Bid 330 Life Sciences Building First Year Discovery

A
ARCHITECTURE
PLANNING
INTERIORS
3194D
Airport Loop
Costa Mesa
California
92626 3405
MEMORANDUM
Date:
6.18.2015
To:
Ms. Mary Opel, P.E.
Construction Manager
Facilities Planning
South Orange County Community College District
949.348.6021
949'364.1731
From:
Seung Paek, AIA
Re:
IRVINE VALLEY COLLEGE MISC. MODIFICATION
t
714.427.0277
f
714.427.0288
WWW.dDARCHITECTURE.CO
M
SOCCCD
21504.00 FILE CODE
Here are item list that describe scope of misc modification:
•
•
•
•
•
•
•
•
•
•
Item 0: 1st and 2nd floor plans with overall scope. Item 0, SKA'01 and SKA'02
Item 1: Provide top diffusers for light fixtures at lobby. See Item 1, SKA'01 and SKA'02.
Item 2: Provide video conference system at room 103 meeting room. Item 2, SKA'01. For
electrical see Item 7 Sheet E'1.
Item 3: Add opaque tint on glazing to screen interior equipment. Opaque to match adjacent
opaque glass. See Item 3, SKA'01.
Item 4: Modify ceiling light fixture at room 114 prep.room and 223 prep. room. See SKA'01,
SKA'02, SKA'03 and Sheet E'2.
Item 5: Replace entire ceiling tile with Amstrong 1811 Fine Fissured High Acoustic to match
Classroom at Room 112. See Item 5, SKA'01
Item 6: Remove Ipe wood and cut bent plate at indicated area. Prepare to receive metal
screen and paint. Paint to match existing. See SKA'01, SKA'02, SKA'03 and SKA'04.
Item 7: Add two(2) big ass fans inside of greenhouse to improve cross ventilation and
controls. Add low'E film inside of entire south glazing. See SKA'01, SKA'02, SKA'03, SKA'04,
SKA'05, SKA'06 and Sheet E'1.
Item 8: Modify connections for systems furniture at offices to create permanent installation. At
room 202, connect all pig tails to building outlets. Provide even amount of data and outlets at
each system furniture built in partition. For offices, provide wire managements Neat Tech from
Humanscale. See SKA'01 and SKA'02.
Item 9: Provide fire escape sleigh near Stair No. 10. See Item 10, SKA'01 and SKA'02.
Provide and install metal backing in the studs. Patch and paint any damaged gyp. board.
Y:\2015 Projects\21504.00 SOCCD IVC Life Sciences Building, Misc. Projects\Data\C_CD\C4 Consultant Coordination\Memo.docx
Item 0 SKA-01
Item 1:
Modify two light
fixtures to provide
lighting diffuser.
Item: 2
Accomodate video
conference
system.
Item 3:
Add tint on
glazing to screen
interior
equipment.
Item 4:
Modify lighting
layout on ceiling..
Item 5:
Alter ceiling tile.
To match
classroom.
Item 7:
Modify greenhouse to improve
cross ventilation and controls.
Add low-E film inside of entire
south glazing.
Item 6:
Ipe wood
modification.
Item 0 SKA-02
Item 10:
Fire escape sleigh
Item 8:
Modify connections for systems furniture at offices to create permanent installation.
Provide wire management to all office desk.
Item 9:
Modify lighting
layout on ceiling..
Item 1 SKA-02
(6) fixtures to
be covered
with diffuser.
8
7
6
4
5
PROPRIETARY. THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY
OF FINELITE, INC. ANY REPRODUCTION, DISTRIBUTION, DISPLAY, OR PREPARATION OF
DERIVATIVE WORKS IN PART OR WHOLE WITHOUT THE EXPESSED WRITTEN PERMISSION OF
FINELITE, INC. IS PROHIBITED.
3
ECO
--
2
1
REVISIONS
REV.
P01
DESCRIPTION
INITIAL RELEASE
DATE
07/11/13
APPROVED CHECKED
D.AZIZ
Item 1 SKA-01
D
D
47.500
C
C
4.445
FIELD VERIFY ALL DIMENSION.
B
B
NOTES: UNLESS OTHERWISE SPECIFIED:
MATERIAL IS ACRYLIC, UV STABLE, UL 94HB MIN, IMPACT RESISTANT,
.080 THICK .005, 50% CLEAR FROST - BOTH SIDES, 90% 2% LIGHT
TRANSMISSION.
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
A
TOLERANCES:
x.xx
x.xxx
.02"
.010"
ANGLES = 1
MATERIAL
NEXT ASSY
USED ON
FINISH
7
6
5
4
3
APPROVALS
DRAWN
30500 WHIPPLE RD.
UNION CITY, CA 94587
TEL 510.441.1100
FAX 510.441.1510
DATE
M.Brewer
DUSTCOVER,
FROSTED, 4FT, S12WM
CHECKED
SEE NOTES
RELEASE ENG
SEE NOTES
MFG ENG
DO NOT SCALE DRAWING
8
CAD GENERATED DRAWING,
DO NOT MANUALLY UPDATE
SIZE DWG NO
2
SCALE 1:1
REV
16369
B
QA ENG
CAD FILE:
P01
16369 Dustcover, frosted, 4ft,
S12wm
1
SHEET 1 OF 1
A
Item 2 SKA-01
RELOCATED MARKER BOARD.
EXISTING
CONTROL
CADENZA
REMOVE AND RELOCATE EXISTING
MARKER BOARD.
PROVIDE HDMI OUTLETS NEAR
EXISTING POWER AND DATA
OUTLETS TO RECEIVE 2(TWO)
MONITORS(OFOI) POWER, DATA,
HDMI OUTLETS. CONNECT HDMI TO
EXISTING CONTROL CADENZA.
NOTES:
1. PATCH AND PAINT DAMAGAED GYP. BOARD.
2. PAINT WALL TO MATCH EXISTING COLOR.
3. OFOI: OWNER FURNISHED OWNER INSTALLED.
4. SEE ITEM 7 SHEET E-1 FOR ELECTRICAL INFORMATION.
Item 3 SKA-01
ELEC
106
220 SF
1
106
S2R1
T
S2R1
M
VACUUM
PUMP
S6
C
S2
107
185 SF
T
1
T
105
1
ST3R1
102
S5
TELECOMM
S2R1
1
ST3
A10
1
107
ST3
PROVIDE AND INSTALL
FROSTED(ETCHED) FILM
ON EXTERIOR OF
EXISTING GLASSING TO
MATCH EXISTING OPAQUE
GLASSING TYP.
