(Blue-White)
(Yellow-Orange)
$4,000/year
Savings
0
25%
Energy Savings
0
The 775W Natural White system details can be
found on page 16.
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
13
Uni-Form Systems Case Study
®
Applications
APPLICATION SPECIFIC PRODUCT GUIDE
Street Lighting
The Metal Halide Innovator
Mexico City, with its more than 20 million residents, was
in search of street lighting, which would provide better
visibility at night. With a preponderance of high pressure
sodium lamps used, HPS may have long life, but their
distinctive “yellow” glow reduces overall visibility during
the night, creating public safety and security issues, a
major concern of one municipality.
“It’s a great investment not
only in the city’s beauty but in
its public security. The new
lighting technology has
changed the city’s panorama
”
completely.
-Antonio Gershensen
Public Lighting Director of
Mexico City
14
In the summer of 2005 the Mexico City municipality
utilized 36,000 of HIDirect’s 200 watt Uni-Form®
Horizontal pulse start lamps for street lights. About 60%
of these lamps were used to retrofit existing HPS lamps,
while the remaining lamps were for entirely new
installations. “It’s a great investment not only in the city’s
beauty but in its public security. The new lighting
technology has changed the city’s panorama completely”,
stated Antonio Gershensen, Public Lighting Director of
Mexico City.
Studies have shown that metal halide lighting, which
utilizes more visible “white” light, can have a visibility
effectiveness of up to six times that of HPS when used at
night. Gershensen further noted: “This kind of lamp gives
30% more light than the old yellow ones (HPS), they have
longer life and they represent an important development
in color fidelity. The lamps not only last longer but also
give more brightness and clearness.”
Mario Bonilla Ramirez, Coacalco County Under Director
of Public Services, also notes that these lamps have
resulted in “a diminishing of 25% in the small felonies in
the streets.”
Per Jim McPhillips, lighting consultant, the success in
Mexico City has “resulted in the largest metal halide
project in all of Latin America!” And Reforma, the most
important daily newspaper in Mexico, identified this
municipality as “the best public lighting system in the
entire metropolitan area of Mexico City.”
Benefits:
• 24% more maintained lumens than 250 watt
standard probe start metal halide, 85% more than
175 watt standard probe start metal halide
• Twice the life of 175 or 250 watt standard probe
start systems
• 95 lumens per watt and 15,000 hours of life
compared with 250W standard probe start metal
halide with 74 lumens per watt and 7500 hours of
life
The Horizontal pulse start details can be found
on page 19-20.
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Natural White
HIGH CRI
AND
®
H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Superior Color Rendering
Features
What could be more natural than sunlight? With
HIDirect’s Natural White systems, blues are true blue,
reds are more vibrant, whites are whiter, and skin tones
appear as they do under sunlight. Natural White lamps,
with 5000K color temperature and 90+ CRI, bring
daylight indoors!
• Superior color rendering; objects appear as they
would outdoors
• Work spaces look brighter; tasks, such as reading,
become easier to perform
Benefits
• 90% Lumen Maintenance (0.90 Light Loss Factor)
• Merchandise and signage are protected from fading
with UV Shield® technology - blocks nearly all
UV output
• The Color of Natural Sunlight:
5000K
90+
Natural
White®
• High CRI Lighting (Color Rendering Index)
• Excellent color uniformity and stability over life of
lamp due to formed body arc tube
• Designed for open or enclosed luminaires
• Shrouded arc tube with ANSI Type-O rating
• Operates continuously without weekly shutdowns
• Complies with 2005 NEC (National Electrical Code®)
UNI-FORM®
Systems
True Colors
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
15
Natural White Lamps
®
HIGH CRI
AND
H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Natural
White®
ELECTRONIC Ballasted Open Rated Lamps ANSI Type-O
featuring UV
Shield®
Lamp
Description
MPSE 250W/BU/UVS/950
Initial
Initial
Outdoor Indoor
Initial
Avg.
Warm1
Product Nighttime Visual Task2 Photopic
Life
CCT Up Restrike
Oper.
Case
3
No.
Lumens Lumens Lumens Hours
(K) (Min) (Min) CRI Finish
Pos. Fig. Qty
95047
22000
21000
17500 20000++ 5000 2-3 5-8 90+ Clear BU±15° A 12
MPSE 290W/BU/UVS/950
95005
28000
26500
22000
20000++ 5000 2-3
5-8
90+ Clear
BU±15°
B
MPSE 320W/BU/ED37/UVS/950
28712
30500
29000
24000
20000++ 5000 2-3
5-8
90+ Clear
BU±15°
B
6
MPSE 320W/C/BU/ED37/UVS/950
35698
28500
27000
22500
20000++ 5000 2-3
5-8
90+ Coated BU±15°
B
6
6
MPSE 350W/BU/UVS/950
62584
33000
31500
26000
20000++ 5000 2-3
5-8
90+ Clear
BU±15°
B
6
MPSE 350W/C/BU/UVS/950
71035
31500
30000
25000
20000++ 5000 2-3
5-8
90+ Coated BU±15°
B
6
MPSE 400W/BU/UVS/950
71564
38500
37000
30500
20000++ 5000 2-3
5-8
90+ Clear
BU±15°
B
6
MPSE 400W/C/BU/UVS/950
95103
37000
35000
29000
20000++ 5000 2-3
5-8
90+ Coated BU±15°
B
6
MPSE 450W/BU/UVS/950
95011
44000
41500
34500
20000++ 5000 2-3
5-8
90+ Clear
BU±15°
B
6
MPSE 450W/C/BU/UVS/950
95012
41000
39500
32500
20000++ 5000 2-3
5-8
90+ Coated BU±15°
B
6
UNI-FORM®
Systems
MAGNETIC Ballasted Open Rated Lamps ANSI Type-O M181/0
Initial
Initial
Outdoor Indoor
Initial
Product Nighttime1 Visual Task2 Photopic
No.
Lumens Lumens Lumens
24983
84000
80000
66000
Lamp
Description
MP 775W/BU/BT37/PS/950
Avg.
Life
CCT
Hours4
(K)
20000+ 5000
WarmUp Restrike
Oper.
Case
(Min) (Min) CRI Finish
Pos. Fig. Qty
3-5 8-12 90+ Clear BU±15° C
6
Energy Saving RETROFIT Open Rated Lamps ANSI Type-O featuring UV Shield®
Fun Facts
The center of the sun is about
27 million °F (15 million °C)
Initial Initial
Outdoor Indoor Photopic Avg.
Product ANSI Nighttime1 Visual Task2 Initial Life CCT
Operating Case
Watts
No.
Code Lumens Lumens Lumens Hours4 (K) CRI Finish Pos. Fig. Qty
Replaces Saved
19523 M153/O 21000 20000 16500 20000+ 5000 90+ Clear BU±15° A 12 250W/BU/ED28/PS 15
Lamp
Description
MP 250W/BU/UVS/PS/EM/950
MP 320W/BU/ED28/UVS/PS/EM/950 98530 M154/O 28500
27000 22500 20000+ 5000 90+ Clear BU±15° A 12 320W/BU/ED28/PS 20
MP 320W/BU/ED37/UVS/PS/EM/950 98520 M154/O 28500
27000 22500 20000+ 5000 90+ Clear BU±15° B 6 320W/BU/ED37/PS 20
MP 350W/BU/ED28/UVS/PS/EM/950 33149 M131/O 30500
29000 24000 20000+ 5000 90+ Clear BU±15° A 12 350W/BU/ED28/PS 25
MP 350W/BU/UVS/PS/EM/950
51628 M131/O 30500
29000 24000 20000+ 5000 90+ Clear BU±15° B 6 350W/BU/ED37/PS 25
MP 350W/C/BU/UVS/PS/EM/950
38197 M131/O 28500
27000 22500 20000+ 5000 90+Coated BU±15° B 6 350W/C/BU/ED37/PS 25
MP 400W/BU/ED28/UVS/PS/EM/950 72315 M155/O 36000
34500 28500 20000+ 5000 90+ Clear BU±15° A 12 400W/BU/ED28/PS 25
MP 400W/BU/UVS/PS/EM/950
57129 M155/O 36000
34500 28500 20000+ 5000 90+ Clear BU±15° B 6 400W/BU/ED37/PS 25
MP 400W/C/BU/UVS/PS/EM/950
89410 M155/O 34000
32500 27000 20000+ 5000 90+Coated BU±15° B 6 400W/C/BU/ED37/PS 25
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
B
C
BT37
ED28
A
ED37
Notes: All lamps have a light loss factor (LLF) at 8000 hours of 0.9
1 Initial Outdoor Nighttime Lumens = Effective lumens multiplier relative to 4K = 1.27
2 Initial Indoor Visual Task Lumens = Effective lumens multiplier relative to 4K = 1.21
3 A life rating of 20,000++ hours means that at least 80% of the lamps initially installed will still be operating after 20,000 hours.
4 A life rating of 20,000+ hours means that at least 70% of the lamps initially installed will still be operating after 20,000 hours.
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
16
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
®
Natural White Ballasts
HIGH CRI
AND
H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
ELECTRONIC BALLAST Housings 60Hz Ventronic™
Product Number
OPE320HF208-277-(X)
Voltage
208-277
Input Voltage
188-305
OPE350HF208-277-(X)
208-277
188-305
375
375/(.92*Vline)
OPE400HF208-277-(X)
208-277
188-305
430
430/(.92*Vline)
277
249-305
465
465/(.92*Vline)
OPE450HF277-(X)
Input Watts Maximum Line Current ANSI Code
342
342/(.92*Vline)
M154
Fig.
A
Tot. Wt. (lbs)
15
EMI
FCC Part 18
M131
A
15
FCC Part 18
M155
A
15
FCC Part 18
M144
A
15
FCC Part 18
Wattage
250
Input
Voltage
277
Product
No.
V90U8421
ANSI Circuit Input
Code Type Watts
M153 Reactor 275
Max.
Line
Current
1.35
UL
Total
Max.
Coil Rise Wiring
Dimensions Wt. Capacitor Cap. Cap. Ign. Dist.
Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1 1.25 3.4 6 13/280 A1 Dry D 5
250 120/208/240/277 V90D8411
M153
CWA 285 2.45/1.45/1.25/1.10 A/A/A/A E
2
250
120/277/347
M153
CWA 288
2.50/1.10/0.90
B/A/B
K
2 1.55
3.5 10 15/400 A13 Dry D 2
250
480/120T
V90Y8410T M153
CWA 288
0.60
A
S1
2 1.55
3.5 10 15/400 A13 Dry D 2
250
480/120T
V90Y8411T
M153
CWA 288
0.60
A
S1
2
2
3.5 10 16/400
320
277
V90U7421
M154 Reactor 349
1.70
A
B1
1
1.5
V90J8410
2
3.5 10 16/400
3.6
Dry D 2
Dry D 2
7 16/280 A7 Dry D 2
M154
CWA 365 3.15/1.85/1.60/1.40 A/A/A/A E
2
2
4.1 11.5 22/330 A2 Dry D 2
320 120/208/240/277 V90D7413
M154
CWA 365 3.15/1.85/1.60/1.40 A/A/A/A E
2
2
4.1 11.5 22/330 A2 Dry D 2
320 120/208/240/277 V90D7430
M154 HX-HPF 360 4.80/2.85/2.45/2.10 B/C/C/C Y
2
1.8
3.7 11 20/280 A7 Dry D 2
320
120/277/347
M154
2
1.9
3.75 10.5 22/330 A2 Dry D 2
320
120/277/347
2
1.8
3.9 10.5 20/280 A7 Dry D 2
320
480/120T
CWA 368
0.80
A
S1
2
2
3.75 10.5 22/330 A2 Dry D 2
320
480/120T
V90Y7430T
M154 HX-HPF 370
1.20
D
W1
2
1.8
3.9 10.5 20/290 A7 Dry D 2
350
277
V90U7521
M131 Reactor 380
1.90
B
B1
1
1.8
3.6 7.4 18/280 A7 Dry D 2
CWA 368
3.20/1.40/1.15
B/C/C
V90J7430
M154 HX-HPF 365
5.25/2.25/1.70
D/D/D A1
V90Y7412T
M154
350 120/208/240/277 V90D7512
M131
350 120/208/240/277 V90D7530
350
120/277/347
350
120/277/347
350
480/120T
CWA 400
350
480/120T
V90Y7530T
400
277
V90U7621
V90J7512
K
CWA 400 3.60/2.10/1.80/1.55 B/C/C/C E
2 1.92
3.8 10.5 24/330 A2 Dry D 2
M131 HX-HPF 395 5.00/2.55/2.50/2.15 B/A/C/C Y
2
1.8
3.7 11 21.5/280 A7 Dry D 2
M131
2 1.92
3.8 10.5 24/330 A2 Dry D 2
CWA 400
3.50/1.55/1.20
B/C/C
K
V90J7530
M131 HX-HPF 395
5.10/2.15/1.75
C/C/C
A1
2
1.8
3.9 10.521.5/290 A7 Dry D 2
V90Y7512T
M131
0.90
D
S1
2 2.02
3.9 11.2 24/330 A2 Dry D 2
M131 HX-HPF 400
1.35
D
W1
2
3.9 10.521.5/290 A7 Dry D 2
M155 Reactor 435
2.10
C
B1
1 1.65
3.7
3.9 10.7 26/330 A3 Dry D 2
1.8
M155
CWA 450 4.00/2.30/2.00/1.75 C/C/C/C E
2
400
120/277/347
V90J7612
M155
CWA 451
4.00/1.75/1.40
D/D/D
K
2 2.15
400
480/120T
V90Y7612T
M155
CWA 455
1.00
D
S1
2
2.2
4.1 12 26/330 A3 Dry D 2
775
480
V90Y9610T M181
CWA 855
1.85
D
S1
3
2.8
4.95 21 22/490 B12 Oil
F 10
CWA 845 7.45/4.50/3.75/3.25 B/D/B/C E
3
2.8
4.95 18.5 22/500 B12 Oil
F 10
M181
Ballast Options
OPE
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
= HIDirect’s greener, energy-efficient (88%)
ballast: compliant with California Title 20 and federal
Energy Independence & Security Act of 2007
10.1
12.0
9.6
10.0
14.2
7.6
Weight = 15 lbs.
Width = 12”
Length = 10.1”
Height = 14.2”
3.75"
(95 mm)
3.30"
(84 mm)
4.05"
(103mm)
A
3 4x6 Core
2 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
B
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
CWA
4.50"
(114mm)
HX & CWA
REACTOR
1 33/4 x 41/2 Core
The Illuminating Engineering
Society was formed in 1906
4 11.3 26/330 A3 Dry D 2
Notes for electronic ballast housings are on page 42
A
Fun Facts
7 20/280 A7 Dry D 2
400 120/208/240/277 V90D7612
775 120/208/240/277 V90D9610
2
UNI-FORM®
Systems
320 120/208/240/277 V90D7412
V90J7411
Natural
White®
MAGNETIC BALLASTS 60Hz
6.00"
(152 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
3.87"
(98 mm)
4.375"
(111 mm)
5.375"(136 mm)
A B
A B
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
17
Natural White
HIGH CRI
AND
H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Natural White Spectrum
100
90
80
70
Relative Power (%)
®
60
50
40
30
Human Eye Sensitivity
What Are Scotopic Lumens?
The sensitivity of the human eye to different colors of light
at various light levels determines the true, or effective,
lumen output of a lamp. The eye responds to color
depending upon the amount of light available.
Nighttime Observations
20
Lumens are the standard measure of light output, but light
is actually defined as energy evaluated by the eye.
Conventional lumen measurements define the light output
response of a person only during high light levels (called
photopic light), typical of daylight and interior lighting.
The light meter measures photopic light as seen by the
central region of the eye.
10
0
393
443
493
543
593
643
693
743
Daylight Spectrum
100
90
80
70
Relative Power (%)
60
50
40
When light levels are very low, like starlight, the viewing
conditions are referred to as “scotopic.” Under these
conditions, the eye’s visual response changes
dramatically. Sensitivity to yellow and red light is greatly
reduced, while response to blue light is vastly increased.
If lamp lumens under scotopic viewing conditions have
been determined using photopic measuring devices, the
lumen value does not accurately measure the true amount
of light as perceived by the human eye.
30
20
10
0
393
443
493
543
593
643
693
743
Benefits
• 90% Lumen Maintenance
(0.90 Light Loss Factor)
• High CRI Lighting (Color
Rendering Index) 90+
• The Color of Natural
Sunlight: 5000K
Conventionally Measured
Outdoor Nighttime Lumens
(Photopic Lumens)
(Effective Lumens) (S/P)
Lumen Maintenance Comparison
Daytime Observations
Lamps with high scotopic content and high S/P ratios,
such as HIDirect’s Natural White® lamps, also improve the
ability to see indoors. Human studies have shown that the
S/P values, though previously applicable to only
nighttime conditions, can be used to describe the
“effective lumens” of indoor lighting as well. For example,
if two identical objects in 2 different rooms are lighted
separately with 4000K and 5000K lamps to equal
photopic luminance, the 5000K room will appear 21%
brighter (2.1/1.65)0.78.
Indoor Visual Task Lumens
1
(Effective Lumens) (S/P)
Lumen Maintenance Comparison
40,000
40,000
35,000
35,000
35,000
Natural White®
400W
Lamp Lumens
30,000
25,000
20,000
Standard
Probe Start 400W
15,000
10,000
20,000
Standard
Probe Start 400W
Visual
Brightness
10,000
5,000
10,000
15,000
20,000
Hours of Operation
Ceramic metal halide
4000K; 90 CRI
Natural White®
400W
30,000
Natural White®
400W
MP 40
25,000
15,000
0.78
Lumen Maintenance Comparison
40,000
30,000
Lamp Lumens
UNI-FORM®
Systems
Wavelength (nm)
Lamp Lumens
Natural
White®
Wavelength (nm)
Published lumen ratings are based on the “photopic”
lumen (“P”), or light measurement based on daytime
observations. Lumen measurements, corrected for
nighttime vision, are known as “scotopic” lumens (“S”).
The ratio of light measured by the 2 methods is called the
“S/P ratio”. The S/P ratio for white-blue (5000K
daylight) light sources is 2.1. At 4000K the ratio is 1.65,
and for HPS lamps the ratio is 0.64. As a result, 4000K
light sources are at least twice as effective for viewing at
night compared to HPS sources at the same photopic
luminance. 5000K light sources are at least three times
as effective.
25,000
20,000
Visual
Brightness
Standard
Probe Start 400W
15,000
10,000
5,000
10,000
15,000
20,000
5,000
Hours of Operation
Uni-Form Natural White®
5000K; 90+ CRI
10,000
15,000
20,000
Hours of Operation
Compact Fluorescent
3500K; 80 CRI
18
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Horizontal Pulse Start
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Performance is Everything
For lighting applications, performance is everything. It is
important that lighting fixtures provide top performance
in terms of heat management, optics and appearance.
The lamp and ballast are expected to provide uniform,
bright light as well as great lumen maintenance and long
life.
There are several types of burn positions posted by all
manufacturers. First, there is the Universal or “U”. There
is the Vertical or “V” and the Base Up or ”BU”. Lastly, we
have the Horizontal or “HOR”. Most horizontal lighting
applications sacrifice light and life with standard choices
in lamps.
Benefits
Life
The walls of the arc tube are substantially thickened with
quartz material. This results in less heating of the upper
side of the arc tube, which in turn results in longer overall
lamp life.
Positions of
Operation
Lumens
The Uni-Form arc tube shape has been modified to offer
better lumens. The chemistry of the metal halide arc tube
has been changed to produce the lumens that equal the
typical V or BU versions of the lamp. This also has
resulted in greater mean lumens of this product line.
HIDirect offers the horizontal pulse start lamp line that
now offers long life and high lumens based on a better
arc tube. This product line eliminates the problems
associated with the POM base lamp and socket and is
offered in a variety of jacket sizes and wattages.
Universal
(U)
Any Position
Application Targets
HIDirect’s horizontal pulse start (H75) series is targeted at
the mid-range wattages as well as the enclosed fixture.
This series of lamps is perfect for parking garages, car
dealerships, site lighting, wall washes, gas station
canopies, area lighting and parking lot lighting.
15° 15°
UNI-FORM®
Systems
HIDirect’s Horizontal Pulse Start systems is unique simply
because of the Uni-Form® formed body arc tube.
Understanding the practical need to remove the POM
base and socket requirement from horizontally operating
lamps, HIDirect found a way to keep the electrodes at the
center of the arc tube at all times, so the install positioning
has now become irrelevant.
HORIZONTAL OPERATION
Horizontal
PS Lamps
Horizontal +/- 75° (H75)
FOR
• Longer life compared to both universal and
HOR lamps in horizontal operation, and higher
lumen output
• No POM socket required
• Variety of outer jacket shapes and sizes for
full cut-off fixtures
Features
Vertical ±15°
(V)
• Thicker wall of the lamp arc tube
• Better distribution of the halides in the arc stream
75°
75°
Horizontal ±75°
(H75)
Leadership
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
19
Horizontal Pulse Start
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
FOR
HORIZONTAL OPERATION
Enclosed Rated LAMPS ANSI Type-E Mogul Base
Product
No.
70764
ANSI
Code
M136/E
Initial Lumens
Lumens Per Watt
19000
95
Mean
Lumens
15200
Avg. Life
Hours
15000
CCT Warm-UpRestrike
(K) (Min) (Min) CRI
4000 1-2 2-4 68
Oper.
Case
Finish
Pos.
Fig. Qty
Clear HOR±75° A 12
250
MS 250W/H75/PS/740
81054
M153/E
22000
88
17600
15000
4000 2-3
3-5
68
Clear HOR±75° D
12
250
MS 250W/H75/T15/PS/740
57625
M153/E
22000
88
17600
15000
4000 2-3
3-5
68
Clear HOR±75° B
12
320
MS 320W/H75/ED28/PS/740
47549
M154/E
30000
94
24000
20000+ 4000 2-3
4-6
68
Clear HOR±75° D
12
320
MS 320W/H75/T15/L/PS/740
79710
M154/E
30000
94
24000
20000+ 4000 2-3
4-6
68
Clear HOR±75° C
12
320
MS 320W/H75/T15/S/PS/740
57626
M154/E
30000
94
24000
20000+ 4000 2-3
4-6
68
Clear HOR±75° B
12
Applications
320
MS 320W/C/H75/ED28/PS/737 12758
M154/E
27000
84
21000
20000+ 3700 2-3
4-6
70 Coated HOR±75° D
12
Indoor or Outdoor
350
MS 350W/C/H75/PS/737
M131/E
31000
89
25000
20000+ 3700 2-3
4-6
70 Coated HOR±75° E
6
• Gas station canopies
350
MS 350W/H75/ED28/PS/740
46959
M131/E
33000
94
26000
20000+ 4000 2-3
4-6
68
Clear HOR±75° D
12
• Parking lots
350
MS 350W/H75/T15/PS/740
93749
M131/E
33000
94
26000
20000+ 4000 2-3
4-6
68
12
• Floodlighting
400
MS 400W/H75/PS/740
58788
M155/E
40000
100
32000
20000+ 4000 2-3
4-6
68
• Site lighting
400
MS 400W/H75/ED28/PS/740
40124
M155/E
40000
100
32000
20000+ 4000 2-3
4-6
68
Clear HOR±75° C
Clear HOR±75° E
Clear HOR±75° D
12
• Security lighting
400
MS 400W/C/H75/ED28/PS/737 55459
M155/E
38000
95
30000
20000+ 3700 2-3
4-6
70 Coated HOR±75° D
12
• Wall wash
64866
6
Note: 20,000+ hours means that at least 70% of the lamps initially installed will still be operating after 20,000 hours.
• Billboard lighting
• Indirect lighting
A
B
C
D
T15
T15
ED28
• Area lighting
T15
Dia. = 1 7⁄8” (46mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 1 7⁄8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E39
Dia. = 1 7⁄8” (46mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
E
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
42
20
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
ED37
UNI-FORM®
Systems
Horizontal
PS Lamps
Lamp
Watts Description
200 MS 200W/H75/T15/PS/740
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Uni-Form Systems
®
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Benefits of Uni-Form Systems
• Open-rated lamps (ANSI Type-O)
Compared to standard probe start metal halide:
- No luminaire lens required, delivers more light
• Longer life - up to 50% longer
- Operational 24/7 - no shut-off required
• Energy savings - more system lumens per watt means
more light for less energy
- Blocks nearly all damaging ultraviolet light with
UV Shield® technology
• Improved color uniformity - for minimal color
variation from lamp to lamp
- Meets 2005 National Electric Code® criteria for
open fixtures
• Faster warm-up and restrike - one third the time
• 70% survival at end of rated life - a 40% improvement
over standard probe start metal halide - on electronic
ballasts, acheive 80% survival at end of rated life
• Pleasant environment and better system performance
thanks to quiet, cool-running Opti-Wave® magentic
ballasts or Ventronic™ electronic ballasts
• Fewer lamp failures and less breakage in shipping
because of patented stronger weldless mount
Greener Ballasts
For more information about
this legislation, visit our
website.
Leadership
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
21
UNI-FORM®
Systems
HIDirect supports the green
energy
initiatives
of
California Title 20 and the
Energy Independence &
Security Act of 2007, which
mandate that metal halide
fixtures manufactured in
2009 must contain pulse start
ballasts that are at least 88%
efficient. We agree with the
need to move away from less
energy efficient standard
probe-start technology and
strongly recommend that
more efficient and “green”
pulse start technology be
embraced by all of our
customers immediately. Our
compliant ballasts have been
designated by the
green
leaf by the product number.
50 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS ANSI Type-O M110/O Medium Base featuring UV Shield®
Lamp
Description
MP 50W/U/UVS/PS
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
32100 3200V/2900H 64V/58H 2100V/1900H 10000V/7500H 4000 1-2
2-4 65 Clear U B 12
MP 50W/C/U/UVS/PS
30041 3000V/2700H 60V/54H 2000V/1800H 10000V/7500H 3700
1-2
2-4 70 Coated
U
MP 50W/U/UVS/PS/3K
10226 3200V/2900H 64V/58H 2100V/1900H 10000V/7500H 3200
1-2
2-4 65 Clear
U
B 12
MP 50W/C/U/UVS/PS/3K
10381 3000V/2700H 60V/54H 2000V/1800H 10000V/7500H 3200
1-2
2-4 70 Coated
U
B 12
B 12
Enclosed Rated LAMPS ANSI Type-E M110/E Medium Base
Applications
• Landscape Lighting
• Downlighting - Low Ceiling
• Sconce Lighting
Lamp
Description
MH 50W/U/PS
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
52312 3400V/3100H 68V/62H 2200V/2000H 10000V/7500H 4000 1-2
1-2 65 Clear U A 12
MH 50W/C/U/PS
13093 3200V/2900H 64V/58H 2100V/1900H 10000V/7500H 3700
1-2
1-2 70 Coated
U
A 12
UNI-FORM®
Systems
MAGNETIC BALLASTS 60Hz ANSI M110
Input
Voltage
120/208/240/277
Product
Circuit Input
Max. Line
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
No.
Type Watts
Current
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
V90D5731 HX-HPF 68 1.20/.065/0.60/0.50 A/A/A/A
Y
1 1.05 2.45 3.5 6/280 A5 Dry D 2
120/277
V90H5731 HX-HPF
68
1.20/0.50
A/A
Q1
1
1.05
2.1
3.5
6/280
A5 Dry D
2
120/277/347
V90J5731 HX-HPF
72
1.20/0.50/0.40
A/A/A
A1
1
1.05
2.45
3.3
6/280
A5 Dry D
2
Did you know…
Every time you turn on a light
switch, 72% of the energy
comes from coal.
B
EDX17
ED17
A
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Narrow Neck
Ballast Options
HX
1 3x4 Core
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
22
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
70 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O M98/O
Shield®
Lamp
Description
MP 70W/U/UVS/PS
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
40389 5300V/4800H 76V/69H 3400V/3100H 15000V/11250H 4000 1-2
2-4 65 Clear U B 12
MP 70W/C/U/UVS/PS
67115 5000V/4500H 71V/64H 3300V/3000H 15000V/11250H 3700
1-2
2-4 70 Coated
U
MP 70W/U/UVS/PS/3K
45424 5300V/4800H 76V/69H 3400V/3100H 15000V/11250H 3200
1-2
2-4 65 Clear
U
B 12
MP 70W/C/U/UVS/PS/3K
14611 5000V/4500H 71V/64H 3300V/3000H 15000V/11250H 3200
1-2
2-4 70 Coated
U
B 12
MP 70W/C/U/ED28/UVS/PS/3K 22466 5000V/4500H 71V/64H 3300V/3000H 15000V/11250H 3200
1-2
2-4 70 Coated
U
D 12
B 12
Enclosed Rated LAMPS ANSI Type-E M98/E
Applications
Lamp
Description
MH 70W/U/PS
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
78138 5600V/5000H 80V/71H 3600V/3300H 15000V/11250H 4000 1-2
1-2 65 Clear U A 12
• Security Lighting
• Signage Lighting
• Floodlighting
MH 70W/C/U/PS
12180 5300V/4800H 76V/69H 3400V/3100H 15000V/11250H 3700
1-2
1-2 70 Coated
U
A 12
MH 70W/U/ED28/PS
16017 5600V/5000H 80V/71H 3600V/3300H 15000V/11250H 4000
1-2
1-2 65 Clear
U
C 12
MAGNETIC BALLASTS 60Hz ANSI M98
Product
Circuit Input
Max. Line
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
No.
Type Watts
Current
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
V90D5832 HX-HPF 90 1.70/0.95/0.85/0.70 A/A/A/A
Y
1 1.45 2.85 4.9 8/280 A5 Dry D 2
120/208/240/277
V90D5833 HX-HPF
88 1.65/0.95/0.80/0.70 A/A/A/A
Y
1
1.45
2.85
4.6
8/280
A5 Dry D
2
120/277
V90H5832 HX-HPF
90
A/A
Q1
1
1.45
2.85
4.9
8/280
A5 Dry D
2
120/277
V90H5833 HX-HPF
88
1.65/0.70
A/A
Q1
1
1.45
2.85
4.6
8/280
A5 Dry D
2
120/277/347
V90J5832 HX-HPF
90
1.70/0.70/0.60
A/A/A
A1
1
1.45
2.85
4.9
8/280
A5 Dry D
2
1.70/0.70
UNI-FORM®
Systems
Input
Voltage
120/208/240/277
Fun Facts
German inventor Freidrich
Winzer (Winsor) was the first
person to patent coal gas
lighting in 1804.
