HBP Powerstrip Industrials Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • Inexpensive way to get a high-bay lumen package where cost is a large factor and a lens is not required. • Distribution works well in both open high-bay and aisle applications. • Available up to 8 lamp configuration to replace a variety of historical high wattage outdated luminaires. • Fluorescent technology is proven to provide long life. • Excellent lumen maintenance (95% versus ~65% for typical metal halide). • Superior color rendering (82 CRI, versus 65-70 for metal halide). • Made In USA. Meets ARRA & Buy American requirements. Construction • Standard white 22ga steel housing or specification grade 20ga steel housing • Rigid design allows mounting individually or in rows • Multiple reflector options available for high and low-bay mounting and distribution applications • Standard mounting holes and v-hangers included • Additional mounting hardware available • Optional wireguard • Weight: 1x4 - 6 lbs. 1x8 - 13 lbs. • Weight specification grade: 1x4 - 8 lbs. 1x8 - 15 lbs. Certifications • UL 1598 listed for Canada and U.S. • Luminaires bear appropriate listing labels. • Emergency-equipped fixtures labeled UL 924. Electrical • • • • • • • • Application Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Lamp frequency: > 42 kHz Power Factor: >0.9% @ full load, 100V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Current & Short Circuit with self-recovery Compliant to FCC 47CFR Part 18 Non-consumer Class A Sound Rating Optional emergency battery backup Optional step down transformer, drops 480 VAC to 277 VAC • Open fixtures suitable up to 50°C/122°F • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Manufacturing • Task • Warehouses • Assembly • Commercial • Storage • Industrial • High-Bay • Factory • Low-Bay ORDERING INFORMATION – MODEL HBP Powerstrip Industrials – – SIZE – – – – LAMP QTY BALLAST VOLTAGE1 BALLAST STARTING3 2L 2 Lamp UL x Universal IS Instant Start ISD Instant Start (1x4) 1x4 1x4 Nominal 1x8 1x8 Nominal EXAMPLE HBP-1X8-6L-T8-UL2-HP-33IS-ST-WA 3L 3 Lamp (1x4) 120-277 VAC UHx 347-480 4L 4 Lamp VAC 6L 6 Lamp BALLAST FACTOR2 8L 8 Lamp LP Low Power (1x4, 1x8) (1x8) (1x8) LAMP TYPE T5HO T5HO T8 T8 (.75-.78) MP Medium Power (.85-.88) MN Neutral Power (.97-1.04) HP High Power (1.15-1.20) FOOTNOTES 1. Numeral indicates number of ballasts per fixture. 2. "MN" Ballast factor not for use with T8/ISD or T8/PS. 3. When using UL2, identify number of lamps powered by each ballast before starting method. Largest number first. Ex: 42PS = 6LT5HO. 4. Contact factory for additional cord & mounting options. 5. Numeral indicates number of lamps controlled, HBA is std. For Wattstopper, specify -WS after sensor option. Step Dimming PS Programmed Start BALLAST GRADE ST Standard Grade UE Ultra Efficient T8 – – – – REFLECTOR MATERIAL EA Enhanced Aluminum 95% WA White Aluminum Reflector 90-91% MM Micro Matte 91-93% OTHER WG Zinc Wireguard WW White Wireguard HB 2 Point Mount Dedicated Hanging Brackets HBTB Hanging Brackets + Top Mount Box DSTB Dottie Slots + Top Mount Box TRS Step Down Transformer (Takes 480 to 277 VAC) PF Partial/Full Switch CORD PLUG4 C6 C6/ L715 C6/515 6' Cord, No Plug 6' Cord & Plug (L7-15P) 6' Cord & Plug (515P) PQC15 15' Cord/Quick Connect OCC SENSOR5 – OTHER LF Factory Lamps (Lamp spec elsewhere) EB Emergency Battery Backup 1PK Individually Boxed Fixture SHx Standard 360° View High-Bay Sensor RHx Rectangular Aisle View High-Bay Sensor SLx Standard 360° View Low-Bay Sensor RLx Rectangular Aisle View Low-Bay Sensor Page 1/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HBP Powerstrip Industrials PHOTOMETRIC DATA PHOTOMETRIC DATA: HBP-1X4-3L-T5HO-UL1-MN-PS-ST-EA LUMINAIRE DATA INDOOR CANDELA PLOT Luminaire RCR 80 70 111 101 91 83 76 70 65 60 56 52 49 50 111 96 83 73 65 58 52 47 43 40 37 10 111 88 71 59 50 43 38 33 30 27 24 70 108 98 89 81 74 68 63 58 54 51 48 50 108 94 82 72 64 57 51 46 42 39 36 27 44 77 100 2460 60 3690 50 4920 0 10 20 50 30 108 90 75 64 56 49 43 39 35 32 29 %Fixt 25 41 72 93 70 70 30 111 92 77 65 56 49 44 39 35 32 29 %Lamp 3774 6136 10768 13996 80 30 40 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ RC Lumens 0-30 0-40 0-60 0-90 1230 COEFFICIENTS OF UTILIZATION (%) RW 0 1 2 3 4 5 6 7 8 9 10 Zone 10 108 86 70 58 50 43 37 33 29 27 24 50 104 90 78 69 61 55 50 45 41 38 35 30 104 87 73 63 54 48 42 38 34 31 29 0 10 104 84 69 57 49 42 37 33 29 26 24 0 93 77 63 53 45 39 34 30 27 24 22 AVG. LUMINANCE (Candela/Sq. M.) Average Luminance Angle HBP-1X4-3L-T5HO-UL1-MN-PS-ST-EA 1x4 Powerstrip Industrials Ballast 4L54 Ballast