WATTSTOPPER ARCHITECTURAL DIMMING INFRASTRUCTURE & ENCLOSURES EMERGENCY LIGHTING SHUNT RELAY VA-RRU-1-120V (-277V) Description Legrand’s Emergency Lighting Shunt Relay may be used to place selected loads into emergency override as long as there is emergency power provided to the specified modules or loads. Using the VA-RRU relay allows emergency override status to initiate automatically in a power outage eliminating the need for manual override activation. Manual override may still be activated by using a Vantage override switch without affecting the operation of the VA-RRU relay. Specifications Models VA-RRU-1-120V (Use for any applicable 120V service), VA-RRU-1-277V (Use for any applicable 277 V service) Dimensions 3.75”(L) x 1.75”(W) x 1.25”(H) Color Black Ambient temperature 32-104°F (0-40°C) UL924V Emergency lighting equipment WWW.LEGRAND.US/WATTSTOPPER Wiring Diagram - Main Terminal Board Port 2 RS485-1 Gnd Run 2 Secondary Enclosures Bus 2 Bus 3 Bus 4 T/R+ T/R- Station Bus Class 2 Run 1 T/R- T/RT/R+ Controller Bus T/R+ TX5 Gnd Port 5 RX 5 Gnd RX 2 Port 4 TX 2 RX 2 Gnd TX 2 RS-232 Port 3 Gnd CTS 2 RTS 2 RX 2 TX 2 Gnd CTS 1 RTS 1 +12VDC 250mA TX1 RX 1 ON LINE NEUTRAL RS485-2 Gnd T/R+ T/R- Port 1 OFF Gnd Controller Bus Termination 1s T/R+ T/R- Enclosure Address Override 36V Main Enclosure Terminal Board 10s REGULAR LINE HOT (Unswitched) REGULAR PANEL 20 AMP BREAKER REGULAR LINE NEUTRAL Wiring Diagram - Secondary Terminal Board Secondary Enclosure Terminal Board Enclosure Bus Termination 1 2 3 Override GND T/RB T/R+ Override B T/RB GND A T/R+ Enclosure Select OFF ON 1 2 3 Serial # REGULAR LINE HOT (Unswitched) REGULAR PANEL 20 AMP BREAKER REGULAR LINE NEUTRAL WWW.LEGRAND.US/WATTSTOPPER Wiring Diagram - LVOS-0-10-PWM Station LINE AC Lighting load must be powered via EM power to work in override mode LV POS + LV NEG - REGULAR LINE HOT (Unswitched) REGULAR PANEL 20 AMP BREAKER STATION BUS REGULAR LINE NEUTRAL (To InFusion Controller) 2 10mA MAX CONTACT INPUT 4 1 2 ETHERNET 10/100 OVERRIDE 0-10 3 ON OFF GND GND GND GND 3 4 IR SENS +12V 2 0-10 OUTPUTS PWM 1 1 +12V GND GND GND OUT 4 GND PWM OUTPUTS OUT 3 GND OUT 2 GND OUT 1 GND OUT 4 GND OUT 3 OUT 1 STATION BUS CLASS 2 OUT 2 VA-RRU-1-120V or VA-RRU-1-277V Emergency Shunt Relay RELAY 3 4 1 2 3 GND GND LINE LINE NEUTRAL NEUTRAL LOW VOLTAGE OUTPUT STATION-0-10-PWM-DIN INPUT 120-277VAC 50/60 Hz 2 3 4 4 STATUS RELAY: 120-277 VAC/5A MAX. INCANDESCENT 1 STATION BUS CLASS 2 SERIAL NUMBER LVOS-0-10-PWM-DIN 0-10: 10VDC@100mA MAX PWM: 12VDC@100mA MAX 12 AWG Stranded 120V to 277V From 20 AMP Breaker Breaker feeds can be shared as long as the maximum breaker amperage is not exceeded. See the LVOS-0-10-PWM install sheet Ordering Information Catalog # Description Voltage VA-RRU-1-120 Emergency Lighting Shunt Relay 120VAC VA-RRU-1-277 Emergency Lighting Shunt Relay 277VAC WWW.LEGRAND.US/WATTSTOPPER Pub. No. 46101 Rev. 5/2016