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Narrow Neck
HX
2.44"
(62 mm)
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Ballast Options
1 3x4 Core
3.94" (100mm)
D
ED28
EDX17
C
ED28
B
ED17
A
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
23
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
100 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Shield®
Lamp
Description
MP 100W/U/UVS/PS
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
96267 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 4000 1-2
3-5 65 Clear U B 12
MP 100W/C/U/UVS/PS
11278 8100V/7300H 81V/73H 5300V/4800H 15000V/11250H 3700
1-2
3-5 70 Coated
U
MP 100W/U/UVS/PS/3K
96770 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 3200
1-2
3-5 65 Clear
U
B 12
MP 100W/C/U/UVS/PS/3K
11245 8100V/7300H 81V/73H 5300V/4800H 15000V/11250H 3200
1-2
3-5 70 Coated
U
B 12
MP 100W/C/U/ED28/UVS/PS/3K 22145 8100V/7300H 81V/73H 5300V/4800H 15000V/11250H 3200
1-2
3-5 70 Coated
U
D 12
B 12
Applications
Enclosed Rated LAMPS ANSI Type-E M90/E
• Hazardous Location
Lighting
• Bollard Lighting
• Security Lighting
Lamp
Description
MH 100W/U/PS
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
27266 9000V/8100H 90V/81H 5900V/5300H 15000V/11250H 4000 1-2
2-4 65 Clear U A 12
MH 100W/C/U/PS
15823 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 3700
1-2
2-4 70 Coated
U
A 12
MH 100W/U/ED28/PS
67868 9000V/8100H 90V/81H 5900V/5300H 15000V/11250H 4000
1-2
2-4 65 Clear
U
C 12
MH 100W/C/U/ED28/PS
79986 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 3700
1-2
2-4 70 Coated
U
C 12
MAGNETIC BALLASTS 60Hz ANSI M90
120/208/240/277
V90D5932 HX-HPF 125 2.60/1.50/1.30/1.15 A/A/A/A
Y
2
1.7
3.1
5.3
12/280 A6 Dry D
2
120/277
V90H5932 HX-HPF 125
2.60/1.15
A/A
Q1
2
1.7
3.1
5.8
12/280 A6 Dry D
2
120/277/347
V90J5932 HX-HPF 126
2.60/1.15/0.90
A/A/A
A1
2
1.7
3.1
5.3
12/280 A6 Dry D
5
B
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Narrow Neck
1 7/8 in Core
2.625"
(67mm)
D
ED28
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Ballast Options
2 3x4 Core
HOLES CLEARED
FOR # 6 BOLTS
2.188"
(56 mm)
1.75"
(45 mm)
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1 1.65 2.9 2.85 10/280 A6 Dry D 2
C
EDX17
ED17
A
Max. Line
Current
1.05
ED28
Around 70,000 B.C. whole
rocks, shells, or other natural
found objects were filled with
moss or similar material that
was soaked in animal fat and
then ignited and used as a
source of light.
Product
Circuit Input
No.
Type Watts
V90U5920 Reactor 118
2.189"
(56mm)
HX
Fun Facts
Input
Voltage
277
REACTOR
UNI-FORM®
Systems
Open Rated LAMPS ANSI Type-O M90/O
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
24
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
125 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O M150/O
Avg. Life CCT Warm-Up Restrike
Hours
(K) (Min) (Min) CRI
15000 4000 1-2
3-5
65
Shield®
Lamp
Description
MP 125W/BU/UVS/PS
Product
No.
13341
Initial Lumens Mean
Lumens Per Watt Lumens
11400
91
8000
Oper.
Finish
Pos.
Clear BU±15°
Case
Fig. Qty
B 12
MP 125W/C/BU/UVS/PS
43319
10800
86
7600
15000
3700
1-2
3-5
70
Coated BU±15°
B
12
MP 125W/V/ED28/UVS/PS
25813
11400
91
8000
15000
4000
1-2
3-5
65
Clear
D
12
V±15°
Enclosed Rated LAMPS ANSI Type-E M150/E
Lamp
Description
MH 125W/HBU/PS
Product
No.
76602
Initial Lumens Mean Avg. Life CCT Warm-Up Restrike
Lumens Per Watt Lumens
Hours
(K) (Min) (Min) CRI
12000BU 96BU 8400BU 15000BU 4000 1-2
2-4
65
Oper.
Finish
Pos.
Clear BU±90°
Case
Fig. Qty
A 12
MH 125W/C/HBU/PS
35638
11400BU 91BU
8000BU 15000BU 3700
1-2
2-4
70
Coated BU±90°
A
12
MH 125W/HBU/ED28/PS
61914
12000BU 96BU
8400BU 15000BU 4000
1-2
2-4
65
Clear BU±90°
C
12
Applications
• Parking Garage
• Energy Saving Retrofits
MAGNETIC BALLASTS 60Hz ANSI M150
Input
Voltage
277
Product
Circuit Input
No.
Type Watts
V90U8820 Reactor 141
Max. Line
Current
0.85
120/208/240/277
V90D8811
CWA
150 1.25/0.75/0.65/0.55 A/A/A/A
E
2
1.7
3.15
5.4
12/280 A6 Dry D
2
120/277
V90H8811
CWA
150
1.25/0.55
A/A
T1
2
1.7
3.15
5.4
12/280 A6 Dry D
2
120/277/347
V90J8811
CWA
150
1.25/0.55/0.45
A/A/A
K
2
1.7
3.15
5.4
12/280 A6 Dry D
2
Think green. Switch to 125W
ThinkGreen
Replace
• Save 60 system watts per
luminaire
• 96 lumens per watt
• Obtain 33% more lumen
output at 10,000 hours
Standard Probe Start 175 Watt with
Uni-Form
®
Pulse Start
• 50% Longer lamp life
125 Watt
• Available in dual and
quad tap CWA
Lumen Maintenance Comparison
C
D
EDX17
ED28
ED28
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Narrow Neck
2.625"
(67mm)
2.188"
(56 mm)
1.75"
(45 mm)
2.189"
(56mm)
A B
Uni-Form®
125W
320W
12,000
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
8,000
Standard
Probe Start
400W
175W
(Rated Lamp Life
10,000 Hours)
4,000
5,000
10,000
15,000
Hours of Operation
Ballast Options
2 3x4 Core
HOLES CLEARED
FOR # 6 BOLTS
CWA
REACTOR
1 7/8 in Core
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Lamp Lumens
B
ED17
16,000
A
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
25
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
UNI-FORM®
Systems
HIDirect’s 125W Uni-Form®
pulse start metal halide system
is the perfect green alternative
to the 175W standard probe
start. The 125W is a great
solution to the California Title
20 and Energy Independence
and Security Act of 2007.
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1 1.5 2.65 2.5 8/280 A5 Dry D 2
150 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O M102/O
Lamp
Description
MP 150W/U/UVS/PS/740
Applications
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
22455 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 4000 1-2
3-5 68 Clear U B 12
MP 150W/C/U/UVS/PS/737 22888 12600V/11300H 84V/75H 9500V/8500H 15000V/11250H 3700
1-2
3-5 70 Coated
U
MP 150W/U/UVS/PS/732
22522 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 3200
1-2
3-5 68 Clear
U
B 12
MP 150W/C/U/UVS/PS/732 80039 12600V/11300H 84V/75H 9500V/8500H 15000V/11250H 3200
1-2
3-5 70 Coated
U
B 12
B 12
MP 150W/U/ED28/UVS/PS/740 58963 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 4000
1-2
3-5 68 Clear
U
D 12
MP 150W/C/U/ED28/UVS/PS/737 32147 12600V/11300H 84V/75H 9500V/8500H 15000V/11250H 3700
1-2
3-5 70 Coated
U
D 12
Enclosed Rated LAMPS ANSI Type-E M102/E
Parking Garage
Security Lighting
Retail Lighting
Airport Lighting
Residential Roadways
Lamp
Description
MH 150W/U/PS/740
Product
Initial
Lumens
Mean
Avg. Life
CCT Warm-Up Restrike
Oper.
Case
No.
Lumens
Per Watt
Lumens
Hours
(K) (Min) (Min) CRI Finish Pos. Fig. Qty
99584 14000V/12600H 93V/84H 10500V/9500H 15000V/11250H 4000 1-2
2-4 68 Clear U A 12
MH 150W/C/U/PS/737
94986 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 3700
1-2
2-4 70 Coated
U
MH 150W/U/ED28/PS/740
13556 14000V/12600H 93V/84H 10500V/9500H 15000V/11250H 4000
1-2
2-4 68 Clear
U
C 12
MH 150W/C/U/ED28/PS/737 21344 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 3700
1-2
2-4 70 Coated
U
C 12
A 12
MAGNETIC BALLASTS 60Hz ANSI M102
Input
Voltage
277
Product
Circuit Input
No.
Type Watts
V90U7120 Reactor 170
Fun Facts
277
V90U7121
B1
1
2.5
3.9
4.3
14/280 A1 Dry D
2
1875: Henry Woodward
patents the electric light bulb.
120/208/240/277
V90D7110
190 1.70/1.00/0.85/0.75 C/C/C/D
E
2
2.5
3.9
8.2
16/330 A7 Dry D
2
120/208/240/277
V90D7130 HX-HPF 185 3.60/2.20/1.80/1.55 B/D/C/C
Y
2
2.25
3.9
7.1
16/280 A7 Dry D
2
120/277
V90H7130 HX-HPF 185
Q1
2
2.25
3.9
7.1
16/280 A7 Dry D
2
120/277/347
V90J7110
190
1.65/0.70/0.55
D/C/C
K
2
2.75
4.1
8.6
16/330 A7 Dry D
2
120/277/347
V90J7130 HX-HPF 185
3.65/1.55/1.25
C/D/D
A1
2
2.25
3.9
7.1
16/280 A7 Dry D
2
480/120T
V90Y7110T CWA 190
0.40
C
S1 2 2.75 4.1 8.6 16/330 A7 Dry D
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
2
Max. Line
Current
1.50
Reactor 170
CWA
CWA
D
ED28
ED28
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Narrow Neck
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Ballast Options
2.189"
(56mm)
A B
HX & CWA
2 3x4 Core
HOLES CLEARED
FOR # 6 BOLTS
2.188"
(56 mm)
1.75"
(45 mm)
B/C
C
1 7/8 in Core
2.625"
(67mm)
A
3.60/1.55
EDX17
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1 2.5 3.9 4.3 14/280 A1 Dry D 2
1.50
B
ED17
A
REACTOR
UNI-FORM®
Systems
•
•
•
•
•
Shield®
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
26
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
175 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O M152/O
Lamp
Description
MP 175W/BU/UVS/PS/740
Product
No.
69854
Initial Lumens
Lumens Per Watt
16000
91
Mean Avg. Life
Lumens Hours
12800 15000
Shield®
CCT Warm-Up Restrike
Oper.
Case
(K)
(Min)
(Min) CRI Finish Pos. Fig. Qty
4000
1-2
3-5 68 Clear BU±15° C
12
Enclosed Rated LAMPS ANSI Type-E M152/E
Lamp
Description
MS 175W/BU/MED/PS/740
Product
No.
16497
Initial Lumens Mean
Lumens Per Watt Lumens
17500
100
14000
Avg. Life CCT Warm-Up Restrike
Hours
(K) (Min) (Min) CRI
15000 4000 1-2
2-4
68
Oper.
Finish
Pos.
Clear BU±15°
Case
Fig. Qty
A 12
MS 175W/C/BU/MED/PS/737
34691
16600
95
13300
15000
3700
1-2
2-4
70
Coated BU±15°
A
12
MS 175W/BU/PS/740
68475
17500
100
14000
15000
4000
1-2
2-4
68
Clear BU±15°
B
12
MS 175W/C/BU/PS/737
68246
16600
95
13300
15000
3700
1-2
2-4
70
Coated BU±15°
B
12
MAGNETIC BALLASTS 60Hz ANSI M152
Input
Voltage
277
Product
No.
V90U7221
120/208/240/277
Circuit Input
Type Watts
Reactor 194
V90D7210
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1 0.85 2.9
4 10/280 A6 Dry D 2
CWA
208 1.90/1.05/0.95/0.80 B/C/A/A
E
2
2.63
4
CWA
A/A/A/A
E
2
3
4.3
8
12.5/330 A1 Dry D
10
120/277/347
V90J7210
CWA
208
1.90/0.80/0.65
B/B/B
K
2
2.63
4
8
12.5/330 A1 Dry D
10
480/120T
V90Y7210T
CWA
208
0.50
C
S1
2
2.63
4
8
12.5/330 A1 Dry D
10
A
E
2
3
4.3
480/120T
V90Y7211T
CWA
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
2.188"
(56 mm)
1.75"
(45 mm)
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Ballast Options
2 3x4 Core
HOLES CLEARED
FOR # 6 BOLTS
2.189"
(56mm)
A B
HX & CWA
REACTOR
1 7/8 in Core
2.625"
(67mm)
In 1792 William Murdoch
began experimenting with
gas lighting and probably
produced the first gas light in
that year.
C
ED28
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Fun Facts
ED28
B
ED17
A
• Parking Garage
• Canopy Lighting
• Lowbay Industrial Lighting
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
27
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
UNI-FORM®
Systems
120/208/240/277 V90D7211
Max. Line
Current
1.05
Applications
200 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O M136/O
Lamp
Description
MP 200W/V/UVS/PS/740
Product
No.
22147
Initial
Lumens
20000
Lumens
Per Watt
100
MP 200W/C/V/UVS/PS/737
59174
19000
MP 200W/C/V/UVS/PS/732
44872
19000
Shield®
Mean Avg. Life CCT Warm-Up Restrike
Lumens Hours
(K) (Min) (Min) CRI
16000 15000 4000 1-2
3-5
68
Oper.
Finish Pos.
Clear V±15°
Case
Fig. Qty
C 12
95
15200
15000
3700
1-2
3-5
70
Coated V±15°
C
12
95
15200
15000
3200
1-2
3-5
70
Coated V±15°
C
12
Enclosed Rated LAMPS ANSI Type-E M136/E
Applications
Energy Saving Retrofits
Parking Garage
Roadways
Site Lighting
Product
No.
60811
Initial Lumens Mean
Lumens Per Watt Lumens
21000
105
16800
Avg. Life CCT Warm-Up Restrike
Hours
(K) (Min) (Min) CRI
12000 4000 1-2
2-4
68
Oper.
Finish
Pos.
Clear BU±15°
Case
Fig. Qty
A 12
MS 200W/C/BU/MED/PS/737
60812
20000
100
16000
12000
3700
1-2
2-4
70
Coated BU±15°
A
MS 200W/V/PS/740
57739
21000
105
16800
15000
4000
1-2
2-4
68
Clear
V±15°
B
12
MS 200W/C/V/PS/737
70345
20000
100
16000
15000
3700
1-2
2-4
70
Coated V±15°
B
12
MS 200W/H75/T15/PS/740
70764
19000
95
15200
15000
4000
1-2
2-4
68
Clear HOR±75°
D
12
12
Benefits
MAGNETIC BALLASTS 60Hz ANSI M136
• 21,000 lumens!
Input
Voltage
277
Product
No.
V90U7321
120/208/240/277
V90D7330 HX-HPF 235 3.30/2.05/1.65/1.45 A/A/A/A
Y
2
2.25
3.9
7
16/290 A7 Dry D
2
• Highest wattage available
in an ED17 jacket
120/208/240/277
V90D7310
CWA
232 2.00/1.15/1.00/0.85 A/A/A/A
E
2
2.5
3.9
8
16/300 A7 Dry D
2
120/208/240/277 V90D7311
CWA
228 1.95/1.15/1.00/0.85 A/A/A/A
E
3
2
3.8
7.5
15/300
2
More light in a smaller lamp
offers designers better, more
cost-effective and energyefficient choices:
120/208/240/277 V90D7312
CWA
A/A/A/A
E
2
3
4.3
1. Achieve the same light
levels using fewer fixtures
Max. Line
Current
1.25
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1
1
2.9 4.5 12/280 A6 Dry D 5
D
120/277/347
V90J7330 HX-HPF 240
3.45/1.45/1.15
D/C/C
A1
2
2.45
3.9
7.5
16/290 A7 Dry D
2
120/277/347
V90J7310
2.00/0.85/0.70
A/A/A
K
2
2.5
3.9
8
16/300 A7 Dry D
2
480/120T
V90Y7330T HX-HPF 235
0.80
D
W1
2
2.45
3.9
8
16/280 A7 Dry D
2
480/120T
V90Y7310T
0.50
A
F
2
2.5
3.9
8
16/300 A7 Dry D
2
8
15/300
CWA
CWA
235
235
480/120T
V90Y7311T
CWA
A
F
3
2
3.8
480/120T
V90Y7312T
CWA
A
F
2
3
4.3
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
B
C
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
1 33/4 x 41/2 Core
4.50"
(114mm)
4.05"
(103mm)
A
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Dia. = 1 7/8” (46mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Ballast Options
2 3x4 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
D
T15
ED28
ED17
A
ED28
OR
2. Achieve increased light
levels using the same
number of fixtures
Circuit Input
Type Watts
Reactor 219
B
HX & CWA
• 50% longer life than 250W
and 175W standard probe
start systems
REACTOR
UNI-FORM®
Systems
•
•
•
•
Lamp
Description
MS 200W/BU/MED/PS/740
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
28
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
250 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O M153/O
Lamp
Description
MP 250W/BU/UVS/PS/740
Product
No.
64658
Initial Lumens Mean
Lumens Per Watt Lumens
23800
95
19000
MP 250W/C/BU/UVS/PS/737
32658
22600
90
18000
Avg. Life CCT Warm-Up Restrike
Hours
(K) (Min) (Min) CRI
15000 4000 2-3
4-6
68
15000
3700
2-3
4-6
70
Shield®
Oper.
Finish
Pos.
Clear BU±15°
Coated BU±15°
Case
Fig. Qty
B 12
B
12
Enclosed Rated LAMPS ANSI Type-E M153/E
Lamp
Description
MS 250W/V/PS/740
Product
No.
49621
Initial Lumens Mean
Lumens Per Watt Lumens
25000
100
20000
Avg. Life CCT Warm-Up Restrike
Hours
(K) (Min) (Min) CRI
15000 4000 2-3
3-5
68
MS 250W/C/V/PS/737
81365
23800
95
19000
15000
3700
2-3
3-5
70
Coated V±15°
A
12
MS 250W/H75/PS/740
81054
22000
88
17600
15000
4000
2-3
3-5
68
Clear HOR±75°
A
12
MS 250W/H75/T15/PS/740
57625
22000
88
17600
15000
4000
2-3
3-5
68
Clear HOR±75°
C
12
Finish
Clear
Oper.
Pos.
V±15°
Case
Fig. Qty
A 12
Applications
• Site Lighting
• Lowbay Industrial Lighting
MAGNETIC BALLASTS 60Hz ANSI M153
Product
No.
V90U8421
120/208/240/277
Circuit Input
Type Watts
Reactor 275
Max. Line
Current
1.35
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 1 1.25 3.4
6 13/280 A1 Dry D 5
V90D8410
CWA
288 2.50/1.45/1.25/1.10 B/B/A/A
E
2
1.55
3.5
10
15/400 A13 Dry D
2
120/208/240/277 V90D8411
CWA
285 2.45/1.45/1.25/1.10 A/A/A/A
E
2
2
3.5
10
16/400
Dry D
2
120/277/347
V90J8410
CWA
288
2.50/1.10/0.90
B/A/B
K
2
1.55
3.5
10
15/400 A13 Dry D
2
480/120T
V90Y8410T
CWA
288
0.60
A
S1
2
1.55
3.5
10
15/400 A13 Dry D
2
CWA
288
0.60
A
S1
2
2
3.5
10
16/400
2
480/120T
V90Y8411T
Dry D
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
B
HX & CWA
REACTOR
4.05"
(103mm)
A
Dia. = 1 7/8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E39
2 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
T15
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
1 33/4 x 41/2 Core
4.50"
(114mm)
In 1879 Thomas Edison and
Joseph
Wilson
Swan
patented the carbon-thread
incandescent lamp and in
1880 Edison produced a 16
watt lightbulb that lasted
1500 hours.
C
ED28
B
ED28
A
Fun Facts
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
29
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
UNI-FORM®
Systems
Input
Voltage
277
320 Watt Lamps
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield®
Lamp
Product
Description
No.
MP 320W/V/ED37/EL/UVS/PS/740 25984
Initial Lumens Mean Avg. Life CCT Warm-Up Restrike
Lumens Per Watt Lumens Hours** (K) (Min) (Min) CRI
31000
97
26000 20000++ 4000 2-3
5-8
68
Finish
Clear
MP 320W/C/V/ED37/EL/UVS/PS/73732409
29000
Coated V±15°
91
25000
20000++ 3700
2-3
5-8
70
Oper.
Pos.
V±15°
featuring UV
Open Rated LAMPS ANSI Type-O M154/O Mogul Base
Case
Fig. Qty
C
6
C
6
Shield®
Lamp
Product
Description
No.
MP 320W/BU/ED28/UVS/PS/740 10103
Initial Lumens Mean
Lumens Per Watt Lumens
31000
97
25000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
5-8
68
Oper.
Finish
Pos.
Clear BU±15°
Applications
MP 320W/C/BU/ED28/UVS/PS/737 10104
29000
91
23000
20000+ 3700
2-3
5-8
70
Coated BU±15°
B
•
•
•
•
MP 320W/BU/ED37/UVS/PS/740 21714
31000
97
25000
20000+ 4000
2-3
5-8
68
Clear BU±15°
D
6
MP 320W/C/BU/ED37/UVS/PS/737 32795
29000
91
23000
20000+ 3700
2-3
5-8
70
Coated BU±15°
D
6
MP 320W/C/BU/ED37/UVS/PS/732 66506
29000
91
23000
20000+ 3200
2-3
5-8
70
Coated BU±15°
D
6
Big Box Retail
Warehouse Lighting
Residential Roadways
Site Lighting
Case
Fig. Qty
B 12
12
Benefits
• 33,000 Initial Lumens
Lamp
Description
MS 320W/V/ED28/PS/740
Product
No.
59194
Initial Lumens Mean
Lumens Per Watt Lumens
33000
103
26000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
4-6
68
Finish
Clear
Oper.
Pos.
V±15°
Case
Fig. Qty
A 12
MS 320W/C/V/ED28/PS/737
77594
31000
97
25000
20000+ 3700
2-3
4-6
70
Coated V±15°
A
12
• 26,000 Mean Lumens
MS 320W/V/ED37/PS/740
52236
33000
103
26000
20000+ 4000
2-3
4-6
68
Clear
C
6
Compared to 400W
standard probe start system:
MS 320W/C/V/ED37/PS/737
67712
31000
97
25000
20000+ 3700
2-3
4-6
70
Coated V±15°
C
6
MS 320W/H75/ED28/PS/740
47549
30000
94
24000
20000+ 4000
2-3
4-6
68
Clear HOR±75°
A
12
• Save up to 106 system
watts per luminaire
MS 320W/C/H75/ED28/PS/737
12758
27000
84
21000
20000+ 3700
2-3
4-6
70
Coated HOR±75°
A
12
MS 320W/H75/T15/L/PS/740
79710
30000
94
24000
20000+ 4000
2-3
4-6
68
Clear HOR±75°
E
12
MS 320W/H75/T15/S/PS/740
57626
30000
94
24000
20000+ 4000
2-3
4-6
68
Clear HOR±75°
F
12
• Achieve 13% more lumen
output at 8,000 hours and
almost 30% more lumen
output at 20,000 hours
Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours.
**A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours.
• More Reliable: At end of
rated life 70% of the lamps
initially installed will be
operating; 80% survival on
electronic ballasts
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
ED37
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
F
T15
E
D
ED37
C
ED28
B
ED28
A
T15
UNI-FORM®
Systems
Enclosed Rated LAMPS ANSI Type-E M154/E Mogul Base
Dia. = 1 7⁄8” (46mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Dia. = 1 7/8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E39
30
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
V±15°
320 Watt Ballasts
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
ELECTRONIC BALLAST Housings 60Hz Ventronic™
Product Number
OPE320HF208-277-(X)
Voltage
208-277
Input Voltage
188-305
Input Watts Maximum Line Current ANSI Code
342
342/(.92*Vline)
M154
Fig.
1
Tot. Wt. (lbs)
15
EMI
FCC Part 18
MAGNETIC BALLASTS 60Hz ANSI M132/M154
Input
Voltage
277
Product
No.
V90U7421
120/208/240/277
V90D7411
Circuit Input
Type Watts
Reactor 349
Max. Line
Current
1.70
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
A
B1 2 1.5 3.6
7 16/280 A7 Dry D 2
CWA
368 3.20/1.80/1.60/1.40 B/B/B/B
E
3
1.85
3.65
22/330 A2 Dry D
2
120/208/240/277 V90D7412
CWA
365 3.15/1.85/1.60/1.40 A/A/A/A
E
3
2
4.1
11.5 22/330 A2 Dry D
2
120/208/240/277 V90D7413
CWA
365 3.15/1.85/1.60/1.40 A/A/A/A
E
3
2
4.1
11.5 22/330 A2 Dry D
2
HX-HPF 360 4.80/2.85/2.45/2.10 B/C/C/C
Y
3
1.8
3.7
20/280 A7 Dry D
2
3
1.9
3.75 10.5 22/330 A2 Dry D
2
120/208/240/277 V90D7430
120/277/347
V90J7411
120/277/347
V90J7430
480/120T
V90Y7411T
480/120T
V90Y7412T
480/120T
V90Y7430T
CWA
10
11
368
3.20/1.40/1.15
B/C/C
K
HX-HPF 365
5.25/2.25/1.70
D/D/D
A1
3
1.8
3.9
10.5 20/280 A7 Dry D
2
0.80
D
S1
3
1.9
3.75 10.5 22/330 A2 Dry D
2
3.75 10.5 22/330 A2 Dry D
2
3.9
2
CWA
368
CWA
368
0.80
A
S1
3
2
HX-HPF 370
1.20
D
W1
3
1.8
10.5 20/290 A7 Dry D
Applications
• Energy Saving Retrofits
• Security Lighting
• Parking Garage
ThinkChoices
HIDirect has the largest selection of systems to replace
standard probe start 400 Watt systems
HIDirect’s 320W Uni-Form®
pulse start metal halide system
is the perfect green alternative
to the 400W standard probe
start system. HIDirect has the
largest offering of 320W pulse
start systems, open or enclosed
fixture rated.
Lumen Maintenance Comparison
45,000
OPE
1
40,000
10.1
Lamp Lumens
12.0
35,000
30,000
9.6
10.0
Uni-Form®
320W
14.2
7.6
25,000
Weight = 15 lbs.
Width = 12”
Length = 10.1”
Height = 14.2”
20,000
Standard
Probe Start
400W
15,000
5,000
10,000
15,000
20,000
Hours of Operation
4.50"
(114mm)
3 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
4.05"
(103mm)
A
B
HX & CWA
REACTOR
2 33/4 x 41/2 Core
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
31
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
UNI-FORM®
Systems
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
350 Watt Lamps
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield®
Lamp
Description
MP 350W/V/EL/UVS/PS/740
Product
No.
44983
Initial Lumens Mean Avg. Life CCT Warm-Up Restrike
Lumens Per Watt Lumens Hours** (K) (Min) (Min) CRI
35000
100
30000 20000++ 4000 2-3
5-8
68
Finish
Clear
MP 350W/C/V/EL/UVS/PS/737
48952
33000
Coated V±15°
94
28000
20000++ 3700
2-3
5-8
70
Open Rated LAMPS ANSI Type-O M131/O Mogul Base
Applications
Big Box Retail
Warehouse Lighting
Residential Roadways
Site Lighting
Energy Saving Retrofits
UNI-FORM®
Systems
•
•
•
•
•
Oper.
Pos.
V±15°
Case
Fig. Qty
D 6
D
6
featuring UV
Shield®
Oper.
Pos.
V±15°
Case
Fig. Qty
D 6
Lamp
Description
MP 350W/V/UVS/PS/740
Product
No.
22149
Initial Lumens Mean
Lumens Per Watt Lumens
35000
100
28000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
5-8
68
Finish
Clear
MP 350W/C/V/UVS/PS/737
44097
33000
94
26000
20000+ 3700
2-3
5-8
70
Coated V±15°
D
MP 350W/C/V/UVS/PS/732
27845
33000
94
26000
20000+ 3200
2-3
5-8
70
Coated V±15°
D
6
MP 350W/V/ED28/UVS/PS/740
47887
35000
100
28000
20000+ 4000
2-3
5-8
68
Clear
V±15°
B
12
MP 350W/C/V/ED28/UVS/PS/737 55401
33000
94
26000
20000+ 3700
2-3
5-8
70
Coated V±15°
B
12
6
Enclosed Rated LAMPS ANSI Type-E M131/E Mogul Base
Lamp
Description
MS 350W/V/PS/740
Product
No.
98389
Initial Lumens Mean
Lumens Per Watt Lumens
37000
106
29000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
4-6
68
Finish
Clear
Oper.
Pos.
V±15°
MS 350W/C/V/PS/737
71329
35000
100
28000
20000+ 3700
2-3
4-6
70
Coated V±15°
C
6
MS 350W/V/ED28/PS/740
52980
37000
106
29000
20000+ 4000
2-3
4-6
68
Clear
A
12
MS 350W/C/H75/PS/737
64866
31000
89
25000
20000+ 3700
2-3
4-6
70
Coated HOR±75°
C
6
V±15°
Case
Fig. Qty
C
6
MS 350W/H75/ED28/PS/740
46959
33000
94
26000
20000+ 4000
2-3
4-6
68
Clear HOR±75°
A
12
MS 350W/H75/T15/PS/740
93749
33000
94
26000
20000+ 4000
2-3
4-6
68
Clear HOR±75°
E
12
Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours.
**A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours.
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
32
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
T15
E
ED37
D
ED37
C
ED28
B
ED28
A
Dia. = 1 7⁄8” (46mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
350 Watt Ballasts
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
ELECTRONIC BALLAST Housings 60Hz Ventronic™
Product Number
OPE350HF208-277-(X)
Voltage
208-277
Input Voltage
188-305
Input Watts Maximum Line Current ANSI Code
375
375/(.92*Vline)
M131
Fig.
1
Tot. Wt. (lbs)
15
EMI
FCC Part 18
MAGNETIC BALLASTS 60Hz ANSI M131
Input
Voltage
277
Product
No.
V90U7521
120/208/240/277 V90D7512
120/208/240/277 V90D7530
120/277/347
V90J7512
120/277/347
V90J7530
480/120T
V90Y7512T
480/120T
V90Y7530T
Circuit Input
Type Watts
Reactor 380
CWA
Max. Line
Current
1.90
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
B
B1 2 1.8 3.6 7.4 18/280 A7 Dry D 2
400 3.60/2.10/1.80/1.55 B/C/C/C
HX-HPF 395 5.00/2.55/2.50/2.15 B/A/C/C
E
3
1.92
3.8
10.5 24/330 A2 Dry D
2
Y
3
1.8
3.7
11 21.5/280 A7 Dry D
2
400
3.50/1.55/1.20
B/C/C
K
3
1.92
3.8
10.5 24/330 A2 Dry D
2
HX-HPF 395
5.10/2.15/1.75
C/C/C
A1
3
1.8
3.9
10.5 21.5/290 A7 Dry D
2
400
0.90
D
S1
3
2.02
3.9
11.2 24/330 A2 Dry D
2
HX-HPF 400
1.35
D
W1
3
1.8
3.9
10.5 21.5/290 A7 Dry D
2
CWA
CWA
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
Applications
•
•
•
•
•
Big Box Retail
Warehouse Lighting
Residential Roadways
Site Lighting
Energy Saving Retrofits
UNI-FORM®
Systems
OPE
1
10.1
12.0
9.6
10.0
14.2
7.6
Weight = 15 lbs.
Width = 12”
Length = 10.1”
Height = 14.2”
4.50"
(114mm)
3 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
4.05"
(103mm)
A
B
HX & CWA
REACTOR
2 33/4 x 41/2 Core
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
33
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
400 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield®
Lamp
Description
MP 400W/V/EL/UVS/PS/740
Product
No.
56745
Initial Lumens Mean Avg. Life CCT Warm-Up Restrike
Lumens Per Watt Lumens Hours*** (K) (Min) (Min) CRI
41000
103
35000 20000++ 4000 2-3
5-8
68
Finish
Clear
MP 400W/C/V/EL/UVS/PS/737
78752
39000
Coated V±15°
98
33000
20000++ 3700
2-3
5-8
70
Oper.
Pos.
V±15°
Case
Fig. Qty
D 6
D
6
Open Rated LAMPS ANSI Type-O M155/O Mogul Base featuring UV Shield®
Applications
Highbay Industrial
Manufacturing Lighting
Site Lighting
Big Box Retail
Convention Centers
UNI-FORM®
Systems
•
•
•
•
•
Lamp
Description
MP 400W/V/UVS/PS/740
Product
No.
71642
Initial Lumens Mean
Lumens Per Watt Lumens
41000
103
33000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
5-8
68
MP 400W/C/V/UVS/PS/737
45541
39000
98
31000
20000+ 3700
2-3
5-8
70
MP 400W/V/ED28/UVS/PS/740
12445
41000
103
33000
20000+ 4000
2-3
5-8
68
Oper.
