PDF processed with CutePDF evaluation edition www.CutePDF.com WFG JOB NO. SHEET NO. − ELECTRICAL ABBREVIATIONS A M A AC AF AFC AFF AFG AHU AIC ALT ARCH AT ATS AUTO AUX AWG AMPERES ALTERNATING CURRENT AMPERE FRAME (BREAKER RATING) ABOVE FINISHED COUNTER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY ALTERNATE ARCHITECT AMPERES TRIP AUTOMATIC TRANSFER SWITCH AUTOMATIC AUXILIARY AMERICAN WIRE GAUGE B BRKR, BKR BLDG MCA MCB MCC MECH MFR MH MIN MISC MLO MOCP MTD MTG MTS MV BREAKER BUILDING C C CB CATV CCTV CONDUIT CIRCUIT BREAKER CABLE TELEVISION CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING COM, COMM COMMUNICATIONS CP CPT CT CU CONTROL PANEL CONTROL POWER TRANSFORMER CURRENT TRANSFORMER COPPER NIC NO NO., NUM, # NTS T NEUTRAL NORMALLY CLOSED OC OCPD OFCI OFOI OH OHE/T D DIRECT CURRENT DISC DISCONNECT DIST DIV DN DP DPDT DPST DISTRIBUTION DIVISION DOWN DISTRIBUTION PANEL DOUBLE POLE DOUBLE THROW DOUBLE POLE SINGLE THROW DWG DRAWING E EG EQUIPMENT GROUND ELEC ELECTRIC, ELECTRICAL EM, EMERG EMERGENCY ELEV ELEVATOR EMT ENCL EQ, EQUIP ELECTRIC METALLIC CONDUIT ENCLOSURE EQUIPMENT EWC EWH E, EX, EXIST ELECTRIC WATER COOLER ELECTRIC WATER HEATER EXISTING P PA PB PDP PE PF PH, PNL PRI PT PVC PWR QTY F FA FAAP FACP FAEP FUSE FIRE ALARM FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM CONTROL PANEL FIRE ALARM EXTENDER PANEL FC FOOT CANDLE FDR FL, FLR FLA FLEX FLUOR FT FEEDER FLOOR FULL LOAD AMPS FLEXIBLE FLUORESCENT FOOT/FEET (') G GROUND GENERATOR GROUND FAULT INTERRUPTER H HORIZONTAL MOUNTING HAND HOLE HAND-OFF-AUTOMATIC HORSEPOWER HIGH PRESSURE SODIUM HOUR HEIGHT HEATER HEATING VENTILATION AND AIR CONDITIONING HERTZ I ISOLATED GROUND INCH/INCHES (") INCANDESCENT J JB, JBOX JUNCTION BOX KEY INTERLOCK 1000 CIRCULAR mils KILOVOLTS (THOUSAND VOLTS) KILOVOLTS-AMPERES (THOUSAND VOLT-AMPS) KILOWATTS (THOUSAND WATTS) KILOWATT-HOURS L LA LAN LC, LCP LP L-L L-N L-G LTG LV HAND-OFF-AUTO SELECTOR SWITCH WITH PILOT LIGHT WYE CONNECTION - SOLID GROUND MANUAL MOTOR STARTER WITH PILOT LIGHT AS INDICATED. M VFD VARIABLE FREQUENCY DRIVE/VARIABLE FREQUENCY MOTOR CONTROLLER C FUSE TB TBB TC TEL,TELE TELECOM TP TV TYP STRESS CONE EMU POLE PUBLIC ADDRESS PULL BOX POWER DISTRIBUTION PANEL PHOTO ELECTRIC POWER FACTOR PHASE PANEL PRIMARY POTENTIAL TRANSFORMER POLYVINYL CHLORIDE POWER ELECTRONIC METERING UNIT LIGHTNING ARRESTOR LOCAL AREA NETWORK LIGHTING CONTROL PANEL LIGHTING PANEL LINE TO LINE LINE TO NEUTRAL LINE TO GROUND LIGHTING LOW VOLTAGE (BELOW 50 VOLTS) LIGHTING CONTROL PANEL, SURFACE MTD. UON. TELECOMMUNICATIONS DATA OUTLET, FLOOR MTD SERVICE FITTING, SURFACE TYPE ("F" DENOTES FLUSH TYPE, "P" DENOTES POKE THRU TYPE) LRP LOW VOLTAGE LIGHTING RELAY PANEL, SURFACE MTD. UON TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, FLOOR MTD SERVICE FITTING, SURFACE TYPE ("F" DENOTES FLUSH TYPE, "P" DENOTES POKE THRU TYPE) MOTOR CONTROL CENTER TELECOMMUNICATIONS VOICE OUTLET, CEILING MTD SERVICE FITTING, SURFACE TYPE ("F" DENOTES FLUSH TYPE) UNINTERRUPTIBLE POWER SUPPLY TELECOMMUNICATIONS DATA OUTLET, CEILING MTD SERVICE FITTING, SURFACE TYPE ("F" DENOTES FLUSH TYPE) UPS TBB TELECOMMUNICATIONS BACKBOARD GAP GENERATOR ANNUNCIATOR (DERANGEMENT) PANEL D D SINGLE RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) LIGHTING FIXTURE - TYPE AS INDICATED (SUBSCRIPT INDICATES SWITCH CONTROL) DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) G GB CT XX WHEN MORE THAN ONE 20A., 1P., 120 VOLT CIRCUIT FEEDS A SURFACE RACEWAY CONNECT RECEPTACLES TO ALTERNATE CIRCUITS AS FOLLOWS - U.O.N. A B C A B C GM DISCLAIMER & TYPICAL NOTES SINGLE POLE SWITCH (SUBSCRIPT INDICATES FIXTURES CONTROLLED) CEILING MOUNTED QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON FACEPLATE. 3 THREE-WAY SWITCH (S3P-THREE-WAY SWITCH WITH PILOT LIGHT) RECEPTACLES MOUNTED ABOVE THE CEILING. 4 FOUR - WAY SWITCH P SINGLE POLE SWITCH WITH PILOT LIGHT K KEY OPERATED SWITCH FLOOR MOUNTED SINGLE RECEPTACLE, 20A, 125V, 2P, 3W. 22733.000 SUPPLIER DRAWN BY REFERENCE SYMBOLS 1 E1-1.0 L D PI PASSIVE INFRARED OCCUPANCY SENSOR (WALL/CEILING) DT ELTD CX PASSIVE INFRARED/ULTRASONIC OCCUPANCY SENSOR (WALL/CEILING) SWITCHED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. PHOTO CELL EMERGENCY DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. EMERGENCY LIGHTING TRANSFER DEVICE FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED) DR DESKTOP RECEPTACLE (DOUG MOCKETT MODEL # PCS36A/EE-90) PSD POWER SUPPLY FOR DOOR(S) WITH ELECTRICAL HARDWARE FEEDER BUSWAY RX REQUEST-FOR-EXIT SENSOR PLUG-IN BUSWAY DGP DATA GATHERING PANEL DO DOOR OPERATING EQUIPMENT ELM ELECTRIC LOCKING/LATCHING AND MONITORING HARDWARE AC ACCESS CONTROL STATION - CARD TYPE K ACCESS CONTROL STATION - KEYPAD TYPE J JUNCTION BOX - CEILING OR WALL MOUNTED - INDICATED IN POWER, LIGHTING & FIRE ALARM SYSTEMS PLANS. SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com MOUNTING HEIGHTS P SR-X WALL SWITCHES 4'-0" AFF RECEPTACLES 1'-6" AFF TELECOMMUNICATIONS OUTLETS 1'-6" AFF TELECOMMUNICATIONS OUTLETS - WALL PHONE 4'-6" AFF CLOCK OUTLETS 7'-6" AFF TV OUTLETS 1'-6" AFF PUSHBUTTONS 4'-0" AFF DISCONNECT SWITCHES 5'-6" AFF MOTOR STARTERS 5'-6" AFF PANELS & CABINETS 6'-0" TO TOP VOLUME CONTROLS 4'-0" AFF DIRECT CONNECTION TO EQUIPMENT NURSE CALL STATIONS 4'-0" AFF POWER SERVICE FITTING (FLOOR/WALL) MOUNTED FOR CONNECTION TO FURNITURE SYSTEM AS SPECIFIED. NURSE CALL DOME LIGHTS 7'-6" AFF SURFACE RACEWAY ("X" DENOTES TYPE AS SPECIFIED) INDIVIDUAL CIRCUIT BREAKERS JUNCTION BOX - FLOOR MOUNTED J P SPECIAL PURPOSE RECEPTACLE. TYPE AS INDICATED ON DRAWINGS. COORDINATE RECEPTACLE TYPE WITH ACTUAL EQUIPMENT PRIOR TO INSTALLATION. FBX J CCTV SURVEILLANCE CAMERA OUTLET - WALL MTD, UON ('CX' DENOTES TYPE AS SPECIFIED) DOOR MONITOR SWITCH AC DEMO KEY NOTE DRAWING NUMBER WHERE DRAWN FLOOR MOUNTED QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON FACEPLATE. ULTRASONIC OCCUPANCY SENSOR (WALL/CEILING) CCTV SURVEILLANCE CAMERA OUTLET - CEILING MTD CCTV 1 DIMMERS 6" ABOVE THE MIRROR INTERCOM 4'-6" AFF FIREMAN'S PHONE 4'-6" AFF 4'-0" AFF GLASS BREAK DETECTOR FIRE ALARM - PULL STATIONS CONDUIT TURNED DOWN CR CARD READER HC DOOR OPERATOR SWITCH FIRE ALARM DEVICES HORN/SPEAKERS/STROBES BETWEEN +80" AND 96"AFF (MOUNTING HEIGHT AT THE BOTTOM OF THE FIRE ALARM DEVICE OR 6" BELOW CEILING WHICH IS LOWER) MD MOTION DETECTOR - CEILING MTD MD MOTION DETECTOR - WALL MTD 1. ALL ELEVATIONS ARE TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED. A INTERCOMMUNICATION SYSTEM ( AI PHONE) 2. REFER TO EQUIPMENT ELEVATION DRAWINGS FOR COORDINATION WITH CASEWORK. ELECTRIC POWER TRANSFER DEVICE 3. MOUNT MANUAL MOTOR STARTER ADJACENT TO OR ON UNIT. 4. REFER TO ARCHITECTURAL A0 SERIES FOR ADDITIONAL MOUNTING HEIGHTS. PTM Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: 4'-0" AFF GB GROUND ROD General Motors Corporation 5'-6" TO TOP ACCESS CONTROL DEVICES VANITY LIGHT IN TOILET Worldwide Facilities Group 4'-0" AFF CONDUIT TURNED UP TELEPHONE MANHOLE FIRM INFO & LOGO 1 E1-1.0 FLOOR MOUNTED QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX RECEPTACLES WITH A COMMON FACEPLATE. SECURITY SYSTEM SYMBOLS CCTV CONSULTANT A/E DRAWING NUMBER WHERE DRAWN FLOOR MOUNTED DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W. PI DT KEY NOTE DIMMER SWITCH OCCUPANCY SENSOR WALL SWITCH U FLOOR MOUNTED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. PROVIDE CORE DRILL PACKAGE TO MAINTAIN FIRE RATING OF FLOOR. EXTEND CONDUIT AND WIRING IN CEILING SPACE OF FLOOR BELOW TO ELECTRICAL CLOSET OR PANELBOARD. LOW VOLTAGE SWITCH OS U PERCENT IMPEDANCE 3 SUPPLIER PE/PM 1 DETAIL NUMBER 3 SUPPLIER CHECKED BY SECTION NUMBER FLOOR MOUNTED SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W. DUAL LEVEL SWITCHING - ONE SWITCH CONTROLS OUTER LAMPS AND ONE SWITCH CONTROLS REMAINING INNER LAMPS. DM ELECTRIC HANDHOLE CERTIFIED BY SUPPLIER PROJECT NO. a DEPT. MGR/SUPR APPROVAL R E V I S I O N S CEILING MOUNTED DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W. CEILING MOUNTED QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX RECEPTACLES WITH A COMMON FACEPLATE. DOOR CONTACT SWITCH EHH PROJECT ARCH/ ENGR APPROVAL DATE CEILING MOUNTED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. SINGLE OR DOUBLE, REMOTE EMERGENCY LIGHTING FIXTURE DC ELECTRIC MANHOLE NOT FOR CON STRU CTIO N NO. LIGHTING FIXTURE TYPE DESIGNATION - "XX" INDICATES SPECIFIC TYPE DEMOLITION WORK EMH TMH N. CEILING MOUNTED SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W. SITE LIGHTING FIXTURE TYPE AS INDICATED RECEIVER/DRIVER UNIT CABLE TRAY MOUNT DEVICES FLUSH WITH CONCEALED CONDUIT, EXCEPT AS NOTED ON THE DRAWINGS AND IN MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS. CEILING MOUNTED SINGLE RECEPTACLE, 20A, 125V, 2P, 3W. EXIT LIGHT - WALL/CEILING MOUNTED - DIRECTIONAL ARROWS AS INDICATED SHADING INDICATES ILLUMINATED FACE R/D GROUND BUS M. LIGHTING TRACK - "X" DENOTES TYPE CONDUIT CAST IN CONCRETE OR BELOW SLAB GROUND CABLE, SIZE AS INDICATED SITE/BUILDING PLAN & NORTH ARROW QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON FACEPLATE. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) HOMERUN TO PANEL WITH CIRCUIT NUMBER(S) AS INDICATED PB FURNITURE LAYOUTS ARE FOR REFERENCE ONLY. COORDINATE THE FINAL LOCATION OF ELECTRICAL DEVICES AND OUTLETS WITH ARCHITECT, OWNER AND FINAL FURNITURE PLANS PRIOR TO INSTALLATION. DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) SHADING INDICATES FIXTURE [CONNECTED TO LIFE SAFETY BRANCH (UNSWITCHED)] [W/FLUORESCENT BATTERY/INVERTER UNIT (UNSWITCHED)] A-1 FB L. SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) SHADING INDICATES FIXTURE [CONNECTED TO CRITICAL BRANCH] [CONNECTED TO GENERATOR CIRCUIT (SWITCHED)] [W/FLUORESCENT BATTERY/INVERTER UNIT (SWITCHED)] ELECTRICAL WIRING SYMBOLS UNDERGROUND CONDUIT/DUCTBANK PROVIDE FEEDERS AND BRANCH CIRCUITS WHICH HAVE AN AMPACITY EQUAL TO OR GREATER THAN THE CIRCUIT OVERCURRENT PROTECTIVE DEVICE RATING, U.O.N. QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX RECEPTACLES WITH A COMMON FACEPLATE. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) 6-30R UG K. GFI, DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) WALLWASH LIGHT FIXTURE, PH CONDUIT RUN CONCEALED IN FINISHED AREAS, EXPOSED IN UNFINISHED AREAS OR BELOW ACCESS FLOORS WHERE EXIT SIGNS ARE INDICATED ABOVE DOOR MOUNT AS FOLLOWS, CENTER THE EXIT SIGN BETWEEN TOP OF DOOR FRAME AND CEILING IF DISTANCE BETWEEN TOP OF DOOR FRAME AND CEILING IS 24 INCHES OR LESS; OTHERWISE MOUNT BOTTOM OF EXIT SIGN 6 INCHES FROM TOP OF DOOR FRAME, MOUNT OTHER WALL MOUNTED EXIT SIGNS IN THE SAME AREA AT THE SAME HEIGHT. COORDINATE WITH ARCHITECTURAL DETAILS. JUNCTION BOX FLOOR OR WALL MOUNTED FOR CONNECTION TO FURNITURE SYSTEM. WALL MOUNTED LIGHTING FIXTURE- TYPE AS INDICATED FLUORESCENT LIGHTING FIXTURE - TYPE AS INDICATED Z %Z J. NOTIFICATION APPLIANCE POWER EXTENDER PANEL ELECTRICAL POWER SYMBOLS a X TRANSFORMER WHERE ELECTRICAL DEVICES WITH DIFFERENT MOUNTING HEIGHTS ARE LOCATED IN THE SAME AREA ALIGN DEVICES VERTICALLY THROUGH THEIR CENTERLINES, UON. NAC TELECOMMUNICATIONS DATA OUTLET ABOVE CEILING ELECTRICAL LIGHTING SYMBOLS WIRE WITH WITHOUT WATT HOUR METER WEATHERPROOF XFMR I. VALVE SUPERVISORY (TAMPER) SWITCH, FOR CONNECTION ONLY GENERATOR G VARIABLE FREQUENCY DRIVE/ VARIABLE FREQUENCY MOTOR CONTROLLER REMOVE DEVICE WHERE DIFFERENT RECESSED ELECTRICAL DEVICES WITH THE SAME MOUNTING HEIGHTS ARE INDICATED SIDE-BY-SIDE, MOUNT THE DEVICES SO THAT THERE IS FOUR INCHES BETWEEN ADJACENT VERTICAL EDGES OF THE FACEPLATES, UON. WATER FLOW SWITCH, FOR CONNECTION ONLY TS DEPT. MGR/SUPR APPROVAL TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, CEILING MTD SERVICE FITTING, SURFACE TYPE ("F" DENOTES FLUSH TYPE) SYMBOL INDICATES TO WHICH PANELBOARD INDICATED CIRCUITS IN THE ROOM ARE TO BE CONNECTED. RP-XXXX VOLTS VOLT-AMPERES X H. WF FIRE ALARM ANNUNCIATOR PANEL (FLUSH/SURFACE) LCP W W W/ W/O WHM WP WHERE MULTIPLE SWITCHES, RECEPTACLES, AND OTHER OUTLETS (EXCEPT WALL PHONES) ARE INDICATED PROVIDE MULTI-GANG BACK BOXES WITH GANG BARRIERS AND A COMMON FACEPLATE. MANUAL FIRE ALARM PULL STATION FAAP TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, WALL MTD. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER) U V VA VFD F FAAP TELECOMMUNICATIONS VOICE OUTLET, FLOOR MTD SERVICE FITTING, SURFACE TYPE ("F" DENOTES FLUSH TYPE, "P" DENOTES POKE THRU TYPE) TERMINAL BLOCK TELEPHONE BACKBOARD TIME CLOCK TELEPHONE TELECOMMUNICATIONS TAMPERPROOF TELEVISION TYPICAL UNDERGROUND PRIMARY UNDERGROUND SECONDARY UNDERGROUND TELEPHONE UNDERWRITER'S LABORATORY UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY G. HEAT DETECTOR CONTACTOR PANELBOARD - (FLUSH/SURFACE) SCHEDULE SECONDARY SQUARE FOOT SPEAKER SPECIFICATION(S) SURGE PROTECTIVE DEVICE SINGLE POLE DOUBLE THROW SINGLE POLE SINGLE THROW STANDARD SWITCH SWITCHBOARD SWITCHGEAR SYMMETRICAL UGP UGS UGT UL UON UPS REFER TO ARCH. REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING MOUNTED DEVICES AND LIGHT FIXTURES, UNLESS OTHERWISE INDICATED. FIRE ALARM REMOTE CONTROL PANEL (FLUSH/SURFACE) TELECOMMUNICATIONS DATA OUTLET, WALL MTD (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER, "W" INDICATES WALL PHONE HEIGHT) DISTRIBUTION PANELBOARD RELOCATE AS SHOWN REMOTE CONTROL LIGHTING PANEL RECEPTACLE REFRIGERATOR RADIO FREQUENCY RIGID STEEL CONDUIT RATED (RUNNING) LOAD AMPS ROOM RECEPTACLE PANELBOARD UNDERGROUND F. FACP TELECOMMUNICATIONS VOICE OUTLET, WALL MTD (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER, "W" INDICATES WALL PHONE HEIGHT, "PY" INDICATES PAY PHONE) GROUND OPPOSITE UG SMOKE DETECTOR - HVAC DUCT TYPE LIGHTNING ARRESTOR S SCH, SCHED SEC SF SPKR SPEC(S) SPD SPDT SPST STD SW SWBD SWGR SYM LIMIT VOLTAGE DROP TO 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. INCLUDE DERATING FACTOR FOR ROOF-MOUNTED CONDUITS. FACP TELECOMMUNICATION SYMBOLS R R, RE RCLP RCPT REF RF RSC RLA RM RP E. FA SPEAKER W/STROBE - CEILING MOUNTED EMERGENCY POWER OFF AUTOMATIC TRANSFER SWITCH BUS DUCT PLUG-IN UNIT OVERHEAD OVERHEAD ELECTRIC/TELEPHONE QUANTITY SMOKE DETECTOR - CEILING OR SURFACE MOUNTED FA SPEAKER W/STROBE - WALL MOUNTED PUSHBUTTON STATION STATIONARY CIRCUIT BREAKER V K K Kcmil KV KVA KW KWH DELTA CONNECTION KEY INTERLOCKING SYSTEM T IG IN INCAND COMBINATION MOTOR STARTER WITH DISCONNECT SWITCH. PROVIDE SWITCH AND FUSE AMACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY, UON K Q F H HH HOA HP HPS HR HT HTR HVAC HZ CURRENT TRANSFORMER DRAWOUT TYPE, CIRCUIT BREAKER P DC INSTALL ELECTRICAL WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL BUILDING AND FIRE CODES, IN A NEAT AND WORKMANLIKE MANNER. FA SPEAKER - CEILING MOUNTED CONTROL POWER TRANSFORMER PACKAGE CONTROL UNIT (PROVIDED BY EQUIPMENT SUPPLIER) ON CENTER OVERCURRENT PROTECTION DEVICE OWNER FURNISHED, CONTRACTOR INSTALLED OWNER FURNISHED, OWNER INSTALLED D. FA SPEAKER - WALL MOUNTED CIRCUIT BREAKER IN NEMA 1 ENCLOSURE (FLUSH/SURFACE) PC ATS PROVIDE FIRE STOPPING FOR CONDUITS AND ELECTRICAL EQUIPMENT FOR FLOOR SLABS, WALLS AND CEILINGS TO MAINTAIN FIRE RATING. DISCONNECT SWITCH, FUSED. PROVIDE SWITCH AND FUSE AMACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY, UON ELECTRIC INTERLOCK SYSTEM NOT IN CONTRACT NORMALLY OPEN NUMBER NOT TO SCALE C. TRANSFORMER - TYPE AND RATING AS INDICATED E NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION PROVIDE A DEDICATED NEUTRAL WIRE FOR EACH BRANCH CIRCUIT. COORDINATE DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. STROBE - CEILING MOUNTED POTENTIAL TRANSFORMER CPT B. DISCONNECT SWITCH, NON-FUSED PROVIDE SWITCH AMPACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY, UON PROJECT ARCH/ ENGR APPROVAL ISSUED FOR 22MAY13 BIDS PROVIDE 1#12 + 1#12N + 1#12G FOR 20A BRANCH CIRCUITING, UON; MAXIMUM OF THREE CIRCUITS PER CONDUIT UON; MINIMUM CONDUIT SIZE OF 3/4" C, UON. FUSED SWITCH CB GENERAL NOTES A. STROBE - WALL MOUNTED O OPP G, GND, GRD GEN GFI MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MECHANICAL MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MAXIMUM OVERCURRENT PROTECTION MOUNTED MOUNTING MANUAL TRANSFER SWITCH MEDIUM VOLTAGE (OVER 600V LESS THAN 35KV) FIRE ALARM SYMBOLS MOTOR AND CONNECTION SWITCH - SINGLE THROW N N NC NEC NEMA ELECTRICAL EQUIPMENT SYMBOLS DISTRIBUTION AND DIAGRAM SYMBOLS DATE MOUNTING HEIGHT NOTES: ELECTRICAL LEGENDS, ABBREVIATIONS AND GENERAL NOTES WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE DATE 22MAY13 FILE PLOT DATE STAMP E0−001 5/21/2013 12:15:42 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS DRAWING NOTES FEEDER & BRANCH CIRCUIT SIZING SCHEDULE GENERAL PURPOSE CIRCUIT SIZING SCHEDULES NOTES: (NOTES 1 & 2) OVERCURRENT DEVICE RATING (AMPERES) MAX. CIRCUIT LOAD (AMPS) CONDUIT SIZE 1. 3 WIRE 4 WIRE (3PH & 1N) 3/4" 3/4" 3/4" 10 3/4" 3/4" 3/4" 8 10 3/4" 3/4" 3/4" 45-50 8(6) 10 3/4" 3/4" 3/4"(1") 60 6(4) 10 3/4"(1") 3/4"(1") 1"(1 1/4") 70 6(4) 8 3/4"(1") 3/4"(1") 1"(1 1/4") 80-90 4(2) 8 1" 1"(1 1/4") 1 1/4" 100 3(2) 8 1"(1 1/4") 1 1/4" 1 1/4" 110 2(1) 6 1 1/4" 125 1(1/0) 6 1 1/4" 1 1/2" 1 1/2"(2") 150 1/0 6 1 1/4" 1 1/2" 2" 175 2/0 6 1 1/2" 2" 2" 200 3/0 6 1 1/2" 2" 2" 225 4/0 4 2" 2" 2 1/2" 250 250 4 2" 2 1/2" 2 1/2" 300 350 4 2 1/2" 3" 3" 350 500 3 3" 3" 3 1/2" 400 600 3 3" 4" 4" 450 2-4/0 2-2 2-2" 2-2" 2-2 1/2" 500 2-250 2-2 2-2" 2-2 1/2" 2-2 1/2" 600 2-350 2-1 2-2 1/2" 2-3" 2-3" 700 2-500 2-1/0 2-3" 2-3" 2-3 1/2" 800 2-600 2-1/0 2-3" 2-3" 2-4" 1000 3-400 3-2/0 3-2 1/2" 3-3" 3-3" 1200 4-350 4-3/0 4-2 1/2" 4-3" 4-3" 1600 5-400 5-4/0 5-2 1/2" 5-3" 5-3" 2000 6-400 6-250 6-2 1/2" 6-3" 6-3" PHASE & NEUTRAL E.G. 15-20 12 12 25-30 10 35-40 2 WIRE 1 1/4"(1 1/2") NOTE 2. 3. 4. 5. 