4. Installation (2) S1:Continuous light or Flashing with Buzzer INSTALLATION MANUAL Model : LME - S□,Q□ Thank you for specifying the PATLITE Signal Tower for your application. Please read these instructions carefully before you perform installation, maintenance and repair. Store this manual carefully for easy reference. If you have any questions about this product, please contact PATLITE Corporation. [Product explanation] This product is the unit which can be stacked on LME/LMS. LED Red Red LED Amber Orange LED Green Green LED Blue Blue LED White White Buzzer 1 Purple Buzzer 2 Skyblue Multi color LED unit Head cover Center screw Multi color LED unit Gray wire Yellow wire Base body Caution 1. To operate this product safely please observe the followings Warning ● Make sure the power is off before wiring, repairing, or replacing parts to avoid a short-circuit, electric shock, or burn. ● Do not use this product with the lens damaged or removed, or without the head cover in order to avoid an electric shock. ● When the installation of this product requires the construction, please ask to specialist. Electric shock, fire or fall may occur. ● When you use this product for security purpose, routine inspection must be done. Just in case of emergency we recommend you to use this product together with other security product. Caution ● For the replacement parts such as LED unit or fuse etc. Be sure to use parts specified on this manual. ● Make sure to connect fuse to power source as shown in wiring example. ● Do not reform with the unit of other product, as it may be disordered. LME - S □ ■Installationable model LME model LMS model ■Combinations 3 colors multi LED unit S1,S4,S7 4 colors multi LED unit Q1,Q2,Q4 LED color Mark S1 Red・Amber・Green S4 Red・Green・Blue S7 Amber・Green・Blue LED color Mark Q1 Red・Amber・Green・Blue Q2 Red・Amber・Green・White Q4 Amber・Green・Blue・White 3. Parts name and dimensions For 3 Lights Power supply wires For 2 Lights For 1 Light Caution ● Make sure power is turned off before wiring or for repair to avoid electric shock. ● This unit is specialized only for LME/LMS model. ● Do not use the unit only. A short circuit may damage internal circuits or cause an electric shock. ● Be careful fot the direction of the unit when stacking. ● Be careful of the drop of the unit or the turn over etc. when installing or stacking at height or unstable place. ● Be sure to fasten the head cover after stacking on the unit. The tightening torque is about 0.68N・m. ● Longer screw may damage the parts inside. ● This unit can be stacked up to 5 high. However, another center screw is necessory for 4 or 5 high stack. They are supplied as optional parts. ※ Please do not do any other usage except one described here. Specifications are subject to change without notice. 5. Wiring procedure LED color Red Amber Green Blue White ● Each color of the lead wire is matching with each color of the LED that illustrated on the left. ● After stacking of the unit, please refer to the following wiring example when wiring. Wire color Red wire Orange wire Green wire Blue wire White wire Wiring example (1) S1:Continuous light 55 100 140 External contact for Continuous Taping ■In case of stacking on the 100/220V AC model LED Red Red LED Amber Orange LED Green Green LED Blue Blue LED White White External contact for Continuous Taping Yellow wire 40.5 Senter screw:M4 Accessories Continuous or Flashing Yellow wire External contact fuse (1A) 1A Yellow wire Power supply Power supply Gray wire Black wire External contact fuse (1A) Power supply 24V DC ● You may connect NPN type for the transistor connecting. ● Change the external point of the wiring example to transistor contact according to the left figure. Fuse Model Transistor(NPN) Withstand voltage Vc≧35V Current capacity Ic≧100mA(LED unit) Leak current IL≦0.1mA ※ As for the contact point capacity about the buzzer, please follow the instruction manual which is in the box of the body. 6. Specifications Model Rated current LME-S□ Red・Amber :50mA Green・Blue :31.5mA LME-Q□ Caution LED Red Red LED Amber Orange LED Green Green LED Blue Blue LED White White φ60 External contact fuse Black wire (1A) I/O unit Each lead wires ■In case of stacking on the 24V AC/DC model Multi color unit Here comes snap Here comes snap Lead wires [Wire color] ●4 colors multi LED unit [Standard model] ●3 colors multi LED unit [Standard model] Power supply (3) Transistor drive example of 24V DC ● Make sure the power is OFF before install the wiring. A short circuit may damage internal circuits or cause an electric shock. ● Wiring : First, stack the unit on the base body, then wire the base body. ※ Be sure to connect power supply(Yellow) wire with the + side when stacking this unit on the product of 24V type. ● When using multiple LED units of the same color, make the contact capacity equal to the number of same color LED units multiplied by the contact capacity for 1 light. (This is because LED units of the same color light up for one signal line.) ● As for the detailed information, please read the instruction manual carefully which is packed with base body. ● Please do not turned on at the simultaneous for the LED line in a Multi-Color LED Unit. 2. Model No.configuration Brown wire Yellow wire Gray wire ※ As for the other unit, please wire according to the above wiring example and the wiring color table. In order to prevent any damage to the user and other personnel or to assets, note the following: Indicates an imminently dangerous condition: failure to follow the instructions may lead to death or serious injury. Indicates a potentially dangerous condition: failure to follow the instructions may lead to slight injury or property damage. External contact fuse External contact for Flashing LED Red Red LED Amber Orange LED Green Green LED Blue Blue LED White White Buzzer 1 Purple Buzzer 2 Skyblue (1A) NOTES TO BE OBSERVED FOR SAFE OPERATION Warning Taping Brown wire Base body ■The indications for warning are divided into the following classes according to the degree of danger or damage incurred when the warning is not taken into consideration and the product is not correctly used. External contact for Flashing External contact for Continuous Multi-color LED unit ■In case of stacking on the 100/220V AC model External contact for Continuous ■In case of stacking on the 24V AC/DC model ① Loosen the senter screw, then remove the head cover. ② Fit two snaps into the holes for correct positioning, then stack the unit on the base body. ※ Each LED unit is secured by 2 small snaps of different sizes to ensure that the module is assembled correctly. ③ Put the head cover, then fasten with the center screw. ※ Choose the center screw of the length which is suitable for the light style. Accessories Red・Amber :30mA Green・Blue・White:31.3mA Mass Base body model 0.05kg LME series LMS series Center screw:1・2・3 high 1 each Caution ●PATLITE Corporation disclaims all liability for any malfunction or damage occurring as a result of handling contrary to the instructions, cautions and warnings mentioned in this manual. ●Specifications may change without notice due to continual product improvement.