Pos.
V±15°
Coated V±15°
Clear V±15°
MP 400W/C/V/ED28/UVS/PS/737 88648
39000
98
31000
20000+ 3700
2-3
5-8
70
Coated V±15°
Finish
Clear
Case
Fig. Qty
D 6
D
6
B
12
B
12
Enclosed Rated LAMPS ANSI Type-E M155/E Mogul Base
Lamp
Description
MS 400W/V/PS/740
Product
No.
73531
MS 400W/C/V/PS/737
42401
MS 400W/V/ED28/PS/740
85260
Initial Lumens Mean Avg. Life CCT Warm-Up Restrike
Oper.
Lumens Per Watt Lumens Hours*
(K) (Min) (Min) CRI Finish
Pos.
44000
110
3500020000+/30000**4000 2-3
4-6
68 Clear V±15°
42000
105
3300020000+/30000**3700 2-3
4-6
70 Coated V±15°
44000
110
35000 20000+ 4000 2-3
4-6
68 Clear V±15°
MS 400W/C/V/ED28/PS/737
46416
42000
105
33000
20000+ 3700
2-3
4-6
70
MS 400W/H75/PS/740
58788
40000
100
32000
20000+ 4000
2-3
4-6
68
MS 400W/H75/ED28/PS/740
40124
40000
100
32000
20000+ 4000
2-3
4-6
68
MS 400W/C/H75/ED28/PS/737
55459
38000
95
30000
20000+ 3700
2-3
4-6
70
Case
Fig. Qty
C
6
C
6
A
12
Coated V±15°
Clear HOR±75°
A
12
C
6
Clear HOR±75°
Coated HOR±75°
A
12
A
12
Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours.
**At 120 or more hours per start, lamp life is rated at 30,000 hours
***A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours.
ELECTRONIC BALLAST Housings 60Hz Ventronic™
Product Number
OPE400HF208-277-(X)
Voltage
208-277
Input Voltage
188-305
Input Watts Maximum Line Current ANSI Code
430
430/(.92*Vline)
M155
Fig.
1
Tot. Wt. (lbs)
15
EMI
FCC Part 18
MAGNETIC BALLASTS 60Hz ANSI M135/M155
Input
Voltage
277
Product
No.
V90U7621
Circuit Input
Type Watts
Reactor 435
Max. Line
Current
2.10
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
C
B1 2 1.65 3.7
7 20/280 A7 Dry D 2
120/208/240/277 V90D7612
CWA
450 4.00/2.30/2.00/1.75 C/C/C/C
E
3
2
3.9
10.7 26/330 A3 Dry D
120/277/347
V90J7612
CWA
451
4.00/1.75/1.40
D/D/D
K
3
2.15
4
11.3 26/330 A3 Dry D
480/120T
V90Y7612T
CWA
455
1.00
D
S1
3
2.2
4.1
12
26/330 A3 Dry D
2
2
2
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
OPE
10.1
12.0
REACTOR
2 33/4 x 41/2 Core
1
4.50"
(114mm)
10.0
14.2
Weight = 15 lbs.
Width = 12”
Length = 10.1”
Height = 14.2”
4.05"
(103mm)
A
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
3 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
9.6
7.6
34
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
B
HX & CWA
ED28
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Ballast Options
D
ED37
C
ED37
B
ED28
A
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
450 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield®
Lamp
Description
MP 450W/BU/EL/UVS/PS/740
Product
No.
30285
Initial Lumens Mean Avg. Life CCT Warm-Up Restrike
Lumens Per Watt Lumens Hours** (K) (Min) (Min) CRI
47000
104
40000 20000++ 4000 2-3
5-8
68
Oper.
Finish
Pos.
Clear BU±15°
MP 450W/C/BU/EL/UVS/PS/737
24908
45000
Coated BU±15°
100
39000
20000++ 3700
2-3
5-8
70
featuring UV
Open Rated LAMPS ANSI Type-O M144/O Mogul Base
Lamp
Description
MP 450W/BU/UVS/PS/740
Product
No.
65072
Initial Lumens Mean
Lumens Per Watt Lumens
47000
104
37000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
5-8
68
Oper.
Finish
Pos.
Clear BU±15°
MP 450W/C/BU/UVS/PS/737
59216
45000
20000+ 3700
Coated BU±15°
100
36000
2-3
5-8
70
Case
Fig. Qty
B 6
B
6
Shield®
Case
Fig. Qty
B 6
B
6
Enclosed Rated LAMPS ANSI Type-E M144/E Mogul Base
Lamp
Description
MS 450W/V/PS/740
Product
No.
10079
Initial Lumens Mean
Lumens Per Watt Lumens
50000
111
40000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 2-3
4-6
68
Finish
Clear
MS 450W/C/V/PS/737
10138
47000
20000+ 3700
Coated V±15°
104
37000
2-3
4-6
70
Oper.
Pos.
V±15°
Applications
• Highbay Industrial
• Manufacturing Lighting
Case
Fig. Qty
A 6
A
6
Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours.
**A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours.
UNI-FORM®
Systems
ELECTRONIC BALLAST Housings 60Hz Ventronic™
Product Number
OPE450HF277-(X)
Voltage
277
Input Voltage
249-305
Input Watts Maximum Line Current ANSI Code
465
465/(.92*Vline)
M144
Fig.
1
Tot. Wt. (lbs)
15
EMI
FCC Part 18
MAGNETIC BALLASTS 60Hz ANSI M144
Input
Voltage
277
Product
No.
V90U8521
Circuit Input
Type Watts
Reactor 485
120/208/240/277 V90D8512
CWA
120/208/240/277 V90D8530
120/277/347
V90J8511
120/277/347
V90J8530
480/120T
V90Y8512T
480/120T
V90Y8530T
Max. Line
Current
2.30
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
C
B1 2 1.8 3.75 8.1 22/280 A2 Dry D 2
506 4.40/2.50/2.20/1.90 C/D/D/D
E
3
2.3
4.2
HX-HPF 505 7.00/3.60/3.50/3.00 B/A/D/D
Y
3
2.4
4.5
CWA
12.4 32/300 A10 Dry D
14
2
30/280 A7 Dry D
2
2
507
4.40/1.90/1.50
D/D/D
K
3
2.3
4.2
12.4 32/300 A10 Dry D
HX-HPF 510
6.25/2.55/2.20
D/B/D
A1
3
2.6
4.5
14.5 30/280 A7 Dry D
2
515
1.10
D
S1
3
2.3
4.2
12.5 32/300 A10 Dry D
2
HX-HPF 515
1.75
D
W1
3
2.6
4.5
CWA
14
30/280 A7 Dry D
2
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
Ballast Options
B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
ED37
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
OPE
10.1
12.0
REACTOR
2 33/4 x 41/2 Core
1
4.50"
(114mm)
3.75"
(95 mm)
3.30"
(84 mm)
9.6
10.0
14.2
7.6
Weight = 15 lbs.
Width = 12”
Length = 10.1”
Height = 14.2”
3 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
4.05"
(103mm)
A
B
HX & CWA
ED37
A
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
35
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
575 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS ANSI Type-O M178/O
EX39 Mogul Base
Lamp
Description
MP 575W/BU/BT37/PS/740
Product
No.
60023
Initial Lumens Mean
Lumens Per Watt Lumens
60000
104
48000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 3-5
8-12 68
Oper.
Finish
Pos.
Clear BU±15°
MP 575W/C/BU/BT37/PS/737
60020
57000
20000+ 3700
Coated BU±15°
99
45000
3-5
8-12
70
Case
Fig. Qty
A 6
A
6
MAGNETIC BALLASTS 60Hz ANSI M178
Applications
• Site Lighting
• Highbay Industrial
Input
Voltage
277
Product
Circuit Input
No.
Type Watts
V90U5521 Reactor 620
Max. Line
Current
3.30
480
V90Y5530T HX-HPF 645
2.30
W1
2
3.25
5
120/208/240/277
V90D5530 HX-HPF 635 8.75/4.70/4.45/3.80 B/A/C/C
Y
2
3.25
5
18
38/330 A14 Dry D
2
120/277/347
V90J5530 HX-HPF 635
A1
2
3.25
5
18
38/330 A14 Dry D
2
9.75/3.70/3.20
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
D
B1 1 2.05 3.85 8 30/280 A2 Dry D 2
D
D/C/D
18.5 38/330 A14 Dry D
2
Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours.
Benefits
• Twice the mean lumens of
a 400W standard probe
start metal halide lamp
• 60,000 initial lumens
• Long life: 20,000+ hours
• Brightest lamp in its class
575 Watt
Pulse Start
400 Watt
Standard Probe Start
36
Number of Fixtures:
72
Illuminance:
31 fc
111,600 kWh
BT37
vs
32 fc
.80
A
Light Loss Factor:
Energy Consumption:
.65
163,800 kWh
$
4,176/year
Savings
0
%
30 Energy Savings 0
Note: based on 5000 hours/year operation at $.08/kWh
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
4.50"
(114mm)
2 4x4 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
4.05"
(103mm)
A
B
HX & CWA
1 33/4 x 41/2 Core
REACTOR
UNI-FORM®
Systems
Highbay Lighting Layout Comparison
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
36
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
875 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Open Rated LAMPS ANSI Type-O M166/O
Lamp
Description
MP 875W/BU/BT37/PS/740
Product
No.
58953
Initial Lumens Mean
Lumens Per Watt Lumens
95000
109
76000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 3-5
8-12 68
Oper.
Finish
Pos.
Clear BU±15°
MP 875W/C/BU/BT37/PS/737
41686
90000
20000+ 3700
70
Coated BU±15°
103
72000
3-5
8-12
Case
Fig. Qty
C
6
C
6
Enclosed Rated LAMPS ANSI Type-E M166/E
Lamp
Description
MS 875W/BU/BT37/PS/740
Product
No.
22619
Initial Lumens Mean
Lumens Per Watt Lumens
100000 114
80000
Avg. Life CCT Warm-Up Restrike
Hours*
(K) (Min) (Min) CRI
20000+ 4000 3-5
8-12 68
Oper.
Finish
Pos.
Clear BU±15°
MS 875W/BD/BT37/PS/740
35426
100000
114
80000
20000+ 4000
3-5
8-12
68
Clear BD±15°
A
6
Applications
MS 875W/HOR/BT37/PS/740**
33759
95000
109
76000
12000
3-5
8-12
68
Clear HOR±45°
B
6
• Retail Auto Lots
4000
Case
Fig. Qty
A 6
Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours.
**Permitted rotation about horizontal lamp axis ±15Ëš.
• Highbay Industrial Lighting
MAGNETIC BALLASTS 60Hz ANSI M166
• Indoor Sports/Recreation
Max. Line
Current
2.75
• Aircraft Hangers
Product
Circuit Input
No.
Type Watts
V90Y8620 Reactor 925
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
C
B1 1 3.3 5.2 13.5 15/480 B9 Oil F 5
120/208/240/277
V90D8611
CWA
940 8.00/4.50/4.00/3.45 B/A/A/A
E
2
2.8
4.8
22/460 B12 Oil
F
10
120/208/240/277
V90D8612
CWA
940 7.85/4.85/4.05/3.45 B/C/B/B
E
2
2.8
4.95 18.5 22/470 B12 Oil
F
10
21
120/277/347
V90J8611
CWA
940
8.00/3.45/2.75
A/A/A
K
2
2.93
4.95
22
22/460 B12 Oil
F
5
480
V90Y8611T
CWA
945
2.00
C
S1
2
2.82
4.85
21
22/460 B12 Oil
F
2
480
V90Y8612T
CWA
950
2.00
C
S1
2
2.8
4.9
18.5 22/470 B12 Oil
F
10
Benefits
• A great replacement for a
1000 watt standard probe
start metal halide system!
• Save up to 155 watts
per luminaire
• High lumen output:
100,000 lumens -115
lamp lumens per watt
A
B
C
BT37
BT37
BT37
• Long life: 20,000+ hours
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
4.50"
(114mm)
2 4x6 Core
HOLES CLEARED
FOR # 10 BOLTS
3.75"
(95 mm)
3.30"
(84 mm)
4.05"
(103mm)
A
B
CWA
REACTOR
1 33/4 x 41/2 Core
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
6.00"
(152 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
3.87"
(98 mm)
4.375"
(111 mm)
5.375"(136 mm)
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
37
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
UNI-FORM®
Systems
Input
Voltage
480
1000 Watt
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Enclosed Rated LAMPS ANSI Type-E M141/E Mogul Base
Lamp
Description
MS 1000W/BU/BT37/PS/740
Product
No.
71722
Initial Lumens Mean
Lumens Per Watt Lumens
115000 115
86000
MS 1000W/HOR/T25/PS/734*
49111
110000
110
Avg. Life CCT Warm-Up Restrike
Hours
(K) (Min) (Min) CRI
12000 4000 3-5
8-12 68
77000
5000
3400
3-5
10-15
68
Oper.
Finish
Pos.
Clear BU±15°
Clear HOR±45°
Case
Fig. Qty
A 6
B
6
Notes: * Permitted rotation about horizontal lamp axis ±15Ëš
MAGNETIC BALLASTS 60Hz ANSI M141
Applications
Product
No.
V90D7810
Circuit Input
Max. Line
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist.
Type Watts
Current
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft)
CWA 1080 9.00/5.20/4.50/3.90 D/A/B/B
E
1 2.8 4.8 21 24/480 B12 Oil F 10
120/208/240/277
V90D7811
CWA
1080 8.95/5.55/4.55/3.95 D/D/C/D
E
1
2.8
4.95 18.5 24/480 B12 Oil
F
10
120/277/347
V90J7810
CWA
1080
9.00/3.90/3.15
D/B/A
K
1
2.93
4.95 21.5 24/480 B12 Oil
F
10
480/120T
V90Y7810T
CWA
1080
2.25
D
S1
1
2.82
4.85
21
24/480 B12 Oil
F
10
480/120T
V90Y7811T
CWA
1085
2.35
E
S1
1
2.8
4.85
21
24/480 B12 Oil
F
10
Fun Facts
A
B
BT37
T25
The United States consumes
25% of all the world’s energy
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Dia. = 3 1/8” (79mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
1 4x6 Core
CWA
UNI-FORM®
Systems
• Energy Saving Retrofits
• Highbay Industrial
• Site Lighting
Input
Voltage
120/208/240/277
6.00"
(152 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
3.87"
(98 mm)
4.375"
(111 mm)
5.375"(136 mm)
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
38
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Go Green: Retrofit and Save!
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Other Energy Saving Options
HIDirect has the widest selection and variety of energy
saving pulse start
Old Standard HIDirect’s Energy
metal
halide Probe Start Saving Uni-Form®
lighting systems. Wattage
Pulse Start Solution
Achieve equal or 1000W
875W
more light while
775W Natural White®
using less energy
575W
compared
to
400W
450Wwith fewer fixtures
older standard
350W
probe start metal
320W
halide wattages.
250W
200W
With so many
175W
options available,
175W
150W
HIDirect has the
125W
perfect
energy
100W
saving solution
for all your lighting needs.
Before
Replace standard probe start
1000 Watt with
875 Watt
Lamp Lumens
100,000
After
Uni-Form®
875W
80,000
60,000
40,000
Standard
Probe Start
1000W
12,000
10,000
15,000
UNI-FORM®
Systems
5,000
20,000
Hours of Operation
45,000
Lamp Lumens
40,000
35,000
Uni-Form®
320W
Replace standard probe start
400 Watt with
30,000
20,000
Concrete Example:
320 Watt
25,000
Standard
Probe Start
HIDirect’s distribution center, located
in Streetsboro, Ohio, replaced (20)
1000 watt standard probe start metal
halide fixtures with (6) HIDirect® 875
watt pulse start metal halide fixtures
in the shipping department area.
400W
15,000
5,000
10,000
15,000
20,000
Hours of Operation
Realized Benefits:
22,000
Lamp Lumens
18,000
Replace standard probe start
250 Watt with
200 Watt
Uni-Form®
200W
• Saved $6,384 per year
• Increased the light levels over
150% (2.5 times the illuminance
level)
14,000
10,000
• Reduced the number of fixtures
from 20 to 6
Standard
Probe Start
250W
• Saved over 140 watts of energy
per fixture
(Rated Lamp Life
10,000 Hours)
6,000
5,000
10,000
15,000
Hours of Operation
Lamp Lumens
16,000
Uni-Form®
125W
12,000
8,000
Replace standard probe start
175 Watt with
125 Watt
Standard
Probe Start
175W
(Rated Lamp Life
10,000 Hours)
4,000
5,000
10,000
15,000
Hours of Operation
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
39
Wiring Diagrams
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Uni-Form® Pulse Start Systems
Wiring diagrams for all Uni-Form pulse start ballast
products are provided on this page. The ballast data
tables indicate the reference letter corresponding to the
correct diagram for each ballast product. Refer to the
table for the required ballast before referencing any
diagram.
The wiring diagram is the blueprint for the ballast
circuitry, including the input supply voltage and
grounding methods. A ground connection must be made
to all ballasts to avoid shock hazard, personal injury or
damage to the luminaire or installation. Ballast
installations and groundings should be made in
accordance with all applicable government codes and
regulations where required.
E
K
Y
A1
B1
Q1
S1
T1
W1
UNI-FORM®
Systems
A
40
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Retrofit Systems
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
Ballast Housings and Track Lighting
Benefits of Retrofitting
• Ballast and components are pre-installed at the factory
- Saves labor costs
- Avoids unnecessary warranty issues
• Cost is less than a new fixture
• Less overall expense than retrofitting just lamp and
ballast
• Retaining your existing optics will preserve the same
light pattern and dispersion
- Avoids additional lighting layout cost
4. Heat shield
4
5. Mounting bracket
5 6
6. Open-rated (pink) socket
7. Open-rated lamp
8. White cord
7
UNI-FORM®
Systems
• Examples of open-rated optics that can be used:
Sold with brackets to fit the following reflectors
- All aluminum reflectors over 15”
- All glass reflectors
- All acrylic or polycarbonate
refractors/reflectors over 16”
Components of the Ballast Housing:
1
1. Hook
8
2.Wiring box with black cord
2
3. Ballast housing
3
• Higher lumen package than standard probe start
metal halide
Retrofit
Systems
Performance Plus™
35W Metal Halide
Track Lighting Fixture
Use Your Existing Reflector
& Save Time and Money!
Savings
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
41
Retrofit Ballast Housings
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
ELECTRONIC BALLAST Housings 60Hz Ventronic™
Product Number
OPE320HF208-277-(X)
Voltage
208-277
Input Voltage
188-305
OPE350HF208-277-(X)
208-277
188-305
375
375/(.92*Vline)
OPE400HF208-277-(X)
208-277
188-305
430
430/(.92*Vline)
277
249-305
465
465/(.92*Vline)
OPE450HF277-(X)
• Retail Auto Lots
Line Side Characteristics
• Highbay Industrial Lighting
THD %
Min Power Factor %
Ballast Line Current Data (max @ low line)
320W
Starting Current
320W
Operating Current
350W
Starting Current
350W
Operating Current
400W
Starting Current
400W
Operating Current
450W
Starting Current
450W
Operating Current
General information
System Efficiency %
Ballast Factor
Light output at 35% Watts (Full Dim)
• Aircraft Hangers
• Indoor Sports/Recreation
UNI-FORM®
Systems
Fig.
1
Tot. Wt. (lbs)
15
EMI
FCC Part 18
M131
1
15
FCC Part 18
M155
1
15
FCC Part 18
M144
1
15
FCC Part 18
Notes: Sold with open rated socket and lamp. Shipped with 5 foot white cord. All ballast housings are shipped pre-wired to a specific voltage for the existing
plug. If you are using a different voltage, the ballast will need to be re-wired. For direct wire/slice-box installations, remove cord and wire through
wiring box. No plug or safety chain is provided. Use existing plug and safety chain or provide new components for installation.
Options: Add Suffix for Options: QTZ - Quartz restrike control; D - Dimming; Standard, two wire 0-10V, DC control.
Warranty and Standards: Electronic Ballast 3 years, Lamp 2 years. No warranty for quartz restrike lamp. See “One Call Warranty” for details
UL Listed: Approved for damp location; Indoor open high bay applications only. Operating Temperature: -30º to 55ºC; Ambient per UL1598
Applications
Benefits
Compared to standard
probe start systems:
• Longer life
• Energy savings
• Improved color uniformity
• Faster warm-up and
restrike
• Better lamp survival rates
208V in
<5%
99
240V in
<5%
99
277V in
<5%
99
0.07
1.67
0.07
1.83
0.07
2.09
N/A
N/A
0.07
1.45
0.07
1.59
0.07
1.81
N/A
N/A
0.065
1.27
0.065
1.38
0.065
1.57
0.065
1.81
93
1
<12%
93
1
<12%
93
1
<12%
1
OPE
Retrofit
Systems
Input Watts Maximum Line Current ANSI Code
342
342/(.92*Vline)
M154
10.1
12.0
9.6
10.0
14.2
7.6
Weight = 15 lbs.
Width = 12”
Length = 10.1”
Height = 14.2”
System Benefits
HIDirect’s retrofit ballast housings contain Uni-Form® pulse start metal halide lighting systems
with patented formed body arc tube lamps and quieter, cool-running Opti-Wave® ballasts.
42
• Longer life - up to 50% longer than standard
probe start metal halide
• Energy savings - more system lumens per watt
means more light for less energy
• Improved color uniformity - for minimal color
variation from lamp to lamp
• Faster warm-up and restrike - one third the
time
• 70% survival at end of rated life - a 40%
improvement over standard probe start metal
halide - 80% survival for lamps on electronic
ballasts
• Fewer lamp failures and less breakage in shipping
because of patented stronger weldless mount
• Open-rated lamp (ANSI Type-O)
- No luminaire lens required, delivers more light
- Operational 24/7 - no shut-off required
- Blocks nearly all damaging ultraviolet light with
UV Shield® technology
- Meets 2005 National Electric Code® criteria
for open fixtures
• Pleasant environment and better system
performance thanks to quiet, cool-running
Opti-Wave® ballasts
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Retrofit Ballast Housings
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
MAGNETIC BALLAST Housings 60Hz
Watts
200
Input
Voltage
277
Product
No.
OPM-2-200U
ANSI
Code
M136
Circuit
Type
Reactor
Input
Watts
219
Max. Line
Current
1.25
Fig.
2
Tot. Wt.
(lbs)
11.5
14.5
200
120/208/240/277
OPM-3-200D(options)
M136
HX-HPF
235
3.30/2.05/1.65/1.45
2
200
480
OPM-3-200Y
M136
HX-HPF
235
0.8
2
15
250
277
OPM-2-250U
M153
Reactor
275
1.35
2
13
250
120/208/240/277
17
320
277
320
320
OPM-1-250D(options)
M153
CWA
288
2.50/1.45/1.25/1.10
2
OPM-2-320U
M132/M154
Reactor
349
1.7
2
14
120/208/240/277
OPM-3-320D(options)
M132/M154
HX-HPF
360
4.80/2.85/2.45/2.10
2
18
120/208/240/277
OPM-1-320D(options)
M132/M154
CWA
365
3.15/1.85/1.60/1.40
2
18.5
320
120/277/347
OPM-1-320J(options)
M132/M154
CWA
368
3.20/1.40/1.15
2
18.5
320
480
OPM-1-320Y
M132/M154
CWA
370
1.2
2
18.5
480
OPM-3-320Y
M132/M154
HX-HPF
370
1.2
2
18.5
350
277
OPM-2-350U
M131
Reactor
380
1.9
2
14.4
350
120/208/240/277
OPM-3-350D(options)
M131
HX-HPF
395
5.00/2.55/2.50/2.15
2
18
350
480
OPM-3-350Y
M131
HX-HPF
400
1.35
2
21.5
400
277
18.5
400
120/208/240/277
400
450
OPHM-2-400U
M155
Reactor
435
2.1
3
OPHM-1-400D(options)
M155
CWA
450
4.00/2.30/2.00/1.75
3
20.2
480
OPHM-1-400Y
M155
CWA
455
1
3
21.5
277
OPHM-2-450U
M144
Reactor
485
2.3
3
17.6
120/208/240/277
450
480
575*
277
575*
120/208/240/277
575*
OPHM-3-450D(options)
M144
HX-HPF
505
7.00/3.60/3.50/3.00
3
23.5
OPHM-3-450Y
M144
HX-HPF
515
1.75
3
23.5
OPHM-2-575U
M178
Reactor
620
3.3
3
17.5
OPHM-3-575D(options)
M178
HX-HPF
635
8.75/4.70/4.45/3.80
3
27.5
480
OPHM-3-575Y
M178
HX-HPF
645
2.3
3
28
875*
480
OPHM-2-875Y
M166
Reactor
925
2.75
3
23
875*
480
OPHM-1-875Y
M166
CWA
945
2
3
30.5
875*
120/208/240/277
OPHM-1-875D(options)
M166
CWA
940
8.00/4.50/4.00/3.45
3
30.5
• Indoor Highbay Lighting
Benefits
• Replacement standard
probe start metal halide
systems for energy saving
pulse start systems!
• Save up to 155 watts
per luminaire
• Acheive up to 115 lamp
lumens per watt
• Long life: 20,000+ hours
= HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007.
* = Systems above 500 watts are exempt from California Title 20 and federal Energy Independence & Security Act of 2007 requirements.
Notes: Sold with open rated socket and lamp. Shipped with 5 foot length white cord. All ballast housings are shipped pre-wired to a specific voltage for the
existing plug. If you are using a different voltage, the ballast will need to be re-wired. For direct wire/slice-box installations, remove cord and wire
through wiring box. No plug or safety chain is provided. Use existing plug and safety chain or provide new components for installation.
Options: Add Suffix for Options: QTZ - Quartz restrike control; D - Dimming; Standard, two wire 0-10V, DC control.
Warranty and Standards: Magnetic Ballast 5 years, Lamp 2 years. No warranty for quartz restrike lamp. See “One Call Warranty” for details
UL Listed: Approved for damp location; Indoor open high bay applications only. Operating Temperature: -30º to 55ºC; Ambient per UL1598
12.0
10.0
10.7
15.3
Width = 12”
Length = 10”
Height = 15.3”
OPHM
3
OPM
2
15.6
13.1
10.2
11.5
9.4
15.4
5.2
Width = 15.6”
Length = 11.5”
Height = 15.4”
4.6
11.5
10.0
43
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Retrofit
Systems
450
Applications
UNI-FORM®
Systems
320
Track Lighting Systems
U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S
35 Watt Electronic Track Lighting Systems
# of
Lamp
Lamps Type
Single MR16
Product
Description
VETF-J35W1-GX10-WH
Part
Center Beam Beam
Beam
Avg. Life CCT
Number Candle Power Angle°
Type
Hours (K)
60622 23000cd
9 Very Narrow Spot 6000 5000
Twin
MR16 VETF-J35W2-GX10-WH
60633 23000cd
NOTE: Required HIDirect Lamp Parts # 60621, 60631, 60632 (figure 3)
9
Very Narrow Spot
6000
CRI
90+
5000
System Input
Connector
Watts Voltage Fig. Type
43
120
1
J
90+
87
120
2
J
Performance Plus™ MR16 LAMPS
Applications
Lamp Lamp
Type Description
MR16 MPSE 35W/GX10/MR16/950/SP/WH
Product Center Beam
Number Candle Power
60621
23000
Beam
Angle°
9
Beam
Type
Very Narrow Spot
• Showcase Lighting
MR16 MPSE 35W/GX10/MR16/950/NFL/WH
60631
• Track Lighting
MR16 MPSE 35W/GX10/MR16/950/WFL/WH
60632
Avg. Life CCT
Hours (K)
6000 5000
12500
20
Narrow Flood
6000
4800
40
Wide Flood
6000
CRI
90+
Fig.
3
Input
Voltage
120
5000
90+
3
120
5000
90+
3
120
• Retail Lighting
• Art Gallery/Museum
Lighting
Low Wattage Accent Lighting
UNI-FORM®
Systems
Benefits of HIDirect’s electronic, low watt, metal halide
track lighting systems for high powered accent lighting
with less energy and more life and light
The HIDirect Advantage
• High efficiency
• High CRI
Retrofit
Systems
• Beam control: tight beam angle
• Small size
• Maximum punch
• More choices across the visual color spectrum
2
FIXTURE
Width = 9.9” (251mm)
Height = 7.38” (187mm)
Depth = 2.38” (60mm)
Track Type = J
3
LAMP
1
FIXTURE
• Direct from the manufacturer
12.52
Width = 12.52” (318mm)
Height = 7.38” (187mm)
Depth = 2.38” (60mm)
Track Type = J
44
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
MR16
Dia. = 2.375” (60mm)
MOL = 3.6” (92mm)
Base = GX10
Specialty Lamps
SPECIALTY METAL HALIDE LAMPS
The Right Lamp For That
Special Application
Our Energy Master® Retrofit Lamps: Relamp your standard
probe start metal halide installation with these 150 watt or
360 watt energy-saving retrofit products; lamps are
specifically designed to operate with all standard probe
start metal halide fixtures and ballasts. Energy saving pulse
start lamps are also available.
White-Lux® Lamps: 250 - 750 watts - Cost effectively switch
from yellow HPS light to white metal halide light without
modifications to your HPS ballasts and fixtures.
Tubular Lamps: 70 - 1000 watts - Tubular jacketed lamps
with highly streamlined profiles provide excellent optical
control.
BiPin (G12) Lamps: 70 - 150 watts
Double Ended Lamps: 70 - 250 watts - Compact
configuration provides excellent optical control in smaller
fixture designs.
High Wattage Double Ended Lamps: 1000 - 2000 Watts These European style lamps are used for large area
floodlighting and sports lighting applications.
High Wattage/Sports Lamps: 1000 - 1650 watts - These
lamps are the leading choice for arenas and stadiums
worldwide.
Specialty
Lamps
Unique
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
45
®
gy
Ener Master Lamps
SPECIALTY METAL HALIDE LAMPS
featuring UV
Open Rated PROBE START LAMPS ANSI Type-O
Shield®
Lamp
Watts Description
360 MPI 360W/BU/EM
Product
No.
38029
ANSI
Initial Lumens Mean Avg. Life CCT
Operating
Case
Watts
Spec
Lumens Per Watt Lumens Hours (K) CRI Finish Pos. Fig. Qty Replaces Saved
M59/165/O 36000 100 23000 20000 4000 65 Clear BU±15° C 6 400/U; 400/BU 40
360
67293
M59/165/O 34000
MPI 360W/C/BU/EM
94
22000 20000 3700 70 Coated BU±15° C
6 400/C/U; 400/C/BU 40
ANSI
Initial Lumens Mean Avg. Life CCT
Operating
Case
Watts
Spec
Lumens Per Watt Lumens Hours (K) CRI Finish Pos. Fig. Qty Replaces Saved
M57/107/E 13500 90 8800 10000 4000 65 Clear U
A 12 175/U/MED 25
150
MH 150W/C/U/EM
39083
M57/107/E 12800
85
8300 10000 3700 70 Coated U
A
12 175/C/U/MED 25
150
MH 150W/U/ED28/EM
69559
M57/107/E 13500
90
8800 10000 4000 65 Clear
B
12 175/U; 175/BU 25
A
B
C
BT37
Specialty
Lamps
• Energy Saving
Applications Indoors or
Outdoors
Product
No.
44810
ED28
Applications
Lamp
Watts Description
150 MH 150W/U/EM
ED17
Enclosed Rated PROBE START LAMPS ANSI Type-E
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
46
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
U
®
gy
Ener Master Lamps
SPECIALTY METAL HALIDE LAMPS
Change Just The Lamp!
