Chubb Fire Chubb Controlmaster 1000 Range Fire Systems Prevent Fire | Detect Fire | Contain Fire | Escape Fire Product Controlmaster 1000 Analogue Addressable Fire Alarm Control Panels System Benefits The New Chubb Controlmaster 1000 Range has some of the most exciting and advanced features found on a fire detection system today Designed Today for all of Tomorrow’s Systems The Controlmaster 1000 Range has been specifically designed by our R&D Department to meet the rigorous demands of a fast moving and technically challenging new world. From a single stand alone panel to the largest site imaginable, Controlmaster 1000 sees off the competition by offering a cost effective solution to today’s complex applications. Versatile and Powerful Controlmaster 1000 has at its heart, a superior processor arrangement that not only enables highly detailed Cause and Effects to be completed simply and easily, but actually lets the installer see at a glance the loading on the Loop, the PSU Calculation. For critical outputs like Plant Shutdown, status monitoring can be displayed at the panel once the activation has occurred, together with indication of output isolation, fault and test facilities. Detectors fitted in the same area or room, may be grouped together so that a single Remote LED output will operate for any detector in the group, sensing a fire condition. Networking Control panels, repeater panels, graphical user interfaces and other network peripherals can all be connected together. In extreme terms, Controlmaster 1000 will span from one Loop to sixty-two Loops, on one Panel, with multiple panel expansion. Remote Terminals (Repeaters) Three types of Remote display terminals are available. The first is an RS Repeater, which is connected directly to any Control Panel on the System and displays only the information relating to ‘its’ panel. Second is a LON Repeater, which displays configurable information, can be connected anywhere on the Network. This version can be set to show information which is most useful to particular staff. Third is the Controlmaster 1000R. Connected onto a Network, it will provide all of the indication and functional controls of any other www.chubb.co.uk panel connected to the same network. CM1000 runs a dynamic simulation of the cause and effects to prove that the various sound patterns and shutdowns will operate correctly once the system has been handed over. Wide Area Networks and Remote Diagnostics With each Controlmaster Network able to accommodate an individual IP Address there are now no limitations to size and scope of System. This means that no matter how big your business is (even Global) our Fire Systems can keep pace with it. Remote diagnostics across the Internet and Condition Based Monitoring are a reality with Controlmaster. Displaying the Facts A significant new feature of the Controlmaster Networking capability is in the ability to display current information, Graphics and even integrated CCTV pictures, to the user at key operational points. Touch Sensitive Screens relay and display easily configurable visual information in order that strategic decisions can be taken in the event of an emergency situation. Optional 24 Hour Monitoring Controlmaster 1000 can be connected to a Chubb Alarm Receiving Centre (ARC). This will provide 24 hour remote monitoring ensuring a rapid response to fire or fault conditions. Designed to exceed the latest European Standards Our Designers set out to meet the rigorous European Standards EN54 Part 2 & 4 Controlmaster 1000 and tested by the world famous LPCB/BRE establishment to ensure compliance. Of course the Controlmaster 1000 Range is capable of achieving so much more and your next project is a good opportunity to see how Chubb can easily fulfil your needs. Chubb Fire Chubb Controlmaster 1000 Range Networking–Lan False Alarm & Investigation Loops: -Up to 8 / panel -Loop powered sounders -500 mA available Lon bus Network: -Fail-safe -Shared info on repeaters and remote terminals Detection zone Remote terminal: Adds control points to the system RS.Rep range T4 or RESET Lon.Rep range Evacuate signal Staff alarm signal T1 LonWorks bus Remote cabinets: Distributed processing Extends reach and loop capacity of panel RS.Rep range Vision.com: -Client/server -Touch-screen & small footprint Vision.Com Vision.Com+ Vision.com+: -Client/server -High-end graphics package T3 Alert signal Staff alarm signal is configurable to operate for a duration T1 (from 10 s up to 10 minutes or infinite), expandable to a delay T2 (from 10 s up to 10 minutes or infinite). The period sould be agreed with all relevant authorities, but should be suffisant to enable staff to investigate the initial alarm signal (BS 5839-1). T2 Evacuation Alarm Zone no 1 Single phase alarm Networking–Wan Staged alarm Alarm Zone no 2 Vision.Com Software Master Alarm Zone no 3 Phased alarm Alarm Zone no 1 Alarm Zone no 2 Alarm Zone no 3 www.chubb.co.uk Chubb Fire Chubb Controlmaster 1000 Range Technical Data Addresses Detection Zones Loops Type of addresses on loops Evacuation Zones Fire protection zones RS Repeaters Lon Repeaters Remote panel Controlmaster 1000R Power Input Voltage (VAC) System Voltage (VDC) Max. Internal Battery Size Current Consumption Panel Quiescent (without additional equipment and detectors) Integrated Outputs Integrated printer output Integrated RS output Integrated relay Integrated outputs for sounders Controlmaster 1010 Controlmaster 1020 Controlmaster 1000M 128 256 1024 32 64 240 1 2 2 - 62 Detectors, call points, sounders, strobes, sounders / strobes, alarm inputs, system inputs 9 33 65 16 64 128 16 16 16 16 64 120 8 32 64 1010 1020 230 +10% & -15% / 50Hz 24 Volts 12 Volt, 17 Ah (x2) 1010 1020 200 mA 1000M 12 Volt, 24 Ah (x2) 1000M 200 mA 1010 1000M Serial output / 9600 Bauds, / 8 bits without parity For up to 16 RS repeaters and / or RS repeater LCD display General fire (1 C/NO/NC – 1A – 48V) and general fault (1 C/NO/NC – 1A – 48V) 2 (1A max for both) Additional Outputs Ancillary relays (programmable) (1 C/NO/NC – 2A – 48V) 128 256 512 Sounders modules + devices on addressable loops 64 256 512 Operation Operators Text for zone description Text for instruction in case of zone in fire Text for address description multiple codes + key option 25 characters fully configurable 25 characters fully configurable 25 characters fully configurable Environment Temperature Range Humidity Range IP Rating 1010 Physical 1010 Dimensions (mm) Weight [Excluding batteries] Colour [Semi gloss light grey] Approvals Part Numbers Control Panel 12V Sealed Lead Acid Battery A4 Framed Operating Instructions 1020 -5°C to +40°C 93% Relative Humidity IP30 1020 355H x 492W x 120D 8Kg 13 Kg Grey colour reference F2SM BS EN54-2:1998 & BS EN54-4:1998 1000M 1000M 533H x 492W x 175D 13Kg 1010 No LED model : F850738N 1020 No LED model :F850741N 1000M CAB S No LED model :F850745N RS Repeater External : 15 - 30 Volts DC 8 mA 170H x 100W x 50D 240 g F850771N F 850772N (LCD display model) LON Repeater External : 15 - 30 Volts DC 33 mA 132H x 216W x 47D 1 Kg Controlmaster 1000R Integrated 40W 180 mA 355H x 492W x 120D 8Kg F850773N Small cabinet F850748N Controlmaster 1000 Repeater Details Power supply Current Consumption Dimensions (mm) Weight Part Numbers Chubb Fire, helping you to: Prevent Fire | Detect Fire | Contain Fire | Escape Fire Call 0800 32 1666 or visit www.chubb.co.uk FPS155/08/06 www.chubb.co.uk