A ARCHITECTURE PLANNING INTERIORS 3194D Airport Loop Costa Mesa California 92626 3405 MEMORANDUM Date: 6.18.2015 To: Ms. Mary Opel, P.E. Construction Manager Facilities Planning South Orange County Community College District 949.348.6021 949'364.1731 From: Seung Paek, AIA Re: IRVINE VALLEY COLLEGE MISC. MODIFICATION t 714.427.0277 f 714.427.0288 WWW.dDARCHITECTURE.CO M SOCCCD 21504.00 FILE CODE Here are item list that describe scope of misc modification: • • • • • • • • • • Item 0: 1st and 2nd floor plans with overall scope. Item 0, SKA'01 and SKA'02 Item 1: Provide top diffusers for light fixtures at lobby. See Item 1, SKA'01 and SKA'02. Item 2: Provide video conference system at room 103 meeting room. Item 2, SKA'01. For electrical see Item 7 Sheet E'1. Item 3: Add opaque tint on glazing to screen interior equipment. Opaque to match adjacent opaque glass. See Item 3, SKA'01. Item 4: Modify ceiling light fixture at room 114 prep.room and 223 prep. room. See SKA'01, SKA'02, SKA'03 and Sheet E'2. Item 5: Replace entire ceiling tile with Amstrong 1811 Fine Fissured High Acoustic to match Classroom at Room 112. See Item 5, SKA'01 Item 6: Remove Ipe wood and cut bent plate at indicated area. Prepare to receive metal screen and paint. Paint to match existing. See SKA'01, SKA'02, SKA'03 and SKA'04. Item 7: Add two(2) big ass fans inside of greenhouse to improve cross ventilation and controls. Add low'E film inside of entire south glazing. See SKA'01, SKA'02, SKA'03, SKA'04, SKA'05, SKA'06 and Sheet E'1. Item 8: Modify connections for systems furniture at offices to create permanent installation. At room 202, connect all pig tails to building outlets. Provide even amount of data and outlets at each system furniture built in partition. For offices, provide wire managements Neat Tech from Humanscale. See SKA'01 and SKA'02. Item 9: Provide fire escape sleigh near Stair No. 10. See Item 10, SKA'01 and SKA'02. Provide and install metal backing in the studs. Patch and paint any damaged gyp. board. Y:\2015 Projects\21504.00 SOCCD IVC Life Sciences Building, Misc. Projects\Data\C_CD\C4 Consultant Coordination\Memo.docx Item 0 SKA-01 Item 1: Modify two light fixtures to provide lighting diffuser. Item: 2 Accomodate video conference system. Item 3: Add tint on glazing to screen interior equipment. Item 4: Modify lighting layout on ceiling.. Item 5: Alter ceiling tile. To match classroom. Item 7: Modify greenhouse to improve cross ventilation and controls. Add low-E film inside of entire south glazing. Item 6: Ipe wood modification. Item 0 SKA-02 Item 10: Fire escape sleigh Item 8: Modify connections for systems furniture at offices to create permanent installation. Provide wire management to all office desk. Item 9: Modify lighting layout on ceiling.. Item 1 SKA-02 (6) fixtures to be covered with diffuser. 8 7 6 4 5 PROPRIETARY. THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF FINELITE, INC. ANY REPRODUCTION, DISTRIBUTION, DISPLAY, OR PREPARATION OF DERIVATIVE WORKS IN PART OR WHOLE WITHOUT THE EXPESSED WRITTEN PERMISSION OF FINELITE, INC. IS PROHIBITED. 3 ECO -- 2 1 REVISIONS REV. P01 DESCRIPTION INITIAL RELEASE DATE 07/11/13 APPROVED CHECKED D.AZIZ Item 1 SKA-01 D D 47.500 C C 4.445 FIELD VERIFY ALL DIMENSION. B B NOTES: UNLESS OTHERWISE SPECIFIED: MATERIAL IS ACRYLIC, UV STABLE, UL 94HB MIN, IMPACT RESISTANT, .080 THICK .005, 50% CLEAR FROST - BOTH SIDES, 90% 2% LIGHT TRANSMISSION. UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES A TOLERANCES: x.xx x.xxx .02" .010" ANGLES = 1 MATERIAL NEXT ASSY USED ON FINISH 7 6 5 4 3 APPROVALS DRAWN 30500 WHIPPLE RD. UNION CITY, CA 94587 TEL 510.441.1100 FAX 510.441.1510 DATE M.Brewer DUSTCOVER, FROSTED, 4FT, S12WM CHECKED SEE NOTES RELEASE ENG SEE NOTES MFG ENG DO NOT SCALE DRAWING 8 CAD GENERATED DRAWING, DO NOT MANUALLY UPDATE SIZE DWG NO 2 SCALE 1:1 REV 16369 B QA ENG CAD FILE: P01 16369 Dustcover, frosted, 4ft, S12wm 1 SHEET 1 OF 1 A Item 2 SKA-01 RELOCATED MARKER BOARD. EXISTING CONTROL CADENZA REMOVE AND RELOCATE EXISTING MARKER BOARD. PROVIDE HDMI OUTLETS NEAR EXISTING POWER AND DATA OUTLETS TO RECEIVE 2(TWO) MONITORS(OFOI) POWER, DATA, HDMI OUTLETS. CONNECT HDMI TO EXISTING CONTROL CADENZA. NOTES: 1. PATCH AND PAINT DAMAGAED GYP. BOARD. 2. PAINT WALL TO MATCH EXISTING COLOR. 3. OFOI: OWNER FURNISHED OWNER INSTALLED. 4. SEE ITEM 7 SHEET E-1 FOR ELECTRICAL INFORMATION. Item 3 SKA-01 ELEC 106 220 SF 1 106 S2R1 T S2R1 M VACUUM PUMP S6 C S2 107 185 SF T 1 T 105 1 ST3R1 102 S5 TELECOMM S2R1 1 ST3 A10 1 107 ST3 PROVIDE AND INSTALL FROSTED(ETCHED) FILM ON EXTERIOR OF EXISTING GLASSING TO MATCH EXISTING OPAQUE GLASSING TYP. 119 S2 119 81 SF GATHERIN BALCONY ABOVE Item 4 SKA-01 (1st Floor and 2nd Floor) Existing light fixtures. (18) 1x4 typ. @ each floor (4) 2x4 typ. @ each floor New light fixtures. Note: 1. Contractor shall verify and make record of all existing items on floor, wall, and ceiling prior to construction. Coordinate all existing items on ceiling. 2. Contractor is responsible for all damaged existing items and equipments during the construction. 3. Contractor shall repair and protect all existing items and equipments prior to Construction. 4. Contractor is responsible for all wiring and connection and installation of light fixtures. 