Retrofit for Safety
For applications where safety is an issue, HIDirect offers
open-rated Energy Master® MPI (probe start) lamps,
which meet 2005 NEC® (National Electric Code)
requirements. The arc tube is enclosed within a quartz
shroud to prevent the outer glass jacket from breaking in
the event of an arc tube rupture, passing ANSI
containment tests. These Lamp types are intended
primarily for open-rated fixtures and provide an added
measure of safety in enclosed fixtures.
Retrofit Benefits:
• No need to change luminaires or ballasts
• Save on energy consumption
• Safe alternative - Open-rated lamps available in
360 watt standard probe start metal halide lamps
• Clear and coated outer jacket options available
• Watch your energy savings grow with
Energy Master!
• Indoor or outdoor, Energy Master lamps are perfect
for energy savings in any application
Energy Savings
A Simple Lamp Change Does It!
Save Up to 40 watts per Fixture! Our Energy Master line
of retrofit products saves energy by operating at lower
wattages.
See an immediate reduction in energy costs of up to 40
watts per fixture or a full 10% with virtually the same light
output. For example, at a cost of $0.12/KWH, the
energy savings over the rated life of the 360 watt Energy
Master lamp (rated at 20,000 hours) is $64 per fixture.
Calculation: .040 KW/hr x $.12 x 20,000 hrs = $96.00
Simple
Change Just the Lamp!
Considering an update of your lighting system? Explore
the advantages of the Energy Master line - just replace
your lamp. That’s it! The high cost of a whole new
lighting system or the labor cost of re-wiring or installing
new wiring is not needed with Energy Master energy
saving retrofit lamps. Use existing luminaires and
ballasts.
Specialty
Lamps
47
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
White-Lux Lamps
®
SPECIALTY METAL HALIDE LAMPS
featuring UV
Open Rated PROBE START LAMPS ANSI Type-O
Lamp
Watts Description
250 MPI 250W/BU/LU
Product ANSI
Initial Lumens Mean Avg. Life CCT
No. Compatible Lumens Per Watt Lumens Hours
(K) CRI
24785 S50/O* 19000
70
12300 10000 4000 65
250
MPI 250W/C/BU/LU
10206
18000
67
11700
10000
3700
70 Coated BU±15°
B
12
LU 250/C
400
MPI 400W/BU/LU
10044 S51/O** 39000
91
25400
20000
4000
65
E
6
LU 400
S50/O*
Operating
Case
Finish Pos.
Fig. Qty
Clear BU±15° B
12
Shield®
Clear
BU±15°
Replaces
LU 250
Enclosed Rated PROBE START LAMPS ANSI Type-E
Lamp
Watts Description
250 MH 250W/U/LU
• Parking lot lighting
• Retail illumination
operation and dimming
capabilities.
• Complete electrical
compatibility with HPS
systems
• Designed for photometric
compatibility with HPS
systems
• Clear and coated outer
jacket options
• Shrouded open-rated
lamps available in 250
and 400 watts, complies
with 2005 National
Electric Code
• Excellent color rendering
(65-70 CRI vs. 22 CRI for
HPS)
MH 400W/U/LU/ED28
59441
S51/E** 41000
95
26600
20000
4000
65
Clear
U
A
12
LU 400
400
MH 400W/U/LU
52134
S51/E** 41000
95
26600
20000
4000
65
Clear
U
C
6
LU 400
400
MH 400W/C/U/LU
72190
S51/E** 39000
91
25400
20000
3700
70 Coated
U
C
6
LU 400/C
750
MH 750W/U/LU/BT37
33940 S111/E*** 72000
96
46800
12000
4000
65
Clear
U
D
6
LU 750
1000
MS 1000W/V/LU/BT37
35892
110
71500
15000
4000
65
Clear
V±15
D
6
LU 1000
*
**
***
†
S52/E† 110000
Lamp operates on 250W(S50) high pressure sodium ballast.
Lamp operates on 400W(S51) high pressure sodium ballast.
Lamp operates on 750W(S111) high pressure sodium ballast.
Lamp operates on 1000W(S52) high pressure sodium ballast.
A Simple Lamp Change Does It
It’s easier than ever to switch from the harsh yellow light of
high pressure sodium to the clear, white light of metal
halide. Make the change just by replacing the lamp!
HIDirect’s unique White-Lux lamps are completely
compatible with all HPS lighting systems and fit directly into
your existing 250, 400, 750 or 1000 watt HPS fixture. No
need to change ballasts, ignitors, or even reposition the
socket.
The crisp, 4K color of White-Lux replacement lamps reduces
glare in your warehouse or building and creates a better,
brighter work environment. Reduce errors and improve
your business efficiency with this simple change to whiter
light. White-Lux high output metal halide lamps are the
easy, cost-effective solution to your retrofit needs. Save on
costs, increase productivity, raise sales. You’re sure to see
the bright results with the White-Lux advantage!
Switch To Bright, White Light
From Existing HPS Fixtures
As Simple As A Change Of A Lamp
A
B
ED28
Specialty
Lamps
Change Just
the Lamp:
Replaces
LU 250
400
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
C
D
E
BT37
• Warehouse downlighting
Operating
Case
Pos.
Fig. Qty
U
A
12
BT37
• Building and security
floodlighting
Finish
Clear
ED37
• Industrial highbay
ED28
Applications
Product ANSI
Initial Lumens Mean Avg. Life CCT
No. Compatible Lumens Per Watt Lumens Hours
(K) CRI
91051 S50/E* 20000
74
13000 10000 4000 65
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
48
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
High Wattage/Sports
SPECIALTY METAL HALIDE LAMPS
Enclosed Rated PROBE START LAMPS ANSI Type-E Mogul Base
Watts
1000
Lamp
Description
MS 1000W/HOR/SPORT 60
Product
No.
47503
ANSI
Code
M47/E
Initial
Lumens
115000
Mean
Lumens
86000
1000
MS 1000W/HOR/BT37/3K
53702
M47/E
115000
86000
3400 70
Clear
HOR±45°
C
6
1500
MH 1500W/HBU
18360
M48/E 161000BU 136000BU 3000BU/H 3400 65
Clear
BU±105°
A
6
57
1500
MH 1500W/U/XL
12342
M48/E 170000V
Clear
U
A
6
57
1500
MS 1500W/HOR/XP/SPORT 60
82070
M48/E
162000
137700
3000
3400 70
Clear
HOR±60°
B
6
57
1650
MS 1650W/HOR/XP/SPORT 60
16419
M112/E 177000
145000
3000
3200 70
Clear
HOR±60°
B
6
57
136000V
Avg. Life CCT
Hours
(K) CRI
12000 3400 70
12000
6000V
Operating
Case Ballast
Finish Position Fig. Qty Ref. Pg.
Clear HOR±60° B
6
57
4000 65
57
Benefits:
• Brighter - High lumen
output
• “Extra Life” lamp available
HIDirect’s MH 1500W/U/XL
lamp has a 6000 hour
rated life
• HIDirect’s Sports 60 lamps
are designed for sports
lighting aiming angles
Electrical Connections:
HIDirect offers a wide range of Sports Lighting options,
including the compact MS 1000/HOR/BT37 designed
for indoor arenas and the 1500 and 1650 watt Sport 60
lamps for applications in both recreational and
professional athletic sites.
• Weldless key electrical connections maintain lamp
circuit integrity, even when subjected to pole-top
noise, vibration and harshness (NVH)
Structurally Stronger:
• Less color shift
• Weldless frame connections minimize shipping
damage and claims
• Increases voltage stability
Dia. = 7” (180mm)
MOL = 15 3/8” (391mm)
LCL = 9 1/2” (241mm)
Base = E39
• Improves performance
• Good color rendition
(65-70 CRI)
• High Wattage double
ended versions available
Spec the System: Matching lamp and ballast specs
available
C
BT37
BT56
B
BT56
A
Electrically Neutral Frame:
• High lumen output lamps
for efficient layout designs
Dia. = 7” (180mm)
MOL = 15 3/8” (391mm)
LCL = 9 1/2” (241mm)
Base = EP39 (POMB)
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
49
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Specialty
Lamps
A Simple Lamp Change Does It
• Compact BT37 for
excellent optical control
(MS 1000/HOR/BT37)
Tubular Lamps
SPECIALTY METAL HALIDE LAMPS
Enclosed Rated PROBE START LAMPS ANSI Type-E
Watts
175
Lamp
Description
MH 175W/U/T15
Product
No.
40335
ANSI
Code
M57/E
175
MH 175W/U/T15/10K
70136
M57/E
-
-
-
250
MH 250W/U/T15
33479
M58/E
21000
84
13700
250
MH 250W/U/T15/10K
63897
M58/E
-
-
-
250
MS 250W/HOR/T15*
88353
M58/E
23000
92
250
MS 250W/HOR/T15/3K*
54843
M58/E
21000
84
400
MH 400W/U/T15
55422
M59/E
36000
90
• Landscape Lighting
400
MS 400W/HOR/T15*
55100
M59/E
• Downlighting - Low Ceiling
400
MS 400W/HOR/T15/3K*
32225
M59/E
Applications
• Sconce Lighting
CCT
(K)
4000
CRI Finish
65 Clear
8000
10000
65
Clear
U
A
10000
4000
65
Clear
U
A
12 56
8000
10000
65
Clear
U
A
12 56
15000
10000
4000
65
Clear HOR±45° A1
12 56
13700
10000
3200
65
Clear HOR±45° A1
12 56
23000
15000
4000
65
Clear
B
12 57
40000
100 26000
15000
4000
65
Clear HOR±45° B1
12 57
38000
95
15000
3200
65
Clear HOR±45° B1
12 57
24000
Oper.
Pos.
U
®
12 56
TECHNOLOGY
Watts
200
Lamp
Description
MS 200W/H75/T15/PS/740
Product
No.
70764
ANSI
Code
M136/E
Initial Lumens Mean Avg. Life
Lumens Per WattLumens Hours
19000
95 15200 15000
250
MS 250W/H75/T15/PS/740
57625
M153/E
22000
88
17600
15000
4000
68
Clear HOR±75°
D
12 29
320
MS 320W/H75/T15/L/PS/740
79710
M154/E
30000
94
24000 20000+
4000
68
Clear HOR±75°
E
12 31
320
MS 320W/H75/T15/S/PS/740
57626
M154/E
30000
94
24000 20000+
4000
68
Clear HOR±75°
D
12 31
350
MS 350W/H75/T15/PS/740
93749
M131/E
33000
94
26000 20000+
4000
68
Clear HOR±75°
E
12 33
1000 MS 1000W/HOR/T25/PS/734* 49111 M141/E
* Permitted rotation about horizontal lamp axis ±15Ëš.
110000
110 77000
3400
68
Clear HOR±45°
F
6
Dia. = 1 7/8” (46mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
A1 = EP39 (POMB)
Dia. = 1 7/8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E39
B1 = EP39 (POMB)
C
D
E
T15
T15
T15
B
T15
A
5000
Oper.
CaseBallast
CRI Finish
Pos.
Fig. QtyRef. Pg.
68 Clear HOR±75° C 12 28
T15
It is energy-efficient to turn off
a fluorescent light only if it
will not be used again within
an hour or more. This is
because of the high voltage
needed to turn it on, and the
shortened life this high
voltage causes.
CCT
(K)
4000
CaseBallast
Fig. Qty Ref.Pg.
A 12 56
U
Enclosed Rated PULSE START LAMPS ANSI Type-E UNI-FORM
Fun Facts
Dia. = 1 7/8” (46mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 1 7/8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E39
F
T25
Specialty
Lamps
Initial Lumens Mean Avg. Life
Lumens Per WattLumens Hours
14000
80 9100 10000
Dia. = 3 1/8” (79mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
50
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Dia. = 1 7/8” (46mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
38
Double Ended & G12
SPECIALTY METAL HALIDE LAMPS
Enclosed Rated PULSE START* SINGLE ENDED LAMPS (G12) ANSI Type-E
Lamp
Description
HIT 70W/G12/UVS/3K
Product
No.
12108
ANSI
Initial Lumens Mean Avg. Life CCT
Code
Lumens Per Watt Lumens Hours
(K)
M85/M98/E 5600
75
3600 10000 3000
CRI Finish
70 Clear
Operating
Case
Pos.
Fig. Qty
U
A 25
Ballast
Ref. Pg.
23
HIT 70W/G12/UVS/4K
52983
M85/M98/E
5600
75
3600
10000
4200
70
Clear
U
A
25
23
HIT 100W/G12/UVS/4K
89887
M90/E
9000
90
5900
10000
4200
70
Clear
U
A
25
24
HIT 150W/G12/UVS/3K
12106
M81/M102/E 14000
93
10500 10000
3000
70
Clear
U
A
25
26
HIT 150W/G12/UVS/4K
25779
M81/M102/E 14000
93
10500 10000
4200
70
Clear
U
A
25
26
Enclosed Rated PULSE START* DOUBLE ENDED LAMPS RSC (R7s) ANSI Type-E
Applications
Lamp
Description
MH-DE 70W/UVS/3K
Product
No.
16786
ANSI
Initial Lumens Mean Avg. Life CCT
Code
Lumens Per Watt Lumens Hours
(K)
M85/M98/E 5200
69
3400 10000 3000
Operating
Case
CRI Finish
Pos.
Fig. Qty
70 Clear HOR±45° B 25
• Landscape Lighting
MH-DE 70W/UVS/4K
60248
M85/M98/E
5500
70
73
3600
10000
4200
Clear
HOR±45° B
25
Ballast
Ref. Pg.
23
23
MH-DE 70W/UVS/FS/6K
79470
M85/M98/E
4800
64
4100
10000
6500
90
Clear
HOR±45° B
25
23
MH-DE 150W/UVS/3K
11295
M81/M102/E 11250
75
8400
10000
3000
70
Clear
HOR±45° C
25
26
MH-DE 150W/UVS/4K
74756
M81/M102/E 11250
75
8400
10000
4200
70
Clear
HOR±45° C
25
26
MH-DE 150W/UVS/FS/6K
29963
M81/M102/E 11250
75
9600
10000
6500
90
Clear
HOR±45° C
25
26
• Downlighting - Low Ceiling
• Sconce Lighting
Enclosed Rated PULSE START DOUBLE ENDED LAMPS RSC (RX7s), Fc2 ANSI Type-E
Product
No.
84727
ANSI
Code
M80/E
Initial Lumens Mean Avg. Life CCT
Lumens Per Watt Lumens Hours
(K)
20000 80 13000 10000 3000
Operating
Case
CRI Finish
Pos.
Fig. Qty
70 Clear HOR±45° E
25
Ballast
Ref. Pg.
28
MH-DE 250W/UVS/4K/Fc2
72748
M80/E
20000
80
13000 10000
4200
70
Clear
HOR±45° E
25
28
MH-DE 250W/UVS/4K/RSC
22468
M80/E
20000
80
13000 10000
4200
70
Clear
HOR±45° D
25
28
* UNI-FORM ® T E C H N O L O G Y
Dia. = 23mm
MOL = 110mm
LCL = 56mm
Base = G12
Contact to Contact = 114.2mm
Base = RSC (R7s)
Contact to Contact = 132mm
Base = RSC (R7s)
It is energy-efficient to turn off
a fluorescent light only if it
will not be used again within
an hour or more. This is
because of the high voltage
needed to turn it on, and the
shortened life this high
voltage causes.
MOL = 163.7mm
Base = RSC (RX7s)
MH-DE
E
MH-DE
D
MH-DE
C
MH-DE
B
G12
A
Fun Facts
MOL = 163mm
Base = Fc2
EUROPEAN USAGE:
70, 100, 150, 250 watt lamps operate on HPS ballasts with MH ignitors
51
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Specialty
Lamps
Lamp
Description
MH-DE 250W/UVS/3K/Fc2
High Watt Double Ended
SPECIALTY METAL HALIDE LAMPS
Enclosed Rated PULSE START LAMPS ANSI Type-F M___/F
Watt
1000
Lamp
Description
MBIL S 1000W
Product
No.
22417*
ANSI
Initial Lumens
Code
Lumens Per Watt
M__/F** 80000
80
Mean Avg. Life CCT
Lumens Hours (K)
64000 6000 5200
CRI
65
Finish
Frosted
Operating
Position
HOR±15°
Fig.
A
Case
Qty
6
1500
MBIL S 1500W
22151*
M__/F** 130000
87
104000
6000
5200
65
Frosted
HOR±15°
B
6
2000
MBIL S 2000W
22132*
M__/F** 215000*** 100
172000
6000
5200
65
Frosted
HOR±15°
C
2
* Approved ballasts are 1000W - M141, 1500W - M133 or M48 with an ignitor, 2000W - M134
** F - ANSI code for lamps which must be used in enclosed luminaires with UV attenuating lenses.
WARNING: Do not operate this lamp if the lens is broken or missing since the unattenuated UV from this lamp can cause serious skin burn and eye
inflammation.
Applications
• Site Lighting
***MBIL 2000 watt lamps are measured at 2150 watts.
• Sports and Recreation
Lighting
European Usage:
High Wattage Double Ended Lamps operate on reactor ballasts with MH ignitors.
MAGNETIC BALLASTS 60Hz
Input
Product ANSI Circuit Input
Max. Line
UL Coil Wiring
Dimensions Wt. Total Cap. Cap. Cap. Ign.Max.Dist.
Watts
Voltage
No.
Code Type Watts
Current
Rise Code Diag. Fig. A (in) B (in) (lbs)(µfd/Vmin) Fig. Type Fig. (ft)
1000 120/208/240/277 V90D7810 M141 CWA 1080 9.00/5.20/4.50/3.90 D/A/B/B E 1 2.8 4.8 21 24/480 B12 Oil F 10
1000 120/208/240/277 V90D7811 M141 CWA 1080 8.95/5.55/4.55/3.95 D/D/C/D
1000
120/277/347 V90J7810 M141 CWA 1080
480/120T
V90Y7810T M141 CWA 1080
1000
480/120T
V90Y7811T M141 CWA 1085
2000
480
V90Y6810 M134 CWA 2150
1 2.8 4.95 18.5 24/480
CWA
6.00"
(152 mm)
K
1 2.93 4.95 21.5 24/480
B12
Oil
F
10
S1
1 2.82 4.85
B12
Oil
F
10
2.35
E
S1
1 2.8 4.85
21 24/480
B12
Oil
F
10
4.70
E
A
1
44 44/510
B10
Oil
G 12
6
8.2
4.25"
(108 mm)
3.87"
(98 mm)
4.375"
(111 mm)
5.375"(136 mm)
A B
MBIL S
MOL = 256mm
Effective arc length = 168mm
Base = RSC (RX7s)
HOLES CLEARED
FOR #10 BOLTS
10
D
C
1 4x6 Core
F
D/B/A
MBIL S
MOL = 256mm
Effective arc length = 183mm
Base = RSC (RX7s)
Oil
2.25
B
MBIL S
A
B12
9.00/3.90/3.15
Specialty
Lamps
1000
E
MOL = 311mm
Effective arc length = 191mm
Base = SINGLE CONTACT-SPECIAL
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #40
52
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
21 24/480
Probe Start Metal Halide
STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S
The Best Lamps
Features
HIDirect offers the widest range of standard probe start
metal halide products, including North American and
European style lamps. With over twenty years of
experience, HIDirect’s high quality lamps are used
worldwide.
• Vacuum impregnation for cooler operation of optimized
insulation system
This section provides complete data for North American
medium and mogul base 175W, 250W, 400W, 1000W
1500W and 1650W standard probe start metal halide lamps.
• UL Temp Codes equal to or better than the competition
• User-friendly installation - Color coded wires as well as
printed labels on the wires make for easy installing - just
follow the diagram on each ballast
• The core size to meet your application - same sizes as
competitors in the same ballast type
• Dry capacitors rated up to 100° C
The Right Ballasts
HIDirect offers a wide selection of CWA and CWI probe
start metlal halide ballasts. Products are available in single,
dual, tri and quad tap ballasts to cover the lighting voltages
of 120V, 208V, 240V, 277V, 347V and 480V.
• Flexibility: Order kits, prewired ballasts, brackets - all in
the configuration that you need
• Thermally protected ballasts available for most pulse start
metal halide ballasts
All ballast specifications are in compliance with North
American and international safety, performance and design
standards, including U.L., CSA and ANSI. In Europe, all
products carry the CE mark, and many of our products
carry approval marks, including ENEC, Kitemark and VDE.
Probe Start
MH Systems
Magnetic
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
53
Probe Start Metal Halide
STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O
Lamp
Watts Description
175 MPI 175W/BU
Product
No.
32519
175
MPI 175W/C/BU
250
MPI 250W/BU
250
MP1 250W/C/BU
Shield®
ANSI
Code
M57/O
Initial Lumens Mean Avg. Life
Lumens Per Watt Lumens Hours
14000
80
9100 10000
CCT
(K)
4000
CRI
65
Finish
Clear
Operation
Position
BU±15°
Fig.
C
Case
Qty
12
32520
M57/0
13300
76
8600
10000
3700
70
Coated
BU±15°
C
12
60722
M58/O
21800
87
14200
10000
4000
65
Clear
BU±15°
C
12
60723
M58/0
20700
83
13500
10000
3700
70
Clear
BU±15°
C
12
Operation
Position
U
Fig.
A
Case
Qty
12
Enclosed Rated LAMPS ANSI Type-E
Features
Lamp
Watts Description
175 MH 175W/U/MED
Product
No.
15556
ANSI
Code
M57/E
Initial Lumens Mean Avg. Life
Lumens Per Watt Lumens Hours
14000
80
9100 10000
CCT
(K)
4000
CRI
65
Finish
Clear
175
MH 175W/C/U/MED
63187
M57/E
13300
76
8600
10000
3700
70
Coated
U
A
12
175
MS 175W/BU/MED
70310
M57/E
15000
86
9800
10000
4000
65
Clear
BU±15°
A
12
175
MS 175W/C/BU/MED/3K
52522
M57/E
13600
78
8800
10000
3200
70
Coated
BU±15°
A
12
175
MH 175W/U
88791
M57/E
14000
80
9100
10000
4000
65
Clear
U
B
12
175
MH 175W/C/U
96627
M57/E
13300
76
8600
10000
3700
70
Coated
U
B
12
175
MH 175W/U/5K
79881
M57/E
12000
69
7800
7500
5000
75
Clear
U
B
12
Applications
175
MS 175W/BU
55087
M57/E
15000
86
9800
10000
4000
65
Clear
BU±15°
B
12
• Floodlighting
• Warehouse
• ParkingGarage
175
MS 175W/C/BU/3K
20981
M57/E
13600
78
8800
10000
3200
70
Coated
BU±15°
B
12
175
MS 175W/HOR*
57330
M57/E
15000
86
9800
10000
4000
65
Clear
HOR±45°
F
12
175
MH 175W/U/T15
40335
M57/E
14000
80
9100
10000
4000
65
Clear
U
K
12
175
MH 175W/U/T15/10K
70136
M57/E
-
-
-
8000
10000
65
Clear
U
K
12
250
MH 250W/U
63052
M58/E
21000
84
13700
10000
4000
65
Clear
U
B
12
250
MH 250W/C/U
61290
M58/E
20000
80
13000
10000
3700
70
Coated
U
B
12
250
MH 250W/U/5K
27252
M58/E
19000
76
12400
7500
5000
75
Clear
U
B
12
Did you know…
250
MS 250W/BU
36297
M58/E
23000
92
15000
10000
4000
65
Clear
BU±15°
B
12
Every time you turn on a light
switch 72% of the energy
comes from coal
250
MS 250W/C/BU/3K
18477
M58/E
20000
80
13000
10000
3200
70
Coated
BU±15°
B
12
250
MS 250W/HOR*
94883
M58/E
23000
92
15000
10000
4000
65
Clear
HOR±45°
F
12
250
MS 250W/HOR/T15/3K*
54843
M58/E
21000
84
13700
10000
3200
65
Clear
HOR±45°
N
12
250
MH 250W/U/T15
33479
M58/E
21000
84
13700
10000
4000
65
Clear
U
K
12
250
MS 250W/HOR/T15*
88353
M58/E
23000
92
15000
10000
4000
65
Clear
HOR±45°
N
12
250
MH 250W/U/T15/10K
63897
M58/E
-
-
-
8000
10000
65
Clear
U
K
12
Probe Start
MH Systems
• Full range of wattages
• Clear and coated versions
• Reduced jacket options
* Permitted rotation about horizontal lamp axis ±15Ëš
54
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EP39 (POMB)
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EX39
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
ED37
H
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
BT37
E
ED37
ED28
Dia. = 3 1/2” (90mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
G
ED28
F
D
BT37
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 3/8” (86mm)
Base = E26
C
ED28
B
ED17
A
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EX39
Probe Start Metal Halide
STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S
featuring UV
Open Rated LAMPS ANSI Type-O
Shield®
Lamp
Watts Description
400 MPI 400W/BU
Product
No.
95527
ANSI
Code
M59/O
Initial Lumens Mean Avg. Life
Lumens Per Watt Lumens Hours
40000
100
26000 20000
CCT
(K)
4000
CRI
65
Finish
Clear
Operation
Position
BU±15°
Fig.
E
Case
Qty
6
400
26091
M59/O
38000
3700
70
Coated
BU±15°
E
6
MPI 400W/C/BU
95
25000
20000
Enclosed Rated LAMPS ANSI Type-E
Product
No.
57540
ANSI
Code
M59/E
Initial Lumens Mean Avg. Life
Lumens Per Watt Lumens Hours
36000
90
23000 20000
CCT
(K)
4000
CRI
65
Finish
Clear
Operation
Position
U
Fig.
B
Case
Qty
12
400
MH 400W/C/U/ED28
20753
M59/E
34000
85
22000
20000
3700
70
Coated
U
B
12
400
MS 400W/BU/ED28
40013
M59/E
40000
100
26000
20000
4000
65
Clear
BU±15°
B
12
400
MH 400W/U/ED28/10K
27540
M59/E
-
-
-
8000
10000
65
Clear
U
B
12
400
MS 400W/HOR/ED28*
21929
M59/E
40000
100
26000
20000
4000
65
Clear
HOR±45°
F
12
400
MS 400W/C/HOR/ED28*
24573
M59/E
38000
95
24000
20000
3700
70
Coated HOR±45°
F
12
400
MH 400W/U
18520
M59/E
36000
90
23000
20000
4000
65
Clear
U
D
6
400
MH 400W/C/U
83545
M59/E
34000
85
22000
20000
3700
70
Coated
U
D
6
400
MH 400W/U/5K
36813
M59/E
32500
81
21000
15000
5000
75
Clear
U
D
6
400
MS 400W/HOR*
40509
M59/E
40000
100
26000
20000
4000
65
Clear
HOR±45°
G
6
400
MS 400W/C/HOR*
64648
M59/E
38000
95
24000
20000
3700
70
Coated HOR±45°
G
6
400
MS 400W/HOR/T15*
55100
M59/E
40000
100
26000
15000
4000
65
Clear
O
12
400
MH 400W/U/T15
55422
M59/E
36000
90
23000
15000
4000
65
Clear
U
L
12
400
MS 400W/HOR/T15/3K*
32225
M59/E
38000
95
24000
15000
3200
65
Clear
HOR±45°
O
12
1000 MH 1000W/U
72051
M47/E
110000
110
71000
12000
4000
65
Clear
U
I
6
1000 MH 1000W/C/U
88460
M47/E
105000
105
68000
12000
3700
70
Coated
U
I
6
1000 MH 1000W/U/5K
35914
M47/E
80000
80
52000
9000
5000
75
Clear
U
I
6
1000 MH 1000W/U/BT37
15332
M47/E
110000
110
71000
12000
4000
65
Clear
U
J
6
1000 MS 1000W/BU
89113
M47/E
115000
115
74000
12000
4000
65
Clear
BU±15°
I
6
1000 MS 1000W/BU/BT37
13090
M47/E
115000
115
74000
12000
4000
65
Clear
BU±15°
J
6
1000 MS 1000W/HOR/BT37/3K*
53702
M47/E
115000
115
86000
12000
3400
70
Clear
HOR±45°
H
6
1000 MS 1000W/HOR/SPORT 60
47503
M47/E
115000
115
86000
12000
3400
70
Clear
HOR±60°
M
6
1000 MS 1000W/BU/T25
78952
M47/E
110000
110
66000
5000
4000
65
Clear
BU±15°
P
6
1500 MH 1500W/HBU
18360
M48/E 161000BU 107
136000BU 3000BU/H
3400
65
Clear
BU±105°
I
6
1500 MH 1500W/U/XL
12342
M48/E 170000V
113
136000V 6000V
4000
65
Clear
U
I
6
M48/E
162000
108
137700
3000
3400
70
Clear
HOR±60°
M
6
1650 MS 1650W/HOR/XP/SPORT 60 16419 M112/E 177000
* Permitted rotation about horizontal lamp axis ±15Ëš
107
145000
3000
3200
70
Clear
HOR±60°
M
6
K
Dia. = 7” (180mm)
MOL = 15 3/8” (391mm)
LCL = 9 1/2” (241mm)
Base = E39
Dia. = 7” (180mm)
MOL = 15 3/8” (391mm)
LCL = 9 1/2” (241mm)
Base = EP39 (POMB)
• Architectural Downlighting
• Site Lighting
Fun Facts
It is energy-efficient to turn off
a fluorescent light only if it
will not be used again within
an hour or more. This is
because of the high voltage
needed to turn it on, and the
shortened life this high
voltage causes.
T15
Dia. = 1 7⁄8” (46mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = E39
Dia. = 1 7⁄8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E39
P
T15
O
T15
N
BT56
M
Dia. = 4 5/8” (120mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = E39
Applications
L
T15
BT37
J
BT56
I
• Reduced jacket options
• Burn positions include
universal, horizontal and
vertical
Dia. = 1 7⁄8” (46mm)
MOL = 8 5/16” (211mm)
LCL = 5” (127mm)
Base = EP39 (POMB)
Dia. = 1 7⁄8” (46mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = EP39 (POMB)
T25
1500 MS 1500W/HOR/XP/SPORT 60 82070
HOR±45°
Features
Probe Start
MH Systems
Lamp
Watts Description
400 MH 400W/U/ED28
Dia. = 3 1/8” (79mm)
MOL = 11 1/2” (292mm)
LCL = 7” (178mm)
Base = EP39 (POMB)
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
55
Probe Start Metal Halide
STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S
MAGNETIC BALLASTS 60Hz
Watts
175
Input
Voltage
120
Product ANSI Circuit Input
No.
Code Type Watts
V90B6112 M57 CWA 206
Max. Line
Current
1.85
175
480
V90Y6111T M57 CWA 211
0.45
B
V1
1
2.22
3.6
6.8
175
600
V90Z6150 M57
0.40
D
O
1
2.65
4.13
9
H
1
2.22
3.6
CWI
226
UL Coil Wiring
Dimensions Total Wt. Capacitor Cap.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig.
