PROJECT:ITEM NO.: CONTROL CENTER MODEL MS SINGLE DIRECTION SPECIFICATIONS •Single direction only • Push button ON/OFF switch • High impact polycarbonate construction • NEMA 4 • Magnetic starter/provides automatic shut-off in case of power interruption • Operates on line voltage VOLTAGE/PHASE AVAILABILITY Model Phase Disposer Models 1 Ph SS-100 to SS-200 MS-8208-240V, 50/60 Hz 1 Ph SS-100 to SS-200 MS-9208-240V, 50/60 Hz 3 Ph SS-100 to SS-1000 MS-10380-460V, 50/60 Hz 3 Ph SS-100 to SS-1000 MS-7 Voltage/Hz 120V, 50/60 Hz ON-SITE YEAR RECOMMENDED INSTALLATION PARTS & L ABOR WARR ANT Y DIMENSIONS 4-7/8” (123.8 mm) 4-1/4” (108.0 mm) 4” (101.6 mm) 4-7/8” (123.8 mm) 4-1/4” (108.0 mm) 4-1/2” (114.3 mm) NOTE: Use a #8 screw to mount control. A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com. 4700 21st STREET RACINE, WI 53406 TEL: 800-845-8345 FAX: 262 554-3620 www.insinkerator.com/foodservice InSinkErator is a business unit of Emerson Electric Co. The Emerson logo is a trademark and a service mark of Emerson Electric Co. InSinkErator ©2016 Printed in USA Form No. F452-16A-83-85 PROJECT:ITEM NO.: CONTROL CENTER MODEL MRS 3-BUTTON • MANUAL REVERSE SPECIFICATIONS • 3-button switch with FWD/STOP/REV • Stainless steel construction • NEMA 4 •Manual reverse allows increased cutting element life and reduces jams •Magnetic starter/provides automatic shut-off in case of power interruption • Operates on line voltage VOLTAGE/PHASE AVAILABILITY Model Phase Disposer Models MRS-14 120V, 50/60 Hz Voltage/Hz 1 Ph SS-100 to SS-200 MRS-15 208-240V, 50/60 Hz 1 Ph SS-100 to SS-200 MRS-16 208-240V, 50/60 Hz 3 Ph SS-100 to SS-1000 MRS-17 380-460V, 50/60 Hz 3 Ph SS-100 to SS-1000 ON-SITE YEAR RECOMMENDED INSTALLATION PARTS & L ABOR WARR ANT Y DIMENSIONS 6-3/4" (171.5 mm) 4-1/2" (114.3 mm) 5-1/4" (133.4 mm) 1-1/2" (38.1 mm) 8-1/4" (209.55 mm) 8-3/4" (222.25 mm) 5-7/8" (149.2 mm) NOTE: The MRS control center should be mounted 1-1/2" (38.1 mm) back from the front surface of the table. A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com. 4700 21st STREET RACINE, WI 53406 TEL: 800-845-8345 FAX: 262 554-3620 www.insinkerator.com/foodservice InSinkErator is a business unit of Emerson Electric Co. The Emerson logo is a trademark and a service mark of Emerson Electric Co. InSinkErator ©2016 Printed in USA Form No. F453-16A-83-85 PROJECT: ITEM NO.: ELECTRICAL CONTROLS SWITCHES Manual Switch - MS • Push button ON/OFF switch • High impact polycarbonate construction • NEMA 4 - water tight enclosure • Single direction only • Magnetic starter/provides automatic shut-off in case of power interruption • Operates on line voltage Manual Reverse Switch - MRS • 3 - Button switch with FWD/STOP/REV • Stainless steel construction • NEMA 4 - water tight enclosure • Manual reverse allows increased cutting element life and reduces jams • Magnetic starter/provides automatic shut-off in case of power interruption • Operates on line voltage • CUL approved switch Low Voltage Switch - MSLV • Push button ON/OFF switch • Stainless steel construction • NEMA 4 water tight enclosure • Single direction only • Line disconnect on front panel • Magnetic starter/provides automatic shut-off in case of power interruption • Low voltage (24 volt) control circuit ENCLOSURE DIMENSIONS ON REVERSE SIDE 4700 21st STREET RACINE, WI 53406-5093 TEL: 800-558-5712 [Commercial Products] FAX: 262-554-3620 www.insinkerator.com In-Sink-Erator is a division of Emerson Electric Co. The Emerson logo is a trademark and a servicemark of Emerson Electric Co. © IN-SINK-ERATOR Printed in USA Form No. C187-04E-02-02 ENCLOSURE DIMENSIONS (Inches) 4” ” /8 47 MANUAL SWITCH – MS 4 