5. See Item 4 Sheet E-2 for Electrical Information. Item 4 SKA-02 BUY AMERICAN ACT OF 2009 COMPLIANT FINELITE High Performance Recessed (HPR) 2x4 Date Project HPR-A Angled Type HPR-F Flat Comments DESCRIPTION HPR is a highly effective recessed luminaire delivering excellent visual comfort and outstanding performance for offices, schools, healthcare, and retail applications. Advanced optical designs make HPR a powerful solution for low-ceiling applications and eliminate the shadows common to other recessed products. Diffuse (DCO) Slotted (SCO) Round (RCO) 4” 24” T8 T5 / T5HO 1, 2, or 3 1, 2, or 3 CENTER SHIELDING OPTIONS: DIMENSIONS / LIGHT ENGINE: INTEGRATED SENSORS: HPR is available with three different center shielding options: a diffuse center optic, a slotted center optic, and a round center optic. Available in 1, 2, or 3 T8, T5 or T5HO lamps. HPR can be specified with integrated daylight or occupancy sensors. ORDERING GUIDE Sample Number: HPR - F - 2x4 - DCO - 1T8 - 277 - SC - C1 - IS.88 - OBO HPR Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data. Form CTK0054.06/11 Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com © 2010 FINELITE, INC. ALL RIGHTS RESERVED. Finelite Series HPR Luminaire Styles (A-Angled, F-Flat) Size (2x4) Center Optic (DCO-Diffuse, SCO-Slotted, RCO-Round) Light Engine (1, 2 or 3 T8, T5 or T5HO) Voltage (120, 277, 347V) Circuiting (SC-Single Circuit, DC-Dual Circuit, SD-Step Dimming) Mounting (C1-1" T-Bar, C2-9/16" T-Bar, C3-Screw Slot, DW-Drywall Kit, SM-Surface Mount) Ballast (IS-Instant Start, PS-Program Start, BL-Bi-level, DI-Dimming, and specify BF*) Integrated Sensors (OBD-Daylight, OBO-Occupancy, OBB-Both) * Standard 0.88 for T8 lamps, 1.0 for T5 or T5HO. Contact factory for available BF’s Contact factory for Master/Satellite and factory-supplied whip options. BUY AMERICAN ACT OF 2009 COMPLIANT I C – R AT E D FINELITE High Performance Recessed (HPR) 2x4 PHOTOMETRY HPR-A: 1 T8-DCO (2x4) HPR-A: 2 T5-DCO (2x4) Efficiency: 87.6% Peak Candela Value: 990@ 0˚ LSI Report: 25411 550 825 CANDLEPOWER SUMMARY 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0.0 990 988 975 953 922 880 828 765 695 617 535 451 367 287 210 139 77 29 0 22.5 990 988 976 953 922 880 827 764 693 615 533 449 365 284 208 137 75 26 0 45 990 987 974 951 917 874 821 758 687 614 535 453 370 288 207 134 71 23 0 67.5 990 985 971 948 913 869 816 756 692 623 548 467 380 293 210 135 70 20 0 HPR-A: 2 T8-DCO (2x4) Efficiency: 86.9% Peak Candela Value: 1548@ 0˚ LSI Report: 25441 275 Efficiency: 84.8% Peak Candela Value: 1733@ 20˚ LSI Report: 25417 450 900 1350 Flux 95 267 401 474 476 408 286 145 31 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0.0 1548 1545 1522 1485 1434 1367 1288 1195 1093 983 864 740 615 491 369 254 150 61 0 22.5 1548 1544 1525 1492 1446 1387 1314 1227 1130 1022 904 778 646 513 383 262 150 58 0 45 1548 1545 1531 1505 1468 1420 1362 1292 1208 1107 987 852 708 558 409 272 152 52 0 67.5 1548 1546 1536 1517 1488 1454 1410 1352 1276 1177 1053 907 746 581 422 276 148 44 0 90 1548 1537 1531 1515 1492 1462 1424 1372 1300 1201 1074 923 757 589 426 276 145 43 0 950 1425 CANDLEPOWER SUMMARY CANDLEPOWER SUMMARY 90 990 979 966 943 908 864 812 754 693 627 554 473 386 298 213 135 69 20 0 475 Flux 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 149 424 653 805 845 750 542 286 65 0.0 1687 1689 1672 1640 1595 1533 1454 1357 1244 1117 979 832 683 538 398 267 151 58 0 22.5 1687 1693 1682 1659 1623 1570 1499 1408 1297 1167 1023 868 710 555 408 271 150 56 0 45 1687 1697 1700 1694 1677 1644 1586 1502 1392 1256 1099 930 757 586 422 274 148 51 0 67.5 1687 1699 1713 1725 1723 1702 1650 1566 1451 1306 1140 960 773 592 421 268 140 44 0 90 1687 1688 1710 1729 1733 1715 1666 1581 1465 1318 1148 963 773 591 419 266 138 43 0 Flux 164 477 752 927 950 815 569 288 64 — Refer to www.finelite.com for additional photometry and product information. SPECIFICATIONS Slotted Center Optic: Die-formed cold-rolled steel panel with 1/16" x 1/2" rectangular hole pattern. Virgin acrylic overlay. REFLECTORS: Die-formed 20-gauge cold-rolled steel reflectors are finished in 96 LG high reflectance matte white powder coat paint. BALLAST: UL listed Class P. Electronic instant-start ballast <10% THD, 0.88 BF standard for T8 lamps. Electronic program-start ballasts <10% THD, 1.0 BF standard for T5/T5HO lamps. Contact factory for available BF’s. Optional adders: program-start ballasts (standard for T5/T5HO), 347V, emergency battery packs, dimming or bi-level ballasts (controls by others). OPTICAL SYSTEM: Optical system components include side lens panels and a center optic element held in place with a frame constructed from die-formed cold-rolled steel. The side lenses are UV-stabilized and impact-resistant frosted virgin acrylic, 0.080” thick. They are either angled toward the center optic or parallel to the ceiling plane. Available options for the center optic elements: Diffuse Center Optic: UV-stabilized and impact-resistant frosted virgin acrylic. Optional Soft Glow Optic (SGO) available for T8 only. Round Center Optic: Die-formed cold-rolled steel panel with precision-punched 3/32” round hole pattern arranged in staggered formation. Virgin acrylic overlay. LIGHT ENGINE: Available in 1, 2, or 3 T8, T5, or T5HO lamp cross sections. ELECTRICAL: Fixtures and electrical components are ETL listed conforming to UL1598 in the USA, and Canada and ETL listed certified to CAN/CSA C22.2 No. 250.0. In accordance with NEC code 410.73 (G) this luminaire contains an internal ballast disconnect. IC-Rated for all lamping except 3 T5HO. Optional Chicago Plenum available. Contact factory. Daylight Sensor Occupancy Sensor INTEGRATED SENSORS: Refer to Occupancy Sensor and Daylight Sensor tech sheets for more info. MOUNTING: Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners. Consult local code for appropriate tie-wire recommendations. Drywall Kit available. Surface mount version available; refer to separate tech sheet. AIR RETURN: Refer to the 2x4, or 2x2 Air Return tech sheets for more information. FEED: 18-gauge wire standard. FINISH: Housing and door assembly painted with 96 LG high reflectance matte white powder coat paint. Available in matte white only. WIRING: Master / Satellite wiring available. Contact factory for configuration options. Optional whips (with flex connectors) supplied in a max. of 11’ lengths. WEIGHT: Maximum weight: 2x4 - 33 lbs. Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data. Form CTK0054.06/11 Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com © 2010 FINELITE, INC. ALL RIGHTS RESERVED. CONSTRUCTION: Fixture assembly constructed using die-formed 20-gauge cold-rolled steel housing and ends. All components are hard-tooled to tolerances of 0.010". Ballast compartment is accessible from below. Optical system retained using hinged door frame assembly to provide easy access to ballast compartment and for re-lamping from below without the need of tools. Seismic brackets are integrated into the fixture assembly. Additional wire entrances are positioned on the ends of the housing to allow easy wiring access for the installer. Item 4 SKA-03 BUY AMERICAN ACT OF 2009 COMPLIANT High Performance Recessed (HPR-LED) 1x4 try B us 10 st e In d FINELITE Year LED Warranty IC – RATED Date HPR-LED Collection 2011 IES Progress Report Selection Qualified Luminaire Project Type Comments HPR-A (Angled) HPR-F (Flat) HPR-LED uses patent pending technology DESCRIPTION HPR-LED is a highly effective recessed luminaire delivering excellent visual comfort and outstanding performance for offices, schools, healthcare, and retail applications. Advanced optical designs make HPR-LED a powerful solution for low-ceiling applications and eliminate the shadows common to other LED recessed products. HPR-LED RoHS compliant. GLARE-FREE ILLUMINATION: 100% SERVICEABLE FROM BELOW: THERMAL MANAGEMENT: A glare-free experience is attained with midpowered LEDs properly distributed and paired with a precise diffuser to eliminate pixilation. The light engine and driver can be easily changed from below ceiling – and it’s simple to install. Mid-powered LEDs let heat be fully dissipated without the need for additional heat sinks. ORDERING GUIDE Sample Number: HPR - A - 1x4- DCO - LED-SO - 4000K - 277V - SC - C1 - OBO HPR Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data. Form CTK0060. 03/15 * Surface Mount available © 2015 FINELITE, INC. ALL RIGHTS RESERVED. Finelite Series HPR Luminaire Styles (A-Angled, F-Flat) Size (1x4) Center Optic (DCO-Diffuse, SCO-Slotted, RCO-Round) Light Engine (LED-SO) LED Color Temperature (3000K, 3500K, 4000K) Driver (120V, 277V) Circuiting (SC-Single Circuit) Mounting (C1-1" T-Bar, C2-9/16" T-Bar, C3-Screw Slot, DW-Drywall Kit)* Integrated Sensors (OBD-Daylight, OBO-Occupancy, OBB-Both) BUY AMERICAN ACT OF 2009 COMPLIANT FINELITE High Performance Recessed (HPR-LED) 1x4 PHOTOMETRY PHOTOMETRY 4” HPR-LED-SO-F DCO SO (1x4) 88.8 Lumens Per Watt 3311 Lumens/37.3 Watts CRI: 82 R9: 5 CCT: 4000K ITL LM79 Report 74753 4” HPR-LED-SO-F DCO SO (1x4) 84.1 Lumens Per Watt 3152 Lumens/37.5 Watts CRI: 82 R9: 3 CCT: 3500K ITL LM79 Report 74752 12” 12” CANDLEPOWER SUMMARY 329 659 988 1317 — Refer to www.finelite.com for additional photometry and product information. IC – RATED 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0.0 22.5 1316 1310 1287 1250 1199 1135 1057 977 878 780 674 574 474 371 277 192 114 48 0 1316 1310 1288 1253 1206 1147 1073 986 891 788 685 576 475 373 283 193 114 45 0 45 1316 1309 1293 1261 1218 1156 1079 995 889 781 670 567 458 355 259 178 99 32 0 67.5 90 1316 1316 1304 1304 1291 1292 1264 1267 1223 1225 1164 1163 1086 1084 990 988 883 876 769 761 660 644 544 535 438 426 336 327 246 233 162 153 88 83 27 26 0 0 CANDLEPOWER SUMMARY Flux 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 124 315 355 630 531 616 600 945 1260 — Refer to www.finelite.com for additional photometry and product information. 501 352 127 45 0.0 22.5 1258 1254 1229 1195 1145 1083 1010 930 841 742 642 548 450 353 263 182 108 46 0 1258 1253 1231 1198 1153 1095 1024 940 848 750 651 551 449 354 267 183 108 43 0 45 1258 1254 1235 1206 1162 1103 1029 945 847 742 637 537 434 338 246 166 95 29 0 67.5 90 1258 1258 1248 1249 1234 1236 1210 1211 1167 1170 1112 1110 1034 1029 943 940 840 835 732 721 625 609 520 509 416 404 318 309 234 220 154 147 83 76 26 24 0 0 Flux 119 339 507 587 571 477 334 177 42 Consult www.finelite.com for 3000K photometric reports. SPECIFICATIONS CONSTRUCTION: Fixture assembly constructed using die-formed 20-gauge cold-rolled steel housing and ends. All components are hard-tooled to tolerances of 0.010". Ballast compartment is accessed from below. High quality, UV stabilized, weather-strip pile gasket with polypropylene backing. Optical system retained using hinged door frame assembly to provide easy access to ballast compartment and for re-lamping from below without the need of tools. Seismic brackets are integrated into the fixture assembly. Additional wire entrances are positioned on the ends of the housing to allow easy wiring access for the installer. REFLECTORS: Die-formed 20-gauge cold-rolled steel reflectors are finished in 96 LG high reflectance matte white powder coat paint. LIGHT ENGINE: 1x4 HPR-LED (3000K) delivers 2796 lumens at 37W. 1x4 HPR-LED (3500K) delivers 3152 lumens at 37.5W and 1x4 HPR-LED (4000K) delivers 3311 lumens at 37.3W. Light engine is made up of high performance mid-powered LEDs and is designed to distribute heat properly to maximize the life of the LED. LED color temperature: 3000K, 3500K or 4000K. CRI: 86 (3000K), 83 (3500K), 82 (4000K), R9: 30 (3000K), R9: 10 (3500K), 7 (4000K). DRIVER: High performance LED driver. Driver is fully accessible from below the