6. BASED ON THHN/THWN, 90°., 600V., INSULATED, COPPER WIRE APPLIED AT 75°FOR TERMINATIONS RATED AT 60°C/75°C AND 75°C. FOR TERMINATIONS RATED AT 60°C PROVIDE WIRE AND CONDUIT SIZES INDICATED IN PARENTHESIS. BASED ON WIRE OUTSIDE DIAMETERS AND RIGID METALLIC CONDUIT INSIDE DIAMETERS AS PROVIDED IN THE NEC. DO NOT REDUCE CONDUIT SIZE FOR NON-RIGID METALLIC APPLICATION. REFER TO NEC FOR CONDUIT TYPES MORE RESTRICTIVE THAN RIGID METALLIC. BASED ON MOTOR FULL LOAD AMPERES AS PROVIDED BY THE NEC. BASED ON MOTOR RUNNING OVERLOAD PROTECTION PROVIDED BY THERMAL OVERLOAD RELAYS. MOTOR STARTING TYPE BASED ON 460V., 3 PHASE, FULL VOLTAGE NONREVERSING EXCEPT FOR MOTORS SIZED 75HP OR GREATER WHICH ARE BASED ON 460V., 3 PHASE, PART WINDING REDUCED VOLTAGE STARTING. TRANSFORMER CIRCUITS BASED ON 480V TO 208/120V., 3 PHASE, 4 WIRE,DRY TYPE. 1 1/4"(1 1/2") SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES MOTOR CIRCUIT SIZING SCHEDULE 480V., THREE PHASE CIRCUIT LENGTH TABLE BREAKER AMPACITY (AMPS) WIRE SIZE - AWG OR KCMIL (FOR 460V., 3 PHASE MOTORS) (NOTES 3,4,5) MAXIMUM LENGTH IN FEET STARTER CONDUIT & WIRE MOTOR HP SWITCH/FUSE CIRCUIT BREAKER SIZE/TYPE PHASE E.G. CONDUIT NO.12 NO.10 NO.8 NO.6 NO.4 NO.2 NO.1 1/0 2/0 3/0 4/0 250 350 500 2-3/0 2-4/0 2-250 2-350 2-500 3-300 3-400 4-350 5-400 6-400 6-500 1/2 30/3A. 15A 1 12 12 3/4" 20 16 253 403 642 1019 - - - - - - - - - - - - - - - - - - - - - 3/4 30/3A. 15A 1 12 12 3/4" 30 24 - 269 428 679 1079 - - - - - - - - - - - - - - - - - - - - 1 30/6A. 15A 1 12 12 3/4" 40 32 - - 321 509 809 1293 - - - - - - - - - - - - - - - - - - - 1 1/2 30/6A. 15A 1 12 12 3/4" 50 40 - - - 408 648 1034 - - - - - - - - - - - - - - - - - - - 2 30/6A. 15A 1 12 12 3/4" 60 48 - - - - 540 862 1083 - - - - - - - - - - - - - - - - - - 3 30/10A. 15A 1 12 12 3/4" 70 56 - - - - - 739 928 1169 - - - - - - - - - - - - - - - - - 5 30/15A. 20A 1 12 12 3/4" 80 64 - - - - - 646 812 1023 1286 - - - - - - - - - - - - - - - - 7 1/2 30/20A. 30A 1 12 10 3/4" 90 72 - - - - - 574 722 909 1143 - - - - - - - - - - - - - - - - 10 30/25A. 35A 1 12 10 3/4" 15 30/30A. 50A 2 10 10 3/4" 100 80 - - - - - - 650 818 1029 - - - - - - - - - - - - - - - - 20 60/40A. 60A 2 8 10 3/4" 125 100 - - - - - - - 655 823 1043 - - - - - - - - - - - - - - - 25 60/50A. 75A 2 6 10 1" 150 120 - - - - - - - 546 689 869 1107 - - - - - - - - - - - - - - 30 60/60A. 100A 3 6 10 1" 175 140 - - - - - - - - 588 745 949 1110 - - - - - - - - - - - - - 40 100/80A. 125A 3 4 8 1 1/2" 200 160 - - - - - - - - - 652 830 971 1360 - - - - - - - - - - - - 50 100/100A. 150A 3 3 8 1 1/2" 225 180 - - - - - - - - - - 738 863 1209 1743 - - - - - - - - - - - 60 200/125A. 175A 4 1 6 1 1/2" 250 200 - - - - - - - - - - - 777 1088 1569 1043 - - - - - - - - - - 75 200/150A. 200A 4 1/0 6 1 1/2" 300 240 - - - - - - - - - - - - 907 1307 869 1107 - - - - - - - - - 100 200/200A. 225A 4 2/0 6 2" 350 280 - - - - - - - - - - - - - 1120 745 949 1110 - - - - - - - - 125 200/200A. 225A 5 3/0 6 2" 400 320 - - - - - - - - - - - - - 980 652 830 971 1360 - - - - - - - 150 400/250A. 300A 5 4/0 4 2 1/2" 450 360 - - - - - - - - - - - - - - - 738 863 1209 - - - - - - - 200 400/350A. 400A 5 350 4 3" 500 400 - - - - - - - - - - - - - - - - 777 1088 1569 - - - - - - 600 480 - - - - - - - - - - - - - - - - - 907 1307 1165 - - - - - 700 560 - - - - - - - - - - - - - - - - - - 1120 999 1346 - - - - 800 640 - - - - - - - - - - - - - - - - - - - 874 1177 1360 - - - 1000 800 - - - - - - - - - - - - - - - - - - - - 942 1088 1569 - - 1200 960 - - - - - - - - - - - - - - - - - - - - - 907 1307 - - 1600 1200 - - - - - - - - - - - - - - - - - - - - - - 980 1226 1307 1800 1440 - - - - - - - - - - - - - - - - - - - - - - - 1089 1177 2000 1600 - - - - - - - - - - - - - - - - - - - - - - - 980 1137 NO. BREAKER AMPACITY (AMPS) 20 30 MAX. MAX. CIRCUIT CIRCUIT CURRENT LOAD (AMPS) (VOLT-AMPS) MAXIMUM LENGTH IN FEET NO.12 NO.10 NO.8 NO.6 NO.4 4 480 220 349 556 882 - 8 960 110 174 278 441 12 1440 73 116 185 16 1920 55 87 139 24 2880 - 58 93 BREAKER AMPACITY (AMPS) MAX. MAX. CIRCUIT CIRCUIT LOAD LOAD (VOLT-AMPS) (VOLT-AMPS) 22733.000 SUPPLIER DRAWN BY SUPPLIER PE/PM CONSULTANT A/E NO.12 NO.10 NO.8 NO.6 NO.4 BREAKER AMPACITY (AMPS) 20 MAX. CIRCUIT LOAD (AMPS) MAX. CIRCUIT LOAD (VOLT-AMPS) 4 (NOTE 6) 277V. SINGLE PHASE CIRCUIT LENGTH TABLE BREAKER AMPACITY (AMPS) MAXIMUM LENGTH IN FEET NO.12 NO.10 NO.8 NO.6 NO.4 1440 439 698 1113 - - 20 MAXIMUM LENGTH IN FEET NO.12 NO.10 200 300 PRIMARY CIRCUIT (480V.) SWITCH/FUSE OR CIRCUIT BREAKER PRIMARY FEEDER SWITCH/FUSE OR CIRCUIT BREAKER SYSTEM/EQUIPMENT BONDING JUMPER (GROUND WIRE) SECONDARY FEEDER 9 30/20A. 20A., 3W. 30/30A. #8 30A., 4W. 15 30/25A. 25A., 3W. 60/60A. #8 60A., 4W. 30 60/45A. 45A., 3W. 100/100A. #8 100A., 4W. 45 100/70A. 70A., 3W. 200/175A. #4 175A., 4W. 75 200/125A. 125A., 3W. 400/300A. #2 300A., 4W. 200/175A. 175A., 3W. 400/400A. #1/0 400A., 4W. 380 605 964 - - 701 8 1664 190 302 482 765 - 8 2880 220 349 557 883 - 294 467 12 2496 127 202 321 510 810 12 4320 127 233 371 589 935 150 400/225A. 225A., 3W. 600/600A. #2/0 600A., 4W. 221 350 16 3328 95 151 241 382 607 16 5760 95 175 278 442 701 225 400/350A. 350A., 3W. 800/800A. #3/0 800A., 4W. 300 600/500A. 500A., 3W. 1200/1000A. #3/0 1000A., 4W. 30 24 4992 - 101 161 255 405 30 24 8640 - 116 186 294 112 1/2 SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com SECONDARY CIRCUIT (208/120V.) 832 234 FIRM INFO & LOGO TRANSFORMER CIRCUIT SIZING SCHEDULE - GENERAL PURPOSE TYPE 4 147 20 MAXIMUM LENGTH IN FEET CERTIFIED BY SUPPLIER PROJECT NO. SUPPLIER CHECKED BY 208V. THREE PHASE CIRCUIT LENGTH TABLE 208V. SINGLE PHASE CIRCUIT LENGTH TABLE DEPT. MGR/SUPR APPROVAL R E V I S I O N S TRANSF. KVA 120V. SINGLE PHASE CIRCUIT LENGTH TABLE PROJECT ARCH/ ENGR APPROVAL DATE Worldwide Facilities Group General Motors Corporation 468 Warren Technical Center Campus 40 32 3840 - - 70 110 175 40 32 6656 - - 121 191 304 40 32 11520 - - 139 221 351 50 40 4800 - - - 88 140 50 40 8320 - - - 153 243 50 40 14400 - - - 177 281 60 48 5760 - - - - 117 60 48 9984 - - - - 202 60 48 17280 - - - - 234 Site ID: 1563 Structure ID: 4235 Level: CIRCUIT MAXIMUM DISTANCE TABLES NOTES: 1. 2. CIRCUIT MAXIMUM DISTANCE IS BASED ON NEC CHAPTER 9, TABLE 8 CONDUCTOR PROPERTIES FOR COATED COPPER CONDUCTORS AT 75 DEGREES CELSIUS. MAXIMUM CIRCUIT LOAD FOR DISTANCE IS BASED ON NEC 220-10(b) ELECTRICAL SCHEDULES, TABLES AND DRAWING NOTES WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 1 : 1 DATE 22MAY13 FILE PLOT DATE STAMP E0−002 5/21/2013 12:15:45 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS TYPE DESCRIPTION F2 2'X4' PRISMATIC TROFFER F3 1' X 12' RECESSED LINEAR FLUORESCENT WITH UNIFORM DIFFUSE FLEXIBLE TRNASLUCENT WHITE PVC MEMBRANE LENS, 10" DEPTH, FLANGED DOOR FOR DRYWALL APPLICATION, WHITE FRAME AND INTEGRAL 1% DIMMING BALLAST. COMBINE THREE 4' FIXTURE MODULES END-TO-END TO CREATE SINGLE 12' FIXTURE. PROVIDE CUSTOM LENS FRAME TO ALLOW MULTIPLE FIXTURE MODULES TO BUTT END-TO-END WITHOUT LIGHT LEAKS. 1'X4' CHAIN HUNG INDUSTRIAL F4 F5 48" LENGTH RECESSED LINEAR FLUORESCENT WITH 2.5" APERTURE, MICROPRISMATIC LENS, TRIMLESS FLANGE, INTERNAL REFLECTOR, WHITE FINISH AND INTEGRAL ELECTRONIC BALLAST. F6 1' X 4' RECESSED LINEAR FLUORESCENT WITH UNIFORM DIFFUSE FLEXIBLE TRNASLUCENT WHITE PVC MEMBRANE LENS, 10" DEPTH, FLANGED DOOR FOR DRYWALL APPLICATION, WHITE FRAME AND INTEGRAL DIMMING BALLAST. SAME AS TYPE F6 BUT WITH STANDARD BALLAST F6A L1 L2 L3 L5 RGBW MULTI-CHIP LED MOTORIZED WASH WITH 23° - 58° ZOOM, 540° PAN, 270° TILT, 16 BIT RGBW COLOR MIXING, VARIABLE FAN COOLING, COMPATIBLE WITH DMX512 CONSOLES, 5 PIN DMX IN AND THRU CONNECTIONS, WHITE POWER CORD AND WHITE HOUSING FINISH. 400W ARC MOTORIZED SPOT WITH 15° - 36° ZOOM, 540° PAN, 260° TILT, 16 BIT CMY COLOR MIXING, VARIABLE FAN COOLING, ROTATING GOBO WHEEL, MECHANICAL IRIS, VARIABLE BEAM FOCUS, COMPATIBLE WITH DMX512 CONSOLES, 5 PIN DMX IN AND THRU CONNECTIONS WHITE POWER CORD AND WHITE HOUSING FINISH. RGBW MULTI-CHIP LED MOTORIZED WASH WITH 37 X 10W RGBW MULTICHIPS, 8° - 63° 1/2 PEAK BEAM OPTICAL ZOOM, 450° PAN, 300° TILT, 16 BIT RGBW COLOR MIXING, VARIABLE FAN COOLING, COMPATIBLE WITH DMX512 CONSOLES, 5 PIN DMX IN AND THRU CONNECTIONS, WHITE POWER CORD AND WHITE HOUSING FINISH. LINEAR WHITE LED WITH WIDE 110°X110° OPTICS, WHITE FINISH, LOCKABLE ROTATABLE SURFACE MOUNT, MOUNTING TRACK, 16 BIT DMX DIMMABLE TO 1%, DMX ADRESSIBLE BY FIXTURE LENGTH, INTEGRAL DRIVER AND END TO END CONNECTORS. MANUFACTURER MODEL MANUFACTURER (OPTION 1) LITHONIA SP8 COOPER (METALUX) MARK ARCHITECTURAL LIGHTING VEIL LITHONIA DIM XAL EE - LIGHTING FIXTURE SCHEDULE1 MODEL MANUFACTURER MODEL (OPTION 1) (OPTION 2) (OPTION 2) GR8 LIGHTOLIER XP LOAD LAMP 64 VA (2) 32W T8 105 VA COOPER (METALUX) PROGRAMMED RAPID START (1) 32W T8 4100K NEMA PREMIUM CCT IN CROSS PROGRAMMED SECTION START MOUNTING 120 V RECESSED 120 V RECESSED PROVIDE INTEGRAL 1% DIMMING BALLAST. PROVIDE SHOP DRAWINGS SHOWING ALL FIXTURE MODULES AND SECTIONS OF CUSTOM LENS FRAME PRIOR TO FINAL APPROVAL. 120 V CHAIN HUNG PROVIDE WIRE GUARD AND CHAIN HANGING KIT, SURFACE MOUNT IN AREAS WHERE A DROP CEILING IS PROVIDED. PROVIDE SPECIALFX LIGHTING FADE-NOT POLYSLEEVE NEUTRAL DENSITY FILTER FOR EACH LAMP. PROVIDE SAMPLES OF 2' T5 FADE-NOT POLY SLEEVES IN COLOR OPTIONS ROSCO N.15 #3415, ROSCO N.3 #3402, ROSCO N.6 #3403 AND ROSCOSUN N.9 #3404 FOR ON-SITE MOCKUP. FINAL FADE-NOT POLY SLEEVE COLOR SPECIFICATION TO BE DETERMINED AFTER ON-SITE MOCKUP. COORDINATE MOCKUP WITH LIGHTING DESIGNER. PROVIDE INTEGRAL DIMMING BALLAST (2) 32W T8 MINIMAL 60 33 VA (1) 28W T5; 3000K CCT; 80+ CRI IN CROSS SECTION 120 V RECESSED MARK ARCHITECTURAL LIGHTING VEIL 66 VA 120 V RECESSED MARK ARCHITECTURAL VEIL 66 VA 120 V RECESSED PHILIPS VARI-LITE VLX WASH 820 VA (2) 32W T8 4100K CCT; 80+ CRI IN CROSS SECTION (2) 32W T8 4100K CCT; 80+ CRI IN CROSS SECTION 7 X 120W RGBW MULTICHIP LED 120 V C-CLAMP PHILIPS VARI-LITE VL440 SPOT 792 VA 400W ARC 120 V ROBE ROBIN 1200 LEDWASH 680 VA 37 X 10W RGBW MULTICHIP LED 120 V COLOR KINETICS eW COVE MX PRECISION DIM 50 VA WHITE LED; MIN 700 LUMEN; 4000K CCT; 80+ CRI; 4 SCDM MAX WHITE LED; 20W; 4000K CCT; 80+ CRI; 4 SCDM MAX 120 V LUMENCOVE HO PROGRAMMED RAPID START VOLTAGE 64 VA LUMENPULSE LIGHTOLIER BALLAST L6 MOTORIZED LED TRACK HEAD WITH 11° OPTICS, 4000K WHITE LED MODULE, WHITE FINISH, DMX DRIVER AND HOOK CLAMP FOR MOUNTING TO THEATRICAL TRUSS. REMOTE CONTROLLED LIGHTING LTD DR8 27 VA L6A SAME AS L6 BUT WITH TRACK MOUNT ADAPTER FOR MOUNTING TO FACTORY-CURVED REMOTE CONTROLLED LIGHTING LTD 2 CIRCUIT DMX DATA ENABLED TRACK. ENTIRE TRACK ASSEMBELY TO HAVE WHITE FINISH. DR8 27 VA WHITE LED; 20W; 4000K CCT; 80+ CRI; 4 SCDM MAX 120 V L6B SAME AS L6 BUT WITH 24° BEAM OPTICS AND TRACK MOUNT ADAPTER FOR MOUNTING REMOTE CONTROLLED LIGHTING LTD TO RECESSED 2 CIRCUIT DMX DATA ENABLED TRACK. ENTIRE TRACK ASSEMBELY TO HAVE WHITE FINISH. DR8 27 VA WHITE LED; 20W; 4000K CCT; 80+ CRI; 4 SCDM MAX 120 V L6C SURFACE MOUNTED TRACK RCL EURTRAC 40 VA NONE 120 V L7 LINEAR WHITE LED WITH MEDIUM 50°X70° OPTICS, WHITE FINISH, LOCKABLE ROTATABLE SURFACE MOUNT, 16 BIT DMX DIMMABLE TO 1%, DMX ADRESSIBLE BY 1FT SEGMENTS, INTEGRAL DRIVER AND END TO END CONNECTORS. COLOR KINETICS eW COVE MX PRECISION DIM LUMENPULSE LUMENFACADE INTERIOR 50 VA 120 V L8 LINEAR WHITE LED WITH 30°X60° OPTICS, WHITE FINISH, LOCKABLE ROTATABLE SURFACE MOUNT, 16 BIT DMX DIMMABLE TO 1%, DMX ADRESSIBLE BY 1FT SEGMENTS, INTEGRAL DRIVER AND END TO END CONNECTORS. COLOR KINETICS EW FUSE PRECISION DIM LUMENPULSE LUMENFACADE INTERIOR 50 VA L9 LINEAR RGB LED WITH MEDIUM 50°X70° OPTICS, WHITE FINISH, LOCKABLE ROTATABLE SURFACE MOUNT, 16 BIT DMX DIMMABLE TO 1%, DMX ADRESSIBLE BY 1FT SEGMENTS, INTEGRAL DRIVER AND END TO END CONNECTORS. COLOR KINETICS iCOLOR COVE MX LUMENPULSE LUMENFACADE INTERIOR 50 VA WHITE LED; MIN 700 LUMENS/FT; 4000K CCT; 80+CRI; MAX 4 SDCM WHITE LED; MIN 700 LUMENS/FT; 4000K CCT; 80+CRI; MAX 4 SDCM MIN 400 LUMENS/FT RGB LED ARRAY L10 LINEAR RGB LED WITH 30°X60° OPTICS, WHITE FINISH, LOCKABLE ROTATABLE SURFACE MOUNT, 16 BIT DMX DIMMABLE TO 1%, DMX ADRESSIBLE BY 1FT SEGMENTS, INTEGRAL DRIVER AND END TO END CONNECTORS. COLOR KINETICS iCOLOR FUSE LUMENPULSE LUMENFACADE INTERIOR 50 VA L11 2" APERTURE LED DOWNLIGHT WITH 40° OPTIC, NON-IC MOUNTING TRAY, ALUMINUM HEAT SINK, 4" APERTURE MATTE WHITE POWDERCOAT PAINTED FLUSH TRIM PLATE WITH SPACKLE FLANGE FOR TRIMLESS INSTALLATION, 1" REGRESSED DIE CAST BLACK BAFFLE, SOFT FOCUS LENS AND INTEGRAL DRIVER SAME AS L11 BUT 4000K LED MODULE, IC HOUSING AND 60° OPTICS LUCIFER DL1ZP-LEDX 14 VA LUCIFER DL1ZP-LEDX 14 VA LUCIFER DL9ZP LEDX 14 VA L11A L11B L12 SAME AS L11 BUT WITH 4000K CCT MODULE, IC HOUSING, 60° OPTICS, AND WET LISTED TRIM RECTANGULAR MIRROR WITH IMBEDDED T5 FLUORESCENT LIGHTING TECH LIGHTING TL REFLECTION MIRROR 14 VA L13 LINEAR LED COVE FIXTURE WITH 60°X110° BEAM ANGLE, LOCKABLE ROTATABLE SURFACE MOUNT, MOUNTING TRACK, END TO END CONNECTORS, AND INTEGRAL DRIVER COLOR KINETICS eW COVE QLX MEDIUM BEAM LUMENPULSE LUMENCOVE L14 LINEAR WHITE LED WITH WIDE 110°X110° OPTICS, WHITE FINISH, FIXED SURFACE MOUNT, MOUNTING TRACK, 16 BIT DMX DIMMABLE TO 1%, DMX ADDRESSIBLE BY 12" LENGTH, INTEGRAL DRIVER AND END TO END CONNECTORS. COLOR KINETICS eW COVE MX PRECISION DIM LUMENPULSE LUMENCOVE HO L16 3.5" APERTURE LED DOWNLIGHT WITH 10° OPTIC, DIE CAST 1" REGRESSED BEVEL WITH WHITE PAINTED FLANGE, SOLITE LENS, INTEGRAL 0-10V DIMMING DRIVER L17 LED TASK LIGHT WITH 18" ADJUSTABLE GOOSENECK, SWITCH LOCATED IN BASE, CAST WEIGHTED BASE, RUBBER FOOTINGS, POWER CABLE AND 120V RECEPTACLE REMOTE POWER SUPPLY. L22 EXTERIOR RGB LED FLOOD FIXTURE WITH IP 66 RATING, WHITE FINISH, ALUMINUM HOUSING, 86°SPREAD LENS, INTEGRAL DMX DRIVER AND SURFACE MOUNTED TO POURED CONCRETE FOOTER USAI BEVELED 2.0 LITTLIGHT L-18-LED COLOR KINETICS COLOR BLAST KURT VERSEN A1137-10-40-27-70D1-WHT ECOSENSE LINEAR INT 6 VA 14 VA KIRLIN LRR-04002-39-41KSPT-XX 16 VA 27 VA 50 VA 120 V COMMENTS PROVIDE ALL NECESSARY ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. PROVIDE 18" WHITE SAFETY CABLE WITH 5/16" SPRINGHOOK, MOUNTING BRACKET AND C-CLAMP. ALL MOUNTING HARDWARE AND CABLES TO BE WHITE. DMX CONSOLE PROVIDED BY OTHERS. C-CLAMP PROVIDE ALL NECESSARY ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. PROVIDE 18" WHITE SAFETY CABLE WITH 5/16" SPRINGHOOK, MOUNTING BRACKET AND C-CLAMP. ALL MOUNTING HARDWARE AND CABLES TO BE WHITE. DMX CONSOLE PROVIDED BY OTHERS. SURFACE MOUNT PROVIDE ALL NECESSARY ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. PROVIDE 18" WHITE SAFETY CABLE WITH 5/16" SPRINGHOOK AND MOUNTING BRACKET. ALL MOUNTING HARDWARE AND CABLES TO BE WHITE. DMX CONSOLE PROVIDED BY OTHERS. SURFACE PROVIDE APPROPRIATE QUANTITY OF 1' AND 4' FIXTURES TO FILL ENTIRE FIXTURE RUN. PROVIDE ALL NECESSARY DATA BOXES, ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. ALL VISIBLE DATA BOXES, MOUNTING HARDWARE AND CABLES TO BE WHITE. DMX CONTROL CONSOLE PROVIDED BY OTHERS. C CLAMP PROVIDE ALL NECESSARY ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. PROVIDE 18" WHITE SAFETY CABLE WITH 5/16" SPRINGHOOK AND C-CLAMP. ALL MOUNTING HARDWARE AND CABLES TO BE WHITE. DMX CONSOLE PROVIDED BY OTHERS. PROVIDE WIDE SNOOT ACCESSORY. PROVIDE A TOTAL OF 20 DIFFUSE LENS ACCESSORIES. PROVIDE A TOTAL OF 20 CUSTOM GLASS LENS HOLDERS THAT CAN ACCEPT COLORED THEATRICAL GEL FILTERS. TRACK MOUNTED PROVIDE ALL NECESSARY ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. PROVIDE SHOP DRAWINGS SHOWING LENGTH AND CURVATURE OF TRACK SECTION PRIOR TO FINAL APPROVAL. SEE ARCHITECTURAL DRAWINGS FOR EXACT TRACK RUN LENGTHS. TRACK MOUNTED PROVIDE ALL NECESSARY ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. PROVIDE SHOP DRAWINGS SHOWING LENGTH AND CURVATURE OF RECESSED TRACK SECTION PRIOR TO FINAL APPROVAL. SEE ARCHITECTURAL DRAWINGS FOR EXACT TRACK RUN LENGTHS. TRACK USED FOR STORAGE OF UNUSED L6, L6A AND L6B FIXTURES. NO POWER REQUIRED, DO NO CIRCUIT. SURFACE PROVIDE MINIMUM QUANTITY OF 1' AND 4' FIXTURES TO FILL ENTIRE FIXTURE RUN. PROVIDE ALL NECESSARY DATA BOXES, ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. PROVIDE 3" JUMPER CABLE BETWEEN FIXTURES. 120 V SURFACE PROVIDE MINIMUM QUANTITY OF 1' AND 4' FIXTURES TO FILL ENTIRE FIXTURE RUN. PROVIDE ALL NECESSARY DATA BOXES, ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. 120 V SURFACE MIN 400 LUMENS/FT RGB LED ARRAY 120 V SURFACE PROVIDE MINIMUM QUANTITY OF 1' AND 4' FIXTURES TO FILL ENTIRE FIXTURE RUN. PROVIDE ALL NECESSARY DATA BOXES, ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. PROVIDE MINIMUM QUANTITY OF 1' AND 4' FIXTURES TO FILL ENTIRE FIXTURE RUN. PROVIDE ALL NECESSARY DATA BOXES, ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. WHITE LED; 720 LUMENS; 3000K CCT; 80+CRI; MAX 4 SDCM WHITE LED; 720 LUMENS; 4000K CCT; 80+CRI; MAX 4 SDCM WHITE LED; 720 LUMENS; 4000K CCT; 80+CRI; MAX 4 SDCM 14W T5; 3000K CCT; 80+ CRI 120 V RECESSED 120 V RECESSED 120 V RECESSED WHITE LED; MIN 240 LUMENS/FT; 3000K CCT; 80+CRI; MAX 4 SDCM WHITE LED; MIN 700 LUMENS/FT; 4000K CCT; 80+ CRI; 4 SDCM MAX WHITE LED; MIN 1000 LUMENS; 4000K CCT; 80+CRI; MAX 4 SDCM WHITE LED; 20W; 4000K CCT; 80+ CRI; 4 SCDM MAX MIN 1400 LUMENS; RGB LED ARRAY SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES NO. 120 V SURFACE 120 V SURFACE 120 V SURFACE PROVIDE SPECIALFX LIGHTING FADE-NOT POLYSLEEVE NEUTRAL DENSITY FILTER FOR EACH LAMP. PROVIDE SAMPLES OF 2' T5 FADE-NOT POLY SLEEVES IN COLOR OPTIONS ROSCO N.15 #3415, ROSCO N.3 #3402, ROSCO N.6 #3403 AND ROSCOSUN N.9 #3404 FOR ON-SITE MOCKUP. FINAL FADE-NOT POLY SLEEVE COLOR SPECIFICATION TO BE DETERMINED AFTER ON-SITE MOCKUP. COORDINATE MOCKUP WITH LIGHTING DESIGNER. PROVIDE ALL NECESSARY DATA BOXES, ACCESSORIES AND CONNECTORS FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE. CONSOLE PROVIDED BY OTHERS. RECESSED PROVIDE 15% DIMMING DRIVER AND ALL NECESSARY CONNECTORS AND ACCESSORIES FOR INTEGRATION WITH DMX THEATRICAL LIGHTING CONSOLE 120 V SURFACE PROVIDE CAST WEIGHTED BASE ACESSORY WITH RUBBER FOOTINGS. FIXTURE SHALL NOT BE PERMANENTLY MOUNTED TO DESK. SURFACE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY 120 V 120 V PROJECT ARCH/ ENGR APPROVAL DATE SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com PROVIDE ALL NECESSARY CONTROL EQUIPMENT AND CONNECTORS FOR INTEGRATION WITH THEATRICAL LIGHTING CONSOLE Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: LIGHT FIXTURE SCHEDULE WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE DATE 22MAY13 FILE PLOT DATE STAMP E0−003 5/21/2013 12:15:47 PM WFG JOB NO. − SHEET NO. SHEET NOTES 1 39 36 2 A. 40 38 3 B. C. D. 35 37 4 E. 5 F. G. H. P-9B 6 P-9A ED13 34 AIR COMP ED13 E1-12 I. ED13 ED13 J. EF-8 P-5A ED13 MECHANICAL EQUIPMENT ROOM UP P-5B P-6B ED13 MECHANICAL EQUIPMENT ROOM P-6A K. 7 UH-4 UP ED13 002 L. ED21 001 ED21 UH ED13 M. 33 SF-1 ED13 N. 8 SF-2 ED13 CP FA DN ED12 REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS SPARES FOR NEW WORK. