Daikin Applied (UK) Ltd Air cooled screw condensing unit, standard efficiency, low sound ERAD-E-SL Screw compressor ›› One refrigerant circuit with single screw compressor ›› Compact design ›› Large operation range (ambient temperature down to -18°C) ›› Extensive option list (heat recovery option available) ERAD-E-SL MicroTech III ERAD-E-SL Cooling only Cooling capacity Power input Capacity control EER Dimensions Weight Air heat exchanger Compressor Fan Fan motor Sound power level Sound pressure level Refrigerant Piping connections Unit Power supply Nom. Cooling Nom. Method Minimum capacity Unit Height Width Depth Unit Operation weight Type Type Quantity Type Air flow rate Nom. Quantity Speed Cooling Nom. Cooling Nom. Cooling Nom. Type/GWP Circuits Quantity Evaporator water inlet/outlet (OD) Starting current Max Running current Cooling Nom. Max Phase/Frequency/Voltage ERAD-E-SL kW kW 120 116 42.4 140 137 52.5 160 159 57.7 2.74 2.61 2.75 190 187 66.3 % mm mm mm kg kg l/s 2,165 1,684 1,717 8,373 8,144 2 rpm dBA dBA A A A Hz/V 89 151 73 83 90 100 210 240 209 243 73.9 78.1 Stepless 25.0 2.83 3.11 300 298 91.9 350 352 122 410 409 150 460 462 167 3.24 2.88 2.73 2.76 2,273 2,223 1,292 2,236 3,065 3,965 3,070 1,841 2,036 2,789 1,881 2,081 2,886 High efficiency fin and tube type with integral subcooler Single screw compressor 1 Direct propeller 12,560 12,216 16,747 16,288 25,120 24,432 3 4 6 700 90 91 92 93 71 73 74 R-134a/ 1,430 1 76mm 139.7mm 195 288 330 410 98 112 125 131 155 204 249 275 115 128 151 158 189 234 276 290 3~/50/400 Cooling: evaporating temperature 7°C; ambient air temperature 35°C; unit at full load operation | Its functioning relies on fluorinated greenhouse gases For more information email info@daikinapplied.uk or visit www.daikinapplied.uk London Sales Office 69 Questor Estate Pearsons Way Dartford, Kent DA1 1JN 01322 424950 Head Office Bassington Industrial Estate Cramlington, Northumberland NE23 8AF 01670 566159 Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages (LCP), Air handling units (AHU), Fan coil units (FCU) and variable refrigerant flow systems (VRF) Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V. Printed on non-chlorinated paper.