C
B
1
2.4 3.8 6.6 10/400 A11
175
120/208/240/277 V90D6111 M57 CWA 210 1.80/1.10/0.90/0.80 C/D/D/C
175
120/208/240/277 V90D6112 M57 CWA 215 1.85/1.10/0.90/0.80 B/C/C/B
Oil
6.8
10/400 A11
Dry
Dry
H
1
2.4
3.8
7
10/400 A11
W
1
2.65
4.13
9
9/520
V90J6111 M57 CWA 210
1.80/0.80/0.65
B/B/C
M
1
2.22
3.6
V90J6112 M57 CWA 210
1.90/0.80/0.65
C/D/D
M
1
2.4
3.8
C
O
1
2.65
4.13
9
B5
Oil
D
V1
1
3
4.4
9.1
15/360 A12
Dry
175
120/277/347
• Signage
175
120/277/347
• Canopies
175
208/120T
226
1.10
• Industrial
250
480
V90Y6211 M58 CWA 288
0.60
600
V90Z6250 M58
0.50
D
V90E6150 M57
V90P6150T M57
CWI
225
CWI
CWI
303
B5
Oil
6.8
10/400 A11
Dry
7
10/400 A11
Dry
9/520
O
2
2.16
3.75
14
12/480
B8
Oil
250
120/208/240/277 V90D6211 M58 CWA 291 2.60/1.45/1.30/1.10 B/A/C/B
H
1
2.8
4.2
8.5
15/360 A12
Dry
250
120/208/240/277 V90D6212 M58 CWA 289 2.50/1.45/1.25/1.10 B/B/B/B
H
2
1.65
3.25
9.3
15/400 A12
Dry
250
120/208/240/277 V90D6215 M58 CWA 290 2.60/1.50/1.30/1.15 A/A/A/A
Dry
H
2
1.46
3.3
8.3
15/400 A12
2.60/1.30
A/A
W
2
2.16
3.75
14
12/480
B8
Oil
V90J6211 M58 CWA 293
2.50/1.10/0.90
A/D/C
M
1
2.8
4.2
8.5
15/360 A12
Dry
V90J6212 M58 CWA 289
2.50/1.10/0.90
A/A/A
M
2
1.65
3.3
9.3
15/360 A12
Dry
A
P
2
2.16
3.75
14
12/480
B8
Oil
B
V1
2
1.55
3.35
8.8
15/400 A12
Dry
250
120/240
V90E6250 M58
250
120/277/347
250
120/277/347
250
208/120T
V90P6250T M58
303
1.50
250
480/120T
V90Y6212T M58 CWA 295
0.60
CWA/CWI
1 3x4 Core
3.94" (100mm)
2.44"
(62 mm)
CWI
303
CWI
Ballast Options
2 4x4 Core
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
A B
CWA/CWI
Probe Start
MH Systems
Dry
B5
B/B
120/240
250
9/520
1.90/0.95
175
Applications
10/400 A11
Cap.
Type
Dry
4.75" (121 mm)
3.87"
(98 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
56
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #58
Probe Start Metal Halide
STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S
MAGNETIC BALLASTS 60Hz
Input
Voltage
600
Watts
400
Product ANSI Circuit Input
No.
Code Type Watts
V90Z6450T M59 CWI 475
Max. Line
Current
0.80
UL Coil Wiring
Dimensions Total Wt. Capacitor Cap.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig.
C
O
1
3.5 5.5
21 19.5/520 B12
Cap.
Type
Oil
400
120/208/240/277 V90D6413 M59 CWA 455 4.00/2.30/2.00/1.75 D/D/E/E
H
1
2
3.9
10.7
24/360 A13
400
120/208/240/277 V90D6414 M59 CWA 455 3.95/2.30/2.00/1.75 D/D/E/E
H
1
2
3.9
10.7
24/360 A13
Dry
400
120/208/240/277
H
1
2
3.9
11.7
24/360 B13
Dry
V90D6412 M59 CWA 452 4.00/2.30/2.00/1.75 C/D/D/D
400
120/240
400
120/277/347
V90E6450 M59
CWI
475
400
208/120T
V90P6450T M59
400
480/120T
1000
208
V90P6550T M47
CWI 1100
5.70
1000
600
V90Z6550 M47
CWI 1100
2.00
Dry
4.05/2.05
B/B
W
1
3.5
5.5
21
19.5/520 B12
Oil
4.00/1.75/1.40
C/E/E
M
1
2.15
3.9
11.4
24/360 A13
Dry
475
2.35
C
P
1
3.5
5.5
21
19.5/520 B12
Oil
Features
V90Y6413T M59 CWA 457
1.00
E
V1
1
2.15
4.1
11.5
24/360 A13
Dry
C
P
2
4.5
6
31
24/480 B12
Oil
• North American and
European styles
B
O
2
4.5
6
31
24/480 B12
Oil
1000 120/208/240/277 V90D6514 M47 CWA 1080 9.00/5.20/4.50/3.90 D/A/A/A
H
2
2.8
4.8
20.5
24/480 B12
Oil
1000 120/208/240/277 V90D6516 M47 CWA 1085 8.80/5.00/4.60/3.90 D/A/B/C
H
1
3.25
5.45
18.5
24/450 B12
Oil
1000 120/208/240/277 V90D6517 M47 CWA 1085 9.00/5.50/4.60/4.00 D/D/C/C
H
2
2.8
4.95
18.5
24/480 B12
Oil
Applications
1000
120/240
F/F
W
2
4.5
6
31
24/480 B12
Oil
• Big Box Retail
1000
120/277/347
D/B/A
M
2
2.9
4.95
21.5
24/480 B12
Oil
• Security
1000
480/120T
V90Y6514T M47 CWA 1080
2.25
C
V1
2
2.82
4.85
21
24/480 B12
Oil
• Industrial
1000
480/120T
V90Y6517T M47 CWA 1085
2.30
D
V1
2
2.8
4.9
18.5
24/480 B12
Oil
1500
480
V90Y6612T M48 CWA 1605
3.40
E
V90J6413 M59 CWA 455
V90E6550 M47
CWI
CWI 1100
10.00/5.00
V90J6514 M47 CWA 1080 9.00/3.90/3.15
V1
2
4.2
6.2
31
32/525 B14
Oil
1500 120/208/240/277 V90D6612 M48 CWA 1625 13.40/7.75/6.70/5.80 G/E/E/E
H
2
4.1
6.1
31
32/525 B14
Oil
1650
120/208/240
V90C6910 M112 CWA 1760 16.40/9.45/8.20
F/D/C
D
2
4.5
6.55
32.1 (2X) 32/570 B9
Oil
1650
277/347/480
V90AA6910 M112 CWA 1760 7.00/5.60/4.00
E/F/H
J
2
4.5
6.6
32.1 (2X) 32/570 B9
Oil
3.87"
(98 mm)
Ballast Options
2 4x6 Core
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
CWA/CWI
CWA/CWI
4.75" (121 mm)
6.00"
(152 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
3.87"
(98 mm)
Probe Start
MH Systems
1 4x4 Core
4.375"
(111 mm)
5.375"(136 mm)
A B
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #58
57
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Wiring Diagrams
STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S
Wiring Diagrams
Probe Start
MH Systems
Wiring diagrams for all of HIDirect’s probe start standard
metal halide ballast products are provided on this page. The
ballast data tables indicate the reference letter
corresponding to the correct diagram for each ballast
product. Refer to the table for the required ballast before
referencing any diagram.
The wiring diagram is the blueprint for the ballast circuitry,
including the input supply voltage and grounding methods.
A ground connection must be made to all ballasts to avoid
shock hazard, personal injury or damage to the luminaire
or installation. Ballast installations and groundings should
be made in accordance with all applicable government
codes and regulations where required.
B
D
H
J
M
O
P
W
V1
58
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
HPS Lamps
HIGH PRESSURE SODIUM LAMPS
AND
BALLASTS
HIGH PRESSURE SODIUM LAMPS
Wattage
70W
Lamp
Description
HPS070/U CLEAR
Product
No.
84762
ANSI
CODE
S62
Initial
Lumens
6000
Avg. Life
Hours
24000+
CCT
(K)
2100
Fig.
B
S62
6400
24000+
1900
A
25472
S54
9500
24000+
2000
B
100W
LU 100/MED
69456
S54
9500
24000+
2000
A
100W
HPS100/U/MED CLEAR
69457
S54
9000
24000+
2100
A
150W
LU 150/55
64616
S55
16000
24000+
2000
B
150W
HPS150/U/MED CLEAR
28639
S55
15000
24000+
2100
A
250W
LU 250
35946
S50
28000
24000+
2100
C
400W
LU 400
17934
S51
51000
24000+
2100
C
1000W
HPS1000/U CLEAR
86346
S52
140000
24000+
2100
D
Dia. = 2 1/8” (54mm)
MOL = 5 7/16” (138mm)
LCL = 3 7/16” (87mm)
Base = E26
B
C
D
Dia. = 2 15/16” (75mm)
MOL = 7 3/4” (197mm)
LCL = 5” (127mm)
Base = E40
Dia. = 2 1/4” (57mm)
MOL = 9 3/4” (248mm)
LCL = 5 3/4” (146mm)
Base = E40
HPS Lamps
and Ballasts
ED17
A
ET25
51918
LU 100
ED18
LU 70/MED
100W
ED23.5
70W
Dia. = 3 1/8” (79mm)
MOL = 15 1/16” (383mm)
LCL = 8 3/4” (222mm)
Base = E40
59
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
HPS Ballasts
HIGH PRESSURE SODIUM LAMPS
AND
BALLASTS
HIGH PRESSURE SODIUM BALLASTS 60Hz
Watts
35
Applications
Input
Voltage
120
Product ANSI Circuit Input
No.
Code Type Watts
V90B1020 S76 R-NPF 45
Max. Line
Current
0.85
UL Coil Wiring
Dimensions Total Wt.Total Cap. Cap. Cap. Ign.Max.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig.Dist.(ft)
A
U1 1
0.9 2.15 2
- N/A D 2
35
120
V90B1020C S76 R-HPF 45
0.75
A
U1
1
0.9
2.15
2
16/120 A7 Dry D 2
35
347
V90V1030 S76 HX-HPF 54
0.30
A
X
3
0.7
2
4
4.5/280 B1
Oil
D 3
35
120/240
V90E1030 S76 HX-HPF 54
0.80/0.40
D/C
Z
3
0.67
2
4
4.5/280 B1
Oil
D 3
50
120
V90B1120 S68 R-NPF 65
1.20
A
U1
1
1.15 2.35
2
50
120
V90B1120C S68 R-HPF 65
1.00
A
U1
1
1.15 2.35
2 22.5/120 A2 Dry D 2
-
-
N/A D 2
347
V90V1131 S68 HX-HPF 75
0.40
D
X
3
0.8
2
4
6/330
A5 Dry D 2
50
120/240
V90E1131 S68 HX-HPF 76
1.20/0.60
F/F
Z
3
0.8
2
4
6/330
A5 Dry D 2
• Architectural Lighting
50
120/240
V90E1151 S68
73
0.65/0.35
A/A
V
3
1
2.25
5
17/340 B4
50
120/277
V90H1132 S68 HX-HPF 66
1.00/0.45
A
Q1
3
1
2.4 3.6
70
120
V90B1222 S62 R-NPF 85
1.65
B
U1
2
1.29
2.2
3
70
120
V90B1222C S62 R-HPF 85
1.25
B
U1
2
1.29
2.2
3
28/120 A3 Dry D 2
70
600
V90Z1252 S62
0.15
A
N
3
1.65 3.25
6
24/330 A2 Dry
CWI
CWI
96
-
2.95 4.6
7/280
Oil
E 2
A1 Dry D 5
-
N/A D 2
E 2
3
1.5
70
120/240
V90E1250 S62
CWI
83
0.75/0.40
A/A
V
3
2.15 3.15
8
26/280 A2 Dry
E 2
70
120/240
V90E1252 S62
CWI
96
0.85/0.40
A/A
U
3
1.65 3.25
6
24/330 A2 Dry
E 2
70
120/277/347
A5 Dry D 5
D/D/D A1
3
1.1
2.13
4
9/330
100
100
V90J1232 S62 HX-HPF 91
1.50/0.65/0.55
120
V90B1322 S54 R-NPF 118
2.15
E
U1
3
1.5
2.4
3
120
V90B1322C S54 R-HPF 118
1.80
E
U1
3
1.5
2.4
3
40/120 A3 Dry D 2
100
600
V90Z1352 S54
CWI 132
0.25
D
N
3
2.15 3.15
8
35/280 A2 Dry
E 5
100
120/208/240
V90C1353 S54
CWI 130
1.15/0.70/0.60
B/AA
T
3
2.15
3.5 6.7 35/180 A2 Dry
E 5
100 120/208/240/277 V90D1333 S54 HX-HPF 126 2.10/1.20/1.05/0.90A/A/A/A Y
3
2
100
120/240
100
120/277/347
150
150
V90E1350 S54
CWI 121
-
A5 Dry D 2
-
N/A D 2
3.45 5.9 10/280 A6 Dry D 5
1.10/0.55
A/A
V
3
2.5
3.5
9
42/280 A3 Dry
V90J1332 S54 HX-HPF 127
1.85/0.85/0.65
C/C/C
A1
3
2.32
3.7
8
9/290
120
V90B1422 S55 R-NPF 166
3.20
E
U1
2
2
2.95
4
120
V90B1422C S55 R-HPF 166
2.35
E
U1
2
2
2.95
4
150
480
V90Y1454 S55
CWI 186
0.40
D
N
3
3.15 4.55 11
51/180 A4 Dry
E 3
150
120/208/240
V90C1454 S55
CWI 185
1.70/1.00/0.85
B/A/A
T
3
3.15
4.6 9.5 51/180 A4 Dry
E 5
150 120/208/240/277 V90D1435 S55 HX-HPF 188 2.80/1.60/1.40/1.25 D/B/C/C Y
3
2.5
3.8 7.4 14/280 A1 Dry D 5
3.95
3
2.5
347/120T
V90V1454T S55
CWI 186
0.60
B
A2
3
3.15 4.55 11
51/280 A4 Dry
E 2
150
600/120T
V90Z1454T S55
CWI 186
0.35
C
A2
3
3.15 4.55 11
51/280 A4 Dry
E 2
REACTOR
2 7/8 in Core
HOLES CLEARED
FOR # 6 BOLTS
1.88"
(48 mm)
1.5"
(38 mm)
D/B/C A1
N/A D 2
120/277/347
2.25"
(57mm)
3.15/1.30/1.10
-
52/120 A4 Dry D 2
150
1.88"
(48mm)
A B
2.625"
(67mm)
2.188"
(56 mm)
1.75"
(45 mm)
8 13.5/290 A1 Dry D 2
3 3x4 Core
HOLES CLEARED
FOR # 6 BOLTS
2.189"
(56mm)
A B
CWI/HX
V90J1434 S55 HX-HPF 195
-
E 2
A5 Dry D 2
150
1 3/4 in Core
3.94" (100mm)
2.44"
(62 mm)
HOLES CLEARED
FOR #8 BOLTS
2.84"
(72 mm)
3.50" (89 mm)
Ballast Options
60
5/280
70 120/208/240/277 V90D1233 S62 HX-HPF 90 1.50/0.85/0.75/0.65 A/A/A/A Y
REACTOR
HPS Lamps
and Ballasts
50
• Street Lighting
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #62
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
A B
HPS Ballasts
HIGH PRESSURE SODIUM LAMPS
BALLASTS
AND
HIGH PRESSURE SODIUM BALLASTS 60Hz
Watts
200
Input
Voltage
347
200
120/240
Product ANSI Circuit Input
No.
Code Type Watts
V90V1650 S66 CWI 241
Max. Line
Current
0.75
V90E1650 S66
2.05/1.05
V
1
1.33
3
250 120/208/240/277 V90D1711 S50
CWA 295 2.50/1.45/1.25/1.10B/B/B/B E
1
1.8
3.6
250
120/240
V90E1750 S50
CWI 300
2.55/1.30
F/F
V
1
1.65 3.75 12
28/330 A3 Dry
250
120/277/347
V90J1711 S50
CWA 295
2.70/1.15/0.95
B/A/B
K
1
1.8
3.6
11
35/240 A2 Dry D 2
250
480/120T
V90Y1711T S50
CWA 305
0.65
B
S1
1
1.8
3.6
11
250
600/347
V90AS1750 S50
CWI 300
0.90/0.50
C/E
Z1
1
1.65 3.75 12
28/330 A3 Dry
CWA 460 3.80/2.20/1.90/1.70 C/C/D/C E
1
2.3
4.2
14
55/240 A4 Dry D 2
400 120/208/240/277 V90D1912 S51
CWI 241
UL Coil Wiring
Dimensions Total Wt.Total Cap. Cap. Cap. Ign.Max.
Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig.Dist.(ft)
F
N
1 1.33 3 10 22.5/330 A2 Dry E 2
D/D
10 22.5/330 A2 Dry
11
E 2
35/240 A2 Dry D 2
E 2
35/240 A2 Dry D 2
E 2
400
120/240
V90E1950 S51
CWI 470
4.05/2.05
F/F
V
1
2.45
4.1
16
45/330 A4 Dry
400
120/277/347
V90J1911 S51
CWA 460
3.80/1.70/1.30
C/C/D
K
1
2.3
4.2
14
55/240 A4 Dry D 2
400
208/120T
V90P1950T S51
CWI 470
2.35
D
A2
1
2.45
4.1
16
45/330 A4 Dry
E 2
400
600/347
V90AS1950 S50
CWI 450
1.40/0.80
D/H
Z1
1
2.45
4.3
12
45/270 A4 Dry
E 2
400
480/120T
V90Y1912T S51
CWA 464
1.00
C
S1
1
2.6
4.45 15
430
120/208/240
4.55/2.65/2.25
B/B/A
55/240 A4 Dry D 2
T
1
2.6
4.5 15.7 45/260 A4 Dry
600 120/208/277/480 V90D2111 S106 CWA 695 5.90/3.40/2.95/2.55A/A/A/A Y1
2
3.4
5.4 24.5 59/300 A14 Dry
1000
N
2
5.5
7.25 40
22/660 B15 Oil
F 2
1000 120/208/240/277 V90D2310 S52
CWA 1065 8.95/5.00/4.50/3.90 C/C/C/C E
2
3.8
5.9 27.5 26/480 B12 Oil
F 5
1000 120/208/240/277 V90D2311 S52
CWA 1100 9.50/5.50/4.75/4.20 C/B/C/C E
2
3.75
5.9
26/525 B12 Oil
F 5
1000 120/208/240/277 V90D2315 S52
CWA 1065 9.25/5.15/4.75/4.05 C/C/C/C E
2
3.8
5.9 25.5 26/480 B12 Oil
F 5
1000
V90E2353 S52
CWI 1095
9.50/4.75
A/C
V
2
5.5
7.25 40
1000 120/277/347
V90J2310 S52
CWA 1065
8.95/3.90/3.15
E/E/E
K
2
3.8
1000
V90Y2311T S52
CWA 1100
2.30
C
S1
2
3.9
120/240
480/120T
V90Z2353 S52
4.75" (121 mm)
3.87"
(98 mm)
1.90
A
27
E 2
15
22/660 B15 Oil
F 2
26/480 B12 Oil
F 5
5.9 28.8 26/525 B12 Oil
F 2
6
28
2 4x6 Core
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
4.37" (111 mm)
A B
6.00"
(152 mm)
HOLES CLEARED
FOR #10 BOLTS
4.25"
(108 mm)
3.87"
(98 mm)
4.375"
(111 mm)
5.375"(136 mm)
HPS Lamps
and Ballasts
CWA/CWI
1 4x4 Core
CWI 1095
CWA/CWI
600
V90C2050 S145 CWI 492
E 2
A B
Ballast Options
Add Suffix for Options:
C - With Capacitor (Standard)
K - With Capacitor and Bracket Kit
B - With Welded Bracket, No Cap
Ballast Bracket and Kit Figures
are located on Page #69
Capacitor and Ignitor Figures
are located on Page #68
Wiring Diagrams are located on
Page #62
61
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
HPS Ballasts
HIGH PRESSURE SODIUM LAMPS
AND
BALLASTS
Wiring Diagrams
HPS Lamps
and Ballasts
Wiring diagrams for all HIDirect’s HPS ballast products are
provided on this page. The ballast data tables indicate the
reference letter corresponding to the correct diagram for
each ballast product. Refer to the table for the required
ballast before referencing any diagram.
The wiring diagram is the blueprint for the ballast circuitry,
including the input supply voltage and grounding methods.
A ground connection must be made to all ballasts to avoid
shock hazard, personal injury or damage to the luminaire
or installation. Ballast installations and groundings should
be made in accordance with all applicable government
codes and regulations where required.
E
K
N
T
U
V
X
Y
Z
A1
Q1
S1
U1
Y1
Z1
A2
62
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Reference Guide
TECHNICAL INFORMATION
Introduction
In order to bring the best quality and service in the HID
lighting industry, we have included in this catalog a
reference guide containing a trouble shooting guide, a
lamp and ballast cross reference and also a glossary of
terms. We hope this information is helpful and will be used
often. When you think of metal halide lamps and ballasts,
think of HIDirect.
Trouble Shooting Guide . . .p 64-65
Replacement Parts . . . . . . . . . .p 66-67
Capacitors Figures . . . . . . . . . . . .p 68
Ignitor Figures . . . . . . . . . . . . . . . . . .p 68
Lamp Shapes and Bases . . . .p 68
Ballast Brackets . . . . . . . . . . . . . . . .p 69
Glossary of Terms . . . . . . . . . .p 70-71
Lamp Cross Reference . . . . .p 72-73
Ballast Cross Reference . . . . . .p 74
Reference
Guide
Reference
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
63
Trouble Shooting Guide
TECHNICAL INFORMATION
#1
How can I distinguish
between lamp failure and
fixture failure?
All HIDirect fixtures shipped from our facility are tested to
operate a compatible lamp. First check to see that you
have the correct wattage lamp that matches the ballasts.
The label affixed to the side of the fixture identifies the
wattage of that specific fixture and the coordinating lamp
and ballast ANSI Codes.
If the lamp does not ignite, replace with a known good
lamp. If that lamp does not operate there may be a
wiring or ballast problem.
#2
What do I need to check
within the system prior to
operation?
Be certain that the lamp you are using is compatible with
the fixture wattage and ANSI code.
#3
What are the dimming wires
that come out of an electronic
fixture?
Dimming wires from the fixture are Orange and Brown.
Please follow the instructions exactly for correct wiring. If
a motion sensor is used, please follow the wiring
diagrams provided by the sensor manufacturer.
The cord coming from the fixture is already wired to the
inside of the ballast and is ready to be utilized. If a
rework of the cord connection for length extension or
compatibility with a specific plug is required, a re-wiring
of the new cord is necessary. Note that the Pink (light red
color) wires are for the lamp connection (which is already
connected to the socket). The Green wire is the ground
wire, Yellow is the low or neutral wire, and the Black is
the high or hot wire. All of these wires are integrated into
our own cord; be certain that you are connecting the plug
correctly to the fixture’s cord. In the case of the use of a
longer cord, please follow the standard wiring diagrams
approved by the lighting industry.
#4
Reference
Guide
What if the lamp will not
start?
1) Check to see if lamp is loose in the socket.
Check for arcing (blackening) at the center contact
button and retighten lamp until it is properly seated.
Tightening too much may cause lamp breakage.
2) No power to ballast: Check circuit breakers or other
causes of potential power outages.
3) Normal end of lamp life: Test operating lamp in
adjacent luminaire. Replace if necessary.
4) Sensing devices: Replace sensing device as needed.
64
5) Defective/improper wiring: Verify fixture has been
properly wired. Correct as needed.
Correct wiring if required.
6) Voltage at luminaire is too low: Line voltage at input of
ballast should be within 10% of label rating (increased
loading/demand decreases available voltage at
ballast primary). Check at full load. If tapped ballast,
match ballast tap connection to supply voltage
measured at ballast. Verify that lamp to ballast
distance is acceptable.
7) Ballast/Lamp: Use a ballast compatible with your
lamp. Ensure ballast and lamp are not defective.
8) Improper lamp operating position: Be certain
operating position agrees with lamp specifications.
9) Hot restrike: When power is cut or interrupted for HID
lamps, they require a cool-down period of up to 20
minutes for “hot restrike” with standard probe start
metal halide systems and 8-12 minutes with
Uni-Form® pulse start systems.
Verify ignitor pulse is present.
#5
What if the lamp life is
reduced?
1) Lamp compatibility: Check that the lamp is the correct
wattage and ANSI Code.
2) Lamp damaged: Visually check interior and exterior
bulb, arc tube and base for defects.
3) Ballast: Make certain that the ballast label agrees with
the line voltage and lamp.
4) Lamp in incorrect position: Replace incorrect lamp
with suitable lamp in proper position.
#6
What if lamp flickers or
cycles?
1) Check the photocell (if applicable): If a photocell is
used to switch the fixture, cover the photocell window
or eye completely with black electrical tape and check
for proper operation.
A. If the cycling STOPS, re-aim the photocell (or the
fixture) to reduce fixture light spill onto the
photocell eye.
B. If the cycling CONTINUES, replace the photocell
with a shortening cap if available or bypass the
photocell completely in the circuit temporarily. If the
lamp remains on the photocell is defective. If the
cycling STILL CONTINUES, the lamp is probably
bad.
2) Wrong ballast: New lamps may “cycle.” If lamp
doesn’t stabilize after 3 starts or after 30-60 sec.
intervals, check ballast.
Measure lamp operating voltage. Measure ballast open
circuit voltage. Replace as necessary.
3) Variable voltage: Other machinery on lighting circuits
may cause flickering. Remove lighting circuits from
those serving these devices. Provide voltage
regulators.
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Trouble Shooting Guide
TECHNICAL INFORMATION
#7
#11
1) Hard starter: If lamp doesn’t ignite rapidly, check
voltage and ballast. Replace if necessary.
1) Normal maintenance: Color shift may occur as lamps
age. Using Uni-Form® pulse start systems and/or
group re-lamping will minimize this.
What if the lamp starts
slowly?
#8
What if the fuses are blown
or circuit breakers are open
on lamp start?
What if a difference in lamp
color is noted?
2) Wrong lamp color: Etching on lamps will be different
if lamps are not the same. Replace as needed.
1) Overloaded circuit: Rewire to accommodate starting
open circuit current of lamp and ballast found on lamp
specification sheet.
3) Variations in luminaires: Variations in the surface or
finish of the reflectors and/or lenses can introduce
color differences. Interchange lamps to check for
possible luminaire differences. Make certain that
luminaries are clean.
2) High momentary transient current: Limit amperage by
reducing luminaire quantity to each circuit.
4) Environmental variations: A room’s walls, floors,
furnishings, etc. may affect appearance of lamp color.
#9
Measure capacitance to specification using capacitance
meter. Replace capacitors if needed.
What if the lamp output light
is low?
1) Lamp depreciation: Refer to published technical
characteristics to see if depreciation is within normal
range. The lighting system may be due for a group relamp.
2) Incorrect voltage: Check if rating designation conforms
to lamp rating description. Check line voltage at
ballast and compare to rated voltage requirements.
Look at wiring connections for voltage loss points.
Check socket contact point.
3) Incorrect ballast output: Determine if it conforms to
lamp requirements. If voltage & current don’t stabilize
within 5-10 min. of warm-up time, ballast output is
incorrect & adjustment should be made.
#12
What if the reflector has
changed shape and color?
Verify the reflector meets the following guidelines:
Plastic: Any open optic greater than a 22 inch diameter
and 3570 cubic inch volume.
Glass and Metal: Any open optic greater than a 15 inch
diameter and 1390 cubic inch volume:
Optics specifications are UL requirements based on heat
constraints. Optics may also be referred to as a Reflector,
Reflexor, Refractor etc. by various manufacturers. All of
HIDirect’s fixtures are “Open Rated” only.
4) Dirt accumulation: Regularly clean and maintain your
lamp and luminaire.
#10
What if the arc tube becomes
blackened or swollen?
1) Over-wattage operation/improper ballasting: Check if
lamp is operated on ballast designed for higher
wattages, check ballast label against lamp
specification.
Reference
Guide
2) Reflector problem: If you suspect reflector is refocusing
damaging energy on arc tube, contact luminaire
manufacturer.
3) “Glow state” operation: Under certain conditions,
lamps will go into a partial discharge (dim glow).
Replace lamp and check ballast.
65
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Replacement Parts
TECHNICAL INFORMATION
Lamp Sockets 4KV Rated
Product
No.
Fix.
Req.
Socket
Size
Socket Lead
Color Length
CE001X01R0
Enclosed
Mogul
E39
White
12
All enclosed rated (ANSI Type-E) mogul based
MH and MS lamps excluding POMB horiz. lamps
CE001X03R0
POMB
Mogul
EP39
Yellow
12
Only MS/HOR enclosed rated (ANSI Type-E)
mogul based lamps (e.g. MS 400W/HOR)
CE001X04R0
Open
Mogul
EX39
Pink
12
Accepts only open rated (ANSI Type-O)
MP, MPI and MPSE mogul based lamps
(e.g. MP 400W/V/PS/740 or
MPI 360W/BU/EM)
CE002X04R0
Enclosed
Medium E26
White
9
All enclosed rated (ANSI Type-E) medium based MH and MS lamps
CE002X04R0
Open
Medium EX26
White
12
Only open rated (ANSI Type-O) medium based lamps
About Open Rated
Lamps and Sockets
Description
Open Fixture
Open Rated Lamps
Open fixtures offer significant advantages
over enclosed fixtures. They do not require
cover lenses which reduce light output and
accumulate dirt. Enclosed fixtures make lamp
replacements more difficult. For safety, open
fixtures need open rated (ANSI Type-O) metal
halide lamps.
To reduce the risk of liability, lighting specifiers
need to be aware of the criteria for a true
open rating and what the Type-S or Type-O
designations indicate about lamp construction.
HIDirect’s Type-O
open fixture rated
lamps characteristics:
1. Shroud around the arc tube, which helps
prevent damage to the outer bulb in the
event of an arc tube rupture
Enclosed Fixture
EX26 Socket
Medium
Base
The narrower
EDX17 neck
allows full
insertion into
the socket.
The wider
bulb neck will
not fit past
ceramic neck
of socket.
Mogul
Base
The standard
center contact
won’t reach
the contact in
the dedicated
socket.
The extended
center contact
completes
the circuit
in the socket.
EX39 Socket
2. Open fixture rated base, such as an EX39
mogul base or narrow neck bulb with a
medium base
3. Pass the ANSI C78.389 lamp containment test, where
arc tubes are forcibly ruptured and must be contained
within the outer jacket.
All of HIDirect’s MP, MPSE and MPI lamps meet the
requirements to be rated Type-O, and can be used with
confidence.
Reference
Guide
Open Rated Lamp Benefits
Type-O
EX39 Base
Arc Tube
Shroud
HIDirect’s MP, MPSE and MPI lamps:
• Meet requirements of the 2005 NEC
• Meet ANSI criteria for use in open luminaires
• No luminaire lens required, delivering more light Lumen loss with a lens is up to 16%
• Can be operated continuously, no shut-off required
• Operate in open or enclosed luminaires
• More cost effective than installing a fixture lens
66
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Replacement Parts
TECHNICAL INFORMATION
A full range of HID oil filled and dry film capacitors and
ignitors are available. Call HIDirect customer service for
pricing and availability.
