Your One-Stop Connection For Replacement and Retrofit Lighting Solutions! Lamps Ballasts HID Lighting Product Catalog Fixtures Applications Introduction Natural White™ Horizontal PS Lamps UNI-FORM® Systems Retrofit Systems Specialty Lamps HPS Lamps Probe Start and Ballasts MH Systems Reference Guide Product Index Table of Contents INTRODUCTION INFORMATION Introduction Who is HIDirect . . . . . . . . . . . . . . . . . . . . .1 Mission statement and how to order . . . . . . . .2 VIP program . . . . . . . . . . . . . . . . . . . . . . . .2 Applications Shopping mall lighting . . . . . . . . . . . . . . . . .4 Grocery store lighting . . . . . . . . . . . . . . . . .5 Automobile Dealership lighting . . . . . . . . . . .6 Gymnasium lighting . . . . . . . . . . . . . . . . . . .7 Outdoor sports lighting . . . . . . . . . . . . . . . . .8 Arena lighting . . . . . . . . . . . . . . . . . . . . . .9 Highbay industrial lighting . . . . . . . . . . . . .10 Manufacturing lighting . . . . . . . . . . . . . . . .11 Parking garage lighting . . . . . . . . . . . . . . .12 Parking lot and site lighting . . . . . . . . . . . . .13 Guide of product by application . . . . . . . . .14 Natural White® Pulse Start Systems 90% mean lumens, high CRI and high color temperature (5000K) product that delivers the same color as sunlight Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Retrofit System Solutions Electronic ballast housings . . . . . . . . . . . . .42 Magnetic ballast housings . . . . . . . . . . . . . .43 Track lighting systems . . . . . . . . . . . . . . . . .44 Specialty Lamps Energy Master® . . . . . . . . . . . . . White-Lux® . . . . . . . . . . . . . . . . High wattage/Sports lighting . . . Tubular lamps . . . . . . . . . . . . . . Double ended and G12 lamps . . High wattage double ended lamps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 .48 .49 .50 .51 .52 Probe Start Metal Halide Lamps . . . . . . . . . . . . . . . . . . . . . . . . . . .54 Ballasts . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Wiring diagrams . . . . . . . . . . . . . . . . . . . .58 HPS Lamps and Ballasts High Pressure Sodium lamps . . . . . . . . . . . .59 High Pressure Sodium ballasts . . . . . . . . . . .60 Wiring diagrams . . . . . . . . . . . . . . . . . . . .62 Horizontal Guide Pulse Start Systems Reference Trouble Shooting Guide . . . . . . . . . . . . .64-65 The first pulse start systems designed for horizontal operation 200, 250, 320, 350 and 400 watt . . . . . . .20 Uni-Form® Pulse Start Systems 50 watt . . . . . . . . . . . . . . . . . . . . . . . . . .22 70 watt . . . . . . . . . . . . . . . . . . . . . . . . . .23 100 watt . . . . . . . . . . . . . . . . . . . . . . . . .24 125 watt . . . . . . . . . . . . . . . . . . . . . . . . .25 150 watt . . . . . . . . . . . . . . . . . . . . . . . . .26 175 watt . . . . . . . . . . . . . . . . . . . . . . . . .27 200 watt . . . . . . . . . . . . . . . . . . . . . . . . .28 250 watt . . . . . . . . . . . . . . . . . . . . . . . . .29 320 watt . . . . . . . . . . . . . . . . . . . . . . .30-31 350 watt . . . . . . . . . . . . . . . . . . . . . . .32-33 400 watt . . . . . . . . . . . . . . . . . . . . . . . . .34 450 watt . . . . . . . . . . . . . . . . . . . . . . . . .35 575 watt . . . . . . . . . . . . . . . . . . . . . . . . .36 875 watt . . . . . . . . . . . . . . . . . . . . . . . . .37 1000 watt . . . . . . . . . . . . . . . . . . . . . . . . .38 Go Green: Retrofit and Save . . . . . . . . . . . .39 Wiring diagrams . . . . . . . . . . . . . . . . . . . .40 Replacement Sockets . . . . . . . . . . . . . . . . . . .66 Replacement Ignitors and Capacitors . . . . . . . .67 Capacitor and Ignitor Diagrams . . . . . . . . .68 Lamp Shapes and Bases . . . . . . . . . . . . . . .68 Ballast Brackets . . . . . . . . . . . . . . . . . . . . .69 Glossary . . . . . . . . . . . . . . . . . . . . . . .70-71 Lamp and Ballast Cross-Reference . . . . . .72-74 Product Index Product Description Code Explanation . . . . .75 Lamps . . . . . . . . . . . . . . . . . . . . . . . . .76-77 Ballasts . . . . . . . . . . . . . . . . . . . . . . . .78-79 Warranty information and dimming policy . .80 “One Call” Warranty registration form . . . . .81 Photo credits: . . . . . . . . . . . . . . . . . .Page Number(s) © Steve Mulé . . . . . . . . . . . . . . . . . . . . . . . . . .25,51 © Vance Roth . . . . . . . . . . . . . . . . . . . . . . . . .8,49C © Doug Salin . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 © Doug Walker . . . . . . . . . . . . . . . . . . . . . . . . .49B © Héctor Armando Herrera . . . . . . . . . . . . . . .14,19 Courtesy of Electrotech . . . . . . . . . . . . . . . . . . . . .52 Courtesy of The Minnesota Wild . . . . . . . . . . . . . . . .9 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Introduction Who is HIDirect? INTRODUCTION INFORMATION HIDirect Benefits / Features We’re your best choice for high intensity discharge (HID) replacement lighting products and services at the best price, including metal halide and HPS. We offer the largest selection of in-stock metal halide products and numerous HPS products, including replacements for GE, Philips, Osram/Sylvania and Venture. Our vast selection of standard probe start and pulse start metal halide lamps and ballasts and HPS lighting is ideal for any application, including: • Commercial • Factories • Industrial • Warehouses • Retail • Signs • Security • Canopies • Parking Areas • Landscape • Sports Facilities and more! • Large variety - Over 1000 types of metal halide and HPS lamps and ballast kits • Retrofit Kits available • Competitive pricing • Knowledgeable customer service representatives • Fast Service. Orders in by 3pm EST ship same day for in-stock products! (next day delivery also available) • Get an extra 5% off your purchase using Visa, MC or AMEX HIDirect’s Headquarters Streetsboro, Ohio, U.S.A. • No-fee recycling service (ask for details) • FREE volume shipping, ask for details • No minimum order requirement • Ask about our VIP program Why HIDirect? HIDirect is the factory-direct distributor of the world’s leading designed metal halide lighting systems, including Uni-Form® pulse start metal halide systems with the formed body arc tube. We ship all in-stock items the same day you place your order. You’ll have access to the largest selection of standard probe start, pulse start, specialty and energy-saving lamps and ballasts at the best prices. “I love working with HIDirect. When I can buy factory-direct pricing on a great product, that’s what it’s all about. Who doesn’t want to save money? HIDirect cuts out the middle man and I can buy my lamps straight from them.” -Satisfied HIDirect Customer Factory Direct 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 1 Introduction Benefits Who is HIDirect? of HIDirect INTRODUCTION INFORMATION Our Commitment to You Our Mission Statement We’re specialists in the HID lamp and ballast market and we promise to supply the right lamp and ballast for your application. Our knowledgeable customer service representatives guarantee your satisfaction. To be the best specialty lighting supplier in North America of metal halide and HID systems including lamps, ballasts, fixtures, ignitors and capacitors, providing: Greener Ballasts HIDirect supports the green energy initiatives of California Title 20 and the Energy Independence & Security Act of 2007, which mandate that metal halide fixtures manufactured in 2009 must contain pulse start ballasts that are at least 88% efficient. We agree with the need to move away from less energy efficient standard probe-start technology and strongly recommend that more efficient and “green” pulse start technology be embraced by all of our customers immediately. Our compliant ballasts have been designated by the green leaf by the product number. For more information about this legislation, visit our website. 2 • The highest quality value-added customer solutions • Advanced products • Fastest delivery • Knowledgeable customer service staff • Competitive prices How to Order Not only does HIDirect give you expert service and competitive pricing, we’re here longer to serve your HID needs better. We’ve extended our phone hours to accommodate any schedule! We can be reached toll-free at 800-965-2677 from 7:00 a.m. to 5:00 p.m., Monday - Friday EST. Or, you can reach us anytime by fax at 800-865-2677 Or online at HIDirect.com! Email us at custserve@hidirect.com Savings 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Case Studies APPLICATION SPECIFIC PRODUCT GUIDE Creating the Right System For Any Application Looking For an Application? This section shows the many uses and advantages of HIDirect’s metal halide lighting products, such as Uni-Form® pulse start lamps, Opti-Wave® ballasts, sports and specialty lighting products. Shopping Mall Lighting . . . Grocery Store Lighting . . . Auto Dealership Lighting . . Gymnasium Lighting . . . . . Outdoor Sports Lighting . . Arena Lighting . . . . . . . . Highbay Industrial Lighting Manufacturing Lighting . . . Parking Garage Lighting . . Parking Lot Lighting . . . . . Street Lighting . . . . . . . . . The wide variety of applications and possibilities, in combination with benefits such as energy savings and better quality light, HIDirect is your clear choice for metal halide products. Application-Product Selection Guide System Page Applications Application Type .Various Wattages . . . . .4 .320W . . . . . . . . . . . .5 .Various Wattages . . . . .6 .450W . . . . . . . . . . . .7 .Various Wattages . . . . .8 .1000W . . . . . . . . . . .9 .875W . . . . . . . . . . .10 .450W . . . . . . . . . . .11 .200W . . . . . . . . . . .12 .400W . . . . . . . . . . .13 .Horizontal pulse start .14 Looking for a light source for a particular application? This application-product guide is your source for finding the right Uni-Form® pulse start metal halide system. Pulse Start System Wattage 50 70 100 125 150 175 200 250 320 350 400 450 575 775 875 1000 Architectural Applications Retail/Big Box Grocery Story on page 5 Airport Security • Parking Garage Story on page 12 Retail Auto Lots Story on page 6 Roadways Gas Station Canopy Lowbay Industrial Highbay Industrial Story on page10 Aircraft Hangers Food Processing Hazardous Locations Indoor Sports Story on page 7 Sign Lighting/Billboards Landscape • Lecture Halls Convention Centers Site/Parking Lot Story on page 13 Warehouse • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Luminaire Applications Lowbay Highbay Wallpack Floodlight Canopy Light Sign Lighter Hazardous Vertical Lamp Area Cutoff Horizontal Lamp Shoebox Recessed Downlight Indirect Lighting Well Lights Bollards Sconce Electronic Dimming • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Applications 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 3 Uni-Form Systems Case Study ® Applications APPLICATION SPECIFIC PRODUCT GUIDE Shopping Mall More Light and Less Energy “SuperMall of The Great Northwest”, located just east of Tacoma in Auburn, WA is an over one million square foot shopping complex serving over 7,000,000 customers annually. Opened in 1995, SuperMall is just 1 of 24 malls owned and operated by Glimcher Realty Trust, which is headquartered in Columbus, Ohio. what the Uni-Form pulse Glimcher Realty Trust malls are in the process of updating lighting in all areas, and recently began this process with SuperMall of the Great Northwest. Paul Hensley, operations director of the mall, was looking for “more uniform brighter light, with energy savings”. SuperMall turned to United Lamp Supply of Tacoma, WA. Karl Willard, Sales Manager for United Lamp, with more than 20 years of lighting experience himself, managed the project from beginning to end. start product has delivered. Challenges and Results We’re very satisfied. Initially, (240) 1000W standard probe start lamps and ballasts were replaced by the energy efficient 875W pulse start lamps and ballasts in the mall’s various parking lots. The 875W systems saved 155 watts per fixture and footcandle readings were a full 37% higher than with the previous systems. Since the photometrics of the lamps were the same, the existing parking lot poles and fixtures did not need to be changed, significantly reducing installation costs. “We were looking for more uniform brighter light, with energy savings and that’s ” -Paul Hensley, Operations Director 4 In the food court areas of the mall, (91) 250W standard probe start lamps and ballasts were replaced with 200W Uni-Form® pulse start systems. (35) 400W standard probe start lamps and ballasts were replaced with 320W Uni-Form pulse start systems. In the various entrances of the mall, (32) 175W standard probe start lamps and ballasts were replaced with 150W Uni-Form pulse start lamps and ballasts. Paul Hensley is happy to report that the initial introduction to each mall entrance now plays a more positive role in the overall shopping experience for SuperMall customers. Saving from Rebates As incentive for using this energy efficient technology, SuperMall received an energy rebate from the local utility, Puget Sound Energy. The mall received an up-front rebate of $156,000.00, which enabled them to reduce the pay-back period in half. Benefits: • Brighter, better quality lighting • Energy Savings • Energy utility rebates, reducing pay-back period • Excellent color uniformity The Uni-Form® pulse start 150W, 200W, 320W, 875W details can be found on pages: 26, 28, 30, 37. 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Electronic 320W Case Study APPLICATION SPECIFIC PRODUCT GUIDE Applications Grocery Store The Metal Halide Innovator In grocery stores, lighting can play a significant role in assisting shoppers in locating items on shelves and in highlighting important features of those items. Attractive displays encourage customers to browse and buy, leaving them satisfied and more likely to return. The grocery store industry is extremely competitive, and any feature more pleasing to a customer can mean the difference between success and failure during the shopping experience. Grocery stores with lights that are bright with an appealing color are more likely to entice customers to shop at their location rather than at a store with lighting that creates a gloomy atmosphere. In the example pictured, a Charlotte, NC grocery store took advantage of HIDirect’s HF electronic ballast housing/fixture. This choice enabled them to not only display their grocery store items in the most appealing manner possible, but also to achieve significant energy savings in the process. Many grocery store chains are looking for even greater color rendering of their stocked items, and are choosing Natural White® pulse start products. The high 90+ color rendering (CRI) and 5000K color temperature of this product line displays grocery items in the best possible light, providing a natural sunlight atmosphere to any store location. Color sensitive items such as produce and meats are displayed in a much brighter and appealing light. Benefits: • Improved lumen maintenance on electronic system • Excellent color uniformity • With electronic system, 2 year 100% lamp warranty The Uni-Form® 320W details can be found on page 16 5 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Natural White Case Study ® Applications APPLICATION SPECIFIC PRODUCT GUIDE Auto Dealership Whiter Light and Less Energy New Car Pickup Area The Classic Auto Group, located in Northeast Ohio, offers a huge variety in automobile choices ranging from Chevrolet to Lexus and Cadillac. At their Toyota dealership, they replaced outdated standard probe start metal halide technology with new state-of-the-art Natural White® pulse start technology. Classic also replaced a variety of fixtures in their new car pickup area with (22) low wattage track lighting systems. As a Natural White product, HIDirect’s MR16’s offer high energy efficiency, high color rendering and maximum light “punch”, all in a compact size with tight beam control to put the light right where you want it. Classic is extremely pleased with its new Natural White lighting and all the benefits it has brought to the Mentor dealership. Car Lot Lighting “We’re extremely pleased with the lighting. At night, our dealership shines like a diamond. From just the better lighting alone, I’ll sell more cars. ” -Bob Ringo, Classic Automotive Group 6 Classic replaced (121) 1000-watt standard probe start lamps and ballasts in their Mentor car lot with 775-watt Natural White lamps and ballasts. This resulted in a huge decrease in energy consumption of over 25%. The lot draws attention to the dealership by all who pass due to the brighter and “whiter” lighting. Service Bays and Showrooms In its service bay area, Classic replaced (56) 400W standard probe start lamps and ballasts with the same number of energy saving retrofit 450W Natural White pulse start systems. The light output was increased by 60%. An improved overall work atmosphere, which was more conducive to fewer servicing errors, was achieved. In the showroom, (24) 400W standard probe start lamps and ballasts were replaced with 400W Natural White pulse start lamps and ballasts. Benefits: • High CRI lighting, 90+ with daylight color: 5000K CCT, which is perfect for daylight harvesting • 90% mean lumens - A first in HID industry! • With electronic system, 2 year 100% lamp warranty Comparisons Quantity of Lighting Systems Car Lot 121 Service 56 Bay Area Showroom 26 Existing Wattage 1000W 400W 400W Upgraded Annual System Energy Wattage Savings 775W $11,616.00 290W $3,091.20 400W $1,123.20 Total: $15,830.40 Total of 25% Reduction of Energy Usage (Based on 5000 hours/year at $0.08/kWh) 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Electronic 450W Case Study APPLICATION SPECIFIC PRODUCT GUIDE Applications 50% Power Full Power Gymnasium Lighting Daylight Harvesting & Dimming of College Athletic Facility Benefits: A major university in the Southeast was looking to provide good quality white light in its gymnasium, with the ability to save energy and operating costs by dimming those lights as well as utilize cost-free daylight harvesting. • Up to 86% mean lumens By using HIDirect’s 450 watt e-Lamp® product, which is a Uni-Form® pulse start lamp optimized for use on HIDirect’s Ventronic™ electronic ballasts, the university was able to significantly reduce its overall energy consumption and operating costs. Utilizing dimming technology with the lamps allowed the facility to take advantage of the natural light of the sun through daylight harvesting. Uni-Form pulse start 450W e-Lamp benefits: • Long life: 20,000++ hours • Ballast efficiency up to 95% • Significant energy savings The Uni-Form® 450W details can be found on page 35 The university utilizes a sophisticated dimming system, capable of dimming the 450W lamps to a full 50% of power output. Over 4 different light output settings can be used for various functions, such as basketball practice would be at 75% lamp power while actual games would be lighted at full power. When dimming, the university significantly reduces its energy usage, while getting quality “free” light directly from the sun. 7 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Sports Lighting Case Study Applications APPLICATION SPECIFIC PRODUCT GUIDE Outdoor Sports Lights that Bring Their A-Game For professional, semi-professional and amateur sporting events, bright white light shining down is essential for enabling fans to view the events and their favorite teams and athletes in the best possible way. Good color rendering of lighting sources is also very important not only in effectively displaying uniform and stadium/arena colors, but also for allowing sports fans to most effectively view scoreboards and other areas that are part of outdoor venues. It is important that good lighting is maintained even during adverse weather conditions, including heat or cold. HIDirect’s metal halide lamps and ballasts are the lighting technology of choice to provide superior and bright white light, as well as excellent color rendering during all types of weather conditions. From major league baseball organizations to minor league teams, as well as for a plethora of amateur sporting venues, HIDirect’s 1500W and 1650W lamps can be focused accurately on sporting events, providing long lamp life and bright white light. As a typical example, 115 luminaires consisting of HIDirect’s 1500W horizontal sport lamps are utilized in Lelacher Park in Lowell, Massachusetts. Lelacher Park is home of the Boston Red Sox’s Class A farm team. With a seating capacity of 5,000 fans, this park also plays host to the nearby University of Lowell’s spring and fall baseball games. These lamps provide many, many hours of great lighting for a multitude of baseball contests. Benefits: • Position oriented horizontal applications up to 60° tilt • Unique cross pinch design for stable light output • High lumen output (1650 watt), 177,000 lumens and 107 lumens per watt for optimal horizontal and vertical illuminance • 3200K - 4000K color Sports Lighting lamp details can be found on page 49 8 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Sports Lighting Case Study APPLICATION SPECIFIC PRODUCT GUIDE Applications Arena Lighting HIDirect is an All Star Lighting sports and entertainment facilities such as Xcel Energy Center in St. Paul, Minnesota makes HIDirect an all-star in lighting. The 650,000 sq. ft. Xcel Energy Center is home to the National Hockey League’s Minnesota Wild, the 2004 NHL All-Star game and four World Cup of Hockey games. The NHL demands quality lighting for televising games. This includes rendering players’ jerseys in true color and adequately lighting the ice rink and fans in the arena’s first 30 rows. HIDirect’s MS 1000W/HOR/BT37/3K lamps produce the necessary 125 foot candles of vertical illumination, high color rendering and light quality. The lighting design called for 340 luminaires, but the light output produced by the lamps helped reduce that number to 280 luminaires. “They’re great lights,” said Mark Anger, director of Facilities Development for Minnesota Sports & Entertainment. HIDirect’s lamps also light the American Airlines Center, Conseco Fieldhouse, Pepsi Center, Staples Center and First Union Arena. Benefits: • Position oriented super metal halide for maximum light output • Reduced outer jacket size for precise optical control • Warm 3400K color The 1000W Horizontal lamp details can be found on page 55 “They’re great lights“ -Mark Anger, director of Facilities Development for Minnesota Sports & Entertainment. 9 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 875W System Case Study Applications APPLICATION SPECIFIC PRODUCT GUIDE Highbay Industrial “We’re extremely pleased with the changes resulting from the lighting throughout the facility. We were able to achieve our goals. It was a doubling of the light output with nearly half the number of lamps. ” The Steel Mill’s Electrical Maintenance Manager 10 Improving Worker Safety Making a Positive Difference A 1.3 million square foot steel mill located near Gary, Indiana is aware of the importance to the ecology of the surrounding countryside, and works continuously to improve its operations to become more environmentally friendly. In November of 2006, they looked into replacing hundreds of their older and energy inefficient standard probe start metal halide, mercury vapor and high pressure sodium lamps with a more energy efficient lighting technology, hoping to significantly reduce energy usage and improve safety and the productivity of the workers. Worker attitudes improved noticeably once the new lighting systems were installed. Management received thanks from workers, and complaints of the previous lighting stopped. Thanks to the improved lighting, the mill experienced one of its safest years in their over 40 year history! The plant’s operations manager noted, “the new lights resulted in doubling the light output with nearly half the number of lamps”. For further energy savings, remote lighting controls were utilized to turn various lamps on and off as needed in specific areas of the mill. They were utilizing (1190) 1000 watt standard probe start metal halide, (340) 1000 watt mercury vapor and (170) 400 watt high pressure sodium high bay lights. Choosing HIDirect’s 875 watt pulse start system, they were able to reduce the fixture count by 44%, resulting in a 50% energy savings. In various parts of the mill, entire rows of lamps could now be eliminated due to the exceptional light output of the HIDirect® lamps! Overall, (952) 875 watt pulse start metal halide systems replaced the original (1700) systems. They were able to reduce the total number of lamps, ballasts and fixtures resulting in a reduction of inventory and lighting maintenance costs. Benefits: • Twice the light • Annual savings of over $400,000 • Reduction of Energy Usage by 50% Comparisons 875 Watt Pulse Start vs Previous Systems 952 Number of Fixtures 1700 20,000+ Lamp Life Hours 12,000 50 Average footcandles 14 7.8 Million Energy Consumption 15.1 Million for Lighting (kWh) $400,000 Total Annual Savings 0 for the one facility 50% Energy Savings 0 The pulse start 875W details can be found on page 37 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 350W Natural White Case Study ® APPLICATION SPECIFIC PRODUCT GUIDE Applications Manufacturing Improved Light Quality & Saved Energy Existing 400W high pressure sodium (HPS) lamps utilized at a Northeast aircraft manufacturer’s facility was not delivering the quality or light level necessary for most manufacturing operations. The typical “yellow” light provided by HPS lamps was ineffective at rendering colors accurately on the production floor, resulting in poor quality and overall productivity. In addition, this existing lighting system was very energy inefficient, resulting in higher than acceptable monthly energy costs. A local lighting specialist recommended utilizing HIDirect’s 350W Natural White® pulse start metal halide lamps in combination with electronic ballasts as the ideal solution. The light from Natural White lamps mimics that from natural sunlight, resulting in a brighter and more natural looking work space. Benefits: • Energy savings: over 50% improvement in mean lumens per watt vs. 400 watt standard probe start metal halide system • Long life: 20,000+ hours • Improved color uniformity • Optimized lamp/ballast systems for superior performance • Higher CRI of 90+ over HPS lamps at 22 CRI The 350W Natural White lamp details can be found on page 16 In switching to Natural White pulse start technology, this manufacturer immediately obtained the brightest and best possible lighting system available, while also achieving good energy savings. As an added bonus, this system provided 90% lumen maintenance, meaning that the Natural White lamps are providing nearly the same higher light output years after their initial installation. 11 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Uni-Form Systems Case Study ® Applications APPLICATION SPECIFIC PRODUCT GUIDE Parking Garage Minneapolis-St. Paul International Airport, one of the busiest airports in the world, recently completed a comprehensive lighting retrofit in its parking garage, switching from standard probe start metal halide lamps to more energy efficient Uni-Form® pulse start metal halide lamps. The decision to switch to this technology was made even easier when the local power company, Xcel Energy, offered the airport a substantial rebate for retrofitting with pulse start technology. HIDirect’s energy saving 125 and 150 watt Uni-Form pulse start metal halide lamps were the lamps of choice to retrofit the current system. Ready to Relamp Brighter Future for Airport After many years of constant use, the 175, 250, and 400watt standard probe start metal halide lamps in the airport parking garage needed relamping. Due to tight budget constraints in the air travel industry, energy savings was a key consideration in specifying the new lamps, and airport management did not want to sacrifice light output to cut energy costs. The six month project involved the installation of more than 4,000 lamps and ballasts in the parking garage structure. Airport management was ecstatic with the result of the retrofit: “We doubled our light levels!” said Bob Litke, Electrical/General Foreman for the Metropolitan Airports Commission,“ and with the substantial energysavings, we should begin seeing a return on our investment in only one year.” By switching to new Uni-Form pulse start metal halide technology, the airport would see immediate benefits. These benefits ranged from large yearly energy savings, reduced maintenance costs based upon the extended lamp life, increased light output, and better color rendering for improved security and easier identification of the customers’ cars. Uni-Form pulse start metal halide lamps were recommended. They outperform standard probe start metal halide lamps by providing energy savings, long life (20,000+ hours) and increased light output over the life of the system. Benefits: • Energy savings • Longer lamp life: reduced maintenance costs • Double the light output • Better color rendering for improved security and easier identification of the customers’ cars The 125W Uni-Form lamp details can be found on page 25. The 150W Uni-Form lamp details can be found on page 26. 