Power Quality Solutions Eaton 9390 The industry’s best combination of efficiency, management of THD, power factor and power protection With Eaton 9390, you can enjoy an unmatched combination of power protection features in a single system. The three-phase UPS is the result of comprehensive research and user insight gathered by Eaton to develop the best combination of power performance, battery management, scalable architecture, flexibility, and service. High efficiency reduces overall cost of ownership Product Snapshot Power Rating : 40/60/80/100/120/160 kVA Voltage : 400V Frequency : 50Hz Configuration : Online double conversion The Eaton 9390 features innovations that combine to deliver the industry’s best overall power performance. Built on more than 40 years of UPS design expertise, the Eaton 9390 excels in four key factors: 1. Efficiency – maximum usable output power relative to input power 2. Total Harmonic Distortion (THD) keeping input current distortion within acceptable limits 3. Power factor – managing phase shifts between voltage applied and current drawn by circuits 4. Double-conversion topology – co plete isolation of protected loads from input utility power The efficiency rating of a UPS is a measure of the energy the UPS uses for its own operation and dissipates usually in the form of heat. For example, a UPS that is 90% efficient delivers 90 kW of useful output power for every 100 kW it takes in. The more efficient the UPS, the less you pay torun your protected equipment and to cool the UPS. With an advanced design and sophisticated sensing and control circuitry, the Eaton 9390 UPS delivers an efficiency of up to 94%. In addition to dramatic cost savings, this level of system efficiency extends battery runtimes and produces cooler operating conditions within the UPS, which extends the life of components and increases overall reliability and performance. Low THD enhances compatibility with generators The Eaton 9390 uses a new input circuit that is uniquely capable of keeping Total Harmonic Distortion (THD) at a low level – less than 3 percent – without compromising efficiency. A key benefit is that the UPS is therefore compatible with a wide range of generators, even though generator output frequencies will fluctuate when the UPS transitions to generator power and as other loads are started up. Power factor performance maximises compatibility and meets high power factor load requirements The closer the power factor is to unity, the more efficient the transfer of power between source and load. With an input power factor of 0.99, the Eaton 9390 UPS is exceptionally compatible with diverse power sources, especially auxiliary generators. On the output side, the 9390 can also provide its full power capability to loads that have a wide range of leading and lagging power factors, spanning all known computer loads. Double-conversion topology provides the best protection possible With the Eaton 9390’s doubleconversion process, your sensitive electronic systems are completely isolated from raw utility power and all its irregularities. Double conversion provides the highest level of protection available and enables equipments to perform to manufacturer specifications. Whether you are selecting a UPS for a branch office or a large data centre, there is an Eaton 9390 model that delivers just the right combination of performance and price for your needs. Visit our website www.powerquality.eaton.com for more information. Eaton 9390 UPS 40-160 kVA TECHNICAL SPECIFICATIONS <3% (100% linear load); <5% (reference non linear load) 0.9 (e.g. 72 kW at 80 kVA) Output UTHD UPS output power rating (0.9 p.f.) kVA 40 60 80 100 120 160 Output power factor kW 36 54 72 90 108 144 Permitted load power