119
S2
119
81 SF
GATHERIN
BALCONY
ABOVE
Item 4 SKA-01
(1st Floor and 2nd Floor)
Existing light fixtures.
(18) 1x4 typ. @ each floor
(4) 2x4 typ. @ each floor
New light fixtures.
Note:
1. Contractor shall verify and make record of all existing items on floor, wall, and ceiling prior to construction. Coordinate all existing items on ceiling.
2. Contractor is responsible for all damaged existing items and equipments during the construction.
3. Contractor shall repair and protect all existing items and equipments prior to Construction.
4. Contractor is responsible for all wiring and connection and installation of light fixtures.
5. See Item 4 Sheet E-2 for Electrical Information.
Item 4 SKA-02
BUY AMERICAN ACT OF 2009 COMPLIANT
FINELITE
High Performance Recessed (HPR) 2x4
Date
Project
HPR-A Angled
Type
HPR-F Flat
Comments
DESCRIPTION
HPR is a highly effective recessed luminaire delivering excellent visual comfort and
outstanding performance for offices, schools, healthcare, and retail applications.
Advanced optical designs make HPR a powerful solution for low-ceiling applications
and eliminate the shadows common to other recessed products.
Diffuse (DCO)
Slotted (SCO)
Round (RCO)
4”
24”
T8
T5 / T5HO
1, 2, or 3
1, 2, or 3
CENTER SHIELDING OPTIONS:
DIMENSIONS / LIGHT ENGINE:
INTEGRATED SENSORS:
HPR is available with three different center
shielding options: a diffuse center optic, a
slotted center optic, and a round center optic.
Available in 1, 2, or 3 T8, T5 or T5HO lamps.
HPR can be specified with integrated daylight or
occupancy sensors.
ORDERING GUIDE
Sample Number: HPR - F - 2x4 - DCO - 1T8 - 277 - SC - C1 - IS.88 - OBO
HPR
Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data.
Form CTK0054.06/11
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
© 2010 FINELITE, INC. ALL RIGHTS RESERVED.
Finelite Series HPR
Luminaire Styles (A-Angled, F-Flat)
Size (2x4)
Center Optic (DCO-Diffuse, SCO-Slotted, RCO-Round)
Light Engine (1, 2 or 3 T8, T5 or T5HO)
Voltage (120, 277, 347V)
Circuiting (SC-Single Circuit, DC-Dual Circuit, SD-Step Dimming)
Mounting (C1-1" T-Bar, C2-9/16" T-Bar, C3-Screw Slot, DW-Drywall Kit, SM-Surface Mount)
Ballast (IS-Instant Start, PS-Program Start, BL-Bi-level, DI-Dimming, and specify BF*)
Integrated Sensors (OBD-Daylight, OBO-Occupancy, OBB-Both)
* Standard 0.88 for T8 lamps, 1.0 for T5 or T5HO. Contact factory for available BF’s
Contact factory for Master/Satellite and factory-supplied whip options.
BUY AMERICAN ACT OF 2009 COMPLIANT
I C – R AT E D
FINELITE
High Performance Recessed (HPR) 2x4
PHOTOMETRY
HPR-A: 1 T8-DCO (2x4)
HPR-A: 2 T5-DCO (2x4)
Efficiency: 87.6%
Peak Candela Value: 990@ 0˚
LSI Report: 25411
550
825
CANDLEPOWER SUMMARY
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0.0
990
988
975
953
922
880
828
765
695
617
535
451
367
287
210
139
77
29
0
22.5
990
988
976
953
922
880
827
764
693
615
533
449
365
284
208
137
75
26
0
45
990
987
974
951
917
874
821
758
687
614
535
453
370
288
207
134
71
23
0
67.5
990
985
971
948
913
869
816
756
692
623
548
467
380
293
210
135
70
20
0
HPR-A: 2 T8-DCO (2x4)
Efficiency: 86.9%
Peak Candela Value: 1548@ 0˚
LSI Report: 25441
275
Efficiency: 84.8%
Peak Candela Value: 1733@ 20˚
LSI Report: 25417
450
900
1350
Flux
95
267
401
474
476
408
286
145
31
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0.0
1548
1545
1522
1485
1434
1367
1288
1195
1093
983
864
740
615
491
369
254
150
61
0
22.5
1548
1544
1525
1492
1446
1387
1314
1227
1130
1022
904
778
646
513
383
262
150
58
0
45
1548
1545
1531
1505
1468
1420
1362
1292
1208
1107
987
852
708
558
409
272
152
52
0
67.5
1548
1546
1536
1517
1488
1454
1410
1352
1276
1177
1053
907
746
581
422
276
148
44
0
90
1548
1537
1531
1515
1492
1462
1424
1372
1300
1201
1074
923
757
589
426
276
145
43
0
950
1425
CANDLEPOWER SUMMARY
CANDLEPOWER SUMMARY
90
990
979
966
943
908
864
812
754
693
627
554
473
386
298
213
135
69
20
0
475
Flux
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
149
424
653
805
845
750
542
286
65
0.0
1687
1689
1672
1640
1595
1533
1454
1357
1244
1117
979
832
683
538
398
267
151
58
0
22.5
1687
1693
1682
1659
1623
1570
1499
1408
1297
1167
1023
868
710
555
408
271
150
56
0
45
1687
1697
1700
1694
1677
1644
1586
1502
1392
1256
1099
930
757
586
422
274
148
51
0
67.5
1687
1699
1713
1725
1723
1702
1650
1566
1451
1306
1140
960
773
592
421
268
140
44
0
90
1687
1688
1710
1729
1733
1715
1666
1581
1465
1318
1148
963
773
591
419
266
138
43
0
Flux
164
477
752
927
950
815
569
288
64
— Refer to www.finelite.com for additional photometry and product information.
SPECIFICATIONS
Slotted Center Optic: Die-formed cold-rolled steel panel
with 1/16" x 1/2" rectangular hole pattern. Virgin acrylic
overlay.
REFLECTORS: Die-formed 20-gauge cold-rolled steel
reflectors are finished in 96 LG high reflectance matte white
powder coat paint.
BALLAST: UL listed Class P. Electronic instant-start
ballast <10% THD, 0.88 BF standard for T8 lamps.