12 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 775W Natural White Case Study ® APPLICATION SPECIFIC PRODUCT GUIDE Applications Parking Lots More Light and Less Energy In Murfreesboro, TN, located 40 miles south of Nashville, Innsbrooke Plaza is a 150,000 square foot shopping complex. In early 2008, Inland Continental Property Management, the developer of Innsbrooke Plaza, was looking to improve the overall lighting output in the parking areas of the mall. The existing lighting consisted of (6) lighting poles 39’ in height, each of which held (4) 1000W high pressure sodium lamps in vertical semicutoff luminaires. High pressure sodium lamps cast a yellowish light, making it difficult for shoppers to see well at night, and provide very poor color rendering, making the identification of one’s automobile in the lot difficult as well. To achieve the goals of improved lighting levels and quality, and reduced energy consumption and maintenance, HIDirect’s 775W Natural White® pulse start metal halide systems were used in combination with sharp cutoff luminaires in a one-for-one replacement of the high pressure sodium systems. Natural White lamps provide whiter and brighter light due to superior color rendering; a color temperature of 5000K essentially matches the color of natural sunlight. By switching to this much lower wattage option, Innsbrooke was able to achieve an incredible reduction of 255 watts per fixture, resulting in 23% less energy consumption, and the superior “white” light output of the 775 watt lamps increased footcandles in the parking lot by 60%! Inland and Innsbrooke Plaza are pleased with their new “whiter” Natural White pulse start lamps and ballasts. Not only were all initial goals of improved light levels, reduced energy consumption and improved lighting maintenance met and surpassed, yet in addition, Innsbrooke is now benefiting from an annual energy savings of $4,000! Benefits: • High CRI lighting, 90+ with daylight color: 5000K Correlated Color Temperature • 90% mean lumens • Energy savings of 255 watts per fixture • Lower maintenance costs Comparisons Natural White® 1000W High 775W vs Pressure Sodium 24 Number of Fixtures 24 845 System Watts 1100 90+ CRI 23 5000K Color Temperature 2200K (Blue-White) (Yellow-Orange) $4,000/year Savings 0 25% Energy Savings 0 The 775W Natural White system details can be found on page 16. 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 13 Uni-Form Systems Case Study ® Applications APPLICATION SPECIFIC PRODUCT GUIDE Street Lighting The Metal Halide Innovator Mexico City, with its more than 20 million residents, was in search of street lighting, which would provide better visibility at night. With a preponderance of high pressure sodium lamps used, HPS may have long life, but their distinctive “yellow” glow reduces overall visibility during the night, creating public safety and security issues, a major concern of one municipality. “It’s a great investment not only in the city’s beauty but in its public security. The new lighting technology has changed the city’s panorama ” completely. -Antonio Gershensen Public Lighting Director of Mexico City 14 In the summer of 2005 the Mexico City municipality utilized 36,000 of HIDirect’s 200 watt Uni-Form® Horizontal pulse start lamps for street lights. About 60% of these lamps were used to retrofit existing HPS lamps, while the remaining lamps were for entirely new installations. “It’s a great investment not only in the city’s beauty but in its public security. The new lighting technology has changed the city’s panorama completely”, stated Antonio Gershensen, Public Lighting Director of Mexico City. Studies have shown that metal halide lighting, which utilizes more visible “white” light, can have a visibility effectiveness of up to six times that of HPS when used at night. Gershensen further noted: “This kind of lamp gives 30% more light than the old yellow ones (HPS), they have longer life and they represent an important development in color fidelity. The lamps not only last longer but also give more brightness and clearness.” Mario Bonilla Ramirez, Coacalco County Under Director of Public Services, also notes that these lamps have resulted in “a diminishing of 25% in the small felonies in the streets.” Per Jim McPhillips, lighting consultant, the success in Mexico City has “resulted in the largest metal halide project in all of Latin America!” And Reforma, the most important daily newspaper in Mexico, identified this municipality as “the best public lighting system in the entire metropolitan area of Mexico City.” Benefits: • 24% more maintained lumens than 250 watt standard probe start metal halide, 85% more than 175 watt standard probe start metal halide • Twice the life of 175 or 250 watt standard probe start systems • 95 lumens per watt and 15,000 hours of life compared with 250W standard probe start metal halide with 74 lumens per watt and 7500 hours of life The Horizontal pulse start details can be found on page 19-20. 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Natural White HIGH CRI AND ® H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Superior Color Rendering Features What could be more natural than sunlight? With HIDirect’s Natural White systems, blues are true blue, reds are more vibrant, whites are whiter, and skin tones appear as they do under sunlight. Natural White lamps, with 5000K color temperature and 90+ CRI, bring daylight indoors! • Superior color rendering; objects appear as they would outdoors • Work spaces look brighter; tasks, such as reading, become easier to perform Benefits • 90% Lumen Maintenance (0.90 Light Loss Factor) • Merchandise and signage are protected from fading with UV Shield® technology - blocks nearly all UV output • The Color of Natural Sunlight: 5000K 90+ Natural White® • High CRI Lighting (Color Rendering Index) • Excellent color uniformity and stability over life of lamp due to formed body arc tube • Designed for open or enclosed luminaires • Shrouded arc tube with ANSI Type-O rating • Operates continuously without weekly shutdowns • Complies with 2005 NEC (National Electrical Code®) UNI-FORM® Systems True Colors 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 15 Natural White Lamps ® HIGH CRI AND H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Natural White® ELECTRONIC Ballasted Open Rated Lamps ANSI Type-O featuring UV Shield® Lamp Description MPSE 250W/BU/UVS/950 Initial Initial Outdoor Indoor Initial Avg. Warm1 Product Nighttime Visual Task2 Photopic Life CCT Up Restrike Oper. Case 3 No. Lumens Lumens Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 95047 22000 21000 17500 20000++ 5000 2-3 5-8 90+ Clear BU±15° A 12 MPSE 290W/BU/UVS/950 95005 28000 26500 22000 20000++ 5000 2-3 5-8 90+ Clear BU±15° B MPSE 320W/BU/ED37/UVS/950 28712 30500 29000 24000 20000++ 5000 2-3 5-8 90+ Clear BU±15° B 6 MPSE 320W/C/BU/ED37/UVS/950 35698 28500 27000 22500 20000++ 5000 2-3 5-8 90+ Coated BU±15° B 6 6 MPSE 350W/BU/UVS/950 62584 33000 31500 26000 20000++ 5000 2-3 5-8 90+ Clear BU±15° B 6 MPSE 350W/C/BU/UVS/950 71035 31500 30000 25000 20000++ 5000 2-3 5-8 90+ Coated BU±15° B 6 MPSE 400W/BU/UVS/950 71564 38500 37000 30500 20000++ 5000 2-3 5-8 90+ Clear BU±15° B 6 MPSE 400W/C/BU/UVS/950 95103 37000 35000 29000 20000++ 5000 2-3 5-8 90+ Coated BU±15° B 6 MPSE 450W/BU/UVS/950 95011 44000 41500 34500 20000++ 5000 2-3 5-8 90+ Clear BU±15° B 6 MPSE 450W/C/BU/UVS/950 95012 41000 39500 32500 20000++ 5000 2-3 5-8 90+ Coated BU±15° B 6 UNI-FORM® Systems MAGNETIC Ballasted Open Rated Lamps ANSI Type-O M181/0 Initial Initial Outdoor Indoor Initial Product Nighttime1 Visual Task2 Photopic No. Lumens Lumens Lumens 24983 84000 80000 66000 Lamp Description MP 775W/BU/BT37/PS/950 Avg. Life CCT Hours4 (K) 20000+ 5000 WarmUp Restrike Oper. Case (Min) (Min) CRI Finish Pos. Fig. Qty 3-5 8-12 90+ Clear BU±15° C 6 Energy Saving RETROFIT Open Rated Lamps ANSI Type-O featuring UV Shield® Fun Facts The center of the sun is about 27 million °F (15 million °C) Initial Initial Outdoor Indoor Photopic Avg. Product ANSI Nighttime1 Visual Task2 Initial Life CCT Operating Case Watts No. Code Lumens Lumens Lumens Hours4 (K) CRI Finish Pos. Fig. Qty Replaces Saved 19523 M153/O 21000 20000 16500 20000+ 5000 90+ Clear BU±15° A 12 250W/BU/ED28/PS 15 Lamp Description MP 250W/BU/UVS/PS/EM/950 MP 320W/BU/ED28/UVS/PS/EM/950 98530 M154/O 28500 27000 22500 20000+ 5000 90+ Clear BU±15° A 12 320W/BU/ED28/PS 20 MP 320W/BU/ED37/UVS/PS/EM/950 98520 M154/O 28500 27000 22500 20000+ 5000 90+ Clear BU±15° B 6 320W/BU/ED37/PS 20 MP 350W/BU/ED28/UVS/PS/EM/950 33149 M131/O 30500 29000 24000 20000+ 5000 90+ Clear BU±15° A 12 350W/BU/ED28/PS 25 MP 350W/BU/UVS/PS/EM/950 51628 M131/O 30500 29000 24000 20000+ 5000 90+ Clear BU±15° B 6 350W/BU/ED37/PS 25 MP 350W/C/BU/UVS/PS/EM/950 38197 M131/O 28500 27000 22500 20000+ 5000 90+Coated BU±15° B 6 350W/C/BU/ED37/PS 25 MP 400W/BU/ED28/UVS/PS/EM/950 72315 M155/O 36000 34500 28500 20000+ 5000 90+ Clear BU±15° A 12 400W/BU/ED28/PS 25 MP 400W/BU/UVS/PS/EM/950 57129 M155/O 36000 34500 28500 20000+ 5000 90+ Clear BU±15° B 6 400W/BU/ED37/PS 25 MP 400W/C/BU/UVS/PS/EM/950 89410 M155/O 34000 32500 27000 20000+ 5000 90+Coated BU±15° B 6 400W/C/BU/ED37/PS 25 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 B C BT37 ED28 A ED37 Notes: All lamps have a light loss factor (LLF) at 8000 hours of 0.9 1 Initial Outdoor Nighttime Lumens = Effective lumens multiplier relative to 4K = 1.27 2 Initial Indoor Visual Task Lumens = Effective lumens multiplier relative to 4K = 1.21 3 A life rating of 20,000++ hours means that at least 80% of the lamps initially installed will still be operating after 20,000 hours. 4 A life rating of 20,000+ hours means that at least 70% of the lamps initially installed will still be operating after 20,000 hours. Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 16 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com ® Natural White Ballasts HIGH CRI AND H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S ELECTRONIC BALLAST Housings 60Hz Ventronic™ Product Number OPE320HF208-277-(X) Voltage 208-277 Input Voltage 188-305 OPE350HF208-277-(X) 208-277 188-305 375 375/(.92*Vline) OPE400HF208-277-(X) 208-277 188-305 430 430/(.92*Vline) 277 249-305 465 465/(.92*Vline) OPE450HF277-(X) Input Watts Maximum Line Current ANSI Code 342 342/(.92*Vline) M154 Fig. A Tot. Wt. (lbs) 15 EMI FCC Part 18 M131 A 15 FCC Part 18 M155 A 15 FCC Part 18 M144 A 15 FCC Part 18 Wattage 250 Input Voltage 277 Product No. V90U8421 ANSI Circuit Input Code Type Watts M153 Reactor 275 Max. Line Current 1.35 UL Total Max. Coil Rise Wiring Dimensions Wt. Capacitor Cap. Cap. Ign. Dist. Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 1.25 3.4 6 13/280 A1 Dry D 5 250 120/208/240/277 V90D8411 M153 CWA 285 2.45/1.45/1.25/1.10 A/A/A/A E 2 250 120/277/347 M153 CWA 288 2.50/1.10/0.90 B/A/B K 2 1.55 3.5 10 15/400 A13 Dry D 2 250 480/120T V90Y8410T M153 CWA 288 0.60 A S1 2 1.55 3.5 10 15/400 A13 Dry D 2 250 480/120T V90Y8411T M153 CWA 288 0.60 A S1 2 2 3.5 10 16/400 320 277 V90U7421 M154 Reactor 349 1.70 A B1 1 1.5 V90J8410 2 3.5 10 16/400 3.6 Dry D 2 Dry D 2 7 16/280 A7 Dry D 2 M154 CWA 365 3.15/1.85/1.60/1.40 A/A/A/A E 2 2 4.1 11.5 22/330 A2 Dry D 2 320 120/208/240/277 V90D7413 M154 CWA 365 3.15/1.85/1.60/1.40 A/A/A/A E 2 2 4.1 11.5 22/330 A2 Dry D 2 320 120/208/240/277 V90D7430 M154 HX-HPF 360 4.80/2.85/2.45/2.10 B/C/C/C Y 2 1.8 3.7 11 20/280 A7 Dry D 2 320 120/277/347 M154 2 1.9 3.75 10.5 22/330 A2 Dry D 2 320 120/277/347 2 1.8 3.9 10.5 20/280 A7 Dry D 2 320 480/120T CWA 368 0.80 A S1 2 2 3.75 10.5 22/330 A2 Dry D 2 320 480/120T V90Y7430T M154 HX-HPF 370 1.20 D W1 2 1.8 3.9 10.5 20/290 A7 Dry D 2 350 277 V90U7521 M131 Reactor 380 1.90 B B1 1 1.8 3.6 7.4 18/280 A7 Dry D 2 CWA 368 3.20/1.40/1.15 B/C/C V90J7430 M154 HX-HPF 365 5.25/2.25/1.70 D/D/D A1 V90Y7412T M154 350 120/208/240/277 V90D7512 M131 350 120/208/240/277 V90D7530 350 120/277/347 350 120/277/347 350 480/120T CWA 400 350 480/120T V90Y7530T 400 277 V90U7621 V90J7512 K CWA 400 3.60/2.10/1.80/1.55 B/C/C/C E 2 1.92 3.8 10.5 24/330 A2 Dry D 2 M131 HX-HPF 395 5.00/2.55/2.50/2.15 B/A/C/C Y 2 1.8 3.7 11 21.5/280 A7 Dry D 2 M131 2 1.92 3.8 10.5 24/330 A2 Dry D 2 CWA 400 3.50/1.55/1.20 B/C/C K V90J7530 M131 HX-HPF 395 5.10/2.15/1.75 C/C/C A1 2 1.8 3.9 10.521.5/290 A7 Dry D 2 V90Y7512T M131 0.90 D S1 2 2.02 3.9 11.2 24/330 A2 Dry D 2 M131 HX-HPF 400 1.35 D W1 2 3.9 10.521.5/290 A7 Dry D 2 M155 Reactor 435 2.10 C B1 1 1.65 3.7 3.9 10.7 26/330 A3 Dry D 2 1.8 M155 CWA 450 4.00/2.30/2.00/1.75 C/C/C/C E 2 400 120/277/347 V90J7612 M155 CWA 451 4.00/1.75/1.40 D/D/D K 2 2.15 400 480/120T V90Y7612T M155 CWA 455 1.00 D S1 2 2.2 4.1 12 26/330 A3 Dry D 2 775 480 V90Y9610T M181 CWA 855 1.85 D S1 3 2.8 4.95 21 22/490 B12 Oil F 10 CWA 845 7.45/4.50/3.75/3.25 B/D/B/C E 3 2.8 4.95 18.5 22/500 B12 Oil F 10 M181 Ballast Options OPE Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 10.1 12.0 9.6 10.0 14.2 7.6 Weight = 15 lbs. Width = 12” Length = 10.1” Height = 14.2” 3.75" (95 mm) 3.30" (84 mm) 4.05" (103mm) A 3 4x6 Core 2 4x4 Core HOLES CLEARED FOR # 10 BOLTS B 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) CWA 4.50" (114mm) HX & CWA REACTOR 1 33/4 x 41/2 Core The Illuminating Engineering Society was formed in 1906 4 11.3 26/330 A3 Dry D 2 Notes for electronic ballast housings are on page 42 A Fun Facts 7 20/280 A7 Dry D 2 400 120/208/240/277 V90D7612 775 120/208/240/277 V90D9610 2 UNI-FORM® Systems 320 120/208/240/277 V90D7412 V90J7411 Natural White® MAGNETIC BALLASTS 60Hz 6.00" (152 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 3.87" (98 mm) 4.375" (111 mm) 5.375"(136 mm) A B A B 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 17 Natural White HIGH CRI AND H I G H C C T U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Natural White Spectrum 100 90 80 70 Relative Power (%) ® 60 50 40 30 Human Eye Sensitivity What Are Scotopic Lumens? The sensitivity of the human eye to different colors of light at various light levels determines the true, or effective, lumen output of a lamp. The eye responds to color depending upon the amount of light available. Nighttime Observations 20 Lumens are the standard measure of light output, but light is actually defined as energy evaluated by the eye. Conventional lumen measurements define the light output response of a person only during high light levels (called photopic light), typical of daylight and interior lighting. The light meter measures photopic light as seen by the central region of the eye. 10 0 393 443 493 543 593 643 693 743 Daylight Spectrum 100 90 80 70 Relative Power (%) 60 50 40 When light levels are very low, like starlight, the viewing conditions are referred to as “scotopic.” Under these conditions, the eye’s visual response changes dramatically. Sensitivity to yellow and red light is greatly reduced, while response to blue light is vastly increased. If lamp lumens under scotopic viewing conditions have been determined using photopic measuring devices, the lumen value does not accurately measure the true amount of light as perceived by the human eye. 30 20 10 0 393 443 493 543 593 643 693 743 Benefits • 90% Lumen Maintenance (0.90 Light Loss Factor) • High CRI Lighting (Color Rendering Index) 90+ • The Color of Natural Sunlight: 5000K Conventionally Measured Outdoor Nighttime Lumens (Photopic Lumens) (Effective Lumens) (S/P) Lumen Maintenance Comparison Daytime Observations Lamps with high scotopic content and high S/P ratios, such as HIDirect’s Natural White® lamps, also improve the ability to see indoors. Human studies have shown that the S/P values, though previously applicable to only nighttime conditions, can be used to describe the “effective lumens” of indoor lighting as well. For example, if two identical objects in 2 different rooms are lighted separately with 4000K and 5000K lamps to equal photopic luminance, the 5000K room will appear 21% brighter (2.1/1.65)0.78. Indoor Visual Task Lumens 1 (Effective Lumens) (S/P) Lumen Maintenance Comparison 40,000 40,000 35,000 35,000 35,000 Natural White® 400W Lamp Lumens 30,000 25,000 20,000 Standard Probe Start 400W 15,000 10,000 20,000 Standard Probe Start 400W Visual Brightness 10,000 5,000 10,000 15,000 20,000 Hours of Operation Ceramic metal halide 4000K; 90 CRI Natural White® 400W 30,000 Natural White® 400W MP 40 25,000 15,000 0.78 Lumen Maintenance Comparison 40,000 30,000 Lamp Lumens UNI-FORM® Systems Wavelength (nm) Lamp Lumens Natural White® Wavelength (nm) Published lumen ratings are based on the “photopic” lumen (“P”), or light measurement based on daytime observations. Lumen measurements, corrected for nighttime vision, are known as “scotopic” lumens (“S”). The ratio of light measured by the 2 methods is called the “S/P ratio”. The S/P ratio for white-blue (5000K daylight) light sources is 2.1. At 4000K the ratio is 1.65, and for HPS lamps the ratio is 0.64. As a result, 4000K light sources are at least twice as effective for viewing at night compared to HPS sources at the same photopic luminance. 5000K light sources are at least three times as effective. 25,000 20,000 Visual Brightness Standard Probe Start 400W 15,000 10,000 5,000 10,000 15,000 20,000 5,000 Hours of Operation Uni-Form Natural White® 5000K; 90+ CRI 10,000 15,000 20,000 Hours of Operation Compact Fluorescent 3500K; 80 CRI 18 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Horizontal Pulse Start U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Performance is Everything For lighting applications, performance is everything. It is important that lighting fixtures provide top performance in terms of heat management, optics and appearance. The lamp and ballast are expected to provide uniform, bright light as well as great lumen maintenance and long life. There are several types of burn positions posted by all manufacturers. First, there is the Universal or “U”. There is the Vertical or “V” and the Base Up or ”BU”. Lastly, we have the Horizontal or “HOR”. Most horizontal lighting applications sacrifice light and life with standard choices in lamps. Benefits Life The walls of the arc tube are substantially thickened with quartz material. This results in less heating of the upper side of the arc tube, which in turn results in longer overall lamp life. Positions of Operation Lumens The Uni-Form arc tube shape has been modified to offer better lumens. The chemistry of the metal halide arc tube has been changed to produce the lumens that equal the typical V or BU versions of the lamp. This also has resulted in greater mean lumens of this product line. HIDirect offers the horizontal pulse start lamp line that now offers long life and high lumens based on a better arc tube. This product line eliminates the problems associated with the POM base lamp and socket and is offered in a variety of jacket sizes and wattages. Universal (U) Any Position Application Targets HIDirect’s horizontal pulse start (H75) series is targeted at the mid-range wattages as well as the enclosed fixture. This series of lamps is perfect for parking garages, car dealerships, site lighting, wall washes, gas station canopies, area lighting and parking lot lighting. 15° 15° UNI-FORM® Systems HIDirect’s Horizontal Pulse Start systems is unique simply because of the Uni-Form® formed body arc tube. Understanding the practical need to remove the POM base and socket requirement from horizontally operating lamps, HIDirect found a way to keep the electrodes at the center of the arc tube at all times, so the install positioning has now become irrelevant. HORIZONTAL OPERATION Horizontal PS Lamps Horizontal +/- 75° (H75) FOR • Longer life compared to both universal and HOR lamps in horizontal operation, and higher lumen output • No POM socket required • Variety of outer jacket shapes and sizes for full cut-off fixtures Features Vertical ±15° (V) • Thicker wall of the lamp arc tube • Better distribution of the halides in the arc stream 75° 75° Horizontal ±75° (H75) Leadership 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 19 Horizontal Pulse Start U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S FOR HORIZONTAL OPERATION Enclosed Rated LAMPS ANSI Type-E Mogul Base Product No. 70764 ANSI Code M136/E Initial Lumens Lumens Per Watt 19000 95 Mean Lumens 15200 Avg. Life Hours 15000 CCT Warm-UpRestrike (K) (Min) (Min) CRI 4000 1-2 2-4 68 Oper. Case Finish Pos. Fig. Qty Clear HOR±75° A 12 250 MS 250W/H75/PS/740 81054 M153/E 22000 88 17600 15000 4000 2-3 3-5 68 Clear HOR±75° D 12 250 MS 250W/H75/T15/PS/740 57625 M153/E 22000 88 17600 15000 4000 2-3 3-5 68 Clear HOR±75° B 12 320 MS 320W/H75/ED28/PS/740 47549 M154/E 30000 94 24000 20000+ 4000 2-3 4-6 68 Clear HOR±75° D 12 320 MS 320W/H75/T15/L/PS/740 79710 M154/E 30000 94 24000 20000+ 4000 2-3 4-6 68 Clear HOR±75° C 12 320 MS 320W/H75/T15/S/PS/740 57626 M154/E 30000 94 24000 20000+ 4000 2-3 4-6 68 Clear HOR±75° B 12 Applications 320 MS 320W/C/H75/ED28/PS/737 12758 M154/E 27000 84 21000 20000+ 3700 2-3 4-6 70 Coated HOR±75° D 12 Indoor or Outdoor 350 MS 350W/C/H75/PS/737 M131/E 31000 89 25000 20000+ 3700 2-3 4-6 70 Coated HOR±75° E 6 • Gas station canopies 350 MS 350W/H75/ED28/PS/740 46959 M131/E 33000 94 26000 20000+ 4000 2-3 4-6 68 Clear HOR±75° D 12 • Parking lots 350 MS 350W/H75/T15/PS/740 93749 M131/E 33000 94 26000 20000+ 4000 2-3 4-6 68 12 • Floodlighting 400 MS 400W/H75/PS/740 58788 M155/E 40000 100 32000 20000+ 4000 2-3 4-6 68 • Site lighting 400 MS 400W/H75/ED28/PS/740 40124 M155/E 40000 100 32000 20000+ 4000 2-3 4-6 68 Clear HOR±75° C Clear HOR±75° E Clear HOR±75° D 12 • Security lighting 400 MS 400W/C/H75/ED28/PS/737 55459 M155/E 38000 95 30000 20000+ 3700 2-3 4-6 70 Coated HOR±75° D 12 • Wall wash 64866 6 Note: 20,000+ hours means that at least 70% of the lamps initially installed will still be operating after 20,000 hours. • Billboard lighting • Indirect lighting A B C D T15 T15 ED28 • Area lighting T15 Dia. = 1 7⁄8” (46mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 1 7⁄8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E39 Dia. = 1 7⁄8” (46mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 E Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 42 20 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com ED37 UNI-FORM® Systems Horizontal PS Lamps Lamp Watts Description 200 MS 200W/H75/T15/PS/740 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Uni-Form Systems ® U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Benefits of Uni-Form Systems • Open-rated lamps (ANSI Type-O) Compared to standard probe start metal halide: - No luminaire lens required, delivers more light • Longer life - up to 50% longer - Operational 24/7 - no shut-off required • Energy savings - more system lumens per watt means more light for less energy - Blocks nearly all damaging ultraviolet light with UV Shield® technology • Improved color uniformity - for minimal color variation from lamp to lamp - Meets 2005 National Electric Code® criteria for open fixtures • Faster warm-up and restrike - one third the time • 70% survival at end of rated life - a 40% improvement over standard probe start metal halide - on electronic ballasts, acheive 80% survival at end of rated life • Pleasant environment and better system performance thanks to quiet, cool-running Opti-Wave® magentic ballasts or Ventronic™ electronic ballasts • Fewer lamp failures and less breakage in shipping because of patented stronger weldless mount Greener Ballasts For more information about this legislation, visit our website. Leadership 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 21 UNI-FORM® Systems HIDirect supports the green energy initiatives of California Title 20 and the Energy Independence & Security Act of 2007, which mandate that metal halide fixtures manufactured in 2009 must contain pulse start ballasts that are at least 88% efficient. We agree with the need to move away from less energy efficient standard probe-start technology and strongly recommend that more efficient and “green” pulse start technology be embraced by all of our customers immediately. Our compliant ballasts have been designated by the green leaf by the product number. 50 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS ANSI Type-O M110/O Medium Base featuring UV Shield® Lamp Description MP 50W/U/UVS/PS Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 32100 3200V/2900H 64V/58H 2100V/1900H 10000V/7500H 4000 1-2 2-4 65 Clear U B 12 MP 50W/C/U/UVS/PS 30041 3000V/2700H 60V/54H 2000V/1800H 10000V/7500H 3700 1-2 2-4 70 Coated U MP 50W/U/UVS/PS/3K 10226 3200V/2900H 64V/58H 2100V/1900H 10000V/7500H 3200 1-2 2-4 65 Clear U B 12 MP 50W/C/U/UVS/PS/3K 10381 3000V/2700H 60V/54H 2000V/1800H 10000V/7500H 3200 1-2 2-4 70 Coated U B 12 B 12 Enclosed Rated LAMPS ANSI Type-E M110/E Medium Base Applications • Landscape Lighting • Downlighting - Low Ceiling • Sconce Lighting Lamp Description MH 50W/U/PS Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 52312 3400V/3100H 68V/62H 2200V/2000H 10000V/7500H 4000 1-2 1-2 65 Clear U A 12 MH 50W/C/U/PS 13093 3200V/2900H 64V/58H 2100V/1900H 10000V/7500H 3700 1-2 1-2 70 Coated U A 12 UNI-FORM® Systems MAGNETIC BALLASTS 60Hz ANSI M110 Input Voltage 120/208/240/277 Product Circuit Input Max. Line UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. No. Type Watts Current Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) V90D5731 HX-HPF 68 1.20/.065/0.60/0.50 A/A/A/A Y 1 1.05 2.45 3.5 6/280 A5 Dry D 2 120/277 V90H5731 HX-HPF 68 1.20/0.50 A/A Q1 1 1.05 2.1 3.5 6/280 A5 Dry D 2 120/277/347 V90J5731 HX-HPF 72 1.20/0.50/0.40 A/A/A A1 1 1.05 2.45 3.3 6/280 A5 Dry D 2 Did you know… Every time you turn on a light switch, 72% of the energy comes from coal. B EDX17 ED17 A Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Narrow Neck Ballast Options HX 1 3x4 Core 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 22 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 70 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O M98/O Shield® Lamp Description MP 70W/U/UVS/PS Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 40389 5300V/4800H 76V/69H 3400V/3100H 15000V/11250H 4000 1-2 2-4 65 Clear U B 12 MP 70W/C/U/UVS/PS 67115 5000V/4500H 71V/64H 3300V/3000H 15000V/11250H 3700 1-2 2-4 70 Coated U MP 70W/U/UVS/PS/3K 45424 5300V/4800H 76V/69H 3400V/3100H 15000V/11250H 3200 1-2 2-4 65 Clear U B 12 MP 70W/C/U/UVS/PS/3K 14611 5000V/4500H 71V/64H 3300V/3000H 15000V/11250H 3200 1-2 2-4 70 Coated U B 12 MP 70W/C/U/ED28/UVS/PS/3K 22466 5000V/4500H 71V/64H 3300V/3000H 15000V/11250H 3200 1-2 2-4 70 Coated U D 12 B 12 Enclosed Rated LAMPS ANSI Type-E M98/E Applications Lamp Description MH 70W/U/PS Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 78138 5600V/5000H 80V/71H 3600V/3300H 15000V/11250H 4000 1-2 1-2 65 Clear U A 12 • Security Lighting • Signage Lighting • Floodlighting MH 70W/C/U/PS 12180 5300V/4800H 76V/69H 3400V/3100H 15000V/11250H 3700 1-2 1-2 70 Coated U A 12 MH 70W/U/ED28/PS 16017 5600V/5000H 80V/71H 3600V/3300H 15000V/11250H 4000 1-2 1-2 65 Clear U C 12 MAGNETIC BALLASTS 60Hz ANSI M98 Product Circuit Input Max. Line UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. No. Type Watts Current Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) V90D5832 HX-HPF 90 1.70/0.95/0.85/0.70 A/A/A/A Y 1 1.45 2.85 4.9 8/280 A5 Dry D 2 120/208/240/277 V90D5833 HX-HPF 88 1.65/0.95/0.80/0.70 A/A/A/A Y 1 1.45 2.85 4.6 8/280 A5 Dry D 2 120/277 V90H5832 HX-HPF 90 A/A Q1 1 1.45 2.85 4.9 8/280 A5 Dry D 2 120/277 V90H5833 HX-HPF 88 1.65/0.70 A/A Q1 1 1.45 2.85 4.6 8/280 A5 Dry D 2 120/277/347 V90J5832 HX-HPF 90 1.70/0.70/0.60 A/A/A A1 1 1.45 2.85 4.9 8/280 A5 Dry D 2 1.70/0.70 UNI-FORM® Systems Input Voltage 120/208/240/277 Fun Facts German inventor Freidrich Winzer (Winsor) was the first person to patent coal gas lighting in 1804. Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Narrow Neck HX 2.44" (62 mm) Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Ballast Options 1 3x4 Core 3.94" (100mm) D ED28 EDX17 C ED28 B ED17 A HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 23 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 100 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Shield® Lamp Description MP 100W/U/UVS/PS Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 96267 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 4000 1-2 3-5 65 Clear U B 12 MP 100W/C/U/UVS/PS 11278 8100V/7300H 81V/73H 5300V/4800H 15000V/11250H 3700 1-2 3-5 70 Coated U MP 100W/U/UVS/PS/3K 96770 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 3200 1-2 3-5 65 Clear U B 12 MP 100W/C/U/UVS/PS/3K 11245 8100V/7300H 81V/73H 5300V/4800H 15000V/11250H 3200 1-2 3-5 70 Coated U B 12 MP 100W/C/U/ED28/UVS/PS/3K 22145 8100V/7300H 81V/73H 5300V/4800H 15000V/11250H 3200 1-2 3-5 70 Coated U D 12 B 12 Applications Enclosed Rated LAMPS ANSI Type-E M90/E • Hazardous Location Lighting • Bollard Lighting • Security Lighting Lamp Description MH 100W/U/PS Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 27266 9000V/8100H 90V/81H 5900V/5300H 15000V/11250H 4000 1-2 2-4 65 Clear U A 12 MH 100W/C/U/PS 15823 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 3700 1-2 2-4 70 Coated U A 12 MH 100W/U/ED28/PS 67868 9000V/8100H 90V/81H 5900V/5300H 15000V/11250H 4000 1-2 2-4 65 Clear U C 12 MH 100W/C/U/ED28/PS 79986 8500V/7700H 85V/77H 5500V/5000H 15000V/11250H 3700 1-2 2-4 70 Coated U C 12 MAGNETIC BALLASTS 60Hz ANSI M90 120/208/240/277 V90D5932 HX-HPF 125 2.60/1.50/1.30/1.15 A/A/A/A Y 2 1.7 3.1 5.3 12/280 A6 Dry D 2 120/277 V90H5932 HX-HPF 125 2.60/1.15 A/A Q1 2 1.7 3.1 5.8 12/280 A6 Dry D 2 120/277/347 V90J5932 HX-HPF 126 2.60/1.15/0.90 A/A/A A1 2 1.7 3.1 5.3 12/280 A6 Dry D 5 B Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Narrow Neck 1 7/8 in Core 2.625" (67mm) D ED28 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Ballast Options 2 3x4 Core HOLES CLEARED FOR # 6 BOLTS 2.188" (56 mm) 1.75" (45 mm) UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 1.65 2.9 2.85 10/280 A6 Dry D 2 C EDX17 ED17 A Max. Line Current 1.05 ED28 Around 70,000 B.C. whole rocks, shells, or other natural found objects were filled with moss or similar material that was soaked in animal fat and then ignited and used as a source of light. Product Circuit Input No. Type Watts V90U5920 Reactor 118 2.189" (56mm) HX Fun Facts Input Voltage 277 REACTOR UNI-FORM® Systems Open Rated LAMPS ANSI Type-O M90/O 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 24 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 125 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O M150/O Avg. Life CCT Warm-Up Restrike Hours (K) (Min) (Min) CRI 15000 4000 1-2 3-5 65 Shield® Lamp Description MP 125W/BU/UVS/PS Product No. 13341 Initial Lumens Mean Lumens Per Watt Lumens 11400 91 8000 Oper. Finish Pos. Clear BU±15° Case Fig. Qty B 12 MP 125W/C/BU/UVS/PS 43319 10800 86 7600 15000 3700 1-2 3-5 70 Coated BU±15° B 12 MP 125W/V/ED28/UVS/PS 25813 11400 91 8000 15000 4000 1-2 3-5 65 Clear D 12 V±15° Enclosed Rated LAMPS ANSI Type-E M150/E Lamp Description MH 125W/HBU/PS Product No. 76602 Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI 12000BU 96BU 8400BU 15000BU 4000 1-2 2-4 65 Oper. Finish Pos. Clear BU±90° Case Fig. Qty A 12 MH 125W/C/HBU/PS 35638 11400BU 91BU 8000BU 15000BU 3700 1-2 2-4 70 Coated BU±90° A 12 MH 125W/HBU/ED28/PS 61914 12000BU 96BU 8400BU 15000BU 4000 1-2 2-4 65 Clear BU±90° C 12 Applications • Parking Garage • Energy Saving Retrofits MAGNETIC BALLASTS 60Hz ANSI M150 Input Voltage 277 Product Circuit Input No. Type Watts V90U8820 Reactor 141 Max. Line Current 0.85 120/208/240/277 V90D8811 CWA 150 1.25/0.75/0.65/0.55 A/A/A/A E 2 1.7 3.15 5.4 12/280 A6 Dry D 2 120/277 V90H8811 CWA 150 1.25/0.55 A/A T1 2 1.7 3.15 5.4 12/280 A6 Dry D 2 120/277/347 V90J8811 CWA 150 1.25/0.55/0.45 A/A/A K 2 1.7 3.15 5.4 12/280 A6 Dry D 2 Think green. Switch to 125W ThinkGreen Replace • Save 60 system watts per luminaire • 96 lumens per watt • Obtain 33% more lumen output at 10,000 hours Standard Probe Start 175 Watt with Uni-Form ® Pulse Start • 50% Longer lamp life 125 Watt • Available in dual and quad tap CWA Lumen Maintenance Comparison C D EDX17 ED28 ED28 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Narrow Neck 2.625" (67mm) 2.188" (56 mm) 1.75" (45 mm) 2.189" (56mm) A B Uni-Form® 125W 320W 12,000 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 8,000 Standard Probe Start 400W 175W (Rated Lamp Life 10,000 Hours) 4,000 5,000 10,000 15,000 Hours of Operation Ballast Options 2 3x4 Core HOLES CLEARED FOR # 6 BOLTS CWA REACTOR 1 7/8 in Core Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Lamp Lumens B ED17 16,000 A 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 25 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com UNI-FORM® Systems HIDirect’s 125W Uni-Form® pulse start metal halide system is the perfect green alternative to the 175W standard probe start. The 125W is a great solution to the California Title 20 and Energy Independence and Security Act of 2007. UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 1.5 2.65 2.5 8/280 A5 Dry D 2 150 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O M102/O Lamp Description MP 150W/U/UVS/PS/740 Applications Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 22455 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 4000 1-2 3-5 68 Clear U B 12 MP 150W/C/U/UVS/PS/737 22888 12600V/11300H 84V/75H 9500V/8500H 15000V/11250H 3700 1-2 3-5 70 Coated U MP 150W/U/UVS/PS/732 22522 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 3200 1-2 3-5 68 Clear U B 12 MP 150W/C/U/UVS/PS/732 80039 12600V/11300H 84V/75H 9500V/8500H 15000V/11250H 3200 1-2 3-5 70 Coated U B 12 B 12 MP 150W/U/ED28/UVS/PS/740 58963 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 4000 1-2 3-5 68 Clear U D 12 MP 150W/C/U/ED28/UVS/PS/737 32147 12600V/11300H 84V/75H 9500V/8500H 15000V/11250H 3700 1-2 3-5 70 Coated U D 12 Enclosed Rated LAMPS ANSI Type-E M102/E Parking Garage Security Lighting Retail Lighting Airport Lighting Residential Roadways Lamp Description MH 150W/U/PS/740 Product Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Case No. Lumens Per Watt Lumens Hours (K) (Min) (Min) CRI Finish Pos. Fig. Qty 99584 14000V/12600H 93V/84H 10500V/9500H 15000V/11250H 4000 1-2 2-4 68 Clear U A 12 MH 150W/C/U/PS/737 94986 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 3700 1-2 2-4 70 Coated U MH 150W/U/ED28/PS/740 13556 14000V/12600H 93V/84H 10500V/9500H 15000V/11250H 4000 1-2 2-4 68 Clear U C 12 MH 150W/C/U/ED28/PS/737 21344 13300V/12000H 89V/80H 10000V/9000H 15000V/11250H 3700 1-2 2-4 70 Coated U C 12 A 12 MAGNETIC BALLASTS 60Hz ANSI M102 Input Voltage 277 Product Circuit Input No. Type Watts V90U7120 Reactor 170 Fun Facts 277 V90U7121 B1 1 2.5 3.9 4.3 14/280 A1 Dry D 2 1875: Henry Woodward patents the electric light bulb. 120/208/240/277 V90D7110 190 1.70/1.00/0.85/0.75 C/C/C/D E 2 2.5 3.9 8.2 16/330 A7 Dry D 2 120/208/240/277 V90D7130 HX-HPF 185 3.60/2.20/1.80/1.55 B/D/C/C Y 2 2.25 3.9 7.1 16/280 A7 Dry D 2 120/277 V90H7130 HX-HPF 185 Q1 2 2.25 3.9 7.1 16/280 A7 Dry D 2 120/277/347 V90J7110 190 1.65/0.70/0.55 D/C/C K 2 2.75 4.1 8.6 16/330 A7 Dry D 2 120/277/347 V90J7130 HX-HPF 185 3.65/1.55/1.25 C/D/D A1 2 2.25 3.9 7.1 16/280 A7 Dry D 2 480/120T V90Y7110T CWA 190 0.40 C S1 2 2.75 4.1 8.6 16/330 A7 Dry D = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 2 Max. Line Current 1.50 Reactor 170 CWA CWA D ED28 ED28 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Narrow Neck Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Ballast Options 2.189" (56mm) A B HX & CWA 2 3x4 Core HOLES CLEARED FOR # 6 BOLTS 2.188" (56 mm) 1.75" (45 mm) B/C C 1 7/8 in Core 2.625" (67mm) A 3.60/1.55 EDX17 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 2.5 3.9 4.3 14/280 A1 Dry D 2 1.50 B ED17 A REACTOR UNI-FORM® Systems • • • • • Shield® 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 26 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 175 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O M152/O Lamp Description MP 175W/BU/UVS/PS/740 Product No. 69854 Initial Lumens Lumens Per Watt 16000 91 Mean Avg. Life Lumens Hours 12800 15000 Shield® CCT Warm-Up Restrike Oper. Case (K) (Min) (Min) CRI Finish Pos. Fig. Qty 4000 1-2 3-5 68 Clear BU±15° C 12 Enclosed Rated LAMPS ANSI Type-E M152/E Lamp Description MS 175W/BU/MED/PS/740 Product No. 16497 Initial Lumens Mean Lumens Per Watt Lumens 17500 100 14000 Avg. Life CCT Warm-Up Restrike Hours (K) (Min) (Min) CRI 15000 4000 1-2 2-4 68 Oper. Finish Pos. Clear BU±15° Case Fig. Qty A 12 MS 175W/C/BU/MED/PS/737 34691 16600 95 13300 15000 3700 1-2 2-4 70 Coated BU±15° A 12 MS 175W/BU/PS/740 68475 17500 100 14000 15000 4000 1-2 2-4 68 Clear BU±15° B 12 MS 175W/C/BU/PS/737 68246 16600 95 13300 15000 3700 1-2 2-4 70 Coated BU±15° B 12 MAGNETIC BALLASTS 60Hz ANSI M152 Input Voltage 277 Product No. V90U7221 120/208/240/277 Circuit Input Type Watts Reactor 194 V90D7210 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 0.85 2.9 4 10/280 A6 Dry D 2 CWA 208 1.90/1.05/0.95/0.80 B/C/A/A E 2 2.63 4 CWA A/A/A/A E 2 3 4.3 8 12.5/330 A1 Dry D 10 120/277/347 V90J7210 CWA 208 1.90/0.80/0.65 B/B/B K 2 2.63 4 8 12.5/330 A1 Dry D 10 480/120T V90Y7210T CWA 208 0.50 C S1 2 2.63 4 8 12.5/330 A1 Dry D 10 A E 2 3 4.3 480/120T V90Y7211T CWA = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 2.188" (56 mm) 1.75" (45 mm) Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Ballast Options 2 3x4 Core HOLES CLEARED FOR # 6 BOLTS 2.189" (56mm) A B HX & CWA REACTOR 1 7/8 in Core 2.625" (67mm) In 1792 William Murdoch began experimenting with gas lighting and probably produced the first gas light in that year. C ED28 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Fun Facts ED28 B ED17 A • Parking Garage • Canopy Lighting • Lowbay Industrial Lighting 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 27 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com UNI-FORM® Systems 120/208/240/277 V90D7211 Max. Line Current 1.05 Applications 200 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O M136/O Lamp Description MP 200W/V/UVS/PS/740 Product No. 22147 Initial Lumens 20000 Lumens Per Watt 100 MP 200W/C/V/UVS/PS/737 59174 19000 MP 200W/C/V/UVS/PS/732 44872 19000 Shield® Mean Avg. Life CCT Warm-Up Restrike Lumens Hours (K) (Min) (Min) CRI 16000 15000 4000 1-2 3-5 68 Oper. Finish Pos. Clear V±15° Case Fig. Qty C 12 95 15200 15000 3700 1-2 3-5 70 Coated V±15° C 12 95 15200 15000 3200 1-2 3-5 70 Coated V±15° C 12 Enclosed Rated LAMPS ANSI Type-E M136/E Applications Energy Saving Retrofits Parking Garage Roadways Site Lighting Product No. 60811 Initial Lumens Mean Lumens Per Watt Lumens 21000 105 16800 Avg. Life CCT Warm-Up Restrike Hours (K) (Min) (Min) CRI 12000 4000 1-2 2-4 68 Oper. Finish Pos. Clear BU±15° Case Fig. Qty A 12 MS 200W/C/BU/MED/PS/737 60812 20000 100 16000 12000 3700 1-2 2-4 70 Coated BU±15° A MS 200W/V/PS/740 57739 21000 105 16800 15000 4000 1-2 2-4 68 Clear V±15° B 12 MS 200W/C/V/PS/737 70345 20000 100 16000 15000 3700 1-2 2-4 70 Coated V±15° B 12 MS 200W/H75/T15/PS/740 70764 19000 95 15200 15000 4000 1-2 2-4 68 Clear HOR±75° D 12 12 Benefits MAGNETIC BALLASTS 60Hz ANSI M136 • 21,000 lumens! Input Voltage 277 Product No. V90U7321 120/208/240/277 V90D7330 HX-HPF 235 3.30/2.05/1.65/1.45 A/A/A/A Y 2 2.25 3.9 7 16/290 A7 Dry D 2 • Highest wattage available in an ED17 jacket 120/208/240/277 V90D7310 CWA 232 2.00/1.15/1.00/0.85 A/A/A/A E 2 2.5 3.9 8 16/300 A7 Dry D 2 120/208/240/277 V90D7311 CWA 228 1.95/1.15/1.00/0.85 A/A/A/A E 3 2 3.8 7.5 15/300 2 More light in a smaller lamp offers designers better, more cost-effective and energyefficient choices: 120/208/240/277 V90D7312 CWA A/A/A/A E 2 3 4.3 1. Achieve the same light levels using fewer fixtures Max. Line Current 1.25 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 1 2.9 4.5 12/280 A6 Dry D 5 D 120/277/347 V90J7330 HX-HPF 240 3.45/1.45/1.15 D/C/C A1 2 2.45 3.9 7.5 16/290 A7 Dry D 2 120/277/347 V90J7310 2.00/0.85/0.70 A/A/A K 2 2.5 3.9 8 16/300 A7 Dry D 2 480/120T V90Y7330T HX-HPF 235 0.80 D W1 2 2.45 3.9 8 16/280 A7 Dry D 2 480/120T V90Y7310T 0.50 A F 2 2.5 3.9 8 16/300 A7 Dry D 2 8 15/300 CWA CWA 235 235 480/120T V90Y7311T CWA A F 3 2 3.8 480/120T V90Y7312T CWA A F 2 3 4.3 = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 B C Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 1 33/4 x 41/2 Core 4.50" (114mm) 4.05" (103mm) A Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Dia. = 1 7/8” (46mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Ballast Options 2 3x4 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) D T15 ED28 ED17 A ED28 OR 2. Achieve increased light levels using the same number of fixtures Circuit Input Type Watts Reactor 219 B HX & CWA • 50% longer life than 250W and 175W standard probe start systems REACTOR UNI-FORM® Systems • • • • Lamp Description MS 200W/BU/MED/PS/740 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 28 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 250 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O M153/O Lamp Description MP 250W/BU/UVS/PS/740 Product No. 64658 Initial Lumens Mean Lumens Per Watt Lumens 23800 95 19000 MP 250W/C/BU/UVS/PS/737 32658 22600 90 18000 Avg. Life CCT Warm-Up Restrike Hours (K) (Min) (Min) CRI 15000 4000 2-3 4-6 68 15000 3700 2-3 4-6 70 Shield® Oper. Finish Pos. Clear BU±15° Coated BU±15° Case Fig. Qty B 12 B 12 Enclosed Rated LAMPS ANSI Type-E M153/E Lamp Description MS 250W/V/PS/740 Product No. 49621 Initial Lumens Mean Lumens Per Watt Lumens 25000 100 20000 Avg. Life CCT Warm-Up Restrike Hours (K) (Min) (Min) CRI 15000 4000 2-3 3-5 68 MS 250W/C/V/PS/737 81365 23800 95 19000 15000 3700 2-3 3-5 70 Coated V±15° A 12 MS 250W/H75/PS/740 81054 22000 88 17600 15000 4000 2-3 3-5 68 Clear HOR±75° A 12 MS 250W/H75/T15/PS/740 57625 22000 88 17600 15000 4000 2-3 3-5 68 Clear HOR±75° C 12 Finish Clear Oper. Pos. V±15° Case Fig. Qty A 12 Applications • Site Lighting • Lowbay Industrial Lighting MAGNETIC BALLASTS 60Hz ANSI M153 Product No. V90U8421 120/208/240/277 Circuit Input Type Watts Reactor 275 Max. Line Current 1.35 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 1 1.25 3.4 6 13/280 A1 Dry D 5 V90D8410 CWA 288 2.50/1.45/1.25/1.10 B/B/A/A E 2 1.55 3.5 10 15/400 A13 Dry D 2 120/208/240/277 V90D8411 CWA 285 2.45/1.45/1.25/1.10 A/A/A/A E 2 2 3.5 10 16/400 Dry D 2 120/277/347 V90J8410 CWA 288 2.50/1.10/0.90 B/A/B K 2 1.55 3.5 10 15/400 A13 Dry D 2 480/120T V90Y8410T CWA 288 0.60 A S1 2 1.55 3.5 10 15/400 A13 Dry D 2 CWA 288 0.60 A S1 2 2 3.5 10 16/400 2 480/120T V90Y8411T Dry D = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 B HX & CWA REACTOR 4.05" (103mm) A Dia. = 1 7/8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E39 2 4x4 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) T15 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 1 33/4 x 41/2 Core 4.50" (114mm) In 1879 Thomas Edison and Joseph Wilson Swan patented the carbon-thread incandescent lamp and in 1880 Edison produced a 16 watt lightbulb that lasted 1500 hours. C ED28 B ED28 A Fun Facts 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 29 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com UNI-FORM® Systems Input Voltage 277 320 Watt Lamps U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield® Lamp Product Description No. MP 320W/V/ED37/EL/UVS/PS/740 25984 Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Lumens Per Watt Lumens Hours** (K) (Min) (Min) CRI 31000 97 26000 20000++ 4000 2-3 5-8 68 Finish Clear MP 320W/C/V/ED37/EL/UVS/PS/73732409 29000 Coated V±15° 91 25000 20000++ 3700 2-3 5-8 70 Oper. Pos. V±15° featuring UV Open Rated LAMPS ANSI Type-O M154/O Mogul Base Case Fig. Qty C 6 C 6 Shield® Lamp Product Description No. MP 320W/BU/ED28/UVS/PS/740 10103 Initial Lumens Mean Lumens Per Watt Lumens 31000 97 25000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 5-8 68 Oper. Finish Pos. Clear BU±15° Applications MP 320W/C/BU/ED28/UVS/PS/737 10104 29000 91 23000 20000+ 3700 2-3 5-8 70 Coated BU±15° B • • • • MP 320W/BU/ED37/UVS/PS/740 21714 31000 97 25000 20000+ 4000 2-3 5-8 68 Clear BU±15° D 6 MP 320W/C/BU/ED37/UVS/PS/737 32795 29000 91 23000 20000+ 3700 2-3 5-8 70 Coated BU±15° D 6 MP 320W/C/BU/ED37/UVS/PS/732 66506 29000 91 23000 20000+ 3200 2-3 5-8 70 Coated BU±15° D 6 Big Box Retail Warehouse Lighting Residential Roadways Site Lighting Case Fig. Qty B 12 12 Benefits • 33,000 Initial Lumens Lamp Description MS 320W/V/ED28/PS/740 Product No. 59194 Initial Lumens Mean Lumens Per Watt Lumens 33000 103 26000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 4-6 68 Finish Clear Oper. Pos. V±15° Case Fig. Qty A 12 MS 320W/C/V/ED28/PS/737 77594 31000 97 25000 20000+ 3700 2-3 4-6 70 Coated V±15° A 12 • 26,000 Mean Lumens MS 320W/V/ED37/PS/740 52236 33000 103 26000 20000+ 4000 2-3 4-6 68 Clear C 6 Compared to 400W standard probe start system: MS 320W/C/V/ED37/PS/737 67712 31000 97 25000 20000+ 3700 2-3 4-6 70 Coated V±15° C 6 MS 320W/H75/ED28/PS/740 47549 30000 94 24000 20000+ 4000 2-3 4-6 68 Clear HOR±75° A 12 • Save up to 106 system watts per luminaire MS 320W/C/H75/ED28/PS/737 12758 27000 84 21000 20000+ 3700 2-3 4-6 70 Coated HOR±75° A 12 MS 320W/H75/T15/L/PS/740 79710 30000 94 24000 20000+ 4000 2-3 4-6 68 Clear HOR±75° E 12 MS 320W/H75/T15/S/PS/740 57626 30000 94 24000 20000+ 4000 2-3 4-6 68 Clear HOR±75° F 12 • Achieve 13% more lumen output at 8,000 hours and almost 30% more lumen output at 20,000 hours Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours. **A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours. • More Reliable: At end of rated life 70% of the lamps initially installed will be operating; 80% survival on electronic ballasts Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 ED37 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 F T15 E D ED37 C ED28 B ED28 A T15 UNI-FORM® Systems Enclosed Rated LAMPS ANSI Type-E M154/E Mogul Base Dia. = 1 7⁄8” (46mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Dia. = 1 7/8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E39 30 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com V±15° 320 Watt Ballasts U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S ELECTRONIC BALLAST Housings 60Hz Ventronic™ Product Number OPE320HF208-277-(X) Voltage 208-277 Input Voltage 188-305 Input Watts Maximum Line Current ANSI Code 342 342/(.92*Vline) M154 Fig. 1 Tot. Wt. (lbs) 15 EMI FCC Part 18 MAGNETIC BALLASTS 60Hz ANSI M132/M154 Input Voltage 277 Product No. V90U7421 120/208/240/277 V90D7411 Circuit Input Type Watts Reactor 349 Max. Line Current 1.70 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) A B1 2 1.5 3.6 7 16/280 A7 Dry D 2 CWA 368 3.20/1.80/1.60/1.40 B/B/B/B E 3 1.85 3.65 22/330 A2 Dry D 2 120/208/240/277 V90D7412 CWA 365 3.15/1.85/1.60/1.40 A/A/A/A E 3 2 4.1 11.5 22/330 A2 Dry D 2 120/208/240/277 V90D7413 CWA 365 3.15/1.85/1.60/1.40 A/A/A/A E 3 2 4.1 11.5 22/330 A2 Dry D 2 HX-HPF 360 4.80/2.85/2.45/2.10 B/C/C/C Y 3 1.8 3.7 20/280 A7 Dry D 2 3 1.9 3.75 10.5 22/330 A2 Dry D 2 120/208/240/277 V90D7430 120/277/347 V90J7411 120/277/347 V90J7430 480/120T V90Y7411T 480/120T V90Y7412T 480/120T V90Y7430T CWA 10 11 368 3.20/1.40/1.15 B/C/C K HX-HPF 365 5.25/2.25/1.70 D/D/D A1 3 1.8 3.9 10.5 20/280 A7 Dry D 2 0.80 D S1 3 1.9 3.75 10.5 22/330 A2 Dry D 2 3.75 10.5 22/330 A2 Dry D 2 3.9 2 CWA 368 CWA 368 0.80 A S1 3 2 HX-HPF 370 1.20 D W1 3 1.8 10.5 20/290 A7 Dry D Applications • Energy Saving Retrofits • Security Lighting • Parking Garage ThinkChoices HIDirect has the largest selection of systems to replace standard probe start 400 Watt systems HIDirect’s 320W Uni-Form® pulse start metal halide system is the perfect green alternative to the 400W standard probe start system. HIDirect has the largest offering of 320W pulse start systems, open or enclosed fixture rated. Lumen Maintenance Comparison 45,000 OPE 1 40,000 10.1 Lamp Lumens 12.0 35,000 30,000 9.6 10.0 Uni-Form® 320W 14.2 7.6 25,000 Weight = 15 lbs. Width = 12” Length = 10.1” Height = 14.2” 20,000 Standard Probe Start 400W 15,000 5,000 10,000 15,000 20,000 Hours of Operation 4.50" (114mm) 3 4x4 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) 4.05" (103mm) A B HX & CWA REACTOR 2 33/4 x 41/2 Core 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 31 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com UNI-FORM® Systems = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 350 Watt Lamps U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield® Lamp Description MP 350W/V/EL/UVS/PS/740 Product No. 44983 Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Lumens Per Watt Lumens Hours** (K) (Min) (Min) CRI 35000 100 30000 20000++ 4000 2-3 5-8 68 Finish Clear MP 350W/C/V/EL/UVS/PS/737 48952 33000 Coated V±15° 94 28000 20000++ 3700 2-3 5-8 70 Open Rated LAMPS ANSI Type-O M131/O Mogul Base Applications Big Box Retail Warehouse Lighting Residential Roadways Site Lighting Energy Saving Retrofits UNI-FORM® Systems • • • • • Oper. Pos. V±15° Case Fig. Qty D 6 D 6 featuring UV Shield® Oper. Pos. V±15° Case Fig. Qty D 6 Lamp Description MP 350W/V/UVS/PS/740 Product No. 22149 Initial Lumens Mean Lumens Per Watt Lumens 35000 100 28000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 5-8 68 Finish Clear MP 350W/C/V/UVS/PS/737 44097 33000 94 26000 20000+ 3700 2-3 5-8 70 Coated V±15° D MP 350W/C/V/UVS/PS/732 27845 33000 94 26000 20000+ 3200 2-3 5-8 70 Coated V±15° D 6 MP 350W/V/ED28/UVS/PS/740 47887 35000 100 28000 20000+ 4000 2-3 5-8 68 Clear V±15° B 12 MP 350W/C/V/ED28/UVS/PS/737 55401 33000 94 26000 20000+ 3700 2-3 5-8 70 Coated V±15° B 12 6 Enclosed Rated LAMPS ANSI Type-E M131/E Mogul Base Lamp Description MS 350W/V/PS/740 Product No. 98389 Initial Lumens Mean Lumens Per Watt Lumens 37000 106 29000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 4-6 68 Finish Clear Oper. Pos. V±15° MS 350W/C/V/PS/737 71329 35000 100 28000 20000+ 3700 2-3 4-6 70 Coated V±15° C 6 MS 350W/V/ED28/PS/740 52980 37000 106 29000 20000+ 4000 2-3 4-6 68 Clear A 12 MS 350W/C/H75/PS/737 64866 31000 89 25000 20000+ 3700 2-3 4-6 70 Coated HOR±75° C 6 V±15° Case Fig. Qty C 6 MS 350W/H75/ED28/PS/740 46959 33000 94 26000 20000+ 4000 2-3 4-6 68 Clear HOR±75° A 12 MS 350W/H75/T15/PS/740 93749 33000 94 26000 20000+ 4000 2-3 4-6 68 Clear HOR±75° E 12 Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours. **A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours. Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 32 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com T15 E ED37 D ED37 C ED28 B ED28 A Dia. = 1 7⁄8” (46mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 350 Watt Ballasts U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S ELECTRONIC BALLAST Housings 60Hz Ventronic™ Product Number OPE350HF208-277-(X) Voltage 208-277 Input Voltage 188-305 Input Watts Maximum Line Current ANSI Code 375 375/(.92*Vline) M131 Fig. 1 Tot. Wt. (lbs) 15 EMI FCC Part 18 MAGNETIC BALLASTS 60Hz ANSI M131 Input Voltage 277 Product No. V90U7521 120/208/240/277 V90D7512 120/208/240/277 V90D7530 120/277/347 V90J7512 120/277/347 V90J7530 480/120T V90Y7512T 480/120T V90Y7530T Circuit Input Type Watts Reactor 380 CWA Max. Line Current 1.90 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) B B1 2 1.8 3.6 7.4 18/280 A7 Dry D 2 400 3.60/2.10/1.80/1.55 B/C/C/C HX-HPF 395 5.00/2.55/2.50/2.15 B/A/C/C E 3 1.92 3.8 10.5 24/330 A2 Dry D 2 Y 3 1.8 3.7 11 21.5/280 A7 Dry D 2 400 3.50/1.55/1.20 B/C/C K 3 1.92 3.8 10.5 24/330 A2 Dry D 2 HX-HPF 395 5.10/2.15/1.75 C/C/C A1 3 1.8 3.9 10.5 21.5/290 A7 Dry D 2 400 0.90 D S1 3 2.02 3.9 11.2 24/330 A2 Dry D 2 HX-HPF 400 1.35 D W1 3 1.8 3.9 10.5 21.5/290 A7 Dry D 2 CWA CWA = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 Applications • • • • • Big Box Retail Warehouse Lighting Residential Roadways Site Lighting Energy Saving Retrofits UNI-FORM® Systems OPE 1 10.1 12.0 9.6 10.0 14.2 7.6 Weight = 15 lbs. Width = 12” Length = 10.1” Height = 14.2” 4.50" (114mm) 3 4x4 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) 4.05" (103mm) A B HX & CWA REACTOR 2 33/4 x 41/2 Core 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 33 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 400 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield® Lamp Description MP 400W/V/EL/UVS/PS/740 Product No. 56745 Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Lumens Per Watt Lumens Hours*** (K) (Min) (Min) CRI 41000 103 35000 20000++ 4000 2-3 5-8 68 Finish Clear MP 400W/C/V/EL/UVS/PS/737 78752 39000 Coated V±15° 98 33000 20000++ 3700 2-3 5-8 70 Oper. Pos. V±15° Case Fig. Qty D 6 D 6 Open Rated LAMPS ANSI Type-O M155/O Mogul Base featuring UV Shield® Applications Highbay Industrial Manufacturing Lighting Site Lighting Big Box Retail Convention Centers UNI-FORM® Systems • • • • • Lamp Description MP 400W/V/UVS/PS/740 Product No. 71642 Initial Lumens Mean Lumens Per Watt Lumens 41000 103 33000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 5-8 68 MP 400W/C/V/UVS/PS/737 45541 39000 98 31000 20000+ 3700 2-3 5-8 70 MP 400W/V/ED28/UVS/PS/740 12445 41000 103 33000 20000+ 4000 2-3 5-8 68 Oper. Pos. V±15° Coated V±15° Clear V±15° MP 400W/C/V/ED28/UVS/PS/737 88648 39000 98 31000 20000+ 3700 2-3 5-8 70 Coated V±15° Finish Clear Case Fig. Qty D 6 D 6 B 12 B 12 Enclosed Rated LAMPS ANSI Type-E M155/E Mogul Base Lamp Description MS 400W/V/PS/740 Product No. 73531 MS 400W/C/V/PS/737 42401 MS 400W/V/ED28/PS/740 85260 Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Oper. Lumens Per Watt Lumens Hours* (K) (Min) (Min) CRI Finish Pos. 44000 110 3500020000+/30000**4000 2-3 4-6 68 Clear V±15° 42000 105 3300020000+/30000**3700 2-3 4-6 70 Coated V±15° 44000 110 35000 20000+ 4000 2-3 4-6 68 Clear V±15° MS 400W/C/V/ED28/PS/737 46416 42000 105 33000 20000+ 3700 2-3 4-6 70 MS 400W/H75/PS/740 58788 40000 100 32000 20000+ 4000 2-3 4-6 68 MS 400W/H75/ED28/PS/740 40124 40000 100 32000 20000+ 4000 2-3 4-6 68 MS 400W/C/H75/ED28/PS/737 55459 38000 95 30000 20000+ 3700 2-3 4-6 70 Case Fig. Qty C 6 C 6 A 12 Coated V±15° Clear HOR±75° A 12 C 6 Clear HOR±75° Coated HOR±75° A 12 A 12 Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours. **At 120 or more hours per start, lamp life is rated at 30,000 hours ***A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours. ELECTRONIC BALLAST Housings 60Hz Ventronic™ Product Number OPE400HF208-277-(X) Voltage 208-277 Input Voltage 188-305 Input Watts Maximum Line Current ANSI Code 430 430/(.92*Vline) M155 Fig. 1 Tot. Wt. (lbs) 15 EMI FCC Part 18 MAGNETIC BALLASTS 60Hz ANSI M135/M155 Input Voltage 277 Product No. V90U7621 Circuit Input Type Watts Reactor 435 Max. Line Current 2.10 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) C B1 2 1.65 3.7 7 20/280 A7 Dry D 2 120/208/240/277 V90D7612 CWA 450 4.00/2.30/2.00/1.75 C/C/C/C E 3 2 3.9 10.7 26/330 A3 Dry D 120/277/347 V90J7612 CWA 451 4.00/1.75/1.40 D/D/D K 3 2.15 4 11.3 26/330 A3 Dry D 480/120T V90Y7612T CWA 455 1.00 D S1 3 2.2 4.1 12 26/330 A3 Dry D 2 2 2 = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 OPE 10.1 12.0 REACTOR 2 33/4 x 41/2 Core 1 4.50" (114mm) 10.0 14.2 Weight = 15 lbs. Width = 12” Length = 10.1” Height = 14.2” 4.05" (103mm) A Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 3 4x4 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) 9.6 7.6 34 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 B HX & CWA ED28 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Ballast Options D ED37 C ED37 B ED28 A 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B 450 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS for Operation on Electronic Ballasts ANSI Type-O M___/O Mogul Base featuring UV Shield® Lamp Description MP 450W/BU/EL/UVS/PS/740 Product No. 30285 Initial Lumens Mean Avg. Life CCT Warm-Up Restrike Lumens Per Watt Lumens Hours** (K) (Min) (Min) CRI 47000 104 40000 20000++ 4000 2-3 5-8 68 Oper. Finish Pos. Clear BU±15° MP 450W/C/BU/EL/UVS/PS/737 24908 45000 Coated BU±15° 100 39000 20000++ 3700 2-3 5-8 70 featuring UV Open Rated LAMPS ANSI Type-O M144/O Mogul Base Lamp Description MP 450W/BU/UVS/PS/740 Product No. 65072 Initial Lumens Mean Lumens Per Watt Lumens 47000 104 37000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 5-8 68 Oper. Finish Pos. Clear BU±15° MP 450W/C/BU/UVS/PS/737 59216 45000 20000+ 3700 