Document

advertisement
P Category PATHWAY Lighting Spacing Chart
AS/NZS 1158.3.1:2005
Project Number/Name:
RFL Sample Spacing Charts
Project Number:
10/11/2014
Date:
Revision:
-
Luminaire Description:
RFL530 S70.BEAM 24 LED 48W/700mA 4000K IP66 ALU LEC
111-0347
Stores Code:
Initial Lamp/LED Fixture Flux: 4939
LED - Light Emitting Diode
Light Source:
08
0.8
M i t
Maintenance
FFactor:
t
Lighting Category:
P1 (Pathways - Tables 2.2 & 2.6)
Upcast Angle:
Arrangement:
Offset Distance:
Upward Waste Light Ratio:
Calculation Grid:
Spacings:
0 degrees
Single Side
-1 m
0%
Dependant on Path width (refer Figure 3.8 of
AS/NZS 1158.2)
Mountin
ing Height
Maximum Spacing for Different Path Widths
4
5
6
1
13.7
17.5
20 7
20.7
2
14
17.7
20 9
20.9
3
13.9
17.6
20 8
20.8
4
14
17.7
20 9
20.9
5
6
7
8
9
13.9 12.6
17.7 17.7 16.6 14.2
20 8 20.9
20.8
20 9 20.8
20 8 20
20.77 17
17.88
10
-
7
23.3
23.5
23.4
23.5
23.4 23.5 23.4 23.5 23.5 20.9
8
25.5
25.7
25.6
25.7
25.6 25.7 25.6 25.7 25.7 25.7
Values of light technical parameters and permissible luminaire types for roads in local areas and for pathways
Light technical parameters
Lighting
subcategory
Average horizontal
illuminance (Ēh)
lux
Point horizontal
illuminance (Eph)
lux
Illuminance (horizontal)
uniformity
Cat. P (UE2)
Point vertical
illuminance (Epv)
lux
P1
7
2
10
2
Permisible luminaire type
(see Table 2.10)
Type 4 where part of a road
reserve
TABLE 2.6 AS/NZS 1158.3.1:2005
WE-EF does not accept responsibility for the correctness or compatibility of data prepared other than by its authorised staff. WE-EF © Reproduction, in part or full, is permitted only in connection with activities involving WE-EF products. WE-EF is entitled to withdraw rights from
parties it deems unfit due to improper application. Maximum spacings are in meters generated from Perfect Lite P Category Lighting V 3.07.
Download