Electronic program-start ballasts <10% THD, 1.0 BF
standard for T5/T5HO lamps. Contact factory for available BF’s. Optional adders: program-start ballasts
(standard for T5/T5HO), 347V, emergency battery
packs, dimming or bi-level ballasts (controls by
others).
OPTICAL SYSTEM: Optical system components
include side lens panels and a center optic element
held in place with a frame constructed from die-formed
cold-rolled steel. The side lenses are UV-stabilized and
impact-resistant frosted virgin acrylic, 0.080” thick.
They are either angled toward the center optic or parallel to the ceiling plane.
Available options for the center optic elements:
Diffuse Center Optic: UV-stabilized and impact-resistant frosted virgin acrylic. Optional Soft Glow Optic
(SGO) available for T8 only.
Round Center Optic: Die-formed cold-rolled steel
panel with precision-punched 3/32” round hole
pattern arranged in staggered formation. Virgin acrylic
overlay.
LIGHT ENGINE: Available in 1, 2, or 3 T8, T5, or T5HO
lamp cross sections.
ELECTRICAL: Fixtures and electrical components are
ETL listed conforming to UL1598 in the USA, and Canada
and ETL listed certified to CAN/CSA C22.2 No. 250.0. In
accordance with NEC code 410.73 (G) this luminaire
contains an internal ballast disconnect. IC-Rated for all
lamping except 3 T5HO. Optional Chicago Plenum available. Contact factory.
Daylight
Sensor
Occupancy
Sensor
INTEGRATED SENSORS: Refer to Occupancy
Sensor and Daylight Sensor tech sheets for
more info.
MOUNTING: Standard flange design works with most
lay-in ceiling types. Integral pryout tabs secure luminaire
to ceiling grid from above. Fixture offers tie-in locations
for tie-wire on all corners. Consult local code for appropriate tie-wire recommendations. Drywall Kit available.
Surface mount version available; refer to separate tech
sheet.
AIR RETURN: Refer to the 2x4, or 2x2 Air Return tech
sheets for more information.
FEED: 18-gauge wire standard.
FINISH: Housing and door assembly painted with 96
LG high reflectance matte white powder coat paint.
Available in matte white only.
WIRING: Master / Satellite wiring available. Contact
factory for configuration options. Optional whips (with
flex connectors) supplied in a max. of 11’ lengths.
WEIGHT: Maximum weight: 2x4 - 33 lbs.
Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data.
Form CTK0054.06/11
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
© 2010 FINELITE, INC. ALL RIGHTS RESERVED.
CONSTRUCTION: Fixture assembly constructed using
die-formed 20-gauge cold-rolled steel housing and
ends. All components are hard-tooled to tolerances of
0.010". Ballast compartment is accessible from below.
Optical system retained using hinged door frame
assembly to provide easy access to ballast compartment and for re-lamping from below without the need
of tools. Seismic brackets are integrated into the fixture
assembly. Additional wire entrances are positioned on
the ends of the housing to allow easy wiring access for
the installer.
Item 4 SKA-03
BUY AMERICAN ACT OF 2009 COMPLIANT
High Performance Recessed (HPR-LED) 1x4
try B
us
10
st
e
In
d
FINELITE
Year
LED Warranty
IC – RATED
Date
HPR-LED Collection
2011 IES Progress
Report Selection
Qualified
Luminaire
Project
Type
Comments
HPR-A (Angled)
HPR-F (Flat)
HPR-LED uses patent pending technology
DESCRIPTION
HPR-LED is a highly effective recessed luminaire delivering excellent visual comfort and
outstanding performance for offices, schools, healthcare, and retail applications. Advanced
optical designs make HPR-LED a powerful solution for low-ceiling applications and eliminate
the shadows common to other LED recessed products. HPR-LED RoHS compliant.
GLARE-FREE ILLUMINATION:
100% SERVICEABLE FROM BELOW:
THERMAL MANAGEMENT:
A glare-free experience is attained with midpowered LEDs properly distributed and paired
with a precise diffuser to eliminate pixilation.
The light engine and driver can be easily
changed from below ceiling – and it’s
simple to install.
Mid-powered LEDs let heat be fully dissipated
without the need for additional heat sinks.
ORDERING GUIDE
Sample Number: HPR - A - 1x4- DCO - LED-SO - 4000K - 277V - SC - C1 - OBO
HPR
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data.
Form CTK0060. 03/15
* Surface Mount available
© 2015 FINELITE, INC. ALL RIGHTS RESERVED.
Finelite Series HPR
Luminaire Styles (A-Angled, F-Flat)
Size (1x4)
Center Optic (DCO-Diffuse, SCO-Slotted, RCO-Round)
Light Engine (LED-SO)
LED Color Temperature (3000K, 3500K, 4000K)
Driver (120V, 277V)
Circuiting (SC-Single Circuit)
Mounting (C1-1" T-Bar, C2-9/16" T-Bar, C3-Screw Slot, DW-Drywall Kit)*
Integrated Sensors (OBD-Daylight, OBO-Occupancy, OBB-Both)
BUY AMERICAN ACT OF 2009 COMPLIANT
FINELITE
High Performance Recessed (HPR-LED) 1x4
PHOTOMETRY
PHOTOMETRY
4”
HPR-LED-SO-F DCO SO (1x4)
88.8 Lumens Per Watt
3311 Lumens/37.3 Watts
CRI: 82
R9: 5
CCT: 4000K
ITL LM79 Report 74753
4”
HPR-LED-SO-F DCO SO (1x4)
84.1 Lumens Per Watt
3152 Lumens/37.5 Watts
CRI: 82
R9: 3
CCT: 3500K
ITL LM79 Report 74752
12”
12”
CANDLEPOWER SUMMARY
329
659
988
1317
— Refer to www.finelite.com
for additional photometry and
product information.
IC – RATED
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0.0
22.5
1316
1310
1287
1250
1199
1135
1057
977
878
780
674
574
474
371
277
192
114
48
0
1316
1310
1288
1253
1206
1147
1073
986
891
788
685
576
475
373
283
193
114
45
0
45
1316
1309
1293
1261
1218
1156
1079
995
889
781
670
567
458
355
259
178
99
32
0
67.5
90
1316 1316
1304 1304
1291 1292
1264 1267
1223 1225
1164 1163
1086 1084
990 988
883 876
769 761
660 644
544 535
438 426
336 327
246 233
162 153
88
83
27
26
0
0
CANDLEPOWER SUMMARY
Flux
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
124
315
355
630
531
616
600
945
1260
— Refer to www.finelite.com
for additional photometry and
product information.