7/8” 3/8” between centerlines 41 /2” (wit /4” hb 21 utto (wit hou 4” t bu t ns) 11/16” from edge to centerline ton s) #6 3/8” panhead self-tapping screws needed MANUAL REVERSE SWITCH – MRS ” /16 67 /2 41 om ” fr LOW VOLTAGE SWITCH – MSLV s ine terl cen mounting holes 5/16” in diameter 6" 1 /4" DIA. HOLE (4) 5 1/2" 10 1/4" 10 3/4" 7 15/16” 8 9/16” from centerlines 8 1/4" 6 1/4" /4” 63 51 /4” PROJECT:ITEM NO.: CONTROL CENTER MODEL CC-202 AUTOMATIC REVERSING ACTION • DOUBLES THE LIFE OF DISPOSER GRINDING ELEMENTS SPECIFICATIONS STAINLESS STEEL ENCLOSURE • NEMA 4 • Stainless steel construction • Easy to clean and keep clean AUTOMATIC REVERSING CONTROL • Reverses direction of motor at each startup • Increases cutting element life and reduces jams REVERSING DELAY • Disposer will not reverse while motor is in motion • Protects motor from burn out from operator misuse AUTOMATIC DROP OUT SYSTEM • If a power loss occurs, control will automatically disengage power lines • Disposer must be restarted VOLTAGE/PHASE AVAILABILITY Model Voltage/Hz ON-SITE Phase Disposer Models CC202D-5 120V, 50/60 Hz 1 Ph SS-100 to SS-200 CC202D-6 208-240V, 50/60 Hz 1 Ph SS-100 to SS-200 CC202D-7 208-240V, 50/60 Hz 3 Ph SS-100 to SS-1000 CC202D-8 380-460V, 50/60 Hz 3 Ph SS-100 to SS-1000 RECOMMENDED INSTALLATION YEAR PARTS & L ABOR WARR ANT Y DIMENSIONS 8-1/4" (209.6 mm) 6" (152.4 mm) 10-3/4" (273.1 mm) 10-1/4" (260.4 mm) 5-1/4" (133.4 mm) 5-7/8" (149.2 mm) NOTE: The CC-202 control center should be mounted 1-1/2" (38.1 mm) back from the front surface of the table. A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com. 4700 21st STREET RACINE, WI 53406 TEL: 800-845-8345 FAX: 262 554-3620 www.insinkerator.com/foodservice InSinkErator is a business unit of Emerson Electric Co. The Emerson logo is a trademark and a service mark of Emerson Electric Co. InSinkErator ©2016 Printed in USA Form No. F454-16A-83-85 PROJECT:ITEM NO.: CONTROL CENTER MODEL CC-101 WATER/ENERGY SAVING FEATURE • AUTOMATIC REVERSING ACTION SPECIFICATIONS STAINLESS STEEL ENCLOSURE • NEMA 4 • Stainless steel construction • Easy to clean and keep clean AUTOMATIC REVERSING CONTROL • Reverses direction of motor at each startup • Increases cutting element life and reduces jams REVERSING DELAY • Disposer will not reverse while motor is in motion • Protects motor from burn out from operator misuse AUTOMATIC DROP OUT SYSTEM • If a power loss occurs, control will automatically disengage power lines • Disposer must be restarted DISCONNECT SWITCH • Disconnects electrical power beyond switch for service • Interlock with front cover SOLID STATE CONTROL • Operates on 24V SOLID STATE CONTROL CIRCUIT •Printed circuit board with control diagnostic/function lights, delay timers and timed run pin and reversing control POST WATER FLUSH • Adjustable timer allows water to run automatically for up to 10 minutes, flushing disposer and drain lines after disposer is shut off TIMED RUN OR CONTINUOUS RUN • Selected at your discretion, simply by moving the plug-in in on the printed circuit board •Timed run shuts off disposer automatically after 10 minutes • Can be shut off manually any time SOLENOID VALVE • Packed unattached inside control center carton • Ensures that water is flowing into disposer while disposer is operating ON-SITE PARTS & L ABOR YEAR WARR ANT Y DIMENSIONS 9-7/8" (250.8 mm) 8-1/4" (209.6 mm) 1" (25.4 mm) 15-3/4" (400.1 mm) 15-1/8" (384.2 mm) 14" (355.6 mm) VOLTAGE/PHASE AVAILABILITY Model Voltage/Hz Phase Disposer Models CC101K-5 120V, 50/60 Hz 1 Ph SS-100 to SS-200 CC101K-6 208-240V, 50/60 Hz 1 Ph SS-100 to SS-200 CC101K-7 208-240V, 50/60 Hz 3 Ph SS-100 to SS-1000 