factor 0.7 lagging - 0.8 leading 10 min 100-110%; 30 sec 110-125%; Overload on inverter 10 sec 125-150%; 300 ms >150% Continuous 100-110%, 10 min 110-150%, 5 ms Overload when bypass 1000% Note! Bypass fuses may limit the overavailable load capability General Efficiency in double conversion mode (full load) Efficiency in double conversion mode (half load) Efficiency in Energy Saver System (ESS) Distributed parallelling with Hot Sync technology Field upgradeable 94% 92.5% Battery up to 99% 6+1 yes Inverter/rectifier topology transformer-free IGBT with PWM Audible noise <65 dB / <70 dB Altitude (max) 1000 m without derating (max 2000 m) Input 3 ph + N + PE Nominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz Input frequency range Low -20% at 100% load/-50% at 50% load without battery discharge; High +10%/max +20% 45-65 Hz Input power factor 0.99 Input ITHD less than 4.5% Soft start capability Yes Internal backfeed protection Yes ABM technology or Float Temperature compensation Battery nominal voltage (lead-acid) Charging current / Model Default A Max* A Optional 480 V (40 x 12 V, 240 cells) 40 60 80 100 120 160 10 20­ 20 30 30 40 20 40 40 60 60 80 Accessories External battery cabinets with long-life batteries, X-Slot connectivity (Web/ SNMP, ModBus/Jbus, Relay, Hot Sync, ViewUPS-X remote display), Hot Sync parallel tie cabinet, integrated manual bypass up to 80 kVA, external maintenance bypass switch Communications X-Slot 4 communication bays Serial ports 1 available Relay inputs/outputs 6/3 programmable Compliance with standards Output Output wiring Nominal voltage rating (configurable) Maintenance free VRLA batteries, NiCd Charging method *May be limited by maximum UPS input current rating Input wiring Input voltage range Type 3 ph + N + PE 220/380, 230/400, 240/415 V 50/60 Hz Safety (CB certified) IEC 62040-1, IEC 60950-1 EMC IEC 62040-2 Performance IEC 62040-3 Standard UPS Part number 1028510 1028511 1028512 1028513 1028514 1028515 1028516 Description 9390-40-N-4xO 9390-60-U-4xO 9390-80-N-4xO 9390-100-U-4xO 9390-120-N-4xO 9390-120-U-4xO 9390-160-N-4xO Rating 40 kVA / 36 kW 60 kVA / 54 kW 80 kVA / 72 kW 100 kVA / 90 kW 120 kVA / 108 kW 120 kVA / 108 kW 160 kVA / 144 kW Dimensions (HxWxD) 1879x519x808 mm 1879x519x808 mm 1879x519x804 mm 1879x944x804 mm 1879x944x804 mm 1879x944x804 mm 1879x944x804 mm Headquarters Offices Across India Eaton’s Electrical Sector Americas Region 8609 Six Forks Road Raleigh, NC 27615 U.S.A Mumbai Bangalore EL Floor, VITS Luxury Business Hotel, Andheri Kurla Road, Andheri (East), Mumbai - 400 059 Tel : +91-22-4005 3817 Fax: +91-22-4005 3810 Unit No. 501, 4th Floor, Prestige Atrium, Central Street, Bangalore - 560 001 Tel : +91 80 4901 2200 Fax: +91 80 4901 2239 Chennai No. 22, Chamier’s Road, Block “D” Ashika Chambers, Teynampet, Chennai - 600 018 Tel : +91 44 2432 0249-50 Fax: +91 44 2432 0249 Ahmedabad: Chandigarh: Coimbatore: Cochin: Gurgaon: South Asia Office Eaton’s Electrical Sector Eaton Power Quality Pvt. Ltd. 6th Floor, Tower- B, Plot No. 8, Sector - 127, Noida - 201301 Tel: +91 - 0120 - 3855300 Sales and Service Toll Free Hotline.: 1800 200 7887 E-mail: EatonPowerQualityIndia@eaton.com In the interests of continuous product improvement all specifications are subject to change without notice. www.eaton.com/powerquality Weight 257 kg 313 kg 313 kg 430 kg 430 kg 530 kg 530 kg Sales and Service Operations Hyderabad: Kolkata: Pune: +91 932 703 1597 +91 172 501 1578 +91 934 541 9578 +91 934 982 1582 +91 124 410 0047 +91 124 436 6315 +91 40 4018 9601 +91 33 4004 0968 +91 20 3061 1886 Sri Lanka: +94 112871000 +94 117520031 Nepal: +97 714429777 +97 714429888 +97 714423376 Bangladesh: © 2013 Eaton Corporation, All Rights Reserved, 00DATA1018147 rev E, May 2013