Factor 1.00 Lamp F54 Fixture Lumens 13996 Watts 176 Fixture Efficiency 93% Mounting Suspended Shielding Angle 0° = 90 90° = 90 Spacing Criterion 0° = 1.06 90° = 1.06 Luminous Opening Length: 4.00 in feet Width: 1.06 Height: 0.00 ZONAL LUMEN SUMMARY 90 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90 4648 4476 4487 4423 4370 4226 4003 3724 3463 3124 2811 2443 2029 1649 1251 906 584 269 4648 4663 4688 4622 4594 4425 4244 3938 3593 3279 2882 2479 2092 1707 1318 912 598 341 4648 4768 4794 4789 4706 4393 4014 3793 3487 3070 2769 2508 2122 1615 1195 1025 731 438 4648 4893 4799 4839 4584 4184 4092 3646 3352 3100 2947 2423 1924 1493 1408 1157 752 540 4648 4752 4920 4863 4478 4189 4081 3592 3386 3233 2909 2334 1869 1542 1494 1178 757 583 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance MOUNTING OPTIONS - SUSPENDED DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Included Order Separately HB 2-POINT HANGING BRACKETS V-HANGER Optional - Factory Installed Included DOTTIE SLOT WITH V-HANGER GRIPPLE LOOP Order Separately TOP BOX FOR POWER SUPPLY Included Optional 4" OR GRIPPLE LOOP Order Separately 4" 2" Page 2/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HBP Powerstrip Industrials FIXTURE DIMENSIONS T5HO T8 2L-CROSS SECTION, 2L-4' or 4L-8' FIXTURE 2L-CROSS SECTION, 2L-4' or 4L-8' FIXTURE 11.418" 4.310" 8.562" 3.090" 3.375" 2.780" T5HO T8 3L-CROSS SECTION, 3L-4' or 6L-8' FIXTURE 3L-CROSS SECTION, 3L-4' or 6L-8' FIXTURE 12.325" 4.310" 12.325" 4.310" 3.250" 3.250" T5HO T8 4L-CROSS SECTION, 4L-4' or 8L-8' FIXTURE 4L-CROSS SECTION, 4L-4' or 8L-8' FIXTURE 11.639" 4.310" 11.639" 4.310" 2.780" 2.850" *Drawings N.T.S. Page 3/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com HBP Powerstrip Industrials EXISTING VS. PROPOSED HIGH-BAY SYSTEM Existing High-Bay System MH250 MH320PS MH400 HPS400 MH1000 (16k Hours) MH1000 (12k Hours) MH1000 (8k Hours) MH1000 (4k Hours) Proposed High-Bay System Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens 1 1 1 1 1 1 1 1 Std MH250 PS MH320 Std MH400 Std HPS400 MH1000/U MH1000/U MH1000/U MH1000/U 20,500 31,700 38,000 50,000 110,000 110,000 110,000 110,000 58% 62% 58% 70% 26% 37% 50% 72% 11,890 19,654 22,040 35,000 28,600 40,700 55,000 79,200 11,890 19,654 22,040 35,000 28,600 40,700 55,000 79,200 Lamp Quantity & Type Initial Lamp Lumens Lumen Maintenance EOL (1) Lumens All Lamps Total Fixture Lumens FP54T5HO FP54T5HO FP54T5HO 5,000 5,000 5,000 93% 93% 93% 4,650 4,650 4,650 9,300 18,600 27,900 1.00 1.00 1.00 2L-T5HO 4L-T5HO 6L-T5HO 2 4 6 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 0.75 0.75 0.75 0.75 0.75 0.75 0.75 0.75 8,918 14,741 16,530 26,250 21,450 30,525 41,250 59,400 EOL (1) Ballast Fixture Lumens Per Factor Efficiency Fixture S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 1.49 1.49 1.49 0.62 1.49 1.49 1.49 1.49 12,171 20,119 22,561 18,080 29,276 41,662 56,300 81,072 295 368 458 464 1080 1080 1080 1080 S/P (2) Ratio Net (3) EOL Lumens Fixture Input Watts 0.92 0.92 0.92 8,556 17,112 25,668 1.62 1.62 1.62 12,465 24,930 37,395 117 234 351 468 8L-T5HO 8 FP54T5HO 5,000 93% 4,650 37,200 1.00 0.92 34,224 1.62 49,860 2L-T8 Plus 2 F32T8/841 2,950 90% 2,655 5,310 1.15 0.90 5,496 1.62 8,007 73 4L-T8 Plus 4 F32T8/841 2,950 90% 2,655 10,620 1.14 0.90 10,896 1.62 15,874 147 6L-T8 Plus 6 F32T8/841 2,950 90% 2,655 15,930 1.18 0.90 16,918 1.62 24,647 218 8L-T8 Plus 8 F32T8/841 2,950 90% 2,655 21,240 1.14 0.90 21,792 1.62 31,749 294 (1) EOL = End of life (2) S/P Ratio = Scotopic to Photopic Lumens (3) Net EOL Lumens = EOL Lumens Per Fixture x (S/P).78 [.78 exponent] *Lamp/ballast system values shown are a general reference intended to supply a quick comparison of several common lamp/ballast systems, the associated energy consumption, and net lumen output. *Values shown are based on normal operating temperatures (25°C T8 and 35°C T5) and at 277 volts. *Fixture efficiency percentages are generally representative of each system type, actual values will vary. *There are many operating variables that affect system output, in addition to rating variances from brand to brand. *All T8 electronic ballast values shown are based on Ultra Efficient (aka 3rd Generation) T8 ballasts. *All T5 and T8 lamp values shown are for basic grade lamps. Extended life and higher lumen lamp types are available. *In addition to those shown, there are a wide variety of systems to choose from, each with distinct features and cost points. *Please consult the lamp/ballast manufacturer's catalogs for the detailed information required to model your system. Page 4/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com