Replacement Capacitors continued
Replacement Ignitors
ACG188
ACG189
ACG200
ACG247
ACG257
ACG263
ACG302
ACG311
ACG312
ACG313
ACG322
ACG324
ACG325
ACG326
ACG004
ACG005
ACG033
ACG160
ACG172
ACG181
ACG206
ACG213
ACG222
ACG226
ACG240
ACG255
ACG258
ACG264
ACG277
ACG279
ACG300
ACG301
ACG303
ACG305
ACG306
ACG307
ACG308
ACG309
ACG310
ACG314
ACG320
ACG321
ACH277
ACH279
Ignitor Part #
BVS004AREPL
BVS005REPL
BVS005AREPL
BVS006REPL
BVS006AREPL
BVS012REPL
BVS016REPL
BVS020REPL
BVS031REPL
BVS032REPL
BVS040REPL
BVS041REPL
BVS042REPL
BVS045REPL
Replacement Capacitors
Capacitor
Number
ACB046OV
ACB070OV
ACB079OV
ACB109OV
ACB111OV
ACB115OV
ACB151OV
ACB159OV
ACB170OV
ACB198OV
ACB201OV
ACB214OV (2)
ACB215OV
ACB220OV
ACB224OV
ACB228OV
ACB232OV
ACB237OV
ACB247OV
ACB256OV
ACB264OV
ACB265OV
ACB266OV
ACB274OV
ACB276OV
ACB277OV
ACB278OV
ACB279OV
ACB282OV
ACB286OV
ACB287OV
ACB288OV
ACB292OV
ACB327OV
ACG148
ACG149
ACG164
ACG183
Description
Capacitance
(Micro-Farads)
VAC
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Oil Cap
Dry Film
Dry Film
Dry Film
Dry Film
4.5
7.5
7
10.5
9
9
10
17
12
11
16
(2x16) 32
24
24
22
19.5
21
15
24
32
26
21
44
22
28
15
26
10
18
18
25
33
32
22
31.2
15.6
8.7
11
660
540
660
520
520
660
400
370
480
660
370
660
660
480
480
520
520
660
400
525
525
410
520
660
480
400
400
400
480
525
400
240
525
525
330
330
330
330
Capacitor
Number
Description
Capacitance
(Micro-Farads)
VAC
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
Dry Film
19
14.5
21.5
24
42
30
52
36
38
15
8
52
59
21
40
52
6
13.5
35
22.5
28
24
45
7
51
55
9
26
15
10
18
16
12.5
20
22
13
10
14
8
5
32
12
15
10
330
330
330
400
280
280
330
280
330
280
330
330
330
400
280
280
330
330
280
330
330
330
330
330
280
300
330
330
400
400
330
330
330
330
330
330
330
330
280
280
330
330
400
400
Ignitors
Oil-filled capacitor
Dry-film capacitor
CAPACITOR NOTES
1. See "INCLUDED CAPACITOR" column in
ballast list for correct capacitor replacement
2. Two capacitors required for V90AA6910C
and V90AA6910K (32 Micro-farads)
Reference
Guide
67
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Capacitors and Ignitors
TECHNICAL INFORMATION
C
IGNITOR– OVAL
DIA
1.97
1.62
1.97
1.97
1.62
1.97
1.62
1.97
1.97
2.03
2.03
1.97
1.97
2.03
2.03
2.03
1.62
WD
2.97
2.75
2.97
2.97
2.75
2.97
2.75
2.97
2.97
3.72
3.72
2.97
2.97
3.72
3.72
3.72
1.32"
(33.5 mm)
1.25 in
2.25 in
.605
.250
.200
YELLOW
.930
1.250
END VIEW
2.16" (55 mm)
F
IGNITOR– OVAL
IGNITOR– OVAL
G
2.06"
(52.3mm)
IGNITOR- BVS-046
H
2.06"
(52.3mm)
2 in
2.45"
(62.2mm)
2 in
3 in
2.30"
(58.4mm)
2.30"
(58.4mm)
1.48"
(37.6mm)
1.16"
(29.5mm)
Lamp Shapes and Bases
Lamps
MBIL S
Double
Ended
MH-DE
Double
Ended
G12
Bi Pin
T12
Tubular
ED17
Elliptical
Dimpled
T15
Tubular
EDX17
Narrow Neck
(open fixture)
ED28
Elliptical Dimpled
T25
Tubular
ED37
Elliptical Dimpled
BT37
Blown Tubular
Reference
Guide
BT56
Blown Tubular
Bases
Bi Pin
Ceramic Base
(G12)
RSC
Recessed
Single Contact
(R7s and RX7s)
Fc2
Ceramic
3.610
2.75
1.48"
(37.6mm)
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
(Inches)
POLARIZED
QUICK DISCONECT
2.315
1.750
1.16"
(29.5mm)
HT
3.00
3.25
3.68
3.37
3.87
4.00
3.37
2.87
4.00
4.94
6.00
4.37
3.87
4.44
4.37
4.37
3.00
WHITE/RED
0.25"
(6.3 mm)
WD
1.38
1.60
1.75
1.75
1.38
1.49
1.49
1.97
1.38
1.49
1.80
1.75
IGNITOR– ROUND
.132
3.50
(88.9mm)
HT
3.93
3.93
3.93
4.88
2.73
2.73
3.93
4.88
2.93
4.88
3.69
4.60
E
2.610
OVAL DIA.
WIDTH
(Inches)
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A13
A14
4.75"(121mm)
4.25" (108 mm)
HEIGHT
WIDTH
IGNITOR– ROUND
1.00"
(25.4 mm)
0.58" (15 mm)
HEIGHT
D
BLUE
CAPACITOR– OIL FILLED
B
3.00"(76mm)
CAPACITOR– DR Y FILM
TOP VIEW
A
MED
Medium Base
(E26)
MOG
Mogul Base
(E39)
Open Fixture
Mogul Base
(EX39)
POMB
Position Oriented
Mogul Base
(EP39)
68
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Ballast Brackets
TECHNICAL INFORMATION
Core & Coil Welded Brackets
These brackets are supplied as an option by adding a
“B” suffix to the ballast product number
1500-2000W
4 x 6 Core T&L
Small Core E&I Reactors
(3/4, 7/8, and 1 in)
A
B
.28"
.75"
1.51"
4.50"
.31"
1.51"
3.19"
4"
6.75"
7.75"
4 x 4, 4 x 6 Core T&L
3.75 x 4.5 Core E&I Reactors
2x400W-1000W
4 x 6 Core T&L
3 x 4 Core T&L
C
D
.28"
1.25"
E
.28"
1"
5.38"
3.98"
6.50"
5.10"
2.75"
.88"
.28"
.88"
6.63"
7.75"
Core & Coil Adjustable
Mounting Brackets
(Included with Capacitor and Bracket Kits)
These brackets, along with appropriate hardware, are
supplied as an option by adding a “K” suffix to the
ballast product number
3 x 4 Core T&L
Small Core E&I Reactors (3/4, 7/8, and 1”)
F
4 x 4, 4 x 6 Core T&L
3.75 x 4.5 Core E&I Reactors
G
.31"
1.19"
1.33"
.28"
4.25"
5.75"
5.50"
7.25"
Core & Coil Adapter Mounting
Bracket Kits
These brackets along with appropriate hardware are
available in kits
H
BCK-016
To mount 1” Core E&I Reactors in
fixtures with a 3 x 4 T&L footprint
3.94"
3.5"
I
4.75"
4.38"
BCK-017
To mount 3.75 x 4.5 Core E&I Reactors
in fixtures with a 4 x 6 T&L footprint
Reference
Guide
BCK-015
To mount 3.75 x 4.5 Core E&I Reactors
in fixtures with a 4 x 4 T&L footprint
6"
5.38"
J
.653"
4.21"
3.75"
3.84"
2.5"
2.44"
4.21" 3.84"
3.84"
3"
4.50"
69
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Glossary of Terms
TECHNICAL INFORMATION
Arc Tube: A completely sealed quartz or ceramic tube
where the electrical discharge (arc) occurs and light is
generated
Ballast: A device that, by means of resistance,
inductance, capacitance or electronic elements, singly or
in combination, controls the current, voltage and
waveform to the required values for proper lamp starting
and operation
Ballast Characteristic Curve: The curve of lamp wattage
vs. lamp voltage over a range of normal lamp voltages
when an HID ballast is operated at a given supply
voltage
Formed Body Arc Tube: Precisely reproducible ellipsoidal
arc tube formed by pressurizing molten quartz inside a
mold; produces consistent arc tubes with higher efficacy
and improved color uniformity
HID: High Intensity Discharge lamps; includes metal
halide, mercury vapor and high pressure sodium
High-Power-Factor (HPF) Ballast: A ballast designed so
that the input power factor is not less than 90% when the
ballast is operated at the rated supply voltage using an
appropriate reference lamp
BTL : The distance from ballast-to-lamp
High Reactance Autotransformer (HX) Ballast: An
autotransformer lag circuit that uses a magnetic shunt
path between primary and secondary coils to control
reactance; has operating characteristics similar to those
of a reactor and has input taps to accept a wide range of
supply voltages
Burning Position: The position or orientation in which a
lamp operates
Hot Restart or Restrike Time: The time from lamp extinction
to lamp re-start after a supply voltage interruption
Cold Start Time: The amount of time from the application
of ballast voltage to ignition of the arc discharge
Ignitor: An electronic device which provides, by itself or
in combination with other circuit components, the
appropriate electrical pulses to start a discharge lamp
Ballast Power Factor: Power consumed by the lamp and
ballast (watts) divided by the product of line voltage and
line current (“volt-amps” or “VA”); A measure of power
quality and of concern to utilities
Color Rendering Index (CRI or Ra): A measure of a light
source’s ability to render colors relative to a standard of
100
Constant Wattage Autotransformer (CWA) Ballast: A
magnetic autotransformer lead ballast circuit
incorporating a capacitor in series with the lamp;
compared to other ballasts, the CWA regulates over a
wider input voltage range, holding lamp current nearly
constant
Constant Wattage Isolated (CWI) Ballast: A magnetic
lead ballast circuit incorporating a fully-isolated
secondary winding; it has a capacitor in series with the
lamp and the same performance features as the CWA
ballast
Correlated Color Temperature (CCT): The perceived
“color” of the light emitted by a lamp expressed in kelvin
(K) units
Current Crest Factor: The ratio of the peak-to-RMS value
of lamp current; metal halide magnetic ballast values
range from 1.5 to 1.8
e-Lamp®: 4000K color temperature pulse start lamps
specifically designed for use on high frequency electronic
ballasts; capable of dimming down to 35% lamp power
Economic Life: The number of hours a group of lamps will
burn before it is economically and aesthetically advisable
to group relamp (typically 60% to 75% of rated life)
Efficacy (Lamp): A ratio of lamp lumens to lamp power
measured in lumens per watt (LPW)
Reference
Guide
Fixture Requirements: Enclosed or open types
Energy Master®: HIDirect’s line of energy-saving retrofit
lamps that operate on existing ballasts at lower wattages
than the original lamps
Extinction Voltage: The RMS value of supply voltage at
which a reference lamp extinguishes when the supply
voltage is slowly reduced from its rated value. The ANSI
procedure calls for a 2 to 3% reduction in supply voltage
per second
Initial Lumens: The light output of a lamp at rated power
on a reference ballast after 100 hours of operation
Input Power: See System Power
Lag Ballast: A magnetic ballast having a lagging lamp
current with respect to the supply voltage. Current limiting
is primarily inductive; holds lamp power reasonably
constant with respect to lamp voltage variations
Lamp Power Factor: Power consumed by the lamp
divided by the product of RMS lamp voltage and RMS
lamp current; it is less than unity on magnetic ballasts
operating at 50 or 60 hz
Lamp Voltage: The RMS voltage of a fully warmed-up
lamp
Lamp Power: The power consumed by a lamp after
warm-up, measured in watts
Lamp Regulation: The ratio of lamp power to lamp
voltage, often expressed in graphical format
Lead Ballast: A magnetic ballast having a leading lamp
current with respect to the supply voltage; current limiting
is accomplished by means of an inductor as well as a
capacitor connected in series with the lamp; this includes
CWA and CWI ballasts
Light Center Length (LCL): The distance from the center of
the visible arc discharge to the bottom contact of the base
Line Regulation: The ratio of lamp power to ballast input
voltage often expressed as a percentage
Lumens: A measurement of light; takes into account the
human eye sensitivity curve so that more weight is given
to the yellow-green part of the light spectrum (photopic)
Lumen Maintenance: The lumen output of a lamp at a
given operating time or a percentage of 100 hour lumens
at that time
Lumens Per Watt (LPW): See Efficacy
Maximum Overall Length (MOL): The maximum
allowable distance from the top of the glass bulb to the
end contact of the base
Continued on next page
70
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Glossary of Terms
TECHNICAL INFORMATION
Mean Lumens: Light output at 40% of rated lamp life
Natural White®: Line of pulse start lamps that have
5000K color temperature, 90+ CRI and 90% lumen
maintenance
Normal (Low) Power-Factor (NPF) Ballast: A ballast
designed so that the input power factor is less than 90%
when the ballast is operated at the rated supply voltage
using a reference lamp
Open Circuit Current (Line): The RMS current measured
at the input terminals of a ballast with lamp removed or
inoperative
Open Circuit Voltage, Ballast (OCV): The voltage across
the output terminals of a ballast when no load is
connected (RMS, unless otherwise stated)
Operating Current (Line): The RMS current measured at
the input terminals of a ballast which is operating a
reference lamp
Operating Voltage: See Lamp Voltage
Opti-Wave® Ballast: A lag (magnetic) ballast designed
with a low current crest factor for improved lamp
performance. Opti-Wave lag ballasts are also optimized
for low open circuit current
Peak Lead Ballast: A CWA ballast that produces a highly
peaked open circuit voltage wave shape and a peaked
current wave shape
Photopic Light: Applicable during normal daytime
lighting conditions; describes lumen values measured
using the high luminance eye sensitivity function centered
at 555 nm (yellow-green). See page 18
Position Oriented Mogul Base (POMB): Used with
horizontal operated probe start lamps; has an alignment
pin in the base for proper lamp orientation when installed
into an EP39 socket
Power Factor (Ballast): The ratio of the ballast input
power (watts) divided by the product of the RMS ballast
supply voltage and ballast supply current
Probe Start Lamp: A metal halide lamp which uses a
starter electrode (probe) to assist in starting without the
use of an ignitor pulse; also contains a bimetal switch
and resistor
Pulse Start CWA Ballast: A CWA ballast using an ignitor
to start the lamp
Pulse Start Lamp: Specially designed metal halide lamp
that requires a high voltage pulse for starting; has no
starter electrode (probe) and has high starting gas pressure
Quad-tap Ballast: A magnetic lag ballast with input
voltage taps for four standard voltages - 120, 208, 240
and 277 volts
Rated Supply Voltage: The input voltage for which a
ballast is designed to operate, and to which performance
characteristics are referred
Reactor Ballast: A lag ballast with a single input voltage tap
Regulated Lag Ballast: A lag ballast with a third coil for
improved lamp power regulation
Restrike: To re-ignite the arc of an HID lamp
RMS: root-mean-square
S/P Ratio: The ratio of scotopic lumens to photopic
lumens. See page 18
Short-Circuit Current (Ballast): The current at the output
terminals of a ballast when the output is shorted (RMS,
unless otherwise stated)
Shroud: A quartz cylinder surrounding the arc tube of a
open-rated (ANSI Type-O) metal halide lamp; designed
to reduce the damage to the outer bulb if an arc tube
rupture occurs; required to pass the ANSI Type-O
containment test
Spectral Power Distribution: The distribution of radiant
power (watts) of a lamp as a function of wavelength (nm)
Starter: See Ignitor
Starting Current (Line): The RMS current measured
through the input terminals of a ballast 5 to 15 seconds
after a lamp has started
Starting Pulse: A high-voltage, low-energy pulse
superimposed on the open circuit voltage of some HID
ballasts to aid in starting a lamp
Sustaining Voltage: The instantaneous voltage available
to the lamp from the ballast at the time the lamp current
passes through zero
System Power: The power measured at the input
terminals of a ballast while operating a reference lamp
Tipless Arc Tube: An arc tube made without an auxiliary
exhaust tube for dosing gases and other ingredients
Type-E Lamps (Enclosed Rated Lamps): Lamps that must
be used in enclosed luminaires which meet the
requirements of UL1598.
Type-S Lamps: Lamps that do not contain a shroud
around the arc tube yet are considered “suitable” for
open luminaire operation, only if operated in the vertical
±15° position; do not meet ANSI criteria for containment
and must be turned off at least once per week for a
minimum of 15 minutes if operated continuously; These
lamps must be replaced at or before reaching rated lamp
life; not recommended by the NEC.
Type-O Lamps (Open Rated Lamps): Lamps that can be
operated in either open or enclosed luminaires and do
not need weekly shut-off; meet the ANSI criteria for
containment-rated operation; special exclusionary
sockets are available for these lamps to ensure that the
wrong lamp type is not used. See page 66
Uni-Form®: HIDirect’s pulse start lamp and ballast systems
that contain a formed body arc tube; requires a high
voltage pulse for starting; has improved lumen
maintenance
Reference
Guide
Rated Life: The number of operating hours at which 50%
of most metal halide lamps, or 70% to 80% for some
Uni-Form® pulse start lamps, initially installed will still be
operating
Scotopic Light: Applicable during dark nighttime lighting
conditions; describes lumen values measured using the
low luminance eye sensitivity function centered at 507 nm
(blue-green). See page 18
Ventronic™ ballast: HIDirect’s high frequency electronic
pulse start ballasts
Warm-Up Time: The amount of time from ignition of the
lamp to 90% of full light output
Watts: A measure of energy (in joules) being used or
emitted each second
White-Lux®: HIDirect’s line of retrofit metal halide lamps
that operate on high pressure sodium ballasts
UL “Temp code”: An Underwriters Laboratories (UL)
alphabetic temperature code for ballasts which
designates a range of temperature rise of wire over
ambient temperature. The code is found on the label
directly following the number 1029X, where X is the
appropriate alphabetic character
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
71
Lamp Cross-Reference
TECHNICAL INFORMATION
Lamp
Description
Product ANSI
Number Code
Philips
Osram/
Sylvania
GE
Uni-Form Pulse Start Lamps
®
Reference
Guide
50 WATT
MP 50W/U/UVS/PS/3K 10226 M110/O
MP50/U/MED MXR50/U/MED/O
MP 50W/C/U/UVS/PS/3K 10381 M110/O
MP50/C/U/MED MXR50/C/U/MED/O
MP 50W/C/U/UVS/PS 30041 M110/O
MP 50W/U/UVS/PS
32100 M110/O
MH 50W/U/PS
52312 M110/E
MXR50/U/MED
MH 50W/C/U/PS
13093 M110/E
MXR50/C/U/MED
70 WATT
MP 70W/U/UVS/PS
40389 M98/O
MP70/U/MED
MP 70W/U/UVS/PS/3K 45424 M98/O
MXR70/U/MED/O
MP 70W/C/U/UVS/PS 67115 M98/O
MP70/C/U/MED
MP 70W/C/U/UVS/PS/3K 14611 M98/O
MXR70/C/U/MED/O
MP 70W/C/U/ED28/UVS/PS/3K 22466 M98/O
MH 70W/U/PS
78138 M98/E
MVR70/U/MED
MH 70W/U/ED28/PS 16017 M98/E
MH 70W/C/U/PS
12180 M98/E
MVR70/C/U/MED
100 WATT
MP 100W/U/UVS/PS
96267 M90/O
MP100/U/MED
MP 100W/U/UVS/PS/3K 96770 M90/O
MXR100/U/MED/O
MP 100W/C/U/UVS/PS 11278 M90/O
MP100/C/U/MED
MP 100W/C/U/UVS/PS/3K 11245 M90/O
MXR100/C/U/MED/O
MP 100W/C/U/ED28/UVS/PS/3K 22145 M90/O
MH 100W/U/PS
27266 M90/E
MVR100/U/MED
MH 100W/U/ED28/PS 67868 M90/E
MH 100W/C/U/PS
15823 M90/E
MVR100/C/U/MED
MH 100W/C/U/ED28/PS 79986 M90/E
125 WATT
MP 125W/BU/UVS/PS 13341 M150/O
MP 125W/V/ED28/UVS/PS 25813 M150/O
MP 125W/C/BU/UVS/PS 43319 M150/O
MH 125W/HBU/PS
76602 M150/E
MH 125W/HBU/ED28/PS 61914 M150/E
MH 125W/C/HBU/PS 35638 M150/E
150 WATT
MP 150W/U/UVS/PS/740 22455 M102/O
MP150/U/MED
MP 150W/U/ED28/UVS/PS/740 58963 M102/O
MP 150W/U/UVS/PS/732 22522 M102/O
MXR150/U/MED/O
MP 150W/C/U/UVS/PS/737 22888 M102/O
MP150/C/U/MED
MP 150W/C/U/ED28/UVS/PS/737 32147 M102/O
MP 150W/C/U/UVS/PS/732 80039 M102/O
MXR150/C/U/MED/O
MH 150W/U/PS/740 99584 M102/E
MVR150/U/MED
MH 150W/U/ED28/PS/740 13556 M102/E
MH 150W/C/U/PS/737 94986 M102/E
MVR150/C/U/MED
MH 150W/C/U/ED28/PS/737 21344 M102/E
175 WATT
MP 175W/BU/UVS/PS/740 69854 M137/M152/O
MS 175W/BU/PS/740 68475 M137/M152/E MS175/BU/PS MS175/PS/BU-ONLY MVR175/VBU/PA
MS 175W/BU/MED/PS/740 16497 M137/M152/E
MS175/PS/BU-ONLY/MED MVR175/VBU/MED/PA
MS 175W/C/BU/PS/737 68246 M137/M152/E MS175/C/BU/PS MS175/C/PS/BU-ONLY MVR175/C/VBU/PA
MS 175W/C/BU/MED/PS/737 34691 M137/M152/E
MS175/C/PS/BU-ONLY/MED MVR175/C/VBU/MED/PA
200 WATT
MP 200W/V/UVS/PS/740 22147 M136/O
MP 200W/C/V/UVS/PS/737 59174 M136/O
MP 200W/C/V/UVS/PS/732 44872 M136/O
MS 200W/V/PS/740
57739 M136/E
MS200/PS/BU-ONLY/BT28
MS 200W/BU/MED/PS/740 60811 M136/E
MS 200W/C/V/PS/737 70345 M136/E
MS200/C/PS/BU-ONLY/BT28
MS 200W/C/BU/MED/PS/737 60812 M136/E
MS 200W/H75/T15/PS/740 70764 M136/E
250 WATT
MP 250W/BU/UVS/PS/740 64658 M138/M153/O
MP250/PS/BU-ONLY
MP 250W/C/BU/UVS/PS/737 32658 M138/M153/O
MP250/C/PS/BU-ONLY
MP 250W/BU/UVS/PS/EM/950 19523 M138/M153/O CDM250/V/O/PS/4K ALTO MCP250/PS/BU-ONLY/940 PB CMH250/V/PA/O
MPSE 250W/BU/UVS/950 95047 M___/O
MS 250W/V/PS/740
49621 M138/M153/E MS250/BU/PS MS250/PS/BU-ONLY MVR250/VBU/PA
MS 250W/H75/PS/740 81054 M138/M153/E MS250/HOR/PS
M250/PS/U
MVR250/HOR/PA
MS 250W/C/V/PS/737 81365 M138/M153/E MS250/C/BU/PS MS250/C/PS/BU-ONLY MVR250/C/VBU/PA
MS 250W/H75/T15/PS/740 57625 M138/M153/E
-
Lamp
Description
Product ANSI
Number Code
Philips
Osram/
Sylvania
GE
320 WATT
MP 320W/BU/ED37/UVS/PS/740 21714 M132/M154/O MP320/BU/PS
MPR320/VBU/XHO/PA
MP 320W/V/EL/ED37/UVS/PS/740 25984 M___/O
MP 320W/BU/ED28/UVS/PS/740 10103 M132/M154/O
MP320/350/PS/BU-ONLY/BT28
MP 320W/C/BU/ED28/UVS/PS/737 10104 M132/M154/O
MP320/350/C/PS/BU-ONLY/BT28 MPR320/C/PA/ED28
MP 320W/C/BU/ED37/UVS/PS/737 32795 M132/M154/O MP320/C/BU/PS
MPR320/C/VBU/XHO/PA
MP 320W/C/BU/ED37/UVS/PS/732 66506 M132/M154/O
MP 320W/C/V/EL/ED37/UVS/PS/737 32409 M___/O
MP 320W/BU/ED37/UVS/PS/EM/950 98520 M154/O CDM320/O/PS/4K/ALTO MCP320/PS/BU-ONLY/840/BT37 PB CMH320/V/PA/O
MP 320W/BU/ED28/UVS/PS/EM/950 98530 M154/O
MPSE 320W/BU/ED37/UVS/950 28712 M___/O
MPSE 320W/C/BU/ED37/UVS/950 35698 M___/O
MS 320W/V/ED37/PS/740 52236 M132/M154/E
MS 320W/V/ED28/PS/740 59194 M132/M154/E MS320/U/PS MS320/PS/BU-HOR MVR320/VBU/XHO/PA
MS 320W/H75/ED28/PS/740 47549 M132/M154/E
MS320/PS/BU-HOR MVR320/HOR/ED28/PA
MS 320W/H75/T15/L/PS/740 79710 M132/M154/E
MS 320W/C/V/ED28/PS/737 77594 M132/M154/E MS320/C/U/PS MS320/C/PS/BU-HOR MVR320/C/VBU/XHO/PA
MS 320W/C/V/ED37/PS/737 67712 M132/M154/E
MS 320W/C/H75/ED28/PS/737 12758 M132/M154/E
MS 320W/H75/T15/S/PS/740 57626 M132/M154/E
350 WATT
MP 350W/V/UVS/PS/740 22149 M131/O MP350/BU/PS MP350/400/PS/BU-ONLY MPR350/VBU/PA
MP 350W/V/EL/UVS/PS/740 44983 M___/O
MP 350W/V/ED28/UVS/PS/740 47887 M131/O
- MP320/350/PS/BU-ONLY/BT28
MP 350W/C/V/UVS/PS/737 44097 M131/O MP350/C/BU/PS MP350/400/C/PS/BU-ONLY MPR350/C/VBU/PA
MP 350W/C/V/UVS/PS/732 27845 M131/O
MPR350/C/VBU3K/PA
MP 350W/C/V/ED28/UVS/PS/737 55401 M131/O
- MP320/350/C/PS/BU-ONLY/BT28
MP 350W/C/V/EL/UVS/PS/737 48952 M___/O
MP 350W/BU/ED28/UVS/PS/EM/950 33149 M131/O
MP 350W/BU/UVS/PS/EM/950 51628 M131/O CDM350/V/O/PS/4K/ALTO
CMH350/V/PA/O
MP 350W/C/BU/UVS/PS/EM/950 38197 M131/O CDM350/C/V/O/PS/4K/ALTO
CMH350/C/V/PA/O
MPSE 350W/BU/UVS/950 62584 M___/O
MPSE 350W/C/BU/UVS/950 71035 M___/O
MS 350W/V/PS/740
98389 M131/E MS350/BU/PS
MVR350/VBU/XHO/PA/E
MS 350W/V/ED28/PS/740 52980 M131/E
MS 350W/H75/ED28/PS/740 46959 M131/E
MS 350W/H75/T15/PS/740 93749 M131/E
MS 350W/C/V/PS/737 71329 M131/E MS350/C/BU/PS
MVR350/C/VBU/XHO/PA/E
MS 350W/C/H75/PS/737 64866 M131/E MS350/HOR/PS
400 WATT
MP 400W/V/UVS/PS/740 71642 M135/M155/O MP400/BU/PS MP350/400/PS/BU-ONLY MPR400/VBU/XHO/PA
MP 400W/V/EL/UVS/PS/740 56745 M___/O
MP 400W/V/ED28/UVS/PS/740 12445 M135/M155/O
MP 400W/C/V/UVS/PS/737 45541 M135/M155/O MP400/C/BU/PS MP350/400/C/PS/BU-ONLY MPR400/C/VBU/XHO/PA
MP 400W/C/V/ED28/UVS/PS/737 88648 M135/M155/O
MP 400W/C/V/EL/UVS/PS/737 78752 M___/O
MP 400W/BU/ED28/UVS/PS/EM/950 72315 M155/O CDM400/O/PS/4KED28/ALTO
MP 400W/BU/UVS/PS/EM/950 57129 M155/O
CMH400/V/PA/O
MP 400W/C/BU/UVS/PS/EM/950 89410 M155/O CDM400/C/V/O/PS/4K/ALTO
CMH400/C/V/PA/O
MPSE 400W/BU/UVS/950 71564 M___/O
MPSE 400/C/BU/UVS/950 95103 M___/O
MS 400W/V/ED28/PS/740 85260 M135/M155/E
MS400/PS/BU-ONLY/BT28 MVR400/VBU/ED28/PA
MS 400W/H75/PS/740 58788 M135/M155/E MS400/HOR/PS M400/PS/U MVR400/HOR/PA
MS 400W/H75/ED28/PS/740 40124 M135/M155/E
M400/PS/U/BT28 MVR400/HOR/ED28/PA
MS 400W/V/PS/740
73531 M135/M155/E MS400/BU/PS MS400/PS/BU-ONLY MVR400/VBU/XHO/PA
MS 400W/C/V/PS/737 42401 M135/M155/E MS400/C/BU/PS MS400/C/PS/BU-ONLY MVR400/C/VBU/XHO/PA
MS 400W/C/V/ED28/PS/737 46416 M135/M155/E
MVR400/C/VBU/ED28/PA
MS 400W/C/H75/ED28/PS/737 55459 M135/M155/E
450 WATT
MP 450W/BU/UVS/PS/740 65072 M144/O
MP 450W/C/BU/UVS/PS/737 59216 M144/O
MP 450W/BU/EL/UVS/PS/740 30285 M___/O
MP 450W/C/BU/EL/UVS/PS/737 24808 M___/O
MPSE 450W/BU/UVS/950 95011 M___/O
MPSE 450W/C/BU/UVS/950 95012 M___/O
MS 450W/V/PS/740
10079 M144/E
MS 450W/C/V/PS/737 10138 M144/E
575 WATT
MP 575W/BU/BT37/PS/740 60023 M178/O
775 WATT
MP 775W/BU/BT37/PS/950 24983 M181/O
875 WATT
MP 875W/BU/BT37/PS/740 58953 M166/O
MP 875W/C/BU/BT37/PS/737 41686 M166/O
MS 875W/BU/BT37/PS/740 22619 M166/E
MS 875W/BD/BT37/PS/740 35426 M166/E
MS 875W/HOR/BT37/PS/740 33759 M166/E
1000 WATT
MS 1000W/BU/BT37/PS/740 71722 M141/E MS1000/BU/BT37/PS M1000/PS/U/BT37 MVR1000/U/BT37/PA
MS 1000W/HOR/T25/PS/734 49111 M141/E
-
72
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Lamp Cross-Reference
TECHNICAL INFORMATION
Lamp
Description
Product ANSI
Number Code
Philips
Osram/
Sylvania
GE
Lamp
Description
Product ANSI
Number Code
Philips
Osram/
Sylvania
GE
Natural White Pulse Start Lamps
Probe Start Metal Halide Lamps