ceiling. *120/277v. Power Factor = 95.3% (3000K), 92.7% (3500K), 93.3% (4000K). Contact factory for Emergency Battery backups. Total harmonic distortion (THD) <20%. Input current: 0.33A @ 120VAC, and 0.16A @ 277VAC. Expected driver lifetime: 170,000 hours. Lutron driver options: Lut3W- 3-wire driver, LutES - EcoSystem driver, Lut2W - 2-wire driver. *Driver can be wired as dimming or non-dimming. Dimming is compatible with 0-10v controls with a range of 100-10%. Available options for the center optic elements: Diffuse Center Optic: UV-stabilized and impact-resistant frosted virgin acrylic. Slotted Center Optic: Die-formed cold-rolled steel panel with 1/16" x 1/2" rectangular hole pattern. Virgin acrylic overlay. ELECTRICAL: 120v or 277v prewired. Optional Chicago Plenum available. Factory choice low profile battery backup available. Bodine BSL722 battery backup also available. Battery backups deliver 1500 lumens. Half of the 1x4 will be illuminated in emergency mode. Occupancy Sensor AIR RETURN: Contact factory for more information FEED: 18-gauge wire standard. FINISH: Housing and door assembly painted with 96 LG high reflectance matte white powder coat paint. Available in matte white only. Optional adder: Antimicrobial paint is available. Contact factory. WEIGHT: Maximum weight: 1x4 - 25 lbs. LABELS: Fixtures and electrical components are ETL listed conforming to UL1598 in the USA, and Canada and ETL listed certified to CAN/CSA C22.2 No. 250.0. In accordance with NEC code 410.73 (G) this luminaire contains an internal driver disconnect. IC-Rated. Damp location. WARRANTY: HPR-LED comes standard with a 10-year, warranty on all components. DLC Qualified: HPR-LED 1x4 with Diffuse Center Optic (DCO) is qualified under the DesignLights™ Consortium program. INTEGRATED SENSORS: Refer to Occupancy Sensor and Daylight Sensor tech sheets for more info. Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data. Form CTK0060. 03/15 Daylight Sensor MOUNTING: Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners. Consult local code for appropriate tie-wire recommendations. Drywall Kit available. Surface mount version available; refer to separate tech sheet. © 2015 FINELITE, INC. ALL RIGHTS RESERVED. OPTICAL SYSTEM: Optical system components include diffuser panels and a center optic element held in place with a frame constructed from die-formed cold-rolled steel. The diffusers are UV-stabilized and impact-resistant frosted virgin acrylic, 0.120” thick. They are either angled toward the center optic or parallel to the ceiling plane. . Round Center Optic: Die-formed cold-rolled steel panel with precision-punched 3/32” round hole pattern arranged in staggered formation. Virgin acrylic overlay. BUY AMERICAN ACT OF 2009 COMPLIANT FINELITE IC – RATED High Performance Recessed (HPR-LED) 1x4 Lumen Output Per Foot 3000K 3500K 4000K SO SO SO Lumens Per Foot 699 788 828 Watts Per Foot 9.4 9.4 9.3 Efficacy 76 84 89 SO - Standard Output © 2015 FINELITE, INC. ALL RIGHTS RESERVED. Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data. Form CTK0060. 03/15 Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com Item 5 SKA-01 Replace entire ceiling tiles with Amstrong 1811 Fine Fissured High Acoustic. Coordinate all ceiling penetrations and lighting. Note: 1. Contractor shall verify and make record of all existing items on floor, wall, and ceiling prior to construction. 2. Coordinate all existing items on ceiling. 3. Contractor is responsible for all damaged existing items and equipments during the construction. 4. Contractor shall repair and protect all existing items and equipments prior to Construction. Item 6 SKA-01 REMOVE (11) IPE WOOD PANELS CUT (34) HORIZONTAL IPE WOOD SUPPORT STEEL PLATE. GRIND AND SMOOTH. PAINT TO MATCH, TYP. Demolition Note: Contractor shall verify and make record of all existing items Contractor is responsible for all damaged existing items and equipments during the construction. Contractor shall repair and protect all existing items and equipments.Contractor is responsible for all wiring and connection and installation of light fixtures. Item 6 SKA-02 A A street side WELD ALL AROUND MESH SCREEN FRAME. FLUSH SECTION A-A PROVIDE WIRE MESH PANEL AND FRAMES TO MATCH ADJACENT ACCESS DOOR AROUND CORNER. CONTINUOUS WELDS ALL ROUND MESH FRAMES TO STRUCTURAL FRAMES. PAINT TO MATCH EXISTING. Item 6 SKA-03 Item 6 SKA-04 Item 9 SKA-01 PROVIDE AND INSTALL EVACU-TRAC CD7 WITH STORAGE TO WALL. REMOVE GYP. BOARD ANDPROVIDE AND INSTALL METAL BACKING. REINSTALL GYP. BOARD AND PAINT TO MATCH EXISTING. Item 9 SKA-02 Specifications for an Emergency Evacuation Chair 1.1 Model Type The emergency evacuation chair shall be a Garaventa Evacu-Trac CD7. 1.2 Descent Speed Control Mechanism The emergency evacuation chair shall be equipped with a hydraulic speed governor that controls the descent speed to a range that is safe for the passenger and the operator. Descent speed may vary slightly based on passenger weight and stair angle. As a standard measurement, on a stair slope of 35 degrees and with a passenger of 220 lbs. (100kg), the speed control mechanism shall limit the descent speed to a maximum of 3.6 ft/sec. This descent speed control mechanism shall limit the maximum speed regardless of the operating environment or strength and size of the operator. 1.3 Rubber Track Design The emergency evacuation chair shall have rubber crawler tracks to grip the stair noses. The tracks shall have lugs or teeth to ensure positive traction with the stair noses. The rubber crawler tracks shall have integrated steel wires that minimize the likelihood of stretching or breakage. 