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT SPECIFICALLY INDICATED RECYCLE OR DISPOSE MATERIALS OFF SITE OR IN COMPLIANCE WITH OWNER POLICY AND INCLUDE ALL COSTS IN BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS, ALL FEDERAL, STATE, AND LOCAL REGULATIONS, PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT EXISTING WALLS REMAIN INTACT. WHERE EXISTING BUILDING SERVICES AND/OR EQUIPMENT THAT IS TO REMAIN IN USE ARE REQUIRED TO BE SHUT DOWN COORDINATE WITH THE OWNER'S REPRESENTATIVE. , INCLUDE ALL ASSOCIATED OVERTIME COSTS TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT DOWN. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS ALTERATION. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED LINES OR INDICATED WITH KEYNOTES. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TOREMAIN UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND SYSTEMS IN CEILING SPACES. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM DEVICES THAT ARE TO REMAIN. EXISTING FIRE ALARM NOTIFICATION APPLIANCES AND INITIATION DEVICES (AND ASSOCIATED WIRING AND CONDUIT) SHALL BE REMOVED UNLESS NOTED OTHERWISE. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL REMOVED EQUIPMENT AND DEVICES. OWNER WISHES TO SALVAGE SELECT EQUIPMENT AS HISTORIAL RELICS. COORDINATE WITH OWNER PRIOR TO DISPOSAL OF ANY EQUIPMENT. DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES ED13 MECHANICAL CONTROLS (E)EF-6 32 LDP-1 T-B-11 LP-B-8 KEYED NOTES PDP-1 9 T ED12 REMOVE EXISTING FIRE ALARM CONTROL PANEL. UPON COMPLETION OF DEMOLITION, EXTEND EXISTING TO REMAIN FIRE ALARM CIRCUITS TO NEW FIRE ALARM CONTROL PANEL IN SAME LOCATION. ED13 REMOVE CIRCUIT (CONDUIT, WIRING, DISCONNECT, STARTER, ETC...) FEEDING MECHANICAL EQUIPMENT BACK TO SOURCE. COORDINATE WITH MECHANICAL PLANS AND TRADES. ED15 REFER TO DEMOLITION ELECTRICAL ONE LINE DIAGRAM FOR DETAILS REGARDING REMOVAL OF EXISTING ELECTRICAL EQUIPMENT. REMOVE AND REPLACE EXISTING CARD READER. REUSE EXISTING CONDUIT AND WIRING. VERIFY EXACT LOCATION IN FIELD. EXTEND CIRCUIT (CONDUIT AND WIRING) TO NEW SECURITY PANEL LOCATED IN FIRST FLOOR STORAGE 127D. ATS LP-B-8E LDP-2 SUB 6B TRANSFORMER ROOM T-B-8 T 31 ELEVATOR CONTROL PANEL 10 003 ED16 SUB 6A ED26 ED21 30 11 ED26 ELEVATOR DISCONNECT EXISITNG ELEVATOR MOTOR AND CONTROLS AS REQUIRED FOR MECHANICAL RELACEMENT/RESTORATION. RECONNECT UPON COMPLETION OF REPLACEMENT/RESTORATION. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL CONTRACTOR. NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY UP 12 STAIR LOBBY 29 ED26 REVISE EXISTING LIGHT FIXTURE LAYOUT TO ACCOMMODATE NEW MECHANICAL WORK WITHIN THIS SPACE. EXTEND LIGHTING CIRCUIT (CONDUIT AND WIRING) AS REQUIRED FOR NEW LAYOUT. 007 SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO CR ED16 SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com CR IN ELEVATOR ED16 CR ELEVATOR 008 ED16 28 TUNNEL #5 13 005 Worldwide Facilities Group ED16 CR General Motors Corporation SDP-1 T-COM CABINET PROJECTION SCREEN Warren Technical Center Campus TURN TABLE CONTROL PANEL ED13 27 ED15 HV-1 Site ID: 1563 14 Structure ID: 4235 TUNNEL #6 Level: 006 STORAGE ROOM 15 004 BASEMENT FLOOR ELECTRICAL DEMOLITION PLAN 26 WFG PE/PM WFG JOB NO N. WEINGARTZ 16 DRAWN BY 1200912 SHEET NUMBER Author SCALE 25 24 23 22 21 20 19 18 17 1/8" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP ED1−200 5/21/2013 12:15:54 PM WFG JOB NO. − SHEET NO. SHEET NOTES A. 1 39 36 2 40 38 B. 3 C. D. 37 E. 4 JC 122 DC DC DC STAIR DC BASEBOARD HEATER MEN'S WASH ROOM BOARDROOM BASEBOARD HEATER ED09 JC 102 UP SUB-PANEL UP H. 104 126 F MEN'S TOILET G. WOMEN'S WASH 103 ROOM STAIR 121 35 6 WOMEN'S TOILET ED06 BOARDROOM DIMMING PANEL 120 F. 5 125 ED18 105 F I. EM 34 J. EM MECH EQUIP ROOM ED08 K. ED08 119 DN EF EF ED13 UP L. UP 106 ED13 UH 7 MECH EQUIP DN ROOM ED13 M. N. 33 8 BASEBOARD HEATER ED13 BASEBOARD HEATER ED10 SEC COAT ROOM ED08 101 ED18 DN HC CCTV CR 31 ED16 10 ED17 ED14 ON FACE OF CANOPY ED14 LOBBY CCTV F 116 F ED17 ENTRY ENTRY 117 109 ED02 LOBBY ON FACE OF CANOPY CCTV 108 ED17 ED17 ED16 CCTV HC ED23 ED23 CR CHAIR STORAGE RM F ED17 ED16 HC CCTV CR F 30 11 UNDERSIDE OF CANOPY 111 LOAD CENTER FA-BP11A (TO REMAIN) 29 MULTI-PURPOSE ROOM ED18 DN STAIR LOBBY 110 12 ED15 115 FA-BP11 CR ED16 ELEVATOR 124 CR ED16 ED15 28 CORRIDOR FA-BL14 DN DN SERVICE ENTRY 112 F ED07 13 ED19 114 STAGE DIMMER CONTROL PANEL ED07 ED22 F F F ED19 DC PLATFORM DC ED16 113 DN 14 CR 27 22MAY13 BIDS SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES ED08 REMOVE LIGHT FIXTURES, LIGHT SWITCHES, ELECTRICAL FIXTURES, TELECOM OUTLETS, FIRE ALARM DEVICES, AND ASSOCIATED CONDUIT AND WIRES (BACK TO SOURCE OR NEAREST UPSTREAM DEVICE THAT IS TO REMAIN) WITHIN THIS AREA U.O.N.. CONDUIT AND WIRES PASSING THROUGH THIS AREA SHALL REMAIN OR BE REROUTED AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. REFER TO MECHANICAL DEMOLITION PLANS AND REMOVE POWER CONNECTIONS TO MECHANICAL EQUIPMENT BACK TO SOURCE AS REQUIRED. ED09 REMOVE EXISTING SUB-PANEL AND FEEDER (CONDUIT AND WIRING) BACK TO SOURCE. UPON COMPLETION OF DEMOLITION EXTEND EXISTINGTO REMAIN BRANCH CIRCUITS (CONDUIT AND WIRING) TO NEW PROJECTION ROOM PANEL OF SAME VOLTAGE LOCATED ON MEZZANINE ABOVE AS REQUIRED. ED10 REMOVE EXISTING SECURITY PANEL. EXTEND EXISTING TO REMAIN POWER AND SECURITY CIRCUITS TO NEW SECURITY PANELS LOCATED IN FIRST FLOOR STORAGE 102J. REFER TO NEW POWER AND AUXILIARY SYSTEMS PLANS FOR NEW LOCATION. ED13 REMOVE CIRCUIT (CONDUIT, WIRING, DISCONNECT, STARTER, ETC...) FEEDING MECHANICAL EQUIPMENT BACK TO SOURCE. COORDINATE WITH MECHANICAL PLANS AND TRADES. DC ED17 HC FA-BL13 DISPLAY AREA DC CCTV CR 9 ED15 F UNDERSIDE OF CANOPY SEC ED15 FA-BL12 ED16 DEPT. MGR/SUPR APPROVAL ED02 REMOVE LIGHT FIXTURES FROM COVE. REMOVE CONDUIT AND WIRING BACK TO SOURCE. ED06 REMOVE CURTAIN CONTROLS FROM DIMMING PANEL THAT IS TO BE DEMOLISHED AND REINSTALL IN LOCATION INDICATED. ED07 REMOVE STAGE DIMMER CONTROL PANEL. OWNER TO PROVIDE NEW WIRELESS CONTROLS TO REPLACE INTEGRAL TURN TABLE CONTROLS. COORDINATE RELOCATION OF NEW TURN TABLE CONTROLS TO EXTERIOR OF BUILDING WITH OWNER DURING CONSTRUCTION. ED10 ED20 118 PROJECT ARCH/ ENGR APPROVAL ISSUED FOR KEYED NOTES ED13 32 REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS SPARES FOR NEW WORK. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT SPECIFICALLY INDICATED RECYCLE OR DISPOSE MATERIALS OFF SITE OR IN COMPLIANCE WITH OWNER POLICY AND INCLUDE ALL COSTS IN BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS, ALL FEDERAL, STATE, AND LOCAL REGULATIONS, PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT EXISTING WALLS REMAIN INTACT. WHERE EXISTING BUILDING SERVICES AND/OR EQUIPMENT THAT IS TO REMAIN IN USE ARE REQUIRED TO BE SHUT DOWN COORDINATE WITH THE OWNER'S REPRESENTATIVE. , INCLUDE ALL ASSOCIATED OVERTIME COSTS TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT DOWN. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS ALTERATION. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED LINES OR INDICATED WITH KEYNOTES. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TOREMAIN UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND SYSTEMS IN CEILING SPACES. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM DEVICES THAT ARE TO REMAIN. EXISTING FIRE ALARM NOTIFICATION APPLIANCES AND INITIATION DEVICES (AND ASSOCIATED WIRING AND CONDUIT) SHALL BE REMOVED UNLESS NOTED OTHERWISE. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL REMOVED EQUIPMENT AND DEVICES. OWNER WISHES TO SALVAGE SELECT EQUIPMENT AS HISTORIAL RELICS. COORDINATE WITH OWNER PRIOR TO DISPOSAL OF ANY EQUIPMENT. DATE 15 ED14 REMOVE EXISTING CEILING MOUNTED LIGHT FIXTURES WITHIN THIS ROOM. OTHER ELECTRICAL DEVICES LOCATED WITHIN ROOM TO REMAIN UNLESS NOTED OTHERWISE. NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E 16 FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com ED17 REMOVE AND REPLACE EXISTING CAMERA. REROUTE EXISTING CONDUIT WHERE EXISTING CONDUIT IS EXPOSED, OTHERWISE REUSE. PROVIDE NEW WIRING PER SPECIFICATIONS. VERIFY EXACT LOCATION IN FIELD. Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: ED19 REMOVE AND REPLACE EXISTING SECURITY DEVICE AND ASSOCIATED CIRCUIT BACK TO PANEL OR NEAREST UPSTRAM DEVICE TO REMAIN. VERIFY EXACT LOCATION IN FIELD. ED22 RELOCATE EXISTING TO REMAIN CABLES AND CONDUITS PASSING THROUGH PANEL LOCATION THAT ARE SERVING OTHER AREAS AS REQUIRED. COORDINATE NEW ROUTING WITH OWNER PRIOR TO INSTALLATION. CAREFULLY REMOVE FIBER OPTIC CABLE CONNECTED TO EXISTING CONTROL AREA AND TURN OVER TO OWNER. 26 CERTIFIED BY SUPPLIER PROJECT NO. ED20 EXISTING WIRELESS ACCESS POINT TO REMAIN. TEMPORARILY SUPPORT FROM STRUCTURE DURING DEMOLITION AND REINSTALL IN SAME LOCATION UPON COMPLETION OF NEW CONSTRUCTION. DN DEPT. MGR/SUPR APPROVAL R E V I S I O N S ED15 REFER TO DEMOLITION ELECTRICAL ONE LINE DIAGRAM FOR DETAILS REGARDING REMOVAL OF EXISTING ELECTRICAL EQUIPMENT. ED16 REMOVE AND REPLACE EXISTING CARD READER. REUSE EXISTING CONDUIT AND WIRING. VERIFY EXACT LOCATION IN FIELD. EXTEND CIRCUIT (CONDUIT AND WIRING) TO NEW SECURITY PANEL LOCATED IN FIRST FLOOR STORAGE 127D. ED18 REMOVE LIGHT FIXTURES, LIGHT SWITCHES, FIRE ALARM DEVICES, AND ASSOCIATED CONDUIT AND WIRES (BACK TO SOURCE OR NEAREST UPSTREAM DEVICE THAT IS TO REMAIN) WITHIN THIS AREA U.O.N.. REMOVE WIRING DEVICES AND TELCOMMUNICATIONS EQUIPMENT ONLY ON WALLS THAT ARE TO BE DEMOLISHED U.O.N.. CONDUIT AND WIRES PASSING THROUGH THIS AREA SHALL REMAIN OR BE REROUTED AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. REFER TO MECHANICAL DEMOLITION PLANS AND REMOVE POWER CONNECTIONS TO MECHANICAL EQUIPMENT BACK TO SOURCE AS REQUIRED. EXISTING RECEPTACLES AND TLECOMMUNICATIONS OUTLETS TO REMAIN. EXTEND CIRCUITS TO NEW PANEL AS REQUIRED. PROJECT ARCH/ ENGR APPROVAL DATE ED23 REMOVE EXISTING POWER AND LIGHTING CABLES DRAPED OVER FLOOR AND STEPS IN THIS AREA. REVISE CIRCUITING AS REQUIRED FOR EXISTING TO REMIAN UPSTREAM/DOWNSTREAM DEVICES. FIRST FLOOR ELECTRICAL DEMOLITION PLAN WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 1/8" = 1'-0" DATE 25 24 23 22 21 20 19 18 17 22MAY13 FILE PLOT DATE STAMP ED1−201 5/21/2013 12:15:59 PM WFG JOB NO. − SHEET NO. SHEET NOTES A. 1 39 36 2 40 38 B. 3 C. D. 37 E. 4 A/V MACHINE ROOM (E) I/T RACK SUB-PANEL 201 ED25 ED24 ED21 DN F. 5 G. ED05 PROJECTION ROOM PANEL H. DN ED15 35 6 UP EM EM MECH EQUIP ROOM 34 F 203 DN ED02 ED21 UP F I. MECH EQUIP ROOM ED21 J. 202 K. MCC-21 MCC-22 ED15 ED15 ED11 7 ED15 ED15 FA-L21 FA-L22 UH M. DIMMER CABINET #22 DIMMER CABINET #21 UH ED13 ED15 L. DN DWH-1 ED13 FA-BL22 ED15 FA-BL22 N. 33 8 32 9 31 10 REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS SPARES FOR NEW WORK. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT SPECIFICALLY INDICATED RECYCLE OR DISPOSE MATERIALS OFF SITE OR IN COMPLIANCE WITH OWNER POLICY AND INCLUDE ALL COSTS IN BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS, ALL FEDERAL, STATE, AND LOCAL REGULATIONS, PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT EXISTING WALLS REMAIN INTACT. WHERE EXISTING BUILDING SERVICES AND/OR EQUIPMENT THAT IS TO REMAIN IN USE ARE REQUIRED TO BE SHUT DOWN COORDINATE WITH THE OWNER'S REPRESENTATIVE. , INCLUDE ALL ASSOCIATED OVERTIME COSTS TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT DOWN. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS ALTERATION. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED LINES OR INDICATED WITH KEYNOTES. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TOREMAIN UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND SYSTEMS IN CEILING SPACES. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM DEVICES THAT ARE TO REMAIN. EXISTING FIRE ALARM NOTIFICATION APPLIANCES AND INITIATION DEVICES (AND ASSOCIATED WIRING AND CONDUIT) SHALL BE REMOVED UNLESS NOTED OTHERWISE. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL REMOVED EQUIPMENT AND DEVICES. OWNER WISHES TO SALVAGE SELECT EQUIPMENT AS HISTORIAL RELICS. COORDINATE WITH OWNER PRIOR TO DISPOSAL OF ANY EQUIPMENT. DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES KEYED NOTES ED01 ED02 11 30 ED03 ED01 ED04 UP ED05 12 29 13 28 ED11 REMOVE CIRCUIT (CONDUIT, WIRING, DISCONNECT, STARTER, ETC...) FEEDING MECHANICAL EQUIPMENT BACK TO SOURCE. COORDINATE WITH MECHANICAL PLANS AND TRADES. ED15 REFER TO DEMOLITION ELECTRICAL ONE LINE DIAGRAM FOR DETAILS REGARDING REMOVAL OF EXISTING ELECTRICAL EQUIPMENT. REVISE EXISTING LIGHT FIXTURE LAYOUT TO ACCOMMODATE NEW MECHANICAL WORK WITHIN THIS SPACE. EXTEND LIGHTING CIRCUIT (CONDUIT AND WIRING) AS REQUIRED FOR NEW LAYOUT. ED21 ED24 ED25 ED03 14 ED03 27 REMOVE SPOT LIGHT FIXTURES FROM UNDERSIDE OF RIM. REMOVE CONDUIT AND WIRING BACK TO SOURCE. REMOVE DEAD DISTRIBUTION PANEL. PANEL FEEDER HAS ALREADY BEEN REMOVED. REMOVE CONDUIT BACK TO SOURCE. DISCONNECT DOMESTIC WATER HEATER 'DWH-1' AND ASSOCIATED RECIRCULATION PUMP AND RELOCATE (R) AS INDICATED ON NEW MEZZANINE POWER PLAN. COORDINATE EXACT LOCATION IN FIELD WITH MECHANICAL TRADES. ED13 ED04 (TYP.) REMOVE LIGHT FIXTURES FROM SUSPENDED RING. REMOVE CONDUIT AND WIRING BACK TO SOURCE. REMOVE LIGHT FIXTURES FROM COVE. REMOVE CONDUIT AND WIRING BACK TO SOURCE. REMOVE SPOT LIGHT FIXTURES AND EMERGENCY LIGHT FIXTURE FROM PROJECTION AREA ABOVE AND TRACK LIGHT FIXTURES ILLUMINATING STAGE. REMOVE CONDUIT AND WIRING BACK TO SOURCE. NO. DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Worldwide Facilities Group REMOVE ABANDONED CONDUCTORS, CUT AND CAP UNUSED CONDUITS PENTRATING A/V MACHINE ROOM FLOOR LEVEL WITH FLOOR UPON COMPLETION OF DEMOLITION. REMOVE ALL ABANDONED LIGHTING CONTROL PANELS, LIGHTING EQUIPMENT, ETC... WITHIN THIS SPACE. REMOVE ASSOCIATED CONDUCTORS AND CONDUITS BACK TO SOURCE. U.O.N.. PROJECT ARCH/ ENGR APPROVAL DATE General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 (TYP.) Level: 15 MEZZANINE FLOOR ELECTRICAL DEMOLITION PLAN ED02 26 WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author 16 SCALE 1/8" = 1'-0" 25 24 23 22 21 20 19 18 17 DATE 22MAY13 FILE PLOT DATE STAMP ED1−202 5/21/2013 12:16:03 PM WFG JOB NO. − SHEET NO. SHEET NOTES PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS A. 1 39 36 2 40 38 REMOVE EXISTING ELECTRICAL DEVICES, EQUIPMENT, BRANCH CIRCUITS AND FEEDERS IN THEIR ENTIRETY BACK TO THEIR POINT OF ORIGIN UNLESS OTHERWISE INDICATED. TURN OFF AND LABEL CIRCUIT BREAKERS AS SPARES FOR NEW WORK. B. QUANTITY AND LOCATION OF DEVICES SHOWN ON PLANS ARE APPROXIMATE. FIELD VERIFY DEVICES AND LOCATIONS. C. PROTECT EXISTING-TO-REMAIN CEILING, FLOORS, WALLS AND PANELS. D. SELECT DEMOLITION MAY BE REQUIRED FOR NEW CONSTRUCTION AND MAY NOT BE DELINEATED ON THIS DRAWING. CAREFULLY COORDINATE DEMOLITION WITH NEW CONSTRUCTION (PARTITION AND REFLECTED CEILING) PLANS TO VERIFY ACTUAL EXTENT OF DEMOLITION. E. EXAMINE THE DRAWINGS OF OTHER TRADES AND BE FAMILIAR WITH THE DEMOLITION REQUIRED BY OTHER TRADES. PERFORM INCIDENTAL ELECTRICAL DEMOLITION WORK AND/OR RELOCATION REQUIRED TO FACILITATE THE DEMOLITION WORK OF OTHER TRADES, WHETHER OR NOT SPECIFICALLY INDICATED F. RECYCLE OR DISPOSE MATERIALS OFF SITE OR IN COMPLIANCE WITH OWNER POLICY AND INCLUDE ALL COSTS IN BID. HANDLE ALL MATERIALS IN ACCORDANCE WITH LEED REQUIREMENTS, ALL FEDERAL, STATE, AND LOCAL REGULATIONS, G. PROVIDE BLANK COVER PLATES WHERE DEVICES ARE REMOVED BUT EXISTING WALLS REMAIN INTACT. H. WHERE EXISTING BUILDING SERVICES AND/OR ED15 REFER THAT TO DEMOLITION ONE EQUIPMENT IS TO REMAIN ELECTRICAL IN USE ARE REQUIRED LINE DIAGRAM FOR DETAILS TO BE SHUT DOWN COORDINATE WITHREGARDING THE OWNER'S REMOVAL OF, INCLUDE EXISTING REPRESENTATIVE. ALLELECTRICAL ASSOCIATED EQUIPMENT. OVERTIME COSTS TO PERFORM THIS WORK DURING WEEKENDS AND EVENINGS. INCLUDE ALL COSTS FOR PROVIDING TEMPORARY POWER WHERE SHUT DOWN MUST OCCUR FOR PERIODS LONGER THAN THESE HOURS. COORDINATE ELECTRICAL SHUT DOWNS WITH THE OWNER ONE WEEK PRIOR TO SHUT DOWN. I. PROVIDE NEW TYPED DIRECTORIES FOR PANELS AFFECTED BY THIS ALTERATION. J. REMOVE ELECTRICAL EQUIPMENT INDICATED WITH HEAVY WEIGHT DASHED LINES OR INDICATED WITH KEYNOTES. K. PROVIDE CODE-COMPLIANT SUPPORT TO EXISTING-TOREMAIN UNSUPPORTED CONDUITS AND BOXES WHERE CEILINGS ARE TO BE REMOVED. RE-ROUTE BRANCH CIRCUITS AND RELOCATE JUNCTION BOXES AS REQUIRED TO FACILITATE INSTALLATION OF NEW EQUIPMENT AND SYSTEMS IN CEILING SPACES. L. MAINTAIN ELECTRICAL SERVICE TO LIGHTING FIXTURES AND DEVICES THAT ARE TO REMAIN. EXTEND CONDUIT AND WIRE AS REQUIRED WHERE DEMOLITION WORK AFFECTS ELECTRICAL SERVICE TO DOWNSTREAM DEVICES THAT ARE TO REMAIN. M. EXISTING FIRE ALARM NOTIFICATION APPLIANCES AND INITIATION DEVICES (AND ASSOCIATED WIRING AND CONDUIT) SHALL BE REMOVED UNLESS NOTED OTHERWISE. N. OWNER HAS FIRST RIGHT OF REFUSAL FOR ALL REMOVED EQUIPMENT AND DEVICES. OWNER WISHES TO SALVAGE SELECT EQUIPMENT AS HISTORIAL RELICS. COORDINATE WITH OWNER PRIOR TO DISPOSAL OF ANY EQUIPMENT. DATE 3 37 4 5 35 6 34 7 33 8 32 SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES 9 KEYED NOTES ED15 31 REFER TO DEMOLITION ELECTRICAL ONE LINE DIAGRAM FOR DETAILS REGARDING REMOVAL OF EXISTING ELECTRICAL EQUIPMENT. 10 EXISTING 150KVA TRANSFORMER TO BE RELOCATED T LP-RING ED15 LTG CNTL DIMMING PANEL (E)EF-4 NO. 11 30 PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM 12 29 CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com 13 28 Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 14 27 Structure ID: 4235 Level: 15 UPPER MEZZANINE FLOOR ELECTRICAL DEMOLITION PLAN 26 WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author 16 SCALE 1/8" = 1'-0" 25 24 23 22 21 20 19 18 17 DATE 22MAY13 FILE PLOT DATE STAMP ED1−203 5/21/2013 12:16:05 PM − SHEET NO. KEYED NOTES BASEMENT SUBSTATION NO. 6A B-4 80E 6A-3 800AF 400AT 6A-4 6B-2 6B-3 DISCONNECT EXISTING 5HP SMOKE EXHAUST FAN (EF-4) FROM EXISTING MOTOR CONTROL CENTER. INTERCEPT AND EXTEND EXISTING CONDUCTORS TO NEW 480V PANELBOARD FA-L22 VIA NEW COMBINATION MOTOR STARTER. PROVIDE NEW MOTOR STARTER PER SPECIFICATIONS. ED503 REMOVE EXISTING PANEL. UPON COMPLETION OF DEMOLITION, REFFEED EXISTING TO REMAIN LOADS FROM NEW PANEL 'FABL-22'. EXTEND CIRCUIT (CONDUIT AND WIRING0 AS REQUIRED. REFER TO NEW ONE LINE DIAGRAM AND POWER AND AUXILIARY SYSTEMS PLANS FOR DETAILS AND LOCATION OF NEW PANEL. ED504 REMOVE EXISTING PANEL. UPON COMPLETION OF DEMOLITION, REFFEED EXISTING TO REMAIN LOADS FROM NEW PANEL 'LP-2'. REFER TO NEW POWER PLAN FOR PANEL LOCATION. ED505 DISCONNECT AND RELOCATE EXISTING 150KVA TRANSFORMER. REFEED TRANSFORMER FROM NEW PANEL AS INDICATED ON NEW ONE LINE DIAGRAM. REFER TO MEZZANINE LEVEL POWER PLANS FOR NEW LOCATION. 