Coated BU±15° 100 36000 2-3 5-8 70 Case Fig. Qty B 6 B 6 Shield® Case Fig. Qty B 6 B 6 Enclosed Rated LAMPS ANSI Type-E M144/E Mogul Base Lamp Description MS 450W/V/PS/740 Product No. 10079 Initial Lumens Mean Lumens Per Watt Lumens 50000 111 40000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 2-3 4-6 68 Finish Clear MS 450W/C/V/PS/737 10138 47000 20000+ 3700 Coated V±15° 104 37000 2-3 4-6 70 Oper. Pos. V±15° Applications • Highbay Industrial • Manufacturing Lighting Case Fig. Qty A 6 A 6 Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours. **A life rating of 20,000++ hours means that 80% of the lamps initially installed will still be operating after 20,000 hours. UNI-FORM® Systems ELECTRONIC BALLAST Housings 60Hz Ventronic™ Product Number OPE450HF277-(X) Voltage 277 Input Voltage 249-305 Input Watts Maximum Line Current ANSI Code 465 465/(.92*Vline) M144 Fig. 1 Tot. Wt. (lbs) 15 EMI FCC Part 18 MAGNETIC BALLASTS 60Hz ANSI M144 Input Voltage 277 Product No. V90U8521 Circuit Input Type Watts Reactor 485 120/208/240/277 V90D8512 CWA 120/208/240/277 V90D8530 120/277/347 V90J8511 120/277/347 V90J8530 480/120T V90Y8512T 480/120T V90Y8530T Max. Line Current 2.30 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) C B1 2 1.8 3.75 8.1 22/280 A2 Dry D 2 506 4.40/2.50/2.20/1.90 C/D/D/D E 3 2.3 4.2 HX-HPF 505 7.00/3.60/3.50/3.00 B/A/D/D Y 3 2.4 4.5 CWA 12.4 32/300 A10 Dry D 14 2 30/280 A7 Dry D 2 2 507 4.40/1.90/1.50 D/D/D K 3 2.3 4.2 12.4 32/300 A10 Dry D HX-HPF 510 6.25/2.55/2.20 D/B/D A1 3 2.6 4.5 14.5 30/280 A7 Dry D 2 515 1.10 D S1 3 2.3 4.2 12.5 32/300 A10 Dry D 2 HX-HPF 515 1.75 D W1 3 2.6 4.5 CWA 14 30/280 A7 Dry D 2 = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 Ballast Options B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 ED37 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 OPE 10.1 12.0 REACTOR 2 33/4 x 41/2 Core 1 4.50" (114mm) 3.75" (95 mm) 3.30" (84 mm) 9.6 10.0 14.2 7.6 Weight = 15 lbs. Width = 12” Length = 10.1” Height = 14.2” 3 4x4 Core HOLES CLEARED FOR # 10 BOLTS 4.05" (103mm) A B HX & CWA ED37 A 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B 35 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 575 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS ANSI Type-O M178/O EX39 Mogul Base Lamp Description MP 575W/BU/BT37/PS/740 Product No. 60023 Initial Lumens Mean Lumens Per Watt Lumens 60000 104 48000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 3-5 8-12 68 Oper. Finish Pos. Clear BU±15° MP 575W/C/BU/BT37/PS/737 60020 57000 20000+ 3700 Coated BU±15° 99 45000 3-5 8-12 70 Case Fig. Qty A 6 A 6 MAGNETIC BALLASTS 60Hz ANSI M178 Applications • Site Lighting • Highbay Industrial Input Voltage 277 Product Circuit Input No. Type Watts V90U5521 Reactor 620 Max. Line Current 3.30 480 V90Y5530T HX-HPF 645 2.30 W1 2 3.25 5 120/208/240/277 V90D5530 HX-HPF 635 8.75/4.70/4.45/3.80 B/A/C/C Y 2 3.25 5 18 38/330 A14 Dry D 2 120/277/347 V90J5530 HX-HPF 635 A1 2 3.25 5 18 38/330 A14 Dry D 2 9.75/3.70/3.20 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) D B1 1 2.05 3.85 8 30/280 A2 Dry D 2 D D/C/D 18.5 38/330 A14 Dry D 2 Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours. Benefits • Twice the mean lumens of a 400W standard probe start metal halide lamp • 60,000 initial lumens • Long life: 20,000+ hours • Brightest lamp in its class 575 Watt Pulse Start 400 Watt Standard Probe Start 36 Number of Fixtures: 72 Illuminance: 31 fc 111,600 kWh BT37 vs 32 fc .80 A Light Loss Factor: Energy Consumption: .65 163,800 kWh $ 4,176/year Savings 0 % 30 Energy Savings 0 Note: based on 5000 hours/year operation at $.08/kWh Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 4.50" (114mm) 2 4x4 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) 4.05" (103mm) A B HX & CWA 1 33/4 x 41/2 Core REACTOR UNI-FORM® Systems Highbay Lighting Layout Comparison 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 36 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 875 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Open Rated LAMPS ANSI Type-O M166/O Lamp Description MP 875W/BU/BT37/PS/740 Product No. 58953 Initial Lumens Mean Lumens Per Watt Lumens 95000 109 76000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 3-5 8-12 68 Oper. Finish Pos. Clear BU±15° MP 875W/C/BU/BT37/PS/737 41686 90000 20000+ 3700 70 Coated BU±15° 103 72000 3-5 8-12 Case Fig. Qty C 6 C 6 Enclosed Rated LAMPS ANSI Type-E M166/E Lamp Description MS 875W/BU/BT37/PS/740 Product No. 22619 Initial Lumens Mean Lumens Per Watt Lumens 100000 114 80000 Avg. Life CCT Warm-Up Restrike Hours* (K) (Min) (Min) CRI 20000+ 4000 3-5 8-12 68 Oper. Finish Pos. Clear BU±15° MS 875W/BD/BT37/PS/740 35426 100000 114 80000 20000+ 4000 3-5 8-12 68 Clear BD±15° A 6 Applications MS 875W/HOR/BT37/PS/740** 33759 95000 109 76000 12000 3-5 8-12 68 Clear HOR±45° B 6 • Retail Auto Lots 4000 Case Fig. Qty A 6 Notes: *A life rating of 20,000+ hours means that 70% of the lamps initially installed will still be operating after 20,000 hours. **Permitted rotation about horizontal lamp axis ±15Ëš. • Highbay Industrial Lighting MAGNETIC BALLASTS 60Hz ANSI M166 • Indoor Sports/Recreation Max. Line Current 2.75 • Aircraft Hangers Product Circuit Input No. Type Watts V90Y8620 Reactor 925 UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) C B1 1 3.3 5.2 13.5 15/480 B9 Oil F 5 120/208/240/277 V90D8611 CWA 940 8.00/4.50/4.00/3.45 B/A/A/A E 2 2.8 4.8 22/460 B12 Oil F 10 120/208/240/277 V90D8612 CWA 940 7.85/4.85/4.05/3.45 B/C/B/B E 2 2.8 4.95 18.5 22/470 B12 Oil F 10 21 120/277/347 V90J8611 CWA 940 8.00/3.45/2.75 A/A/A K 2 2.93 4.95 22 22/460 B12 Oil F 5 480 V90Y8611T CWA 945 2.00 C S1 2 2.82 4.85 21 22/460 B12 Oil F 2 480 V90Y8612T CWA 950 2.00 C S1 2 2.8 4.9 18.5 22/470 B12 Oil F 10 Benefits • A great replacement for a 1000 watt standard probe start metal halide system! • Save up to 155 watts per luminaire • High lumen output: 100,000 lumens -115 lamp lumens per watt A B C BT37 BT37 BT37 • Long life: 20,000+ hours Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) 4.50" (114mm) 2 4x6 Core HOLES CLEARED FOR # 10 BOLTS 3.75" (95 mm) 3.30" (84 mm) 4.05" (103mm) A B CWA REACTOR 1 33/4 x 41/2 Core Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 6.00" (152 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 3.87" (98 mm) 4.375" (111 mm) 5.375"(136 mm) A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 37 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com UNI-FORM® Systems Input Voltage 480 1000 Watt U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Enclosed Rated LAMPS ANSI Type-E M141/E Mogul Base Lamp Description MS 1000W/BU/BT37/PS/740 Product No. 71722 Initial Lumens Mean Lumens Per Watt Lumens 115000 115 86000 MS 1000W/HOR/T25/PS/734* 49111 110000 110 Avg. Life CCT Warm-Up Restrike Hours (K) (Min) (Min) CRI 12000 4000 3-5 8-12 68 77000 5000 3400 3-5 10-15 68 Oper. Finish Pos. Clear BU±15° Clear HOR±45° Case Fig. Qty A 6 B 6 Notes: * Permitted rotation about horizontal lamp axis ±15Ëš MAGNETIC BALLASTS 60Hz ANSI M141 Applications Product No. V90D7810 Circuit Input Max. Line UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign. Max.Dist. Type Watts Current Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig. (ft) CWA 1080 9.00/5.20/4.50/3.90 D/A/B/B E 1 2.8 4.8 21 24/480 B12 Oil F 10 120/208/240/277 V90D7811 CWA 1080 8.95/5.55/4.55/3.95 D/D/C/D E 1 2.8 4.95 18.5 24/480 B12 Oil F 10 120/277/347 V90J7810 CWA 1080 9.00/3.90/3.15 D/B/A K 1 2.93 4.95 21.5 24/480 B12 Oil F 10 480/120T V90Y7810T CWA 1080 2.25 D S1 1 2.82 4.85 21 24/480 B12 Oil F 10 480/120T V90Y7811T CWA 1085 2.35 E S1 1 2.8 4.85 21 24/480 B12 Oil F 10 Fun Facts A B BT37 T25 The United States consumes 25% of all the world’s energy Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Dia. = 3 1/8” (79mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) 1 4x6 Core CWA UNI-FORM® Systems • Energy Saving Retrofits • Highbay Industrial • Site Lighting Input Voltage 120/208/240/277 6.00" (152 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 3.87" (98 mm) 4.375" (111 mm) 5.375"(136 mm) A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 38 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Go Green: Retrofit and Save! U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Other Energy Saving Options HIDirect has the widest selection and variety of energy saving pulse start Old Standard HIDirect’s Energy metal halide Probe Start Saving Uni-Form® lighting systems. Wattage Pulse Start Solution Achieve equal or 1000W 875W more light while 775W Natural White® using less energy 575W compared to 400W 450Wwith fewer fixtures older standard 350W probe start metal 320W halide wattages. 250W 200W With so many 175W options available, 175W 150W HIDirect has the 125W perfect energy 100W saving solution for all your lighting needs. Before Replace standard probe start 1000 Watt with 875 Watt Lamp Lumens 100,000 After Uni-Form® 875W 80,000 60,000 40,000 Standard Probe Start 1000W 12,000 10,000 15,000 UNI-FORM® Systems 5,000 20,000 Hours of Operation 45,000 Lamp Lumens 40,000 35,000 Uni-Form® 320W Replace standard probe start 400 Watt with 30,000 20,000 Concrete Example: 320 Watt 25,000 Standard Probe Start HIDirect’s distribution center, located in Streetsboro, Ohio, replaced (20) 1000 watt standard probe start metal halide fixtures with (6) HIDirect® 875 watt pulse start metal halide fixtures in the shipping department area. 400W 15,000 5,000 10,000 15,000 20,000 Hours of Operation Realized Benefits: 22,000 Lamp Lumens 18,000 Replace standard probe start 250 Watt with 200 Watt Uni-Form® 200W • Saved $6,384 per year • Increased the light levels over 150% (2.5 times the illuminance level) 14,000 10,000 • Reduced the number of fixtures from 20 to 6 Standard Probe Start 250W • Saved over 140 watts of energy per fixture (Rated Lamp Life 10,000 Hours) 6,000 5,000 10,000 15,000 Hours of Operation Lamp Lumens 16,000 Uni-Form® 125W 12,000 8,000 Replace standard probe start 175 Watt with 125 Watt Standard Probe Start 175W (Rated Lamp Life 10,000 Hours) 4,000 5,000 10,000 15,000 Hours of Operation 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 39 Wiring Diagrams U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Uni-Form® Pulse Start Systems Wiring diagrams for all Uni-Form pulse start ballast products are provided on this page. The ballast data tables indicate the reference letter corresponding to the correct diagram for each ballast product. Refer to the table for the required ballast before referencing any diagram. The wiring diagram is the blueprint for the ballast circuitry, including the input supply voltage and grounding methods. A ground connection must be made to all ballasts to avoid shock hazard, personal injury or damage to the luminaire or installation. Ballast installations and groundings should be made in accordance with all applicable government codes and regulations where required. E K Y A1 B1 Q1 S1 T1 W1 UNI-FORM® Systems A 40 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Retrofit Systems U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S Ballast Housings and Track Lighting Benefits of Retrofitting • Ballast and components are pre-installed at the factory - Saves labor costs - Avoids unnecessary warranty issues • Cost is less than a new fixture • Less overall expense than retrofitting just lamp and ballast • Retaining your existing optics will preserve the same light pattern and dispersion - Avoids additional lighting layout cost 4. Heat shield 4 5. Mounting bracket 5 6 6. Open-rated (pink) socket 7. Open-rated lamp 8. White cord 7 UNI-FORM® Systems • Examples of open-rated optics that can be used: Sold with brackets to fit the following reflectors - All aluminum reflectors over 15” - All glass reflectors - All acrylic or polycarbonate refractors/reflectors over 16” Components of the Ballast Housing: 1 1. Hook 8 2.Wiring box with black cord 2 3. Ballast housing 3 • Higher lumen package than standard probe start metal halide Retrofit Systems Performance Plus™ 35W Metal Halide Track Lighting Fixture Use Your Existing Reflector & Save Time and Money! Savings 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 41 Retrofit Ballast Housings U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S ELECTRONIC BALLAST Housings 60Hz Ventronic™ Product Number OPE320HF208-277-(X) Voltage 208-277 Input Voltage 188-305 OPE350HF208-277-(X) 208-277 188-305 375 375/(.92*Vline) OPE400HF208-277-(X) 208-277 188-305 430 430/(.92*Vline) 277 249-305 465 465/(.92*Vline) OPE450HF277-(X) • Retail Auto Lots Line Side Characteristics • Highbay Industrial Lighting THD % Min Power Factor % Ballast Line Current Data (max @ low line) 320W Starting Current 320W Operating Current 350W Starting Current 350W Operating Current 400W Starting Current 400W Operating Current 450W Starting Current 450W Operating Current General information System Efficiency % Ballast Factor Light output at 35% Watts (Full Dim) • Aircraft Hangers • Indoor Sports/Recreation UNI-FORM® Systems Fig. 1 Tot. Wt. (lbs) 15 EMI FCC Part 18 M131 1 15 FCC Part 18 M155 1 15 FCC Part 18 M144 1 15 FCC Part 18 Notes: Sold with open rated socket and lamp. Shipped with 5 foot white cord. All ballast housings are shipped pre-wired to a specific voltage for the existing plug. If you are using a different voltage, the ballast will need to be re-wired. For direct wire/slice-box installations, remove cord and wire through wiring box. No plug or safety chain is provided. Use existing plug and safety chain or provide new components for installation. Options: Add Suffix for Options: QTZ - Quartz restrike control; D - Dimming; Standard, two wire 0-10V, DC control. Warranty and Standards: Electronic Ballast 3 years, Lamp 2 years. No warranty for quartz restrike lamp. See “One Call Warranty” for details UL Listed: Approved for damp location; Indoor open high bay applications only. Operating Temperature: -30º to 55ºC; Ambient per UL1598 Applications Benefits Compared to standard probe start systems: • Longer life • Energy savings • Improved color uniformity • Faster warm-up and restrike • Better lamp survival rates 208V in <5% 99 240V in <5% 99 277V in <5% 99 0.07 1.67 0.07 1.83 0.07 2.09 N/A N/A 0.07 1.45 0.07 1.59 0.07 1.81 N/A N/A 0.065 1.27 0.065 1.38 0.065 1.57 0.065 1.81 93 1 <12% 93 1 <12% 93 1 <12% 1 OPE Retrofit Systems Input Watts Maximum Line Current ANSI Code 342 342/(.92*Vline) M154 10.1 12.0 9.6 10.0 14.2 7.6 Weight = 15 lbs. Width = 12” Length = 10.1” Height = 14.2” System Benefits HIDirect’s retrofit ballast housings contain Uni-Form® pulse start metal halide lighting systems with patented formed body arc tube lamps and quieter, cool-running Opti-Wave® ballasts. 42 • Longer life - up to 50% longer than standard probe start metal halide • Energy savings - more system lumens per watt means more light for less energy • Improved color uniformity - for minimal color variation from lamp to lamp • Faster warm-up and restrike - one third the time • 70% survival at end of rated life - a 40% improvement over standard probe start metal halide - 80% survival for lamps on electronic ballasts • Fewer lamp failures and less breakage in shipping because of patented stronger weldless mount • Open-rated lamp (ANSI Type-O) - No luminaire lens required, delivers more light - Operational 24/7 - no shut-off required - Blocks nearly all damaging ultraviolet light with UV Shield® technology - Meets 2005 National Electric Code® criteria for open fixtures • Pleasant environment and better system performance thanks to quiet, cool-running Opti-Wave® ballasts 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Retrofit Ballast Housings U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S MAGNETIC BALLAST Housings 60Hz Watts 200 Input Voltage 277 Product No. OPM-2-200U ANSI Code M136 Circuit Type Reactor Input Watts 219 Max. Line Current 1.25 Fig. 2 Tot. Wt. (lbs) 11.5 14.5 200 120/208/240/277 OPM-3-200D(options) M136 HX-HPF 235 3.30/2.05/1.65/1.45 2 200 480 OPM-3-200Y M136 HX-HPF 235 0.8 2 15 250 277 OPM-2-250U M153 Reactor 275 1.35 2 13 250 120/208/240/277 17 320 277 320 320 OPM-1-250D(options) M153 CWA 288 2.50/1.45/1.25/1.10 2 OPM-2-320U M132/M154 Reactor 349 1.7 2 14 120/208/240/277 OPM-3-320D(options) M132/M154 HX-HPF 360 4.80/2.85/2.45/2.10 2 18 120/208/240/277 OPM-1-320D(options) M132/M154 CWA 365 3.15/1.85/1.60/1.40 2 18.5 320 120/277/347 OPM-1-320J(options) M132/M154 CWA 368 3.20/1.40/1.15 2 18.5 320 480 OPM-1-320Y M132/M154 CWA 370 1.2 2 18.5 480 OPM-3-320Y M132/M154 HX-HPF 370 1.2 2 18.5 350 277 OPM-2-350U M131 Reactor 380 1.9 2 14.4 350 120/208/240/277 OPM-3-350D(options) M131 HX-HPF 395 5.00/2.55/2.50/2.15 2 18 350 480 OPM-3-350Y M131 HX-HPF 400 1.35 2 21.5 400 277 18.5 400 120/208/240/277 400 450 OPHM-2-400U M155 Reactor 435 2.1 3 OPHM-1-400D(options) M155 CWA 450 4.00/2.30/2.00/1.75 3 20.2 480 OPHM-1-400Y M155 CWA 455 1 3 21.5 277 OPHM-2-450U M144 Reactor 485 2.3 3 17.6 120/208/240/277 450 480 575* 277 575* 120/208/240/277 575* OPHM-3-450D(options) M144 HX-HPF 505 7.00/3.60/3.50/3.00 3 23.5 OPHM-3-450Y M144 HX-HPF 515 1.75 3 23.5 OPHM-2-575U M178 Reactor 620 3.3 3 17.5 OPHM-3-575D(options) M178 HX-HPF 635 8.75/4.70/4.45/3.80 3 27.5 480 OPHM-3-575Y M178 HX-HPF 645 2.3 3 28 875* 480 OPHM-2-875Y M166 Reactor 925 2.75 3 23 875* 480 OPHM-1-875Y M166 CWA 945 2 3 30.5 875* 120/208/240/277 OPHM-1-875D(options) M166 CWA 940 8.00/4.50/4.00/3.45 3 30.5 • Indoor Highbay Lighting Benefits • Replacement standard probe start metal halide systems for energy saving pulse start systems! • Save up to 155 watts per luminaire • Acheive up to 115 lamp lumens per watt • Long life: 20,000+ hours = HIDirect’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007. * = Systems above 500 watts are exempt from California Title 20 and federal Energy Independence & Security Act of 2007 requirements. Notes: Sold with open rated socket and lamp. Shipped with 5 foot length white cord. All ballast housings are shipped pre-wired to a specific voltage for the existing plug. If you are using a different voltage, the ballast will need to be re-wired. For direct wire/slice-box installations, remove cord and wire through wiring box. No plug or safety chain is provided. Use existing plug and safety chain or provide new components for installation. Options: Add Suffix for Options: QTZ - Quartz restrike control; D - Dimming; Standard, two wire 0-10V, DC control. Warranty and Standards: Magnetic Ballast 5 years, Lamp 2 years. No warranty for quartz restrike lamp. See “One Call Warranty” for details UL Listed: Approved for damp location; Indoor open high bay applications only. Operating Temperature: -30º to 55ºC; Ambient per UL1598 12.0 10.0 10.7 15.3 Width = 12” Length = 10” Height = 15.3” OPHM 3 OPM 2 15.6 13.1 10.2 11.5 9.4 15.4 5.2 Width = 15.6” Length = 11.5” Height = 15.4” 4.6 11.5 10.0 43 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Retrofit Systems 450 Applications UNI-FORM® Systems 320 Track Lighting Systems U N I-FORM® P U L S E S T A R T M E T A L H A L I D E L I G H T I N G S Y S T E M S 35 Watt Electronic Track Lighting Systems # of Lamp Lamps Type Single MR16 Product Description VETF-J35W1-GX10-WH Part Center Beam Beam Beam Avg. Life CCT Number Candle Power Angle° Type Hours (K) 60622 23000cd 9 Very Narrow Spot 6000 5000 Twin MR16 VETF-J35W2-GX10-WH 60633 23000cd NOTE: Required HIDirect Lamp Parts # 60621, 60631, 60632 (figure 3) 9 Very Narrow Spot 6000 CRI 90+ 5000 System Input Connector Watts Voltage Fig. Type 43 120 1 J 90+ 87 120 2 J Performance Plus™ MR16 LAMPS Applications Lamp Lamp Type Description MR16 MPSE 35W/GX10/MR16/950/SP/WH Product Center Beam Number Candle Power 60621 23000 Beam Angle° 9 Beam Type Very Narrow Spot • Showcase Lighting MR16 MPSE 35W/GX10/MR16/950/NFL/WH 60631 • Track Lighting MR16 MPSE 35W/GX10/MR16/950/WFL/WH 60632 Avg. Life CCT Hours (K) 6000 5000 12500 20 Narrow Flood 6000 4800 40 Wide Flood 6000 CRI 90+ Fig. 3 Input Voltage 120 5000 90+ 3 120 5000 90+ 3 120 • Retail Lighting • Art Gallery/Museum Lighting Low Wattage Accent Lighting UNI-FORM® Systems Benefits of HIDirect’s electronic, low watt, metal halide track lighting systems for high powered accent lighting with less energy and more life and light The HIDirect Advantage • High efficiency • High CRI Retrofit Systems • Beam control: tight beam angle • Small size • Maximum punch • More choices across the visual color spectrum 2 FIXTURE Width = 9.9” (251mm) Height = 7.38” (187mm) Depth = 2.38” (60mm) Track Type = J 3 LAMP 1 FIXTURE • Direct from the manufacturer 12.52 Width = 12.52” (318mm) Height = 7.38” (187mm) Depth = 2.38” (60mm) Track Type = J 44 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com MR16 Dia. = 2.375” (60mm) MOL = 3.6” (92mm) Base = GX10 Specialty Lamps SPECIALTY METAL HALIDE LAMPS The Right Lamp For That Special Application Our Energy Master® Retrofit Lamps: Relamp your standard probe start metal halide installation with these 150 watt or 360 watt energy-saving retrofit products; lamps are specifically designed to operate with all standard probe start metal halide fixtures and ballasts. Energy saving pulse start lamps are also available. White-Lux® Lamps: 250 - 750 watts - Cost effectively switch from yellow HPS light to white metal halide light without modifications to your HPS ballasts and fixtures. Tubular Lamps: 70 - 1000 watts - Tubular jacketed lamps with highly streamlined profiles provide excellent optical control. BiPin (G12) Lamps: 70 - 150 watts Double Ended Lamps: 70 - 250 watts - Compact configuration provides excellent optical control in smaller fixture designs. High Wattage Double Ended Lamps: 1000 - 2000 Watts These European style lamps are used for large area floodlighting and sports lighting applications. High Wattage/Sports Lamps: 1000 - 1650 watts - These lamps are the leading choice for arenas and stadiums worldwide. Specialty Lamps Unique 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 45 ® gy Ener Master Lamps SPECIALTY METAL HALIDE LAMPS featuring UV Open Rated PROBE START LAMPS ANSI Type-O Shield® Lamp Watts Description 360 MPI 360W/BU/EM Product No. 38029 ANSI Initial Lumens Mean Avg. Life CCT Operating Case Watts Spec Lumens Per Watt Lumens Hours (K) CRI Finish Pos. Fig. Qty Replaces Saved M59/165/O 36000 100 23000 20000 4000 65 Clear BU±15° C 6 400/U; 400/BU 40 360 67293 M59/165/O 34000 MPI 360W/C/BU/EM 94 22000 20000 3700 70 Coated BU±15° C 6 400/C/U; 400/C/BU 40 ANSI Initial Lumens Mean Avg. Life CCT Operating Case Watts Spec Lumens Per Watt Lumens Hours (K) CRI Finish Pos. Fig. Qty Replaces Saved M57/107/E 13500 90 8800 10000 4000 65 Clear U A 12 175/U/MED 25 150 MH 150W/C/U/EM 39083 M57/107/E 12800 85 8300 10000 3700 70 Coated U A 12 175/C/U/MED 25 150 MH 150W/U/ED28/EM 69559 M57/107/E 13500 90 8800 10000 4000 65 Clear B 12 175/U; 175/BU 25 A B C BT37 Specialty Lamps • Energy Saving Applications Indoors or Outdoors Product No. 44810 ED28 Applications Lamp Watts Description 150 MH 150W/U/EM ED17 Enclosed Rated PROBE START LAMPS ANSI Type-E Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 46 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com U ® gy Ener Master Lamps SPECIALTY METAL HALIDE LAMPS Change Just The Lamp! Retrofit for Safety For applications where safety is an issue, HIDirect offers open-rated Energy Master® MPI (probe start) lamps, which meet 2005 NEC® (National Electric Code) requirements. The arc tube is enclosed within a quartz shroud to prevent the outer glass jacket from breaking in the event of an arc tube rupture, passing ANSI containment tests. These Lamp types are intended primarily for open-rated fixtures and provide an added measure of safety in enclosed fixtures. Retrofit Benefits: • No need to change luminaires or ballasts • Save on energy consumption • Safe alternative - Open-rated lamps available in 360 watt standard probe start metal halide lamps • Clear and coated outer jacket options available • Watch your energy savings grow with Energy Master! • Indoor or outdoor, Energy Master lamps are perfect for energy savings in any application Energy Savings A Simple Lamp Change Does It! Save Up to 40 watts per Fixture! Our Energy Master line of retrofit products saves energy by operating at lower wattages. See an immediate reduction in energy costs of up to 40 watts per fixture or a full 10% with virtually the same light output. For example, at a cost of $0.12/KWH, the energy savings over the rated life of the 360 watt Energy Master lamp (rated at 20,000 hours) is $64 per fixture. Calculation: .040 KW/hr x $.12 x 20,000 hrs = $96.00 Simple Change Just the Lamp! Considering an update of your lighting system? Explore the advantages of the Energy Master line - just replace your lamp. That’s it! The high cost of a whole new lighting system or the labor cost of re-wiring or installing new wiring is not needed with Energy Master energy saving retrofit lamps. Use existing luminaires and ballasts. Specialty Lamps 47 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com White-Lux Lamps ® SPECIALTY METAL HALIDE LAMPS featuring UV Open Rated PROBE START LAMPS ANSI Type-O Lamp Watts Description 250 MPI 250W/BU/LU Product ANSI Initial Lumens Mean Avg. Life CCT No. Compatible Lumens Per Watt Lumens Hours (K) CRI 24785 S50/O* 19000 70 12300 10000 4000 65 250 MPI 250W/C/BU/LU 10206 18000 67 11700 10000 3700 70 Coated BU±15° B 12 LU 250/C 400 MPI 400W/BU/LU 10044 S51/O** 39000 91 25400 20000 4000 65 E 6 LU 400 S50/O* Operating Case Finish Pos. Fig. Qty Clear BU±15° B 12 Shield® Clear BU±15° Replaces LU 250 Enclosed Rated PROBE START LAMPS ANSI Type-E Lamp Watts Description 250 MH 250W/U/LU • Parking lot lighting • Retail illumination operation and dimming capabilities. • Complete electrical compatibility with HPS systems • Designed for photometric compatibility with HPS systems • Clear and coated outer jacket options • Shrouded open-rated lamps available in 250 and 400 watts, complies with 2005 National Electric Code • Excellent color rendering (65-70 CRI vs. 22 CRI for HPS) MH 400W/U/LU/ED28 59441 S51/E** 41000 95 26600 20000 4000 65 Clear U A 12 LU 400 400 MH 400W/U/LU 52134 S51/E** 41000 95 26600 20000 4000 65 Clear U C 6 LU 400 400 MH 400W/C/U/LU 72190 S51/E** 39000 91 25400 20000 3700 70 Coated U C 6 LU 400/C 750 MH 750W/U/LU/BT37 33940 S111/E*** 72000 96 46800 12000 4000 65 Clear U D 6 LU 750 1000 MS 1000W/V/LU/BT37 35892 110 71500 15000 4000 65 Clear V±15 D 6 LU 1000 * ** *** † S52/E† 110000 Lamp operates on 250W(S50) high pressure sodium ballast. Lamp operates on 400W(S51) high pressure sodium ballast. Lamp operates on 750W(S111) high pressure sodium ballast. Lamp operates on 1000W(S52) high pressure sodium ballast. A Simple Lamp Change Does It It’s easier than ever to switch from the harsh yellow light of high pressure sodium to the clear, white light of metal halide. Make the change just by replacing the lamp! HIDirect’s unique White-Lux lamps are completely compatible with all HPS lighting systems and fit directly into your existing 250, 400, 750 or 1000 watt HPS fixture. No need to change ballasts, ignitors, or even reposition the socket. The crisp, 4K color of White-Lux replacement lamps reduces glare in your warehouse or building and creates a better, brighter work environment. Reduce errors and improve your business efficiency with this simple change to whiter light. White-Lux high output metal halide lamps are the easy, cost-effective solution to your retrofit needs. Save on costs, increase productivity, raise sales. You’re sure to see the bright results with the White-Lux advantage! Switch To Bright, White Light From Existing HPS Fixtures As Simple As A Change Of A Lamp A B ED28 Specialty Lamps Change Just the Lamp: Replaces LU 250 400 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 C D E BT37 • Warehouse downlighting Operating Case Pos. Fig. Qty U A 12 BT37 • Building and security floodlighting Finish Clear ED37 • Industrial highbay ED28 Applications Product ANSI Initial Lumens Mean Avg. Life CCT No. Compatible Lumens Per Watt Lumens Hours (K) CRI 91051 S50/E* 20000 74 13000 10000 4000 65 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 48 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 High Wattage/Sports SPECIALTY METAL HALIDE LAMPS Enclosed Rated PROBE START LAMPS ANSI Type-E Mogul Base Watts 1000 Lamp Description MS 1000W/HOR/SPORT 60 Product No. 47503 ANSI Code M47/E Initial Lumens 115000 Mean Lumens 86000 1000 MS 1000W/HOR/BT37/3K 53702 M47/E 115000 86000 3400 70 Clear HOR±45° C 6 1500 MH 1500W/HBU 18360 M48/E 161000BU 