1.4 Carrying Capacity and Stair Angle The emergency evacuation chair shall be able to carry passengers weighing up to 300 lbs (136kg) and capable of stopping on the stairway at full weight capacity. The device should be capable of operating on a stair slope of up to 40 degrees. 1.5 Passenger Size Accommodation The emergency evacuation chair shall be designed to not unduly limit the physical dimensions of passengers that can be carried. The seating sling shall be open on the sides and shall not be designed with bars that surround or restrict the seating area. 1.6 Passenger Restraining Straps The emergency evacuation chair shall be equipped with three (3) safety straps to ensure the passenger will be securely restrained in the chair. The safety straps shall secure the passenger’s legs, mid-section, and chest and arms. 1.7 Parking Brake and Stability on Flat Surfaces When occupied by a passenger, the evacuation chair must be able to remain stable and stationary when left unattended on flat surfaces. The evacuation chair shall include a brake system that will prevent it from rolling when unattended in the parked position. 1.8 Emergency Brake and Stability on Stairs The emergency evacuation chair shall be equipped with a secondary, fail-safe, emergency braking system, in addition to the main speed control system. While a passenger occupies it, the chair must be able to come to a complete stop on the stairway without any special effort being exerted by the operator. The brake must operator in a failsafe manner, activating if the operator was to accidentally let go of the handle. It shall be capable of remaining in the stopped position unattended (if required). The evacuation chair shall be able to go from a speed of 3.6-ft per/sec (1.1 m/sec) to a complete stop within 1 second, without assistance from the operator. Garaventa Evacu-Trac Specifications - Rev B Page 1 1.9 Ease of Transfer The emergency evacuation chair must be designed so that in the majority of instances, one person trained in proper transferring procedures can single-handedly transfer the passenger into it from a wheelchair. The evacuation chair's seating position shall not be higher than 12 inches from the floor to the lowest point of the seat sling. The evacuation chair shall be designed with open-sides (without sidebars) to make the transfer of the passenger easy. 1.10 Usability and Operator Size / Strength Requirements The emergency evacuation chair shall be operable, down stairs and across landings with a passenger in place, by one person who has a smaller physical size than the passenger. Size and strength of the operator shall not be a factor in safe operation of the chair. 1.11 Weight of Evacuation Device The weight of the chair shall not exceed 46 lbs (20.7 kgs). 1.12 Seating Material The seating material shall be composed of fire retardant fabric. 1.13 Storage Cabinet Each evacuation chair shall be supplied with a steel cabinet that will be used to store the evacuation chair when not in use. The storage cabinet shall include labeling identifying the contents. The storage cabinet shall be 45.3 inches (1151 mm) high, 20 inches (508 mm) wide, and 11 inches (279 mm) deep. 1.14 Warranty Product shall be warranted against defects in design and workmanship for a period of one year from the date of delivery and installation in the facility. This specification has been prepared by Garaventa Lift to provide design and operational criteria for emergency evacuation chairs. Please address any questions or comments to: Trevor De Jaray Trac Product Sales Representative Garaventa Lift P.O. Box 1769, Blaine, WA 98231-1769 Toll Free: (866) 824-8314 (within the USA and Canada) Email: productinfo@evacutrac.com Garaventa Evacu-Trac Specifications - Rev B Page 2 Item 7 SKA-01 6'-0" 6 in. (152 mm) 6 in. (152 mm) Without LED Module Without LED Module A 9'-1 5/8" 10'-0" 60 in. (1.5 m) A 60 in. (1.5 m) 6'-0" Item 7 SKA-02 26'-1/2" 6'-0" 2'-6" 15 '-7 1/1 6" 6'-0" Provide and install low E-film Ener Logic 35 on entire South wall. Item 7 SKA-03 Fan location Note: Re-route any existing electrical conduits, pipes and fixtures in order to accommodate Fans and required items. Item 7 SKA-04 Haiku 60 The ceiling fan, reinvented The 60-inch (1.5-m) Haiku® is the first Big Ass Fan® designed specifically for homes and small spaces. Its precision hand balancing and silent operation combine for lasting, perfect performance. Haiku is handcrafted with premium materials, including sustainable Moso bamboo and a durable glass-infused matrix composite. Holding the top ENERGY STAR® ranking for ceiling fans, Haiku's energy efficiency exceeds testing requirements by more than 450%. Sophisticated control options include seven speeds, as well as special settings Features and Benefits • Top-ranked ENERGY STAR fan • Ten unique control settings, including the exclusive Whoosh mode • Variety of mounting options for flat or pitched ceilings 8 feet and taller • Hand balanced for wobble-free operation at all speeds such as Whoosh® mode, a proprietary feature which simulates the • Optional patented LED module variations in natural airflow for a greater cooling effect. • Slender remote control and optional wall control Winner of more than 25 international design and technology awards, • Finish options include caramel bamboo, cocoa bamboo, black matrix composite and white matrix composite finish options Haiku is everything you expect from Big Ass Fans, designed specifically for your home. (877) 244-3267 | BIGASSFANS.COM 10-16-2014 • Available with SenseME™ technology that keeps you comfortable automatically Haiku 60 TECHNICAL SPECIFICATIONS 6 in. (152 mm) 6 in. (152 mm) Without LED Module With LED Module A B 60 in. (1.5 