High CRI - Replacement Lamps for Ceramic Metal Halide
250 WATT
MP 250W/BU/UVS/PS/EM/950 19523 M138/M153/O CDM250/V/O/PS/4K ALTO MCP250/PS/BU-ONLY/940 PB CMH250/V/PA/O
MPSE 250W/BU/UVS/950 95047 M___/O
320 WATT
MP 320W/BU/ED37/UVS/PS/EM/950 98520 M154/O CDM320/O/PS/4K/ALTO MCP320/PS/BU-ONLY/840/BT37 PB CMH320/V/PA/O
MP 320W/BU/ED28/UVS/PS/EM/950 98530 M154/O
MPSE 320W/BU/ED37/UVS/950 28712 M___/O
MPSE 320W/C/BU/ED37/UVS/950 35698 M___/O
350 WATT
MP 350W/BU/ED28/UVS/PS/EM/950 33149 M131/O
MP 350W/BU/UVS/PS/EM/950 51628 M131/O CDM350/V/O/PS/4K/ALTO
CMH350/V/PA/O
MP 350W/C/BU/UVS/PS/EM/950 38197 M131/O CDM350/C/V/O/PS/4K/ALTO
CMH350/C/V/PA/O
MPSE 350W/BU/UVS/950 62584 M___/O
MPSE 350W/C/BU/UVS/950 71035 M___/O
400 WATT
MP 400W/BU/ED28/UVS/PS/EM/950 72315 M155/O CDM400/O/PS/4KED28/ALTO
MP 400W/BU/UVS/PS/EM/950 57129 M155/O
CMH400/V/PA/O
MP 400W/C/BU/UVS/PS/EM/950 89410 M155/O CDM400/C/V/O/PS/4K/ALTO
CMH400/C/V/PA/O
MPSE 400W/BU/UVS/950 71564 M___/O
MPSE 400/C/BU/UVS/950 95103 M___/O
450 WATT
MPSE 450W/BU/UVS/950 95011 M___/O
MPSE 450W/C/BU/UVS/950 95012 M___/O
775 WATT
MP 775W/BU/BT37/PS/950 24983 M181/O
-
175 WATT Probe Start Lamps
MPI 175W/BU
32519 M57/O MP175/BU MP175/BU-ONLY MVR175/VBU/O
MPI 175W/C/BU
32520 M57/O
MP175/C/BU-ONLY MVR175/C/VBU/O
MH 175W/U
88791 M57/E
MH175/U
M175/U
MVR175/U
MH 175W/U/MED
15556 M57/E MH175/U/M M175/U/MED MVR175/U/MED
MH 175W/C/U
96627 M57/E MH175/C/U
M175/C/U
MVR175/C/U
MH 175W/C/U/MED
63187 M57/E MH175/C/U/M M175/C/U/MED MVR175/C/U/MED
MS 175W/BU
55087 M57/E
MS 175W/BU/MED
70310 M57/E
MS 175W/C/BU/3K
20981 M57/E MH175/3K/BU M175/3K/BU-ONLY
MS 175W/C/BU/MED/3K 52522 M57/E
MH 175W/U/T15
40335 M57/E
MS 175W/HOR
57330 M57/E
MS175/HOR
MVR175/HOR
MH 175W/U/5K
79881 M57/E
MH 175W/U/T15/10K 70136 M57/E
250 WATT Probe Start Lamps
MPI 250W/BU
60722 M58/O MP250/BU MP250/BU-ONLY MPR250/VBU/O
MPI 250W/C/BU
60723 M58/O
MP250/C/BU-ONLY MPR250/C/VBU/O
MH 250W/U
63052 M58/E
MH250/U
M250/U
MVR250/U
MH 250W/C/U
61290 M58/E MH250/C/U
M250/C/U
MVR250/C/U
MS 250W/BU
36297 M58/E
MS 250W/C/BU/3K
18477 M58/E MH250/3K/BU M250/3K/BU-ONLY
MS 250W/HOR
94883 M58/E
MS250/HOR
MVR250/HOR
MH 250W/U/T15
33479 M58/E
M250/U/ET18
MS 250W/HOR/T15
88353 M58/E
MS 250W/HOR/T15/3K 54843 M58/E
MH 250W/U/5K
27252 M58/E
MH 250W/U/T15/10K 63897 M58/E
400 WATT Probe Start Lamps
MPI 400W/BU
95527 M59/O MP400/BU MP400/BU-ONLY MPR400/VBU/HO/O
MPI 400W/C/BU
26091 M59/O MP400/C/BU MP400/C/BU-ONLY MPR400/C/VBU/HO/O
MH 400W/U
18520 M59/E
MH400/U
M400/U
MVR400/U
MH 400W/U/ED28
57540 M59/E MH400/U/ED28 M400/U/BT28 MVR400/U/ED28
MH 400W/C/U
83545 M59/E MH400/C/U
M400/C/U
MVR400/C/U
MH 400W/C/U/ED28 20753 M59/E
M400/C/U/BT28 MVR400/C/U/ED28
MS 400W/BU/ED28
40013 M59/E MS400/BU/ED28 MS400/BU-ONLY/BT-28 MVR400/VBU/ED28/HO
MS 400W/HOR
40509 M59/E
MS400/HOR MVR400/HOR/MOG
MS 400W/HOR/ED28 21929 M59/E
MS400/HOR/BT28 MVR400/HOR/BT28
MS 400W/C/HOR
64648 M59/E
MS400/C/HOR MVR400/C/HOR/MOG
MS 400W/C/HOR/ED28 24573 M59/E
MS400/C/HOR/BT28
MH 400W/U/T15
55422 M59/E
MS 400W/HOR/T15
55100 M59/E
MS 400W/HOR/T15/3K 32225 M59/E
MH 400W/U/5K
36813 M59/E
MH 400W/U/ED28/10K 27540 M59/E
1000 WATT Probe Start Lamps
MH 1000W/U
72051 M47/E MH1000/U
M1000/U
MVR1000/U
MH 1000W/U/BT37
15332 M47/E MH1000/U/BT37 M1000/U/BT37 MVR1000/U/BT37
MH 1000W/C/U
88460 M47/E MH1000/C/U M1000/C/U MVR1000/C/U
MS 1000W/BU
89113 M47/E MS1000/BU MS1000/BU-ONLY MVR1000/VBU/HO
MS 1000W/BU/BT37
13090 M47/E
MS 1000W/BU/T25
78952 M47/E
MS 1000W/HOR/BT37/3K 53702 M47/E
MH 1000W/U/5K
35914 M47/E
MS 1000W/HOR/SPORT 60 47503 M47/E
1500 WATT Probe Start Lamps
MH 1500W/HBU
18360 M48/E MH1500/U M1500/BU-HOR MVR1500/HBU
MH 1500W/U/XL
12342 M48/E
MVR1500/U/SPORTS
MS 1500W/HOR/XP/SPORT 60 82070 M48/E
1650 WATT Probe Start Lamps
MS 1650W/HOR/XP/SPORT 60 16419 M112/E
MVR1650/HOR
®
Specialty Lamps
Reference
Guide
Energy Retrofit - Energy Master® Lamps
150 WATT Energy Master Lamps
MH 150W/U/EM
44810 M107/E MH150/U/M
MH 150W/U/ED28/EM 69559 M107/E
M150/SS/U/BT28 MVR150/U/WM
MH 150W/C/U/EM
39083 M107/E MH150/C/U/M
360 WATT Energy Master Lamps
MPI 360W/BU/EM
38029 M165/O MP360/BU/EW MSP360/SS/BU-ONLY MPR360/VBU/WM/HO/O
MPI 360W/C/BU/EM
67293 M165/O MP360/C/BU/EW MSP360/C/SS/BU-ONLY MPR360/C/VBU/WM/HO/O
HPS Retrofit Metal Halide - White-Lux® Lamps
250 WATT White-Lux Lamps
MPI 250W/BU/LU
24785 S50/O
MPI 250W/C/BU/LU
10206 S50/O
MVR250/C/VBU/R
MH 250W/U/LU
91051 S50/E
MVR250/VBU/R
400 WATT White-Lux Lamps
MPI 400W/BU/LU
10044 S51/O
MH 400W/U/LU/ED28 59441 S51/E
MVR400/U/ED28/R
MH 400W/U/LU
52134 S51/E
MVR400/VBU/R
MH 400W/C/U/LU
72190 S51/E
MVR400/C/VBU/R
750 WATT White-Lux Lamps
MH 750W/U/LU/BT37 33940 S111/E
1000 WATT White-Lux Lamps
MS 1000W/V/LU/BT37 35892 S52/E
G12 Lamps
70 WATT Pulse Start G12 Lamps
HIT 70W/G12/UVS/3K 12108 M85/M98/E
HIT 70W/G12/UVS/4K 52983 M85/M98/E
100 WATT Pulse Start G12 Lamps
HIT 100W/G12/UVS/4K 89887 M90/E
150 WATT Pulse Start G12 Lamps
HIT 150W/G12/UVS/3K 12106 M81/M102/E
ARC150/T/U/830/G12
HIT 150W/G12/UVS/4K 25779 M81/M102/E
HQI-SE150/NDX ARC150/T/U/840/G12
Double Ended
70 WATT Double Ended
MH-DE 70W/UVS/3K
16786 M85/M98/E
HQI-DE70/WDX ARC70/TD/UVC/730
MH-DE 70W/UVS/4K
60248 M85/M98/E MHN70/TD/840 HQI-DE70/NDX ARC70/TD/UVC/743
MH-DE 70W/UVS/FS/6K 79470 M85/M98/E
150 WATT Double Ended
MH-DE 150W/UVS/3K 11295 M81/M102/E
HQI-DE150/WDX ARC150/TD/730/R7S
MH-DE 150W/UVS/4K 74756 M81/M102/E
HQI-DE150/NDX ARC150/TD/742/R7S
MH-DE 150W/UVS/FS/6K 29963 M81/M102/E
250 WATT Double Ended
MH-DE 250W/UVS/3K/Fc2 84727 M80/E
MH-DE 250W/UVS/4K/Fc2 72748 M80/E
MH-DE 250W/UVS/4K/RSC 22468 M80/E
1000 WATT Double Ended
MBIL S 1000W
22417 M---/F
1500 WATT Double Ended
MBIL S 1500W
22151 M---/F
M1500T7/DE SPL1500/H/652
2000 WATT Double Ended
MBIL S 2000W
22132 M---/F
M2000T8/DE
-
73
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Ballast Cross-Reference
TECHNICAL INFORMATION
Reference
Guide
Input
Voltage
74
Circuit
Type
HIDirect
Catalog #
Advanced
Catalog #
Universal
Catalog #
Howard
Catalog #
Input
Voltage
Circuit
Type
HIDirect
Catalog #
Advanced
Catalog #
Universal
Catalog #
Howard
Catalog #
Pulse Start Metal Halide Ballasts
Pulse Start Metal Halide Ballasts continued
50 WATT Pulse Start Ballasts ANSI M110
120/208/240/277
HX
V90D5731
71A5181 M50MLTLC3M
120/277/347
HX
V90J5731
120/277
HX
V90H5731
71A5181 M50MLTLC3M
70 WATT Pulse Start Ballasts ANSI M98
120/208/240/277
HX
V90D5832
71A5292 M70MLTLC3M
120/208/240/277
HX
V90D5833
120/277/347
HX
V90J5832
71A52A2
M70TRILC3M
120/277
HX
V90H5832
71A5292 M70MLTLC3M
120/277
HX
V90H5833
100 WATT Pulse Start Ballasts ANSI M90
120/208/240/277
HX
V90D5932
71A5390 M100MLTLC3M
120/277/347
HX
V90J5932
71A53A0 M100TRILC3M
120/277
HX
V90H5932
71A5390 M100MLTLC3M
277
Reactor V90U5920
71A5337
125 WATT Pulse Start Ballasts ANSI M150
120/208/240/277 CWA
V90D8811
120/277/347
CWA
V90J8811
120/227
CWA
V90H8811
277
Reactor V90U8820
150 WATT Pulse Start Ballasts ANSI M102
120/208/240/277 CWA
V90D7110
71A5492 M150MLTLC3M
120/277/347
CWA
V90J7110
71A54A3 M150TRILC3M
480/ (120T)
CWA V90Y7110T 71A5442-T M15048TLC3M
120/208/240/277
HX
V90D7130
71A5492 M150MLTLC3M
120/277/347
HX
V90J7130
71A54A2 M150TRILC3M
120/277
HX
V90H7130
71A5482 M150MLTLC3M
277
Reactor V90U7120
71A5437
175 WATT Pulse Start Ballasts ANSI M152/M137
120/208/240/277 CWA
V90D7210
71A5593 P175MLTAC3M
120/208/240/277 CWA
V90D7211
71A5593 P175MLTAC4L
120/277/347
CWA
V90J7210
71A55A3 P175TRIAC3M
480/ (120T)
CWA V90Y7210T 71A5543-T P17548TAC3M
277
Reactor V90U7221
200 WATT Pulse Start Ballasts ANSI M136
120/208/240/277 CWA
V90D7310
71A5692 P200MLTAC3M M0200-71C-611
120/208/240/277 CWA
V90D7311
71A5692
120/208/240/277 CWA HX V90D7330
120/277/347
CWA
V90J7310
71A56A2 P200TRIAC3M
480/ (120T)
CWA V90Y7310T 71A5642-T P20048TAC3M M0200-11C-611
277
Reactor V90U7321
71A5637 P200277RCEM M0200-08C-611
250 WATT Pulse Start Ballasts ANSI M153/M138
120/208/240/277 CWA
V90D8410
71A5792 P250MLTAC4M M0250-71C-611
120/208/240/277 CWA
V90D8411
71A5792 P250MLTAC4L M0250-71C-611
120/277/347
CWA
V90J8410
71A57A2 P250TRIAC4M
480/ (120T)
CWA V90Y8410T 71A5742-T P25048TAC4M M0250-11C-611
480/ (120T)
CWA V90Y8411T 71A5742-T
M0250-11C-611
277
Reactor V90U8421
71A5737 P250277RCEM
320 WATT Pulse Start Ballasts ANSI M154/M132
120/208/240/277 CWA
V90D7411
71A5892 P320MLTAC4M M0320-71C-611
120/208/240/277 CWA
V90D7412
71A5892 P320MLTAC40 M0320-71C-611
120/208/240/277 CWA
V90D7413
71A5892 P320MLTAC40 M0320-71C-611
120/277/347
CWA
V90J7411
71A58A2 P320TRIAC4M
480/ (120T)
CWA V90Y7411T 71A5842-T P32048TAC4M M0320-11C-611
480/ (120T)
CWA V90Y7412T 71A5842-T P32048TAC4L M0320-11C-611
277
Reactor V90U7421
71A5837 P320277RCEM M0320-08C-711
350 WATT Pulse Start Ballasts ANSI M131
120/208/240/277 CWA
V90D7512
71A5993 P350MLTAC4M M0350-71C-611
120/208/240/277 CWA
V90D7513
71A5993 P350MLTAC4M M0350-71C-611
120/277/347
CWA
V90J7512
71A59A3 P350TRIAC3M
480/ (120T)
CWA V90Y7512T 71A5943-T P35048TAC4M
277
Reactor V90U7521
71A5937 P350277RECM M0350-08C-711
Note: Venture does not provide any guarantee or warrant on the accuracy of this cross reference
guide. User should refer to website, online literature or call sales for their specific requirements.
400 WATT Pulse Start Ballasts ANSI M155/M135
120/208/240/277 CWA
V90D7612
71A6092 P400MLTAC4M M0400-71C-611
120/277/347
CWA
V90J7612
71A60A2 P400TRIAC4M
480/ (120T)
CWA V90Y7612T 71A6042-T P40048TAC4M M0400-11C-611
277
Reactor V90U7621
71A6137 P400277RCEM M0400-08C-711
450 WATT Pulse Start Ballasts ANSI M144
120/208/240/277 CWA
V90D8512
71A6393 P450MLTAC4M
120/277/347
CWA
V90J8511
71A63A3 P450TRIAC4M
480/ (120T)
CWA V90Y8512T 71A6042-T P45048TAC4M
120/208/240/277 HX-HPF V90D8530
277
Reactor V90U8521
71A6337
575 WATT Pulse Start Ballasts ANSI M178
120/208/240/277
HX
V90D5530
120/277/347
HX
V90J5530
480/ (120T)
HX
V90Y5530T
277
Reactor V90U5520
750 WATT Pulse Start Ballasts ANSI M149
120/208/240/277 CWA
V90D7910
71A64E2 P750MLTAC5M M0750-71C-611
120/277/347
CWA
V90J7910
71A64F2 P750TRIAC5M
480/ (120T)
CWA V90Y7910T 71A64F2-T P75048TAC5M M0750-11C-611
775 WATT Pulse Start Ballasts ANSI M???
120/208/240/277 CWA
V90D9610
480/ (120T)
CWA V90Y9610T
875 WATT Pulse Start Ballasts ANSI M166
120/208/240/277 CWA
V90D8611
71A6498
M0875-71C-611
120/208/240/277 CWA
V90D8612
71A6498
M0875-71C-611
120/277/347
CWA
V90J8611
71A64F8
480/ (120T)
CWA V90Y8611T 71A64F8-T
M0875-11C-611
480/ (120T)
CWA V90Y8612T 71A64F8-T
M0875-11C-611
480
Reactor V90Y8620
1000 WATT Pulse Start Ballasts ANSI M141
120/208/240/277 CWA
V90D7810
71A6593 P1000MLTAC5M500K M1000-71C-611
120/208/240/277 CWA
V90D7811
71A6593 P1000MLTAC5M500K M1000-71C-611
120/277/347
CWA
V90J7810
71A65F3
480/ 120T
CWA V90Y7810T 71A65F3-T
M1000-11C-611
Probe Start Metal Halide Ballasts
175 WATT Probe start Metal Halide BallastsANSI M57/M107
120/208/240/277 CWA
V90D6111
71A5570 M175MLTAC3M M0175-71C-212
120/277/347
CWA
V90J6111
71A55A0 M175TRIAC3M M0175-59C-212
480/ (120T)
CWA V90Y6111T 71A5540-T M17548TAC3N M0175-29C-211
120
CWA
V90B6112
71A5500 M17512OAC3M M0175-02C-212
250 WATT (3x4) Probe start Metal Halide Ballasts ANSI M58
120/208/240/277 CWA
V90D6211
71A5771 M250MLTAC3M M0250-71C-212
120/277/347
CWA
V90J6211
71A57A0
M0250-59C-212
480
CWA
V90Y6211
71A5741 M25048TAC3M M0250-11C-212
250 WATT (4x4) Probe Start Metal Halide Ballasts ANSI M58
120/208/240/277 CWA
V90D6212 71A550or 71A5790 M250MLTAC4M M0250-71C-211
120/277/347
CWA
V90J6212
71A57A0 M250TRIAC4M M0250-59C-211
480/ (120T)
CWA V90Y6212T
71A5740 M25048TAC4M M0250-29C-211 or
M0250-11C-611
400 WATT Probe Start Metal Halide Ballasts ANSI M59
120/208/240/277 CWA
V90D6413
71A6071 M400MLTAC4M M0400-71C-211
120/277/347
CWA
V90J6413
71A60A1 M400TRIAC4M M0400-59C-211
480/ (120T)
CWA V90Y6413T 71A6041-T M40048TAC4M M0400-29C-211 or
M0400-11C-611
1000 WATT Probe Start Metal Halide Ballasts ANSI M47
120/208/240/277 CWA
V90D6514
71A6572 M1000MLTAC5M M1000-71C-211
120/277/347
CWA
V90J6514
71A65A2 M1000TRIAC5M
480/ (120T)
CWA V90Y6514T 71A6542-T M100048TAC5M M1000-11C-212
1500 WATT Probe Start Metal Halide Ballasts ANSI M48
120/208/240/277 CWA
V90D6612
71A6772 M1500MLTAC5M M1500-71C-212
480/ (120T)
CWA V90Y6612T
71A6742 M150048TAC5M M1500-11C-212
1650 WATT Probe Start Ballasts ANSI M112
120/208/240
CWA
V90C6910
71A6890
277/347/480
CWA V90AA6910
71A68F0
-
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Product Descriptions
PRODUCT FINDER KEY
Lamp Product Codes
Ballast Part Number Codes
Your lamp has an imprinted code that identifies the important features you
need to select a replacement. A complete explanation appears below.
The ballast product number gives you complete information about the
ballast. An explanation appears below.
Lamp Description Example: MP 150W/C/U/ED28/PS/740
Lamp Type: 150 watt Uni-Form® lamp, ANSI Type-O, universal burning, coated
Ballast Part Number Example: V90D1434K
MP
150W
C
U
ED28
PS
740
Metal halide
type
Lamp
wattage
Outer
jacket
finish
Operating
position
Bulb shape
and diameter,
if non-standard
Pulse start
lamp
Color
temperature
family
Lamp Description Codes
For complete product listings and the most current up-to-date
information, visit us on-line at VentureLighting.com
90
D
14
3
4
K
Ballast
Type
Voltage
Lamp Type,
ANSI Code
Circuit
Design
Version
Suffix
Ballast Part Number Codes
Ballast Type
90 Core and Coil
Voltage
B 120
C 120/208/240
D 120/208/240/277
E 120/240
H 120/277
J
120/277/347
P 208
U 277
V 347
Y 480
Z 600
AA 277/347/480
AS 347/600
Lamp Type and ANSI Code
10 35W HPS
S76
11 50W HPS
S68
12 70W HPS
S62
13 100W HPS
S54
14 150W HPS (55V)
S55
16 200W HPS
S66
17 250W HPS
S50
19 400W HPS
S51
23 1000W HPS
S52
55 575W PS MH
M178
57 50W PS MH
M110
58 70W PS MH
M98
59 100W PS MH
M90
60 150W PS MH (DE)
M81
61 175W MH/150W MH M57/M107
62 250W MH
M58
63 2X400W MH
M59
64 400W MH/360W MH M59/M165
65 1000W MH
M47
66 1500W MH
M48
67 2000W PS MH (DE)
M134
69 1650W MH
M112
71 150W PS MH
M102
72 175W PS MH
M152
73 200W PS MH
M136
74 320W PS MH
M132/M154
75 350W PS MH
M131
76 400W PS MH
M155
78 1000W PS MH
M141
79 750W PS MH
M149
81 70W PS MH (DE)
M85
82 100W PS MH (DE)
M91
83 250W PS MH (DE)
M80
84 250W PS MH
M153
85 450W PS MH
M144
86 875W PS MH
M166
87 300W PS MH
M151
88 125W PS MH
M150
91 2X1000W MH
M47
96 775W PS MH
M181
Circuit Type
1 CWA
2 Reactor
3 HX (Lag HPF)
4 HX (Lag NPF)
5 CWI
Suffix
B with welded bracket
C with capacitor
K pre-wired with capacitor, ignitor if required, &
adapter mounting kit
T with 120V tap
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Product
Index
Position of Operation
U
Universal operating position
BU Lamps designed for base up (±15°) operating position
V
Lamps designed for a vertical (±15°) operating position
H75 Lamps designed for horizontal operation (±75° from
horizontal) without the need of a position oriented base
socket
HBD Lamps designed for horizontal to base down operating
position (typically base down ±90°, except 1500W which
is base down ±105°)
HBU Lamps designed for horizontal to base up operating
position (or base up ±90°, except 1500W which is base up
±105°)
HOR Horizontal high-performance standard probe start lamps
designed for horizontal ±45° operation; uses POM base
Bulb Shape, Size and Finish
C
Lamps with a coated (diffuse) outer jacket
MH-DE Double ended lamp
ED## Bulb shape and diameter in 1/8 in. (i.e. diameter of ED28
is 3.5 in.)
EL
A Uni-Form lamp designed for operation on electronic
ballasts in dimming applications
LU
White-Lux® lamp - MH lamp for use with HPS ballast
MBIL High wattage, double ended lamp
MED Medium base
MH Metal halide, typically universal “U”, “HBU” or “HBD”
operating positions
MP Uni-Form lamps with a protected (shrouded) arc tube
designed for open luminaires
MPI Lamps with a protected (shrouded) arc tube designed to
replace standard (probe start) lamps in open luminaires
MPSE Lamps designed for operation on electronic ballast with a
protected (shrouded) arc tube
MS High output MH lamps for dedicated operating positions
PS
Pulse start lamp
UVS UV Shield® lamps with reduced ultraviolet output
Color Temperature and CRI
3K 3000K - 3200K correlated color temperature
4K 3700K - 4000K correlated color temperature
5K 5000K correlated color temperature
6K 6500K correlated color temperature
10K 10,000K correlated color temperature
732 3200K color, 70 CRI lamps
734 3400K color, 68 CRI lamps
737 3700K color, 70 CRI lamps
740 4000K color, 68 CRI lamps
950 Natural White® lamp, 5000K color, high CRI (90+) lamps
V
Venture
Lighting
75
Product Index - Lamps
Product
Index
PRODUCT FINDER KEY
Part
Product
Watts Number Description
Catalog
Section
35
35
35
35
35
50
50
50
50
50
50
70
70
70
70
70
70
70
70
70
70
70
70
70
70
70
100
100
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
125
125
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
Retrofit Systems
Retrofit Systems
Retrofit Systems
Retrofit Systems
Retrofit Systems
Uni-Form®
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Specialty
Uni-Form
Uni-Form
Uni-Form
Specialty
Uni-Form
Uni-Form
Uni-Form
Specialty
Specialty
Uni-Form
Uni-Form
Specialty
HPS
HPS
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Specialty
Uni-Form
Uni-Form
HPS
HPS
HPS
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Specialty
Specialty
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Specialty
Specialty
Uni-Form
Specialty
Specialty
Uni-Form
Specialty
Specialty
Uni-Form
Uni-Form
Uni-Form
HPS
HPS
60622
60633
60621
60631
60632
10226
10381
13093
30041
32100
52312
12108
12180
14611
16017
16786
22466
40389
45424
52983
60248
67115
78138
79470
84762
51918
11245
11278
15823
22145
27266
67868
79986
89887
96267
96770
25472
69456
69457
13341
25813
35638
43319
61914
76602
11295
12106
13556
21344
22455
22522
22888
25779
29963
32147
39083
44810
58963
69559
74756
80039
94986
99584
64616
28639
VETF-J35W1-MR16SP950-WT
VETF-J35W2-MR16SP950-WT
MPSE 35W/GX10/MR16/950/SP/WH
MPSE 35W/GX10/MR16/950/NFL/WH
MPSE 35W/GX10/MR16/950/WFL/WH
MP 50W/U/UVS/PS/3K
MP 50W/C/U/UVS/PS/3K
MH 50W/C/U/PS
MP 50W/C/U/UVS/PS
MP 50W/U/UVS/PS
MH 50W/U/PS
HIT 70W/G12/UVS/3K
MH 70W/C/U/PS
MP 70W/C/U/UVS/PS/3K
MH 70W/U/ED28/PS
MH-DE 70W/UVS/3K
MP 70W/C/U/ED28/UVS/PS/3K
MP 70W/U/UVS/PS
MP 70W/U/UVS/PS/3K
HIT 70W/G12/UVS/4K
MH-DE 70W/UVS/4K
MP 70W/C/U/UVS/PS
MH 70W/U/PS
MH-DE 70W/UVS/FS/6K
HPS070/U CLEAR
LU 70/MED
MP 100W/C/U/UVS/PS/3K
MP 100W/C/U/UVS/PS
MH 100W/C/U/PS
MP 100W/C/U/ED28/UVS/PS/3K
MH 100W/U/PS
MH 100W/U/ED28/PS
MH 100W/C/U/ED28/PS
HIT 100W/G12/UVS/4K
MP 100W/U/UVS/PS
MP 100W/U/UVS/PS/3K
LU 100
LU 100/MED
HPS100/U/MED CLEAR
MP 125W/BU/UVS/PS
MP 125W/V/ED28/UVS/PS
MH 125W/C/HBU/PS
MP 125W/C/BU/UVS/PS
MH 125W/HBU/ED28/PS
MH 125W/HBU/PS
MH-DE 150W/UVS/3K
HIT 150W/G12/UVS/3K
MH 150W/U/ED28/PS/740
MH 150W/C/U/ED28/PS/737
MP 150W/U/UVS/PS/740
MP 150W/U/UVS/PS/732
MP 150W/C/U/UVS/PS/737
HIT 150W/G12/UVS/4K
MH-DE 150W/UVS/FS/6K
MP 150W/C/U/ED28/UVS/PS/737
MH 150W/C/U/EM
MH 150W/U/EM
MP 150W/U/ED28/UVS/PS/740
MH 150W/U/ED28/EM
MH-DE 150W/UVS/4K
MP 150W/C/U/UVS/PS/732
MH 150W/C/U/PS/737
MH 150W/U/PS/740
LU 150/55
HPS150/U/MED CLEAR
Page
#
44
44
44
44
44
22
22
22
22
22
22
51
23
23
23
51
23
23
23
51
51
23
23
51
59
59
24
24
24
24
24
24
24
51
24
24
59
59
59
25
25
25
25
25
25
51
51
26
26
26
26
26
51
51
26
46
46
26
46
51
26
26
26
59
59
Part
Product
Watts Number Description
Catalog
Section
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
200
200
200
200
200
200
200
200
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
290
Probe Start
54
Uni-Form
27
Probe Start
54
Probe Start
54
Probe Start
54
Uni-Form
27
Specialty,Probe Start 50,54
Probe Start
54
Probe Start
54
Probe Start
54
Probe Start
54
Uni-Form
27
Uni-Form
27
Uni-Form
27
Specialty,Probe Start 50,54
Probe Start
54
Probe Start
54
Probe Start
54
Probe Start
54
Uni-Form
28
Uni-Form
28
Uni-Form
28
Uni-Form
28
Uni-Form
28
Uni-Form
28
Uni-Form
28
H75,Uni-Form,Specialty 20,28,50
Specialty
48
Probe Start
54
Natural White®
16
Specialty
51
Specialty
48
Probe Start
54
Specialty,Probe Start 50,54
Probe Start
54
Specialty,Probe Start 50,54
H75,Uni-Form,Specialty 20,29,50
Probe Start
54
Probe Start
54
Probe Start
54
Probe Start
54
Specialty,Probe Start 50,54
Specialty
51
Specialty
51
Specialty,Probe Start 50,54
Specialty
48
Probe Start
54
Natural White
16
Uni-Form
29
Uni-Form
29
Uni-Form
29
H75,Uni-Form 20,29
Uni-Form
29
HPS
59
Natural White
16
15556
16497
20981
32519
32520
34691
40335
52522
55087
57330
63187
68246
68475
69854
70136
70310
79881
88791
96627
22147
44872
57739
59174
60811
60812
70345
70764
10206
18477
19523
22468
24785
27252
33479
36297
54843
57625
60722
60723
61290
63052
63897
72748
84727
88353
91051
94883
95047
32658
49621
64658
81054
81365
35946
95005
MH 175W/U/MED
MS 175W/BU/MED/PS/740
MS 175W/C/BU/3K
MPI 175W/BU
MPI 175W/C/BU
MS 175W/C/BU/MED/PS/737
MH 175W/U/T15
MS 175W/C/BU/MED/3K
MS 175W/BU
MS 175W/HOR
MH 175W/C/U/MED
MS 175W/C/BU/PS/737
MS 175W/BU/PS/740
MP 175W/BU/UVS/PS/740
MH 175W/U/T15/10K
MS 175W/BU/MED
MH 175W/U/5K
MH 175W/U
MH 175W/C/U
MP 200W/V/UVS/PS/740
MP 200W/C/V/UVS/PS/732
MS 200W/V/PS/740
MP 200W/C/V/UVS/PS/737
MS 200W/BU/MED/PS/740
MS 200W/C/BU/MED/PS/737
MS 200W/C/V/PS/737
MS 200W/H75/T15/PS/740
MPI 250W/C/BU/LU
MS 250W/C/BU/3K
MP 250W/BU/UVS/PS/EM/950
MH-DE 250W/UVS/4K/RSC
MPI 250W/BU/LU
MH 250W/U/5K
MH 250W/U/T15
MS 250W/BU
MS 250W/HOR/T15/3K
MS 250W/H75/T15/PS/740
MPI 250W/BU
MP1 250W/C/BU
MH 250W/C/U
MH 250W/U
MH 250W/U/T15/10K
MH-DE 250W/UVS/4K/Fc2
MH-DE 250W/UVS/3K/Fc2
MS 250W/HOR/T15
MH 250W/U/LU
MS 250W/HOR
MPSE 250W/BU/UVS/950
MP 250W/C/BU/UVS/PS/737
MS 250W/V/PS/740
MP 250W/BU/UVS/PS/740
MS 250W/H75/PS/740
MS 250W/C/V/PS/737
LU 250
MPSE 290W/BU/UVS/950
76
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Page
#
Product Index - Lamps
PRODUCT FINDER KEY
Part
Product
Watts Number Description
Catalog
Section
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
350
360
360
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
Natural White
16
Natural White
16
Uni-Form
30
Uni-Form
30
H75,Uni-Form 20,30
Uni-Form
30
Uni-Form
30
Natural White
16
Uni-Form
30
Uni-Form
30
Natural White
16
H75,Uni-Form 20,30
Uni-Form
30
H75,Uni-Form,Specialty20,30,50
Uni-Form
30
Uni-Form
30
Uni-Form
30
Uni-Form
30
H75,Uni-Form,Specialty 20,30,50
Natural White
16
Uni-Form
32
Uni-Form
32
Natural White
16
Uni-Form
32
Uni-Form
32
H75,Uni-Form 20,32
Uni-Form
32
Uni-Form
32
Natural White
16
Uni-Form
32
Uni-Form
32
Natural White
16
H75,Uni-Form 20,32
Natural White
16
Uni-Form
32
H75,Uni-Form,Specialty 20,32,50
Uni-Form
32
Specialty
46
Specialty
46
Natural White
16
Natural White
16
Natural White
16
Specialty
48
Uni-Form
34
Probe Start
55
Probe Start
55
Probe Start
55
Probe Start
55
Probe Start
55
Probe Start
55
Specialty,Probe Start 50,55
Probe Start
55
Probe Start
55
H75,Uni-Form 20,34
Probe Start
55
Uni-Form
34
Uni-Form
34
Uni-Form
34
98520
98530
10103
10104
12758
21714
25984
28712
32409
32795
35698
47549
52236
57626
59194
66506
67712
77594
79710
38197
22149
27845
33149
44097
44983
46959
47887
48952
51628
52980
55401
62584
64866
71035
71329
93749
98389
38029
67293
57129
72315
89410
10044
12445
18520
20753
21929
24573
26091
27540
32225
36813
40013
40124
40509
42401
45541
46416
MP 320W/BU/ED37/UVS/PS/EM/950
MP 320W/BU/ED28/UVS/PS/EM/950
MP 320W/BU/ED28/UVS/PS/740
MP 320W/C/BU/ED28/UVS/PS/737
MS 320W/C/H75/ED28/PS/737
MP 320W/BU/ED37/UVS/PS/740
MP 320W/V/ED37/EL/UVS/PS/740
MPSE 320W/BU/ED37/UVS/950
MP 320W/C/V/ED37/EL/UVS/PS/737
MP 320W/C/BU/ED37/UVS/PS/737
MPSE 320W/C/BU/ED37/UVS/950
MS 320W/H75/ED28/PS/740
MS 320W/V/ED37/PS/740
MS 320W/H75/T15/S/PS/740
MS 320W/V/ED28/PS/740
MP 320W/C/BU/ED37/UVS/PS/732
MS 320W/C/V/ED37/PS/737
MS 320W/C/V/ED28/PS/737
MS 320W/H75/T15/L/PS/740
MP 350W/C/BU/UVS/PS/EM/950
MP 350W/V/UVS/PS/740
MP 350W/C/V/UVS/PS/732
MP 350W/BU/ED28/UVS/PS/EM/950
MP 350W/C/V/UVS/PS/737
MP 350W/V/EL/UVS/PS/740
MS 350W/H75/ED28/PS/740
MP 350W/V/ED28/UVS/PS/740
MP 350W/C/V/EL/UVS/PS/737
MP 350W/BU/UVS/PS/EM/950
MS 350W/V/ED28/PS/740
MP 350W/C/V/ED28/UVS/PS/737
MPSE 350W/BU/UVS/950
MS 350W/C/H75/PS/737
MPSE 350W/C/BU/UVS/950
MS 350W/C/V/PS/737
MS 350W/H75/T15/PS/740
MS 350W/V/PS/740
MPI 360W/BU/EM