136000BU 3000BU/H 3400 65 Clear BU±105° A 6 57 1500 MH 1500W/U/XL 12342 M48/E 170000V Clear U A 6 57 1500 MS 1500W/HOR/XP/SPORT 60 82070 M48/E 162000 137700 3000 3400 70 Clear HOR±60° B 6 57 1650 MS 1650W/HOR/XP/SPORT 60 16419 M112/E 177000 145000 3000 3200 70 Clear HOR±60° B 6 57 136000V Avg. Life CCT Hours (K) CRI 12000 3400 70 12000 6000V Operating Case Ballast Finish Position Fig. Qty Ref. Pg. Clear HOR±60° B 6 57 4000 65 57 Benefits: • Brighter - High lumen output • “Extra Life” lamp available HIDirect’s MH 1500W/U/XL lamp has a 6000 hour rated life • HIDirect’s Sports 60 lamps are designed for sports lighting aiming angles Electrical Connections: HIDirect offers a wide range of Sports Lighting options, including the compact MS 1000/HOR/BT37 designed for indoor arenas and the 1500 and 1650 watt Sport 60 lamps for applications in both recreational and professional athletic sites. • Weldless key electrical connections maintain lamp circuit integrity, even when subjected to pole-top noise, vibration and harshness (NVH) Structurally Stronger: • Less color shift • Weldless frame connections minimize shipping damage and claims • Increases voltage stability Dia. = 7” (180mm) MOL = 15 3/8” (391mm) LCL = 9 1/2” (241mm) Base = E39 • Improves performance • Good color rendition (65-70 CRI) • High Wattage double ended versions available Spec the System: Matching lamp and ballast specs available C BT37 BT56 B BT56 A Electrically Neutral Frame: • High lumen output lamps for efficient layout designs Dia. = 7” (180mm) MOL = 15 3/8” (391mm) LCL = 9 1/2” (241mm) Base = EP39 (POMB) Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) 49 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Specialty Lamps A Simple Lamp Change Does It • Compact BT37 for excellent optical control (MS 1000/HOR/BT37) Tubular Lamps SPECIALTY METAL HALIDE LAMPS Enclosed Rated PROBE START LAMPS ANSI Type-E Watts 175 Lamp Description MH 175W/U/T15 Product No. 40335 ANSI Code M57/E 175 MH 175W/U/T15/10K 70136 M57/E - - - 250 MH 250W/U/T15 33479 M58/E 21000 84 13700 250 MH 250W/U/T15/10K 63897 M58/E - - - 250 MS 250W/HOR/T15* 88353 M58/E 23000 92 250 MS 250W/HOR/T15/3K* 54843 M58/E 21000 84 400 MH 400W/U/T15 55422 M59/E 36000 90 • Landscape Lighting 400 MS 400W/HOR/T15* 55100 M59/E • Downlighting - Low Ceiling 400 MS 400W/HOR/T15/3K* 32225 M59/E Applications • Sconce Lighting CCT (K) 4000 CRI Finish 65 Clear 8000 10000 65 Clear U A 10000 4000 65 Clear U A 12 56 8000 10000 65 Clear U A 12 56 15000 10000 4000 65 Clear HOR±45° A1 12 56 13700 10000 3200 65 Clear HOR±45° A1 12 56 23000 15000 4000 65 Clear B 12 57 40000 100 26000 15000 4000 65 Clear HOR±45° B1 12 57 38000 95 15000 3200 65 Clear HOR±45° B1 12 57 24000 Oper. Pos. U ® 12 56 TECHNOLOGY Watts 200 Lamp Description MS 200W/H75/T15/PS/740 Product No. 70764 ANSI Code M136/E Initial Lumens Mean Avg. Life Lumens Per WattLumens Hours 19000 95 15200 15000 250 MS 250W/H75/T15/PS/740 57625 M153/E 22000 88 17600 15000 4000 68 Clear HOR±75° D 12 29 320 MS 320W/H75/T15/L/PS/740 79710 M154/E 30000 94 24000 20000+ 4000 68 Clear HOR±75° E 12 31 320 MS 320W/H75/T15/S/PS/740 57626 M154/E 30000 94 24000 20000+ 4000 68 Clear HOR±75° D 12 31 350 MS 350W/H75/T15/PS/740 93749 M131/E 33000 94 26000 20000+ 4000 68 Clear HOR±75° E 12 33 1000 MS 1000W/HOR/T25/PS/734* 49111 M141/E * Permitted rotation about horizontal lamp axis ±15Ëš. 110000 110 77000 3400 68 Clear HOR±45° F 6 Dia. = 1 7/8” (46mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 A1 = EP39 (POMB) Dia. = 1 7/8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E39 B1 = EP39 (POMB) C D E T15 T15 T15 B T15 A 5000 Oper. CaseBallast CRI Finish Pos. Fig. QtyRef. Pg. 68 Clear HOR±75° C 12 28 T15 It is energy-efficient to turn off a fluorescent light only if it will not be used again within an hour or more. This is because of the high voltage needed to turn it on, and the shortened life this high voltage causes. CCT (K) 4000 CaseBallast Fig. Qty Ref.Pg. A 12 56 U Enclosed Rated PULSE START LAMPS ANSI Type-E UNI-FORM Fun Facts Dia. = 1 7/8” (46mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 1 7/8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E39 F T25 Specialty Lamps Initial Lumens Mean Avg. Life Lumens Per WattLumens Hours 14000 80 9100 10000 Dia. = 3 1/8” (79mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) 50 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Dia. = 1 7/8” (46mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 38 Double Ended & G12 SPECIALTY METAL HALIDE LAMPS Enclosed Rated PULSE START* SINGLE ENDED LAMPS (G12) ANSI Type-E Lamp Description HIT 70W/G12/UVS/3K Product No. 12108 ANSI Initial Lumens Mean Avg. Life CCT Code Lumens Per Watt Lumens Hours (K) M85/M98/E 5600 75 3600 10000 3000 CRI Finish 70 Clear Operating Case Pos. Fig. Qty U A 25 Ballast Ref. Pg. 23 HIT 70W/G12/UVS/4K 52983 M85/M98/E 5600 75 3600 10000 4200 70 Clear U A 25 23 HIT 100W/G12/UVS/4K 89887 M90/E 9000 90 5900 10000 4200 70 Clear U A 25 24 HIT 150W/G12/UVS/3K 12106 M81/M102/E 14000 93 10500 10000 3000 70 Clear U A 25 26 HIT 150W/G12/UVS/4K 25779 M81/M102/E 14000 93 10500 10000 4200 70 Clear U A 25 26 Enclosed Rated PULSE START* DOUBLE ENDED LAMPS RSC (R7s) ANSI Type-E Applications Lamp Description MH-DE 70W/UVS/3K Product No. 16786 ANSI Initial Lumens Mean Avg. Life CCT Code Lumens Per Watt Lumens Hours (K) M85/M98/E 5200 69 3400 10000 3000 Operating Case CRI Finish Pos. Fig. Qty 70 Clear HOR±45° B 25 • Landscape Lighting MH-DE 70W/UVS/4K 60248 M85/M98/E 5500 70 73 3600 10000 4200 Clear HOR±45° B 25 Ballast Ref. Pg. 23 23 MH-DE 70W/UVS/FS/6K 79470 M85/M98/E 4800 64 4100 10000 6500 90 Clear HOR±45° B 25 23 MH-DE 150W/UVS/3K 11295 M81/M102/E 11250 75 8400 10000 3000 70 Clear HOR±45° C 25 26 MH-DE 150W/UVS/4K 74756 M81/M102/E 11250 75 8400 10000 4200 70 Clear HOR±45° C 25 26 MH-DE 150W/UVS/FS/6K 29963 M81/M102/E 11250 75 9600 10000 6500 90 Clear HOR±45° C 25 26 • Downlighting - Low Ceiling • Sconce Lighting Enclosed Rated PULSE START DOUBLE ENDED LAMPS RSC (RX7s), Fc2 ANSI Type-E Product No. 84727 ANSI Code M80/E Initial Lumens Mean Avg. Life CCT Lumens Per Watt Lumens Hours (K) 20000 80 13000 10000 3000 Operating Case CRI Finish Pos. Fig. Qty 70 Clear HOR±45° E 25 Ballast Ref. Pg. 28 MH-DE 250W/UVS/4K/Fc2 72748 M80/E 20000 80 13000 10000 4200 70 Clear HOR±45° E 25 28 MH-DE 250W/UVS/4K/RSC 22468 M80/E 20000 80 13000 10000 4200 70 Clear HOR±45° D 25 28 * UNI-FORM ® T E C H N O L O G Y Dia. = 23mm MOL = 110mm LCL = 56mm Base = G12 Contact to Contact = 114.2mm Base = RSC (R7s) Contact to Contact = 132mm Base = RSC (R7s) It is energy-efficient to turn off a fluorescent light only if it will not be used again within an hour or more. This is because of the high voltage needed to turn it on, and the shortened life this high voltage causes. MOL = 163.7mm Base = RSC (RX7s) MH-DE E MH-DE D MH-DE C MH-DE B G12 A Fun Facts MOL = 163mm Base = Fc2 EUROPEAN USAGE: 70, 100, 150, 250 watt lamps operate on HPS ballasts with MH ignitors 51 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Specialty Lamps Lamp Description MH-DE 250W/UVS/3K/Fc2 High Watt Double Ended SPECIALTY METAL HALIDE LAMPS Enclosed Rated PULSE START LAMPS ANSI Type-F M___/F Watt 1000 Lamp Description MBIL S 1000W Product No. 22417* ANSI Initial Lumens Code Lumens Per Watt M__/F** 80000 80 Mean Avg. Life CCT Lumens Hours (K) 64000 6000 5200 CRI 65 Finish Frosted Operating Position HOR±15° Fig. A Case Qty 6 1500 MBIL S 1500W 22151* M__/F** 130000 87 104000 6000 5200 65 Frosted HOR±15° B 6 2000 MBIL S 2000W 22132* M__/F** 215000*** 100 172000 6000 5200 65 Frosted HOR±15° C 2 * Approved ballasts are 1000W - M141, 1500W - M133 or M48 with an ignitor, 2000W - M134 ** F - ANSI code for lamps which must be used in enclosed luminaires with UV attenuating lenses. WARNING: Do not operate this lamp if the lens is broken or missing since the unattenuated UV from this lamp can cause serious skin burn and eye inflammation. Applications • Site Lighting ***MBIL 2000 watt lamps are measured at 2150 watts. • Sports and Recreation Lighting European Usage: High Wattage Double Ended Lamps operate on reactor ballasts with MH ignitors. MAGNETIC BALLASTS 60Hz Input Product ANSI Circuit Input Max. Line UL Coil Wiring Dimensions Wt. Total Cap. Cap. Cap. Ign.Max.Dist. Watts Voltage No. Code Type Watts Current Rise Code Diag. Fig. A (in) B (in) (lbs)(µfd/Vmin) Fig. Type Fig. (ft) 1000 120/208/240/277 V90D7810 M141 CWA 1080 9.00/5.20/4.50/3.90 D/A/B/B E 1 2.8 4.8 21 24/480 B12 Oil F 10 1000 120/208/240/277 V90D7811 M141 CWA 1080 8.95/5.55/4.55/3.95 D/D/C/D 1000 120/277/347 V90J7810 M141 CWA 1080 480/120T V90Y7810T M141 CWA 1080 1000 480/120T V90Y7811T M141 CWA 1085 2000 480 V90Y6810 M134 CWA 2150 1 2.8 4.95 18.5 24/480 CWA 6.00" (152 mm) K 1 2.93 4.95 21.5 24/480 B12 Oil F 10 S1 1 2.82 4.85 B12 Oil F 10 2.35 E S1 1 2.8 4.85 21 24/480 B12 Oil F 10 4.70 E A 1 44 44/510 B10 Oil G 12 6 8.2 4.25" (108 mm) 3.87" (98 mm) 4.375" (111 mm) 5.375"(136 mm) A B MBIL S MOL = 256mm Effective arc length = 168mm Base = RSC (RX7s) HOLES CLEARED FOR #10 BOLTS 10 D C 1 4x6 Core F D/B/A MBIL S MOL = 256mm Effective arc length = 183mm Base = RSC (RX7s) Oil 2.25 B MBIL S A B12 9.00/3.90/3.15 Specialty Lamps 1000 E MOL = 311mm Effective arc length = 191mm Base = SINGLE CONTACT-SPECIAL Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #40 52 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 21 24/480 Probe Start Metal Halide STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S The Best Lamps Features HIDirect offers the widest range of standard probe start metal halide products, including North American and European style lamps. With over twenty years of experience, HIDirect’s high quality lamps are used worldwide. • Vacuum impregnation for cooler operation of optimized insulation system This section provides complete data for North American medium and mogul base 175W, 250W, 400W, 1000W 1500W and 1650W standard probe start metal halide lamps. • UL Temp Codes equal to or better than the competition • User-friendly installation - Color coded wires as well as printed labels on the wires make for easy installing - just follow the diagram on each ballast • The core size to meet your application - same sizes as competitors in the same ballast type • Dry capacitors rated up to 100° C The Right Ballasts HIDirect offers a wide selection of CWA and CWI probe start metlal halide ballasts. Products are available in single, dual, tri and quad tap ballasts to cover the lighting voltages of 120V, 208V, 240V, 277V, 347V and 480V. • Flexibility: Order kits, prewired ballasts, brackets - all in the configuration that you need • Thermally protected ballasts available for most pulse start metal halide ballasts All ballast specifications are in compliance with North American and international safety, performance and design standards, including U.L., CSA and ANSI. In Europe, all products carry the CE mark, and many of our products carry approval marks, including ENEC, Kitemark and VDE. Probe Start MH Systems Magnetic 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 53 Probe Start Metal Halide STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O Lamp Watts Description 175 MPI 175W/BU Product No. 32519 175 MPI 175W/C/BU 250 MPI 250W/BU 250 MP1 250W/C/BU Shield® ANSI Code M57/O Initial Lumens Mean Avg. Life Lumens Per Watt Lumens Hours 14000 80 9100 10000 CCT (K) 4000 CRI 65 Finish Clear Operation Position BU±15° Fig. C Case Qty 12 32520 M57/0 13300 76 8600 10000 3700 70 Coated BU±15° C 12 60722 M58/O 21800 87 14200 10000 4000 65 Clear BU±15° C 12 60723 M58/0 20700 83 13500 10000 3700 70 Clear BU±15° C 12 Operation Position U Fig. A Case Qty 12 Enclosed Rated LAMPS ANSI Type-E Features Lamp Watts Description 175 MH 175W/U/MED Product No. 15556 ANSI Code M57/E Initial Lumens Mean Avg. Life Lumens Per Watt Lumens Hours 14000 80 9100 10000 CCT (K) 4000 CRI 65 Finish Clear 175 MH 175W/C/U/MED 63187 M57/E 13300 76 8600 10000 3700 70 Coated U A 12 175 MS 175W/BU/MED 70310 M57/E 15000 86 9800 10000 4000 65 Clear BU±15° A 12 175 MS 175W/C/BU/MED/3K 52522 M57/E 13600 78 8800 10000 3200 70 Coated BU±15° A 12 175 MH 175W/U 88791 M57/E 14000 80 9100 10000 4000 65 Clear U B 12 175 MH 175W/C/U 96627 M57/E 13300 76 8600 10000 3700 70 Coated U B 12 175 MH 175W/U/5K 79881 M57/E 12000 69 7800 7500 5000 75 Clear U B 12 Applications 175 MS 175W/BU 55087 M57/E 15000 86 9800 10000 4000 65 Clear BU±15° B 12 • Floodlighting • Warehouse • ParkingGarage 175 MS 175W/C/BU/3K 20981 M57/E 13600 78 8800 10000 3200 70 Coated BU±15° B 12 175 MS 175W/HOR* 57330 M57/E 15000 86 9800 10000 4000 65 Clear HOR±45° F 12 175 MH 175W/U/T15 40335 M57/E 14000 80 9100 10000 4000 65 Clear U K 12 175 MH 175W/U/T15/10K 70136 M57/E - - - 8000 10000 65 Clear U K 12 250 MH 250W/U 63052 M58/E 21000 84 13700 10000 4000 65 Clear U B 12 250 MH 250W/C/U 61290 M58/E 20000 80 13000 10000 3700 70 Coated U B 12 250 MH 250W/U/5K 27252 M58/E 19000 76 12400 7500 5000 75 Clear U B 12 Did you know… 250 MS 250W/BU 36297 M58/E 23000 92 15000 10000 4000 65 Clear BU±15° B 12 Every time you turn on a light switch 72% of the energy comes from coal 250 MS 250W/C/BU/3K 18477 M58/E 20000 80 13000 10000 3200 70 Coated BU±15° B 12 250 MS 250W/HOR* 94883 M58/E 23000 92 15000 10000 4000 65 Clear HOR±45° F 12 250 MS 250W/HOR/T15/3K* 54843 M58/E 21000 84 13700 10000 3200 65 Clear HOR±45° N 12 250 MH 250W/U/T15 33479 M58/E 21000 84 13700 10000 4000 65 Clear U K 12 250 MS 250W/HOR/T15* 88353 M58/E 23000 92 15000 10000 4000 65 Clear HOR±45° N 12 250 MH 250W/U/T15/10K 63897 M58/E - - - 8000 10000 65 Clear U K 12 Probe Start MH Systems • Full range of wattages • Clear and coated versions • Reduced jacket options * Permitted rotation about horizontal lamp axis ±15Ëš 54 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EP39 (POMB) Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EX39 Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 ED37 H Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) BT37 E ED37 ED28 Dia. = 3 1/2” (90mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 G ED28 F D BT37 Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 3/8” (86mm) Base = E26 C ED28 B ED17 A Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EX39 Probe Start Metal Halide STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S featuring UV Open Rated LAMPS ANSI Type-O Shield® Lamp Watts Description 400 MPI 400W/BU Product No. 95527 ANSI Code M59/O Initial Lumens Mean Avg. Life Lumens Per Watt Lumens Hours 40000 100 26000 20000 CCT (K) 4000 CRI 65 Finish Clear Operation Position BU±15° Fig. E Case Qty 6 400 26091 M59/O 38000 3700 70 Coated BU±15° E 6 MPI 400W/C/BU 95 25000 20000 Enclosed Rated LAMPS ANSI Type-E Product No. 57540 ANSI Code M59/E Initial Lumens Mean Avg. Life Lumens Per Watt Lumens Hours 36000 90 23000 20000 CCT (K) 4000 CRI 65 Finish Clear Operation Position U Fig. B Case Qty 12 400 MH 400W/C/U/ED28 20753 M59/E 34000 85 22000 20000 3700 70 Coated U B 12 400 MS 400W/BU/ED28 40013 M59/E 40000 100 26000 20000 4000 65 Clear BU±15° B 12 400 MH 400W/U/ED28/10K 27540 M59/E - - - 8000 10000 65 Clear U B 12 400 MS 400W/HOR/ED28* 21929 M59/E 40000 100 26000 20000 4000 65 Clear HOR±45° F 12 400 MS 400W/C/HOR/ED28* 24573 M59/E 38000 95 24000 20000 3700 70 Coated HOR±45° F 12 400 MH 400W/U 18520 M59/E 36000 90 23000 20000 4000 65 Clear U D 6 400 MH 400W/C/U 83545 M59/E 34000 85 22000 20000 3700 70 Coated U D 6 400 MH 400W/U/5K 36813 M59/E 32500 81 21000 15000 5000 75 Clear U D 6 400 MS 400W/HOR* 40509 M59/E 40000 100 26000 20000 4000 65 Clear HOR±45° G 6 400 MS 400W/C/HOR* 64648 M59/E 38000 95 24000 20000 3700 70 Coated HOR±45° G 6 400 MS 400W/HOR/T15* 55100 M59/E 40000 100 26000 15000 4000 65 Clear O 12 400 MH 400W/U/T15 55422 M59/E 36000 90 23000 15000 4000 65 Clear U L 12 400 MS 400W/HOR/T15/3K* 32225 M59/E 38000 95 24000 15000 3200 65 Clear HOR±45° O 12 1000 MH 1000W/U 72051 M47/E 110000 110 71000 12000 4000 65 Clear U I 6 1000 MH 1000W/C/U 88460 M47/E 105000 105 68000 12000 3700 70 Coated U I 6 1000 MH 1000W/U/5K 35914 M47/E 80000 80 52000 9000 5000 75 Clear U I 6 1000 MH 1000W/U/BT37 15332 M47/E 110000 110 71000 12000 4000 65 Clear U J 6 1000 MS 1000W/BU 89113 M47/E 115000 115 74000 12000 4000 65 Clear BU±15° I 6 1000 MS 1000W/BU/BT37 13090 M47/E 115000 115 74000 12000 4000 65 Clear BU±15° J 6 1000 MS 1000W/HOR/BT37/3K* 53702 M47/E 115000 115 86000 12000 3400 70 Clear HOR±45° H 6 1000 MS 1000W/HOR/SPORT 60 47503 M47/E 115000 115 86000 12000 3400 70 Clear HOR±60° M 6 1000 MS 1000W/BU/T25 78952 M47/E 110000 110 66000 5000 4000 65 Clear BU±15° P 6 1500 MH 1500W/HBU 18360 M48/E 161000BU 107 136000BU 3000BU/H 3400 65 Clear BU±105° I 6 1500 MH 1500W/U/XL 12342 M48/E 170000V 113 136000V 6000V 4000 65 Clear U I 6 M48/E 162000 108 137700 3000 3400 70 Clear HOR±60° M 6 1650 MS 1650W/HOR/XP/SPORT 60 16419 M112/E 177000 * Permitted rotation about horizontal lamp axis ±15Ëš 107 145000 3000 3200 70 Clear HOR±60° M 6 K Dia. = 7” (180mm) MOL = 15 3/8” (391mm) LCL = 9 1/2” (241mm) Base = E39 Dia. = 7” (180mm) MOL = 15 3/8” (391mm) LCL = 9 1/2” (241mm) Base = EP39 (POMB) • Architectural Downlighting • Site Lighting Fun Facts It is energy-efficient to turn off a fluorescent light only if it will not be used again within an hour or more. This is because of the high voltage needed to turn it on, and the shortened life this high voltage causes. T15 Dia. = 1 7⁄8” (46mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = E39 Dia. = 1 7⁄8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E39 P T15 O T15 N BT56 M Dia. = 4 5/8” (120mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = E39 Applications L T15 BT37 J BT56 I • Reduced jacket options • Burn positions include universal, horizontal and vertical Dia. = 1 7⁄8” (46mm) MOL = 8 5/16” (211mm) LCL = 5” (127mm) Base = EP39 (POMB) Dia. = 1 7⁄8” (46mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = EP39 (POMB) T25 1500 MS 1500W/HOR/XP/SPORT 60 82070 HOR±45° Features Probe Start MH Systems Lamp Watts Description 400 MH 400W/U/ED28 Dia. = 3 1/8” (79mm) MOL = 11 1/2” (292mm) LCL = 7” (178mm) Base = EP39 (POMB) 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 55 Probe Start Metal Halide STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S MAGNETIC BALLASTS 60Hz Watts 175 Input Voltage 120 Product ANSI Circuit Input No. Code Type Watts V90B6112 M57 CWA 206 Max. Line Current 1.85 175 480 V90Y6111T M57 CWA 211 0.45 B V1 1 2.22 3.6 6.8 175 600 V90Z6150 M57 0.40 D O 1 2.65 4.13 9 H 1 2.22 3.6 CWI 226 UL Coil Wiring Dimensions Total Wt. Capacitor Cap. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. C B 1 2.4 3.8 6.6 10/400 A11 175 120/208/240/277 V90D6111 M57 CWA 210 1.80/1.10/0.90/0.80 C/D/D/C 175 120/208/240/277 V90D6112 M57 CWA 215 1.85/1.10/0.90/0.80 B/C/C/B Oil 6.8 10/400 A11 Dry Dry H 1 2.4 3.8 7 10/400 A11 W 1 2.65 4.13 9 9/520 V90J6111 M57 CWA 210 1.80/0.80/0.65 B/B/C M 1 2.22 3.6 V90J6112 M57 CWA 210 1.90/0.80/0.65 C/D/D M 1 2.4 3.8 C O 1 2.65 4.13 9 B5 Oil D V1 1 3 4.4 9.1 15/360 A12 Dry 175 120/277/347 • Signage 175 120/277/347 • Canopies 175 208/120T 226 1.10 • Industrial 250 480 V90Y6211 M58 CWA 288 0.60 600 V90Z6250 M58 0.50 D V90E6150 M57 V90P6150T M57 CWI 225 CWI CWI 303 B5 Oil 6.8 10/400 A11 Dry 7 10/400 A11 Dry 9/520 O 2 2.16 3.75 14 12/480 B8 Oil 250 120/208/240/277 V90D6211 M58 CWA 291 2.60/1.45/1.30/1.10 B/A/C/B H 1 2.8 4.2 8.5 15/360 A12 Dry 250 120/208/240/277 V90D6212 M58 CWA 289 2.50/1.45/1.25/1.10 B/B/B/B H 2 1.65 3.25 9.3 15/400 A12 Dry 250 120/208/240/277 V90D6215 M58 CWA 290 2.60/1.50/1.30/1.15 A/A/A/A Dry H 2 1.46 3.3 8.3 15/400 A12 2.60/1.30 A/A W 2 2.16 3.75 14 12/480 B8 Oil V90J6211 M58 CWA 293 2.50/1.10/0.90 A/D/C M 1 2.8 4.2 8.5 15/360 A12 Dry V90J6212 M58 CWA 289 2.50/1.10/0.90 A/A/A M 2 1.65 3.3 9.3 15/360 A12 Dry A P 2 2.16 3.75 14 12/480 B8 Oil B V1 2 1.55 3.35 8.8 15/400 A12 Dry 250 120/240 V90E6250 M58 250 120/277/347 250 120/277/347 250 208/120T V90P6250T M58 303 1.50 250 480/120T V90Y6212T M58 CWA 295 0.60 CWA/CWI 1 3x4 Core 3.94" (100mm) 2.44" (62 mm) CWI 303 CWI Ballast Options 2 4x4 Core HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) A B CWA/CWI Probe Start MH Systems Dry B5 B/B 120/240 250 9/520 1.90/0.95 175 Applications 10/400 A11 Cap. Type Dry 4.75" (121 mm) 3.87" (98 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B 56 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #58 Probe Start Metal Halide STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S MAGNETIC BALLASTS 60Hz Input Voltage 600 Watts 400 Product ANSI Circuit Input No. Code Type Watts V90Z6450T M59 CWI 475 Max. Line Current 0.80 UL Coil Wiring Dimensions Total Wt. Capacitor Cap. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. C O 1 3.5 5.5 21 19.5/520 B12 Cap. Type Oil 400 120/208/240/277 V90D6413 M59 CWA 455 4.00/2.30/2.00/1.75 D/D/E/E H 1 2 3.9 10.7 24/360 A13 400 120/208/240/277 V90D6414 M59 CWA 455 3.95/2.30/2.00/1.75 D/D/E/E H 1 2 3.9 10.7 24/360 A13 Dry 400 120/208/240/277 H 1 2 3.9 11.7 24/360 B13 Dry V90D6412 M59 CWA 452 4.00/2.30/2.00/1.75 C/D/D/D 400 120/240 400 120/277/347 V90E6450 M59 CWI 475 400 208/120T V90P6450T M59 400 480/120T 1000 208 V90P6550T M47 CWI 1100 5.70 1000 600 V90Z6550 M47 CWI 1100 2.00 Dry 4.05/2.05 B/B W 1 3.5 5.5 21 19.5/520 B12 Oil 4.00/1.75/1.40 C/E/E M 1 2.15 3.9 11.4 24/360 A13 Dry 475 2.35 C P 1 3.5 5.5 21 19.5/520 B12 Oil Features V90Y6413T M59 CWA 457 1.00 E V1 1 2.15 4.1 11.5 24/360 A13 Dry C P 2 4.5 6 31 24/480 B12 Oil • North American and European styles B O 2 4.5 6 31 24/480 B12 Oil 1000 120/208/240/277 V90D6514 M47 CWA 1080 9.00/5.20/4.50/3.90 D/A/A/A H 2 2.8 4.8 20.5 24/480 B12 Oil 1000 120/208/240/277 V90D6516 M47 CWA 1085 8.80/5.00/4.60/3.90 D/A/B/C H 1 3.25 5.45 18.5 24/450 B12 Oil 1000 120/208/240/277 V90D6517 M47 CWA 1085 9.00/5.50/4.60/4.00 D/D/C/C H 2 2.8 4.95 18.5 24/480 B12 Oil Applications 1000 120/240 F/F W 2 4.5 6 31 24/480 B12 Oil • Big Box Retail 1000 120/277/347 D/B/A M 2 2.9 4.95 21.5 24/480 B12 Oil • Security 1000 480/120T V90Y6514T M47 CWA 1080 2.25 C V1 2 2.82 4.85 21 24/480 B12 Oil • Industrial 1000 480/120T V90Y6517T M47 CWA 1085 2.30 D V1 2 2.8 4.9 18.5 24/480 B12 Oil 1500 480 V90Y6612T M48 CWA 1605 3.40 E V90J6413 M59 CWA 455 V90E6550 M47 CWI CWI 1100 10.00/5.00 V90J6514 M47 CWA 1080 9.00/3.90/3.15 V1 2 4.2 6.2 31 32/525 B14 Oil 1500 120/208/240/277 V90D6612 M48 CWA 1625 13.40/7.75/6.70/5.80 G/E/E/E H 2 4.1 6.1 31 32/525 B14 Oil 1650 120/208/240 V90C6910 M112 CWA 1760 16.40/9.45/8.20 F/D/C D 2 4.5 6.55 32.1 (2X) 32/570 B9 Oil 1650 277/347/480 V90AA6910 M112 CWA 1760 7.00/5.60/4.00 E/F/H J 2 4.5 6.6 32.1 (2X) 32/570 B9 Oil 3.87" (98 mm) Ballast Options 2 4x6 Core HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B CWA/CWI CWA/CWI 4.75" (121 mm) 6.00" (152 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 3.87" (98 mm) Probe Start MH Systems 1 4x4 Core 4.375" (111 mm) 5.375"(136 mm) A B Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #58 57 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Wiring Diagrams STANDARD P R O B E S TA RT M E TA L H A L I D E L I G H T I N G S Y S T E M S Wiring Diagrams Probe Start MH Systems Wiring diagrams for all of HIDirect’s probe start standard metal halide ballast products are provided on this page. The ballast data tables indicate the reference letter corresponding to the correct diagram for each ballast product. Refer to the table for the required ballast before referencing any diagram. The wiring diagram is the blueprint for the ballast circuitry, including the input supply voltage and grounding methods. A ground connection must be made to all ballasts to avoid shock hazard, personal injury or damage to the luminaire or installation. Ballast installations and groundings should be made in accordance with all applicable government codes and regulations where required. B D H J M O P W V1 58 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com HPS Lamps HIGH PRESSURE SODIUM LAMPS AND BALLASTS HIGH PRESSURE SODIUM LAMPS Wattage 70W Lamp Description HPS070/U CLEAR Product No. 84762 ANSI CODE S62 Initial Lumens 6000 Avg. Life Hours 24000+ CCT (K) 2100 Fig. B S62 6400 24000+ 1900 A 25472 S54 9500 24000+ 2000 B 100W LU 100/MED 69456 S54 9500 24000+ 2000 A 100W HPS100/U/MED CLEAR 69457 S54 9000 24000+ 2100 A 150W LU 150/55 64616 S55 16000 24000+ 2000 B 150W HPS150/U/MED CLEAR 28639 S55 15000 24000+ 2100 A 250W LU 250 35946 S50 28000 24000+ 2100 C 400W LU 400 17934 S51 51000 24000+ 2100 C 1000W HPS1000/U CLEAR 86346 S52 140000 24000+ 2100 D Dia. = 2 1/8” (54mm) MOL = 5 7/16” (138mm) LCL = 3 7/16” (87mm) Base = E26 B C D Dia. = 2 15/16” (75mm) MOL = 7 3/4” (197mm) LCL = 5” (127mm) Base = E40 Dia. = 2 1/4” (57mm) MOL = 9 3/4” (248mm) LCL = 5 3/4” (146mm) Base = E40 HPS Lamps and Ballasts ED17 A ET25 51918 LU 100 ED18 LU 70/MED 100W ED23.5 70W Dia. = 3 1/8” (79mm) MOL = 15 1/16” (383mm) LCL = 8 3/4” (222mm) Base = E40 59 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com HPS Ballasts HIGH PRESSURE SODIUM LAMPS AND BALLASTS HIGH PRESSURE SODIUM BALLASTS 60Hz Watts 35 Applications Input Voltage 120 Product ANSI Circuit Input No. Code Type Watts V90B1020 S76 R-NPF 45 Max. Line Current 0.85 UL Coil Wiring Dimensions Total Wt.Total Cap. Cap. Cap. Ign.Max. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig.Dist.(ft) A U1 1 0.9 2.15 2 - N/A D 2 35 120 V90B1020C S76 R-HPF 45 0.75 A U1 1 0.9 2.15 2 16/120 A7 Dry D 2 35 347 V90V1030 S76 HX-HPF 54 0.30 A X 3 0.7 2 4 4.5/280 B1 Oil D 3 35 120/240 V90E1030 S76 HX-HPF 54 0.80/0.40 D/C Z 3 0.67 2 4 4.5/280 B1 Oil D 3 50 120 V90B1120 S68 R-NPF 65 1.20 A U1 1 1.15 2.35 2 50 120 V90B1120C S68 R-HPF 65 1.00 A U1 1 1.15 2.35 2 22.5/120 A2 Dry D 2 - - N/A D 2 347 V90V1131 S68 HX-HPF 75 0.40 D X 3 0.8 2 4 6/330 A5 Dry D 2 50 120/240 V90E1131 S68 HX-HPF 76 1.20/0.60 F/F Z 3 0.8 2 4 6/330 A5 Dry D 2 • Architectural Lighting 50 120/240 V90E1151 S68 73 0.65/0.35 A/A V 3 1 2.25 5 17/340 B4 50 120/277 V90H1132 S68 HX-HPF 66 1.00/0.45 A Q1 3 1 2.4 3.6 70 120 V90B1222 S62 R-NPF 85 1.65 B U1 2 1.29 2.2 3 70 120 V90B1222C S62 R-HPF 85 1.25 B U1 2 1.29 2.2 3 28/120 A3 Dry D 2 70 600 V90Z1252 S62 0.15 A N 3 1.65 3.25 6 24/330 A2 Dry CWI CWI 96 - 2.95 4.6 7/280 Oil E 2 A1 Dry D 5 - N/A D 2 E 2 3 1.5 70 120/240 V90E1250 S62 CWI 83 0.75/0.40 A/A V 3 2.15 3.15 8 26/280 A2 Dry E 2 70 120/240 V90E1252 S62 CWI 96 0.85/0.40 A/A U 3 1.65 3.25 6 24/330 A2 Dry E 2 70 120/277/347 A5 Dry D 5 D/D/D A1 3 1.1 2.13 4 9/330 100 100 V90J1232 S62 HX-HPF 91 1.50/0.65/0.55 120 V90B1322 S54 R-NPF 118 2.15 E U1 3 1.5 2.4 3 120 V90B1322C S54 R-HPF 118 1.80 E U1 3 1.5 2.4 3 40/120 A3 Dry D 2 100 600 V90Z1352 S54 CWI 132 0.25 D N 3 2.15 3.15 8 35/280 A2 Dry E 5 100 120/208/240 V90C1353 S54 CWI 130 1.15/0.70/0.60 B/AA T 3 2.15 3.5 6.7 35/180 A2 Dry E 5 100 120/208/240/277 V90D1333 S54 HX-HPF 126 2.10/1.20/1.05/0.90A/A/A/A Y 3 2 100 120/240 100 120/277/347 150 150 V90E1350 S54 CWI 121 - A5 Dry D 2 - N/A D 2 3.45 5.9 10/280 A6 Dry D 5 1.10/0.55 A/A V 3 2.5 3.5 9 42/280 A3 Dry V90J1332 S54 HX-HPF 127 1.85/0.85/0.65 C/C/C A1 3 2.32 3.7 8 9/290 120 V90B1422 S55 R-NPF 166 3.20 E U1 2 2 2.95 4 120 V90B1422C S55 R-HPF 166 2.35 E U1 2 2 2.95 4 150 480 V90Y1454 S55 CWI 186 0.40 D N 3 3.15 4.55 11 51/180 A4 Dry E 3 150 120/208/240 V90C1454 S55 CWI 185 1.70/1.00/0.85 B/A/A T 3 3.15 4.6 9.5 51/180 A4 Dry E 5 150 120/208/240/277 V90D1435 S55 HX-HPF 188 2.80/1.60/1.40/1.25 D/B/C/C Y 3 2.5 3.8 7.4 14/280 A1 Dry D 5 3.95 3 2.5 347/120T V90V1454T S55 CWI 186 0.60 B A2 3 3.15 4.55 11 51/280 A4 Dry E 2 150 600/120T V90Z1454T S55 CWI 186 0.35 C A2 3 3.15 4.55 11 51/280 A4 Dry E 2 REACTOR 2 7/8 in Core HOLES CLEARED FOR # 6 BOLTS 1.88" (48 mm) 1.5" (38 mm) D/B/C A1 N/A D 2 120/277/347 2.25" (57mm) 3.15/1.30/1.10 - 52/120 A4 Dry D 2 150 1.88" (48mm) A B 2.625" (67mm) 2.188" (56 mm) 1.75" (45 mm) 8 13.5/290 A1 Dry D 2 3 3x4 Core HOLES CLEARED FOR # 6 BOLTS 2.189" (56mm) A B CWI/HX V90J1434 S55 HX-HPF 195 - E 2 A5 Dry D 2 150 1 3/4 in Core 3.94" (100mm) 2.44" (62 mm) HOLES CLEARED FOR #8 BOLTS 2.84" (72 mm) 3.50" (89 mm) Ballast Options 60 5/280 70 120/208/240/277 V90D1233 S62 HX-HPF 90 1.50/0.85/0.75/0.65 A/A/A/A Y REACTOR HPS Lamps and Ballasts 50 • Street Lighting Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #62 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com A B HPS Ballasts HIGH PRESSURE SODIUM LAMPS BALLASTS AND HIGH PRESSURE SODIUM BALLASTS 60Hz Watts 200 Input Voltage 347 200 120/240 Product ANSI Circuit Input No. Code Type Watts V90V1650 S66 CWI 241 Max. Line Current 0.75 V90E1650 S66 2.05/1.05 V 1 1.33 3 250 120/208/240/277 V90D1711 S50 CWA 295 2.50/1.45/1.25/1.10B/B/B/B E 1 1.8 3.6 250 120/240 V90E1750 S50 CWI 300 2.55/1.30 F/F V 1 1.65 3.75 12 28/330 A3 Dry 250 120/277/347 V90J1711 S50 CWA 295 2.70/1.15/0.95 B/A/B K 1 1.8 3.6 11 35/240 A2 Dry D 2 250 480/120T V90Y1711T S50 CWA 305 0.65 B S1 1 1.8 3.6 11 250 600/347 V90AS1750 S50 CWI 300 0.90/0.50 C/E Z1 1 1.65 3.75 12 28/330 A3 Dry CWA 460 3.80/2.20/1.90/1.70 C/C/D/C E 1 2.3 4.2 14 55/240 A4 Dry D 2 400 120/208/240/277 V90D1912 S51 CWI 241 UL Coil Wiring Dimensions Total Wt.Total Cap. Cap. Cap. Ign.Max. Rise Code Diag. Fig. A (in) B (in) (lbs) (µfd/Vmin) Fig. Type Fig.Dist.