m) 60 in. (1.5 m) Technical Specifications Accessories Model Haiku Matrix Composite Short Mount Model number K3150-SO-XX-XX-03-C Fan diameter 60 in. (1.5 m) Fan height (A) 11.3 in (287.0 mm); drop tube included Fan height (B) 11.8 in. (299.7 mm); drop tube included Hanging weight 16 lb (7.3 kg)* Motor and assembly finishes Black or white Airfoil material Matrix composite Airfoil finishes Black or white Number of airfoils 3 Motor type EC motor with digital inverter drive Number of fan speeds 6 Operating voltage and frequency 100–240 VAC, 1 Φ, 50–60 Hz RPM (min/max) 35/177 RPM Amps (min/max) 0.05/0.363 A Watts (min/max) 2/30 W Remote control Included Wireless wall control Optional Standard Controller Optional Wireless Wall Control Airfoil Finishes Optional LED Module FAN: Whoosh® mode On/off Sleep mode Timer Speed Controller features LIGHT: Light on/off 16 dimmable light settings Operational temperature range 32 to 104°F (0 to 40°C) Environment Indoor or covered outdoor use Fan mode indicator LED display Warranty Limited lifetime** *The actual, precise fan weight will vary based on actual individual component weights and finishing. **Limited lifetime warranty available in the US and Canada; certain exclusions apply. Warranties vary by country. See full warranty for details. An ISO 9001:2008 certified company | ©2014 Delta T Corporation dba Big Ass Solutions. All rights reserved Black White Optional Accessory: Haiku 60 Wall Controller TECHNICAL SPECIFICATIONS 1.5 in. (37.4 mm) 1.7 in. (43.4 mm) 4.2 in. (106.2 mm) 3.3 in. 3.8 in. (83.3 mm) (96.5 mm) 1.8 in. (45.6 mm) Technical Specifications Wall Controller Model Wireless Wall Control Compatible model number K3150-SO S3150-SO K3150-A2 S3150-A2 K3150-X2 S3150-X2 Color White RF frequency 900 Mhz Operating range 20 ft from controller to fan; successive fans must be within 20 ft of each other Multiple fan operation* Control up to four fans with a single controller Nominal input power 100–240V FAN: Whoosh® mode On/off Fan speeds: 6 or 7 (model dependent) Sleep mode Off timer Reverse Wall control features LIGHT: Light on/off 16 dimmable light settings User interface Capacitive touch interface Status indicator White LEDs indicate user-entered values Blue LEDs indicate fan speed and lighting level LEDs turn off after 5 seconds of inactivity Parts included Wireless wall control and mounting screws RF board and antenna retainer Wallplate Not included; Decora® wallplate recommended Dimension Fits standard junction box Warranty 1 year warranty in the US and Canada* *1 year warranty available in the US and Canada; certain exclusions apply. Warranties vary by country. See full warranty for details. An ISO 9001:2008 certified company | ©2014 Delta T Corporation dba the Big Ass Fan Company. All rights reserved Controller Settings LED module with 16 settings provides the perfect level of light for any need. Speed options from gentle heat recirculation to a cooling breeze. The exclusive Whoosh® mode simulates the variations in natural airflow. Sleep mode reduces the fan speed by one increment every hour until the lowest speed is reached. In Timer mode, the fan runs at a set speed until the programmed time period ends. The Clear button returns the fan to default settings. Item 7 SKA-05 Haiku ® SECTION 23 34 00 HVAC Fans PART 1 GENERAL 1.1 SUMMARY A. Section Includes 1. The ceiling-mounted circulation fan is the model scheduled with the capacities indicated. The fan shall be furnished with mounting hardware and a remote control as manufactured by Big Ass Fans. B. Summary of Work 1. Installation of the fan, miscellaneous or structural metal work (if required), field electrical wiring, cable, conduit, fuses and disconnect switches, other than those addressed in the installation scope of work, shall be provided by others. Installation services are available through Big Ass Fans. Consult the appropriate installation scope of work for information on the available installation options, overview of customer and installer responsibilities, and details on installation site requirements. 1.2 RELATED SECTIONS A. 26 00 00 Electrical 1.3 REFERENCES A. B. C. D. E. F. G. H. I. J. Electromagnetic Compatibility (EMC) Federal Communications Commission (FCC) International Electrotechnical Commission (IEC) International Organization for Standardization (ISO) Low Voltage Directive (LVD) National Electric Code (NEC) National Fire Protection Agency (NFPA) Norma Oficial Mexicana (NOM) Restriction of Hazardous Substances (RoHS) Underwriters Laboratory (UL) 1.4 SUBMITTALS A. Shop Drawings: Drawings detailing product dimensions, weight, and attachment methods B. Part 2 Product Data: Specification sheets on the ceiling-mounted fan, specifying electrical and installation requirements, features and benefits, and controller information C. Revit Files: Files provided for architectural design D. Part 2 Product Documentation: The manufacturer shall furnish a copy of all installation, operation, and maintenance instructions for the fan. E. Schedule 1.5 QUALITY ASSURANCE A. Certifications 1. Safety a. The fan assembly, as a system, shall be ETL-certified and built pursuant to the following standards. 1) United States a) CFR, Title 47, Chapter I, Part 15 Subpart B. Radio Frequency Devices – Unintentional Radiators. b) UL 507. Standard for Safety for Electric Fans. 2. Sustainability Certification a. Forest Stewardship Council (FSC) certification b. ENERGY STAR® certification – ENERGY STAR Most Efficient 2015 Big Ass Fans Haiku® Specification HVAC Fans Section 23 34 00 – Page 1 of 4 Haiku ® B. Manufacturer Qualifications 1. The fan and any accessories shall be supplied by Big Ass Fans that has a minimum of ten (10) years of product experience. 