P Category PATHWAY Lighting Spacing Chart AS/NZS 1158.3.1:2005 Project Number/Name: RFL Sample Spacing Charts Project Number: 10/11/2014 Date: Revision: - Luminaire Description: RFL530 S70.BEAM 24 LED 48W/700mA 4000K IP66 ALU LEC 111-0347 Stores Code: Initial Lamp/LED Fixture Flux: 4939 LED - Light Emitting Diode Light Source: 08 0.8 M i t Maintenance FFactor: t Lighting Category: P1 (Pathways - Tables 2.2 & 2.6) Upcast Angle: Arrangement: Offset Distance: Upward Waste Light Ratio: Calculation Grid: Spacings: 0 degrees Single Side -1 m 0% Dependant on Path width (refer Figure 3.8 of AS/NZS 1158.2) Mountin ing Height Maximum Spacing for Different Path Widths 4 5 6 1 13.7 17.5 20 7 20.7 2 14 17.7 20 9 20.9 3 13.9 17.6 20 8 20.8 4 14 17.7 20 9 20.9 5 6 7 8 9 13.9 12.6 17.7 17.7 16.6 14.2 20 8 20.9 20.8 20 9 20.8 20 8 20 20.77 17 17.88 10 - 7 23.3 23.5 23.4 23.5 23.4 23.5 23.4 23.5 23.5 20.9 8 25.5 25.7 25.6 25.7 25.6 25.7 25.6 25.7 25.7 25.7 Values of light technical parameters and permissible luminaire types for roads in local areas and for pathways Light technical parameters Lighting subcategory Average horizontal illuminance (Ēh) lux Point horizontal illuminance (Eph) lux Illuminance (horizontal) uniformity Cat. P (UE2) Point vertical illuminance (Epv) lux P1 7 2 10 2 Permisible luminaire type (see Table 2.10) Type 4 where part of a road reserve TABLE 2.6 AS/NZS 1158.3.1:2005 WE-EF does not accept responsibility for the correctness or compatibility of data prepared other than by its authorised staff. WE-EF © Reproduction, in part or full, is permitted only in connection with activities involving WE-EF products. WE-EF is entitled to withdraw rights from parties it deems unfit due to improper application. Maximum spacings are in meters generated from Perfect Lite P Category Lighting V 3.07.