501
352
127
45
0.0
22.5
1258
1254
1229
1195
1145
1083
1010
930
841
742
642
548
450
353
263
182
108
46
0
1258
1253
1231
1198
1153
1095
1024
940
848
750
651
551
449
354
267
183
108
43
0
45
1258
1254
1235
1206
1162
1103
1029
945
847
742
637
537
434
338
246
166
95
29
0
67.5
90
1258 1258
1248 1249
1234 1236
1210 1211
1167 1170
1112 1110
1034 1029
943 940
840 835
732 721
625 609
520 509
416 404
318 309
234 220
154 147
83
76
26
24
0
0
Flux
119
339
507
587
571
477
334
177
42
Consult www.finelite.com for 3000K photometric reports.
SPECIFICATIONS
CONSTRUCTION: Fixture assembly constructed using
die-formed 20-gauge cold-rolled steel housing and
ends. All components are hard-tooled to tolerances of
0.010". Ballast compartment is accessed from below.
High quality, UV stabilized, weather-strip pile gasket with
polypropylene backing. Optical system retained using
hinged door frame assembly to provide easy access to
ballast compartment and for re-lamping from below
without the need of tools. Seismic brackets are integrated into the fixture assembly. Additional wire
entrances are positioned on the ends of the housing to
allow easy wiring access for the installer.
REFLECTORS: Die-formed 20-gauge cold-rolled steel
reflectors are finished in 96 LG high reflectance matte
white powder coat paint.
LIGHT ENGINE: 1x4 HPR-LED (3000K) delivers 2796
lumens at 37W. 1x4 HPR-LED (3500K) delivers 3152
lumens at 37.5W and 1x4 HPR-LED (4000K) delivers
3311 lumens at 37.3W. Light engine is made up of high
performance mid-powered LEDs and is designed to
distribute heat properly to maximize the life of the LED.
LED color temperature: 3000K, 3500K or 4000K. CRI:
86 (3000K), 83 (3500K), 82 (4000K), R9: 30 (3000K),
R9: 10 (3500K), 7 (4000K).
DRIVER: High performance LED driver. Driver is fully
accessible from below the ceiling. *120/277v. Power
Factor = 95.3% (3000K), 92.7% (3500K), 93.3% (4000K).
Contact factory for Emergency Battery backups. Total
harmonic distortion (THD) <20%. Input current: 0.33A @
120VAC, and 0.16A @ 277VAC. Expected driver lifetime:
170,000 hours. Lutron driver options: Lut3W- 3-wire driver, LutES - EcoSystem driver, Lut2W - 2-wire driver.
*Driver can be wired as dimming or non-dimming. Dimming
is compatible with 0-10v controls with a range of 100-10%.
Available options for the center optic elements:
Diffuse Center Optic: UV-stabilized and impact-resistant frosted virgin acrylic.
Slotted Center Optic: Die-formed cold-rolled steel
panel with 1/16" x 1/2" rectangular hole pattern. Virgin
acrylic overlay.
ELECTRICAL: 120v or 277v prewired. Optional Chicago
Plenum available. Factory choice low profile battery backup available. Bodine BSL722 battery backup also available.
Battery backups deliver 1500 lumens. Half of the 1x4 will be
illuminated in emergency mode.
Occupancy
Sensor
AIR RETURN: Contact factory for more information
FEED: 18-gauge wire standard.
FINISH: Housing and door assembly painted with 96 LG
high reflectance matte white powder coat paint. Available
in matte white only. Optional adder: Antimicrobial paint is
available. Contact factory.
WEIGHT: Maximum weight: 1x4 - 25 lbs.
LABELS: Fixtures and electrical components are ETL
listed conforming to UL1598 in the USA, and Canada
and ETL listed certified to CAN/CSA C22.2 No. 250.0. In
accordance with NEC code 410.73 (G) this luminaire
contains an internal driver disconnect. IC-Rated. Damp
location.
WARRANTY: HPR-LED comes standard with a 10-year,
warranty on all components.
DLC Qualified: HPR-LED 1x4 with Diffuse Center Optic
(DCO) is qualified under the DesignLights™
Consortium program.
INTEGRATED SENSORS: Refer to Occupancy
Sensor and Daylight Sensor tech sheets for
more info.
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data.
Form CTK0060. 03/15
Daylight
Sensor
MOUNTING: Standard flange design works with most
lay-in ceiling types. Integral pryout tabs secure
luminaire to ceiling grid from above. Fixture offers
tie-in locations for tie-wire on all corners. Consult local
code for appropriate tie-wire recommendations.
Drywall Kit available. Surface mount version available;
refer to separate tech sheet.
© 2015 FINELITE, INC. ALL RIGHTS RESERVED.
OPTICAL SYSTEM: Optical system components
include diffuser panels and a center optic element held
in place with a frame constructed from die-formed
cold-rolled steel. The diffusers are UV-stabilized and
impact-resistant frosted virgin acrylic, 0.120” thick.
They are either angled toward the center optic or parallel to the ceiling plane. .
Round Center Optic: Die-formed cold-rolled steel panel
with precision-punched 3/32” round hole pattern
arranged in staggered formation. Virgin acrylic overlay.
BUY AMERICAN ACT OF 2009 COMPLIANT
FINELITE
IC – RATED
High Performance Recessed (HPR-LED) 1x4
Lumen Output Per Foot
3000K
3500K
4000K
SO
SO
SO
Lumens Per Foot
699
788
828
Watts Per Foot
9.4
9.4
9.3
Efficacy
76
84
89
SO - Standard Output
© 2015 FINELITE, INC. ALL RIGHTS RESERVED.
Due to continuing product improvements, Finelite reserves the right to change specifications without notice. Please visit www.finelite.com for most current data.
Form CTK0060. 03/15
Finelite, Inc. • 30500 Whipple Road • Union City, CA 94587-1530 • 510 / 441-1100 • Fax: 510 / 441-1510 • www.finelite.com
Item 5 SKA-01
Replace entire ceiling tiles with Amstrong 1811
Fine Fissured High Acoustic.
Coordinate all ceiling penetrations and lighting.