2. ISO 9001:2008-certified 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver product in original, undamaged packaging with identification labels intact. The fan shall be new, free from defects, and factory tested. B. The fan and its components must be stored in a safe, dry location until installation. 1.7 WARRANTY A. The manufacturer shall replace any products or components defective in material or workmanship, free of charge to the customer (including transportation charges within the USA, F.O.B. Lexington, KY), pursuant to the complete terms and conditions of the Big Ass Fans Non-Prorated Warranty in accordance to the following schedule: Item Period of Coverage Motor 2 years All other components 1 year Labor to repair the defect will be provided free of charge at the Big Ass Fans service center for defects arising during the Warranty Period. PART 2 PRODUCT 2.1 MANUFACTURER A. Delta T Corporation, dba Big Ass Fans, PO Box 11307, Lexington, Kentucky 40575. Phone (877) 244-3267. Fax (859) 233-0139. Website: www.bigassfans.com. 2.2 BIG ASS FANS’ HAIKU A. Complete Unit 1. Regulatory Requirements: The fan assembly, as a system, shall be ETL-certified and built pursuant to relevant safety standards as described above. 2. Sustainability Characteristics: The fan shall possess the ENERGY STAR Most Efficient 2015 designation. The bamboo fan assembly, as a system, shall be built pursuant to environmental and sustainability standards of the Forest Stewardship Council. 3. Quality: The fan shall display good workmanship in all aspects of its construction. Field balancing of the airfoils shall not be necessary. 4. Colors and materials: Airfoil materials and colors may be selected by architect or owner as described in 2.2.C, “Airfoils.” 5. Optional accessories: A wall-mounted controller . B. Mounting System 1. Low profile a. The low profile model shall be suitable for flat ceilings as low as 8 ft (2.4 m) tall. b. The fan shall be equipped with a mounting plate, rubber bumpers, a mounting bracket, a compact, low-profile motor hub assembly, and mounting hardware. c. The low profile fan shall be available with either a diameter of 52” (1.3 m) or 60” (1.5 m). C. Airfoils 1. The fan shall be equipped with three airfoils spanning a total diameter of either 60″ (1.5 m) or 52” (1.3 m), as specified by the architect or owner. 2. Airfoils shall be available in the following materials. a. Matrix Composite Big Ass Fans Haiku® Specification HVAC Fans Section 23 34 00 – Page 2 of 4 Haiku ® 1) Composite airfoils shall be available in an automotive-grade white finish as specified by the architect or owner. 2) Composite airfoils shall be damp-rated for use in covered outdoor spaces. D. Motor 1. The fan shall have an electronically commutated motor (ECM) rated for 100–240 VAC, single-phase. 2. The motor shall draw 2–30 watts depending on the speed at which the fan is operated and if a light is installed. 3. The fan shall be designed for continuous operation in ambient temperatures of 32 to 104°F (0 to 40°C), and a humidity range of 20–90% (non-condensing). 4. The fan’s motor unit trim (lower cover) shall be available in black or white as specified by the architect or owner. E. Remote Control 1. The fan shall be equipped with a compact remote control that allows intuitive operation of the fan in the following modes: a. Speeds 0 (off) through 7 (high) for standard and extended profile fans; for low profile fans, speeds 0 (off) through 6 (high). b. Sleep mode: Sleep mode shall reduce the fan speed by one increment every hour until the lowest speed is reached. When the programmed time period ends, the fan automatically turns off. Sleep mode is only active when Timer mode is used. c. Timer mode: In Timer mode, the fan runs at a set speed until the programmed time period ends. d. Whoosh® mode: Whoosh mode simulates natural, relaxing breezes by automatically varying the fan speed in a quasi-sinusoidal pattern. 2. The remote included with the (optional) light accessory shall control both the fan and the light. Brightness shall be increased or decreased by pressing the Up or Down Light button on the remote, and the light shall be turned on or off by pressing the Light On/Off button. 3. Each operating mode shall be indicated by a pattern on the fan mode indicator display, which shall be located on the bottom of the fan and shall be visible from the floor. All indicators shall automatically turn off approximately five seconds after the last control button is pressed. 4. The remote shall be 1.2″ wide × 3.4″ tall × 0.2″ thick, and shall operate on a CR 2025 3V lithium battery (included). F. Safety Cable 1. The fan shall be equipped with a safety cable that provides an additional means of securing the fan assembly to the building structure. The safety cable shall be 1.5 mm in diameter and fabricated of aircraft steel. 2. Field construction of safety cables is not permitted. G. Wall Controller 1. The fan shall be equipped with a wireless wall controller in addition to the standard remote control, as specified by the architect or owner. 2. The wall controller shall feature the same controls and functions as the remote control, including fan speed, Sleep mode, Timer mode, and Whoosh mode. 3. The wall controller shall also control the fan light (on/off and variable brightness) if applicable. PART 3 EXECUTION 3.1 PREPARATION A. The fan location must have an appropriate ceiling-mounted outlet box marked, “Acceptable for Fan Support.” If there is not an appropriate outlet box already installed at the location, one must be installed on a ceiling joist or beam and be properly wired. At least 8” (20.3 cm) of wires should be hanging from the outlet box. Additional mounting options may be available. Consult the installation guide for additional details. Big Ass Fans Haiku® Specification HVAC Fans Section 23 34 00 – Page 3 of 4 Haiku ® B. The fan location must be free from obstacles such as lights, cables, or other building components. C. Check the fan location for proper electrical requirements. Consult the installation guide for appropriate circuit requirements. 