(ft) F N 1 1.33 3 10 22.5/330 A2 Dry E 2 D/D 10 22.5/330 A2 Dry 11 E 2 35/240 A2 Dry D 2 E 2 35/240 A2 Dry D 2 E 2 400 120/240 V90E1950 S51 CWI 470 4.05/2.05 F/F V 1 2.45 4.1 16 45/330 A4 Dry 400 120/277/347 V90J1911 S51 CWA 460 3.80/1.70/1.30 C/C/D K 1 2.3 4.2 14 55/240 A4 Dry D 2 400 208/120T V90P1950T S51 CWI 470 2.35 D A2 1 2.45 4.1 16 45/330 A4 Dry E 2 400 600/347 V90AS1950 S50 CWI 450 1.40/0.80 D/H Z1 1 2.45 4.3 12 45/270 A4 Dry E 2 400 480/120T V90Y1912T S51 CWA 464 1.00 C S1 1 2.6 4.45 15 430 120/208/240 4.55/2.65/2.25 B/B/A 55/240 A4 Dry D 2 T 1 2.6 4.5 15.7 45/260 A4 Dry 600 120/208/277/480 V90D2111 S106 CWA 695 5.90/3.40/2.95/2.55A/A/A/A Y1 2 3.4 5.4 24.5 59/300 A14 Dry 1000 N 2 5.5 7.25 40 22/660 B15 Oil F 2 1000 120/208/240/277 V90D2310 S52 CWA 1065 8.95/5.00/4.50/3.90 C/C/C/C E 2 3.8 5.9 27.5 26/480 B12 Oil F 5 1000 120/208/240/277 V90D2311 S52 CWA 1100 9.50/5.50/4.75/4.20 C/B/C/C E 2 3.75 5.9 26/525 B12 Oil F 5 1000 120/208/240/277 V90D2315 S52 CWA 1065 9.25/5.15/4.75/4.05 C/C/C/C E 2 3.8 5.9 25.5 26/480 B12 Oil F 5 1000 V90E2353 S52 CWI 1095 9.50/4.75 A/C V 2 5.5 7.25 40 1000 120/277/347 V90J2310 S52 CWA 1065 8.95/3.90/3.15 E/E/E K 2 3.8 1000 V90Y2311T S52 CWA 1100 2.30 C S1 2 3.9 120/240 480/120T V90Z2353 S52 4.75" (121 mm) 3.87" (98 mm) 1.90 A 27 E 2 15 22/660 B15 Oil F 2 26/480 B12 Oil F 5 5.9 28.8 26/525 B12 Oil F 2 6 28 2 4x6 Core HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 4.37" (111 mm) A B 6.00" (152 mm) HOLES CLEARED FOR #10 BOLTS 4.25" (108 mm) 3.87" (98 mm) 4.375" (111 mm) 5.375"(136 mm) HPS Lamps and Ballasts CWA/CWI 1 4x4 Core CWI 1095 CWA/CWI 600 V90C2050 S145 CWI 492 E 2 A B Ballast Options Add Suffix for Options: C - With Capacitor (Standard) K - With Capacitor and Bracket Kit B - With Welded Bracket, No Cap Ballast Bracket and Kit Figures are located on Page #69 Capacitor and Ignitor Figures are located on Page #68 Wiring Diagrams are located on Page #62 61 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com HPS Ballasts HIGH PRESSURE SODIUM LAMPS AND BALLASTS Wiring Diagrams HPS Lamps and Ballasts Wiring diagrams for all HIDirect’s HPS ballast products are provided on this page. The ballast data tables indicate the reference letter corresponding to the correct diagram for each ballast product. Refer to the table for the required ballast before referencing any diagram. The wiring diagram is the blueprint for the ballast circuitry, including the input supply voltage and grounding methods. A ground connection must be made to all ballasts to avoid shock hazard, personal injury or damage to the luminaire or installation. Ballast installations and groundings should be made in accordance with all applicable government codes and regulations where required. E K N T U V X Y Z A1 Q1 S1 U1 Y1 Z1 A2 62 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Reference Guide TECHNICAL INFORMATION Introduction In order to bring the best quality and service in the HID lighting industry, we have included in this catalog a reference guide containing a trouble shooting guide, a lamp and ballast cross reference and also a glossary of terms. We hope this information is helpful and will be used often. When you think of metal halide lamps and ballasts, think of HIDirect. Trouble Shooting Guide . . .p 64-65 Replacement Parts . . . . . . . . . .p 66-67 Capacitors Figures . . . . . . . . . . . .p 68 Ignitor Figures . . . . . . . . . . . . . . . . . .p 68 Lamp Shapes and Bases . . . .p 68 Ballast Brackets . . . . . . . . . . . . . . . .p 69 Glossary of Terms . . . . . . . . . .p 70-71 Lamp Cross Reference . . . . .p 72-73 Ballast Cross Reference . . . . . .p 74 Reference Guide Reference 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 63 Trouble Shooting Guide TECHNICAL INFORMATION #1 How can I distinguish between lamp failure and fixture failure? All HIDirect fixtures shipped from our facility are tested to operate a compatible lamp. First check to see that you have the correct wattage lamp that matches the ballasts. The label affixed to the side of the fixture identifies the wattage of that specific fixture and the coordinating lamp and ballast ANSI Codes. If the lamp does not ignite, replace with a known good lamp. If that lamp does not operate there may be a wiring or ballast problem. #2 What do I need to check within the system prior to operation? Be certain that the lamp you are using is compatible with the fixture wattage and ANSI code. #3 What are the dimming wires that come out of an electronic fixture? Dimming wires from the fixture are Orange and Brown. Please follow the instructions exactly for correct wiring. If a motion sensor is used, please follow the wiring diagrams provided by the sensor manufacturer. The cord coming from the fixture is already wired to the inside of the ballast and is ready to be utilized. If a rework of the cord connection for length extension or compatibility with a specific plug is required, a re-wiring of the new cord is necessary. Note that the Pink (light red color) wires are for the lamp connection (which is already connected to the socket). The Green wire is the ground wire, Yellow is the low or neutral wire, and the Black is the high or hot wire. All of these wires are integrated into our own cord; be certain that you are connecting the plug correctly to the fixture’s cord. In the case of the use of a longer cord, please follow the standard wiring diagrams approved by the lighting industry. #4 Reference Guide What if the lamp will not start? 1) Check to see if lamp is loose in the socket. Check for arcing (blackening) at the center contact button and retighten lamp until it is properly seated. Tightening too much may cause lamp breakage. 2) No power to ballast: Check circuit breakers or other causes of potential power outages. 3) Normal end of lamp life: Test operating lamp in adjacent luminaire. Replace if necessary. 4) Sensing devices: Replace sensing device as needed. 64 5) Defective/improper wiring: Verify fixture has been properly wired. Correct as needed. Correct wiring if required. 6) Voltage at luminaire is too low: Line voltage at input of ballast should be within 10% of label rating (increased loading/demand decreases available voltage at ballast primary). Check at full load. If tapped ballast, match ballast tap connection to supply voltage measured at ballast. Verify that lamp to ballast distance is acceptable. 7) Ballast/Lamp: Use a ballast compatible with your lamp. Ensure ballast and lamp are not defective. 8) Improper lamp operating position: Be certain operating position agrees with lamp specifications. 9) Hot restrike: When power is cut or interrupted for HID lamps, they require a cool-down period of up to 20 minutes for “hot restrike” with standard probe start metal halide systems and 8-12 minutes with Uni-Form® pulse start systems. Verify ignitor pulse is present. #5 What if the lamp life is reduced? 1) Lamp compatibility: Check that the lamp is the correct wattage and ANSI Code. 2) Lamp damaged: Visually check interior and exterior bulb, arc tube and base for defects. 3) Ballast: Make certain that the ballast label agrees with the line voltage and lamp. 4) Lamp in incorrect position: Replace incorrect lamp with suitable lamp in proper position. #6 What if lamp flickers or cycles? 1) Check the photocell (if applicable): If a photocell is used to switch the fixture, cover the photocell window or eye completely with black electrical tape and check for proper operation. A. If the cycling STOPS, re-aim the photocell (or the fixture) to reduce fixture light spill onto the photocell eye. B. If the cycling CONTINUES, replace the photocell with a shortening cap if available or bypass the photocell completely in the circuit temporarily. If the lamp remains on the photocell is defective. If the cycling STILL CONTINUES, the lamp is probably bad. 2) Wrong ballast: New lamps may “cycle.” If lamp doesn’t stabilize after 3 starts or after 30-60 sec. intervals, check ballast. Measure lamp operating voltage. Measure ballast open circuit voltage. Replace as necessary. 3) Variable voltage: Other machinery on lighting circuits may cause flickering. Remove lighting circuits from those serving these devices. Provide voltage regulators. 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Trouble Shooting Guide TECHNICAL INFORMATION #7 #11 1) Hard starter: If lamp doesn’t ignite rapidly, check voltage and ballast. Replace if necessary. 1) Normal maintenance: Color shift may occur as lamps age. Using Uni-Form® pulse start systems and/or group re-lamping will minimize this. What if the lamp starts slowly? #8 What if the fuses are blown or circuit breakers are open on lamp start? What if a difference in lamp color is noted? 2) Wrong lamp color: Etching on lamps will be different if lamps are not the same. Replace as needed. 1) Overloaded circuit: Rewire to accommodate starting open circuit current of lamp and ballast found on lamp specification sheet. 3) Variations in luminaires: Variations in the surface or finish of the reflectors and/or lenses can introduce color differences. Interchange lamps to check for possible luminaire differences. Make certain that luminaries are clean. 2) High momentary transient current: Limit amperage by reducing luminaire quantity to each circuit. 4) Environmental variations: A room’s walls, floors, furnishings, etc. may affect appearance of lamp color. #9 Measure capacitance to specification using capacitance meter. Replace capacitors if needed. What if the lamp output light is low? 1) Lamp depreciation: Refer to published technical characteristics to see if depreciation is within normal range. The lighting system may be due for a group relamp. 2) Incorrect voltage: Check if rating designation conforms to lamp rating description. Check line voltage at ballast and compare to rated voltage requirements. Look at wiring connections for voltage loss points. Check socket contact point. 3) Incorrect ballast output: Determine if it conforms to lamp requirements. If voltage & current don’t stabilize within 5-10 min. of warm-up time, ballast output is incorrect & adjustment should be made. #12 What if the reflector has changed shape and color? Verify the reflector meets the following guidelines: Plastic: Any open optic greater than a 22 inch diameter and 3570 cubic inch volume. Glass and Metal: Any open optic greater than a 15 inch diameter and 1390 cubic inch volume: Optics specifications are UL requirements based on heat constraints. Optics may also be referred to as a Reflector, Reflexor, Refractor etc. by various manufacturers. All of HIDirect’s fixtures are “Open Rated” only. 4) Dirt accumulation: Regularly clean and maintain your lamp and luminaire. #10 What if the arc tube becomes blackened or swollen? 1) Over-wattage operation/improper ballasting: Check if lamp is operated on ballast designed for higher wattages, check ballast label against lamp specification. Reference Guide 2) Reflector problem: If you suspect reflector is refocusing damaging energy on arc tube, contact luminaire manufacturer. 3) “Glow state” operation: Under certain conditions, lamps will go into a partial discharge (dim glow). Replace lamp and check ballast. 65 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Replacement Parts TECHNICAL INFORMATION Lamp Sockets 4KV Rated Product No. Fix. Req. Socket Size Socket Lead Color Length CE001X01R0 Enclosed Mogul E39 White 12 All enclosed rated (ANSI Type-E) mogul based MH and MS lamps excluding POMB horiz. lamps CE001X03R0 POMB Mogul EP39 Yellow 12 Only MS/HOR enclosed rated (ANSI Type-E) mogul based lamps (e.g. MS 400W/HOR) CE001X04R0 Open Mogul EX39 Pink 12 Accepts only open rated (ANSI Type-O) MP, MPI and MPSE mogul based lamps (e.g. MP 400W/V/PS/740 or MPI 360W/BU/EM) CE002X04R0 Enclosed Medium E26 White 9 All enclosed rated (ANSI Type-E) medium based MH and MS lamps CE002X04R0 Open Medium EX26 White 12 Only open rated (ANSI Type-O) medium based lamps About Open Rated Lamps and Sockets Description Open Fixture Open Rated Lamps Open fixtures offer significant advantages over enclosed fixtures. They do not require cover lenses which reduce light output and accumulate dirt. Enclosed fixtures make lamp replacements more difficult. For safety, open fixtures need open rated (ANSI Type-O) metal halide lamps. To reduce the risk of liability, lighting specifiers need to be aware of the criteria for a true open rating and what the Type-S or Type-O designations indicate about lamp construction. HIDirect’s Type-O open fixture rated lamps characteristics: 1. Shroud around the arc tube, which helps prevent damage to the outer bulb in the event of an arc tube rupture Enclosed Fixture EX26 Socket Medium Base The narrower EDX17 neck allows full insertion into the socket. The wider bulb neck will not fit past ceramic neck of socket. Mogul Base The standard center contact won’t reach the contact in the dedicated socket. The extended center contact completes the circuit in the socket. EX39 Socket 2. Open fixture rated base, such as an EX39 mogul base or narrow neck bulb with a medium base 3. Pass the ANSI C78.389 lamp containment test, where arc tubes are forcibly ruptured and must be contained within the outer jacket. All of HIDirect’s MP, MPSE and MPI lamps meet the requirements to be rated Type-O, and can be used with confidence. Reference Guide Open Rated Lamp Benefits Type-O EX39 Base Arc Tube Shroud HIDirect’s MP, MPSE and MPI lamps: • Meet requirements of the 2005 NEC • Meet ANSI criteria for use in open luminaires • No luminaire lens required, delivering more light Lumen loss with a lens is up to 16% • Can be operated continuously, no shut-off required • Operate in open or enclosed luminaires • More cost effective than installing a fixture lens 66 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Replacement Parts TECHNICAL INFORMATION A full range of HID oil filled and dry film capacitors and ignitors are available. Call HIDirect customer service for pricing and availability. Replacement Capacitors continued Replacement Ignitors ACG188 ACG189 ACG200 ACG247 ACG257 ACG263 ACG302 ACG311 ACG312 ACG313 ACG322 ACG324 ACG325 ACG326 ACG004 ACG005 ACG033 ACG160 ACG172 ACG181 ACG206 ACG213 ACG222 ACG226 ACG240 ACG255 ACG258 ACG264 ACG277 ACG279 ACG300 ACG301 ACG303 ACG305 ACG306 ACG307 ACG308 ACG309 ACG310 ACG314 ACG320 ACG321 ACH277 ACH279 Ignitor Part # BVS004AREPL BVS005REPL BVS005AREPL BVS006REPL BVS006AREPL BVS012REPL BVS016REPL BVS020REPL BVS031REPL BVS032REPL BVS040REPL BVS041REPL BVS042REPL BVS045REPL Replacement Capacitors Capacitor Number ACB046OV ACB070OV ACB079OV ACB109OV ACB111OV ACB115OV ACB151OV ACB159OV ACB170OV ACB198OV ACB201OV ACB214OV (2) ACB215OV ACB220OV ACB224OV ACB228OV ACB232OV ACB237OV ACB247OV ACB256OV ACB264OV ACB265OV ACB266OV ACB274OV ACB276OV ACB277OV ACB278OV ACB279OV ACB282OV ACB286OV ACB287OV ACB288OV ACB292OV ACB327OV ACG148 ACG149 ACG164 ACG183 Description Capacitance (Micro-Farads) VAC Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Oil Cap Dry Film Dry Film Dry Film Dry Film 4.5 7.5 7 10.5 9 9 10 17 12 11 16 (2x16) 32 24 24 22 19.5 21 15 24 32 26 21 44 22 28 15 26 10 18 18 25 33 32 22 31.2 15.6 8.7 11 660 540 660 520 520 660 400 370 480 660 370 660 660 480 480 520 520 660 400 525 525 410 520 660 480 400 400 400 480 525 400 240 525 525 330 330 330 330 Capacitor Number Description Capacitance (Micro-Farads) VAC Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film Dry Film 19 14.5 21.5 24 42 30 52 36 38 15 8 52 59 21 40 52 6 13.5 35 22.5 28 24 45 7 51 55 9 26 15 10 18 16 12.5 20 22 13 10 14 8 5 32 12 15 10 330 330 330 400 280 280 330 280 330 280 330 330 330 400 280 280 330 330 280 330 330 330 330 330 280 300 330 330 400 400 330 330 330 330 330 330 330 330 280 280 330 330 400 400 Ignitors Oil-filled capacitor Dry-film capacitor CAPACITOR NOTES 1. See "INCLUDED CAPACITOR" column in ballast list for correct capacitor replacement 2. Two capacitors required for V90AA6910C and V90AA6910K (32 Micro-farads) Reference Guide 67 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Capacitors and Ignitors TECHNICAL INFORMATION C IGNITOR– OVAL DIA 1.97 1.62 1.97 1.97 1.62 1.97 1.62 1.97 1.97 2.03 2.03 1.97 1.97 2.03 2.03 2.03 1.62 WD 2.97 2.75 2.97 2.97 2.75 2.97 2.75 2.97 2.97 3.72 3.72 2.97 2.97 3.72 3.72 3.72 1.32" (33.5 mm) 1.25 in 2.25 in .605 .250 .200 YELLOW .930 1.250 END VIEW 2.16" (55 mm) F IGNITOR– OVAL IGNITOR– OVAL G 2.06" (52.3mm) IGNITOR- BVS-046 H 2.06" (52.3mm) 2 in 2.45" (62.2mm) 2 in 3 in 2.30" (58.4mm) 2.30" (58.4mm) 1.48" (37.6mm) 1.16" (29.5mm) Lamp Shapes and Bases Lamps MBIL S Double Ended MH-DE Double Ended G12 Bi Pin T12 Tubular ED17 Elliptical Dimpled T15 Tubular EDX17 Narrow Neck (open fixture) ED28 Elliptical Dimpled T25 Tubular ED37 Elliptical Dimpled BT37 Blown Tubular Reference Guide BT56 Blown Tubular Bases Bi Pin Ceramic Base (G12) RSC Recessed Single Contact (R7s and RX7s) Fc2 Ceramic 3.610 2.75 1.48" (37.6mm) B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 (Inches) POLARIZED QUICK DISCONECT 2.315 1.750 1.16" (29.5mm) HT 3.00 3.25 3.68 3.37 3.87 4.00 3.37 2.87 4.00 4.94 6.00 4.37 3.87 4.44 4.37 4.37 3.00 WHITE/RED 0.25" (6.3 mm) WD 1.38 1.60 1.75 1.75 1.38 1.49 1.49 1.97 1.38 1.49 1.80 1.75 IGNITOR– ROUND .132 3.50 (88.9mm) HT 3.93 3.93 3.93 4.88 2.73 2.73 3.93 4.88 2.93 4.88 3.69 4.60 E 2.610 OVAL DIA. WIDTH (Inches) A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A13 A14 4.75"(121mm) 4.25" (108 mm) HEIGHT WIDTH IGNITOR– ROUND 1.00" (25.4 mm) 0.58" (15 mm) HEIGHT D BLUE CAPACITOR– OIL FILLED B 3.00"(76mm) CAPACITOR– DR Y FILM TOP VIEW A MED Medium Base (E26) MOG Mogul Base (E39) Open Fixture Mogul Base (EX39) POMB Position Oriented Mogul Base (EP39) 68 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Ballast Brackets TECHNICAL INFORMATION Core & Coil Welded Brackets These brackets are supplied as an option by adding a “B” suffix to the ballast product number 1500-2000W 4 x 6 Core T&L Small Core E&I Reactors (3/4, 7/8, and 1 in) A B .28" .75" 1.51" 4.50" .31" 1.51" 3.19" 4" 6.75" 7.75" 4 x 4, 4 x 6 Core T&L 3.75 x 4.5 Core E&I Reactors 2x400W-1000W 4 x 6 Core T&L 3 x 4 Core T&L C D .28" 1.25" E .28" 1" 5.38" 3.98" 6.50" 5.10" 2.75" .88" .28" .88" 6.63" 7.75" Core & Coil Adjustable Mounting Brackets (Included with Capacitor and Bracket Kits) These brackets, along with appropriate hardware, are supplied as an option by adding a “K” suffix to the ballast product number 3 x 4 Core T&L Small Core E&I Reactors (3/4, 7/8, and 1”) F 4 x 4, 4 x 6 Core T&L 3.75 x 4.5 Core E&I Reactors G .31" 1.19" 1.33" .28" 4.25" 5.75" 5.50" 7.25" Core & Coil Adapter Mounting Bracket Kits These brackets along with appropriate hardware are available in kits H BCK-016 To mount 1” Core E&I Reactors in fixtures with a 3 x 4 T&L footprint 3.94" 3.5" I 4.75" 4.38" BCK-017 To mount 3.75 x 4.5 Core E&I Reactors in fixtures with a 4 x 6 T&L footprint Reference Guide BCK-015 To mount 3.75 x 4.5 Core E&I Reactors in fixtures with a 4 x 4 T&L footprint 6" 5.38" J .653" 4.21" 3.75" 3.84" 2.5" 2.44" 4.21" 3.84" 3.84" 3" 4.50" 69 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Glossary of Terms TECHNICAL INFORMATION Arc Tube: A completely sealed quartz or ceramic tube where the electrical discharge (arc) occurs and light is generated Ballast: A device that, by means of resistance, inductance, capacitance or electronic elements, singly or in combination, controls the current, voltage and waveform to the required values for proper lamp starting and operation Ballast Characteristic Curve: The curve of lamp wattage vs. lamp voltage over a range of normal lamp voltages when an HID ballast is operated at a given supply voltage Formed Body Arc Tube: Precisely reproducible ellipsoidal arc tube formed by pressurizing molten quartz inside a mold; produces consistent arc tubes with higher efficacy and improved color uniformity HID: High Intensity Discharge lamps; includes metal halide, mercury vapor and high pressure sodium High-Power-Factor (HPF) Ballast: A ballast designed so that the input power factor is not less than 90% when the ballast is operated at the rated supply voltage using an appropriate reference lamp BTL : The distance from ballast-to-lamp High Reactance Autotransformer (HX) Ballast: An autotransformer lag circuit that uses a magnetic shunt path between primary and secondary coils to control reactance; has operating characteristics similar to those of a reactor and has input taps to accept a wide range of supply voltages Burning Position: The position or orientation in which a lamp operates Hot Restart or Restrike Time: The time from lamp extinction to lamp re-start after a supply voltage interruption Cold Start Time: The amount of time from the application of ballast voltage to ignition of the arc discharge Ignitor: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical pulses to start a discharge lamp Ballast Power Factor: Power consumed by the lamp and ballast (watts) divided by the product of line voltage and line current (“volt-amps” or “VA”); A measure of power quality and of concern to utilities Color Rendering Index (CRI or Ra): A measure of a light source’s ability to render colors relative to a standard of 100 Constant Wattage Autotransformer (CWA) Ballast: A magnetic autotransformer lead ballast circuit incorporating a capacitor in series with the lamp; compared to other ballasts, the CWA regulates over a wider input voltage range, holding lamp current nearly constant Constant Wattage Isolated (CWI) Ballast: A magnetic lead ballast circuit incorporating a fully-isolated secondary winding; it has a capacitor in series with the lamp and the same performance features as the CWA ballast Correlated Color Temperature (CCT): The perceived “color” of the light emitted by a lamp expressed in kelvin (K) units Current Crest Factor: The ratio of the peak-to-RMS value of lamp current; metal halide magnetic ballast values range from 1.5 to 1.8 e-Lamp®: 4000K color temperature pulse start lamps specifically designed for use on high frequency electronic ballasts; capable of dimming down to 35% lamp power Economic Life: The number of hours a group of lamps will burn before it is economically and aesthetically advisable to group relamp (typically 60% to 75% of rated life) Efficacy (Lamp): A ratio of lamp lumens to lamp power measured in lumens per watt (LPW) Reference Guide Fixture Requirements: Enclosed or open types Energy Master®: HIDirect’s line of energy-saving retrofit lamps that operate on existing ballasts at lower wattages than the original lamps Extinction Voltage: The RMS value of supply voltage at which a reference lamp extinguishes when the supply voltage is slowly reduced from its rated value. The ANSI procedure calls for a 2 to 3% reduction in supply voltage per second Initial Lumens: The light output of a lamp at rated power on a reference ballast after 100 hours of operation Input Power: See System Power Lag Ballast: A magnetic ballast having a lagging lamp current with respect to the supply voltage. Current limiting is primarily inductive; holds lamp power reasonably constant with respect to lamp voltage variations Lamp Power Factor: Power consumed by the lamp divided by the product of RMS lamp voltage and RMS lamp current; it is less than unity on magnetic ballasts operating at 50 or 60 hz Lamp Voltage: The RMS voltage of a fully warmed-up lamp Lamp Power: The power consumed by a lamp after warm-up, measured in watts Lamp Regulation: The ratio of lamp power to lamp voltage, often expressed in graphical format Lead Ballast: A magnetic ballast having a leading lamp current with respect to the supply voltage; current limiting is accomplished by means of an inductor as well as a capacitor connected in series with the lamp; this includes CWA and CWI ballasts Light Center Length (LCL): The distance from the center of the visible arc discharge to the bottom contact of the base Line Regulation: The ratio of lamp power to ballast input voltage often expressed as a percentage Lumens: A measurement of light; takes into account the human eye sensitivity curve so that more weight is given to the yellow-green part of the light spectrum (photopic) Lumen Maintenance: The lumen output of a lamp at a given operating time or a percentage of 100 hour lumens at that time Lumens Per Watt (LPW): See Efficacy Maximum Overall Length (MOL): The maximum allowable distance from the top of the glass bulb to the end contact of the base Continued on next page 70 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Glossary of Terms TECHNICAL INFORMATION Mean Lumens: Light output at 40% of rated lamp life Natural White®: Line of pulse start lamps that have 5000K color temperature, 90+ CRI and 90% lumen maintenance Normal (Low) Power-Factor (NPF) Ballast: A ballast designed so that the input power factor is less than 90% when the ballast is operated at the rated supply voltage using a reference lamp Open Circuit Current (Line): The RMS current measured at the input terminals of a ballast with lamp removed or inoperative Open Circuit Voltage, Ballast (OCV): The voltage across the output terminals of a ballast when no load is connected (RMS, unless otherwise stated) Operating Current (Line): The RMS current measured at the input terminals of a ballast which is operating a reference lamp Operating Voltage: See Lamp Voltage Opti-Wave® Ballast: A lag (magnetic) ballast designed with a low current crest factor for improved lamp performance. Opti-Wave lag ballasts are also optimized for low open circuit current Peak Lead Ballast: A CWA ballast that produces a highly peaked open circuit voltage wave shape and a peaked current wave shape Photopic Light: Applicable during normal daytime lighting conditions; describes lumen values measured using the high luminance eye sensitivity function centered at 555 nm (yellow-green). See page 18 Position Oriented Mogul Base (POMB): Used with horizontal operated probe start lamps; has an alignment pin in the base for proper lamp orientation when installed into an EP39 socket Power Factor (Ballast): The ratio of the ballast input power (watts) divided by the product of the RMS ballast supply voltage and ballast supply current Probe Start Lamp: A metal halide lamp which uses a starter electrode (probe) to assist in starting without the use of an ignitor pulse; also contains a bimetal switch and resistor Pulse Start CWA Ballast: A CWA ballast using an ignitor to start the lamp Pulse Start Lamp: Specially designed metal halide lamp that requires a high voltage pulse for starting; has no starter electrode (probe) and has high starting gas pressure Quad-tap Ballast: A magnetic lag ballast with input voltage taps for four standard voltages - 120, 208, 240 and 277 volts Rated Supply Voltage: The input voltage for which a ballast is designed to operate, and to which performance characteristics are referred Reactor Ballast: A lag ballast with a single input voltage tap Regulated Lag Ballast: A lag ballast with a third coil for improved lamp power regulation Restrike: To re-ignite the arc of an HID lamp RMS: root-mean-square S/P Ratio: The ratio of scotopic lumens to photopic lumens. See page 18 Short-Circuit Current (Ballast): The current at the output terminals of a ballast when the output is shorted (RMS, unless otherwise stated) Shroud: A quartz cylinder surrounding the arc tube of a open-rated (ANSI Type-O) metal halide lamp; designed to reduce the damage to the outer bulb if an arc tube rupture occurs; required to pass the ANSI Type-O containment test Spectral Power Distribution: The distribution of radiant power (watts) of a lamp as a function of wavelength (nm) Starter: See Ignitor Starting Current (Line): The RMS current measured through the input terminals of a ballast 5 to 15 seconds after a lamp has started Starting Pulse: A high-voltage, low-energy pulse superimposed on the open circuit voltage of some HID ballasts to aid in starting a lamp Sustaining Voltage: The instantaneous voltage