Note:
1. Contractor shall verify and make record of all existing items on floor, wall, and ceiling prior to construction.
2. Coordinate all existing items on ceiling.
3. Contractor is responsible for all damaged existing items and equipments during the construction.
4. Contractor shall repair and protect all existing items and equipments prior to Construction.
Item 6 SKA-01
REMOVE (11) IPE WOOD PANELS
CUT (34) HORIZONTAL IPE WOOD
SUPPORT STEEL PLATE. GRIND AND
SMOOTH. PAINT TO MATCH, TYP.
Demolition Note: Contractor shall verify and make record of all existing items Contractor is responsible for all damaged existing items and equipments during the construction.
Contractor shall repair and protect all existing items and equipments.Contractor is responsible for all wiring and connection and installation of light fixtures.
Item 6 SKA-02
A
A
street side
WELD ALL
AROUND MESH
SCREEN FRAME.
FLUSH
SECTION A-A
PROVIDE WIRE MESH PANEL AND FRAMES TO
MATCH ADJACENT ACCESS DOOR AROUND
CORNER. CONTINUOUS WELDS ALL ROUND MESH
FRAMES TO STRUCTURAL FRAMES. PAINT TO
MATCH EXISTING.
Item 6 SKA-03
Item 6 SKA-04
Item 9 SKA-01
PROVIDE AND INSTALL EVACU-TRAC CD7 WITH
STORAGE TO WALL. REMOVE GYP. BOARD
ANDPROVIDE AND INSTALL METAL BACKING.
REINSTALL GYP. BOARD AND PAINT TO MATCH
EXISTING.
Item 9 SKA-02
Specifications for an Emergency Evacuation Chair
1.1 Model Type
The emergency evacuation chair shall be a Garaventa Evacu-Trac CD7.
1.2 Descent Speed Control Mechanism
The emergency evacuation chair shall be equipped with a hydraulic speed governor that
controls the descent speed to a range that is safe for the passenger and the operator.
Descent speed may vary slightly based on passenger weight and stair angle. As a standard
measurement, on a stair slope of 35 degrees and with a passenger of 220 lbs. (100kg), the
speed control mechanism shall limit the descent speed to a maximum of 3.6 ft/sec. This
descent speed control mechanism shall limit the maximum speed regardless of the
operating environment or strength and size of the operator.
1.3 Rubber Track Design
The emergency evacuation chair shall have rubber crawler tracks to grip the stair noses.
The tracks shall have lugs or teeth to ensure positive traction with the stair noses. The
rubber crawler tracks shall have integrated steel wires that minimize the likelihood of
stretching or breakage.
1.4 Carrying Capacity and Stair Angle
The emergency evacuation chair shall be able to carry passengers weighing up to 300 lbs
(136kg) and capable of stopping on the stairway at full weight capacity. The device should
be capable of operating on a stair slope of up to 40 degrees.
1.5 Passenger Size Accommodation
The emergency evacuation chair shall be designed to not unduly limit the physical
dimensions of passengers that can be carried. The seating sling shall be open on the sides
and shall not be designed with bars that surround or restrict the seating area.
1.6 Passenger Restraining Straps
The emergency evacuation chair shall be equipped with three (3) safety straps to ensure
the passenger will be securely restrained in the chair. The safety straps shall secure the
passenger’s legs, mid-section, and chest and arms.
1.7 Parking Brake and Stability on Flat Surfaces
When occupied by a passenger, the evacuation chair must be able to remain stable and
stationary when left unattended on flat surfaces. The evacuation chair shall include a brake
system that will prevent it from rolling when unattended in the parked position.
1.8 Emergency Brake and Stability on Stairs
The emergency evacuation chair shall be equipped with a secondary, fail-safe, emergency
braking system, in addition to the main speed control system. While a passenger occupies
it, the chair must be able to come to a complete stop on the stairway without any special
effort being exerted by the operator. The brake must operator in a failsafe manner,
activating if the operator was to accidentally let go of the handle. It shall be capable of
remaining in the stopped position unattended (if required). The evacuation chair shall be
able to go from a speed of 3.6-ft per/sec (1.1 m/sec) to a complete stop within 1 second,
without assistance from the operator.
Garaventa Evacu-Trac Specifications - Rev B
Page 1
1.9 Ease of Transfer
The emergency evacuation chair must be designed so that in the majority of instances, one
person trained in proper transferring procedures can single-handedly transfer the passenger
into it from a wheelchair. The evacuation chair's seating position shall not be higher than 12
inches from the floor to the lowest point of the seat sling. The evacuation chair shall be
designed with open-sides (without sidebars) to make the transfer of the passenger easy.
1.10 Usability and Operator Size / Strength Requirements
The emergency evacuation chair shall be operable, down stairs and across landings with a
passenger in place, by one person who has a smaller physical size than the passenger. Size
and strength of the operator shall not be a factor in safe operation of the chair.
1.11 Weight of Evacuation Device
The weight of the chair shall not exceed 46 lbs (20.7 kgs).
1.12 Seating Material
The seating material shall be composed of fire retardant fabric.
1.13 Storage Cabinet
Each evacuation chair shall be supplied with a steel cabinet that will be used to store the
evacuation chair when not in use. The storage cabinet shall include labeling identifying the
contents. The storage cabinet shall be 45.3 inches (1151 mm) high, 20 inches (508 mm)
wide, and 11 inches (279 mm) deep.
1.14 Warranty
Product shall be warranted against defects in design and workmanship for a period of one
year from the date of delivery and installation in the facility.
This specification has been prepared by Garaventa Lift to provide design and operational
criteria for emergency evacuation chairs.
Please address any questions or comments to:
Trevor De Jaray
Trac Product Sales Representative
Garaventa Lift
P.O. Box 1769, Blaine, WA 98231-1769
Toll Free: (866) 824-8314 (within the USA and Canada)
Email: productinfo@evacutrac.com
Garaventa Evacu-Trac Specifications - Rev B
Page 2
Item 7 SKA-01
6'-0"
6 in. (152 mm)
6 in. (152 mm)
Without LED Module
Without LED Module
A
9'-1 5/8"
10'-0"
60 in. (1.5 m)
A
60 in. (1.5 m)
6'-0"
Item 7 SKA-02
26'-1/2"
6'-0"
2'-6"
15
'-7
1/1
6"
6'-0"
Provide and install low
E-film Ener Logic 35
on entire South wall.
Item 7 SKA-03
Fan location
Note: Re-route any existing electrical conduits, pipes and fixtures in order to accommodate Fans and required items.