3.2 INSTALLATION A. Install the fan according to the manufacturer’s installation guide, which includes acceptable mounting methods. B. Minimum Distances 1. Airfoils must be at least 7 ft (2.1 m) above the floor. 2. The airfoils must have at least 2 ft (0.6 m) clearance from all obstructions. C. The fan shall not be located where it will be continuously subjected to wind gusts or in close proximity to the outputs of HVAC systems or radiant heaters. Consult the installation guide for additional details. END OF SECTION Big Ass Fans Haiku® Specification HVAC Fans Section 23 34 00 – Page 4 of 4 EnerLogic | Window Film Benefits for Commercial Use | EnerLogicFilm.com Page 1 of 3 Item 7 SKA-06 EnerLogic for Commercial Use EnerLogic® film delivers year-round comfort and energy cost savings, helping to keep solar heat gain out during summer and radiant heat in during winter. Product Viewer Overview Choose a Film FAQ Case Studies http://www.enerlogicfilm.com/commercial-use/overview 2/10/2015 EnerLogic | Window Film Benefits for Commercial Use | EnerLogicFilm.com Energy Cost Savings in Every Season Like 1 8 1 Page 2 of 3 122 While most commercial window film provides beneficial savings during cooling season, many films have one big drawback: they reduce solar heat gain from windows all year long. In climates where solar heat gain may be desired during the heating season, traditional commercial window film can actually increase the amount of heat required from the HVAC system. Product Viewer Most Efficient Low-E Film Available for Commercial Buildings Like 1 8 1 122 And that’s where EnerLogic® comes in. EnerLogic commercial window film’s low-e coating was developed to offer all the benefits of year-round energy savings while also minimizing iridescent shine. The result is a more aesthetically pleasing, ultra-efficient low-e commercial window film. Why EnerLogic instead of new low-e windows or another low-e window film? New windows may be efficient, but they … • Can cost 3-5 times more than window film • Can take 15-20+ years to provide a return on investment • Generate significant waste during installation Other low-e window films may be less expensive, but they … • Offer significantly less energy savings than EnerLogic film • Can block views to the outdoors at night and on cloudy days • Considerably diminish the amount of natural light entering the building • Appear iridescent http://www.enerlogicfilm.com/commercial-use/overview 2/10/2015 EnerLogic | Window Film Benefits for Commercial Use | EnerLogicFilm.com Typical ROI in 3 Years or Less Like 1 8 1 Page 3 of 3 122 EnerLogic balances the equation by lowering upfront costs and environmental impact without compromising energy efficiency or visibility. It costs a fraction of the price of new windows, and provides up to three times as much heating and cooling savings vs. comparable visible light transmission film. Savings of 5% to 15% in total electricity costs may be expected in commercial facilities. Savings vary based on glass type, window-to-wall ratio, exterior overhangs, climate, the type of window film, and cooling equipment efficiency. Because of the energy savings it affords, facilities managers may expect to see a 100% return on investment with window film in as quickly as three years. Product Viewer Count the Savings. Count the Benefits. Like 1 8 1 122 Of course, EnerLogic also provides all the benefits of traditional window film to facilities of any size in government, healthcare, office, retail, multifamily, hospitality, and education sectors: • Lowers cooling load and costs by reducing solar heat gain • Extend HVAC equipment life by decreasing run time • Reduces use of artificial lighting • Helps eliminate hot/cold spots throughout a space • Reduces glare • Preserves views to the outdoors • Protects against harmful UV rays With these energy savings and ROI, is EnerLogic window film an investment you can afford not to make? http://www.enerlogicfilm.com/commercial-use/overview 2/10/2015 D.2 D BUILDING SECTION Item 8 SKA-01 A8 C.2 C B A.2 A A453 DEAN FACULTY OFFICE OFFICE 1 203 196 SF S2 204 128 SF FACULTY OFFICE 2 FACULTY OFFICE 3 FACULTY OFFICE 4 FACULTY OFFICE 5 205 128 SF 206 128 SF 207 128 SF 208 246 SF S4 S4 S4 8' $ 2" E8 A5 A312 6' $ 3" A453 S3 S4 S4 S4 S4 S4 T T T T S4 1 1 1 203 204 1 1 S2 211 1 1 205 206 1 1 1 212 213 1 TOILET 1 S2R1 FEC 3A 1 PH S19 WORKROOM 1' $ 3" 1 T 1 ST3 215 51 SF S2R1 1 FACULTY OFFICE 7 3A 1 S6 1 2' $ 9 1/8" 211 PH ST4R1 S2R1 5 1 ST3 201 577 SF ST3R1 4 226 3 215 ST3R1 1 S2R1 S4R1 PH 201 S4R1 3A S6 1 DATA A8 ELEV 1 J4 T J8 S2R1 Connect all pig tails to building outlets. Provide and install even amount of data and outlets at each system furniture. For offices, provide and install wire managements, Neat Tech from Humanscale as indicated in Red line. Note: Contractor field verify all location of existing power outlet, data, and desks. A455 T S4R1 210 148 SF 1 FEC E8 A454 ST3 210 MECH 209 137 SF S4 S18 213 111 SF HALLWAY S4R1 FACULTY OFFICE 6 1 209 214 H2 S2R1 1 1 S17 A4 A321 ST3 1 S4R1 1 208 6 F2 XA321A J2 STORAGE S2R1 S4R1 1 207 1 212 192 SF S15 214 60 SF L2 T ST3R1 202 195 SF 202 1 HALLWAY T ADMIN S6 S16 218 79 SF E6 A524 Item 8 SKA-02