eSure™ Rectifier DC Power for Business-Critical Continuity™ R48-4000e eSure™ Rectifier -48 V DC, 4000 W Features and Benefits Optimized depth-reduced footprint allows installation in short-depth racks and cabinets DSP (Digital Signaling Processor)means fewer components, optimized operation and active load sharing for increased reliability Description The eSure™ R48-4000e rectifier converts standard AC supply voltages into stable nominal-48V DC voltage adjustable to the needs of the application. The R484000e is a constant power rectifier designed with the latest patented switchmode technology using DSP (Digital Signaling Processor) functionality for efficient operation. For a higher load capacity, rectifiers can be connected in parallel and intelligent control can be added with the help of a separate controller. High efficiency, 95.3%-reduces power consumption for lower operating costs Hot pluggable-facilitates future extensions Wide input voltage range-operates in the most demanding environments where input voltage changes Wide temperature operating range (-40°C / -40 °F to +75°C / 167°F) -meets the harshest climatic environment requirements R48-4000e eSure™ Rectifier R48-4000e Technical Specifications, R48-4000e DC Output Output Voltage, Adjustment Range Output Power Output Power, Derated for Input Voltage Output Current Output Current limit set Point Psophometric noise (system) Temperature Derating Output power vs. Temperature at 264V ≥Vin ≥184 Vac % of output power 184 to 250 V AC 85 to 300 V AC 45 to 65 Hz 22A 0.99 <5% from 50 to 100% of rated load -42 to -58 V DC 4000W@Vout >48VDC See Diagram 83.3A 6.9 to 83.3A 95.3% peak <2 mV at 70% max load See diagram 120 100 80 60 40 20 0 -40 Temperature Range, Storage -40 to +75°C, -40 to +167°F Relative Humidity Altitude EMC Safety 0 to 95% 2000 m, 6560 ft at full power ETSI EN 300 386 class A IEC 60950, EN 60950 Mechanics Dimensions (H×W×D) Weight 132×85.3×293mm / 5.2×3.36×11.5 inches 3.5kg / 7.7Ibs Other parts Controller Units Ordering information Description 80 100 60 40 20 50 100 150 200 250 Input voltage (Vac) 300 400 60 50 40 30 20 10 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Output current(A) Efficiency Curve 98 96 94 92 90 88 86 84 Product Code 1R484000eXXX www.emersonnetworkpower.com www.emersonnetworkpower.com/energysystems 60 80 0 See separate ACU+ and SCU+ datasheets Emerson Network Power. The global leader in enabling Business-Critical Continuity™. 40 Output voltage v.s. Output current at max. Power 4000W Output Voltaqe(V) -40 to +75°C, -40 to +167°F 20 100 0 Alarm and status reported via CAN bus to system Controller Green LED: Normal Operation Yellow LED: Alarm Red LED: Failure Flashing Red LED: Fan Failure Environmental Temperature Range, Operating 0 Temperature (°C) 120 Control and Monitoring Visual Indications -20 Output power vs. Input voltage and Vo >48V at Temp≤50°C % of output power AC Input Input Voltage, Nominal Input Voltage, Permitted Variation Line Frequency Max Input Current Power Factor THD (Total Harmonic Distortion) 0 1 20 30 40 50 60 70 80 90 100 Load (% of rated load) AC Power Embedded Power Precision Cooling Connectivity Infrastructure Management & Monitoring Racks & Integrated Cabinets DC Power Outside Plant Services Embedded Computing Power Switching & Controls Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2014 Emerson Electric Co. 2014.11