Item 7 SKA-04
Haiku 60
The ceiling fan, reinvented
The 60-inch (1.5-m) Haiku® is the first Big Ass Fan® designed
specifically for homes and small spaces. Its precision hand balancing
and silent operation combine for lasting, perfect performance. Haiku
is handcrafted with premium materials, including sustainable Moso
bamboo and a durable glass-infused matrix composite. Holding the
top ENERGY STAR® ranking for ceiling fans, Haiku's energy efficiency
exceeds testing requirements by more than 450%. Sophisticated
control options include seven speeds, as well as special settings
Features and Benefits
• Top-ranked ENERGY STAR fan
• Ten unique control settings, including the exclusive
Whoosh mode
• Variety of mounting options for flat or pitched ceilings
8 feet and taller
• Hand balanced for wobble-free operation at all speeds
such as Whoosh® mode, a proprietary feature which simulates the
• Optional patented LED module
variations in natural airflow for a greater cooling effect.
• Slender remote control and optional wall control
Winner of more than 25 international design and technology awards,
• Finish options include caramel bamboo, cocoa bamboo, black
matrix composite and white matrix composite finish options
Haiku is everything you expect from Big Ass Fans, designed specifically
for your home.
(877) 244-3267 | BIGASSFANS.COM
10-16-2014
• Available with SenseME™ technology that keeps you
comfortable automatically
Haiku 60
TECHNICAL
SPECIFICATIONS
6 in. (152 mm)
6 in. (152 mm)
Without LED Module
With LED Module
A
B
60 in. (1.5 m)
60 in. (1.5 m)
Technical Specifications
Accessories
Model
Haiku Matrix Composite Short Mount
Model number
K3150-SO-XX-XX-03-C
Fan diameter
60 in. (1.5 m)
Fan height (A)
11.3 in (287.0 mm); drop tube included
Fan height (B)
11.8 in. (299.7 mm); drop tube included
Hanging weight
16 lb (7.3 kg)*
Motor and assembly finishes
Black or white
Airfoil material
Matrix composite
Airfoil finishes
Black or white
Number of airfoils
3
Motor type
EC motor with digital inverter drive
Number of fan speeds
6
Operating voltage and frequency
100–240 VAC, 1 Φ, 50–60 Hz
RPM (min/max)
35/177 RPM
Amps (min/max)
0.05/0.363 A
Watts (min/max)
2/30 W
Remote control
Included
Wireless wall control
Optional
Standard Controller
Optional Wireless Wall Control
Airfoil Finishes
Optional LED Module
FAN:
Whoosh® mode
On/off
Sleep mode
Timer
Speed
Controller features
LIGHT:
Light on/off
16 dimmable light settings
Operational temperature range
32 to 104°F (0 to 40°C)
Environment
Indoor or covered outdoor use
Fan mode indicator
LED display
Warranty
Limited lifetime**
*The actual, precise fan weight will vary based on actual individual component weights and finishing.
**Limited lifetime warranty available in the US and Canada; certain exclusions apply. Warranties vary by country.
See full warranty for details.
An ISO 9001:2008 certified company
|
©2014 Delta T Corporation dba Big Ass Solutions. All rights reserved
Black
White
Optional Accessory:
Haiku 60 Wall Controller
TECHNICAL
SPECIFICATIONS
1.5 in.
(37.4 mm)
1.7 in.
(43.4 mm)
4.2 in.
(106.2 mm)
3.3 in.
3.8 in.
(83.3 mm) (96.5 mm)
1.8 in.
(45.6 mm)
Technical Specifications
Wall Controller
Model
Wireless Wall Control
Compatible model number
K3150-SO
S3150-SO
K3150-A2
S3150-A2
K3150-X2
S3150-X2
Color
White
RF frequency
900 Mhz
Operating range
20 ft from controller to fan; successive fans must be within
20 ft of each other
Multiple fan operation*
Control up to four fans with a single controller
Nominal input power
100–240V
FAN:
Whoosh® mode
On/off
Fan speeds: 6 or 7 (model dependent)
Sleep mode
Off timer
Reverse
Wall control features
LIGHT:
Light on/off
16 dimmable light settings
User interface
Capacitive touch interface
Status indicator
White LEDs indicate user-entered values
Blue LEDs indicate fan speed and lighting level
LEDs turn off after 5 seconds of inactivity
Parts included
Wireless wall control and mounting screws
RF board and antenna retainer
Wallplate
Not included; Decora® wallplate recommended
Dimension
Fits standard junction box
Warranty
1 year warranty in the US and Canada*
*1 year warranty available in the US and Canada; certain exclusions apply. Warranties vary by country. See full warranty for details.
An ISO 9001:2008 certified company
|
©2014 Delta T Corporation dba the Big Ass Fan Company. All rights reserved
Controller Settings
LED module with 16
settings provides the
perfect level of light
for any need.
Speed options
from gentle heat
recirculation to a
cooling breeze.
The exclusive
Whoosh® mode
simulates the
variations in
natural airflow.
Sleep mode reduces
the fan speed by one
increment every hour
until the lowest speed
is reached.
In Timer mode, the
fan runs at a set speed
until the programmed
time period ends.
The Clear button
returns the fan to
default settings.
Item 7 SKA-05
Haiku ®
SECTION 23 34 00
HVAC Fans
PART 1 GENERAL
1.1 SUMMARY
A. Section Includes
1. The ceiling-mounted circulation fan is the model scheduled with the capacities indicated. The fan shall
be furnished with mounting hardware and a remote control as manufactured by Big Ass Fans.
B. Summary of Work
1. Installation of the fan, miscellaneous or structural metal work (if required), field electrical wiring, cable,
conduit, fuses and disconnect switches, other than those addressed in the installation scope of work,
shall be provided by others. Installation services are available through Big Ass Fans. Consult the
appropriate installation scope of work for information on the available installation options, overview of
customer and installer responsibilities, and details on installation site requirements.
1.2 RELATED SECTIONS
A. 26 00 00 Electrical
1.3 REFERENCES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
Electromagnetic Compatibility (EMC)
Federal Communications Commission (FCC)
International Electrotechnical Commission (IEC)
International Organization for Standardization (ISO)
Low Voltage Directive (LVD)
National Electric Code (NEC)
National Fire Protection Agency (NFPA)
Norma Oficial Mexicana (NOM)
Restriction of Hazardous Substances (RoHS)
Underwriters Laboratory (UL)
1.4 SUBMITTALS
A. Shop Drawings: Drawings detailing product dimensions, weight, and attachment methods
B. Part 2 Product Data: Specification sheets on the ceiling-mounted fan, specifying electrical and installation
requirements, features and benefits, and controller information
C. Revit Files: Files provided for architectural design
D. Part 2 Product Documentation: The manufacturer shall furnish a copy of all installation, operation, and
maintenance instructions for the fan.