800AF TIE 1600AF 1000AT 800AF 600AT 800AF 800AT 480Y/277V 3PH,4W BUS SPARE SPARE SPARE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS NOT FOR CON STRU CTIO N 800AF 800AT SPACE 800AF DATE SITE/BUILDING PLAN & NORTH ARROW 6B-1 SPACE SPACE 800AF 800AT 1600AF 1200AT SPACE 6A-2 ED502 SUB 6B 750/1000 KVA 13.2KV-480Y/277V 1600AF 1200AT 6A-1 REMOVE EXISTING PANEL. UPON COMPLETION OF DEMOLITION, REFFEED EXISTING TO REMAIN LOADS FROM NEW PANEL OF SAME NAME TO BE INSTALLED IN APPROXIMATE SAME LOCATION. REFER TO NEW ONE LINE DIAGRAM AND POWER AND AUXILIARY SYSTEMS PLANS FOR DETAILS AND LOCATION OF NEW PANEL. 80E SUB 6A 750/1000 KVA 13.2KV-480Y/277V 480Y/277V 3PH,4W BUS ED501 BASEMENT SUBSTATION NO. 6B A-4 GM DISCLAIMER & TYPICAL NOTES 600A 480V 3P,3W T-B-11 300 KVA 480 ∆-208Y/120V 60A/3/45A 60A/3/40A 30A/3/20A ED501 ED501 FA-L22 DIM CAB #21 DIM CAB #22 LP-B-8 B-11 DOME 1ST FL J-CLOSET FA-BP11 ELEVATOR CONTROLLER ED501 ED501 1 1/2 HP HV-1 AUDITORIUM SPARE SPARE DIM CAB #1 FA-BL-2 FA-BP11 30A 10A 200A 200A 200A FA-BL-22 ED501 30A 30A 30A 200A 200A 200A 100A 100A 100A 100A 100A 200A 200A 200A 200A 200A 200A 100A 100A 400A 400A 400A 300A SPACE SPACE 200A 175A 200A FA-L21 NO. 1 1/2 HP EF-6 2 SPEED 22733.000 ED504 FA-B14 FA-BP11A DEPT. MGR/SUPR APPROVAL CERTIFIED BY SUPPLIER PROJECT NO. PROJ. PANEL T PROJECT ARCH/ ENGR APPROVAL DATE R E V I S I O N S ED503 SUPPLIER DRAWN BY TO TUNNEL ED501 ED501 FA-BL12 LP-B-8E SUPPLIER CHECKED BY FA-BL13 SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com MEZZANINE MCC-22 MEZZANINE Worldwide Facilities Group General Motors Corporation 200A 800A 800A MCC-21 200A 800A, 480V, 3PH, 4W 800A, 480V, 3PH, 4W 4 SPACES 11 SPACES Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 EF-7 UH#1 ? WEST AUDIT SF P6A P6B TOILET EF AIR KITCHEN EF COMPRESSOR SPARE SPARE Level: SPARE T-B-8 30 KVA 480V-208Y/120V SPACE ED501 SDP-1 SPACE FA-BL-21 SPACE SPARE ATS-1 100A SPACE 175A 1200A, 208Y/120V, 3PH, 4W 800A, 480V, 3PH, 3W SPACE 200A 800A, 480Y/277V, 3PH, 4W BASEMENT SPACE 125A MCC-1 BASEMENT SPACES 100A 800A, 480Y/277V, 3PH, 4W PDP-1 BASEMENT 200A LDP-2 125A BASEMENT PDP-PV MAIN FOUNTAIN VAULT 1000A LDP-1 100A WFG JOB NO. SPARE ED502 60A OUTLET UH-4 P-9B P-9A P5 ALT P-9 ALTERNATOR (E)EF-4 AUDITORIUM EXHAUST ED505 EAST AUDITORIUM P-5A P-5B TOILET ROOM EF-2 EF-3 DEMOLITION ELECTRICAL ONE−LINE DIAGRAM 150 KVA 480V-208Y/120V 3 PHASE 400A, 3PH ED501 WFG PE/PM 96 CKT "SENSOR" WFG JOB NO N. WEINGARTZ DRAWN BY LP-RING LIGHTING CONTROL DIMMING PANEL (RING LIGHTING) 1200912 SHEET NUMBER Author SCALE 12" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP ED6−511 5/21/2013 12:16:07 PM WFG JOB NO. − SHEET NO. ROOM LEGEND 1 39 36 2 40 38 001 002 003 004 005 006 007 008 3 DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS MECHANICAL EQUIPMENT ROOM MECHANICAL EQUIPMENT ROOM TRANSFORMER ROOM STORAGE ROOM TUNNEL #5 TUNNEL #6 STAIR LOBBY ELEVATOR 35 37 4 SHEET NOTES A. 5 B. C. NEW FA-BL21- 2 PC M 34 UH-6 TS PC WF E244 SAF-AHU-4 001 NEW FA-BL21- 4 D VF D VF SAF-AHU-3 E201 E201 VF D E. 6 CRU-1 HWP-2 VF D VF HWP-1 D NEW FA-L21- 7,9,11 RAF-AHU-4 UP NEW FA-L22- 8 SP-1 & 2 NEW FA-BL22- 9,11,13 NEW FA-L21- 8,10,12 D. TO MCC-1. REFER TO ONE LINE DIAGRAM FOR CIRCUITING DETAILS COORDINATE FINAL LOCATION OF MECHANICAL EQUIPMENT AND ASSOCIATED DISCONNECT SWITCHES, STARTERS, VFDS, CONTROL POWER AND OTHER POWER REQUIREMENTS WITH DIV 15. SURFACE MOUNTED RACEWAY SHALL NOT BE UTILIZED IN FINISHED AREAS WITHOUT ARCHITECT APPROVAL U.O.N. PROVIDE ALL NECESSARY CABLING FROM SECURITY DEVICES (CAMERAS, DOOR HARDWARE, ETC...) BACK TO NEW SECURITY PANELS. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW ELECTRICAL EQUIPMENT AND DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE SEPARATE ISOLATED GROUND CONDUCTOR FOR EACH CIRCUIT FED FROM ISOLATED GROUND PANEL 'LP-AV'. M E244 HU-1 VF D RAF-AHU-3 E201 (TYP.) E220 NEW FA-BL22- 1 LP-B-8- 22 KEYED NOTES RECEPTACLE FOR GLYCOL PUMP GLF-1 7 WF TS AHU LIGHTS UP E220 LP-B-8- 22 E204 AHU LIGHTS E204 E220 LP-B-8- 22 M UH-5 002 CHWP-2 LP-B-8E- 23 E220 CONNECT TO NEW 20A, 1 POLE CIRCUIT BREAKER IN PANELBOARD 'LP-B-8' LOCATED IN ADJACENT ELECTRICAL ROOM. CIRCUIT AS INDICATED. E230 DISCONNECT EXISTING 4' CHAIN HUNG INDUSTRIAL LIGHT FIXTURE INSIDE DOOR OF MECHANICAL/ELECTRICAL SPACE FROM EXISTING NORML CIRCUIT. CONNECT EXISTING FIXTURE TO SPARE 20A CIRCUIT BREAKER IN PANEL BOARD 'LP-B-8E'. FIXTUE SHALL FUNCTION AS NIGHTLIGHT. EXTEND EXISTING NORMAL CIRCUIT AS REQUIRED TO COMPLETE THE CIRCUIT. D VF D VF 30 E201 CP FA E204 PROVIDE ELECTRICAL CONNECTIONS BETWEEN AIR HANDLING UNIT SECTIONS DURING INSTALLATION AS REQUIRED. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL TRADES. DRY PIPE COMPRESSOR M CHWP-1 33 E201 COORDINATE EXACT VFD LOCATION WITH MECHANICAL PLANS AND MECHANICAL TRADES PRIOR TO INSTALLATION. PROVIDE INTERCONNECTING WIRING BETWEEN VFD AND MOTOR(S) AS REQUIRED. TO MCC-1. REFER TO ONE LINE DIAGRAM FOR CIRCUITING DETAILS 8 DN (TYP.) E230 75 (E)EF-6 32 LDP-1 T-B-11 LP-B-8 PDP-1 9 T ATS LP-B-8E SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES E244 PROVIDE 120V POWER AND DATA CONNECTION FOR NEW DDC CONTROLS DEVICES AS REQUIRED. COORDINATE LOCATION WITH MECHANICAL TRADES. PROVIDE POWER FROM NEAREST 120V PANELBOARD SERVING AREA. LDP-2 SUB 6B T-B-8 T 31 10 003 SUB 6A MCC-1 11 30 NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S ELEVATOR CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 75 SUPPLIER DRAWN BY UP SUPPLIER CHECKED BY 12 29 007 SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO CR F CR IN ELEVATOR CR 008 SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com 13 28 005 CR Worldwide Facilities Group NEW SPD-1 PROJECTION SCREEN General Motors Corporation 110 Warren Technical Center Campus Site ID: 1563 14 27 110 Structure ID: 4235 F ? Level: 006 15 004 BASEMENT FLOOR POWER AND AUXILIARY SYSTEMS PLAN 26 WFG PE/PM WFG JOB NO N. WEINGARTZ 16 25 24 23 22 21 20 19 18 17 DRAWN BY 1200912 SHEET NUMBER Author SCALE 1/8" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EP1−200 5/21/2013 12:16:40 PM WFG JOB NO. − SHEET NO. ROOM LEGEND 1 39 36 2 40 38 3 MOTORIZED SHADES E236 NEW FA-BL21- 42 37 125 E248 CR 101 102 103 104 105 106 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 124 125 126 127A 127B 127C 127D 4 E248 J CR DC P SD DC NEW FA-BL21-40 DC DC PSD NEW FA-BL21-40 NEW LP-AV- 63 FB1 5 126 E218 75 E231 J J 48" NEW FA-BL12-3 E206 15 CR F 15 DC 35 E249 E232 48" E218 NEW FA-BL21- 44 FB2 NEW FA-BL13-7 15 CR F 6 15 NEW FA-BL13-9 NEW LP-AV- 67 J 119 UP NEW FA-BL12- 2 E219 E235 E235 106 WF J 104 E219 TS NEW LP-M-1E- 6 C. UP TS D. NEW FA-BL13- 2 105 M M E219 NEW LP-AV- 71 NEW FA-BL13 C SE CR NEW LP-AV- 42 SEC SEC E219 DR E243 NEW LP-AV- 42 127B ELECTRICAL OUTLETS ON GREENROOM WALLS SHALL BE MOUNTED HORIZONTALLY IN BASE OF WALL U.O.N.. NEW FA-BL13- 3 NEW FA-BL13- 3 E243 NEW LP-AV- 38 E216 15 E206 NEW FA-BL13- 13 NEW LP-AV- 36 E224 E225 E219 BELOW STEPS NEW FA-BL12- 8 H E251 60" 30 E219 48" C1 NEW FA-BL12-4 E209 CCTV 108 E209 E233 E233 NEW LP-AV- 68 HC NEW FA-BL13- 10 J NEW LP-AV- 70 L6-30R CONNECT TO NEW 208V, 2P, 30A CIRCUIT BREAKER IN PANEL 'FA-BP11A' VIA NEW 208-230V, 2P, 5KVA BUCKBOOST TRANSFORMER. NEW FA-BL13-8 E224 L6-30R J C1 CCTV DC DC 30 E225 FEED VIA NEW 208-230V, 2P, 5KVA BUCKBOOST TRANSFORMER. E240 111 ON CANOPY FACE F 109 117 DC DC C2 116 F CCTV 10 NEW FA-BL13- 13 ELECTRICAL/DATA/AV OUTLETS ON THIS WALL SHALL BE MOUNTED HORIZONTALLY IN BASE OF WALL U.O.N.. (TYP.) 60" DC DC HC NEW FA-BL12- 8 48" E251 ELECTRICAL/DATA/AV OUTLETS ON THIS DN WALL SHALL BE MOUNTED HORIZONTALLY IN BASE OF WALL U.O.N.. NEW FA-BL13- 13 J J H J E237 HC H CR 40" K C2 HC CR CCTV J DC NEW FA-BL12- 6 101 E243 NEW LP-AV- 36 H H 30 DC ON FACE OF CANOPY E237 HC 31 40" CR H DC HC DC PSD CCTV K C1 CR J 60" 60" IWH-1 NEW FA-BL13- 4,6 DR 15 C1 11 UNDERSIDE OF CANOPY FAAP E203 DN 75 110 12 NEW FA-BP11 115 15 15 DN E233 J J CR E219 E219 J E232 114 NEW FA-BP11- 26,28 NEW LP-AV- 68 J E219 DN NEW LP-AV- 68 NEW LP-AV- 68 J J E233 L6-30R FEED VIA NEW 208-230V, 2P, 5KVA BUCK-BOOST TRANSFORMER. E232 E246 J NEW LP-AV- 70 MOUNT BELOW PLATFORM. CONNECT NEW DUPLEX RECEPTACLE TO EXISTING ADJACENT 120V RECEPTACLE CIRCUIT. 13 15 DC E246 CR DC DC 15 F J E219 J E219 NEW LP-AV- 70 NEW LP-AV- 70 CR J 113 D PS DC E247 CR NEW FA-BP11-24 14 J TV CC CC TV 15 C3 E223 C3 CCTV C3 26 16 25 24 23 22 21 20 19 18 17 E218 FLOORBOX 'FB1'. PROVIDE WIREMOLD CCBB 16"X12"X6"D SERIES. ROUTE (3) 1"C. BELOW SLAB TO A/V MACHINE ROOM. ROUTE 3/4"C BELOW SLAB TO ISOLATED GROUND PANEL 'LP-AV' FOR CIRCUITING AND 1"C. TO ACCESSIBLE CEILING SPACE FOR DATA. NO. DEPT. MGR/SUPR APPROVAL CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY E224 MOUNT DOOR ACTIVATION SWITCH ON STEEL COLUMN/MULLION. POWER/CONTROL CABLING SHALL BE ROUTED WITHIN COLUNM/MULLION. REFE RT OACCESS CONTROL DOOR DETAIL NO.3 ON ELECTRICAL DETAIL SHEET. SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com E233 PROVIDE 10"X10"X4"D JUNCTION BOX WITH (3)1"C. TO A/V MACHINE ROOM. PROVIDE (1) GM LAN CABLE/CONNECTION. COORDINATE EXACT LOCATION IN FIELD. E235 PROVIDE (2) SINGLE GANG JUNCTION BOXES, EACH WITH 1"C. TO A/V MACHINE ROOM. COORDINATE EXACT REQUIREMENTS WITH AV SYSTEM CONTRACTOR. COORDINATE LOCATION WITH ARCHITECTURAL PLANS. E238 PROVIDE ELECTRONIC HORN SECURITY NOTIFICATION APPLIANCE ON MULLION AT CEILING. E240 EXTEND EXISTING 208V, 30A, 2P CIRCUIT IN CHAIR STORAGE RM 111 TO FEED NEW RECEPTACLE INDICATED. E242 EXISTING POWER RECEPTACLES BELOW STEPS TO REMAIN. PROVIDE NEW DATA OUTLETS IN SAME LOCATION. E243 PROVIDE DESK TOP RECEPTACLE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH ARCHITECTURAL TRADES. SEE E0.1 SHEET FOR MODEL. E245 REFER TO ACCESS CONTROL DOOR DETAIL NO.6 ON ELECTRICAL DETAILS SHEET. E246 REFER TO ACCESS CONTROL DOOR DETAIL NO.4 ON ELECTRICAL DETAILS SHEET. E247 REFER TO ACCESS CONTROL DOOR DETAIL NO.5 ON ELECTRICAL DETAILS SHEET. E248 REFER TO ACCESS CONTROL DOOR DETAIL NO.1 ON ELECTRICAL DETAILS SHEET. E249 REFER TO ACCESS CONTROL DOOR DETAIL NO.8 ON ELECTRICAL DETAILS SHEET. E250 REFER TO ACCESS CONTROL DOOR DETAIL NO.7 ON ELECTRICAL DETAILS SHEET. E251 PROVIDE SINGLE GANG JUNCTION BOX WITH 1"C. TO A/V MACHINE ROOM. COORDINATE EXACT REQUIREMENTS WITH AV SYSTEM CONTRACTOR. COORDINATE LOCATION WITH ARCHITECTURAL PLANS. PROJECT ARCH/ ENGR APPROVAL DATE R E V I S I O N S E219 PROVIDE SINGLE GANG JUNCTION BOX WITH 1"C. TO A/V MACHINE ROOM. PROVIDE (1) GM LAN CABLE/CONNECTION. COORDINATE EXACT REQUIREMENTS WITH AV SYSTEM CONTRACTOR. COORDINATE LOCATION WITH ARCHITECTURAL PLANS. Worldwide Facilities Group E236 PROVIDE POWER AND CONTROLS CONNECTIONS FOR MOTORIZED SHADES. COORDINATE CONTROLS WITH AV SYSTEM CONTRACTOR. CIRCUIT AS INDICATED. E237 PROVIDE NEW BI-DIRECTIONAL SURFACE MOUNTED HANDICAP PUSHBUTTON CONTROL ON STEEL COLUMN/MULLION. POWER/CONTROL CABLING SHALL BE ROUTED WITHIN COLUNM/MULLION. 110 110 27 112 DC DC MOUNT BELOW PLATFORM. (TYP.) DC 28 124 DC E217 9.38"X10.85" BACKBOX FOR WALL MOUNTED AV TOUCH PANEL PROVIDED BY OTHERS WITH 3/4"C. TO A/V MACHINE ROOM AND 1/2"C. TO PROJECTION SCREEN FOR MOTORIZED SCREEN CONTROL. COORDINATE REQUIREMENTS WITH AV SYSTEM CONTRACTOR. COORDINATE LOCATION WITH ARCHITECTURAL PLANS. E225 REFER TO ACCESS CONTROL DOOR DETAIL NO.2 ON ELECTRICAL DETAILS SHEET. E231 PROVIDE SINGLE GANG JUNCTION BOX MOUNTED IN CEILING WITH 1/2"C. TO A/V MACHINE ROOM FOR WIRELESS ACCESS POINT. E232 PROVIDE SINGLE GANG JUNCTION BOX FOR PTZ CAMERA WITH 3/4"C. TO A/V MACHINE ROOM AND ADJACENT ISOLATED GROUND RECEPTACLE. COORDINATE EXACT LOCATION WITH AV CONTRACTOR. CR F DC CR E245 E216 PROVIDE BLACK 2-CHANNEL WIREMOLD V4000 SERIES STEEL RACEWAY BELOW DESKTOP FOR POWER/DATA. PROVIDE BLACK CABOFIL CFG 50/200 STEEL 'G' TRAY. REFER TO ARCHITECTURAL PLANS FOR MOUNTING LOCATION. SEGMENT RACEWAY/'G' TRAY AS REQUIRED FOR MOUNTING. CIRCUIT AS INDICATED. E223 PROVIDE SECURITY CAMERA ON ADJACENT DESIGN CENTER BUILDING ROOF. PROVIDE CONDUIT AND WIRING BACK TO SECOND FLOOR SECURITY CLOSET. COORDINATE EXACT MOUNTING LOCATION WITH OWNER PRIOR TO INSTALLATION. FA-BP11A 29 GM DISCLAIMER & TYPICAL NOTES E209 RECESS MOUNT FIRE ALARM PULL STATION BACKBOX WITHIN STEEL COLUMN. FIRE ALARM CABLING SHALL BE ROUTED WITHIN COLUNM. E211 PROVIDE (6) SINGLE GANG JUNCTION BOXES BELOW STEPS WITH 1"C. TO A/V MACHINE ROOM FOR A/V EQUIPMENT. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR. NEW FA-BL13- 5 CCTV E242 ER HEAT NEW LP-AV- 36 9 NEW FA-BL13- 5 DC DC DR E242 E250 NEW FA-BL13- 3 CR DC NEW LP-AV- 38 J 60" E219 60" NOT FOR CON STRU CTIO N E203 PROVIDE FIRE ALARM ANNUNCIATOR PANEL. COORDINATE EXACT LOCATION WITH OWNER PRIOR TO INSTALLATION. E206 PROVIDE SINGLE GANG JUNCTION BOX WITH 3/4"C. TO A/V MACHINE ROOM FOR LIGHTING CONTROL. COORDINATE EXACT REQUIREMENTS WITH AV SYSTEM CONTRACTOR. COORDINATE LOCATION WITH ARCHITECTURAL PLANS. NEW FA-BL13- 3 127C E242 30 UNDERSIDE OF CANOPY SITE/BUILDING PLAN & NORTH ARROW 127A NEW LP-AV- 40 E238 COORDINATE FINAL LOCATION OF MECHANICAL EQUIPMENT AND ASSOCIATED DISCONNECT SWITCHES, STARTERS, VFDS, CONTROL POWER AND OTHER POWER REQUIREMENTS WITH DIV 15. SURFACE MOUNTED RACEWAY SHALL NOT BE UTILIZED IN FINISHED AREAS WITHOUT ARCHITECT APPROVAL U.O.N. PROVIDE ALL NECESSARY CABLING FROM SECURITY DEVICES (CAMERAS, DOOR HARDWARE, ETC...) BACK TO NEW SECURITY PANELS. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW ELECTRICAL EQUIPMENT AND DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE SEPARATE ISOLATED GROUND CONDUCTOR FOR EACH CIRCUIT FED FROM ISOLATED GROUND PANEL 'LP-AV'. KEYED NOTES 8 E250 NEW LP-AV- 40 NEW FA-BL12 DISPLAY AREA BOARDROOM JC WOMEN'S WASH ROOM WOMEN'S TOILET MECH EQUIP ROOM LOBBY ENTRY STAIR LOBBY CHAIR STORAGE RM CORRIDOR PLATFORM SERVICE ENTRY MULTI-PURPOSE ROOM LOBBY ENTRY COAT ROOM MECH EQUIP ROOM MEN'S TOILET MEN'S WASH ROOM JC ELEVATOR STAIR STAIR COPY ROOM/CIRCULATION GREEN ROOM CLOSET SECURITY CLOSET J PROVIDE (3)2"C. BACK TO A/V MACHINE ROOM. SAWCUT FLOOR AS REQUIRED. REFER TO ARCHITECTURAL PLANS FOR DETAILS. J 118 J DC DC NEW LP-AV- 42 UH-1 32 22MAY13 BIDS UH-2 DC PSD 33 E. NEW FA-BL13- 1 M NEW FA-BL12- 1 B. 7 DN EF-1 M J NEW LP-AV- 71 DC DRY PIPE COMPRESSOR J J TS 121 M EF-2 NEW LP-AV- 71 NEW LP-AV- 69 J TS E211 NEW LP-AV- 69 DN A. 30 30 NEW LP-AV- 69 DEPT. MGR/SUPR APPROVAL NEW FA-BL13-7 NEW LP-AV- 67 120 PROJECT ARCH/ ENGR APPROVAL ISSUED FOR SHEET NOTES E232 122 NEW FA-BL12-3 E217 E249 (1)3/4"C, (1)1-1/4"C. (1)3/4"C, (1)1-1/4"C. J NEW FA-BL13-9 NEW LP-AV- 65 FB1 MOTORIZED SCREEN NEW LP-AV- 61 NEW FA-BL21- 44 FB2 ELTD NEW FA-BL12-5 34 UP 102 J NEW FA-BL12-5 DC UP DATE General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: FIRST FLOOR POWER AND AUXILIARY SYSTEMS PLAN WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 1/8" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EP1−201 5/21/2013 12:16:51 PM WFG JOB NO. − SHEET NO. ROOM LEGEND 1 39 36 201 202 203 2 40 38 4 PROVIDE RACK GROUNDING PROJECTOR LIFT E201 (R)DWH-1 35 NEW FA-BL21-6 RC-1 M CP-3 NEW FA-L21- 2,4,6 NEW FA-BL21- 11,13 J J NEW LP-M-1E NEW LP-AV J E215 1,3,5,7,9,11 2,4,6,8,74,76 E226 T 201 DN (TYP.) CP-1 M NEW FA-BL21- 6 T 30 NEW FA-BL22- 2 RC-2 B. RELOCATED T-LP-AV ATS-2 F M 30 J F UH-4 CP-4 M J C. GROUND BAR UP T0 (E)EF-4 E205 CP-2 NEW FA-L22- 1,3,5 SAF-AHU-2 E212 E213 MOTOIZED SCREEN NEW LP-AV- 72 DN NEW FA-BL21- 7 J J E214 J E211 J KEYED NOTES RAF-AHU-2 7 AHU LIGHTS NEW FA-BL22- 4 E204 J DN 185 185 NEW FA-BL22- 8 E202 FIRE ALARM DEVICE SHALL BE MOUNTED AT UNDERSIDE OF DOME RIM SOFFIT. COORDINATE EXACT LOCATION WITH LIGHT FIXTURES AND SPRINKLER HEADS MOUNTED ON SAME SURFACE. UH-3 NEW FA-BL21- 23 E204 E201 COORDINATE EXACT VFD LOCATION WITH MECHANICAL PLANS AND MECHANICAL TRADES PRIOR TO INSTALLATION. PROVIDE INTERCONNECTING WIRING BETWEEN VFD AND MOTOR(S) AS REQUIRED. NEW FA-BL22- 6 NEW FA-BL22- 8 NEW FA-BL21- 23 AHU LIGHTS E244 E201 E214 30 NEW FA-BL21- 8,10,12 33 E241 E241 3/4"C. TO A/V MACHINE ROOM J J TV CC NEW LP-AV- 30 NEW FA-BL22- 15,17,19 NEW LP-AV- 32 TV CC C2 C2 (TYP.) 32 9 NEW FA-BL22- 10 FPB-2 NEW FA-BL21- 15 DC 3/4"C. (TYP.) R1 E202 (TYP.) R2 CKTS 12,14,16 185 CKTS 21,23,25,27,29 E207 R1 NEW FA-BL21- 19 R1 NEW FA-BL22- 12 10 (TYP.) R2 R2 CKTS 24,26,28 E241 185 (TYP.) LP-RING-41 & 43 CKTS 2,4,6,8,10 31 E202 CKTS 11,13,15,17,19 CKTS 13,15,17 R1 R1 E241 J CKTS 31,33,35,37,39 NEW LP-AV- 32 NEW LP-AV- 30 CKTS 22,24,26,28,30 30 NEW FA-BL22- 12 CKTS 19,21,23 LP-RING-42 & 44 NEW FA-BL21- 19 R1 R2 E221 (TYP.) UP 11 CKTS 45,47,49,51,53 CKTS 32,34,36,38,40 CKTS 18,20,22 CKTS 46,48,50,52,54 R1 R1 E222 (TYP.) E221 (TYP.) NEW FA-BL22- 14 12 29 NEW FA-BL21- 17 3/4"C. (TYP.) NEW FA-BL22- 14 TV CC NEW FA-BL21- 17 E241 J J NEW LP-AV- 30 C2 CC TV C2 E241 13 NEW LP-AV- 32 28 185 120V CKTS 44,46,48,50 208V CKTS 52,54 & 56,58 & 60,62 & 64,66 185 NEW FA-BL22- 16 E214 NEW FA-BL21- 21 NEW LP-AV- 73 MOTORIZED SCREEN NEW LP-AV- 34 9 9 9 11 27 11 13 J J 13 15 15 15 NEW FA-BP11- 4 15 17 17 E227 17 19 25 27 27 27 27 25 14 23 NEW FA-BP11- 6 17 E227 NEW FA-BP11- 8 NEW FA-BP11- 12 NEW FA-BP11- 10 E227 3/4"C. (TYP.) 3/4"C. TO A/V MACHINE ROOM J J E227 J E227 NEW FA-BP11- 2 E210 J E210 E211 E227 NEW FA-BL22- 16 19 19 19 21 21 21 21 23 E228 (TYP.) NEW FA-BP11- 20 NEW FA-BP11- 14 15 NEW FA-BP11- 20 NEW FA-BP11- 14 NEW FA-BP11- 16 (TYP.) 26 NEW FA-BP11- 18 NEW FA-BP11- 16 16 NO. PROJECT ARCH/ ENGR APPROVAL DATE CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 E227 RECEPTACLE SHALL BE MOUNTED WITHIN UPPER MEZZANINE SPACE FOR TYPE 'L1' LIGHT FIXTURE POWER. COORDINATE EXACT LOCATION IN FIELD. CIRCUIT VIA LIGHTING RELAY PANEL TO CIRCUIT INDICATED. Structure ID: 4235 Level: E228 PROVIDE PERFORMANCE ELECTRIC MODEL# PPBD-2-520R (OR EQUAL BY OTHERS) PIPE MOUNTED BOX. MOUNT BOX WITH RECEPTACLE ORIENTED TOWARD CEILING. VERIFY COLOR CUSTOM REQUIREMENTS WITH ARCHITECT. DAISY CHAIN RECEPTACLE BOXES TO MINIMIZE CONDUIT RUNS. COORDINATE ROUTING WITH SGJJR ELECTRICAL ENGINEER. CIRCUIT NUMBERS SHOWN ARE FROM PANELBOARD 'FA-BP11' VIA RELAY PANEL. E244 PROVIDE 120V POWER AND DATA CONNECTION FOR NEW DDC CONTROLS DEVICES AS REQUIRED. COORDINATE LOCATION WITH MECHANICAL TRADES. PROVIDE POWER FROM NEAREST 120V PANELBOARD SERVING AREA. DEPT. MGR/SUPR APPROVAL R E V I S I O N S E222 TYPE 'R2' MULTI-OUTLET ASSEMBLY, PROVIDE WIREMOLD 2400 SERIES RACEWAY. MOUNT TO TOPSIDE OF BOTTOM PAN OF SUSPENDED RING TRUSS STRUCTURE FOR A/V POWER. REFER TO ELECTRICAL DETAILS SHEETS FOR RING A/V RACEWAY DIAGRAM. CIRCUIT NUMBERS SHOWN ARE FROM PANELBOARD 'LP-AV' U.O.N.. CIRCUIT AS INDICATED. E229 PROVIDE FINAL CONNECTION TO TYPE 'L5' LIGHT FIXTURES AS REQUIRED. REFER TO RING LIGHTING DETAIL ON ELECTRICAL DETAILS SHEET. CIRCUIT AS INDICATED. E241 PROVIDE TWO GANG JUNCTION BOX IN UPPER MEZZANINE FOR SPEAKER. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR AND ARCHITECTURAL DRAWINGS. NEW FA-BP11- 18 E207 E221 TYPE 'R1' MULTI-OUTLET ASSEMBLY, PROVIDE WIREMOLD 2400 SERIES RACEWAY. MOUNT TO TOPSIDE OF BOTTOM PAN OF SUSPENDED RING TRUSS STRUCTURE FOR LIGHTING POWER. REFER TO ELECTRICAL DETAILS SHEETS FOR RING LIGHTING RACEWAY DIAGRAM. PROVIDE (2)2"FMC CONDUITS WITHIN EACH STRUCTURAL CEILING SUPPORT PIPE TO ACCOMMODATE POWER AND LOW VOLTAGE CONDUCTORS. DERATE POWER CONDUCTORS AS REQUIRED.CIRCUIT NUMBERS SHOWN ARE FROM PANELBOARD 'LP-RING' U.O.N.. CIRCUIT VIA LIGHTING RELAY PANEL. E226 PROVIDE POWER CONNECTION (2-120V CIRCUITS PER BOX) TO 6"X6" JUNCTION BOX MOUNTED ON TOP OF EACH AV RACK. COORDINATE EXACT LOCATION WITH A/V CONTRACTOR. PROVIDE ISOLATED GROUND FOR EACH CIRCUIT. CONNECT TO NEW 'LP-AV' CIRCUITS AS INDICATED. E214 E213 J E210 NEW LP-AV- 34 NEW FA-BL21- 21 E212 J 9 NEW LP-AV- 34 E214 PROVIDE JUNCTION BOX FOR 208V, 3PH PROJECTOR POWER CONNECTION. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR. REFER TO ONE LINE DIAGRAM AND PANEL SCHEDULES FOR CIRCUITING DETAILS. E215 PROVIDE 12" WIDE ALIUMINUM LADDER TRAY MOUNTED ABOVE AV RACKS AT 90"A.F.F. WITH (3)2"C. FROM END OF LADDER RACK TO CONTROL CONSOLE. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR. R2 R1 E212 PROVIDE 12"X12"X4" BACKBOX TO CONTAIN (4) 208V, 20A L6-20R RECEPTACLES AND (4) 120V POWER CONNECTIONS (ALL ISOLATED GROUND CIRCUITS) FOR A/V EQUIPMENT. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR. CIRCUIT TO PANELBOARD 'LP-AV' AS INDICATED. E213 PROVIDE 10"X10"X4" BACKBOX WITH 1-1/2"C. TO A/V MACHINE ROOM FOR A/V EQUIPMENT. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR. J CKTS 12,14,16,18,20 E210 PROVIDE SINGLE GANG JUNCTION BOX IN UPPER MEZZANINE FOR SPEAKER. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR AND ARCHITECTURAL DRAWINGS. E211 PROVIDE (6) SINGLE GANG JUNCTION BOXES BELOW STEPS WITH 1"C. TO A/V MACHINE ROOM FOR A/V EQUIPMENT. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH AV SYSTEM CONTRACTOR. R1 CKTS 1,3,5,7,9 GM DISCLAIMER & TYPICAL NOTES E205 PROVIDE UNISTRUT STRUCTURE TO MOUNT NEW ELECTRICAL EQUIPMENT AT OUTER DOME WALL. E207 RECEPTACLE SHALL BE MOUNTED WITHIN LIGHT COVE FOR TYPE 'L3' LIGHT FIXTURE POWER. COORDINATE EXACT LOCATION IN FIELD. CIRCUIT VIA LIGHTING RELAY PANEL TO CIRCUIT INDICATED. FPB-1 NEW FA-BL21- 15 E207 NOT FOR CON STRU CTIO N E204 PROVIDE ELECTRICAL CONNECTIONS BETWEEN AIR HANDLING UNIT SECTIONS DURING INSTALLATION AS REQUIRED. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL TRADES. 8 3/4"C. TO A/V MACHINE ROOM NEW FA-BL22- 10 COORDINATE FINAL LOCATION OF MECHANICAL EQUIPMENT AND ASSOCIATED DISCONNECT SWITCHES, STARTERS, VFDS, CONTROL POWER AND OTHER POWER REQUIREMENTS WITH DIV 15. SURFACE MOUNTED RACEWAY SHALL NOT BE UTILIZED IN FINISHED AREAS WITHOUT ARCHITECT APPROVAL U.O.N. PROVIDE ALL NECESSARY CABLING FROM SECURITY DEVICES (CAMERAS, DOOR HARDWARE, ETC...) BACK TO NEW SECURITY PANELS. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW ELECTRICAL EQUIPMENT AND DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE SEPARATE ISOLATED GROUND CONDUCTOR FOR EACH CIRCUIT FED FROM ISOLATED GROUND PANEL 'LP-AV'. SITE/BUILDING PLAN & NORTH ARROW M VF D SAF-AHU-1 120V CKTS 37,39,41,43 208V CKTS 45,47 & 49,51 & 53,55 & 57,59 203 D VF VF D E201 22MAY13 BIDS A/V MACHINE ROOM MECH EQUIP ROOM MECH EQUIP ROOM NEW FA-L22- 2,4,6 D VF E244 E. 202 UP RAF-AHU-1 34 6 NEW FA-L22 NEW FA-BL22 NEW FA-BL21- 6 NEW FA-BL22- 2 D. NEW FA-L22- 13,15,17 (TYP.) M (TYP.) UP NEW FA-L21- 1,3,5 A. 5 T-LP-M 30 F NEW FA-BL21- 9 DN J F VFD E205 PROVIDE (3) ANALOG PHONE LINES PER VOICE JUNCTION BOX NEW LP-AV- 10 PROJECTOR NEW FA-BL21- 39,41,43 NEW FA-L21 NEW FA-BL21 DEPT. MGR/SUPR APPROVAL SHEET NOTES GROUND BAR FC-1 PROJECT ARCH/ ENGR APPROVAL ISSUED FOR 3 37 GROUND BAR DATE MEZZANINE FLOOR POWER AUXILIARY SYSTEMS PLAN WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 1/8" = 1'-0" 25 24 23 22 21 20 19 18 17 DATE 22MAY13 FILE PLOT DATE STAMP EP1−202 5/21/2013 12:17:01 PM WFG JOB NO. − SHEET NO. SHEET NOTES A. 1 39 36 2 B. 40 38 3 C. D. E. 37 4 DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS COORDINATE FINAL LOCATION OF MECHANICAL EQUIPMENT AND ASSOCIATED DISCONNECT SWITCHES, STARTERS, VFDS, CONTROL POWER AND OTHER POWER REQUIREMENTS WITH DIV 15. SURFACE MOUNTED RACEWAY SHALL NOT BE UTILIZED IN FINISHED AREAS WITHOUT ARCHITECT APPROVAL U.O.N. PROVIDE ALL NECESSARY CABLING FROM SECURITY DEVICES (CAMERAS, DOOR HARDWARE, ETC...) BACK TO NEW SECURITY PANELS. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW ELECTRICAL EQUIPMENT AND DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE SEPARATE ISOLATED GROUND CONDUCTOR FOR EACH CIRCUIT FED FROM ISOLATED GROUND PANEL 'LP-AV'. 5 110 KEYED NOTES 110 35 E239 DISCONNECT POWER FROM EXISTING WENCH UTILIZED TO RAISE AND LOWER ITEMS FROM THE DOME CEILING. WENCH SHALL BE REFURBISHED OR REPLACED BY MECHANICAL TRADES. RECONNECT TO EXISTING CIRCUIT UPON REINSTALLTION. REPAIR OR REPLACE CONTROLS AS NECESSARY. 6 SITE/BUILDING PLAN & NORTH ARROW 34 NOT FOR CON STRU CTIO N 7 110 GM DISCLAIMER & TYPICAL NOTES 110 33 8 32 9 31 110 10 T-LP-RING LP-RING T E239 (E)EF-4 NO. 30 11 110 PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM 12 29 CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com 13 28 Worldwide Facilities Group 110 General Motors Corporation 110 Warren Technical Center Campus Site ID: 1563 14 27 Structure ID: 4235 Level: 15 110 UPPER MEZZANINE FLOOR POWER AUXILIARY SYSTEMS PLAN 26 WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author 16 SCALE 1/8" = 1'-0" 25 24 23 22 21 20 19 18 17 DATE 22MAY13 FILE PLOT DATE STAMP EP1−203 5/21/2013 12:17:09 PM WFG JOB NO. − SHEET NO. ROOM LEGEND 1 39 36 2 40 38 37 121 EMERGENCY LIGHTING (1 ROW) NEW LP-M-1E-8 101 102 103 104 105 106 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 124 125 126 127A 127B 127C 127D 3 4 EMERGENCY LIGHTING (1 ROW) NEW LP-M-1E-8 E331 (TYP.) WEST FIXTURES TO NEW LP-BL22-18 EAST FIXTURES TO NEW LP-BL22-20 5 E313 E310 L12 (TYP.) L14 UP E310 DT E311 35 L13 (TYP.) F5 (TYP.) 126 125 (TYP.) L12 L6B L11 (TYP.) E309 L13 (TYP.) 34 E310 L12 (TYP.) DT NEW FA-BL13- 11 L16 L16 102 EM DT L11 A. (TYP.) L13 (TYP.) 104 E311 120 105 E311 E323 DN EL TD 7 DN UP B. C. UP D. 119 106 E. 3 33 F. OS 127A CONNECT TYPE 'L17' LIGHT FIXTURE TO GENERAL USE 120V, RECEPTACLE CIRCUIT SERVING EXISTING RECEPTACLES MOUNTED BELOW STEPS (TYP.) 127C NEW FA-BL13- 11 F6 EM/NL L22 J J (TYP.) NEW FA-BL21-37 E319 101 L6A E317 NEW LP-M-1E- 4 (TYP.) NEW FA-BL21-38 K 31 3 D D NEW FA-BL12- 7 E319 NEW FA-BL21- 38 (TYP.) NEW FA-BL21- 37 DN E309 E317 L6A NEW LP-M-1E- 2 L7 (TYP.) 10 L7 NEW FA-BL21-37 116 EM-NL (TYP.) 4 EM-NL 4 109 117 L6A (TYP.) NEW FA-BL21-38 EM-NL E308 30 L7 L9 L7 EM-NL L22 (TYP.) F2 E326 (TYP.) DT NEW FA-BL21-37 NEW FA-BL13- 12 LRP (TYP.) L6C E312 (TYP.) 111 L22 EM-NL 11 K (TYP.) E312 DN E323 E328 110 12 ELT D DT 115 114 NEW FA-BP11- 7 28 112 DT DT DN DN E301 13 DT E327 E327 DT E301 14 E319 NEW FA-BP11- 22 J 113 NEW LP-M-1E- 7 J 27 E317 15 E308 L8 L10 (TYP.) GM DISCLAIMER & TYPICAL NOTES E311 FIXTURE TYPE L13 TO BE SURFACE MOUNTED WITHIN ARCHITECTURAL COVE. SEE A9 SERIES DRAWINGS FOR DETAIL. CONTINUE FINISHED WALL TREATMENT INTO CEILING COVE CAVITY. TYPICAL FOR ALL L13 FIXTURES. E312 FIXTURE TYPE L22 TO BE SURFACE MOUNTED TO CONCRETE FOOTER. SEE A9 SERIES DRAWINGS FOR DETAIL. TYPICAL FOR ALL L22 FIXTURES. E313 FIXTURE TYPE L14 TO BE SURFACE MOUNTED WITHIN ARCHITECTURAL CAVITY TO UNIFORMLY BACKLIGHT DIFFUSE MATERIAL. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL F14 FIXTURES. CONCEAL DATA ENABLER IN ACCESIBLE LOCATION. NO. E306 DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E E317 JUNCTION BOX FOR TYPE L7/L8 LIGHT FIXTURES, MOUNT JUNNCTION BOX HIDDEN IN COVE. REFER TO COVE EMERGENCY LIGHTING DETAIL ON ELECTRICAL DETAILS SHEET. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. UTILIZE CIRCUIT INDICATED. FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Worldwide Facilities Group E323 PROVIDE ONE EMERGENCY LOAD TRANSFER DEVICE (ELTD) FOR EACH SWITCHED CIRCUIT FOR EXISTING STAIR LIGHTING. CONNECT EMERGENCY SIDE OF ELTD TO SPARE 20A CIRCUIT BREAKER IN PANEL BOARD 'LP-M-1E'. CONNECT NORMAL SIDE TO EXISTING NORMAL CIRCUIT. VERIFY QUANTITY AND LOCATION IN FIELD. E325 CONNECT EMERGENCY/NIGHT LIGHT TO PANELBOARD LP-M-1E CIRCUIT AS INDICATED. E326 PROVIDE KEY SWITCH FOR CONTROL OF LOBBY AND CANOPY LIGHT FIXTURES. CIRCUIT AS INDICATED. E327 DISCONNECT EXISTING LIGHT FIXTURE FROM EXISTING NORML CIRCUIT. CONNECT EXISTING FIXTURE LIFE SAFETY LIGHTING CIRCUIT SERVING ADJACENT AREA. FIXTURE SHALL FUNCTION AS NIGHTLIGHT. PROJECT ARCH/ ENGR APPROVAL DATE E319 JUNCTION BOX FOR TYPE L9/L10 LIGHT FIXTURE, MOUNT JUNCTION BOX HIDDEN IN COVE. COVE LIGHTING DETAIL NO.3 ON ELECTRICAL DETAILS SHEET. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. UTILIZE CIRCUITS INDICATED. 124 E301 NOT FOR CON STRU CTIO N E308 FIXTURE TYPES L7, L8, L9 AND L10 TO BE SURFACE MOUNTED TO ANGLED BRACKET WITHIN COVE SO THAT NO DIRECT VIEW OF FIXTURE IS POSSIBLE. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. PROVIDE 2 BRACKETS PER FIXTURE. MOUNT ALL FIXTURES IN CROSS SECTION TO SAME ANGLED MOUNTNG BRACKET. SPACE FIXTURES EVENLY WITHIN FIXTURE RUN SO THERE ARE NO UNLIT SECTIONS. TYPICAL FOR ALL L7, L8, L9 AND L10 FIXTURES WITHIN CENTER DOME COVE, ENTRY COVE, AND STAGE COVE. E310 FIXTURE TYPE L12 INCLUDES VANITY MIRROR WITH INTEGRAL LIGHTING COMPONENT. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL L12 FIXTURES. L7 NEW FA-BL21-37 L6A E309 NEW FA-BL21-38 L6A (TYP.) 29 E325 (TYP.) E308 L7 L9 (TYP.) (TYP.) NEW FA-BL21-38 SITE/BUILDING PLAN & NORTH ARROW E309 FIXTURE TYPE L6A AND L6B TO BE TRACK MOUNTED. SEE A9 SERIES DRAWINGS FOR TRACK MOUNTING CONDITION. SEE PLANS FOR TRACK LENGTH. TYPICAL FOR ALL L6A AND L6B FIXTURES. 108 L6A (TYP.) NEW FA-BL21-37 K (TYP.) L11B (TYP.) EM-NL L11B (TYP.) L11A (TYP.) L11A E325 CONNECT CEILING MOUNTED OCCUPANCY SENSORS TO POWER PACKS WITH LOW VOLTAGE WIRING. PROVIDE NUMBER OF POWER PACKS RECOMMENDED BY MANUFACTURER. COORDINATE COMPATABILITY WITH LIGHTING CONTACTORS OR INDICATED SWITCHES. REFER TO MANUFACTURER WIRING DIAGRAMS. REFER TO ARCH. REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES AND OTHER CEILING MOUNTED DEVICES. PROVIDE SEPARATE NEUTRALS FOR DIMMING CIRCUITS. POWER TO DMX CONTROLLED LIGHT FIXTURES SHALL BE VIA RELAY PANELS AS INDICATED ON PANELBOARD PANEL SCHEDULES. FOR LIGHT FIXTURES SPECIFIED WITH PLUG AND CORD, REFER TO POWER PLANS FOR RECEPTACLE AND CIRCUITING INFORMATION AND LOCATION. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE NEW LED SCREW-IN TYPE LAMPS FOR EXISITNG TO REMAIN INCANDESCENT LIGHT FIXTURES. E306 FIXTURE TYPE L3 TO BE SURFACE MOUNTED AND CENTERED WITHIN ARCHITECTURAL CAVITY SO THAT FIXTURE HAS UNIMPEDED FULL RANGE OF MOTION. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL L3 FIXTURES. E312 NEW FA-BL13- 11 J J L22 EM-NL 4 NEW FA-BL13- 11 9 F6A (TYP.) K NEW FA-BL21-38 EM-NL 4 127B 118 E326 DISPLAY AREA BOARDROOM JC WOMEN'S WASH ROOM WOMEN'S TOILET MECH EQUIP ROOM LOBBY ENTRY STAIR LOBBY CHAIR STORAGE RM CORRIDOR PLATFORM SERVICE ENTRY MULTI-PURPOSE ROOM LOBBY ENTRY COAT ROOM MECH EQUIP ROOM MEN'S TOILET MEN'S WASH ROOM JC ELEVATOR STAIR STAIR COPY ROOM/CIRCULATION GREEN ROOM CLOSET SECURITY CLOSET E301 PROVIDE NEW OCCUPANCY SENSOR FOR AUTOMATIC CONTROL OF EXISTING LIGHTING WITHIN THIS SPACE. EXISTING MANUAL LIGHTING CONTROLS SHALL REMAIN. CONNECT EMERGENCY/NIGHT LIGHT LIGHT TO 120V LIFE SAFETY CIRCUIT FEEDING ADJACENT ENTRY. D F3 (TYP.) NEW FA-BL12- 9 22MAY13 BIDS KEYED NOTES OS (TYP.) 32 G. F4 F4 DT E312 8 NEW FA-BL13- 11 L17 (TYP. OF 6) DEPT. MGR/SUPR APPROVAL SHEET NOTES E311 NEW LP-M-1E-8 NEW LP-M-1E-8 PROJECT ARCH/ ENGR APPROVAL ISSUED FOR 6 L13 NEW FA-BL12- 7 EM E310 E329 (TYP.) ELTD DT F5 L12 (TYP.) UP DATE General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: E328 PROVIDE ETC SMARTSWITCH RELAY PANELS TO ACCOMMODATE DMX LIGHTING CIRCUITS FED FROM 'FA-BP11'. REFER TO PANEL SCHEDULES FOR QUANTITY REQUIRED. PROVIDE 25% SPARE RELAY CAPACITY. COORDINATE MOUNTING LOCATION IN FIELD. CONNECT TO SPARE 20A, 1P CIRUIT BREAKER FROM 'FA-BP11' FOR RELAY PANEL CONTROL POWER. FIRST FLOOR LIGHTING PLAN E329 FIXTURE TYPE F5 TO BE RECESSED IN WALL TO BACKLIGHT TRANSLUCENT PANE IN MIRROR. SEE ARCHITECTURAL DRAWING AE4-712 DRAWINGS FOR DETAIL AND EXACT MOUNTING LOCATION. TYPICAL FOR ALL F5 FIXTURES. L3 (TYP.) 26 16 E331 BOARDROOM LIGHT FIXTURES SHALL BE CONTROLLED VIA LOCAL LIGHTING CONTROLS IN CONJUNCTION WITH DMX CONTROL PROVIDED BY OTHERS. COORDINATE INTERCONNECTING WIRING REQUIREMENTS WITH AV CONTRACTOR. WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 1/8" = 1'-0" DATE 25 24 23 22 21 20 19 18 17 22MAY13 FILE PLOT DATE STAMP EL1−301 5/21/2013 12:16:17 PM WFG JOB NO. − SHEET NO. ROOM LEGEND 1 39 36 201 202 203 2 40 38 4 B. C. D. 5 E. 201 ELTD ELTD 35 F. DN G. E323 E324 E324 E322 E318 34 CONNECT CEILING MOUNTED OCCUPANCY SENSORS TO POWER PACKS WITH LOW VOLTAGE WIRING. PROVIDE NUMBER OF POWER PACKS RECOMMENDED BY MANUFACTURER. COORDINATE COMPATABILITY WITH LIGHTING CONTACTORS OR INDICATED SWITCHES. REFER TO MANUFACTURER WIRING DIAGRAMS. REFER TO ARCH. REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES AND OTHER CEILING MOUNTED DEVICES. PROVIDE SEPARATE NEUTRALS FOR DIMMING CIRCUITS. POWER TO DMX CONTROLLED LIGHT FIXTURES SHALL BE VIA RELAY PANELS AS INDICATED ON PANELBOARD PANEL SCHEDULES. FOR LIGHT FIXTURES SPECIFIED WITH PLUG AND CORD, REFER TO POWER PLANS FOR RECEPTACLE AND CIRCUITING INFORMATION AND LOCATION. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE NEW LED SCREW-IN TYPE LAMPS FOR EXISITNG TO REMAIN INCANDESCENT LIGHT FIXTURES. KEYED NOTES UP NEW FA-BL21-18 & 20 SITE/BUILDING PLAN & NORTH ARROW E307 L9 L7 (TYP.) E302 J 202 203 7 L7 DN DN J L3 (TYP.) E308 L7 L9 L10 (TYP.) L8 E306 J FIXTURE TYPES L1, L2 AND L6 TO BE C-CLAMP MOUNTED TO THEATRICAL PIPE AND SECURED WITH SAFETY CABLE. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL L1, L2 AND L6 FIXTURES MOUNTED ON STAGE THEATRICAL PIPE. E304 FIXTURE TYPE L1 TO BE C-CLAMP MOUNTED TO THEATRICAL PIPE ABOVE CATWALK AND SECURED WITH SAFETY CABLE. TYPICAL FOR ALL L1 FIXTURES MOUNTED ABOVE CATWALK. E305 FIXTURE TYPE L5 TO BE SURFACE MOUNTED TO CENTER DOME RING TRUSS TO LIGHT DOME CEILING. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL L5 FIXTURES. E306 FIXTURE TYPE L3 TO BE SURFACE MOUNTED AND CENTERED WITHIN ARCHITECTURAL CAVITY SO THAT FIXTURE HAS UNIMPEDED FULL RANGE OF MOTION. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL L3 FIXTURES. E307 FIXTURE TYPES L7 AND L9 TO BE SURFACE MOUNTED WITHIN ARCHITECTURAL COVE SO THAT NO DIRECT VIEW OF FIXTURE IS POSSIBLE. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. SHIM SO TOP OF FIXTURE IS FLUSH WITH TOP OF COVE LIP. CONNECT FIXTURES END-TO-END WITHOUT JUMPER CABLES. EVENLY SPACE UNLIT PORTIONS OF COVE AT BOTH ENDS OF FIXTURE RUN. TYPICAL FOR ALL L7 AND L9 FIXTURES LOCATED WITHIN PERIMETER DOME COVE. E308 FIXTURE TYPES L7, L8, L9 AND L10 TO BE SURFACE MOUNTED TO ANGLED BRACKET WITHIN COVE SO THAT NO DIRECT VIEW OF FIXTURE IS POSSIBLE. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. PROVIDE 2 BRACKETS PER FIXTURE. MOUNT ALL FIXTURES IN CROSS SECTION TO SAME ANGLED MOUNTNG BRACKET. SPACE FIXTURES EVENLY WITHIN FIXTURE RUN SO THERE ARE NO UNLIT SECTIONS. TYPICAL FOR ALL L7, L8, L9 AND L10 FIXTURES WITHIN CENTER DOME COVE, ENTRY COVE, AND STAGE COVE. E309 FIXTURE TYPE L6A AND L6B TO BE TRACK MOUNTED. SEE A9 SERIES DRAWINGS FOR TRACK MOUNTING CONDITION. SEE PLANS FOR TRACK LENGTH. TYPICAL FOR ALL L6A AND L6B FIXTURES. E316 NEW FA-BL21-26 & 28 E317 33 8 L7 E317 L7 J J NEW LP-M-1E- 5 E316 NEW FA-BL21-25 & 27 NEW FA-BL21-22 & 24 E318 J 9 J E318 (4 ROWS TYP.) L5 E305 NEW FA-BL21-14 & 16 E302 NEW FA-BL21-16 L1 L1 L1 L1 L2 L1 L1 L6 (TYP.) L1 31 L1 L2 L1 L2 E317 L1 (TYP.) L7 E309 NEW LP-M-1E- 3 L1 L2 L2 L1 30 J E302 L1 E309 J (TYP.) L6A L1 L1 L7 NEW FA-BL21-30 & 32 L1 L1 10 E316 L1 E302 L1 L6A NEW FA-BL21-24 L1 L1 L1 L1 L2 L2 L1 L2 L1 L1 L1 L1 L1 11 L1 L1 E316 L1 UP E317 29 12 E317 NEW LP-M-1E- 1 J E318 J E316 NEW FA-BL21-29 & 31 NEW LP-M-1E- 1 L7 L7 E317 E320 E316 J 28 NEW FA-BL21-33 & 35 NEW FA-BL21-34 & 36 J 13 E316 E317 J NEW LP-M-1E- 3 J E306 L3 E322 (TYP.) L7 L7 L1 L1 (TYP.) L6 27 L1 E304 (TYP.) L6 L1 L1 L2 L1 L2 L1 L2 L2 L2 L6 E323 E303 L2 L6 (TYP.) 14 (TYP.) L2 L2 (TYP.) L6 (TYP.) (TYP.) 15 FIXTURE TYPES L1, L2 AND L6 TO BE C-CLAMP MOUNTED TO THEATRICAL PIPE AND SECURED WITH SAFETY CABLE. SEE A9 SERIES DRAWINGS FOR MOUNTING DETAIL. TYPICAL FOR ALL L1, L2 AND L6 FIXTURES MOUNTED ON CENTER DOME RING TRUSS. E303 L7 NEW LP-M-1E- 5 32 22MAY13 BIDS 6 LR P E322 UP DEPT. MGR/SUPR APPROVAL SHEET NOTES 37 LRP PROJECT ARCH/ ENGR APPROVAL ISSUED FOR A/V MACHINE ROOM MECH EQUIP ROOM MECH EQUIP ROOM 3 A. DN E323 DATE E324 JUNCTION BOX FOR TYPE L8, L9, AND L10 LIGHT FIXTURE, MOUNT JUNCTION BOX HIDDEN IN COVE. REFER TO COVE LIGHTING DETAIL NO.1 ON ELECTRICAL DETAILS SHEET. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. UTILIZE CIRCUITS INDICATED. JUNCTION BOX FOR TYPE L7/L8 LIGHT FIXTURES, MOUNT JUNNCTION BOX HIDDEN IN COVE. REFER TO COVE EMERGENCY LIGHTING DETAIL ON ELECTRICAL DETAILS SHEET. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. UTILIZE CIRCUIT INDICATED. NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES NO. DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E JUNCTION BOX FOR TYPE L7, AND L9 LIGHT FIXTURE, MOUNT JUNCTION BOX HIDDEN IN COVE. COVE LIGHTING DETAIL NO.2 ON ELECTRICAL DETAILS SHEET. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. UTILIZE CIRCUITS INDICATED. FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com PROVIDE ETC SMARTSWITCH RELAY PANELS TO ACCOMMODATE LIGHTING CIRCUITS ON THE SUSPENDED RING. REFER TO PANEL SCHEDULE FOR 'LP-RING' FOR QUANTITY REQUIRED. PROVIDE 25% SPARE RELAY CAPACITY. COORDINATE MOUNTING LOCATION IN UPPER MEZZANINE IN FIELD. CONNECT TO SPARE 20A, 1P CIRUIT BREAKER FROM 'LP-RING' FOR RELAY PANEL CONTROL POWER. PROVIDE ETC SMARTSWITCH RELAY PANELS TO ACCOMMODATE DMX LIGHTING CIRCUITS FED FROM 'FA-BL21/FA-BL22'. REFER TO PANEL SCHEDULES FOR QUANTITY REQUIRED. PROVIDE 25% SPARE RELAY CAPACITY. COORDINATE MOUNTING LOCATION IN FIELD. CONNECT TO SPARE 20A, 1P CIRUIT BREAKER FROM 'FA-BL21/FA-BL22' FOR RELAY PANEL CONTROL POWER. COORDINATE CONTROL WIRING REQUIREMENTS WITH DMX LIGHTING CONTROLS PROVIDER. PROJECT ARCH/ ENGR APPROVAL DATE Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 PROVIDE ONE EMERGENCY LOAD TRANSFER DEVICE (ELTD) FOR EACH SWITCHED CIRCUIT FOR EXISTING STAIR LIGHTING. CONNECT EMERGENCY SIDE OF ELTD TO SPARE 20A CIRCUIT BREAKER IN PANEL BOARD 'LP-M-1E'. CONNECT NORMAL SIDE TO EXISTING NORMAL CIRCUIT. VERIFY QUANTITY AND LOCATION IN FIELD. Level: DISCONNECT EXISTING 4' CHAIN HUNG INDUSTRIAL LIGHT FIXTURE INSIDE DOOR OF MECHANICAL/ELECTRICAL SPACE FROM EXISTING NORML CIRCUIT. CONNECT EXISTING FIXTURE TO SPARE 20A CIRCUIT BREAKER IN PANEL BOARD 'LP-M-1E'. FIXTUE SHALL FUNCTION AS NIGHTLIGHT. EXTEND EXISTING NORMAL CIRCUIT AS REQUIRED TO COMPLETE THE CIRCUIT. MEZZANINE FLOOR LIGHTING PLAN 26 WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author 16 SCALE 25 1/8" = 1'-0" 24 23 22 21 20 19 18 17 DATE 22MAY13 FILE PLOT DATE STAMP EL1−302 5/21/2013 12:16:27 PM − SHEET NO. SHEET NOTES 1 39 36 A. 2 40 38 3 B. C. D. 37 4 E. F. 5 G. DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS CONNECT CEILING MOUNTED OCCUPANCY SENSORS TO POWER PACKS WITH LOW VOLTAGE WIRING. PROVIDE NUMBER OF POWER PACKS RECOMMENDED BY MANUFACTURER. COORDINATE COMPATABILITY WITH LIGHTING CONTACTORS OR INDICATED SWITCHES. REFER TO MANUFACTURER WIRING DIAGRAMS. REFER TO ARCH. REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURES AND OTHER CEILING MOUNTED DEVICES. PROVIDE SEPARATE NEUTRALS FOR DIMMING CIRCUITS. POWER TO DMX CONTROLLED LIGHT FIXTURES SHALL BE VIA RELAY PANELS AS INDICATED ON PANELBOARD PANEL SCHEDULES. FOR LIGHT FIXTURES SPECIFIED WITH PLUG AND CORD, REFER TO POWER PLANS FOR RECEPTACLE AND CIRCUITING INFORMATION AND LOCATION. COORDINATE MOUNTING HEIGHT AND LOCATION OF NEW DEVICES WITH ARCHITECTURAL PLANS PRIOR TO INSTALLTION. PROVIDE NEW LED SCREW-IN TYPE LAMPS FOR EXISITNG TO REMAIN INCANDESCENT LIGHT FIXTURES. KEYED NOTES 35 E320 PROVIDE ETC SMARTSWITCH RELAY PANELS TO ACCOMMODATE LIGHTING CIRCUITS ON THE SUSPENDED RING. REFER TO PANEL SCHEDULE FOR 'LP-RING' FOR QUANTITY REQUIRED. PROVIDE 25% SPARE RELAY CAPACITY. COORDINATE MOUNTING LOCATION IN UPPER MEZZANINE IN FIELD. CONNECT TO SPARE 20A, 1P CIRUIT BREAKER FROM 'LP-RING' FOR RELAY PANEL CONTROL POWER. 6 34 E321 PROVIDE ONE EMERGENCY LOAD TRANSFER DEVICE (ELTD) FOR EACH SWITCHED CIRCUIT FOR EXISTING UPPER MEZZANINE LIGHTING. CONNECT EMERGENCY SIDE OF ELTD TO SPARE 20A CIRCUIT BREAKER IN PANEL BOARD 'LP-M-1E'. CONNECT NORMAL SIDE TO EXISTING NORMAL CIRCUIT. VERIFY QUANTITY AND LOCATION IN FIELD. 7 SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES 33 8 32 9 31 10 E321 ELTD ELTD ELTD ELTD LRP LRP WFG JOB NO. (TYP.) E320 (TYP.) NO. PROJECT ARCH/ ENGR APPROVAL DATE 11 30 DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM 12 29 CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com 13 28 Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 14 27 Structure ID: 4235 Level: 15 UPPER MEZZANINE FLOOR LIGHTING PLAN 26 WFG PE/PM WFG JOB NO N. WEINGARTZ 16 DRAWN BY 1200912 SHEET NUMBER Author SCALE 25 24 23 22 21 20 19 18 17 1/8" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EL1−303 5/21/2013 12:16:32 PM WFG JOB NO. SHEET NO. − 30" MAXIMUM LENGTH L14 L14 DATE DATA ENABLER (TYP.) EMERGENCY BYPASS CONTROLLER (TYP.) LV DATA TO DMX CONTROL (BY OTHERS) EBC CKT-1 CKT-2 CKT-3 CKT-4 CKT-5 TO DMX CONTROL (BY OTHERS) NORMAL NOTES: L1 L6 L1 L6 L1 L6 1. PROVIDE QUANTITY OF DATA ENABLERS AS REQUIRED FOR CONTINUOUS FIXTURE RUN. CONCEAL DATA ENABLER IN LIGHT COVE AS NOT TO INTERFERE WITH LIGHT DISTRIBUTION. 2. REFER TO ARCHITECTURAL PLANS FOR MOUNTING. 3. REFER TO LIGHTING PLANS AND PANEL SCHEDULES FOR CIRCUITING INFORMATION. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. L2 EMERGENCY CONTROL NOTES: 1. PROVIDE DEVICE QUANTITIES AS NEEDED. COORDINATE WITH LIGHTING CONTROL SYSTEM PROVIDER FOR INSTALLATION LOCATIONS AND QUANTITIES. 2. EMERGENCY LIGHTING CONTROL OPERATION: A. UNDER" NORMAL" POWER CONDITIONS, ALL LIGHT FIXTURES SHALL BE CONTROLLED VIA THEIR RESPECTIVE DMX CHANNELS. B. UPON LOSS OF "NORMAL" POWER AND SUBSEQUENTS CONNECTION TO "EMERGENCY" POWER, SELECTED FIXTURES SHALL ILLUMINATE TO FULL OUTPUT REGARDLESS OF ON/OFF/DIMMING STATE PRIOR TO LOSS OF "NORMAL" POWER. C. UPON RETURN TO "NORMAL" POWER, FULL CONTROL CAPABILITY SHALL AUTOMATICALLY RETURN TO THE LIGHTING CONTROL SYSTEM. 3. COORDINATE EXACT REQUIREMENTS FOR POWER WIRING, CONTROL WIRING, AND INTERFACE DEVICES WITH LIGHTING CONTROL SUPPLIER. LIGHT FIXTURE TYPE (TYP) NOTES: 1. PROVIDE MISC. FITTINGS/COMPONENTS AS REQUIRED FOR A COMPLETE AND FUNTIONAL RACEWAY. 2. LIGHT FIXTURE PLUG DESIGNATION LOCATIONS SHOWN FOR FIXTURE TYPE COUNTS PER CIRCUIT. ACTUAL LOCATIONS MAY VARY DUE TO LIGHT FIXTURE LAYOUT. 3. MOUNT RACEWAY HORIZONTALLY ON TOP OF SHEET METAL PANEL MOUNTED WITHIN TRUSS STRUCTURE. REFER TO POWER AND ARCHITECTURAL PLANS FOR MOUNTING LOCATION. 4. PROVIDE WIRE MANAGEMENT SYSTEM SIMILAR TO PANDUIT G2X2WH6 SERIES IN TRUSS STRUCTURE SECTIONS (WHERE NO RACEWAY IS REQUIRED) FOR ROUTING OF LIGHT FIXTURE CORDS AND LOW VOLTAGE WIRING. 1 R1 - RING LIGHTING RACEWAY DIAGRAM 8 SCALE: NOT TO SCALE BOARDROOM DMX LIGHTING DETAIL SITE/BUILDING PLAN & NORTH ARROW SCALE: NOT TO SCALE COUNTER CLOCKWISE AROUND COVE (WHERE APPLICABLE) CLOCKWISE AROUND COVE (WHERE APPLICABLE) 120V EMERGENCY CIRCUIT VIA DMX RELAY PANEL 30" MAXIMUM L7 OR L8 L7 OR L8 L7 OR L8 L7 OR L8 DE J DAISY CHAIN UTILIZING MANUFACTURER'S JUMPER CABLES LV DATA TO DMX CONTROL (BY OTHERS) EBC NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES DATA ENABLER (TYP.) EMERGENCY BYPASS CONTROLLER (TYP.) 24-DWND-FW L7 OR L8 L7 OR L8 DE DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) WIREMOLD 2400 SERIES FMC CONDUIT 120V CIRCUIT VIA DMX RELAY PANEL BY OTHERS (TYP.) 480V OR 208V, 3P, 20A NORMAL POWER SOURCE SENSING FEED. DETERMINE SOURCE UPON VERIFICATION OF NORMAL FEED SOURCE TO EXISTING ATS. SPARE L6 J DATA ENABLER (TYP.) EMERGENCY DUPLEX RECEPTACLE UNDER FACE (TYP) L14 DE DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) EMERGENCY BYPASS DETECTOR (TYP.) EBD L14 BY OTHERS (TYP.) 120V, 20A EMERGENCY POWER FEED. DETERMINE SOURCE UPON VERIFICATION OF EMERGENCY FEED SOURCE TO EXISTING ATS. 2410FC-FW DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS L14 24-DWND-FW PROJECT ARCH/ ENGR APPROVAL ISSUED FOR J DE DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) WIREMOLD 2400 SERIES FMC CONDUIT L14 120V EMERGENCY CIRCUIT VIA DMX RELAY PANEL BY OTHERS (TYP.) LV DATA EMERGENCY BYPASS DETECTOR (TYP.) EBD EMERGENCY BYPASS CONTROLLER (TYP.) EBD TO DMX CONTROL (BY OTHERS) EBC 120V, 20A EMERGENCY POWER FEED. DETERMINE SOURCE UPON VERIFICATION OF EMERGENCY FEED SOURCE TO EXISTING ATS. 120V, 20A EMERGENCY POWER FEED. DETERMINE SOURCE UPON VERIFICATION OF EMERGENCY FEED SOURCE TO EXISTING ATS. 2410FC-FW CKT-1 CKT-2 480V OR 208V, 3P, 20A NORMAL POWER SOURCE SENSING FEED. DETERMINE SOURCE UPON VERIFICATION OF NORMAL FEED SOURCE TO EXISTING ATS. CKT-3 NOTES: ER 1. PROVIDE QUANTITY OF DATA ENABLERS AS REQUIRED FOR CONTINUOUS FIXTURE RUN. CONCEAL DATA ENABLER IN LIGHT COVE AS NOT TO INTERFERE WITH LIGHT DISTRIBUTION. 2. TOP OF COVE MOUNTED LIGHT FIXTURES SHALL BE FLUSH WITH TOP OF COVE LIP. PROVIDE MOUNTING HARWARE AS REQUIRED. 3. INDIVIDUAL FIXTURE RUN LENGTH SHALL NOT EXCEED 40' FOR CIRCUITING PURPOSES. REFER TO LIGHTING PLANS FOR CIRCUITING INFORMATION. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. AK TO R SP E PR O SP E JE C AK DUPLEX ISOLATED GROUND RECEPTACLE UNDER FACE (TYP) ER NOTES: 1. PROVIDE MISC. FITTINGS/COMPONENTS AS REQUIRED FOR A COMPLETE AND FUNTIONAL RACEWAY. 2. A/V EQUIPMENT PLUG DESIGNATION LOCATIONS SHOWN FOR EQUIPMENT TYPE COUNTS PER CIRCUIT. ACTUAL LOCATIONS MAY VARY DUE TO LIGHT FIXTURE AND A/V EQUIPMENT LAYOUT. 3. MOUNT RACEWAY HORIZONTALLY ON TOP OF SHEET METAL PANEL MOUNTED WITHIN TRUSS STRUCTURE BELOW PROJECTOR. REFER TO POWER AND ARCHITECTURAL PLANS FOR MOUNTING LOCATION. 4. PROVIDE WIRE MANAGEMENT SYSTEM SIMILAR TO PANDUIT G2X2WH6 SERIES IN TRUSS STRUCTURE SECTIONS (WHERE NO RACEWAY IS REQUIRED) FOR ROUTING OF A/V CORDS AND LOW VOLTAGE WIRING. 2 R2 - RING A/V RACEWAY DIAGRAM EMERGENCY CONTROL NOTES: 1. PROVIDE DEVICE QUANTITIES AS NEEDED. COORDINATE WITH LIGHTING CONTROL SYSTEM PROVIDER FOR INSTALLATION LOCATIONS AND QUANTITIES. 2. EMERGENCY LIGHTING CONTROL OPERATION: A. UNDER" NORMAL" POWER CONDITIONS, ALL LIGHT FIXTURES SHALL BE CONTROLLED VIA THEIR RESPECTIVE DMX CHANNELS. B. UPON LOSS OF "NORMAL" POWER AND SUBSEQUENTS CONNECTION TO "EMERGENCY" POWER, SELECTED FIXTURES SHALL ILLUMINATE TO FULL OUTPUT REGARDLESS OF ON/OFF/DIMMING STATE PRIOR TO LOSS OF "NORMAL" POWER. C. UPON RETURN TO "NORMAL" POWER, FULL CONTROL CAPABILITY SHALL AUTOMATICALLY RETURN TO THE LIGHTING CONTROL SYSTEM. 3. COORDINATE EXACT REQUIREMENTS FOR POWER WIRING, CONTROL WIRING, AND INTERFACE DEVICES WITH LIGHTING CONTROL SUPPLIER. 5 SCALE: NOT TO SCALE COVE EMERGENCY LIGHTING DETAIL SCALE: NOT TO SCALE NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 (2) 120V CIRCUITS VIA DMX RELAY PANEL L7 L7 L7 DE L9 L9 SUPPLIER DRAWN BY L7 L7 DE DATA L9 L7 DATA SUPPLIER CHECKED BY L9 L9 120V CIRCUIT VIA DMX RELAY PANEL L9 SUPPLIER PE/PM J DE DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) DATA DE L9 OR L10 L9 OR L10 L9 OR L10 L9 OR L10 L9 OR L10 L9 OR L10 DATA DAISY CHAIN UTILIZING MANUFACTURER'S JUMPER CABLES BY OTHERS (TYP.) DATA ENABLER (TYP.) J DE DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) DATA CONSULTANT A/E DE DATA DAISY CHAIN UTILIZING MANUFACTURER'S JUMPER CABLES BY OTHERS (TYP.) DATA ENABLER (TYP.) (1)CIRCUIT COUNTER CLOCKWISE AROUND COVE (1)CIRCUIT CLOCKWISE AROUND COVE FIRM INFO & LOGO COUNTER CLOCKWISE AROUND COVE (WHERE APPLICABLE) SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com CIRCUIT CLOCKWISE AROUND COVE AS REQUIRED (WHERE APPLICABLE) NOTES: NOTES: 1. PROVIDE QUANTITY OF DATA ENABLERS AS REQUIRED FOR CONTINUOUS FIXTURE RUN. CONCEAL DATA ENABLER IN LIGHT COVE AS NOT TO INTERFERE WITH LIGHT DISTRIBUTION. 2. TOP OF COVE MOUNTED LIGHT FIXTURES SHALL BE FLUSH WITH TOP OF COVE LIP. PROVIDE MOUNTING HARWARE AS REQUIRED. 3. INDIVIDUAL FIXTURE RUN LENGTH SHALL NOT EXCEED 44' FOR CIRCUITING PURPOSES. REFER TO LIGHTING PLANS FOR CIRCUITING INFORMATION. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. 1. PROVIDE QUANTITY OF DATA ENABLERS AS REQUIRED FOR CONTINUOUS FIXTURE RUN. CONCEAL DATA ENABLER IN LIGHT COVE AS NOT TO INTERFERE WITH LIGHT DISTRIBUTION. 2. TOP OF COVE MOUNTED LIGHT FIXTURES SHALL BE FLUSH WITH TOP OF COVE LIP. PROVIDE MOUNTING HARWARE AS REQUIRED. 3. INDIVIDUAL FIXTURE RUN LENGTH SHALL NOT EXCEED 48' FOR CIRCUITING PURPOSES. REFER TO LIGHTING PLANS FOR CIRCUITING INFORMATION. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. Worldwide Facilities Group 3 COVE LIGHTING DETAIL NO.2 6 SCALE: NOT TO SCALE COVE LIGHTING DETAIL NO.3 SCALE: NOT TO SCALE General Motors Corporation Warren Technical Center Campus (2) 120V CIRCUITS VIA DMX RELAY PANEL L5 L5 L5 (2) 120V CIRCUITS VIA DMX RELAY PANEL L5 DE L8A L8A L8A DE L9 DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) L9 DATA L10 DATA J DE L10 L9 L5 L5 L5 DAISY CHAIN UTILIZING MANUFACTURER'S ENDTO-END CONNECTORS (TYP.) DATA DE L10 L10 DAISY CHAIN UTILIZING MANUFACTURER'S JUMPER CABLES L5 (1)CIRCUIT COUNTER CLOCKWISE AROUND COVE (1)CIRCUIT CLOCKWISE AROUND COVE L5 L5 L5 DATA ENABLER (TYP.) BY OTHERS (TYP.) L5 Level: DATA DE DATA L5 DE L5 DE DATA J DATA L5 L5 DATA L5 DE L5 L5 DE DATA L9 DE L10 (1)CIRCUIT COUNTER CLOCKWISE AROUND COVE L5 Structure ID: 4235 DATA DE L9 L10 DATA ENABLER (TYP.) L8A DE DATA L9 L8A L5 DE DATA L8A Site ID: 1563 L5 L5 L5 DAISY CHAIN UTILIZING MANUFACTURER'S JUMPER CABLES ELECTRICAL DETAILS DE DATA DATA BY OTHERS (TYP.) (1) CIRCUIT CLOCKWISE AROUND COVE NOTES: NOTES: 1. PROVIDE QUANTITY OF DATA ENABLERS AS REQUIRED FOR CONTINUOUS FIXTURE RUN. CONCEAL DATA ENABLER IN LIGHT COVE AS NOT TO INTERFERE WITH LIGHT DISTRIBUTION. 2. TOP OF COVE MOUNTED LIGHT FIXTURES SHALL BE FLUSH WITH TOP OF COVE LIP. PROVIDE MOUNTING HARWARE AS REQUIRED. 3. INDIVIDUAL FIXTURE RUN LENGTH SHALL NOT EXCEED 32' FOR CIRCUITING PURPOSES. REFER TO LIGHTING PLANS FOR CIRCUITING INFORMATION. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. 1. PROVIDE QUANTITY OF DATA ENABLERS AS REQUIRED FOR CONTINUOUS FIXTURE RUN. CONCEAL DATA ENABLER IN RING TRUSS AS NOT TO INTERFERE WITH LIGHT DISTRIBUTION. 2. PROVIDE MOUNTING HARWARE AS REQUIRED. 3. INDIVIDUAL FIXTURE RUN LENGTH SHALL NOT EXCEED 28' FOR CIRCUITING PURPOSES. REFER TO LIGHTING PLANS FOR CIRCUITING INFORMATION. COORDINATE WITH LIGHTING CONTROLS CONTRACTOR. WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 4 RIM COVE LIGHTING DETAIL NO.1 SCALE: NOT TO SCALE 7 RING LIGHTING DETAIL NO.1 SCALE: NOT TO SCALE NOT TO SCALE DATE 22MAY13 FILE PLOT DATE STAMP EP5−511 5/21/2013 12:17:10 PM WFG JOB NO. − SHEET NO. DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS 1" C. WITH PULL STRING AND BUSHING AT END TERMINATED IN ACCESSIBLE CEILING SPACE (TYP.) EXTEND 1" (MINIMUM) CONDUIT TO SECURITY PANEL. 3/4" C. FOR 120V BRANCH CIRCUIT SHOWN ON POWER PLANS FOR DOOR POWER SUPPLIES WALL POWER SUPPLY 3/4" C. PROVIDE 12"X12" JUNCTION BOX ON SECURE SIDE OF DOOR PSD JB PROVIDE CONNECTION TO FIRE ALARM SYSTEM AT CONTROLLED EXIT DOORS AND EMERGENCY EGRESS DOORS AS REQUIRED. GENERATOR ROOM GROUND BUS ACCESSIBLE CEILING (TYP.) PATCH HOLE TO MATCH FIRE RATING ACCESSIBLE CEILING (TYP.) CEILING TO GENERATOR PRIMARY SWITCHGEAR ROOM PERIMETER GROUND BUS TO BUILDING STEEL 3/4" C. RECESSED SINGLE-GANG BOX FOR ACCESS CONTROL ON NON-SECURE SIDE OF DOOR (PROVIDE ROUGH IN FOR ACCESS CONTROL ON BOTH SIDES OF DOOR WHERE SPECIFIED) 1"C. (TYP.) REQUEST TO EXIT DETECTOR (WHERE SPECIFIED) #4/0 AWG BARE COPPER #4/0 AWG INSULATED GREEN GROUND CABLE SUBSTATION 4-11/16" SQUARE, 2 1/8" DEEP DOUBLE GANG BOX WITH PLASTER RING (TYP.) TO BUILDING STEEL DOOR CONTACT N 1/2" FLEX CONDUIT, RECESSED IN FRAME. #4/0 AWG MAIN BONDING JUMPER COVER PLATE (TYP.) COVER PLATE (TYP.) 4-11/16" SQUARE, 2 1/8" DEEP DOUBLE GANG BOX WITH PLASTER RING (TYP.) G #4 AWG TO CONCRETE ENCASED ELECTRODE TO COUNTERPOISE GROUNDING BOND 1#4AWG TO EACH METAL PIPING SYSTEM PER NFPD70 250.166 (B), INCLUDING SUPPLY AND RETURN, STEAM, CHILLED WATER, COMPRESSED AIR, CONDENSATE. ACCESS CONTROL SYSTEM DIAGRAM 3 SCALE: NOT TO SCALE LOWER LEVEL GND-GROUNDING SYSTEM INTERCONNECTIONS 4 SCALE: NOT TO SCALE NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES 1. PROVIDE DATA CABLING AND FACEPLATE TO ACCOMMODATE (4) DATA CONNECTIONS. 2. COORDINATE TERMINATION LOCATION WITH OWNER. 3. PROVIDE LABELS TO DIFFERENTIATE GM NETWORK FROM AV NETWORK FOR ALL OUTLETS. NOTE: BOND AROUND ALL DOMESTIC WATER DIELECTRIC FITTINGS WITH 1#4. WATER SERVICE FLOOR NOTES: ONE PER PIPING SYSTEM GAS SERVICE 1 FLOOR 18" OR AS NOTED ELECTRIC STRIKE\ELECTRIC POWER TRANSFER DEVICE AS SPECIFIED 18" OR AS NOTED TO GROUNDING BAR IN FIBER ROOM SITE/BUILDING PLAN & NORTH ARROW TYPICAL TELECOM OUTLET DETAIL SCALE: NOT TO SCALE SEPARATELY DERIVED SOURCE TO NEXT FIRE ALARM JUNCTION BOX OR NAC PANEL. SEE FIRE ALARM RISER DIAGRAM DO NOT CONNECT THE IG CONDUCTOR TO ANY PART OF THE EQUIPMENT GROUND SYSTEM. ROUTE IG CONDUCTORS AS INDICATED. AHU SUPPLY FAN (TYP FOR 4) TYPICAL FIRE ALARM JUNCTION BOX OR NAC PANEL IN ELECTRICAL ROOM ROOM AHU RETURN FAN (TYP FOR 4) VFD 5 3 AI AI AR AR AR WF TS ELM FS TP 1 VFD 4 F AR N N N IG EG IG EG G TYP FOR 4 AHU'S CONDUIT AR UPSTREAM ELECTRICAL EQUIPMENT AS INDICATED ON THE ONE LINE DIAGRAM. FIRE ALARM INTELLIGENT DEVICES (MONITORING AND CONTROL) 2 IG N EG FEEDER SERVING IG PANELBOARD WITH 1#6 EG MINIMUM NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S FIRE ALARM VISUAL INDICATORS (STROBES) INDIVIDUAL AND COMBINATION TYPES 22733.000 NEUTRAL BUS N SUPPLIER DRAWN BY EG SUPPLIER CHECKED BY IG EG IG TO IG RECEPTACLE SUPPLIER PE/PM KEYED NOTES: 1 EQUIPMENT GROUND BUS ISOLATED/INSULATED GROUND BUS TYPICAL FIRE ALARM ZONE WIRING DIAGRAM FIRE ALARM AUDIBLE DEVICES-INDIVIDUAL AND COMBINATION TYPES PROVIDE ONE ADDRESSABLE INTERFACE (AI) FOR EACH OF THE FOLLOWING DEVICES: a. WATER FLOW SWITCH b. TAMPER SWITCH 2 TO NEXT FIRE ALARM JUNCTION BOX OR NAC PANEL FIRE ALARM INDICATING CIRCUIT FIRE ALARM SPEAKER CIRCUIT PROVIDE ONE ADDRESSABLE RELAY (AR) FOR EACH OF THE FOLLOWING DEVICES: REFER TO DOOR HARDWARE SPECIFICATIONS FOR LOCATIONS AND TYPES OF DOOR HARDWARE DEVICES. THREE PHASE IG BRANCH CIRCUIT PANELBOARD AS INDICATED ON PANEL SCHEDULE WITH EQUIPMENT GROUND BUS AND ISOLATED GROUND BUS CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com NOTE: THIS DIAGRAM IS FOR BASIC GROUNDING DESIGN INTENT AND DOES NOT NECESSARILY REFLECT ALL CONDITIONS ON THIS PROJECT. FOR POWER DISTRIBUTION DESIGN REFER TO ONE-LINE DIAGRAMS. a. FIRE / SMOKE DAMPER GENERAL NOTES: FIRE ALARM INTELLIGENT LOOP CIRCUIT CERTIFIED BY SUPPLIER PROJECT NO. A B C b. ELECTROPNEUMATIC SWITCH A REFER TO SPECIAL SYSTEMS PLANS FOR LOCATIONS AND NUMBER OF FIRE ALARM DEVICES. B WIRING REQUIREMENTS SHALL COMPLY WITH THE SYSTEM SUPPLIERS APPROVED SHOP DRAWINGS AND INSTALLATION INSTRUCTIONS. C REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF WATER FLOW AND SUPERVISORY SWITCHES. c. ELECTRIC LOCK 3 PROVIDE WIRING AND CONNECTIONS FROM ADDRESSABLE RELAY (AR) TO DEVICES FURNISHED AND INSTALLED BY OTHER TRADES SUCH AS FIRE DAMPERS, ELECTRIC DOOR LOCKS, FIRE/SMOKE VENTS AND EP SWITCHES. 