ERAD-E-SL - Air cooled screw condensing unit, standard efficiency

advertisement
Daikin Applied (UK) Ltd
Air cooled screw
condensing
unit, standard
efficiency, low
sound
ERAD-E-SL
Screw compressor
›› One refrigerant circuit with single
screw compressor
›› Compact design
›› Large operation range (ambient
temperature down to -18°C)
›› Extensive option list (heat recovery
option available)
ERAD-E-SL
MicroTech III
ERAD-E-SL
Cooling only
Cooling capacity
Power input
Capacity control
EER
Dimensions
Weight
Air heat exchanger
Compressor
Fan
Fan motor
Sound power level
Sound pressure level
Refrigerant
Piping connections
Unit
Power supply
Nom.
Cooling
Nom.
Method
Minimum capacity
Unit
Height
Width
Depth
Unit
Operation weight
Type
Type
Quantity
Type
Air flow rate
Nom.
Quantity
Speed
Cooling Nom.
Cooling
Nom.
Cooling
Nom.
Type/GWP
Circuits
Quantity
Evaporator water inlet/outlet (OD)
Starting current Max
Running current Cooling Nom.
Max
Phase/Frequency/Voltage
ERAD-E-SL
kW
kW
120
116
42.4
140
137
52.5
160
159
57.7
2.74
2.61
2.75
190
187
66.3
%
mm
mm
mm
kg
kg
l/s
2,165
1,684
1,717
8,373
8,144
2
rpm
dBA
dBA
A
A
A
Hz/V
89
151
73
83
90
100
210
240
209
243
73.9
78.1
Stepless
25.0
2.83
3.11
300
298
91.9
350
352
122
410
409
150
460
462
167
3.24
2.88
2.73
2.76
2,273
2,223
1,292
2,236
3,065
3,965
3,070
1,841
2,036
2,789
1,881
2,081
2,886
High efficiency fin and tube type with integral subcooler
Single screw compressor
1
Direct propeller
12,560
12,216
16,747
16,288
25,120
24,432
3
4
6
700
90
91
92
93
71
73
74
R-134a/ 1,430
1
76mm
139.7mm
195
288
330
410
98
112
125
131
155
204
249
275
115
128
151
158
189
234
276
290
3~/50/400
Cooling: evaporating temperature 7°C; ambient air temperature 35°C; unit at full load operation | Its functioning relies on fluorinated greenhouse gases
For more information email info@daikinapplied.uk or visit www.daikinapplied.uk
London Sales Office
69 Questor Estate
Pearsons Way
Dartford, Kent
DA1 1JN
01322 424950
Head Office
Bassington Industrial Estate
Cramlington, Northumberland
NE23 8AF
01670 566159
Daikin Europe N.V. participates in the Eurovent Certification programme for Liquid Chilling Packages
(LCP), Air handling units (AHU), Fan coil units (FCU) and variable refrigerant flow systems (VRF) Check
ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or
fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of
this publication. All content is copyrighted by Daikin Europe N.V. Printed on non-chlorinated paper.
Download