CC101K-8 380-460V, 50/60 Hz 3 Ph SS-100 to SS-1000 5-5/16" (134.9 mm) 6-3/4" (171.5 mm) A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com. 4700 21st STREET RACINE, WI 53406 TEL: 800-845-8345 FAX: 262 554-3620 www.insinkerator.com/foodservice InSinkErator is a business unit of Emerson Electric Co. The Emerson logo is a trademark and a service mark of Emerson Electric Co. InSinkErator ©2016 Printed in USA Form No. F455-16A-83-85 RECOMMENDED INSTALLATION NOTE: The CC-101 control center should be mounted 1-1/2" (38.1 mm) back from the front surface of the table. PROJECT:ITEM NO.: CONTROL CENTER MODEL AS-101 INDUSTRY EXCLUSIVE! WATER SAVING CONTROL CENTER WATER SAVING FEATURES • The AquaSaver® control center provides an on-demand water-saving system for InSinkErator foodservice disposers • The AS-101 control center senses the load of the disposer and regulates the amount of water necessary for grinding and non-grinding situations SPECIFICATIONS STAINLESS STEEL ENCLOSURE • NEMA 4 • Stainless steel construction • Easy to clean and keep clean AUTOMATIC REVERSING CONTROL • Reverses direction of motor at each startup • Increases cutting element life and reduces jams REVERSING DELAY • Disposer will not reverse while motor is in motion • Protects motor from burn out from operator misuse AUTOMATIC DROP OUT SYSTEM • If a power loss occurs, control will automatically disengage power lines • Disposer must be restarted DISCONNECT SWITCH • Disconnects electrical power beyond switch for service • Interlock with front cover SOLID STATE CONTROL • Operates on 24V SOLID STATE CONTROL CIRCUIT • Printed circuit board with control diagnostic/function lights, delay timers and timed run pin and reversing control POST WATER FLUSH • Adjustable timer allows water to run automatically for up to 10 minutes, flushing disposer and drain lines after disposer is shut off TIMED RUN OR CONTINUOUS RUN • Selected at your discretion, simply by moving the plug-in pin on the printed circuit board • Timed run shuts off disposer automatically after 10 minutes • Can be shut off manually any time SOLENOID VALVE/FLOW CONTROL VALVE • Two 24V solenoid valves included • 1 GPM (3.8 LPM) and 7 GPM (26.5 LPM) flow control valves included ON-SITE * YEAR PARTS & L ABOR WARR ANT Y *Standard warranty is 1-year from date of installation. New AquaSaver® control system installations that include a new disposer and new AS-101 control center are eligible for a 3-year warranty on the entire system, including disposer. DIMENSIONS 9-7/8” (250.8 mm) 8-1/4” (209.6 mm) 1” (25.4 mm) 15-3/4” (400.1 mm) 15-1/8” (384.2 mm) 14” (355.6 mm) 5-5/16” (134.9 mm) 6-3/4” (171.5 mm) VOLTAGE/PHASE AVAILABILITY Model Voltage/Hz Phase Disposer Models AS101K-5 120V, 50/60 Hz 1 Ph SS-100 to SS-200 AS101K-6 208-240V, 50/60 Hz 1 Ph SS-100 to SS-200 AS101K-7 208-240V, 50/60 Hz 3 Ph SS-100 to SS-1000 AS101K-8 380-460V, 50/60 Hz 3 Ph SS-100 to SS-1000 4700 21st STREET RACINE, WI 53406 TEL: 800-845-8345 FAX: 262 554-3620 www.insinkerator.com/foodservice InSinkErator is a business unit of Emerson Electric Co. A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com. The Emerson logo is a trademark and a service mark of Emerson Electric Co. InSinkErator ©2016 Printed in USA Form No. F456-16A-83-85 TYPICAL TROUGH MOUNT APPLICATION TYPICAL BOWL MOUNT APPLICATION NOTE: The AquaSaver® control center should be mounted 1-1/2" (38.1 mm) back from the front surface of the table. AS-101 FEATURES Automatic Reversing Magnetic Contactors AquaSaver® Sensor Module Post Water Flush Transformer Timed Run or Continuous Run Solid State Control Circuit Line Disconnect Switch Stainless Steel Enclosure