4 ADDRESSABLE RELAY (AR) CONTACTS TO BE CONNECTED TO MOTOR STARTERS AND VARIABLE FREQUENCY DRIVE (VFD) MOTOR CONTROLLERS FOR SUPPLY AND RETURN FANS IN RESPECTIVE AIR HANDLING UNITS. 5 2 GND-IG PANEL GROUNDING Worldwide Facilities Group SCALE: NOT TO SCALE General Motors Corporation 12 "L PROVIDE REMOTE VISUAL INDICATOR FOR EACH DUCT SMOKE DETECTOR. LOCATE INDICATOR IN RESPECTIVE MECHANICAL ROOM OR RECESSED IN CORRIDOR CEILING TILE. COORDINATE WITH OTHER TRADES TO AVOID ANY INTERFERANCES Warren Technical Center Campus 1/4" Site ID: 1563 STAND-OFF 2" 3"W Structure ID: 4235 Level: COPPER BAR 5 EXOTHERMIC WELD OR CLAMP CONNECTION FA-TYPICAL FIRE ALARM WIRING DIAGRAM #6 AWG GROUNDING CONDUCTOR SCALE: NOT TO SCALE 6 INSULATOR 9/16" GND-GROUND BUS DETAIL - 12"L ELECTRICAL DETAILS SCALE: NOT TO SCALE WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE As indicated DATE 22MAY13 FILE PLOT DATE STAMP EP5−512 5/21/2013 12:17:12 PM − SHEET NO. DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS D E F G H I J K L M N O P Q R S T U SUPERVISORY ANNUNCIATION FACP BY DEVICE SOUND "FIRE ZONE" MESSAGE ON B, 1ST AND MZ FLOORS SOUND "FIRE ZONE" MESSAGE ON B, 1ST AND MZ FLOORS SOUND "FIRE ZONE" MESSAGE ON FLOOR OF SIGNAL ORIGIN AND FLOORS DIRECTLY ABOVE AND BELOW ACTIVATE VISIBLE NOTIFICATION DEVICES ON B, 1ST AND MZ FLOORS ACTIVATE VISIBLE NOTIFICATION DEVICES ON B, 1ST AND MZ FLOORS ACTIVATE VISIBLE NOTIFICATION DEVICES ON FLOOR OF SIGNAL ORIGIN AND FLOORSDIRECTLY ABOVE AND BELOW SOUND "SAFE ZONE" MESSAGE ON FLOORS OTHER THAN FLOOR OF SIGNAL ORIGIN AND FLOORS DIRECTLY ABOVE AND BELOW TRANSMIT TROUBLE SIGNAL CENTRAL STATION TRANSMIT SUPERVISORY SIGNAL CENTRAL STATION SHUNT TRIP OPERATION OF ELEVATOR POWER RECALL ELEVATORS TO PRIMARY RECALL FLOOR RECALL ELEVATORS TO SECONDARY RECALL FLOOR(S) ELEVATOR CAB FIRE HAT FLASH ANNUNCIATE ASSOCIATED INFORMATION ON ALL REMOTE LCD FAAPS CLOSE ASSOCIATED SMOKE DAMPER SHUT-DOWN ONLY THE ASSOCIATED AHU 1 MANUAL STATION - B FLOORS ONLY X 2 MANUAL STATION - 1ST & MZ FLOOR ONLY X 3 SMOKE DETECTORS - ELEVATOR LOBBIES B AND 1ST FLOOR ONLY X X X X X X X TRANSMIT ALARM SIGNAL TO CENTRAL STATION C PRINT CHANGE OF SYSTEM STATUS B TROUBLE ANNUNCIATION FACP BY DEVICE INITIATING DEVICE A ALARM ANNUNCIATION FACP BY DEVICE SYSTEM OUTPUT X X X X X X X X X X SITE/BUILDING PLAN & NORTH ARROW 4 SMOKE DETECTORS - ELEVATOR MACHINE ROOMS ONLY 5 DUCT MOUNTED SMOKE DETECTOR @ AHU (SUPPLY) FOR AHUs SERVING B THROUGH MEZZANINE FLOORS ONLY X X X X 6 DUCT MOUNTED SMOKE DETECTOR FOR SMOKE DAMPER OPERATION B THROUGH MEZZANINE FLOORS ONLY X X X X 7 HEAT DETECTOR - ELEVATOR MACHINE ROOMS ONLY X 8 WATERFLOW SWITCH - B FLOORS ONLY X 9 WATERFLOW SWITCH - 1ST AND MZ FLOOR ONLY X 10 WATERFLOW SWITCH - ELEVATOR MACHINE ROOMS ONLY X 11 SPRINKLER VALVE SUPERVISORY SWITCH X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X GM DISCLAIMER & TYPICAL NOTES X FIRE ALARM AC POWER FAIL X X X X 13 FIRE ALARM SYSTEM LOW BATTERY X X X X 14 OPEN CIRCUIT X X X X 15 GROUND FAULT X X X X 16 SLC/INITIATING DEVICE CIRCUIT FAULT X X X X 17 NOTIFICATION APPLIANCE CIRCUIT SHORT X X X X 18 LOSS OF VOLTAGE FOR ELEVATOR POWER SHUT DOWN CONTROL CIRCUIT X X NOT FOR CON STRU CTIO N X 12 X X X X X X X FIRE ALARM EVACUATION SEQUENCE: * IF FIRE ZONE MESSAGE ON FLOORS B THRU MEZZANINE - MESSAGE SHALL INDICATED BUILDING EVACUATION ON AFFECTED FLOORS NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E Load Red (Line) POWER PACK Blk Red (Load) Local Off Switch Worldwide Facilities Group General Motors Corporation Red Hot Wht Blk Neutral FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com White (Neutral) Blu WFG JOB NO. +24VDC Common Warren Technical Center Campus OCCUPANCY SENSOR Site ID: 1563 Control Output Structure ID: 4235 Level: 2 LTG-SINGLE OCC SENSOR SCALE: NOT TO SCALE ELECTRICAL DETAILS WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 12" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EP5−513 5/21/2013 12:17:13 PM WFG JOB NO. − SHEET NO. DATE 110VAC PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS TO ACCESS CONTROL SYSTEM EQUIPMENT PSD J ACCESS CONTROL DOOR GENERAL NOTES CEILING LINE 1. ALL RACEWAYS INCLUDING JUNCTION BOXES TO BE RECESSED UNLESS OTHERWISE NOTED. 2. DETERMINE EXACT RACEWAY ROUTING BASED ON FIELD CONDITIONS. 3. POWER FOR ELECTRIFIED DEVICES OBTAINED FROM POWER SUPPLIES AT ACCESS CONTROL PANEL ASSEMBLY UNLESS OTHERWISE NOTED. 4. PROVIDE WEATHER-PROOF (WP) JUNCTION BOXES IN EXTERIOR LOCATIONS 5. WIRE SIZES SHALL BE IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 6. COORDINATE REQUIREMENTS WITH ACHITECTURAL DOOR HARDWARE SCHEDULE AND SPECIFICATIONS. 1/2"C. DC _ DC _ 1/2" FLEX IN DOOR FRAME OR 1/2"C. OUTSIDE DOOR FRAME (TYP.) 3/4"C. PTD _ PTD 110VAC CR ELECTRIC EXIT DEVICE PSD _ 1910-1 HORN ELECTRIC EXIT DEVICE CEILING LINE CORE DOOR FOR POWER ROUTING (TYP FOR 2) DC _ DC _ DC _ DC _ DC _ DC _ DC _ DC _ GENERAL NOTES 1. REFER TO ACCESS CONTROL DOOR GENERAL NOTES. KEY SWITCH LEGEND CR CARD READER. DC _ DOOR CONTACT SWITCH PSD _ POWER SUPPLY FOR DOOR(S) WITH ELECTRICAL HARDWARE SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N JUNCTION BOX J PTD _ POWER TRANSFER DEVICE GENERAL NOTES TYPICAL ACCESS DOOR DETAIL NO.1 1 1. REFER TO ACCESS CONTROL DOOR GENERAL NOTES. SCALE: NOT TO SCALE GM DISCLAIMER & TYPICAL NOTES LEGEND DC _ PSD _ 110VAC TO ACCESS CONTROL SYSTEM EQUIPMENT PSD J 2 DOOR CONTACT SWITCH POWER SUPPLY FOR DOOR (S) WITH ELECTRICAL HARDWARE TYPICAL ACCESS DOOR DETAIL NO.2 SCALE: NOT TO SCALE CEILING LINE 1/2"C. DC _ DC _ ELECTRIC STRIKE 110VAC TO ACCESS CONTROL SYSTEM EQUIPMENT 1/2" FLEX IN DOOR FRAME OR 1/2"C. OUTSIDE DOOR FRAME (TYP.) J DO CEILING LINE CEILING LINE 3/4"C. PTD _ PTD CR DELAYED EGRESS EXIT DEVICE DELAYED EGRESS EXIT DEVICE DC _ CR DC _ (2) EA. @ PAIRS CORE DOOR FOR POWER ROUTING (TYP.) HC HC ACTIVATION SWITCHES GENERAL NOTES 1. REFER TO ACCESS CONTROL DOOR GENERAL NOTES. NO. PROJECT ARCH/ ENGR APPROVAL DATE LEGEND R E V I S I O N S CR CARD READER. DC _ DOOR CONTACT SWITCH CERTIFIED BY SUPPLIER PROJECT NO. GENERAL NOTES GENERAL NOTES PSD _ J POWER SUPPLY FOR DOOR(S) WITH ELECTRICAL HARDWARE 1. 1. SUPPLIER DRAWN BY JUNCTION BOX POWER TRANSFER DEVICE DC _ J TYPICAL RACCESS DOOR DETAIL NO.5 5 4 SCALE: NOT TO SCALE 22733.000 REFER TO ACCESS CONTROL DOOR GENERAL NOTES. REFER TO ACCESS CONTROL DOOR GENERAL NOTES. LEGEND LEGEND PTD _ DEPT. MGR/SUPR APPROVAL DOOR CONTACT SWITCH DO DOOR OPERATING EQUIPMENT JUNCTION BOX HC _ DOOR OPERATOR SWITCH TYPICAL ACCESS DOOR DETAIL NO.4 3 SCALE: NOT TO SCALE SUPPLIER CHECKED BY SUPPLIER PE/PM ACCESS DOOR DETAIL NO.3 CONSULTANT A/E FIRM INFO & LOGO SCALE: NOT TO SCALE SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com TO ACCESS CONTROL SYSTEM EQUIPMENT AND POWER SUPPLY FOR ELECTRIC STRIKE. TO ACCESS CONTROL SYSTEM EQUIPMENT AND POWER SUPPLY FOR ELECTRIC STRIKE. TO ACCESS CONTROL SYSTEM EQUIPMENT AND POWER SUPPLY FOR MAG LOCK. CONNECT TO FIRE ALARM PANEL. J CEILING LINE J J CEILING LINE 1/2"C. 1/2"C. 1/2"C. DC DC MD DC General Motors Corporation ELM 1/2" FLEX IN DOOR FRAME OR 1/2"C. OUTSIDE DOOR FRAME (TYP.) 1/2" FLEX IN DOOR FRAME OR 1/2"C. OUTSIDE DOOR FRAME Warren Technical Center Campus Site ID: 1563 3/4"C. ELECTRIC STRIKE Worldwide Facilities Group CEILING LINE 3/4"C. CR 3/4"C. CR Structure ID: 4235 CR Level: ELECTRIC STRIKE GENERAL NOTES 1. GENERAL NOTES REFER TO ACCESS CONTROL DOOR GENERAL NOTES. 1. GENERAL NOTES REFER TO ACCESS CONTROL DOOR GENERAL NOTES. 1. ELECTRICAL DETAILS REFER TO ACCESS CONTROL DOOR GENERAL NOTES. LEGEND CR CARD READER. MOUNT JUNCTION BOX ON LATCH SIDE OF DOOR WHEN POSSIBLE. DC _ DOOR CONTACT SWITCH CR CARD READER. MOUNT ON JUNCTION BOX ON LATCH SIDE OF DOOR WHEN POSSIBLE. JUNCTION BOX DC _ DOOR CONTACT SWITCH J LEGEND J LEGEND JUNCTION BOX CR CARD READER. MOUNT ON JUNCTION BOX ON LATCH SIDE OF DOOR WHEN POSSIBLE. DC _ DOOR CONTACT SWITCH ELM MAG LOCK HARDWARE MD MOTION DETECTOR - CEILING OR WALL MOUNTED J 6 7 TYPICAL ACCESS DOOR DETAIL NO.7 SCALE: NOT TO SCALE 8 TYPICAL ACCESS DOOR DETAIL NO.8 SCALE: NOT TO SCALE WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author JUNCTION BOX TYPICAL ACCESS DOOR DETAIL NO.6 SCALE: NOT TO SCALE WFG PE/PM SCALE 12" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EP5−514 5/21/2013 12:17:15 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: ELECTRICAL DETAILS WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 12" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EP5−515 5/21/2013 12:17:16 PM − SHEET NO. DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS BASEMENT SUBSTATION NO. 6A BASEMENT SUBSTATION NO. 6B A-4 B-4 80E 80E SUB 6A 750/1000 KVA 13.2KV-480Y/277V SUB 6B 750/1000 KVA 13.2KV-480Y/277V 1600AF 1200AT SITE/BUILDING PLAN & NORTH ARROW KEYED NOTES PROVIDE QUANTITY OF CIRCUITS AS REQUIRED 1600AF 1200AT E501 E502 6A-2 800AF 400AT 6A-4 6B-2 6B-3 800AF TIE 1600AF 1000AT 800AF 600AT 800AF 800AT E503 DATA CABLING TO A/V MACHINE ROOM FOR RELAY CONTROL 800AF 800AT NEW A/V PANELBOARD SHALL CONTAIN ISOLATED GROUND BUS. MOUNT FUSED DISCONNECT WITHIN LINE OF SIGHT OF PROJECTOR. VERIFY THE ORIGINATION OF THE NORMAL POWER SOURCE OF THE EXISITNG AUTOMATIC TRANSFER SWITCH 'ATS-1'. NEW SWITCH 'ATS-2' NORMAL POWER SOURCE SHALL ORIGINATE FROM THE SAME SUBSTATION BRANCH AS THE EXISTING ATS. NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES TYPICAL LIGHTING RELAY PANEL DETAIL SPARE SPARE SPARE TO LIGHT FIXTURES/ RECEPTACLES LRP 480Y/277V 3PH,4W BUS SPACE 800AF 6B-1 SPACE SPACE 800AF 800AT 6A-3 LP-RING 225A SPACE 6A-1 480Y/277V 3PH,4W BUS 600A 480V 3P,3W T-B-11 300 KVA 480 ∆-208Y/120V 30A 30A 60A 30A 30A 30A 30A 200A 200A 20A 20A 40A 20A 20A 10A 20A 200A 200A 100A 125A 100A 100A 100A 200A 200A 200A 200A 100A 100A 400A 400A 400A 400A SPACE FA-BL21 400A FA-BL22 400A LP-B-8 RELOCATED 60A/3/45A T-B-8 30 KVA 480V-208Y/120V 60A/3/40A FABL-12 T 1 1/2 HP (E)EF-6 2 SPEED ELEVATOR CONTROLLER FA-BP11A FABL-13 30A, 3P VFD N FA-L22 T-LP-RING 75 KVA 480V-208Y/120V 3 PHASE E E501 TO TUNNEL LP-B-8E FA-BP11 200A T-LP-AV 150 KVA 480V-208Y/120V 3 PHASE 30A/3/15A DEPT. MGR/SUPR APPROVAL CERTIFIED BY 22733.000 30A, 3P FA-L21 PROJECT ARCH/ ENGR APPROVAL DATE SUPPLIER PROJECT NO. ATS-1 100A SPD-1 NO. R E V I S I O N S SPARE B-11 DOME 1ST FL J-CLOSET SPACE SPACE 800A, 480V, 3PH, 3W SPACE 400A 1200A, 208Y/120V, 3PH, 4W 400A BASEMENT SPACE 200A MCC-1 SPACE 125A BASEMENT 800A, 480Y/277V, 3PH, 4W SPACES 100A 800A, 480Y/277V, 3PH, 4W PDP-1 BASEMENT 200A LDP-2 100A BASEMENT PDP-PV MAIN FOUNTAIN VAULT 1000A LDP-1 100A WFG JOB NO. HWP-1 30A, 3P VFD 30A, 3P VFD 30A, 3P VFD 30A, 3P VFD SUPPLIER DRAWN BY VFD SUPPLIER CHECKED BY HWP-2 RAFAHU-3 SAFAHU-3 CHWP-1 CHWP-2 SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO ATS-2 E503 45A 100A FEEDER LP-AV 400A L E502 E502 J 100A FEEDER (TYP.) 60A, 3P 60A, 3P J (TYP.) 60A, 3P T-LP-M 30 KVA 480V-208Y/120V 3 PHASE J SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com LP-RING 225A 60A, 3P LP-M-1E SOUTH AUDITORIUM PROJECTOR (REDUNDANT) NORTH AUDITORIUM PROJECTOR (REDUNDANT) (E)EF-4 AUDITORIUM EXHAUST Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: ELECTRICAL ONE−LINE DIAGRAM WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE 12" = 1'-0" DATE 22MAY13 FILE PLOT DATE STAMP EP6−511 5/21/2013 12:17:17 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS Branch Panel: NEW SPD-1 Branch Panel: LP-B-8E Location: Supply From: LDP-1 Mounting: Surface Enclosure: Type 1 Volts: 480Y/277 Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: Location: Supply From: T-B-8 Mounting: Surface Enclosure: Type 1 65,000 MAIN CIRCUIT BREAKER 125 A 125 A Notes: CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Volts: 208Y/120 Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: MAIN LUGS ONLY Mains Rating: 100 A MCB Rating: 100 A Notes: Circuit Description RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD Spare Spare Spare Spare Spare Spare Space Space Space Trip Poles A B C Poles 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 --0 VA 0 VA ---0 VA 0 VA ---0 VA 0 VA -3000 VA 3000 VA 3000 VA Total Load: 11 A 11 A 11 A Total Amps: Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ---- Circuit Description RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD Spare Spare Spare Spare Spare Spare Space Space Space CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 CKT 1 3 5 7 9 11 13 15 17 19 21 23 Circuit Description EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD DRY PIPE COMPRESSOR Demand Factor 125.00% B C 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 0 VA 750 VA 0 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 5250 VA 44 A 5250 VA 44 A 200 VA 750 VA 5450 VA 45 A Poles 1 1 1 1 1 1 1 1 1 1 1 1 Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Circuit Description EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD Spare Spare EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD CKT 2 4 6 8 10 12 14 16 18 20 22 24 Legend: Load Classification Mechanical Equipment Existing Load Connected Load 9000 VA A 750 VA 750 VA SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES Legend: Load Classification Existing Load Trip Poles 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 Total Load: Total Amps: Estimated Demand 11250 VA Connected Load 200 VA 15750 VA Demand Factor 80.00% 125.00% Estimated Demand 160 VA 19688 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 9000 VA 11250 VA 11 A 14 A Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 15950 VA 19848 VA 44 A 55 A Notes: Notes: Branch Panel: NEW FA-BP11 Location: Supply From: Mounting: Enclosure: Branch Panel: LP-B-8 Volts: 208Y/120 Phases: 3 Wires: 4 MULTI-PURPOSE ROOM 115 LDP-2 Surface Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: Location: Supply From: LDP-2 Mounting: Surface Enclosure: Type 1 MATCH EXISTING MCB 225 A 200 A Notes: Volts: 208Y/120 Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: MAIN LUGS ONLY Mains Rating: 125 A MCB Rating: 125 A NO. PROJECT ARCH/ ENGR APPROVAL DATE Notes: DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 Circuit Description Trip Poles A B C 1500... 1000... FA-BP11A 125 A 3 1500... 1000... 1500... 1000... MULTI-PURPOSE ROOM 115 LIGHTING STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL STAGE LIGHT PIPE RECEPTS VIA RELAY PANEL Spare Spare Spare Spare Spare RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS Space Space Space Space Space Space 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 ------------Total Load: Total Amps: 576 VA 1000... 1162... 1000... 1500... 1000... 1660... 1360... 948 VA 1360... 1414... 1360... 1414... 1360... 948 VA 1526... 1660... 100 VA 1500... 900 VA 1162... 900 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 13770 VA 116 A 0 VA 14506 VA 122 A 0 VA 0 VA 12534 VA 104 A Poles 1 1 1 1 1 1 1 1 1 1 1 1 Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Circuit Description STAGE LIGHTING RECEPTS VIA RELAY PANEL STAGE LIGHTING RECEPTS VIA RELAY PANEL STAGE LIGHTING RECEPTS VIA RELAY PANEL STAGE LIGHTING RECEPTS VIA RELAY PANEL STAGE LIGHTING RECEPTS VIA RELAY PANEL STAGE LIGHTING RECEPTS VIA RELAY PANEL STAGE COVE LTG RECEPTS VIA RELAY PANEL STAGE COVE LTG RECEPTS VIA RELAY PANEL STAGE COVE LTG RECEPTS VIA RELAY PANEL STAGE COVE LTG RECEPTS VIA RELAY PANEL STAGE COVE LTG VIA RELAY PANEL ACCESS CONTROL DOOR POWER SUPPLY 2 30 A RECEPT - STAGE 1 1 1 1 1 1 1 1 1 1 ------- 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ------- Spare Spare Spare Spare Spare RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS RESERVED FOR EXISTNG LOADS Space Space Space Space Space Space CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 CKT 1 3 5 7 9 11 13 15 17 19 21 23 Circuit Description EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Poles 1 1 1 1 1 1 1 1 1 1 Existing Load 500 A 2 Total Load: Total Amps: A 750 VA 750 VA B 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 523 VA 6000 VA 51 A 5773 VA 49 A C Poles 1 1 750 VA 750 VA 1 1 1 750 VA 750 VA 1 1 1 750 VA 750 VA 1 1 1 750 VA 0 VA -5250 VA 44 A Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A -- Circuit Description EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD EXISTING LOAD MECHANICAL EQUIPMENT ROOM 002 Space CKT 2 4 6 8 10 12 14 16 18 20 22 24 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Legend: Load Classification Lighting Mechanical Equipment Existing Load Connected Load 200 VA 323 VA 16500 VA Demand Factor 100.00% 80.00% 125.00% Estimated Demand 200 VA 258 VA 20625 VA FIRM INFO & LOGO Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 17023 VA 21083 VA 47 A 59 A Worldwide Facilities Group Notes: General Motors Corporation Warren Technical Center Campus Site ID: 1563 Legend: Structure ID: 4235 Load Classification Power Lighting Receptacle Existing Load Connected Load 100 VA 26910 VA 1800 VA 12000 VA Demand Factor 100.00% 100.00% 100.00% 125.00% Estimated Demand 100 VA 26910 VA 1800 VA 15000 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: Level: 40810 VA 43810 VA 113 A 122 A Notes: ELECTRICAL PANEL SCHEDULES WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE DATE 22MAY13 FILE PLOT DATE STAMP EB7−711 5/21/2013 12:15:48 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS Branch Panel: NEW FA-BL12 Location: Supply From: Mounting: Enclosure: Branch Panel: NEW FA-BL13 Volts: 208Y/120 Phases: 3 Wires: 4 COAT ROOM 118 NEW FA-BL21 Surface Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: Location: Supply From: Mounting: Enclosure: 22,000 MCB 100 A 100 A Notes: CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Volts: 208Y/120 Phases: 3 Wires: 4 SECURITY CLOSET 127D NEW FA-BL22 SURFACE Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: 22,000 MAIN CIRCUIT BREAKER 125 A 125 A Notes: Circuit Description UH-1 MENS TOILET AUTO FLUSH/FAUCET RECEPT MENS TOILET AUTO FLUSH/FAUCET RECEPT COAT ROOM 118, MENS TLT 120, 121 LIGHTING WEST LOBBY, CANOPY LIGHTING Spare Spare Spare Spare Spare RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS Trip Poles A 20 A 1 230 VA 1127... 