available to the lamp from the ballast at the time the lamp current passes through zero System Power: The power measured at the input terminals of a ballast while operating a reference lamp Tipless Arc Tube: An arc tube made without an auxiliary exhaust tube for dosing gases and other ingredients Type-E Lamps (Enclosed Rated Lamps): Lamps that must be used in enclosed luminaires which meet the requirements of UL1598. Type-S Lamps: Lamps that do not contain a shroud around the arc tube yet are considered “suitable” for open luminaire operation, only if operated in the vertical ±15° position; do not meet ANSI criteria for containment and must be turned off at least once per week for a minimum of 15 minutes if operated continuously; These lamps must be replaced at or before reaching rated lamp life; not recommended by the NEC. Type-O Lamps (Open Rated Lamps): Lamps that can be operated in either open or enclosed luminaires and do not need weekly shut-off; meet the ANSI criteria for containment-rated operation; special exclusionary sockets are available for these lamps to ensure that the wrong lamp type is not used. See page 66 Uni-Form®: HIDirect’s pulse start lamp and ballast systems that contain a formed body arc tube; requires a high voltage pulse for starting; has improved lumen maintenance Reference Guide Rated Life: The number of operating hours at which 50% of most metal halide lamps, or 70% to 80% for some Uni-Form® pulse start lamps, initially installed will still be operating Scotopic Light: Applicable during dark nighttime lighting conditions; describes lumen values measured using the low luminance eye sensitivity function centered at 507 nm (blue-green). See page 18 Ventronic™ ballast: HIDirect’s high frequency electronic pulse start ballasts Warm-Up Time: The amount of time from ignition of the lamp to 90% of full light output Watts: A measure of energy (in joules) being used or emitted each second White-Lux®: HIDirect’s line of retrofit metal halide lamps that operate on high pressure sodium ballasts UL “Temp code”: An Underwriters Laboratories (UL) alphabetic temperature code for ballasts which designates a range of temperature rise of wire over ambient temperature. The code is found on the label directly following the number 1029X, where X is the appropriate alphabetic character 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com 71 Lamp Cross-Reference TECHNICAL INFORMATION Lamp Description Product ANSI Number Code Philips Osram/ Sylvania GE Uni-Form Pulse Start Lamps ® Reference Guide 50 WATT MP 50W/U/UVS/PS/3K 10226 M110/O MP50/U/MED MXR50/U/MED/O MP 50W/C/U/UVS/PS/3K 10381 M110/O MP50/C/U/MED MXR50/C/U/MED/O MP 50W/C/U/UVS/PS 30041 M110/O MP 50W/U/UVS/PS 32100 M110/O MH 50W/U/PS 52312 M110/E MXR50/U/MED MH 50W/C/U/PS 13093 M110/E MXR50/C/U/MED 70 WATT MP 70W/U/UVS/PS 40389 M98/O MP70/U/MED MP 70W/U/UVS/PS/3K 45424 M98/O MXR70/U/MED/O MP 70W/C/U/UVS/PS 67115 M98/O MP70/C/U/MED MP 70W/C/U/UVS/PS/3K 14611 M98/O MXR70/C/U/MED/O MP 70W/C/U/ED28/UVS/PS/3K 22466 M98/O MH 70W/U/PS 78138 M98/E MVR70/U/MED MH 70W/U/ED28/PS 16017 M98/E MH 70W/C/U/PS 12180 M98/E MVR70/C/U/MED 100 WATT MP 100W/U/UVS/PS 96267 M90/O MP100/U/MED MP 100W/U/UVS/PS/3K 96770 M90/O MXR100/U/MED/O MP 100W/C/U/UVS/PS 11278 M90/O MP100/C/U/MED MP 100W/C/U/UVS/PS/3K 11245 M90/O MXR100/C/U/MED/O MP 100W/C/U/ED28/UVS/PS/3K 22145 M90/O MH 100W/U/PS 27266 M90/E MVR100/U/MED MH 100W/U/ED28/PS 67868 M90/E MH 100W/C/U/PS 15823 M90/E MVR100/C/U/MED MH 100W/C/U/ED28/PS 79986 M90/E 125 WATT MP 125W/BU/UVS/PS 13341 M150/O MP 125W/V/ED28/UVS/PS 25813 M150/O MP 125W/C/BU/UVS/PS 43319 M150/O MH 125W/HBU/PS 76602 M150/E MH 125W/HBU/ED28/PS 61914 M150/E MH 125W/C/HBU/PS 35638 M150/E 150 WATT MP 150W/U/UVS/PS/740 22455 M102/O MP150/U/MED MP 150W/U/ED28/UVS/PS/740 58963 M102/O MP 150W/U/UVS/PS/732 22522 M102/O MXR150/U/MED/O MP 150W/C/U/UVS/PS/737 22888 M102/O MP150/C/U/MED MP 150W/C/U/ED28/UVS/PS/737 32147 M102/O MP 150W/C/U/UVS/PS/732 80039 M102/O MXR150/C/U/MED/O MH 150W/U/PS/740 99584 M102/E MVR150/U/MED MH 150W/U/ED28/PS/740 13556 M102/E MH 150W/C/U/PS/737 94986 M102/E MVR150/C/U/MED MH 150W/C/U/ED28/PS/737 21344 M102/E 175 WATT MP 175W/BU/UVS/PS/740 69854 M137/M152/O MS 175W/BU/PS/740 68475 M137/M152/E MS175/BU/PS MS175/PS/BU-ONLY MVR175/VBU/PA MS 175W/BU/MED/PS/740 16497 M137/M152/E MS175/PS/BU-ONLY/MED MVR175/VBU/MED/PA MS 175W/C/BU/PS/737 68246 M137/M152/E MS175/C/BU/PS MS175/C/PS/BU-ONLY MVR175/C/VBU/PA MS 175W/C/BU/MED/PS/737 34691 M137/M152/E MS175/C/PS/BU-ONLY/MED MVR175/C/VBU/MED/PA 200 WATT MP 200W/V/UVS/PS/740 22147 M136/O MP 200W/C/V/UVS/PS/737 59174 M136/O MP 200W/C/V/UVS/PS/732 44872 M136/O MS 200W/V/PS/740 57739 M136/E MS200/PS/BU-ONLY/BT28 MS 200W/BU/MED/PS/740 60811 M136/E MS 200W/C/V/PS/737 70345 M136/E MS200/C/PS/BU-ONLY/BT28 MS 200W/C/BU/MED/PS/737 60812 M136/E MS 200W/H75/T15/PS/740 70764 M136/E 250 WATT MP 250W/BU/UVS/PS/740 64658 M138/M153/O MP250/PS/BU-ONLY MP 250W/C/BU/UVS/PS/737 32658 M138/M153/O MP250/C/PS/BU-ONLY MP 250W/BU/UVS/PS/EM/950 19523 M138/M153/O CDM250/V/O/PS/4K ALTO MCP250/PS/BU-ONLY/940 PB CMH250/V/PA/O MPSE 250W/BU/UVS/950 95047 M___/O MS 250W/V/PS/740 49621 M138/M153/E MS250/BU/PS MS250/PS/BU-ONLY MVR250/VBU/PA MS 250W/H75/PS/740 81054 M138/M153/E MS250/HOR/PS M250/PS/U MVR250/HOR/PA MS 250W/C/V/PS/737 81365 M138/M153/E MS250/C/BU/PS MS250/C/PS/BU-ONLY MVR250/C/VBU/PA MS 250W/H75/T15/PS/740 57625 M138/M153/E - Lamp Description Product ANSI Number Code Philips Osram/ Sylvania GE 320 WATT MP 320W/BU/ED37/UVS/PS/740 21714 M132/M154/O MP320/BU/PS MPR320/VBU/XHO/PA MP 320W/V/EL/ED37/UVS/PS/740 25984 M___/O MP 320W/BU/ED28/UVS/PS/740 10103 M132/M154/O MP320/350/PS/BU-ONLY/BT28 MP 320W/C/BU/ED28/UVS/PS/737 10104 M132/M154/O MP320/350/C/PS/BU-ONLY/BT28 MPR320/C/PA/ED28 MP 320W/C/BU/ED37/UVS/PS/737 32795 M132/M154/O MP320/C/BU/PS MPR320/C/VBU/XHO/PA MP 320W/C/BU/ED37/UVS/PS/732 66506 M132/M154/O MP 320W/C/V/EL/ED37/UVS/PS/737 32409 M___/O MP 320W/BU/ED37/UVS/PS/EM/950 98520 M154/O CDM320/O/PS/4K/ALTO MCP320/PS/BU-ONLY/840/BT37 PB CMH320/V/PA/O MP 320W/BU/ED28/UVS/PS/EM/950 98530 M154/O MPSE 320W/BU/ED37/UVS/950 28712 M___/O MPSE 320W/C/BU/ED37/UVS/950 35698 M___/O MS 320W/V/ED37/PS/740 52236 M132/M154/E MS 320W/V/ED28/PS/740 59194 M132/M154/E MS320/U/PS MS320/PS/BU-HOR MVR320/VBU/XHO/PA MS 320W/H75/ED28/PS/740 47549 M132/M154/E MS320/PS/BU-HOR MVR320/HOR/ED28/PA MS 320W/H75/T15/L/PS/740 79710 M132/M154/E MS 320W/C/V/ED28/PS/737 77594 M132/M154/E MS320/C/U/PS MS320/C/PS/BU-HOR MVR320/C/VBU/XHO/PA MS 320W/C/V/ED37/PS/737 67712 M132/M154/E MS 320W/C/H75/ED28/PS/737 12758 M132/M154/E MS 320W/H75/T15/S/PS/740 57626 M132/M154/E 350 WATT MP 350W/V/UVS/PS/740 22149 M131/O MP350/BU/PS MP350/400/PS/BU-ONLY MPR350/VBU/PA MP 350W/V/EL/UVS/PS/740 44983 M___/O MP 350W/V/ED28/UVS/PS/740 47887 M131/O - MP320/350/PS/BU-ONLY/BT28 MP 350W/C/V/UVS/PS/737 44097 M131/O MP350/C/BU/PS MP350/400/C/PS/BU-ONLY MPR350/C/VBU/PA MP 350W/C/V/UVS/PS/732 27845 M131/O MPR350/C/VBU3K/PA MP 350W/C/V/ED28/UVS/PS/737 55401 M131/O - MP320/350/C/PS/BU-ONLY/BT28 MP 350W/C/V/EL/UVS/PS/737 48952 M___/O MP 350W/BU/ED28/UVS/PS/EM/950 33149 M131/O MP 350W/BU/UVS/PS/EM/950 51628 M131/O CDM350/V/O/PS/4K/ALTO CMH350/V/PA/O MP 350W/C/BU/UVS/PS/EM/950 38197 M131/O CDM350/C/V/O/PS/4K/ALTO CMH350/C/V/PA/O MPSE 350W/BU/UVS/950 62584 M___/O MPSE 350W/C/BU/UVS/950 71035 M___/O MS 350W/V/PS/740 98389 M131/E MS350/BU/PS MVR350/VBU/XHO/PA/E MS 350W/V/ED28/PS/740 52980 M131/E MS 350W/H75/ED28/PS/740 46959 M131/E MS 350W/H75/T15/PS/740 93749 M131/E MS 350W/C/V/PS/737 71329 M131/E MS350/C/BU/PS MVR350/C/VBU/XHO/PA/E MS 350W/C/H75/PS/737 64866 M131/E MS350/HOR/PS 400 WATT MP 400W/V/UVS/PS/740 71642 M135/M155/O MP400/BU/PS MP350/400/PS/BU-ONLY MPR400/VBU/XHO/PA MP 400W/V/EL/UVS/PS/740 56745 M___/O MP 400W/V/ED28/UVS/PS/740 12445 M135/M155/O MP 400W/C/V/UVS/PS/737 45541 M135/M155/O MP400/C/BU/PS MP350/400/C/PS/BU-ONLY MPR400/C/VBU/XHO/PA MP 400W/C/V/ED28/UVS/PS/737 88648 M135/M155/O MP 400W/C/V/EL/UVS/PS/737 78752 M___/O MP 400W/BU/ED28/UVS/PS/EM/950 72315 M155/O CDM400/O/PS/4KED28/ALTO MP 400W/BU/UVS/PS/EM/950 57129 M155/O CMH400/V/PA/O MP 400W/C/BU/UVS/PS/EM/950 89410 M155/O CDM400/C/V/O/PS/4K/ALTO CMH400/C/V/PA/O MPSE 400W/BU/UVS/950 71564 M___/O MPSE 400/C/BU/UVS/950 95103 M___/O MS 400W/V/ED28/PS/740 85260 M135/M155/E MS400/PS/BU-ONLY/BT28 MVR400/VBU/ED28/PA MS 400W/H75/PS/740 58788 M135/M155/E MS400/HOR/PS M400/PS/U MVR400/HOR/PA MS 400W/H75/ED28/PS/740 40124 M135/M155/E M400/PS/U/BT28 MVR400/HOR/ED28/PA MS 400W/V/PS/740 73531 M135/M155/E MS400/BU/PS MS400/PS/BU-ONLY MVR400/VBU/XHO/PA MS 400W/C/V/PS/737 42401 M135/M155/E MS400/C/BU/PS MS400/C/PS/BU-ONLY MVR400/C/VBU/XHO/PA MS 400W/C/V/ED28/PS/737 46416 M135/M155/E MVR400/C/VBU/ED28/PA MS 400W/C/H75/ED28/PS/737 55459 M135/M155/E 450 WATT MP 450W/BU/UVS/PS/740 65072 M144/O MP 450W/C/BU/UVS/PS/737 59216 M144/O MP 450W/BU/EL/UVS/PS/740 30285 M___/O MP 450W/C/BU/EL/UVS/PS/737 24808 M___/O MPSE 450W/BU/UVS/950 95011 M___/O MPSE 450W/C/BU/UVS/950 95012 M___/O MS 450W/V/PS/740 10079 M144/E MS 450W/C/V/PS/737 10138 M144/E 575 WATT MP 575W/BU/BT37/PS/740 60023 M178/O 775 WATT MP 775W/BU/BT37/PS/950 24983 M181/O 875 WATT MP 875W/BU/BT37/PS/740 58953 M166/O MP 875W/C/BU/BT37/PS/737 41686 M166/O MS 875W/BU/BT37/PS/740 22619 M166/E MS 875W/BD/BT37/PS/740 35426 M166/E MS 875W/HOR/BT37/PS/740 33759 M166/E 1000 WATT MS 1000W/BU/BT37/PS/740 71722 M141/E MS1000/BU/BT37/PS M1000/PS/U/BT37 MVR1000/U/BT37/PA MS 1000W/HOR/T25/PS/734 49111 M141/E - 72 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Lamp Cross-Reference TECHNICAL INFORMATION Lamp Description Product ANSI Number Code Philips Osram/ Sylvania GE Lamp Description Product ANSI Number Code Philips Osram/ Sylvania GE Natural White Pulse Start Lamps Probe Start Metal Halide Lamps High CRI - Replacement Lamps for Ceramic Metal Halide 250 WATT MP 250W/BU/UVS/PS/EM/950 19523 M138/M153/O CDM250/V/O/PS/4K ALTO MCP250/PS/BU-ONLY/940 PB CMH250/V/PA/O MPSE 250W/BU/UVS/950 95047 M___/O 320 WATT MP 320W/BU/ED37/UVS/PS/EM/950 98520 M154/O CDM320/O/PS/4K/ALTO MCP320/PS/BU-ONLY/840/BT37 PB CMH320/V/PA/O MP 320W/BU/ED28/UVS/PS/EM/950 98530 M154/O MPSE 320W/BU/ED37/UVS/950 28712 M___/O MPSE 320W/C/BU/ED37/UVS/950 35698 M___/O 350 WATT MP 350W/BU/ED28/UVS/PS/EM/950 33149 M131/O MP 350W/BU/UVS/PS/EM/950 51628 M131/O CDM350/V/O/PS/4K/ALTO CMH350/V/PA/O MP 350W/C/BU/UVS/PS/EM/950 38197 M131/O CDM350/C/V/O/PS/4K/ALTO CMH350/C/V/PA/O MPSE 350W/BU/UVS/950 62584 M___/O MPSE 350W/C/BU/UVS/950 71035 M___/O 400 WATT MP 400W/BU/ED28/UVS/PS/EM/950 72315 M155/O CDM400/O/PS/4KED28/ALTO MP 400W/BU/UVS/PS/EM/950 57129 M155/O CMH400/V/PA/O MP 400W/C/BU/UVS/PS/EM/950 89410 M155/O CDM400/C/V/O/PS/4K/ALTO CMH400/C/V/PA/O MPSE 400W/BU/UVS/950 71564 M___/O MPSE 400/C/BU/UVS/950 95103 M___/O 450 WATT MPSE 450W/BU/UVS/950 95011 M___/O MPSE 450W/C/BU/UVS/950 95012 M___/O 775 WATT MP 775W/BU/BT37/PS/950 24983 M181/O - 175 WATT Probe Start Lamps MPI 175W/BU 32519 M57/O MP175/BU MP175/BU-ONLY MVR175/VBU/O MPI 175W/C/BU 32520 M57/O MP175/C/BU-ONLY MVR175/C/VBU/O MH 175W/U 88791 M57/E MH175/U M175/U MVR175/U MH 175W/U/MED 15556 M57/E MH175/U/M M175/U/MED MVR175/U/MED MH 175W/C/U 96627 M57/E MH175/C/U M175/C/U MVR175/C/U MH 175W/C/U/MED 63187 M57/E MH175/C/U/M M175/C/U/MED MVR175/C/U/MED MS 175W/BU 55087 M57/E MS 175W/BU/MED 70310 M57/E MS 175W/C/BU/3K 20981 M57/E MH175/3K/BU M175/3K/BU-ONLY MS 175W/C/BU/MED/3K 52522 M57/E MH 175W/U/T15 40335 M57/E MS 175W/HOR 57330 M57/E MS175/HOR MVR175/HOR MH 175W/U/5K 79881 M57/E MH 175W/U/T15/10K 70136 M57/E 250 WATT Probe Start Lamps MPI 250W/BU 60722 M58/O MP250/BU MP250/BU-ONLY MPR250/VBU/O MPI 250W/C/BU 60723 M58/O MP250/C/BU-ONLY MPR250/C/VBU/O MH 250W/U 63052 M58/E MH250/U M250/U MVR250/U MH 250W/C/U 61290 M58/E MH250/C/U M250/C/U MVR250/C/U MS 250W/BU 36297 M58/E MS 250W/C/BU/3K 18477 M58/E MH250/3K/BU M250/3K/BU-ONLY MS 250W/HOR 94883 M58/E MS250/HOR MVR250/HOR MH 250W/U/T15 33479 M58/E M250/U/ET18 MS 250W/HOR/T15 88353 M58/E MS 250W/HOR/T15/3K 54843 M58/E MH 250W/U/5K 27252 M58/E MH 250W/U/T15/10K 63897 M58/E 400 WATT Probe Start Lamps MPI 400W/BU 95527 M59/O MP400/BU MP400/BU-ONLY MPR400/VBU/HO/O MPI 400W/C/BU 26091 M59/O MP400/C/BU MP400/C/BU-ONLY MPR400/C/VBU/HO/O MH 400W/U 18520 M59/E MH400/U M400/U MVR400/U MH 400W/U/ED28 57540 M59/E MH400/U/ED28 M400/U/BT28 MVR400/U/ED28 MH 400W/C/U 83545 M59/E MH400/C/U M400/C/U MVR400/C/U MH 400W/C/U/ED28 20753 M59/E M400/C/U/BT28 MVR400/C/U/ED28 MS 400W/BU/ED28 40013 M59/E MS400/BU/ED28 MS400/BU-ONLY/BT-28 MVR400/VBU/ED28/HO MS 400W/HOR 40509 M59/E MS400/HOR MVR400/HOR/MOG MS 400W/HOR/ED28 21929 M59/E MS400/HOR/BT28 MVR400/HOR/BT28 MS 400W/C/HOR 64648 M59/E MS400/C/HOR MVR400/C/HOR/MOG MS 400W/C/HOR/ED28 24573 M59/E MS400/C/HOR/BT28 MH 400W/U/T15 55422 M59/E MS 400W/HOR/T15 55100 M59/E MS 400W/HOR/T15/3K 32225 M59/E MH 400W/U/5K 36813 M59/E MH 400W/U/ED28/10K 27540 M59/E 1000 WATT Probe Start Lamps MH 1000W/U 72051 M47/E MH1000/U M1000/U MVR1000/U MH 1000W/U/BT37 15332 M47/E MH1000/U/BT37 M1000/U/BT37 MVR1000/U/BT37 MH 1000W/C/U 88460 M47/E MH1000/C/U M1000/C/U MVR1000/C/U MS 1000W/BU 89113 M47/E MS1000/BU MS1000/BU-ONLY MVR1000/VBU/HO MS 1000W/BU/BT37 13090 M47/E MS 1000W/BU/T25 78952 M47/E MS 1000W/HOR/BT37/3K 53702 M47/E MH 1000W/U/5K 35914 M47/E MS 1000W/HOR/SPORT 60 47503 M47/E 1500 WATT Probe Start Lamps MH 1500W/HBU 18360 M48/E MH1500/U M1500/BU-HOR MVR1500/HBU MH 1500W/U/XL 12342 M48/E MVR1500/U/SPORTS MS 1500W/HOR/XP/SPORT 60 82070 M48/E 1650 WATT Probe Start Lamps MS 1650W/HOR/XP/SPORT 60 16419 M112/E MVR1650/HOR ® Specialty Lamps Reference Guide Energy Retrofit - Energy Master® Lamps 150 WATT Energy Master Lamps MH 150W/U/EM 44810 M107/E MH150/U/M MH 150W/U/ED28/EM 69559 M107/E M150/SS/U/BT28 MVR150/U/WM MH 150W/C/U/EM 39083 M107/E MH150/C/U/M 360 WATT Energy Master Lamps MPI 360W/BU/EM 38029 M165/O MP360/BU/EW MSP360/SS/BU-ONLY MPR360/VBU/WM/HO/O MPI 360W/C/BU/EM 67293 M165/O MP360/C/BU/EW MSP360/C/SS/BU-ONLY MPR360/C/VBU/WM/HO/O HPS Retrofit Metal Halide - White-Lux® Lamps 250 WATT White-Lux Lamps MPI 250W/BU/LU 24785 S50/O MPI 250W/C/BU/LU 10206 S50/O MVR250/C/VBU/R MH 250W/U/LU 91051 S50/E MVR250/VBU/R 400 WATT White-Lux Lamps MPI 400W/BU/LU 10044 S51/O MH 400W/U/LU/ED28 59441 S51/E MVR400/U/ED28/R MH 400W/U/LU 52134 S51/E MVR400/VBU/R MH 400W/C/U/LU 72190 S51/E MVR400/C/VBU/R 750 WATT White-Lux Lamps MH 750W/U/LU/BT37 33940 S111/E 1000 WATT White-Lux Lamps MS 1000W/V/LU/BT37 35892 S52/E G12 Lamps 70 WATT Pulse Start G12 Lamps HIT 70W/G12/UVS/3K 12108 M85/M98/E HIT 70W/G12/UVS/4K 52983 M85/M98/E 100 WATT Pulse Start G12 Lamps HIT 100W/G12/UVS/4K 89887 M90/E 150 WATT Pulse Start G12 Lamps HIT 150W/G12/UVS/3K 12106 M81/M102/E ARC150/T/U/830/G12 HIT 150W/G12/UVS/4K 25779 M81/M102/E HQI-SE150/NDX ARC150/T/U/840/G12 Double Ended 70 WATT Double Ended MH-DE 70W/UVS/3K 16786 M85/M98/E HQI-DE70/WDX ARC70/TD/UVC/730 MH-DE 70W/UVS/4K 60248 M85/M98/E MHN70/TD/840 HQI-DE70/NDX ARC70/TD/UVC/743 MH-DE 70W/UVS/FS/6K 79470 M85/M98/E 150 WATT Double Ended MH-DE 150W/UVS/3K 11295 M81/M102/E HQI-DE150/WDX ARC150/TD/730/R7S MH-DE 150W/UVS/4K 74756 M81/M102/E HQI-DE150/NDX ARC150/TD/742/R7S MH-DE 150W/UVS/FS/6K 29963 M81/M102/E 250 WATT Double Ended MH-DE 250W/UVS/3K/Fc2 84727 M80/E MH-DE 250W/UVS/4K/Fc2 72748 M80/E MH-DE 250W/UVS/4K/RSC 22468 M80/E 1000 WATT Double Ended MBIL S 1000W 22417 M---/F 1500 WATT Double Ended MBIL S 1500W 22151 M---/F M1500T7/DE SPL1500/H/652 2000 WATT Double Ended MBIL S 2000W 22132 M---/F M2000T8/DE - 73 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Ballast Cross-Reference TECHNICAL INFORMATION Reference Guide Input Voltage 74 Circuit Type HIDirect Catalog # Advanced Catalog # Universal Catalog # Howard Catalog # Input Voltage Circuit Type HIDirect Catalog # Advanced Catalog # Universal Catalog # Howard Catalog # Pulse Start Metal Halide Ballasts Pulse Start Metal Halide Ballasts continued 50 WATT Pulse Start Ballasts ANSI M110 120/208/240/277 HX V90D5731 71A5181 M50MLTLC3M 120/277/347 HX V90J5731 120/277 HX V90H5731 71A5181 M50MLTLC3M 70 WATT Pulse Start Ballasts ANSI M98 120/208/240/277 HX V90D5832 71A5292 M70MLTLC3M 120/208/240/277 HX V90D5833 120/277/347 HX V90J5832 71A52A2 M70TRILC3M 120/277 HX V90H5832 71A5292 M70MLTLC3M 120/277 HX V90H5833 100 WATT Pulse Start Ballasts ANSI M90 120/208/240/277 HX V90D5932 71A5390 M100MLTLC3M 120/277/347 HX V90J5932 71A53A0 M100TRILC3M 120/277 HX V90H5932 71A5390 M100MLTLC3M 277 Reactor V90U5920 71A5337 125 WATT Pulse Start Ballasts ANSI M150 120/208/240/277 CWA V90D8811 120/277/347 CWA V90J8811 120/227 CWA V90H8811 277 Reactor V90U8820 150 WATT Pulse Start Ballasts ANSI M102 120/208/240/277 CWA V90D7110 71A5492 M150MLTLC3M 120/277/347 CWA V90J7110 71A54A3 M150TRILC3M 480/ (120T) CWA V90Y7110T 71A5442-T M15048TLC3M 120/208/240/277 HX V90D7130 71A5492 M150MLTLC3M 120/277/347 HX V90J7130 71A54A2 M150TRILC3M 120/277 HX V90H7130 71A5482 M150MLTLC3M 277 Reactor V90U7120 71A5437 175 WATT Pulse Start Ballasts ANSI M152/M137 120/208/240/277 CWA V90D7210 71A5593 P175MLTAC3M 120/208/240/277 CWA V90D7211 71A5593 P175MLTAC4L 120/277/347 CWA V90J7210 71A55A3 P175TRIAC3M 480/ (120T) CWA V90Y7210T 71A5543-T P17548TAC3M 277 Reactor V90U7221 200 WATT Pulse Start Ballasts ANSI M136 120/208/240/277 CWA V90D7310 71A5692 P200MLTAC3M M0200-71C-611 120/208/240/277 CWA V90D7311 71A5692 120/208/240/277 CWA HX V90D7330 120/277/347 CWA V90J7310 71A56A2 P200TRIAC3M 480/ (120T) CWA V90Y7310T 71A5642-T P20048TAC3M M0200-11C-611 277 Reactor V90U7321 71A5637 P200277RCEM M0200-08C-611 250 WATT Pulse Start Ballasts ANSI M153/M138 120/208/240/277 CWA V90D8410 71A5792 P250MLTAC4M M0250-71C-611 120/208/240/277 CWA V90D8411 71A5792 P250MLTAC4L M0250-71C-611 120/277/347 CWA V90J8410 71A57A2 P250TRIAC4M 480/ (120T) CWA V90Y8410T 71A5742-T P25048TAC4M M0250-11C-611 480/ (120T) CWA V90Y8411T 71A5742-T M0250-11C-611 277 Reactor V90U8421 71A5737 P250277RCEM 320 WATT Pulse Start Ballasts ANSI M154/M132 120/208/240/277 CWA V90D7411 71A5892 P320MLTAC4M M0320-71C-611 120/208/240/277 CWA V90D7412 71A5892 P320MLTAC40 M0320-71C-611 120/208/240/277 CWA V90D7413 71A5892 P320MLTAC40 M0320-71C-611 120/277/347 CWA V90J7411 71A58A2 P320TRIAC4M 480/ (120T) CWA V90Y7411T 71A5842-T P32048TAC4M M0320-11C-611 480/ (120T) CWA V90Y7412T 71A5842-T P32048TAC4L M0320-11C-611 277 Reactor V90U7421 71A5837 P320277RCEM M0320-08C-711 350 WATT Pulse Start Ballasts ANSI M131 120/208/240/277 CWA V90D7512 71A5993 P350MLTAC4M M0350-71C-611 120/208/240/277 CWA V90D7513 71A5993 P350MLTAC4M M0350-71C-611 120/277/347 CWA V90J7512 71A59A3 P350TRIAC3M 480/ (120T) CWA V90Y7512T 71A5943-T P35048TAC4M 277 Reactor V90U7521 71A5937 P350277RECM M0350-08C-711 Note: Venture does not provide any guarantee or warrant on the accuracy of this cross reference guide. User should refer to website, online literature or call sales for their specific requirements. 400 WATT Pulse Start Ballasts ANSI M155/M135 120/208/240/277 CWA V90D7612 71A6092 P400MLTAC4M M0400-71C-611 120/277/347 CWA V90J7612 71A60A2 P400TRIAC4M 480/ (120T) CWA V90Y7612T 71A6042-T P40048TAC4M M0400-11C-611 277 Reactor V90U7621 71A6137 P400277RCEM M0400-08C-711 450 WATT Pulse Start Ballasts ANSI M144 120/208/240/277 CWA V90D8512 71A6393 P450MLTAC4M 120/277/347 CWA V90J8511 71A63A3 P450TRIAC4M 480/ (120T) CWA V90Y8512T 71A6042-T P45048TAC4M 120/208/240/277 HX-HPF V90D8530 277 Reactor V90U8521 71A6337 575 WATT Pulse Start Ballasts ANSI M178 120/208/240/277 HX V90D5530 120/277/347 HX V90J5530 480/ (120T) HX V90Y5530T 277 Reactor V90U5520 750 WATT Pulse Start Ballasts ANSI M149 120/208/240/277 CWA V90D7910 71A64E2 P750MLTAC5M M0750-71C-611 120/277/347 CWA V90J7910 71A64F2 P750TRIAC5M 480/ (120T) CWA V90Y7910T 71A64F2-T P75048TAC5M M0750-11C-611 775 WATT Pulse Start Ballasts ANSI M??? 120/208/240/277 CWA V90D9610 480/ (120T) CWA V90Y9610T 875 WATT Pulse Start Ballasts ANSI M166 120/208/240/277 CWA V90D8611 71A6498 M0875-71C-611 120/208/240/277 CWA V90D8612 71A6498 M0875-71C-611 120/277/347 CWA V90J8611 71A64F8 480/ (120T) CWA V90Y8611T 71A64F8-T M0875-11C-611 480/ (120T) CWA V90Y8612T 71A64F8-T M0875-11C-611 480 Reactor V90Y8620 1000 WATT Pulse Start Ballasts ANSI M141 120/208/240/277 CWA V90D7810 71A6593 P1000MLTAC5M500K M1000-71C-611 120/208/240/277 CWA V90D7811 71A6593 P1000MLTAC5M500K M1000-71C-611 120/277/347 CWA V90J7810 71A65F3 480/ 120T CWA V90Y7810T 71A65F3-T M1000-11C-611 Probe Start Metal Halide Ballasts 175 WATT Probe start Metal Halide BallastsANSI M57/M107 120/208/240/277 CWA V90D6111 71A5570 M175MLTAC3M M0175-71C-212 120/277/347 CWA V90J6111 71A55A0 M175TRIAC3M M0175-59C-212 480/ (120T) CWA V90Y6111T 71A5540-T M17548TAC3N M0175-29C-211 120 CWA V90B6112 71A5500 M17512OAC3M M0175-02C-212 250 WATT (3x4) Probe start Metal Halide Ballasts ANSI M58 120/208/240/277 CWA V90D6211 71A5771 M250MLTAC3M M0250-71C-212 120/277/347 CWA V90J6211 71A57A0 M0250-59C-212 480 CWA V90Y6211 71A5741 M25048TAC3M M0250-11C-212 250 WATT (4x4) Probe Start Metal Halide Ballasts ANSI M58 120/208/240/277 CWA V90D6212 71A550or 71A5790 M250MLTAC4M M0250-71C-211 120/277/347 CWA V90J6212 71A57A0 M250TRIAC4M M0250-59C-211 480/ (120T) CWA V90Y6212T 71A5740 M25048TAC4M M0250-29C-211 or M0250-11C-611 400 WATT Probe Start Metal Halide Ballasts ANSI M59 120/208/240/277 CWA V90D6413 71A6071 M400MLTAC4M M0400-71C-211 120/277/347 CWA V90J6413 71A60A1 M400TRIAC4M M0400-59C-211 480/ (120T) CWA V90Y6413T 71A6041-T M40048TAC4M M0400-29C-211 or M0400-11C-611 1000 WATT Probe Start Metal Halide Ballasts ANSI M47 120/208/240/277 CWA V90D6514 71A6572 M1000MLTAC5M M1000-71C-211 120/277/347 CWA V90J6514 71A65A2 M1000TRIAC5M 480/ (120T) CWA V90Y6514T 71A6542-T M100048TAC5M M1000-11C-212 1500 WATT Probe Start Metal Halide Ballasts ANSI M48 120/208/240/277 CWA V90D6612 71A6772 M1500MLTAC5M M1500-71C-212 480/ (120T) CWA V90Y6612T 71A6742 M150048TAC5M M1500-11C-212 1650 WATT Probe Start Ballasts ANSI M112 120/208/240 CWA V90C6910 71A6890 277/347/480 CWA V90AA6910 71A68F0 - 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Product Descriptions PRODUCT FINDER KEY Lamp Product Codes Ballast Part Number Codes Your lamp has an imprinted code that identifies the important features you need to select a replacement. A complete explanation appears below. The ballast product number gives you complete information about the ballast. An explanation appears below. Lamp Description Example: MP 150W/C/U/ED28/PS/740 Lamp Type: 150 watt Uni-Form® lamp, ANSI Type-O, universal burning, coated Ballast Part Number Example: V90D1434K MP 150W C U ED28 PS 740 Metal halide type Lamp wattage Outer jacket finish Operating position Bulb shape and diameter, if non-standard Pulse start lamp Color temperature family Lamp Description Codes For complete product listings and the most current up-to-date information, visit us on-line at VentureLighting.com 90 D 14 3 4 K Ballast Type Voltage Lamp Type, ANSI Code Circuit Design Version Suffix Ballast Part Number Codes Ballast Type 90 Core and Coil Voltage B 120 C 120/208/240 D 120/208/240/277 E 120/240 H 120/277 J 120/277/347 P 208 U 277 V 347 Y 480 Z 600 AA 277/347/480 AS 347/600 Lamp Type and ANSI Code 10 35W HPS S76 11 50W HPS S68 12 70W HPS S62 13 100W HPS S54 14 150W HPS (55V) S55 16 200W HPS S66 17 250W HPS S50 19 400W HPS S51 23 1000W HPS S52 55 575W PS MH M178 57 50W PS MH M110 58 70W PS MH M98 59 100W PS MH M90 60 150W PS MH (DE) M81 61 175W MH/150W MH M57/M107 62 250W MH M58 63 2X400W MH M59 64 400W MH/360W MH M59/M165 65 1000W MH M47 66 1500W MH M48 67 2000W PS MH (DE) M134 69 1650W MH M112 71 150W PS MH M102 72 175W PS MH M152 73 200W PS MH M136 74 320W PS MH M132/M154 75 350W PS MH M131 76 400W PS MH M155 78 1000W PS MH M141 79 750W PS MH M149 81 70W PS MH (DE) M85 82 100W PS MH (DE) M91 83 250W PS MH (DE) M80 84 250W PS MH M153 85 450W PS MH M144 86 875W PS MH M166 87 300W PS MH M151 88 125W PS MH M150 91 2X1000W MH M47 96 775W PS MH M181 Circuit Type 1 CWA 2 Reactor 3 HX (Lag HPF) 4 HX (Lag NPF) 5 CWI Suffix B with welded bracket C with capacitor K pre-wired with capacitor, ignitor if required, & adapter mounting kit T with 120V tap 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Product Index Position of Operation U Universal operating position BU Lamps designed for base up (±15°) operating position V Lamps designed for a vertical (±15°) operating position H75 Lamps designed for horizontal operation (±75° from horizontal) without the need of a position oriented base socket HBD Lamps designed for horizontal to base down operating position (typically base down ±90°, except 1500W which is base down ±105°) HBU Lamps designed for horizontal to base up operating position (or base up ±90°, except 1500W which is base up ±105°) HOR Horizontal high-performance standard probe start lamps designed for horizontal ±45° operation; uses POM base Bulb Shape, Size and Finish C Lamps with a coated (diffuse) outer jacket MH-DE Double ended lamp ED## Bulb shape and diameter in 1/8 in. (i.e. diameter of ED28 is 3.5 in.) EL A Uni-Form lamp designed for operation on electronic ballasts in dimming applications LU White-Lux® lamp - MH lamp for use with HPS ballast MBIL High wattage, double ended lamp MED Medium base MH Metal halide, typically universal “U”, “HBU” or “HBD” operating positions MP Uni-Form lamps with a protected (shrouded) arc tube designed for open luminaires MPI Lamps with a protected (shrouded) arc tube designed to replace standard (probe start) lamps in open luminaires MPSE Lamps designed for operation on electronic ballast with a protected (shrouded) arc tube MS High output MH lamps for dedicated operating positions PS Pulse start lamp UVS UV Shield® lamps with reduced ultraviolet output Color Temperature and CRI 3K 3000K - 3200K correlated color temperature 4K 3700K - 4000K correlated color temperature 5K 5000K correlated color temperature 6K 6500K correlated color temperature 10K 10,000K correlated color temperature 732 3200K color, 70 CRI lamps 734 3400K color, 68 CRI lamps 737 3700K color, 70 CRI lamps 740 4000K color, 68 CRI lamps 950 Natural White® lamp, 5000K color, high CRI (90+) lamps V Venture Lighting 75 Product Index - Lamps Product Index PRODUCT FINDER KEY Part Product Watts Number Description Catalog Section 35 35 35 35 35 50 50 50 50 50 50 70 70 70 70 70 70 70 70 70 70 70 70 70 70 70 100 100 100 100 100 100 100 100 100 100 100 100 100 125 125 125 125 125 125 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 Retrofit Systems Retrofit Systems Retrofit Systems Retrofit Systems Retrofit Systems Uni-Form® Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Specialty Uni-Form Uni-Form Uni-Form Specialty Uni-Form Uni-Form Uni-Form Specialty Specialty Uni-Form Uni-Form Specialty HPS HPS Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Specialty Uni-Form Uni-Form HPS HPS HPS Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Specialty Specialty Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Specialty Specialty Uni-Form Specialty Specialty Uni-Form Specialty Specialty Uni-Form Uni-Form Uni-Form HPS HPS 60622 60633 60621 60631 60632 10226 10381 13093 30041 32100 52312 12108 12180 14611 16017 16786 22466 40389 45424 52983 60248 67115 78138 79470 84762 51918 11245 11278 15823 22145 27266 67868 79986 89887 96267 96770 25472 69456 69457 13341 25813 35638 43319 61914 76602 11295 12106 13556 21344 22455 22522 22888 25779 29963 32147 39083 44810 58963 69559 74756 80039 94986 99584 64616 28639 VETF-J35W1-MR16SP950-WT VETF-J35W2-MR16SP950-WT MPSE 35W/GX10/MR16/950/SP/WH MPSE 35W/GX10/MR16/950/NFL/WH MPSE 35W/GX10/MR16/950/WFL/WH MP 50W/U/UVS/PS/3K MP 50W/C/U/UVS/PS/3K MH 50W/C/U/PS MP 50W/C/U/UVS/PS MP 50W/U/UVS/PS MH 50W/U/PS HIT 70W/G12/UVS/3K MH 70W/C/U/PS MP 70W/C/U/UVS/PS/3K MH 70W/U/ED28/PS MH-DE 70W/UVS/3K MP 70W/C/U/ED28/UVS/PS/3K MP 70W/U/UVS/PS MP 70W/U/UVS/PS/3K HIT 70W/G12/UVS/4K MH-DE 70W/UVS/4K MP 70W/C/U/UVS/PS MH 70W/U/PS MH-DE 70W/UVS/FS/6K HPS070/U CLEAR LU 70/MED MP 100W/C/U/UVS/PS/3K MP 100W/C/U/UVS/PS MH 100W/C/U/PS MP 100W/C/U/ED28/UVS/PS/3K MH 100W/U/PS MH 100W/U/ED28/PS MH 100W/C/U/ED28/PS HIT 100W/G12/UVS/4K MP 100W/U/UVS/PS MP 100W/U/UVS/PS/3K LU 100 LU 100/MED HPS100/U/MED CLEAR MP 125W/BU/UVS/PS MP 125W/V/ED28/UVS/PS MH 125W/C/HBU/PS MP 125W/C/BU/UVS/PS MH 125W/HBU/ED28/PS MH 125W/HBU/PS MH-DE 150W/UVS/3K HIT 150W/G12/UVS/3K MH 150W/U/ED28/PS/740 MH 150W/C/U/ED28/PS/737 MP 150W/U/UVS/PS/740 MP 150W/U/UVS/PS/732 MP 150W/C/U/UVS/PS/737 HIT 150W/G12/UVS/4K MH-DE 150W/UVS/FS/6K MP 150W/C/U/ED28/UVS/PS/737 MH 150W/C/U/EM MH 150W/U/EM MP 150W/U/ED28/UVS/PS/740 MH 150W/U/ED28/EM MH-DE 150W/UVS/4K MP 150W/C/U/UVS/PS/732 MH 150W/C/U/PS/737 MH 150W/U/PS/740 LU 150/55 HPS150/U/MED CLEAR Page # 44 44 44 44 44 22 22 22 22 22 22 51 23 23 23 51 23 23 23 51 51 23 23 51 59 59 24 24 24 24 24 24 24 51 24 24 59 59 59 25 25 25 25 25 25 51 51 26 26 26 26 26 51 51 26 46 46 26 46 51 26 26 26 59 59 Part Product Watts Number Description Catalog Section 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 290 Probe Start 54 Uni-Form 27 Probe Start 54 Probe Start 54 Probe Start 54 Uni-Form 27 Specialty,Probe Start 50,54 Probe Start 54 Probe Start 54 Probe Start 54 Probe Start 54 Uni-Form 27 Uni-Form 27 Uni-Form 27 Specialty,Probe Start 50,54 Probe Start 54 Probe Start 54 Probe Start 54 Probe Start 54 Uni-Form 28 Uni-Form 28 Uni-Form 28 Uni-Form 28 Uni-Form 28 Uni-Form 28 Uni-Form 28 H75,Uni-Form,Specialty 20,28,50 Specialty 48 Probe Start 54 Natural White® 16 Specialty 51 Specialty 48 Probe Start 54 Specialty,Probe Start 50,54 Probe Start 54 Specialty,Probe Start 50,54 H75,Uni-Form,Specialty 20,29,50 Probe Start 54 Probe Start 54 Probe Start 54 Probe Start 54 Specialty,Probe Start 50,54 Specialty 51 Specialty 51 Specialty,Probe Start 50,54 Specialty 48 Probe Start 54 Natural White 16 Uni-Form 29 Uni-Form 29 Uni-Form 29 H75,Uni-Form 20,29 Uni-Form 29 HPS 59 Natural White 16 15556 16497 20981 32519 32520 34691 40335 52522 55087 57330 63187 68246 68475 69854 70136 70310 79881 88791 96627 22147 44872 57739 59174 60811 60812 70345 70764 10206 18477 19523 22468 24785 27252 33479 36297 54843 57625 60722 60723 61290 63052 63897 72748 84727 88353 91051 94883 95047 32658 49621 64658 81054 81365 35946 95005 MH 175W/U/MED MS 175W/BU/MED/PS/740 MS 175W/C/BU/3K MPI 175W/BU MPI 175W/C/BU MS 175W/C/BU/MED/PS/737 MH 175W/U/T15 MS 175W/C/BU/MED/3K MS 175W/BU MS 175W/HOR MH 175W/C/U/MED MS 175W/C/BU/PS/737 MS 175W/BU/PS/740 MP 175W/BU/UVS/PS/740 MH 175W/U/T15/10K MS 175W/BU/MED MH 175W/U/5K MH 175W/U MH 175W/C/U MP 200W/V/UVS/PS/740 MP 200W/C/V/UVS/PS/732 MS 200W/V/PS/740 MP 200W/C/V/UVS/PS/737 MS 200W/BU/MED/PS/740 MS 200W/C/BU/MED/PS/737 MS 200W/C/V/PS/737 MS 200W/H75/T15/PS/740 MPI 250W/C/BU/LU MS 250W/C/BU/3K MP 250W/BU/UVS/PS/EM/950 MH-DE 250W/UVS/4K/RSC MPI 250W/BU/LU MH 250W/U/5K MH 250W/U/T15 MS 250W/BU MS 250W/HOR/T15/3K MS 250W/H75/T15/PS/740 MPI 250W/BU MP1 250W/C/BU MH 250W/C/U MH 250W/U MH 250W/U/T15/10K MH-DE 250W/UVS/4K/Fc2 MH-DE 250W/UVS/3K/Fc2 MS 250W/HOR/T15 MH 250W/U/LU MS 250W/HOR MPSE 250W/BU/UVS/950 MP 250W/C/BU/UVS/PS/737 MS 250W/V/PS/740 MP 250W/BU/UVS/PS/740 MS 250W/H75/PS/740 MS 250W/C/V/PS/737 LU 250 MPSE 290W/BU/UVS/950 76 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Page # Product Index - Lamps PRODUCT FINDER KEY Part Product Watts Number Description Catalog Section 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 350 360 360 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 Natural White 16 Natural White 16 Uni-Form 30 Uni-Form 30 H75,Uni-Form 20,30 Uni-Form 30 Uni-Form 30 Natural White 16 Uni-Form 30 Uni-Form 30 Natural White 16 H75,Uni-Form 20,30 Uni-Form 30 H75,Uni-Form,Specialty20,30,50 Uni-Form 30 Uni-Form 30 Uni-Form 30 Uni-Form 30 H75,Uni-Form,Specialty 20,30,50 Natural White 16 Uni-Form 32 Uni-Form 32 Natural White 16 Uni-Form 32 Uni-Form 32 H75,Uni-Form 20,32 Uni-Form 32 Uni-Form 32 Natural White 16 Uni-Form 32 Uni-Form 32 Natural White 16 H75,Uni-Form 20,32 Natural White 16 Uni-Form 32 H75,Uni-Form,Specialty 20,32,50 Uni-Form 32 Specialty 46 Specialty 46 Natural White 16 Natural White 16 Natural White 16 Specialty 48 Uni-Form 34 Probe Start 55 Probe Start 55 Probe Start 55 Probe Start 55 Probe Start 55 Probe Start 55 Specialty,Probe Start 50,55 Probe Start 55 Probe Start 55 H75,Uni-Form 20,34 Probe Start 55 Uni-Form 34 Uni-Form 34 Uni-Form 34 98520 98530 10103 10104 12758 21714 25984 28712 32409 32795 35698 47549 52236 57626 59194 66506 67712 77594 79710 38197 22149 27845 33149 44097 44983 46959 47887 48952 51628 52980 55401 62584 64866 71035 71329 93749 98389 38029 67293 57129 72315 89410 10044 12445 18520 20753 21929 24573 26091 27540 32225 36813 40013 40124 40509 42401 45541 46416 MP 320W/BU/ED37/UVS/PS/EM/950 MP 320W/BU/ED28/UVS/PS/EM/950 MP 320W/BU/ED28/UVS/PS/740 MP 320W/C/BU/ED28/UVS/PS/737 MS 320W/C/H75/ED28/PS/737 MP 320W/BU/ED37/UVS/PS/740 MP 320W/V/ED37/EL/UVS/PS/740 MPSE 320W/BU/ED37/UVS/950 MP 320W/C/V/ED37/EL/UVS/PS/737 MP 320W/C/BU/ED37/UVS/PS/737 MPSE 320W/C/BU/ED37/UVS/950 MS 320W/H75/ED28/PS/740 MS 320W/V/ED37/PS/740 MS 320W/H75/T15/S/PS/740 MS 320W/V/ED28/PS/740 MP 320W/C/BU/ED37/UVS/PS/732 MS 320W/C/V/ED37/PS/737 MS 320W/C/V/ED28/PS/737 MS 320W/H75/T15/L/PS/740 MP 350W/C/BU/UVS/PS/EM/950 MP 350W/V/UVS/PS/740 MP 350W/C/V/UVS/PS/732 MP 350W/BU/ED28/UVS/PS/EM/950 MP 350W/C/V/UVS/PS/737 MP 350W/V/EL/UVS/PS/740 MS 350W/H75/ED28/PS/740 MP 350W/V/ED28/UVS/PS/740 MP 350W/C/V/EL/UVS/PS/737 MP 350W/BU/UVS/PS/EM/950 MS 350W/V/ED28/PS/740 MP 350W/C/V/ED28/UVS/PS/737 MPSE 350W/BU/UVS/950 MS 350W/C/H75/PS/737 MPSE 350W/C/BU/UVS/950 MS 350W/C/V/PS/737 MS 350W/H75/T15/PS/740 MS 350W/V/PS/740 MPI 360W/BU/EM MPI 360W/C/BU/EM MP 400W/BU/UVS/PS/EM/950 MP 400W/BU/ED28/UVS/PS/EM/950 MP 400W/C/BU/UVS/PS/EM/950 MPI 400W/BU/LU MP 400W/V/ED28/UVS/PS/740 MH 400W/U MH 400W/C/U/ED28 MS 400W/HOR/ED28 MS 400W/C/HOR/ED28 MPI 400W/C/BU MH 400W/U/ED28/10K MS 400W/HOR/T15/3K MH 400W/U/5K MS 400W/BU/ED28 MS 400W/H75/ED28/PS/740 MS 400W/HOR MS 400W/C/V/PS/737 MP 400W/C/V/UVS/PS/737 MS 400W/C/V/ED28/PS/737 Page # Part Product Watts Number Description Catalog Section Page # 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 450 450 450 450 450 450 450 450 575 750 775 875 875 875 875 875 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1650 2000 Specialty Specialty,Probe Start Specialty,Probe Start H75,Uni-Form Uni-Form Probe Start H75,Uni-Form Specialty Probe Start Natural White Uni-Form Specialty Uni-Form Uni-Form Probe Start Uni-Form Uni-Form Natural White Probe Start HPS Natural White Natural White Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Specialty Natural White Uni-Form Uni-Form Uni-Form Uni-Form Uni-Form Probe Start Probe Start Specialty Probe Start Specialty,Probe Start Uni-Form,Specialty Specialty,Probe Start Uni-Form Probe Start Probe Start Probe Start Probe Start Specialty HPS Specialty,Probe Start Specialty,Probe Start Specialty,Probe Start Specialty Specialty,Probe Start Specialty 48 50,55 50,55 20,34 34 55 20,34 48 55 16 34 48 34 34 55 34 34 16 55 59 16 16 35 35 35 35 35 35 36 48 16 37 37 37 37 37 55 55 48 55 49,55 38,50 49,55 38 55 55 55 55 52 59 49,55 49,55 49,55 52 49,55 52 52134 55100 55422 55459 56745 57540 58788 59441 64648 71564 71642 72190 73531 78752 83545 85260 88648 95103 95527 17934 95011 95012 10079 10138 59216 65072 24908 30285 60023 33940 24983 22619 33759 35426 41686 58953 13090 15332 35892 35914 47503 49111 53702 71722 72051 78952 88460 89113 22417 86346 12342 18360 82070 22151 16419 22132 MH 400W/U/LU MS 400W/HOR/T15 MH 400W/U/T15 MS 400W/C/H75/ED28/PS/737 MP 400W/V/EL/UVS/PS/740 MH 400W/U/ED28 MS 400W/H75/PS/740 MH 400W/U/LU/ED28 MS 400W/C/HOR MPSE 400W/BU/UVS/950 MP 400W/V/UVS/PS/740 MH 400W/C/U/LU MS 400W/V/PS/740 MP 400W/C/V/EL/UVS/PS/737 MH 400W/C/U MS 400W/V/ED28/PS/740 MP 400W/C/V/ED28/UVS/PS/737 MPSE 400W/C/BU/UVS/950 MPI 400W/BU LU 400 MPSE 450W/BU/UVS/950 MPSE 450W/C/BU/UVS/950 MS 450W/V/PS/740 MS 450W/C/V/PS/737 MP 450W/C/BU/UVS/PS/737 MP 450W/BU/UVS/PS/740 MP 450W/C/BU/EL/UVS/PS/737 MP 450W/BU/EL/UVS/PS/740 MP 575W/BU/BT37/PS/740 MH 750W/U/LU/BT37 MP 775W/BU/BT37/PS/950 MS 875W/BU/BT37/PS/740 MS 875W/HOR/BT37/PS/740 MS 875W/BD/BT37/PS/740 MP 875W/C/BU/BT37/PS/737 MP 875W/BU/BT37/PS/740 MS 1000W/BU/BT37 MH 1000W/U/BT37 MS 1000W/V/LU/BT37 MH 1000W/U/5K MS 1000W/HOR/SPORT 60 MS 1000W/HOR/T25/PS/734 MS 1000W/HOR/BT37/3K MS 1000W/BU/BT37/PS/740 MH 1000W/U MS 1000W/BU/T25 MH 1000W/C/U MS 1000W/BU MBIL S 1000W HPS1000/U CLEAR MH 1500W/U/XL MH 1500W/HBU MS 1500W/HOR/XP/SPORT 60 MBIL S 1500W MS 1650W/HOR/XP/SPORT 60 MBIL S 2000W Product Index 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Product Index 77 Product Index - Ballasts Product Index PRODUCT FINDER KEY 78 Part Watts Number Product Description Catalog Page Section # Part Watts Number Product Description Catalog Page Section # 35 35 35 35 50 50 50 50 50 50 50 50 50 70 70 70 70 70 70 70 70 70 70 70 70 100 100 100 100 100 100 100 100 100 100 100 125 125 125 125 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 175 175 175 175 175 175 175 175 175 175 175 175 175 175 175 HPS 120V RCTR HPS 120V RCTR HPS DUAL HX HPS 347V HX HPS 120V RCTR HPS 120V RCTR PS MH QUAD HX HPS DUAL HX HPS DUAL CWI HPS DUAL HX PS MH DUAL HX PS MH TRI HX HPS 347V HX HPS 120V RCTR HPS 120V RCTR HPS QUAD HX PS MH QUAD HX PS MH QUAD HX HPS DUAL CWI HPS DUAL CWI PS MH DUAL HX PS MH DUAL HX HPS TRI HX PS MH TRI HX HPS 600V CWI HPS 120V RCTR HPS 120V RCTR HPS TRI CWI HPS QUAD HX PS MH QUAD HX HPS DUAL CWI PS MH DUAL HX HPS TRI HX PS MH TRI HX PS MH 277V RCTR HPS 600V CWI PS MH QUAD CWA PS MH DUAL CWA PS MH TRI CWA PS MH 277V RCTR HPS 120V RCTR HPS 120V RCTR HPS TRI CWI HPS QUAD HX PS MH QUAD CWA PS MH QUAD HX PS MH DUAL HX HPS TRI HX PS MH TRI CWA PS MH TRI HX PS MH 277V RCTR PS MH 277V RCTR HPS 347V CWI HPS 480V CWI PS MH 480V CWA HPS 600V CWI MH 120V CWA MH QUAD CWA MH QUAD CWA PS MH QUAD CWA PS MH QUAD CWA MH DUAL CWI MH TRI CWA MH TRI CWA PS MH TRI CWA MH 208V CWI PS MH 277V Opti-Wave® MH 480V CWA PS MH 480V CWA PS MH 480V CWA MH 600V CWI HPS HPS HPS HPS HPS HPS Uni-Form® HPS HPS HPS Uni-Form Uni-Form HPS HPS HPS HPS Uni-Form Uni-Form HPS HPS Uni-Form Uni-Form HPS Uni-Form HPS HPS HPS HPS HPS Uni-Form HPS Uni-Form HPS Uni-Form Uni-Form HPS Uni-Form Uni-Form Uni-Form Uni-Form HPS HPS HPS HPS Uni-Form Uni-Form Uni-Form HPS Uni-Form Uni-Form Uni-Form Uni-Form HPS HPS Uni-Form HPS Probe Start Probe Start Probe Start Uni-Form Uni-Form Probe Start Probe Start Probe Start Uni-Form Probe Start Uni-Form Probe Start Uni-Form Uni-Form Probe Start 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 320 350 350 350 350 350 350 350 350 350 350 350 PS MH 277V Opti-Wave Housing PS MH 277V Opti-Wave Housing PS MH QUAD HX Housing PS MH 480V HX Housing PS MH QUAD CWA PS MH QUAD CWA PS MH QUAD CWA PS MH QUAD HX HPS DUAL CWI PS MH TRI CWA PS MH TRI HX PS MH 277V Opti-Wave HPS 347V CWI PS MH 480V CWA PS MH 480V CWA PS MH 480V CWA PS MH 480V HX PS MH 277V Opti-Wave Housing PS MH QUAD CWA Housing HPS DUAL CWI HPS QUAD CWA MH QUAD CWA MH QUAD CWA MH QUAD CWA PS MH QUAD CWA PS MH QUAD CWA HPS DUAL CWI MH DUAL CWI HPS TRI CWA MH TRI CWA MH TRI CWA PS MH TRI CWA MH 208V CWI PS MH 277V Opti-Wave HPS 480V CWA MH 480V CWA MH 480V CWA PS MH 480V CWA PS MH DUAL CWA MH 600V CWI Ventronic 208-277V PS MH 277V Opti-Wave Housing PS MH QUAD HX Housing PS MH QUAD CWA Housing PS MH TRI CWA Housing PS MH 480V CWA Housing PS MH 480V HX Housing PS MH QUAD CWA PS MH QUAD CWA PS MH QUAD CWA PS MH QUAD HX PS MH TRI CWA PS MH TRI HX PS MH 277V Opti-Wave PS MH 480V CWA PS MH 480V CWA PS MH 480V HX Ventronic 208-277V PS MH 277V Opti-Wave Housing PS MH QUAD HX Housing PS MH 480V HX Housing PS MH QUAD CWA PS MH QUAD HX PS MH TRI CWA PS MH TRI HX PS MH 277V Opti-Wave PS MH 480V CWA PS MH 480V HX Systems 43 Systems 43 Systems 43 Systems 43 Uni-Form 28 Uni-Form 28 Uni-Form 28 Uni-Form 28 HPS 61 Uni-Form 28 Uni-Form 28 Uni-Form 28 HPS 61 Uni-Form 28 Uni-Form 28 Uni-Form 28 Uni-Form 28 Systems 43 Systems 43 HPS 61 HPS 61 Probe Start 56 Probe Start 56 Probe Start 56 NW,Uni-Form 17,29 Uni-Form 29 HPS 61 Probe Start 56 HPS 61 Probe Start 56 Probe Start 56 NW,Uni-Form 17,29 Probe Start 56 NW,Uni-Form 17,29 HPS 61 Probe Start 56 Probe Start 56 NW,Uni-Form 17,29 Uni-Form 29 Probe Start 56 NW,Uni-Form,System 17,30,42 Systems 43 Systems 43 Systems 43 Systems 43 Systems 43 Systems 43 NW,Uni-Form 17,31 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form 17,30 NW,Uni-Form,System 17,32,42 Systems 43 Systems 43 Systems 43 NW,Uni-Form 17,32 NW,Uni-Form 17,32 NW,Uni-Form 17,32 NW,Uni-Form 17,32 NW,Uni-Form 17,32 NW,Uni-Form 17,32 NW,Uni-Form 17,32 V90B1020 V90B1020C V90E1030 V90V1030 V90B1120 V90B1120C V90D5731 V90E1131 V90E1151 V90H1132 V90H5731 V90J5731 V90V1131 V90B1222 V90B1222C V90D1233 V90D5832 V90D5833 V90E1250 V90E1252 V90H5832 V90H5833 V90J1232 V90J5832 V90Z1252 V90B1322 V90B1322C V90C1353 V90D1333 V90D5932 V90E1350 V90H5932 V90J1332 V90J5932 V90U5920 V90Z1352 V90D8811 V90H8811 V90J8811 V90U8820 V90B1422 V90B1422C V90C1454 V90D1435 V90D7110 V90D7130 V90H7130 V90J1434 V90J7110 V90J7130 V90U7120 V90U7121 V90V1454T V90Y1454 V90Y7110T V90Z1454T V90B6112 V90D6111 V90D6112 V90D7210 V90D7211 V90E6150 V90J6111 V90J6112 V90J7210 V90P6150T V90U7221 V90Y6111T V90Y7210T V90Y7211T V90Z6150 60 60 60 60 60 60 22 60 60 60 22 22 60 60 60 60 23 23 60 60 23 23 60 23 60 60 60 60 60 24 60 24 60 24 24 60 25 25 25 25 60 60 60 60 26 26 26 60 26 26 26 26 60 60 26 60 56 56 56 27 27 56 56 56 27 56 27 56 27 27 56 OPM-1-200U OPM-2-200U OPM-3-200D(x) OPM-3-200Y V90D7310 V90D7311 V90D7312 V90D7330 V90E1650 V90J7310 V90J7330 V90U7321 V90V1650 V90Y7311T V90Y7312T V90Y7310T V90Y7330T OPM-2-250U OPM-1-250D(x) V90AS1750 V90D1711 V90D6211 V90D6212 V90D6215 V90D8410 V90D8411 V90E1750 V90E6250 V90J1711 V90J6211 V90J6212 V90J8410 V90P6250T V90U8421 V90Y1711T V90Y6211 V90Y6212T V90Y8410T V90Y8411T V90Z6250 OPE320HF OPM-2-320U OPM-3-320D(x) OPM-1-320D(x) OPM-1-320J(x) OPM-1-320Y OPM-3-320Y V90D7411 V90D7412 V90D7413 V90D7430 V90J7411 V90J7430 V90U7421 V90Y7411T V90Y7412T V90Y7430T OPE350HF OPM-2-350U OPM-3-350D(x) OPM-3-350Y V90D7512 V90D7530 V90J7512 V90J7530 V90U7521 V90Y7512T V90Y7530T 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Product Index - Ballasts PRODUCT FINDER KEY Part Watts Number 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 400 430 450 450 450 450 450 450 450 450 450 450 450 575 575 575 575 575 575 575 600 775 775 875 875 875 875 875 875 875 875 875 Product Description OPE400HF Ventronic 208-277V OPHM-2-400U PS MH 277V Opti-Wave Housing OPHM-1-400D(x) PS MH QUAD CWA Housing OPHM-1-400Y PS MH 480V CWA Housing V90AS1950 HPS DUAL CWI V90D1912 HPS QUAD CWA V90D6412 MH QUAD CWA V90D6413 MH QUAD CWA V90D6414 MH QUAD CWA V90D7612 PS MH QUAD CWA V90E1950 HPS DUAL CWI V90E6450 MH DUAL CWI V90J1911 HPS TRI CWA V90J6413 MH TRI CWA V90J7612 PS MH TRI CWA V90P1950T HPS 208V CWI V90P6450T MH 208V CWI V90U7621 PS MH 277V Opti-Wave V90Y1912T HPS 480V CWA V90Y6413T MH 480V CWA V90Y7612T PS MH 480V CWA V90Z6450T MH 600V CWI V90C2050 HPS TRI CWI OPE450HF Ventronic 277V OPHM-2-450U PS MH 277V Opti-Wave Housing OPHM-3-450D(x) PS MH QUAD HX Housing OPHM-3-450Y PS MH 480V HX Housing V90D8512 PS MH QUAD CWA V90D8530 PS MH QUAD HX V90J8511 PS MH TRI CWA V90J8530 PS MH TRI HX V90U8521 PS MH 277V Opti-Wave V90Y8512T PS MH 480V CWA V90Y8530T PS MH 480V HX OPHM-2-575U PS MH 277V Opti-Wave Housing OPHM-3-575D(x) PS MH QUAD HX Housing OPHM-3-575Y PS MH 480V HX Housing V90D5530 PS MH QUAD HX V90J5530 PS MH TRI HX V90U5521 PS MH Opti-Wave V90Y5530T PS MH 480V HX V90D2111 HPS QUAD CWA V90D9610 PS MH QUAD CWA V90Y9610T PS MH CWA OPHM-2-875Y PS MH 480V Opti-Wave Housing OPHM-1-875Y PS MH 480V CWA Housing OPHM-1-875D(x) PS MH QUAD CWA Housing V90D8611 PS MH QUAD CWA V90D8612 PS MH QUAD CWA V90J8611 PS MH TRI CWA V90Y8611T PS MH CWA V90Y8612T PS MH CWA V90Y8620 PS MH 480V Opti-Wave Catalog Page Section # Part Watts Number Product Description Catalog Page Section # NW,Uni-Form,System 17,34,42 Systems 43 Systems 43 Systems 43 HPS 61 HPS 61 Probe Start 57 Probe Start 57 Probe Start 57 Uni-Form 72 HPS 61 Probe Start 57 HPS 61 Probe Start 57 NW,Uni-Form 17,34 HPS 61 Probe Start 57 NW,Uni-Form 17,34 HPS 61 Probe Start 57 NW,Uni-Form 17,34 Probe Start 57 HPS 61 NW,Uni-Form,System 17,35,42 Systems 43 Systems 43 Systems 43 Uni-Form 74 Uni-Form 74 Uni-Form 74 Uni-Form 74 Uni-Form 74 Uni-Form 74 Uni-Form 74 Systems 43 Systems 43 Systems 43 Uni-Form 75 Uni-Form 75 Uni-Form 75 Uni-Form 75 HPS 61 NW,Uni-Form 55 NW,Uni-Form 55 Systems 43 Systems 43 Systems 43 Uni-Form 76 Uni-Form 76 Uni-Form 76 Uni-Form 76 Uni-Form 76 Uni-Form 76 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1650 1650 2000 HPS QUAD CWA HPS QUAD CWA HPS QUAD CWA MH QUAD CWA MH QUAD CWA MH QUAD CWA PS MH QUAD CWA PS MH QUAD CWA HPS DUAL CWI MH DUAL CWI HPS TRI CWA MH TRI CWA PS MH TRI CWA MH 208V CWI HPS 480V CWA MH 480V CWA MH 480V CWA PS MH 480V CWA PS MH CWA HPS 600V CWI MH 600V CWI MH QUAD CWA MH 480V CWA MH TRI CWA MH TRI CWA MH 480V CWA HPS HPS HPS Probe Start Probe Start Probe Start Uni-Form Uni-Form HPS Probe Start HPS Probe Start Uni-Form Probe Start HPS Probe Start Probe Start Uni-Form Uni-Form HPS Probe Start Probe Start Probe Start Probe Start Probe Start Probe Start V90D2310 V90D2311 V90D2315 V90D6514 V90D6516 V90D6517 V90D7810 V90D7811 V90E2353 V90E6550 V90J2310 V90J6514 V90J7810 V90P6550T V90Y2311T V90Y6514T V90Y6517T V90Y7810T V90Y7811T V90Z2353 V90Z6550 V90D6612 V90Y6612T V90AA6910 V90C6910 V90Y6810 61 61 61 57 57 57 77 77 61 57 61 57 77 57 61 57 57 77 77 61 57 57 57 57 57 57 Product Index 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Product Index 79 = Venture’s greener, energy-efficient (88%) ballast: compliant with California Title 20 and federal Energy Independence & Security Act of 2007 Warranty Information ADDITIONAL INFORMATION Limited Warranty on Lamps: For years, most lamp manufacturers have used typical life expectancy as the basis for lamp replacements under warranty. The manufacturer understands the parameters involved in life expectancy and also uses typical life expectancy curves as part of their lamp warranty. The manufacturer is aware of their customers’ needs and offers additional warranty protection. Warranty 1. Upon receipt and/or initial installation by the customer, the manufacturer will replace any lamp determined to be defective in materials, workmanship or proper operating parameters. 2. HIDirect will replace any lamp that fails within one year from the purchase date (based on 5000 hrs/yr operation) when the failure is determined to be lamp related. (Applies to lamps with life ratings of greater than 7500 hours.) 3. During economic life, HIDirect will supply replacement lamps for failed lamps in excess of the failure rate projected by life expectancy curves when the lamps are operated correctly and in accordance with the guidelines outlined in this technical guide. Lamp Performance All performance ratings are based on lamp testing at rated watts, under controlled conditions, using primary AC electrical circuits with the highest quality auxiliary equipment. The performance of any lamp may vary somewhat under typical service conditions. All lamp specifications and ratings are subject to change without notice. Product Index Limited Warranty on Ballasts: Ballast products are warrantied free from manufacturing and workmanship defects for a period of two years from the date of shipment. During this period, HIDirect will, at its option, repair or replace ballast products which prove to be defective or out of specification. This warranty is granted by the manufacturer only to the original purchaser or first end-user of such ballast products. This warranty is conditional upon installation, maintenance and operation in accordance with the manufacturer’s instructions and specifications set forth in the purchase order or contract at the time of order and in accordance with the standards of The National Electric Code (NEC), Underwriters’ Laboratory, Inc. (UL) and the American National Standards Institute (ANSI) and, in Canada, with the standards of the Canadian Standards Association (CSA). Damage by misuse or abnormal conditions of storage, installation, maintenance or operation, including, but not limited to, excessive temperatures or evidence of partial or complete disassembly beyond normal maintenance or expansion procedure void this warranty in its entirety. The conditions of any tests performed concerning any ballast product claimed to be defective in accordance with the terms of this warranty shall be mutually agreed upon in writing between the original purchaser or first end-user and HIDirect and HIDirect may be represented at any such test. No implied statutory warranty of merchantability or fitness for a particular purpose shall apply beyond the afore-mentioned warranty period. This warranty excludes other warranties, expressed or implied and is the exclusive remedy of the claimant. HIDirect shall not be liable for any special, indirect or consequential damages. HIDirect’s liability on any claim of any kind, nature or description arising out of, resulting from or concerning any aspect of this warranty agreement or from the product or services furnished hereunder shall not exceed the price of the specific ballast or ballasts which give rise to the claim. For warranty service or repair, the buyer shall prepay all shipping charges to HIDirect and HIDirect shall pay shipping charges to 80 return the repaired or replaced item to the buyer. However, the buyer shall pay all shipping charges, duties and taxes for products returned to HIDirect from a country other than that of the United States of America. Product replacement/liability limits The foregoing warranty shall be the sole and exclusive remedy of the purchaser and HIDirect’s sole and exclusive remedy to the purchaser. NO WARRANTY OF FITNESS FOR ANY SPECIFIC OR PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. NO OTHER WARRANTY APPLIES. HIDirect will not, under any circumstance, whether as a result of breach of contract, warranty tort or otherwise, be liable for any costs or damages, including lost profits or revenues, incidental, special or consequential damages. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state and province to province. No distributor, salesperson, dealer, retailer or other representative has the authority to change or modify this warranty, either orally or in writing, in any respect. Dimming Policy Warranty policy on the dimming of HIDirect or Venture Lighting metal halide lamps: SCOPE: The manufacturer’s metal halide lamps can only be step or bi-level dimmed by the switched capacitance method on a CWA or CWI ballast. Line voltage and electronic dimming systems are not covered by this policy. Contact HIDirect for further information. WARRANTY POLICY: HIDirect agrees to extend a limited one-year warranty on lamp life to lamps operated on dimmable control gear, provided the following conditions are met: 1) A lamp must never be started by a ballast in the dimmed operating mode. 2) During any lamp start (cold or hot restart), the ballast must meet all of the requirements for starting and sustaining a lamp described in ANSI lamp standard C78.43. 3) The lamp must be allowed to warm up for at least 10 minutes after the lamp has started (20 minutes for lamp wattages greater than 450). Only then can dimming begin. 4) For system design purposes an ANSI reference lamp cannot be dimmed below 50% of the rated lamp wattage at 90% input voltage for CWA or CWI ballasts. 5) Operating position requirements are • Base up ±15°, only, for probe start or pulse start lamps designated as U, BU, HBU • Vertical ±15°, only, for pulse start lamps designated as U, V • Base down ±15°, only, for pulse start lamps designated as BD, HBD • No Horizontal dimming. 6) The ballast input voltage must be kept within the accepted line voltage range for the ballast type (±10% for CWA or CWI ballasts) at all times in dim and full power modes 7) The dimming device should not allow the ballast current crest factor to exceed 1.8. Ballasts/Lamps STANDARD WARRANTY Product Type 50, 70, 100, 125 150, 175, 200, 250 320, 350, 400, 450 575, 775, 875 Magnetic Ballasts Electronic Ballasts “ONE CALL” WARRANTY “One Call” limited warranty program is first in the industry in its comprehensive system coverage. It doubles the warranty period on lamps and ballasts purchased and installed as part of the Uni-Form® pulse start system. Since HIDirect manufactures the lamps and ballasts, customers who purchase a complete system need to make only “one call” to receive full service on any component from HIDirect’s team of technical experts. This means no finger pointing; one source, one call to 1-800-965-2677 for service. Technical assistants will answer all your questions. Warranty Activation/Service Claims – You Must Register To activate the One Call warranty, HIDirect must receive a completed registration form within 30 days after installation of the Uni-Form system. You may complete the registration form included in this catalog or call our toll-free number to have the form sent to you. HIDirect will send an acknowledgment for each registration received. For information, service, technical assistance or replacement claims, call the One Call toll-free number at 1-800-965-2677. If a lamp or ballast in the Uni-Form system fails to operate within the warranty period (based on a maximum 5000hrs./yr operation and normal mortality), HIDirect will provide a free replacement. No reimbursement for labor is made for lamp or ballast replacement. Warranty Terms And Conditions The One Call warranty covers lamps and ballasts purchased and installed together as a Uni-Form system. The installation must be operated under proper environmental conditions and in accordance with current National Electrical Code, Underwriters Laboratory and ANSI specifications. This warranty will be voided if conditions demonstrate abnormal use or stress, such as operating temperatures in excess of maximum rated temperatures, under/over voltage conditions, excessive switching cycles or operating hours or improper lamp or ballast installation. The lamp warranty will be voided if lamps are replaced with any other manufacturer’s lamps. The entire warranty will be voided if ballasts are replaced with any other manufacturer’s ballasts. Product Replacement/liability Limits The foregoing warranty shall be the sole and exclusive remedy of the purchaser and HIDirect’s sole and exclusive remedy to the purchaser. NO WARRANTY OF FITNESS FOR ANY SPECIFIC OR PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. NO OTHER WARRANTY APPLIES. HIDirect will not, under any circumstance, whether as a result of breach of contract or warranty tort, or otherwise, be liable for any costs or damages, including lost profits or revenues, incidental, special or consequential damages. HIDirect reserves the right to examine all failed lamps and ballasts purchased as part of a Uni-Form system. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. No distributor, salesperson, dealer, retailer or other representative has the authority to change or modify this warranty, either orally or in writing, in any respect. This warranty gives you specific legal rights and you may also have other rights which may vary from state to state and province to province. Standard “One Call” Warranty System Period Warranty One Year One Year One Year Two Years One Year Two Years One Year Two Years Two Years Five Years Two Years Three Years 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Warranty Information ADDITIONAL INFORMATION “One Call” System Warranty Registration To receive warranty service, register any installation featuring Uni-Form® pulse start systems. Warranty coverage begins on the date of installation. Call 1-800-965-2677 with any questions. Complete and Return To: HIDirect 10295 Philipp Parkway Sttreetsboro, Ohio 44241 Complete and Fax To: HIDirect 1-800-865-2677 Rep Agency: Contact: Distributor: Contact: Installation Information Today’s Date: Job Name: Location Name: Installation Date: Street Address: City: State/Province: Contact Name: Zip/Postal Code: Phone: Description and Product # (as shown on product packaging) Fixture Type Manufacturer Qty Lamp Product # Lamp Description Ballast Product # Ballast Description (Optional) Restrike Controls Product Number __________________________ Quantity _________________________ Fixture Description and Item#: ______________________________________________________________________________ Note: Must include Uni-Form® pulse start lamps and ballasts purchased together as a system to qualify. Sales order from distributor and invoice from fixture manufacturer, if new fixture is involved, must accompany this form to validate the system warranty. Note: This form must be completed and returned to HIDirect within 30 days of installastion. 81 800-965-2677 Fax 800-865-2677 HIDirect.com E-mail: custserve@hidirect.com Your One-Stop Connection For Replacement and Retrofit Lighting Solutions! Order our most popular products on-line, around the clock! Call 800-965-2677 Fax 800-865-2677 HIDirect.com © 2008 HIDirect HIDirect is a registered trademark of HIDirect. Uni-Form and Venture are registered trademarks of Venture Lighting HID-0220C1-0808