E. Schedule
1.5 QUALITY ASSURANCE
A. Certifications
1. Safety
a. The fan assembly, as a system, shall be ETL-certified and built pursuant to the following standards.
1) United States
a) CFR, Title 47, Chapter I, Part 15 Subpart B. Radio Frequency Devices – Unintentional
Radiators.
b) UL 507. Standard for Safety for Electric Fans.
2. Sustainability Certification
a. Forest Stewardship Council (FSC) certification
b. ENERGY STAR® certification – ENERGY STAR Most Efficient 2015
Big Ass Fans
Haiku® Specification
HVAC Fans
Section 23 34 00 – Page 1 of 4
Haiku ®
B. Manufacturer Qualifications
1. The fan and any accessories shall be supplied by Big Ass Fans that has a minimum of ten (10) years of
product experience.
2. ISO 9001:2008-certified
1.6 DELIVERY, STORAGE, AND HANDLING
A. Deliver product in original, undamaged packaging with identification labels intact. The fan shall be new,
free from defects, and factory tested.
B. The fan and its components must be stored in a safe, dry location until installation.
1.7 WARRANTY
A. The manufacturer shall replace any products or components defective in material or workmanship, free of
charge to the customer (including transportation charges within the USA, F.O.B. Lexington, KY), pursuant to
the complete terms and conditions of the Big Ass Fans Non-Prorated Warranty in accordance to the
following schedule:
Item
Period of Coverage
Motor
2 years
All other components
1 year
Labor to repair the defect will be provided free of charge at the Big Ass Fans service center for defects arising during the Warranty
Period.
PART 2 PRODUCT
2.1 MANUFACTURER
A. Delta T Corporation, dba Big Ass Fans, PO Box 11307, Lexington, Kentucky 40575.
Phone (877) 244-3267. Fax (859) 233-0139. Website: www.bigassfans.com.
2.2 BIG ASS FANS’ HAIKU
A. Complete Unit
1. Regulatory Requirements: The fan assembly, as a system, shall be ETL-certified and built pursuant to
relevant safety standards as described above.
2. Sustainability Characteristics: The fan shall possess the ENERGY STAR Most Efficient 2015 designation.
The bamboo fan assembly, as a system, shall be built pursuant to environmental and sustainability
standards of the Forest Stewardship Council.
3. Quality: The fan shall display good workmanship in all aspects of its construction. Field balancing of the
airfoils shall not be necessary.
4. Colors and materials: Airfoil materials and colors may be selected by architect or owner as described in
2.2.C, “Airfoils.”
5. Optional accessories: A wall-mounted controller .
B. Mounting System
1. Low profile
a. The low profile model shall be suitable for flat ceilings as low as 8 ft (2.4 m) tall.
b. The fan shall be equipped with a mounting plate, rubber bumpers, a mounting bracket, a compact,
low-profile motor hub assembly, and mounting hardware.
c. The low profile fan shall be available with either a diameter of 52” (1.3 m) or 60” (1.5 m).
C. Airfoils
1. The fan shall be equipped with three airfoils spanning a total diameter of either 60″ (1.5 m) or 52”
(1.3 m), as specified by the architect or owner.
2. Airfoils shall be available in the following materials.
a. Matrix Composite
Big Ass Fans
Haiku® Specification
HVAC Fans
Section 23 34 00 – Page 2 of 4
Haiku ®
1) Composite airfoils shall be available in an automotive-grade white finish as specified by the
architect or owner.
2) Composite airfoils shall be damp-rated for use in covered outdoor spaces.
D. Motor
1. The fan shall have an electronically commutated motor (ECM) rated for 100–240 VAC, single-phase.
2. The motor shall draw 2–30 watts depending on the speed at which the fan is operated and if a light is
installed.
3. The fan shall be designed for continuous operation in ambient temperatures of 32 to 104°F
(0 to 40°C), and a humidity range of 20–90% (non-condensing).
4. The fan’s motor unit trim (lower cover) shall be available in black or white as specified by the architect
or owner.
E. Remote Control
1. The fan shall be equipped with a compact remote control that allows intuitive operation of the fan in
the following modes:
a. Speeds 0 (off) through 7 (high) for standard and extended profile fans; for low profile fans, speeds
0 (off) through 6 (high).
b. Sleep mode: Sleep mode shall reduce the fan speed by one increment every hour until the lowest
speed is reached. When the programmed time period ends, the fan automatically turns off. Sleep
mode is only active when Timer mode is used.
c. Timer mode: In Timer mode, the fan runs at a set speed until the programmed time period ends.
d. Whoosh® mode: Whoosh mode simulates natural, relaxing breezes by automatically varying the
fan speed in a quasi-sinusoidal pattern.
2. The remote included with the (optional) light accessory shall control both the fan and the light.
Brightness shall be increased or decreased by pressing the Up or Down Light button on the remote,
and the light shall be turned on or off by pressing the Light On/Off button.
3. Each operating mode shall be indicated by a pattern on the fan mode indicator display, which shall be
located on the bottom of the fan and shall be visible from the floor. All indicators shall automatically
turn off approximately five seconds after the last control button is pressed.
4. The remote shall be 1.2″ wide × 3.4″ tall × 0.2″ thick, and shall operate on a CR 2025 3V lithium battery
(included).
F. Safety Cable
1. The fan shall be equipped with a safety cable that provides an additional means of securing the fan
assembly to the building structure. The safety cable shall be 1.5 mm in diameter and fabricated of
aircraft steel.
2. Field construction of safety cables is not permitted.
G. Wall Controller
1. The fan shall be equipped with a wireless wall controller in addition to the standard remote control, as
specified by the architect or owner.
2. The wall controller shall feature the same controls and functions as the remote control, including fan
speed, Sleep mode, Timer mode, and Whoosh mode.
3. The wall controller shall also control the fan light (on/off and variable brightness) if applicable.
PART 3 EXECUTION
3.1 PREPARATION
A. The fan location must have an appropriate ceiling-mounted outlet box marked, “Acceptable for Fan
Support.” If there is not an appropriate outlet box already installed at the location, one must be installed
on a ceiling joist or beam and be properly wired. At least 8” (20.3 cm) of wires should be hanging from the
outlet box. Additional mounting options may be available. Consult the installation guide for additional
details.
