AC/DC Power Supply • Module Type • PFC • 500W Cosel TUNS500F Series TRC ELECTRONICS, INC. Providing exceptional customer service since 1982 AC-DC Power Supplies Power Module type TUNS500F Ordering information TUN 1 2 S 3 500 4 F 5 48 6 -O 1Series name 2Single output 3Output wattage 4Universal Input 5Output voltage 6Optional T : with Mounting hole (f3.4 thru) Y1: Outputvoltage adjustment range ±20% (Only 48V) R1: with Remote ON/OFF R2: with Remote ON/OFF (Low standby power) R *Avoid short circuit between +BC/R and -BC. It may cause the failure of inside components. *Keep TRM open, if output voltage adjustment is not necessary. *If remote sensing is not necessary, connect between +Vout & +S and between -Vout & -S. MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT TUNS500F12 504 12V 42A (Peak 55A) SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT TUNS OUTPUT ACIN 100V ACIN 200V ACIN 100V ACIN 200V ACIN 100V POWER FACTOR (Io=100%) ACIN 200V INRUSH CURRENT LEAKAGE CURRENT[mA] VOLTAGE[V] *3 CURRENT[A] LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +100C*1 RIPPLE[mVp-p] -40 to 0C *1 0 to +100C*1 RIPPLE NOISE[mVp-p] -40 to 0C *1 0 to +65C TEMPERATURE REGULATION[mV] -40 to +100C *2 DRIFT[mV] EFFICIENCY[%] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 *5 OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] REMOTE SENSING REMOTE ON/OFF *5 INPUT-OUTPUT-RC INPUT-FG *5 OUTPUT-RC-FG *5 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD TUNS500F28 504 28V 18A (Peak 24A) TUNS500F48 504 48V 10.5A (Peak 14A) TUNS500F12 TUNS500F28 TUNS500F48 AC85 - 264 1f 6.0typ (Io=100%) 3.0typ (Io=100%) 50/60 (47 - 63) 84typ 87typ 88typ 86typ 90typ 90.5typ 0.96typ 0.93typ Limited by external resistance 0.75max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1) 12 28 48 42 (Peak 55) 18 (Peak 24) 10.5 (Peak 14) 24max 56max 96max 24max 56max 96max 120max 180max 250max 150max 200max 300max 150max 200max 300max 200max 300max 450max 120max 280max 480max 240max 560max 960max 40max 90max 180max Fixed (TRM pin open), adjustable by external resistor or external signal 9.60 - 14.40 22.40 - 33.60 38.40 - 52.80 (-Y1 Option : 38.4 - 57.6) 11.91 - 12.29 27.56 - 28.44 47.24 - 48.76 Works over 101% of peak current and recovers automatically 15.00 - 16.80 35.00 - 39.20 55.20 - 64.80 (-Y1 Option : 60.0 - 67.2) Provided Optional (External power supply is required) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (20±15C) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (20±15C) AC100V 1minute, Cutoff current = 100mA, DC100V 10MW min (20±15C) -40 to +100C (On aluminum base plate), 20 - 95%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000 feet) max -40 to +100C, 20 - 95%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 49.0m/s2 (5G), 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each along X, Y and Z axis UL60950-1, C-UL (CSA60950-1), EN60950-1 Complies with IEC61000-3-2 (Class A) *4 117.3X12.7X61.5mm [4.62X0.5X2.42 inches] (WXHXD) / 190g max Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) Refer to instruction manual for measuring method of electric characteristics. Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output. ( ) means peak current. Avoid operating with peak current continuously. It may cause failure of the components inside the product. There are limitation of available condition of the peak current, such as peak time, duty etc. (Refer to the instruction manual in detail.) Please contact us about another class. ”RC” is applicable when remote control (optional) is added. TUNS-8 TRC ELECTRONICS, INC. 1.888.612.9514 2015/05/19 www.trcelectronics.com/cosel AC/DC Power Supply • Module Type • PFC • 500W Cosel TUNS500F Series TUNS500F TRC ELECTRONICS, INC. Providing exceptional customer service since 1982 External view Recommending size for processing PCB (TOP VIEW) 12.7 ±0.5 Base Plate (Aluminum) [0.5] Lot No. 11- 1.5 15 15 [0.59] [0.59] 44.05 [1.73] 4- 3.5 117.3 max 10.2 10 9 3×4=12 [0.4] [0.39] [0.35] [0.47] 50.8 [2.0] 5.0 [0.2] ±0.5 Case (PBT) [4.62] 106.7 ±0.5 [4.2] [0.47] [0.35] [0.39] [0.4] 3×4=12 9 ±0.5 [2.0] 50.8 [2.42] 10 10.2 [0.39] [0.4] 10 10.2 2- 2 ±0.2 61.5 max (5.3) [0.21] 2- 2.5 106.7 [4.2] 4 [0.16] 15 11- 1 ±0.1 [0.59] 44.05 15 [0.59] [1.73] Control pin for Remote ON/OFF (Option) [0.16] [0.21] 4 Name Plate (5.35) Dimensions in : 4-M3 Mounting Hole AC1 -VOUT AC2 +VOUT -S +S TRM IOG R +BC -BC RC2 (Option) RC1 (Option) Div. : 0.5inch mm [inch] Tolerance : 0.3 [ 0.012] Weight : 190g max Dimensions in mm, [ ]=inches Mounting hole screwing torque : 0.49N m (5.0kgf cm) max 4-FG TUNS 2015/05/19 TRC ELECTRONICS, INC. 1.888.612.9514 www.trcelectronics.com/cosel TUNS-9