20 A 1 20 A 1 20 A 1 755 VA 400 VA 20 A 1 20 A 1 20 A 1 0 VA 0 VA 20 A 1 20 A 1 20 A 1 0 VA 0 VA 20 A 1 20 A 1 20 A 1 750 VA 750 VA 20 A 1 20 A 1 4012 VA Total Load: 33 A Total Amps: B C Poles 1 1060... 100 VA 1 1560... 500 VA 1 1 168 VA 0 VA 1 0 VA 0 VA 1 1 0 VA 0 VA 1 0 VA 0 VA 1 1 750 VA 750 VA 1 750 VA 750 VA 1 1 750 VA 750 VA 1 750 VA 750 VA 1 4328 VA 5060 VA 36 A 43 A Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Circuit Description EF-2 WEST DOOR CHEXIT ADA DOOR WEST LOBBY FLAT PANEL TV Spare Spare Spare Spare Spare Spare RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Legend: Load Classification Power Lighting Mechanical Equipment Receptacle Appliance Existing Load Connected Load 100 VA 923 VA 3757 VA 720 VA 400 VA 7500 VA Demand Factor 100.00% 100.00% 80.00% 100.00% 100.00% 125.00% Estimated Demand 100 VA 923 VA 3006 VA 720 VA 400 VA 9375 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 13400 VA 14524 VA 37 A 40 A CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Circuit Description UH-2 RECEPTS - GREEN ROOM RECEPTS - COPIER, GREEN ROOM WOMENS TOILET AUTO FLUSH/FAUCET,... WOMENS TOILET AUTO FLUSH/FAUCET,... GREEN RM, COPY RM, WOMEN TLT LTG FLAT PANEL TV'S Spare Spare Spare Spare Spare Spare RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS Trip Poles 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 20 A 1 Total Load: Total Amps: A 230 VA 7567... B C 720 VA 3000... 1180... 3000... 1060... 100 VA 1360... 500 VA 452 VA 168 VA 600 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 750 VA 12557 VA 106 A 10080 VA 85 A 750 VA 750 VA 9300 VA 78 A Poles 1 Trip 20 A Circuit Description EF-1 2 40 A IWH-1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A EAST EXTERIOR DOOR SECURITY ADA DOOR EAST LOBBY EAST VESTIBULE AND CANOPY LIGHTING Spare Spare Spare Spare Spare Spare Spare RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS RESERVED FOR EXISTING LOADS CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Legend: Load Classification Power Lighting Mechanical Equipment Receptacle Appliance Existing Load Notes: Connected Load 100 VA 620 VA 15997 VA 2620 VA 600 VA 12000 VA Demand Factor 100.00% 100.00% 80.00% 100.00% 100.00% 125.00% Estimated Demand 100 VA 620 VA 12798 VA 2620 VA 600 VA 15000 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 31937 VA 31738 VA 89 A 88 A SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES Notes: Branch Panel: NEW FA-BL21 Location: Supply From: Mounting: Enclosure: Branch Panel: NEW FA-BL22 Volts: 208Y/120 Phases: 3 Wires: 4 MECH EQUIP ROOM 203 LDP-2 Surface Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: Location: Supply From: Mounting: Enclosure: 22,000 MAIN CIRCUIT BREAKER 400 A 400 A Notes: CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 Volts: 208Y/120 Phases: 3 Wires: 4 MECH EQUIP ROOM 202 LDP-2 Surface Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: 22,000 MAIN CIRCUIT BREAKER 400 A 400 A Notes: Circuit Description Trip Poles A 4012... NEW FA-BL12 100 A 3 AHU LIGHTS UH-4 20 A 20 A 1 1 (R)DWH-1 30 A 2 L3 LIGHTING RECEPT VIA RELAY PANEL L3 LIGHTING RECEPT VIA RELAY PANEL L3 LIGHTING RECEPT VIA RELAY PANEL L3 LIGHTING RECEPT VIA RELAY PANEL L3 LIGHTING RECEPT VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL EAST ENTRY LIGHTING VIA RELAY PANEL 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 1 1 1 1 1 1 1 1 1 1 1 1 FCU-1 20 A 3 B 0 VA C Poles 1 4328... 200 VA 1 5060... 1610... 1 Circuit Description UH-6 AHU LIGHTS CP-1,3, & 4 200 VA 756 VA 403 VA 756 VA 3 20 A FPB-2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ----1 1 1 1 1 1 1 1 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ----20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A OUTER RIM COVE LIGHTING VIA RELAY PANEL OUTER RIM COVE LIGHTING VIA RELAY PANEL OUTER RIM COVE LIGHTING VIA RELAY PANEL OUTER RIM COVE LIGHTING VIA RELAY PANEL OUTER RIM COVE LIGHTING VIA RELAY PANEL O. RIM COVE & ENTRY TRK LTG VIA RELAY... INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL INNER RIM COVE LIGHTING VIA RELAY PANEL WEST ENTRY LIGHTING VIA RELAY PANEL ACCESS CONTROL DOOR POWER SUPPLY MOTOIZED SHADES - BOARDROOM FLOOR BOXES - BOARD ROOM Spare Spare Spare Spare Spare Spare Spare Spare Space Space Space Space RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD 2250... 756 VA 2250... 1100... 1360... 1424... 1360... 1100... 1360... 1100... 1360... 1100... 1360... 1424... 1200... 1200... 1200... 1200... 1200... 1200... 1200... 1200... 1200... 1200... 1200... 1200... 862 VA 862 VA 720 VA 200 VA 720 VA 200 VA 720 VA 360 VA Spare Spare Spare Spare Spare Spare Spare Spare Space Space Space Space RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD Trip 20 A 20 A 20 A 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA --0 VA 0 VA --0 VA 0 VA --0 VA 0 VA --0 VA 0 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 21382 VA 21151 VA 25140 VA Total Load: 178 A 176 A 210 A Total Amps: CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 Circuit Description RECEPT - GLYCOL PUMPS BASEMENT Trip 20 A Poles A 1 864 VA 870 VA B C 12557... 200 VA NEW FA-BL13 125 A 3 10080... 403 VA 9300... 1360... 2904... 1360... CRU-1 20 A 3 2904... 1360... 2904... 1360... 756 VA 1360... FBP-1 20 A 3 756 VA 1444... 756 VA 1444... Spare Spare Spare Spare Spare Spare Spare RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD Space Space Space Space Space 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 0 VA 0 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA 20 A 1 750 VA 750 VA --0 VA 0 VA --0 VA 0 VA --0 VA 0 VA --0 VA 0 VA --0 VA 0 VA 23358 VA 22137 VA 21447 VA Total Load: 196 A 185 A 179 A Total Amps: Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ------ Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ------ Circuit Description RC-2 AHU LIGHTS UH-3 L3 LIGHTING RECEPTS VIA RELAY PANEL L3 LIGHTING RECEPTS VIA RELAY PANEL L3 LIGHTING RECEPTS VIA RELAY PANEL L3 LIGHTING RECEPTS VIA RELAY PANEL L3 LIGHTING RECEPTS VIA RELAY PANEL WEST BOARDROOM LIGHTING VIA RELAY... EAST BOARDROOM LIGHTING VIA RELAY... Spare Spare Spare Spare Spare Spare Spare RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD RESERVED FOR EXISTING LOAD Space Space Space Space Space CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 NO. PROJECT ARCH/ ENGR APPROVAL DATE R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Worldwide Facilities Group Legend: Load Classification Power Lighting Mechanical Equipment Receptacle Appliance Existing Load Connected Load 100 VA 10508 VA 29114 VA 2620 VA 600 VA 24000 VA Demand Factor 100.00% 100.00% 80.00% 100.00% 100.00% 125.00% Estimated Demand 100 VA 10508 VA 23291 VA 2620 VA 600 VA 30000 VA General Motors Corporation Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 66942 VA 67119 VA 186 A 186 A Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Notes: Legend: Load Classification Power Lighting Mechanical Equipment Receptacle Appliance Existing Load DEPT. MGR/SUPR APPROVAL Level: Connected Load 860 VA 31495 VA 14698 VA 720 VA 400 VA 19500 VA Demand Factor 100.00% 100.00% 80.00% 100.00% 100.00% 125.00% Estimated Demand 860 VA 31495 VA 11758 VA 720 VA 400 VA 24375 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 67673 VA 69608 VA 188 A 193 A ELECTRICAL PANEL SCHEDULES Notes: WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE DATE 22MAY13 FILE PLOT DATE STAMP EB7−712 5/21/2013 12:15:50 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS Branch Panel: NEW FA-L21 Location: Supply From: Mounting: Enclosure: Branch Panel: NEW FA-L22 Volts: 480Y/277 Phases: 3 Wires: 4 MECH EQUIP ROOM 203 LDP-1 Surface Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: Location: Supply From: Mounting: Enclosure: 65,000 MCB 400 A 400 A Notes: PROVIDE PANEL WITH DOUBLE LUGS CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Circuit Description RAF-1 Trip Poles 20 A 3 A 2550... 5845... B C 2550... 5845... Poles Trip 3 40 A Circuit Description SAF-1 2550... 5845... 20 A 3 2550... 5845... 3 40 A SAF-4 1 1 1 1 1 1 ---- 20 A 20 A 20 A 20 A 20 A 20 A ---- Spare Spare Spare Spare Spare Spare Space Space Space 2550... 5845... 5462... ATS-2 45 A 0 VA 3 3600... 0 VA 4800... Spare Spare Spare Space Space Space A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: 65,000 MCB 225 A 200 A Notes: PANEL SHALL CONTAIN DOUBLE LUGS 2550... 5845... RAF-4 Volts: 480Y/277 Phases: 3 Wires: 4 MECH EQUIP ROOM 202 PDP-1 Surface Type 1 20 A 1 20 A 1 20 A 1 ------Total Load: Total Amps: 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 22252 VA 81 A 0 VA 0 VA 0 VA 21590 VA 79 A 20390 VA 74 A CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Circuit Description SAF-2 Trip Poles 40 A 3 B C 5845... 2550... Poles Trip Circuit Description 3 20 A RAF-2 1 20 A SP-1 & 2 3 45 A ATS-2 (EMERGEMCY FEED) 1 1 1 1 1 1 1 1 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Spare Spare Spare Spare Spare Spare Spare Spare 5845... 2550... 0 VA (E)60A RECEPTACLE 60 A 0 VA 2019... (E)EF-4 20 A Spare Spare Spare Spare Spare Spare 20 A 20 A 20 A 20 A 20 A 20 A 1828... 3 1 1 1 1 1 1 2019... 0 VA 0 VA 0 VA 2019... 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 3 20 Total Amps: Legend: A 5845... 2550... 0 VA 0 VA 0 VA 12242 VA 44 A 0 VA 10414 VA 38 A 0 VA 0 VA 10414 VA 38 A CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Legend: Load Classification Power Lighting Mechanical Equipment Existing Load Connected Load 0 VA 7662 VA 50570 VA 6000 VA Demand Factor 0.00% 100.00% 80.00% 125.00% Estimated Demand 0 VA 7662 VA 40456 VA 7500 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: Load Classification Power Mechanical Equipment 64232 VA 55618 VA 77 A 67 A Notes: Connected Load 0 VA 33071 VA Demand Factor 0.00% 80.00% Estimated Demand 0 VA 26456 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 33071 VA 26456 VA 40 A 32 A SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES Notes: Branch Panel: NEW LP-AV Location: Supply From: Mounting: Enclosure: Branch Panel: NEW LP-M-1E Volts: 208Y/120 Phases: 3 Wires: 4 MECH EQUIP ROOM 202 T-LP-AV Surface Type 1 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: Location: Supply From: Mounting: Enclosure: 10,000 MAIN CIRCUIT BREAKER 400 A 400 A Notes: PROVIDE INTEGRAL ISOLATED GROUND BUS AND ISOLATED GROUND CONDUCTOR FROM NEW TRANSFORMER. MECH EQUIP ROOM 202 T-LP-M Surface Type 1 Volts: 208Y/120 Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: 10,000 MAIN CIRCUIT BREAKER 100 A 100 A Notes: NO. CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 Circuit Description A/V RACK A/V RACK A/V RACK A/V RACK A/V RACK A/V RACK RECEPT - RING SPEAKER RECEPT - RING PROJECTOR RECEPT - RING SPEAKER RECEPT - RING SPEAKER RECEPT - RING PROJECTOR RECEPT - RING SPEAKER Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Poles 1 1 1 1 1 1 1 1 1 1 1 1 A 1000... 1000... B C 1000... 1000... 1000... 1000... 1000... 1000... 1000... 700 VA 1000... 500 VA 500 VA 1500... 1500... 500 VA 500 VA 500 VA 500 VA 1500... 1500... 500 VA 500 VA 500 VA 4560... 1500... AUDITORIUM PROJECTORS SOUTH 100 A 3 4560... 500 VA 4560... 1200... 4560... 1200... AUDITORIUM PROJECTORS NORTH 100 A 3 4560... 1200... 4560... 1180... AV SPEAKERS AV SPEAKERS AV SPEAKERS AV SPEAKERS 20 A 20 A 20 A 20 A 1 1 1 1 AV SPEAKERS 20 A 2 AV SPEAKERS 20 A 2 AV SPEAKERS 20 A 2 AV SPEAKERS 20 A 2 BOARDROOM MOTORIZED SCREEN FLOOR BOX BOARDROOM FLOOR BOX BOARDROOM PTZ CAMERAS RECEPTS - DIPLAY AREA STEPS RECEPTS - DIPLAY AREA STEPS MOTORIZED SCREEN Spare Spare Spare Spare Spare 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 1 1 1 1 1 1 1 1 1 1 1 1 Total Amps: 960 VA 680 VA 960 VA 1000... 960 VA 860 VA 960 VA 960 VA 480 VA 960 VA 480 VA 960 VA 480 VA 960 VA 480 VA 480 VA 480 VA 480 VA 480 VA 480 VA 480 VA 480 VA 480 VA 480 VA 500 VA 480 VA 360 VA 480 VA 360 VA 480 VA 360 VA 1080... 540 VA 1080... 540 VA 500 VA 500 VA 1000... 0 VA 1000... 0 VA 0 VA 0 VA 0 VA 0 VA 29700 VA 252 A 0 VA 27300 VA 232 A 0 VA 0 VA 24060 VA 201 A Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A Circuit Description A/V RACK A/V RACK A/V RACK A/V RACK BOARDROOM PROJECTOR AND LIFT RECEPT - RING SPEAKER RECEPT - RING PROJECTOR RECEPT - RING SPEAKER RECEPT - RING SPEAKER RECEPT - RING PROJECTOR RECEPT - RING SPEAKER RECEPT - RING SPEAKER RECEPT - RING PROJECTOR RECEPT - RING SPEAKER AV SPEAKERS AV SPEAKERS AV SPEAKERS RECEPTS - CONTROL CONSOLE RECEPTS - CONTROL CONSOLE RECEPTS - CONTROL CONSOLE RECEPTS - CONTROL CONSOLE AV SPEAKERS AV SPEAKERS AV SPEAKERS AV SPEAKERS 2 20 A AV SPEAKERS 2 20 A AV AV SPEAKERS 2 20 A AV SPEAKERS 2 20 A AV SPEAKERS 1 1 1 1 1 1 1 1 1 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A PTZ CAMERAS, STAGE RECEPT, STORAGE STAGE RECEPTS MOTORIZED SCREEN A/V RACK A/V RACK Spare Spare Spare Spare CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 Circuit Description INNER RIM COVE EM LTG VIA RELAY PANEL INNER RIM COVE EM LTG VIA RELAY PANEL INNER RIM COVE EM LTG VIA RELAY PANEL STAGE COVE EM LTG VIA RELAY PANEL Spare Spare Spare Spare Space Space Space RESERVED FOR EXISTING LIGHTING RESERVED FOR EXISTING LIGHTING RESERVED FOR EXISTING LIGHTING RESERVED FOR EXISTING LIGHTING Trip Poles A B C Poles 20 A 1 1600... 556 VA 1 20 A 1 1600... 500 VA 1 20 A 1 1600... 200 VA 1 20 A 1 1526... 280 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 20 A 1 0 VA 0 VA 1 --0 VA 0 VA ---0 VA 0 VA ---0 VA 0 VA -20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 20 A 1 750 VA 750 VA 1 5462 VA 3600 VA 4800 VA Total Load: 47 A 30 A 42 A Total Amps: Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ---20 A 20 A 20 A 20 A Circuit Description EAST ENTRY COVE EM LTG VIA RELAY PANEL WEST ENTRY COVE EM LTG VIA RELAY PANEL DRY PIPE COMPRESSOR BOARDROOM EM LTG VIA RELAY PANEL Spare Spare Spare Spare Space Space Space RESERVED FOR EXISTING LIGHTING RESERVED FOR EXISTING LIGHTING RESERVED FOR EXISTING LIGHTING RESERVED FOR EXISTING LIGHTING CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Connected Load 7662 VA 200 VA 6000 VA Demand Factor 100.00% 80.00% 125.00% Estimated Demand 7662 VA 160 VA 7500 VA CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: DEPT. MGR/SUPR APPROVAL R E V I S I O N S Legend: Load Classification Lighting Mechanical Equipment Existing Load PROJECT ARCH/ ENGR APPROVAL DATE 13862 VA 15322 VA 38 A 43 A Worldwide Facilities Group Notes: General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: Legend: Load Classification Receptacle AV Equipment Connected Load 1080 VA 79980 VA Demand Factor 100.00% 100.00% Estimated Demand 1080 VA 79980 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 81060 VA 81060 VA 225 A 225 A ELECTRICAL PANEL SCHEDULES Notes: WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE DATE 22MAY13 FILE PLOT DATE STAMP EB7−713 5/21/2013 12:15:51 PM WFG JOB NO. SHEET NO. − DATE PROJECT ARCH/ ENGR APPROVAL ISSUED FOR DEPT. MGR/SUPR APPROVAL 22MAY13 BIDS Branch Panel: LP-RING Location: Supply From: T-LP-RING Mounting: Surface Enclosure: Type 1 Volts: 208Y/120 Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: Mains Rating: MCB Rating: 10,000 MCB 225 A 200 A Notes: CKT 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 Circuit Description RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... TYPE L5 RING LIGHTS VIA LIGHTING RELAY... TYPE L5 RING LIGHTS VIA LIGHTING RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... Spare Spare Spare Spare Spare Spare Space Space Space Space Space Space Space Space Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A --------- Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 --------- Total Load: Total Amps: A 180 VA 180 VA B C 1027... 1027... 1027... 1027... 1027... 1027... 707 VA 707 VA 180 VA 180 VA 1027... 1027... 1027... 1027... 1027... 1027... 707 VA 707 VA 180 VA 180 VA 1027... 1027... 1027... 1027... 1027... 1027... 707 VA 707 VA 180 VA 180 VA 1027... 1027... 1027... 1027... 1027... 1027... 707 VA 707 VA 1400... 1400... 1400... 1400... 180 VA 180 VA 1027... 1027... 1027... 1027... 1027... 1027... 707 VA 707 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 0 VA 15204 VA 128 A 0 VA 13818 VA 115 A 0 VA 16258 VA 137 A Poles 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ---------- Trip 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A ---------- Circuit Description RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... TYPE L5 RING LIGHTS VIA LIGHTING RELAY... TYPE L5 RING LIGHTS VIA LIGHTING RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... RING LIGHTING RECEPTACLE VIA RELAY... Spare Spare Spare Spare Spare Spare Space Space Space Space Space Space Space Space Space CKT 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 SITE/BUILDING PLAN & NORTH ARROW NOT FOR CON STRU CTIO N GM DISCLAIMER & TYPICAL NOTES Legend: Load Classification Lighting Connected Load 45280 VA Demand Factor 100.00% Estimated Demand 45280 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 45280 VA 45280 VA 126 A 126 A Notes: NO. PROJECT ARCH/ ENGR APPROVAL DATE DEPT. MGR/SUPR APPROVAL R E V I S I O N S CERTIFIED BY SUPPLIER PROJECT NO. 22733.000 SUPPLIER DRAWN BY SUPPLIER CHECKED BY SUPPLIER PE/PM CONSULTANT A/E FIRM INFO & LOGO SMITHGROUPJJR, INC 500 GRISWOLD SUITE 1700 DETROIT, MI 48226 T 313.983.3600 F 313.983.3636 www.smithgroupjjr.com Worldwide Facilities Group General Motors Corporation Warren Technical Center Campus Site ID: 1563 Structure ID: 4235 Level: ELECTRICAL PANEL SCHEDULES WFG PE/PM WFG JOB NO N. WEINGARTZ DRAWN BY 1200912 SHEET NUMBER Author SCALE DATE 22MAY13 FILE PLOT DATE STAMP EB7−714 5/21/2013 12:15:52 PM