Big Ass Fans
Haiku® Specification
HVAC Fans
Section 23 34 00 – Page 3 of 4
Haiku ®
B. The fan location must be free from obstacles such as lights, cables, or other building components.
C. Check the fan location for proper electrical requirements. Consult the installation guide for appropriate
circuit requirements.
3.2 INSTALLATION
A. Install the fan according to the manufacturer’s installation guide, which includes acceptable mounting
methods.
B. Minimum Distances
1. Airfoils must be at least 7 ft (2.1 m) above the floor.
2. The airfoils must have at least 2 ft (0.6 m) clearance from all obstructions.
C. The fan shall not be located where it will be continuously subjected to wind gusts or in close proximity to
the outputs of HVAC systems or radiant heaters. Consult the installation guide for additional details.
END OF SECTION
Big Ass Fans
Haiku® Specification
HVAC Fans
Section 23 34 00 – Page 4 of 4
EnerLogic | Window Film Benefits for Commercial Use | EnerLogicFilm.com
Page 1 of 3
Item 7 SKA-06
EnerLogic for Commercial Use
EnerLogic® film delivers year-round comfort and energy cost savings,
helping to keep solar heat gain out during summer and radiant heat in
during winter.
Product
Viewer
Overview
Choose a Film
FAQ
Case Studies
http://www.enerlogicfilm.com/commercial-use/overview
2/10/2015
EnerLogic | Window Film Benefits for Commercial Use | EnerLogicFilm.com
Energy Cost Savings in Every
Season
Like
1
8
1
Page 2 of 3
122
While most commercial window film provides
beneficial savings during cooling season, many
films have one big drawback: they reduce solar heat
gain from windows all year long. In climates where
solar heat gain may be desired during the heating
season, traditional commercial window film can
actually increase the amount of heat required from
the HVAC system.
Product
Viewer
Most Efficient Low-E Film
Available for Commercial
Buildings
Like
1
8
1
122
And that’s where EnerLogic® comes in. EnerLogic
commercial window film’s low-e coating was
developed to offer all the benefits of year-round
energy savings while also minimizing iridescent
shine. The result is a more aesthetically pleasing,
ultra-efficient low-e commercial window film. Why
EnerLogic instead of new low-e windows or another
low-e window film?
New windows may be efficient, but they …
• Can cost 3-5 times more than window film
• Can take 15-20+ years to provide a return on
investment
• Generate significant waste during installation
Other low-e window films may be less expensive,
but they …
• Offer significantly less energy savings than
EnerLogic film
• Can block views to the outdoors at night and on
cloudy days
• Considerably diminish the amount of natural light
entering the building
• Appear iridescent
http://www.enerlogicfilm.com/commercial-use/overview
2/10/2015
EnerLogic | Window Film Benefits for Commercial Use | EnerLogicFilm.com
Typical ROI in 3 Years or Less
Like
1
8
1
Page 3 of 3
122
EnerLogic balances the equation by lowering
upfront costs and environmental impact without
compromising energy efficiency or visibility. It costs
a fraction of the price of new windows, and provides
up to three times as much heating and cooling
savings vs. comparable visible light transmission
film.
Savings of 5% to 15% in total electricity costs may
be expected in commercial facilities. Savings vary
based on glass type, window-to-wall ratio, exterior
overhangs, climate, the type of window film, and
cooling equipment efficiency. Because of the energy
savings it affords, facilities managers may expect to
see a 100% return on investment with window film
in as quickly as three years.
Product
Viewer
Count the Savings. Count the
Benefits.
Like
1
8
1
122
Of course, EnerLogic also provides all the benefits
of traditional window film to facilities of any size in
government, healthcare, office, retail, multifamily,
hospitality, and education sectors:
• Lowers cooling load and costs by reducing solar
heat gain
• Extend HVAC equipment life by decreasing run
time
• Reduces use of artificial lighting
• Helps eliminate hot/cold spots throughout a space
• Reduces glare
• Preserves views to the outdoors
• Protects against harmful UV rays
With these energy savings and ROI, is EnerLogic
window film an investment you can afford not to
make?
http://www.enerlogicfilm.com/commercial-use/overview
2/10/2015
D.2
D
BUILDING
SECTION
Item 8 SKA-01
A8
C.2 C
B
A.2
A
A453
DEAN FACULTY
OFFICE OFFICE 1
203
196 SF
S2
204
128 SF
FACULTY
OFFICE 2
FACULTY
OFFICE 3
FACULTY
OFFICE 4
FACULTY
OFFICE 5
205
128 SF
206
128 SF
207
128 SF
208
246 SF
S4
S4
S4
8' $ 2"
E8
A5
A312
6' $ 3"
A453
S3
S4
S4
S4
S4
S4
T
T
T
T
S4
1
1
1
203
204
1
1
S2
211
1
1
205
206
1
1
1
212
213
1 TOILET
1
S2R1
FEC
3A
1
PH
S19 WORKROOM
1' $ 3"
1
T
1
ST3
215
51 SF
S2R1
1
FACULTY
OFFICE 7
3A
1
S6
1
2' $ 9 1/8"
211
PH
ST4R1 S2R1
5
1
ST3
201
577 SF
ST3R1
4
226
3
215
ST3R1
1
S2R1 S4R1 PH 201
S4R1 3A S6
1
DATA
A8
ELEV 1
J4
T
J8
S2R1
Connect all pig tails to building outlets.
Provide and install even amount of data and
outlets at each system furniture.
For offices, provide and install wire
managements, Neat Tech from
Humanscale as indicated in Red
line.
Note: Contractor field verify all location of existing power
outlet, data, and desks.
A455
T
S4R1
210
148 SF
1
FEC
E8
A454
ST3
210
MECH
209
137 SF
S4
S18
213
111 SF
HALLWAY
S4R1
FACULTY
OFFICE 6
1
209
214
H2
S2R1
1
1
S17
A4
A321
ST3
1
S4R1
1
208
6
F2 XA321A J2
STORAGE
S2R1
S4R1
1
207
1
212
192 SF
S15
214
60 SF
L2
T
ST3R1
202
195 SF
202
1
HALLWAY
T
ADMIN
S6
S16
218
79 SF
E6
A524
Item 8 SKA-02