MPI 360W/C/BU/EM
MP 400W/BU/UVS/PS/EM/950
MP 400W/BU/ED28/UVS/PS/EM/950
MP 400W/C/BU/UVS/PS/EM/950
MPI 400W/BU/LU
MP 400W/V/ED28/UVS/PS/740
MH 400W/U
MH 400W/C/U/ED28
MS 400W/HOR/ED28
MS 400W/C/HOR/ED28
MPI 400W/C/BU
MH 400W/U/ED28/10K
MS 400W/HOR/T15/3K
MH 400W/U/5K
MS 400W/BU/ED28
MS 400W/H75/ED28/PS/740
MS 400W/HOR
MS 400W/C/V/PS/737
MP 400W/C/V/UVS/PS/737
MS 400W/C/V/ED28/PS/737
Page
#
Part
Product
Watts Number Description
Catalog
Section
Page
#
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
450
450
450
450
450
450
450
450
575
750
775
875
875
875
875
875
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1500
1500
1500
1500
1650
2000
Specialty
Specialty,Probe Start
Specialty,Probe Start
H75,Uni-Form
Uni-Form
Probe Start
H75,Uni-Form
Specialty
Probe Start
Natural White
Uni-Form
Specialty
Uni-Form
Uni-Form
Probe Start
Uni-Form
Uni-Form
Natural White
Probe Start
HPS
Natural White
Natural White
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Specialty
Natural White
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Uni-Form
Probe Start
Probe Start
Specialty
Probe Start
Specialty,Probe Start
Uni-Form,Specialty
Specialty,Probe Start
Uni-Form
Probe Start
Probe Start
Probe Start
Probe Start
Specialty
HPS
Specialty,Probe Start
Specialty,Probe Start
Specialty,Probe Start
Specialty
Specialty,Probe Start
Specialty
48
50,55
50,55
20,34
34
55
20,34
48
55
16
34
48
34
34
55
34
34
16
55
59
16
16
35
35
35
35
35
35
36
48
16
37
37
37
37
37
55
55
48
55
49,55
38,50
49,55
38
55
55
55
55
52
59
49,55
49,55
49,55
52
49,55
52
52134
55100
55422
55459
56745
57540
58788
59441
64648
71564
71642
72190
73531
78752
83545
85260
88648
95103
95527
17934
95011
95012
10079
10138
59216
65072
24908
30285
60023
33940
24983
22619
33759
35426
41686
58953
13090
15332
35892
35914
47503
49111
53702
71722
72051
78952
88460
89113
22417
86346
12342
18360
82070
22151
16419
22132
MH 400W/U/LU
MS 400W/HOR/T15
MH 400W/U/T15
MS 400W/C/H75/ED28/PS/737
MP 400W/V/EL/UVS/PS/740
MH 400W/U/ED28
MS 400W/H75/PS/740
MH 400W/U/LU/ED28
MS 400W/C/HOR
MPSE 400W/BU/UVS/950
MP 400W/V/UVS/PS/740
MH 400W/C/U/LU
MS 400W/V/PS/740
MP 400W/C/V/EL/UVS/PS/737
MH 400W/C/U
MS 400W/V/ED28/PS/740
MP 400W/C/V/ED28/UVS/PS/737
MPSE 400W/C/BU/UVS/950
MPI 400W/BU
LU 400
MPSE 450W/BU/UVS/950
MPSE 450W/C/BU/UVS/950
MS 450W/V/PS/740
MS 450W/C/V/PS/737
MP 450W/C/BU/UVS/PS/737
MP 450W/BU/UVS/PS/740
MP 450W/C/BU/EL/UVS/PS/737
MP 450W/BU/EL/UVS/PS/740
MP 575W/BU/BT37/PS/740
MH 750W/U/LU/BT37
MP 775W/BU/BT37/PS/950
MS 875W/BU/BT37/PS/740
MS 875W/HOR/BT37/PS/740
MS 875W/BD/BT37/PS/740
MP 875W/C/BU/BT37/PS/737
MP 875W/BU/BT37/PS/740
MS 1000W/BU/BT37
MH 1000W/U/BT37
MS 1000W/V/LU/BT37
MH 1000W/U/5K
MS 1000W/HOR/SPORT 60
MS 1000W/HOR/T25/PS/734
MS 1000W/HOR/BT37/3K
MS 1000W/BU/BT37/PS/740
MH 1000W/U
MS 1000W/BU/T25
MH 1000W/C/U
MS 1000W/BU
MBIL S 1000W
HPS1000/U CLEAR
MH 1500W/U/XL
MH 1500W/HBU
MS 1500W/HOR/XP/SPORT 60
MBIL S 1500W
MS 1650W/HOR/XP/SPORT 60
MBIL S 2000W
Product
Index
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Product
Index
77
Product Index - Ballasts
Product
Index
PRODUCT FINDER KEY
78
Part
Watts Number
Product
Description
Catalog Page
Section
#
Part
Watts Number
Product
Description
Catalog Page
Section
#
35
35
35
35
50
50
50
50
50
50
50
50
50
70
70
70
70
70
70
70
70
70
70
70
70
100
100
100
100
100
100
100
100
100
100
100
125
125
125
125
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
175
175
175
175
175
175
175
175
175
175
175
175
175
175
175
HPS 120V RCTR
HPS 120V RCTR
HPS DUAL HX
HPS 347V HX
HPS 120V RCTR
HPS 120V RCTR
PS MH QUAD HX
HPS DUAL HX
HPS DUAL CWI
HPS DUAL HX
PS MH DUAL HX
PS MH TRI HX
HPS 347V HX
HPS 120V RCTR
HPS 120V RCTR
HPS QUAD HX
PS MH QUAD HX
PS MH QUAD HX
HPS DUAL CWI
HPS DUAL CWI
PS MH DUAL HX
PS MH DUAL HX
HPS TRI HX
PS MH TRI HX
HPS 600V CWI
HPS 120V RCTR
HPS 120V RCTR
HPS TRI CWI
HPS QUAD HX
PS MH QUAD HX
HPS DUAL CWI
PS MH DUAL HX
HPS TRI HX
PS MH TRI HX
PS MH 277V RCTR
HPS 600V CWI
PS MH QUAD CWA
PS MH DUAL CWA
PS MH TRI CWA
PS MH 277V RCTR
HPS 120V RCTR
HPS 120V RCTR
HPS TRI CWI
HPS QUAD HX
PS MH QUAD CWA
PS MH QUAD HX
PS MH DUAL HX
HPS TRI HX
PS MH TRI CWA
PS MH TRI HX
PS MH 277V RCTR
PS MH 277V RCTR
HPS 347V CWI
HPS 480V CWI
PS MH 480V CWA
HPS 600V CWI
MH 120V CWA
MH QUAD CWA
MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD CWA
MH DUAL CWI
MH TRI CWA
MH TRI CWA
PS MH TRI CWA
MH 208V CWI
PS MH 277V Opti-Wave®
MH 480V CWA
PS MH 480V CWA
PS MH 480V CWA
MH 600V CWI
HPS
HPS
HPS
HPS
HPS
HPS
Uni-Form®
HPS
HPS
HPS
Uni-Form
Uni-Form
HPS
HPS
HPS
HPS
Uni-Form
Uni-Form
HPS
HPS
Uni-Form
Uni-Form
HPS
Uni-Form
HPS
HPS
HPS
HPS
HPS
Uni-Form
HPS
Uni-Form
HPS
Uni-Form
Uni-Form
HPS
Uni-Form
Uni-Form
Uni-Form
Uni-Form
HPS
HPS
HPS
HPS
Uni-Form
Uni-Form
Uni-Form
HPS
Uni-Form
Uni-Form
Uni-Form
Uni-Form
HPS
HPS
Uni-Form
HPS
Probe Start
Probe Start
Probe Start
Uni-Form
Uni-Form
Probe Start
Probe Start
Probe Start
Uni-Form
Probe Start
Uni-Form
Probe Start
Uni-Form
Uni-Form
Probe Start
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
320
350
350
350
350
350
350
350
350
350
350
350
PS MH 277V Opti-Wave Housing
PS MH 277V Opti-Wave Housing
PS MH QUAD HX Housing
PS MH 480V HX Housing
PS MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD HX
HPS DUAL CWI
PS MH TRI CWA
PS MH TRI HX
PS MH 277V Opti-Wave
HPS 347V CWI
PS MH 480V CWA
PS MH 480V CWA
PS MH 480V CWA
PS MH 480V HX
PS MH 277V Opti-Wave Housing
PS MH QUAD CWA Housing
HPS DUAL CWI
HPS QUAD CWA
MH QUAD CWA
MH QUAD CWA
MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD CWA
HPS DUAL CWI
MH DUAL CWI
HPS TRI CWA
MH TRI CWA
MH TRI CWA
PS MH TRI CWA
MH 208V CWI
PS MH 277V Opti-Wave
HPS 480V CWA
MH 480V CWA
MH 480V CWA
PS MH 480V CWA
PS MH DUAL CWA
MH 600V CWI
Ventronic 208-277V
PS MH 277V Opti-Wave Housing
PS MH QUAD HX Housing
PS MH QUAD CWA Housing
PS MH TRI CWA Housing
PS MH 480V CWA Housing
PS MH 480V HX Housing
PS MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD HX
PS MH TRI CWA
PS MH TRI HX
PS MH 277V Opti-Wave
PS MH 480V CWA
PS MH 480V CWA
PS MH 480V HX
Ventronic 208-277V
PS MH 277V Opti-Wave Housing
PS MH QUAD HX Housing
PS MH 480V HX Housing
PS MH QUAD CWA
PS MH QUAD HX
PS MH TRI CWA
PS MH TRI HX
PS MH 277V Opti-Wave
PS MH 480V CWA
PS MH 480V HX
Systems
43
Systems
43
Systems
43
Systems
43
Uni-Form
28
Uni-Form
28
Uni-Form
28
Uni-Form
28
HPS
61
Uni-Form
28
Uni-Form
28
Uni-Form
28
HPS
61
Uni-Form
28
Uni-Form
28
Uni-Form
28
Uni-Form
28
Systems
43
Systems
43
HPS
61
HPS
61
Probe Start
56
Probe Start
56
Probe Start
56
NW,Uni-Form 17,29
Uni-Form
29
HPS
61
Probe Start
56
HPS
61
Probe Start
56
Probe Start
56
NW,Uni-Form 17,29
Probe Start
56
NW,Uni-Form 17,29
HPS
61
Probe Start
56
Probe Start
56
NW,Uni-Form 17,29
Uni-Form
29
Probe Start
56
NW,Uni-Form,System 17,30,42
Systems
43
Systems
43
Systems
43
Systems
43
Systems
43
Systems
43
NW,Uni-Form 17,31
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form 17,30
NW,Uni-Form,System 17,32,42
Systems
43
Systems
43
Systems
43
NW,Uni-Form 17,32
NW,Uni-Form 17,32
NW,Uni-Form 17,32
NW,Uni-Form 17,32
NW,Uni-Form 17,32
NW,Uni-Form 17,32
NW,Uni-Form 17,32
V90B1020
V90B1020C
V90E1030
V90V1030
V90B1120
V90B1120C
V90D5731
V90E1131
V90E1151
V90H1132
V90H5731
V90J5731
V90V1131
V90B1222
V90B1222C
V90D1233
V90D5832
V90D5833
V90E1250
V90E1252
V90H5832
V90H5833
V90J1232
V90J5832
V90Z1252
V90B1322
V90B1322C
V90C1353
V90D1333
V90D5932
V90E1350
V90H5932
V90J1332
V90J5932
V90U5920
V90Z1352
V90D8811
V90H8811
V90J8811
V90U8820
V90B1422
V90B1422C
V90C1454
V90D1435
V90D7110
V90D7130
V90H7130
V90J1434
V90J7110
V90J7130
V90U7120
V90U7121
V90V1454T
V90Y1454
V90Y7110T
V90Z1454T
V90B6112
V90D6111
V90D6112
V90D7210
V90D7211
V90E6150
V90J6111
V90J6112
V90J7210
V90P6150T
V90U7221
V90Y6111T
V90Y7210T
V90Y7211T
V90Z6150
60
60
60
60
60
60
22
60
60
60
22
22
60
60
60
60
23
23
60
60
23
23
60
23
60
60
60
60
60
24
60
24
60
24
24
60
25
25
25
25
60
60
60
60
26
26
26
60
26
26
26
26
60
60
26
60
56
56
56
27
27
56
56
56
27
56
27
56
27
27
56
OPM-1-200U
OPM-2-200U
OPM-3-200D(x)
OPM-3-200Y
V90D7310
V90D7311
V90D7312
V90D7330
V90E1650
V90J7310
V90J7330
V90U7321
V90V1650
V90Y7311T
V90Y7312T
V90Y7310T
V90Y7330T
OPM-2-250U
OPM-1-250D(x)
V90AS1750
V90D1711
V90D6211
V90D6212
V90D6215
V90D8410
V90D8411
V90E1750
V90E6250
V90J1711
V90J6211
V90J6212
V90J8410
V90P6250T
V90U8421
V90Y1711T
V90Y6211
V90Y6212T
V90Y8410T
V90Y8411T
V90Z6250
OPE320HF
OPM-2-320U
OPM-3-320D(x)
OPM-1-320D(x)
OPM-1-320J(x)
OPM-1-320Y
OPM-3-320Y
V90D7411
V90D7412
V90D7413
V90D7430
V90J7411
V90J7430
V90U7421
V90Y7411T
V90Y7412T
V90Y7430T
OPE350HF
OPM-2-350U
OPM-3-350D(x)
OPM-3-350Y
V90D7512
V90D7530
V90J7512
V90J7530
V90U7521
V90Y7512T
V90Y7530T
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Product Index - Ballasts
PRODUCT FINDER KEY
Part
Watts Number
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
430
450
450
450
450
450
450
450
450
450
450
450
575
575
575
575
575
575
575
600
775
775
875
875
875
875
875
875
875
875
875
Product
Description
OPE400HF
Ventronic 208-277V
OPHM-2-400U PS MH 277V Opti-Wave Housing
OPHM-1-400D(x) PS MH QUAD CWA Housing
OPHM-1-400Y PS MH 480V CWA Housing
V90AS1950
HPS DUAL CWI
V90D1912
HPS QUAD CWA
V90D6412
MH QUAD CWA
V90D6413
MH QUAD CWA
V90D6414
MH QUAD CWA
V90D7612
PS MH QUAD CWA
V90E1950
HPS DUAL CWI
V90E6450
MH DUAL CWI
V90J1911
HPS TRI CWA
V90J6413
MH TRI CWA
V90J7612
PS MH TRI CWA
V90P1950T
HPS 208V CWI
V90P6450T
MH 208V CWI
V90U7621
PS MH 277V Opti-Wave
V90Y1912T
HPS 480V CWA
V90Y6413T
MH 480V CWA
V90Y7612T
PS MH 480V CWA
V90Z6450T
MH 600V CWI
V90C2050
HPS TRI CWI
OPE450HF
Ventronic 277V
OPHM-2-450U PS MH 277V Opti-Wave Housing
OPHM-3-450D(x) PS MH QUAD HX Housing
OPHM-3-450Y PS MH 480V HX Housing
V90D8512
PS MH QUAD CWA
V90D8530
PS MH QUAD HX
V90J8511
PS MH TRI CWA
V90J8530
PS MH TRI HX
V90U8521
PS MH 277V Opti-Wave
V90Y8512T
PS MH 480V CWA
V90Y8530T
PS MH 480V HX
OPHM-2-575U PS MH 277V Opti-Wave Housing
OPHM-3-575D(x) PS MH QUAD HX Housing
OPHM-3-575Y PS MH 480V HX Housing
V90D5530
PS MH QUAD HX
V90J5530
PS MH TRI HX
V90U5521
PS MH Opti-Wave
V90Y5530T
PS MH 480V HX
V90D2111
HPS QUAD CWA
V90D9610
PS MH QUAD CWA
V90Y9610T
PS MH CWA
OPHM-2-875Y PS MH 480V Opti-Wave Housing
OPHM-1-875Y PS MH 480V CWA Housing
OPHM-1-875D(x) PS MH QUAD CWA Housing
V90D8611
PS MH QUAD CWA
V90D8612
PS MH QUAD CWA
V90J8611
PS MH TRI CWA
V90Y8611T
PS MH CWA
V90Y8612T
PS MH CWA
V90Y8620
PS MH 480V Opti-Wave
Catalog Page
Section
#
Part
Watts Number
Product
Description
Catalog Page
Section
#
NW,Uni-Form,System 17,34,42
Systems
43
Systems
43
Systems
43
HPS
61
HPS
61
Probe Start
57
Probe Start
57
Probe Start
57
Uni-Form
72
HPS
61
Probe Start
57
HPS
61
Probe Start
57
NW,Uni-Form 17,34
HPS
61
Probe Start
57
NW,Uni-Form 17,34
HPS
61
Probe Start
57
NW,Uni-Form 17,34
Probe Start
57
HPS
61
NW,Uni-Form,System 17,35,42
Systems
43
Systems
43
Systems
43
Uni-Form
74
Uni-Form
74
Uni-Form
74
Uni-Form
74
Uni-Form
74
Uni-Form
74
Uni-Form
74
Systems
43
Systems
43
Systems
43
Uni-Form
75
Uni-Form
75
Uni-Form
75
Uni-Form
75
HPS
61
NW,Uni-Form 55
NW,Uni-Form 55
Systems
43
Systems
43
Systems
43
Uni-Form
76
Uni-Form
76
Uni-Form
76
Uni-Form
76
Uni-Form
76
Uni-Form
76
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1500
1500
1650
1650
2000
HPS QUAD CWA
HPS QUAD CWA
HPS QUAD CWA
MH QUAD CWA
MH QUAD CWA
MH QUAD CWA
PS MH QUAD CWA
PS MH QUAD CWA
HPS DUAL CWI
MH DUAL CWI
HPS TRI CWA
MH TRI CWA
PS MH TRI CWA
MH 208V CWI
HPS 480V CWA
MH 480V CWA
MH 480V CWA
PS MH 480V CWA
PS MH CWA
HPS 600V CWI
MH 600V CWI
MH QUAD CWA
MH 480V CWA
MH TRI CWA
MH TRI CWA
MH 480V CWA
HPS
HPS
HPS
Probe Start
Probe Start
Probe Start
Uni-Form
Uni-Form
HPS
Probe Start
HPS
Probe Start
Uni-Form
Probe Start
HPS
Probe Start
Probe Start
Uni-Form
Uni-Form
HPS
Probe Start
Probe Start
Probe Start
Probe Start
Probe Start
Probe Start
V90D2310
V90D2311
V90D2315
V90D6514
V90D6516
V90D6517
V90D7810
V90D7811
V90E2353
V90E6550
V90J2310
V90J6514
V90J7810
V90P6550T
V90Y2311T
V90Y6514T
V90Y6517T
V90Y7810T
V90Y7811T
V90Z2353
V90Z6550
V90D6612
V90Y6612T
V90AA6910
V90C6910
V90Y6810
61
61
61
57
57
57
77
77
61
57
61
57
77
57
61
57
57
77
77
61
57
57
57
57
57
57
Product
Index
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Product
Index
79
= Venture’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007
Warranty Information
ADDITIONAL INFORMATION
Limited Warranty on Lamps:
For years, most lamp manufacturers have used typical
life expectancy as the basis for lamp replacements
under warranty. The manufacturer understands the
parameters involved in life expectancy and also uses
typical life expectancy curves as part of their lamp
warranty. The manufacturer is aware of their
customers’ needs and offers additional warranty
protection.
Warranty
1. Upon receipt and/or initial installation by the
customer, the manufacturer will replace any lamp
determined to be defective in materials,
workmanship or proper operating parameters.
2. HIDirect will replace any lamp that fails within one
year from the purchase date (based on 5000 hrs/yr
operation) when the failure is determined to be lamp
related. (Applies to lamps with life ratings of greater
than 7500 hours.)
3. During economic life, HIDirect will supply
replacement lamps for failed lamps in excess of the
failure rate projected by life expectancy curves when
the lamps are operated correctly and in accordance
with the guidelines outlined in this technical guide.
Lamp Performance
All performance ratings are based on lamp testing at
rated watts, under controlled conditions, using primary
AC electrical circuits with the highest quality auxiliary
equipment. The performance of any lamp may vary
somewhat under typical service conditions. All lamp
specifications and ratings are subject to change without
notice.
Product
Index
Limited Warranty on Ballasts:
Ballast products are warrantied free from
manufacturing and workmanship defects for a period of
two years from the date of shipment. During this
period, HIDirect will, at its option, repair or replace
ballast products which prove to be defective or out of
specification. This warranty is granted by the
manufacturer only to the original purchaser or first
end-user of such ballast products.
This warranty is conditional upon installation,
maintenance and operation in accordance with the
manufacturer’s instructions and specifications set forth
in the purchase order or contract at the time of order
and in accordance with the standards of The National
Electric Code (NEC), Underwriters’ Laboratory, Inc. (UL)
and the American National Standards Institute (ANSI)
and, in Canada, with the standards of the Canadian
Standards Association (CSA). Damage by misuse or
abnormal conditions of storage, installation,
maintenance or operation, including, but not limited to,
excessive temperatures or evidence of partial or
complete disassembly beyond normal maintenance or
expansion procedure void this warranty in its entirety.
The conditions of any tests performed concerning any
ballast product claimed to be defective in accordance
with the terms of this warranty shall be mutually agreed
upon in writing between the original purchaser or first
end-user and HIDirect and HIDirect may be represented
at any such test.
No implied statutory warranty of merchantability or
fitness for a particular purpose shall apply beyond the
afore-mentioned warranty period. This warranty
excludes other warranties, expressed or implied and is
the exclusive remedy of the claimant. HIDirect shall not
be liable for any special, indirect or consequential
damages. HIDirect’s liability on any claim of any kind,
nature or description arising out of, resulting from or
concerning any aspect of this warranty agreement or
from the product or services furnished hereunder shall
not exceed the price of the specific ballast or ballasts
which give rise to the claim. For warranty service or
repair, the buyer shall prepay all shipping charges to
HIDirect and HIDirect shall pay shipping charges to
80
return the repaired or replaced item to the buyer.
However, the buyer shall pay all shipping charges,
duties and taxes for products returned to HIDirect from a
country other than that of the United States of America.
Product replacement/liability limits
The foregoing warranty shall be the sole and exclusive
remedy of the purchaser and HIDirect’s sole and
exclusive remedy to the purchaser. NO WARRANTY
OF FITNESS FOR ANY SPECIFIC OR PARTICULAR
PURPOSE IS MADE OR IS TO BE IMPLIED. NO OTHER
WARRANTY APPLIES. HIDirect will not, under any
circumstance, whether as a result of breach of contract,
warranty tort or otherwise, be liable for any costs or
damages, including lost profits or revenues, incidental,
special or consequential damages.
Some states or provinces do not allow the exclusion or
limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you
may also have other rights which may vary from state
to state and province to province. No distributor,
salesperson, dealer, retailer or other representative has
the authority to change or modify this warranty, either
orally or in writing, in any respect.
Dimming Policy
Warranty policy on the dimming of HIDirect or Venture
Lighting metal halide lamps:
SCOPE: The manufacturer’s metal halide lamps can only
be step or bi-level dimmed by the switched capacitance
method on a CWA or CWI ballast. Line voltage and
electronic dimming systems are not covered by this
policy. Contact HIDirect for further information.
WARRANTY POLICY: HIDirect agrees to extend a
limited one-year warranty on lamp life to lamps
operated on dimmable control gear, provided the
following conditions are met:
1) A lamp must never be started by a ballast in the
dimmed operating mode.
2) During any lamp start (cold or hot restart), the
ballast must meet all of the requirements for starting
and sustaining a lamp described in ANSI lamp
standard C78.43.
3) The lamp must be allowed to warm up for at least
10 minutes after the lamp has started (20 minutes for
lamp wattages greater than 450). Only then can
dimming begin.
4) For system design purposes an ANSI reference lamp
cannot be dimmed below 50% of the rated lamp
wattage at 90% input voltage for CWA or CWI
ballasts.
5) Operating position requirements are
• Base up ±15°, only, for probe start or pulse start
lamps designated as U, BU, HBU
• Vertical ±15°, only, for pulse start lamps
designated as U, V
• Base down ±15°, only, for pulse start lamps
designated as BD, HBD
• No Horizontal dimming.
6) The ballast input voltage must be kept within the
accepted line voltage range for the ballast type
(±10% for CWA or CWI ballasts) at all times in dim
and full power modes
7) The dimming device should not allow the ballast
current crest factor to exceed 1.8.
Ballasts/Lamps
STANDARD WARRANTY
Product Type
50, 70, 100, 125
150, 175, 200, 250
320, 350, 400, 450
575, 775, 875
Magnetic Ballasts
Electronic Ballasts
“ONE CALL” WARRANTY
“One Call” limited warranty program is first in the
industry in its comprehensive system coverage. It
doubles the warranty period on lamps and ballasts
purchased and installed as part of the Uni-Form® pulse
start system. Since HIDirect manufactures the lamps and
ballasts, customers who purchase a complete system
need to make only “one call” to receive full service on
any component from HIDirect’s team of technical
experts. This means no finger pointing; one source, one
call to 1-800-965-2677 for service. Technical assistants
will answer all your questions.
Warranty Activation/Service Claims –
You Must Register
To activate the One Call warranty, HIDirect must receive
a completed registration form within 30 days after
installation of the Uni-Form system. You may complete
the registration form included in this catalog or call our
toll-free number to have the form sent to you. HIDirect
will send an acknowledgment for each registration
received. For information, service, technical assistance
or replacement claims, call the One Call toll-free
number at 1-800-965-2677. If a lamp or ballast in the
Uni-Form system fails to operate within the warranty
period (based on a maximum 5000hrs./yr operation
and normal mortality), HIDirect will provide a free
replacement. No reimbursement for labor is made for
lamp or ballast replacement.
Warranty Terms And Conditions
The One Call warranty covers lamps and ballasts
purchased and installed together as a Uni-Form system.
The installation must be operated under proper
environmental conditions and in accordance with
current National Electrical Code, Underwriters
Laboratory and ANSI specifications. This warranty will
be voided if conditions demonstrate abnormal use or
stress, such as operating temperatures in excess of
maximum rated temperatures, under/over voltage
conditions, excessive switching cycles or operating
hours or improper lamp or ballast installation. The
lamp warranty will be voided if lamps are replaced
with any other manufacturer’s lamps. The entire
warranty will be voided if ballasts are replaced with
any other manufacturer’s ballasts.
Product Replacement/liability Limits
The foregoing warranty shall be the sole and exclusive
remedy of the purchaser and HIDirect’s sole and
exclusive remedy to the purchaser. NO WARRANTY OF
FITNESS FOR ANY SPECIFIC OR PARTICULAR PURPOSE
IS MADE OR IS TO BE IMPLIED. NO OTHER
WARRANTY APPLIES. HIDirect will not, under any
circumstance, whether as a result of breach of contract
or warranty tort, or otherwise, be liable for any costs or
damages, including lost profits or revenues, incidental,
special or consequential damages.
HIDirect reserves the right to examine all failed lamps
and ballasts purchased as part of a Uni-Form system.
Some states or provinces do not allow the exclusion or
limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
No distributor, salesperson, dealer, retailer or other
representative has the authority to change or modify
this warranty, either orally or in writing, in any respect.
This warranty gives you specific legal rights and you
may also have other rights which may vary from state
to state and province to province.
Standard “One Call”
Warranty
System
Period
Warranty
One Year
One Year
One Year
Two Years
One Year
Two Years
One Year
Two Years
Two Years
Five Years
Two Years
Three Years
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Warranty Information
ADDITIONAL INFORMATION
“One Call” System Warranty Registration
To receive warranty service, register any installation featuring Uni-Form® pulse start systems.
Warranty coverage begins on the date of installation. Call 1-800-965-2677 with any questions.
Complete and Return To:
HIDirect
10295 Philipp Parkway
Sttreetsboro, Ohio 44241
Complete and Fax To:
HIDirect
1-800-865-2677
Rep Agency:
Contact:
Distributor:
Contact:
Installation Information
Today’s Date:
Job Name:
Location Name:
Installation Date:
Street Address:
City:
State/Province:
Contact Name:
Zip/Postal Code:
Phone:
Description and Product # (as shown on product packaging)
Fixture
Type
Manufacturer
Qty
Lamp
Product #
Lamp
Description
Ballast
Product #
Ballast
Description
(Optional) Restrike Controls
Product Number __________________________ Quantity _________________________
Fixture Description and Item#: ______________________________________________________________________________
Note: Must include Uni-Form® pulse start lamps and ballasts purchased together as a system to qualify. Sales order from distributor and
invoice from fixture manufacturer, if new fixture is involved, must accompany this form to validate the system warranty.
Note: This form must be completed and returned to HIDirect within 30 days of installastion.
81
800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com
Your One-Stop Connection For Replacement
and Retrofit Lighting Solutions!
Order our most popular products
on-line, around the clock!
Call 800-965-2677
Fax 800-865-2677
HIDirect.com
© 2008 HIDirect
HIDirect is a registered trademark of HIDirect. Uni-Form and Venture are registered trademarks of Venture Lighting
HID-0220C1-0808
Download